SCIENTIFIC INSTRUMENTS AN ISO 9001:2015 COMPANY WENSAR R Head Office WhatsApp : 7299924410 & [email protected] ION SELECTIVE ELECTRODES Br Bromide Calcium Chloride Fluoride Iodide Sodium Nitrate Silver Sulfide + Ca + CI F I + Na NO 3 + Ag S – – NH 3 Ammonia Ion / pH meter 5 point calibration IFS Standard Solution 1000 ppm ISAB CATALOGUE 2016-17 Exclusive

Transcript of AN ISO 9001:2015 COMPANY Exclusive SCIENTIFIC … S_catlog_46.pdf · When a suitable sensing...

SCIENTIFIC INSTRUMENTSAN ISO 9001:2015 COMPANY

WENSARR

Head Office WhatsApp : 7299924410 & [email protected]

ION SELECTIVE ELECTRODES

–Br Bromide

Calcium

Chloride

Fluoride

Iodide

Sodium

Nitrate

Silver

Sulfide

+Ca+

–CI

–F

–I

+Na

–NO3

+Ag

S– –

−NH 3 Ammonia

Ion / pH meter 5 point calibration

IFS

Standard Solution1000 ppm

ISAB

CATALOGUE

2016-17

Exclusive

SCIENTIFIC INSTRUMENTSAN ISO 9001:2015 COMPANY

WENSARR

ISEs 2016-17

2

Our Valued Customers

BPL

S E R V I C E S L T D

Associate Company of Ion Exchange (India) Ltd.

ION EXCHANGE

Head Office WhatsApp : 7299924410 & [email protected]

SCIENTIFIC INSTRUMENTSAN ISO 9001:2015 COMPANY

WENSARR

3 Head Office WhatsApp : 7299924410 & [email protected]

ISEs 2016-17

The concentration of Ions and gases in solution may be determined using ion selective electrodes.

When a suitable sensing electrode is immersed in a solution containing ions or gases, an electrical potential may

develop at the electrode surface due to a selective spontaneous reaction. The magnitude of this potential varies

with the concentration of the selected ion or gas.

ISEs are responsive to concentration of particular ions in the test liquid and are variable-potential electrodes.

When measurements are made using an ion meter, by calibrating with various standard solutions, direct readings

of the concentration of the ion can be taken.

Slope of the electrode depends on the temperature therfore measurements must be taken at a fixed temperature.

INTRODUCTION

No Reference electrode needed

Ideal for unskilled operatives

Our ISEs are compatible with other make Ion / pH meter

Direct measurement of Ionic concentration

Standard supply with ISAB & Calibration Solutions

Solid state sensors

Refillable Type

Virtually unbreakable

Fast response no maintenance

No membranes or replacement module

Ion Selective Electrodes Combination

are as combination electrodes complete with reference electrode.

These electrodes incorporate a solid sensing surface made of compressed silver halides, or solid crystalline material.

A solid state electrode develops a voltage due to ion-exchange occurring between the sample and the inorganic

membrane. An equilibrium mechanism occurs due to the very limited solubility of the membrane material in the sample.

re combination electrodes that detect dissolved gases in a solution. No external reference is required for these

electrodes. The sensing element is separated from the sample solution by a gas permeable membrane.

A gas sensor works due to the partial pressure of the measured gas in solution. The dissolved gas in the sample diffuses

into the membrane and changes the pH in a thin film of unbuffered electrolyte on the surface of the internal pH sensor.

Diffusion continues until the partial pressure of the sample and the thin film is the same. The pH change is proportional to

the dissolved gas in the sample.

SOLID STATE ELECTRODES

GAS SENSORS

a

It is sufficient to store the electrode in a standard solution during short measuring intervals. In order not to strain

the membrane unnecessary, the electrode should be stored dry if it is not used for several days. After the dry storage

put into standard solution for 3 - 4 hours for new measurements. Contaminations should be removed with a wet

paper towel, don’t use organic solvents like acetone.

STORAGE AND CLEANING

SCIENTIFIC INSTRUMENTSAN ISO 9001:2015 COMPANY

WENSARR

Head Office WhatsApp : 7299924410 & [email protected]

Part No ISE-23

Ion Type Sodium +Symbol Na

M M

oC

+ +Li , K

Make LABMAN

Refillable or Gel (Sealed) Refillable -1 -6 Concentration range 10 to 10

Limits (ppm) 2300 ppm to 0.02 ppm

pH Range above 10

Temperature Range 5 to 60

Electrode Resistance less than 1 megohms

Reproducibility + 2%

Membrane Solid State

Material Glass Electrode

Slope +54 to + 60 mV

Cable Length 1 meter

Connector BNC

Main Interferences

Dimension Φ 12 x 165 mm

Accessories Sodium Standard Solution & ISAB ( 500ml each )

Ion Selective Electrodes Combination

Part No ISE-80

Ion Type Bromide -Symbol Br

Make LABMAN

Refillable or Gel (Sealed) Refillable

M M

oC

- -- - I , S , CN

-1 -6 Concentration range 10 to 5 x10

Limits (ppm) 7990 ppm to 0.4 ppm

pH Range 2 to 12 pH

Temperature Range 5 to 60

Electrode Resistance less than 1 megohms

Reproducibility + 2%

Membrane Solid State

Material Plastic

Slope -54 to -59 mV

Cable Length 1 meter

Connector BNC

Main Interferences

Dimension Φ 12 x 165 mm

Accessories Bromide Standard Solution & ISAB ( 500ml each ) Spec

ificat

ions

are

sub

ject

to c

hang

e wi

thou

t not

ice.

Application : Steam condensate, meats, fish, diary, fruit juices, fermentation, b ground/sea water, soils, ody fluids,

Sodium

So

diu

m

Co

mb

ina

tio

n E

lec

tro

de

Bro

mid

e

Co

mb

ina

tio

n E

lec

tro

de

Bromide

Application : Biological fluids, soil, plants foots,effluents,

4

ISEs 2016-17

SCIENTIFIC INSTRUMENTSAN ISO 9001:2015 COMPANY

WENSARR

Head Office WhatsApp : 7299924410 & [email protected]

Part No ISE-17

Ion Type Ammonia −Symbol NH3

-1 -6 10 M to 5x10 M

1700 ppm to

o5 to 45 C

less than 1000 megohms

Hydrazine, Amines

Make LABMAN

Refillable or Gel (Sealed) Refillable

Concentration range

Limits (ppm) 0.1 ppm

pH Range above 11

Temperature Range

Electrode Resistance

Reproducibility + 2%

Membrane Gas Sensing

Material Plastic

Slope -54 to -60 mV

Cable Length Coaxial 1 meter

Connector BNC

Main Interferences

Dimension Φ 12 x 165 mm

Accessories Ammonia Standard Solution & ISAB ( 500ml each )

Ion Selective Electrodes Combination

Part No ISE-127

Iodide

-

-1 -7 10 M to 5x10 M

12700 ppm to 0.07 ppm

o

++ - Hg , CN

Ion Type

Symbol I

Make LABMAN

Refillable or Gel (Sealed) Refillable

C

Concentration range

Limits (ppm)

pH Range 2 - 12 pH

Temperature Range 5 - 60

Electrode Resistance less than 1000 megohms

Reproducibility + 2%

Membrane Solid State

Material Plastic

Slope -54 to -60 mV

Cable Length 1 meter

Connector BNC

Main Interferences

Dimension Φ 12 x 165 mm

Accessories Iodide Standard Solution & ISAB ( 500 ml each ) Spec

ificat

ions

are

sub

ject

to c

hang

e wi

thou

t not

ice.

Application : Sewage effluent, boiler water, fish tanks,Stack gases, sea water, biologicalsamples, fertilizers,

Ammonia

Am

mo

nia

C

om

bin

ati

on

Ele

ctr

od

eIo

did

e

Co

mb

ina

tio

n E

lec

tro

de

Iodide

Application : Milk, Feeds, Plants and Pharmaceuticals

5

ISEs 2016-17

SCIENTIFIC INSTRUMENTSAN ISO 9001:2015 COMPANY

WENSARR

Head Office WhatsApp : 7299924410 & [email protected]

Part No ISE-19

Ion Type Fluoride −Symbol F

-1 -6 10 M to 10 M

5 to 7 pHo

5 to 60 C

-OH

Make LABMAN

Refillable or Gel (Sealed) Refillable

Concentration range

Limits (ppm) 1900 ppm to 0.02 ppm

pH Range

Temperature Range

Electrode Resistance

Reproducibility + 2%

Membrane Solid State

Material Plastic

Slope -54 to -60 mV

Cable Length 1 meter

Connector BNC

Main Interferences

Dimension Φ 12 x 165 mm

Accessories Fluoride Standard Solution & TISAB ( 500ml each )

less than 1000 megohms

Ion Selective Electrodes Combination

ISE-62

Ion Type Nitrate −Symbol NO 3

Refillable or Gel (Sealed) Refillable -1 -5

10 M to 10 M

6200 ppm to 0.62 ppm

2.5 to 11

oC

1 to 4 megohms

-54 to -60 mV

− − − ClO , I , BF44

Part No.

Make LABMAN

Concentration range

Limits (ppm)

pH Range pH

Temperature Range 5 to 60

Electrode Resistance

Reproducibility 4%

Membrane Solid State

Material Plastic

Slope

Cable Length 1 meter

Connector BNC

MainInterferences

Dimension 12 x 165 mm

Accessories Nitrate Standard Solution & ISAB ( 500 ml each )

+

Φ

Spec

ificat

ions

are

sub

ject

to c

hang

e wi

thou

t not

ice.

Application : Drinking Water, Wastewater and naturalwaters, stack gases, sea water, minerals, soils, foods, biological, fluids, toothpaste.

Fluoride

Flu

ori

de

C

om

bin

ati

on

Ele

ctr

od

eN

itra

te

Co

mb

ina

tio

n E

lec

tro

de

Nitrate

Application : Pollution testing, foods, pharmaceuticals,explosives, fertilizers, plants, meants,pickling baths

6

ISEs 2016-17

Use Plastic Containers

only for analysis

SCIENTIFIC INSTRUMENTSAN ISO 9001:2015 COMPANY

WENSARR

Head Office WhatsApp : 7299924410 & [email protected]

Part No ISE-35

Ion Type Chloride −Symbol Cl

-1 -110 M to 5x10 M

3550 ppm to 1.8 ppm

2 to 12pHo5 to 60 C

less than 1 megohms

− − − −−I , Br , CN , S

Make LABMAN

Refillable or Gel (Sealed) Refillable

Concentration range

Limits (ppm)

pH Range

Temperature Range

Electrode Resistance

Reproducibility + 2%

Membrane Solid State

Material Plastic

Slope -54 to -60 mV

Cable Length 1 meter

Connector BNC

Main Interferences

Dimension Φ 12 x 165 mm

Accessories Chloride Standard Solution & ISAB ( 500 ml each )

Ion Selective Electrodes Combination

Part No ISE-40

Ion Type ++Symbol

Refillable or Gel (Sealed) Refillable -1 -5 M to M

oC

Calcium

Ca

10 10

4000 ppm to 0.4 ppm

2.5 to 11 pH

1 to 4 megohms

25 to +30 mV

Make LABMAN

Concentration range

Limits (ppm)

pH Range

Temperature Range 5 to 60

Electrode Resistance

Reproducibility + 4%

Membrane Solid State

Material Plastic

Slope +

Cable Length 1 meter

Connector BNC

Main Interferences

Dimension Φ 12 x 165 mm

Accessories Calcium Standard Solution & ISAB ( 500ml each )

++ ++ ++ ++Fe 、Pb 、Zn 、Mn

Spec

ificat

ions

are

sub

ject

to c

hang

e wi

thou

t not

ice.

Application : Water / waste water, soil, diary meals,tomato, vegetable products

ChlorideCh

lori

de

C

om

bin

ati

on

Ele

ctr

od

eC

alc

ium

C

om

bin

ati

on

Ele

ctr

od

e

Calcium

Application : Foods beverages, soil, pharmaceuticalsexplosives, fertilizers, plants.

7

ISEs 2016-17

SCIENTIFIC INSTRUMENTSAN ISO 9001:2015 COMPANY

WENSARR

Head Office WhatsApp : 7299924410 & [email protected]

Part No ISE-107

Ion Type Silver

+Symbol Ag

Make LABMAN

2 to 12 pHo

5 to 60 C

-- ++ , S Hg

Refillable o r Gel (Sealed) Refillable

Concentration range

pH Range

Temperature Range

Electrode Resistance

Reproducibility + 2%

Membrane Solid State

Material Plastic

Slope + 54 to + 60 mV

Cable Length 1 meter

Connector BNC

Main Interferences

Dimension Φ 12 x 165 mm

d Solution & ISAB ( 500 ml each )

-1 -7 10 M to 3x 10 M

Limits (ppm) 10790 ppm t o 0.03 ppm

less than 1 megohms

Accessories Silver Standar

Ion Selective Electrodes Combination

Part No ISE-32

Ion Type Sulfide

--Symbol S

Refillable or Gel (Sealed) Refillable -1 -7

10 M to 3x10 M

3200 ppm to 0.01 ppm

2 to 12 oC

to -30 mV

+++ Ag Hg

Make LABMAN

Concentration range

Limits (ppm)

pH Range pH

Temperature Range 5 to 60

Electrode Resistance

Reproducibility + 4%

Membrane Solid State

Material Plastic

Slope -25

Cable Length 1 meter

Connector BNC

Main Interferences

Dimension Φ 12 x 165 mm

Accessories Sulfide Standard Solution & ISAB ( 500 ml each )

less than 1 megohmsSp

ecific

atio

ns a

re s

ubje

ct to

cha

nge

with

out n

otice

.

Application : Sewage. effluent, soils, sediments, plating baths, pulping, liquors, photographic fixing solution

Silver

Sil

ve

r C

om

bin

ati

on

Ele

ctr

od

eS

ulf

ide

C

om

bin

ati

on

Ele

ctr

od

e

Sulfide

Application : Sewage. effluent, soils, sediments, plating baths, pulping, liquors, photographic fixing solution

8

ISEs 2016-17

During the pH mode, Up to 5 points push-button calibration with auto-buffer recognition

Selectable pH buffer standards and temperature units.

Automatically calculates and displays electrode slope after calibration.

During the ion mode, 2 to 5 points push-button calibration from low to high concentrations

Direct readout ion concentration simplifies the elaborate measurement process.

Automatic Temperature Compensation (ATC) ensures highly accurate measurements over the entire range.

Automatic endpoint function freezes the stable measured values for easy reading and recording data.

Calibration due reminder prompts you to calibrate the meter regularly.

Help message as a operational guide to helps you understand how to use meter.

Setup menu lets user customizes buffer standards, calibration points, stability conditions, resolution,

measurement units, date and time to meet measurement requirements.

Reset function can resumes all settings to factory default values.

Built-in real-time clock stamps stored data to meets GLP standards.

Stored data can be transferred into computer via USB communication interface.

Salient Features

SCIENTIFIC INSTRUMENTSAN ISO 9001:2008 COMPANY

WENSARR

9 Head Office WhatsApp : 7299924410 & [email protected]

ISEs 2016-17

LMION-40

Benchtop ION/pH/mV/°C Meter

STANDARD ACCESSORIES : Temperature Probe, Electrode Stand, Power Adaptor Instruction Manual.

LMION - 40 is a high accuracy meter, used for measuring the ION concentration, ORP and pH values of liquids.

The meter widely used in environmental studies, chemical labs, swimming pools etc.

( 5

Po

int

- C

alib

rati

on

fo

r p

H &

Ion

)

Model LMION-40

Make LABMAN

pH Range   -2.000 ~ 20.000pH

pH ±0.002pH    

Resolution   0.001,0.01,0.1pH ( Selectable )

Calibration Points up to 5 points

Ion Concentration Range 0.001~19999 ppm,mg/L,mol/L (Selectable Depending on meas. Range of Ion Selective Electrode)

Ion Concentration Accuracy ±0.5% Full Scale ( Monovalent),±1% Full Scale (Divalent)

Ion Resolution 0.001, 0.01, 0.1, 1

Calibration Points up to 5 points

mV Range ±1999.9 mV

±0.2mV

Resolution  0.1/1mV, Selectable

Calibration points 1 point (Only for Relative mV mode)

Temperature Range  0~105˚C, 32~221˚F

±0.5˚C,±0.9˚F

Resolution 0.1

Calibration Points Ion / pH : Up to 5 Points

pH Buffer Groups USA (pH1.68,4.01,7.00,10.01,12.45), NIST (pH1.68,4.01,6.86,9.18,12.45), DIN (pH1.09,4.65,6.79,9.23,12.7 OR User Define)

Memory 500 data sets with Date/Time stamping,

USB Communication interface.

Connector BNC

Selectable

Temperature Compensation   0~100˚C,32~212˚F,

Compensation Mode Automatic or Manual

Stability Conditions   Low or High, Selectable

Calibration due Reminder   1 to 31 days or Off

Power Supply  

Dimensions LxWxH (mm)

Weight   1.2kg

Accuracy

mV Accuracy

Accuracy

˚C,

Output

Hold Function

DC 5V adapters, using AC 220V / 50Hz,

210 × 188 × 60

Ion / pH Meter - 5 Point CalibrationSPECIFICATIONS

SCIENTIFIC INSTRUMENTSAN ISO 9001:2008 COMPANY

WENSARR

Head Office WhatsApp : 7299924410 & [email protected]

Spec

ifica

tions

are

sub

ject

to c

hang

e w

ithou

t not

ice.

pH & Ion Selective Electrodes Optional

pH

Ion

mV

Tem

pera

ture

Oth

ers

10

ISEs 2016-17

SCIENTIFIC INSTRUMENTSAN ISO 9001:2015 COMPANY

WENSARR

ISEs 2016-17

11

HPB Series - 1mg PGB 220 / 0.001gMoisture Balance HPB Series - 10 mg

Automatic Polarimeter Abbe Refractometer PCR Gradient Thermal Cycler

Probe Sonicator Ceramic Hotplate

Ice Maker

Rotational Viscometer

UV-VIS. Double Beam

Digital Ultrasonic Cleaner

Peltier / Sipper System pH Meter - 5 point Ion Meter & ISEs

UV-VIS Spectrophotometer

PGB 200 / 0.001g PGB 3010 / 6000

PGB 620 / 0.01g PGB 630 / 0.01g

20kg / 0.1gPGB 3110 & 6100

Crane Scle

6kg / 1g

Analytical Balance - 0.1mg

Ou

r ra

ng

e o

f W

eig

hin

g B

alan

ceO

ur

ran

ge

of

Sci

enti

fic

Inst

rum

ents

Spec

ifica

tions

sub

ject

to c

hang

e w

ithou

t not

ice.

WE

IGH

TS E1

E2

F1

F2

: 1mg to 200g READY STOCK )

: 1mg to 200g & Individual : 50g, 100g, 200g, 500g, 1kg, 2kg, 5kg, 10kg, 20kg

: 1mg to 200g & Individual : 50g, 100g, 200g, 500g, 1kg, 2kg, 5kg, 10kg, 20kg

: 1mg to 200g & Individual : 50g, 100g, 200g, 500g, 1kg, 2kg, 5kg, 10kg, 20kg

( E1 & E2 also always

WENSAR R

WENSAR R

WENSAR

PGB 610 / 0.01gGlass Windshield

PGB 600 / 0.01g 300g/ 0.01g

LABMAN

Digital Refractometer

Ice Flaker

Head Office WhatsApp : 7299924410 & [email protected]

SCIENTIFIC INSTRUMENTSAN ISO 9001:2015 COMPANY

WENSARR

ISEs 2016-17

[email protected]

www.wensar.com

www.labman.co.in

WhatsApp 7299924410

Online Reply

AHMEDABAD

BENGALURU

AMBALA

HYDERABAD

INDORE

No.342, Spectrum Shopping Centre,

3rd Floor,Salapouse Road , Nr. GPO,

Ahmedabad -380 001 . ( INDIA)

Phone : 079 – 25 50 05 01 & 30 25 10 22

M o b i l e N o . 9 5 5 8 8 0 4 3 7 2

2 9 6 8 / 2 4 , 1 s t M a i n

C - Block, Gayathri Nagar,

Bengaluru - 560 021. (INDIA)

:Phone 080 - 23 32 91 86

Mobi le No.9900013628

4313/1, First Floor, Science Market,

N e a r B . D . H i g h S c h o o l ,

Ambala Cantt - 133001 ( INDIA )

Phone No : 0171- 4008806 & 2634717

M o b i l e N o . 8 2 9 5 5 6 4 4 9 9

KOLKATA

167/B, Park St., Ground Floor,

Kolkata – 700 017.(INDIA)

P h o n e :

Mobile No. 88201 40895

0 8 2 2 9 9 6 3 0 2 0

MUMBAIDELHI

A-51 , Radhey puri Extension,

Near Nirankari Bhavan,

Delhi - 110 051 (INDIA )

Ph : 011 – 22 44 62 00 & 63 00

Mobi le No. 8826300443

402, Shahviri Premises Co-op Hsg. Soc.

37/41 R.S. Sapre Road , 4th Flr. Kalbadevi,

M u m b a i - 4 0 0 0 0 2 . ( I N D I A )

Phone : 022 - 2201 7083 & 51

M o b i l e N o . 9 0 0 4 6 0 8 2 8 3

Wensar Weighing Scales Limited

4-1-11/B, 2nd Floor, Tilak Road, Ram Kote,

Nr. Viswakarma Brahamana Sangam

H y d e r a b a d - 5 0 0 0 0 1 . ( I N D I A )

Phone No. : 040 - 24 75 40 02

M o b i l e N o . 7 7 0 2 9 9 9 9 3 5

1/33, LIG Square, LIG Colony ,

Indore - 452 001 (INDIA)

Phone : 0731 - 4036 333

Mobile No. 78989 06974

LUCKNOW

18, Chandganj Garden, Ground Floor,

K a p o o r t h a l a ,

Lucknow - 226 024 , ( INDIA)

P h o n e : 0 5 2 2 - 2 3 2 2 2 4 4

M o b i l e N o . 9 9 3 5 5 9 9 7 9 5

JAIPUR

C-85, 1st Floor, Near Sewararea

Rajendra Marg Bapu Nagar,

Jaipur - 302004 . ( INDIA )

Ph : 0141 - 2709456 / 4025106

Mobi le No. 78916 61567

CHENNAI

83, Audiappa Naicken Street,

Near Elephantgate, , Sowcarpet,

Chennai - 600079 (INDIA)

Phone : 044 - 2529 9212 / 13 / 14

HEAD OFFICE INDIA

Any typical error should not be consider