AMPAC EWIS

6
DUE TO AMPAC’S COMMITMENT TO CONTINUOUS IMPROVEMENT, SPECIFICATIONS MAY CHANGE WITHOUT NOTICE FOR A QUOTATION AND FURTHER INFORMATION, GO TO: www.ampac.net 46 Features EMERGENCY WARNING & INTERCOM SYSTEMS Modular system design – can be easily customised to meet special requirements Discrete front panel control ‘natural’ style layout easy to locate zones Amplifiers available are 40, 120, 240 & 480-watts – choice of amplifiers to suit your need Visual output for hearing impaired or noisy environments Common or individual fire alarm inputs – an “All Call” or staged evacuation may be configured 2-wire Warden Intercom Phones (WIP) or 3- wire if connecting to an Emergency Alarm Initiating Device (EAID) – monitored for open and short circuit Common or zoned background music inputs – non-emergency input that gives EV3000 the flexibility to fit most applications including shopping centres and hospitals; to name a few Monitoring of speaker circuits – monitoring for short or open circuit Monitoring of Visual Warning indicators – monitoring for short or open circuit Automatic volume control incorporating the ambient noise sensing microphone – ideal feature for applications where the ambient noise levels are different at various times of the day Fail safe volume override output – used as a control to shutdown all non-emergency facilities offered by the EV3000 and to override attenuated volume controls located in the field Stand-by signal generators – provides 100% backup of emergency tones for greater reliability Stand-by microphone amplifiers – provides 100% backup of emergency public address for greater reliability Automatic changeover to stand-by amplifier – automatic changeover to a stand-by amplifier may be configured in the event an active amplifier is faulty Digital paging console – attractive remote paging console with seven (7) segment digital display and keypad gives operator quick and easy access to paging zones Networked system – expands EV3000 features to include Master / Sub panel configuration, and remote paging console Optic Fibre Interface – the optional Optic Fibre Interface allows the EV3000 to be networked over optic fibre cables Product Information The Ampac EV3000 Occupant Warning and Intercom System is designed for the purpose of enabling the orderly evacuation of occupants, from a building or structure, in the event of an emergency. The system comprises of two (2) sub-systems. The first being the Occupant Warning System (OWS) and the other the Occupant Intercom System (OIS). While the Warning and Intercom System have separate controls, they coexist in a panel that is logically presented and aesthetically pleasing. The Occupant Warning System makes use of speakers strategically placed around the site, to broadcast ALERT, and/or EVACUATION signals or public address announcements. The OWS may be automatically initiated or manually operated. When not used in an emergency situation, the EV3000 can broadcast background music and/or general paging announcements. The Occupant Intercom System (OIS) consists of front panel control at the Emergency Control Panel (ECP) and Warden Intercom Phones (WIP) that are strategically placed throughout the building. Communication is only possible between the WIP and ECP. For larger sites, multiple control panels may be networked. EV3000 Emergency Warning & Intercom Systems REFER TO DATA SHEET: PDS105-0001 AS1670 version

Transcript of AMPAC EWIS

Page 1: AMPAC EWIS

DUE TO AMPAC’S COMMITMENT TO CONTINUOUS

IMPROVEMENT, SPECIF ICATIONS MAY CHANGE

WITHOUT NOTICE

FOR A QUOTATION AND FURTHER INFORMATION, GO TO:

w w w . a m p a c . n e t46

Features

EMERG

ENCY W

ARN

ING

&IN

TERCOM

SYSTEMS

• Modular system design – can be easily customised to meet special requirements

• Discrete front panel control – ‘natural’ style layout easy to locate zones

• Amplifi ers available are 40, 120, 240 & 480-watts – choice of amplifi ers to suit your need

• Visual output for hearing impaired or noisy environments

• Common or individual fi re alarm inputs – an “All Call” or staged evacuation may be confi gured

• 2-wire Warden Intercom Phones (WIP) or 3- wire if connecting to an Emergency Alarm Initiating Device (EAID) – monitored for open and short circuit

• Common or zoned background music inputs – non-emergency input that gives EV3000 the fl exibility to fi t most applications including shopping centres and hospitals; to name a few

• Monitoring of speaker circuits – monitoring for short or open circuit

• Monitoring of Visual Warning indicators – monitoring for short or open circuit

• Automatic volume control incorporating the ambient noise sensing microphone – ideal feature for applications where the ambient noise levels are different at various times of the day

• Fail safe volume override output – used as a control to shutdown all non-emergency facilities offered by the EV3000 and to override attenuated volume controls located in the fi eld

• Stand-by signal generators – provides 100% backup of emergency tones for greater reliability

• Stand-by microphone amplifi ers – provides 100% backup of emergency public address for greater reliability

• Automatic changeover to stand-by amplifi er – automatic changeover to a stand-by amplifi er may be confi gured in the event an active amplifi er is faulty

• Digital paging console – attractive remote paging console with seven (7) segment digital display and keypad gives operator quick and easy access to paging zones

• Networked system – expands EV3000 features to include Master / Sub panel confi guration, and remote paging console

• Optic Fibre Interface – the optional Optic Fibre Interface allows the EV3000 to be networked over optic fi bre cables

Product InformationThe Ampac EV3000 Occupant Warning and Intercom System is designed for the purpose of enabling the orderly evacuation of occupants, from a building or structure, in the event of an emergency. The system comprises of two (2) sub-systems. The fi rst being the Occupant Warning System (OWS) and the other the Occupant Intercom System (OIS). While the Warning and Intercom System have separate controls, they coexist in a panel that is logically presented and aesthetically pleasing.The Occupant Warning System makes use of speakers strategically placed around the site, to broadcast ALERT, and/or EVACUATION signals or public address announcements. The OWS may be automatically initiated or manually operated. When not used in an emergency situation, the EV3000 can broadcast background music and/or general paging announcements.The Occupant Intercom System (OIS) consists of front panel control at the Emergency Control Panel (ECP) and Warden Intercom Phones (WIP) that are strategically placed throughout the building. Communication is only possible between the WIP and ECP. For larger sites, multiple control panels may be networked.

EV3000

Emergency Warning & Intercom Systems

REFER TO DATA SHEET: PDS105-0001

A S 1 6 7 0 v e r s i o n

Page 2: AMPAC EWIS

DUE TO AMPAC’S COMMITMENT TO CONTINUOUS

IMPROVEMENT, SPECIF ICATIONS MAY CHANGE

WITHOUT NOTICE

FOR A QUOTATION AND FURTHER INFORMATION, GO TO:

w w w . a m p a c . n e t 47

EMERG

ENCY W

ARN

ING

&IN

TERCOM

SYSTEMS

Master EmergencyControl Panel (MECP)

Remote Paging Console

Secondary EmergencyControl Panel (SECP)

WIP

EAID

WIP EAID

Audio Bus

Communication Bus

Warden Intercom Point

Emergency Alarm Initiating Device

End-of-Line device

Speakers

Visual Warning Device

EOL

EOL

EOL

WIP EAID

Speakers

EOL

EOL

Fire AlarmControl Panel

Inputs

Background Music Inputs

240 VAC

Fire AlarmControl Panel

Inputs

Background Music Inputs

EV3000 (cont.) System Configuration

Emergency Warning & Intercom Systems

240 VAC

Visual Warning Device

Page 3: AMPAC EWIS

DUE TO AMPAC’S COMMITMENT TO CONTINUOUS

IMPROVEMENT, SPECIF ICATIONS MAY CHANGE

WITHOUT NOTICE

FOR A QUOTATION AND FURTHER INFORMATION, GO TO:

w w w . a m p a c . n e t48

Features

Features

Features

EMERG

ENCY W

ARN

ING

&IN

TERCOM

SYSTEMS

Voltage 24 VDCQuiescent current 58mAMax current 3400mAMax output power 40 WattsOutput voltage 100 VAC RMSFreq. Response 150Hz to 12kHz (±1dB)Distortion Max 1% at full load

(typical 0.5%)Sensitivity +5dB <200Kohm balanced)

(1.4VRMS)Overload 100 VRMS + 10%Weight 675 grams

• A modular power amplifier that is rated at40 watts

• Multi-channel audio input supports Alerttone, Evacuation tone, Public Address, andbackground music

• Continuous monitoring of amplifier and 100volt speaker circuit

• Overload protection with Automatic• Easily plugs into an Ampac EV3000 amplifier

frame• Can fit up to 8 amplifiers per frame

• A modular power amplifier that is rated at120 watts

• Multi-channel audio input supports Alerttone, Evacuation tone, Public Address, andbackground music

• Continuous monitoring of amplifier and100 volt speaker circuit

• Overload protection with Automatic• Easily plugs into an Ampac EV3000 amplifier

frame• Can fit up to 4 amplifiers per frame

Voltage 24 VDCQuiescent current 175mAMax current 8100mAMax output power 120 WattsOutput voltage 100 VAC RMSFreq. Response 210Hz to 14.5kHz (±1dB)Distortion < 0.2% at full loadSignal to Noise 77 dBOverload 100 VRMS + 10%Weight 1160 grams

Order Code 332-0004

• When utilised in the EV3000, this boardprovides 100% backup for the main microphoneand back ground music (BGM) input

• Provides amplification for microphone andimpedance matching for BGM input

• Only one (1) stand-by card is permitted persystem

Order Code 302-484B

Weight 230 grams

Order Code 154-0075

EV3000

40Watt Power Amplifier

REFER TO DATA SHEET: PDS154-0075

REFER TO DATA SHEET: PDS332-0004

120Watt Power Amplifier

Stand-by Microphone / BGM Mixer

EV3000 (cont.) Panel Add-ons

Emergency Warning & Intercom Systems

Page 4: AMPAC EWIS

DUE TO AMPAC’S COMMITMENT TO CONTINUOUS

IMPROVEMENT, SPECIF ICATIONS MAY CHANGE

WITHOUT NOTICE

FOR A QUOTATION AND FURTHER INFORMATION, GO TO:

w w w . a m p a c . n e t 49

Order Code Compliance Approved By

Features

Features

EMERG

ENCY W

ARN

ING

&IN

TERCOM

SYSTEMS

Weight 180 grams

• Each Power Supply Regulator Moduleincreases the charge current capacity of theEV3000 by 6.5 amperes

• Slots into the power supply frame (16U & 29Ucabinets only)

• Up to four (4) Power Supply Regulator Modulesper frame

It is important to check with the service contractor before adding modules to the EV3000

Weight 310 grams

Order Code 302-4822

Order Code Compliance Approved By

Order Code 302-491B

• When utilised in the EV3000, this boardprovides 100% backup for the main signal /speech generator

• Provides Alert and Evacuation signals toAS1670.4

• Playback of stored digitised speech• Only one (1) stand-by card is permitted

per system• Volume levels are factory set

Stand-by Signal / Speech Generator Board

EV3000

27 Volt Power Supply Regulator Module

EV3000 (cont.) Panel Add-ons

Emergency Warning & Intercom Systems

Features

Page 5: AMPAC EWIS

Order Code 154-0005

Order Code Compliance Approved By

Features

Features

Features

DUE TO AMPAC’S COMMITMENT TO CONTINUOUS

IMPROVEMENT, SPECIF ICATIONS MAY CHANGE

WITHOUT NOTICE

FOR A QUOTATION AND FURTHER INFORMATION, GO TO:

w w w . a m p a c . n e t50

EMERG

ENCY W

ARN

ING

&IN

TERCOM

SYSTEMS

Remote Paging Console

Operating Voltage 27 VDC (line driven)Line Voltage On hook - 25 VDC max

Off hook - 14 VDC maxCurrent draw On hook - 5 mA max

Off hook - 35 mA maxLine Impedance 360 ohm balancedLine Level 0 dB (± 3dB)Cabling 2 or 3 wire - 2.5mm2 max.Dimensions 215H x 85W x 62D mmWeight 380 grams

Order Code 219-0007 Warden Intercom Phone (WIP)291-0054 WIP Enclosure Metal Surface Mounted

Size 80H x 300W x 220D mmSupply voltage 12 VDCCurrent 400 mACommunication RS 485Weight 1160 grams

• The WIP is installed remote to the ECP• Provides intercommunication between users

at the WIP and Emergency Control Panel• This feature is only available when the

Emergency Warning Intercom facility hasbeen incorporated in the control panel

• Made of high impact red ABS plastic

• Provides a point to initiate a non-emergencyvoice announcement via the EV3000

• Provides a pre-announcement tone• Easy keypad operation to broadcast voice

announcements to selected zones, or group ofzones

• Connects to EV3000 via RS485• Derives power from the EV3000 panel

REFER TO DATA SHEET: PDS154-0005

REFER TO DATA SHEET: PDS219-0007

Warden Intercom Phone

EV3000 (cont.) Panel Add-ons

Emergency Warning & Intercom Systems

Page 6: AMPAC EWIS

DUE TO AMPAC’S COMMITMENT TO CONTINUOUS

IMPROVEMENT, SPECIF ICATIONS MAY CHANGE

WITHOUT NOTICE

FOR A QUOTATION AND FURTHER INFORMATION, GO TO:

w w w . a m p a c . n e t 51

EMERG

ENCY W

ARN

ING

&IN

TERCOM

SYSTEMS

MECHANICAL SPECIFICATIONS

Material 1.6mm Mild SteelFinish Powder Coated Arch WhiteDimensions 10U 700H x 625W x 240D mm (SECP only)

12U 900H x 650W x 290D mm 16U 1200H x 700W x 375D mm 29U 1800H x 700W x 375D mmApprovals SSL – AS2220.89Signals Compliant with AS1670.4:2004

ELECTRICAL

Power Supply 6.5, 13, 19.5 or 26 Amps @ 24 VDCCommunication RS485 @ 9600 bpsEWS Zones 144 maxEIS Zones 288 maxPaging Console 8 max (recommended)ECP’s 12 max (recommended)Visual Warning 8 max per circuit

INDICATORS

Description Colour

Common Isolate (Keyswitch) Amber Automatic (Keyswitch) Green All Call PA Green All Call Alert Amber All Call Evac Red Power On Green System On Batteries Red Charger Fault Amber Battery Fault Amber Battery Isolated Amber Tone Fault Amber ECP in Control Red Alarm System Isolate Amber Comms Fault Amber System Fault Amber Module Fault Amber Microphone Fault Amber Amplifier/Speaker Fault Amber EAID Fault Amber Visual Line Fault Amber Alarm System Fault AmberEWS Zone P.A. Green Alert Amber Evac Red Fault Amber Alarm RedEIS Zone WIP Select Red Zone Cleared Green Fault Amber

Order Code Model Compliance Approved By105-0001 12 U MECP AS2220 SSL105-0002 16 U MECP AS2220 SSL105-0003 29 U MECP AS2220 SSL105-0004 10 U SECP AS2220 SSL105-0005 12 U SECP AS2220 SSL105-0006 16 U SECP AS2220 SSL

E V 3 0 0 0 1 2 U

Wa r d e n I n t e r c o m P h o n e

R e m o t e Pa g i n g C o n s o l e

Emergency Warning & Intercom Systems

EV3000 (cont.)System to AS2220:89Signals to AS1670.4