AMS® CAT BOSS™ Cleaner Procedure
-
Upload
arthurdoty -
Category
Documents
-
view
75 -
download
0
Transcript of AMS® CAT BOSS™ Cleaner Procedure
CAT BOSS
OPERATING INSTRUCTIONS
It is important that tools are
hydro-tested prior to each use.
Do not modify, change or adapt
any other equipment to these
tools. Do not use in confined
spaces. Do not use any
leverage device or pipe wrench
to assist tool.
• 1. Connect nitrogen hose
(with swivel) to tool.
• 2. Be certain packing
gland is tight and will not
leak during use.
• 3. Close vent valve (1/4
turn ball valve on side of
tool)
• 4. With tool fully
retracted, attach tool to
process connection.
Tighten sufficiently to
prevent leaks. Open
nitrogen supply to tool.
• 5. Open process valve
and check for leaks. If
any leaks, immediately
close process valve. If
no leaks appear, open
process valve to the full
open position.
• 6. Rotate ratchet handle
and push fully into
process
• 7. Open vent valve to
allow catalyst to be
removed from aeration
tap.
• 8. When aeration tap has
been cleared, there will
be no catalyst debris
venting from valve.
• 9. Close vent valve and
retract tool fully. When
fully retracted the
process valve can be
closed and the tool
removed from the
process connection.
NITROGEN FLOW
NITROGEN FLOW
1. connect
nitrogen
hose
2. check for
leaks at
packing
gland 3. close valve
4. attach tool to process
5. open process valve
6. rotate ratchet
handle and push
fully into process
NITROGEN FLOW
7. Open valve and vent catalyst debris