Ammonia cracker

4
HEAT TREATMENT FURNACES FOURS DE TRAITEMENT THERMIQUE photos for illustration only 70 CRACKED AMONIAC GENERATOR 950°C GE 950 Definition: Cracked ammonia generator for heat treatment, brazing and welding. Construction: Mechanically welded frame. Insulation: Heated retort is insulated with ceramics. Heating: Heating elements surrounded working chamber. Electricity: 3 x 400VAC. Regulation: Axron Swiss PID temperature controller. Time programmer for delayed on/off. Documentation: Certification CE and operating instructions in English. Type of gas: Ammonia cracking: at output, constant composi- tion of 25% nitrogen and 75% hydrogen. For 1kg of ammonia, 2.7 m3 of strongly reducing protective gas is produced. Définition: Générateur d’ammoniac craqué pour traitements thermiques, brasage et soudage (sans oxydation ni colora- tion). Construction: Châssis mécano-soudé. Isolation: Isolation céramique de la cornue chauffée. Chauffage: Eléments chauffants entourant l’enceinte utile. Electrique: Tension 3x400VAC, fréquence 50Hz. Régulation: Régulateur PID Axron Swiss. Programmateur ho- raire pour mise en marche/arrêt différé. Documentation: Certification CE, notice d’utilisation en français. Type de gaz: Craquage de l’ammoniac: en sortie composition constante de 25% d’azote et 75% d’hydrogène. Pour 1Kg d’ammoniac, on obtient 2,7 m3 de gaz de protection fortement réducteur. 601 MODEL ITEM CODE Ext. Dim. (WxHxD) (mm) Max Flow (m 3 / hour) Number of independant outlet Power (kW) Weight (kg) GE 950-3 N810066 560 x 865 x 810 3 2 3 152 GE 950-7 B111765 850 x 1000 x 560 7 3 7 220 Specifications subject to change Borel Swiss SA - A Division of SOLO Swiss Group Rouges-Terres 61 - 2068 Hauterive - Switzerland - [email protected] - www.borel.eu - Tel. +41 32 756 64 00 - Fax +41 32 756 64 48

description

 

Transcript of Ammonia cracker

Page 1: Ammonia cracker

HEAT TREATMENT FURNACESFOURS DE TRAITEMENT THERMIQUE

photos for illustration only

70

CRACKED AMONIAC GENERATOR 950°CGE 950

Definition: Cracked ammonia generator for heat treatment, brazing and welding.Construction: Mechanically welded frame.Insulation: Heated retort is insulated with ceramics.Heating: Heating elements surrounded working chamber.Electricity: 3 x 400VAC. Regulation: Axron Swiss PID temperature controller. Time programmer for delayed on/off.Documentation: Certification CE and operating instructions in English.Type of gas: Ammonia cracking: at output, constant composi-tion of 25% nitrogen and 75% hydrogen. For 1kg of ammonia, 2.7 m3 of strongly reducing protective gas is produced.

Définition: Générateur d’ammoniac craqué pour traitements thermiques, brasage et soudage (sans oxydation ni colora-tion).Construction: Châssis mécano-soudé.Isolation: Isolation céramique de la cornue chauffée.Chauffage: Eléments chauffants entourant l’enceinte utile.Electrique: Tension 3x400VAC, fréquence 50Hz. Régulation: Régulateur PID Axron Swiss. Programmateur ho-raire pour mise en marche/arrêt différé.Documentation: Certification CE, notice d’utilisation en français.Type de gaz: Craquage de l’ammoniac: en sortie composition constante de 25% d’azote et 75%d’hydrogène. Pour 1Kg d’ammoniac, on obtient 2,7 m3 de gaz de protection fortement réducteur.

601

MODEL ITEM CODE Ext. Dim. (WxHxD) (mm)

Max Flow(m3 / hour)

Number of independant outlet

Power (kW)

Weight (kg)

GE 950-3 N810066 560 x 865 x 810 3 2 3 152

GE 950-7 B111765 850 x 1000 x 560 7 3 7 220

Specifications subject to change

Borel Swiss SA - A Division of SOLO Swiss GroupRouges-Terres 61 - 2068 Hauterive - Switzerland - [email protected] - www.borel.eu - Tel. +41 32 756 64 00 - Fax +41 32 756 64 48

Page 2: Ammonia cracker

HEAT TREATMENT FURNACESWÄRMEBEHANDLUNGSÖFEN

photos for illustration only

70

CRACKED AMONIAC GENERATOR 950°CGE 950

Definition: Cracked ammonia generator for heat treatment, brazing and welding.Construction: Mechanically welded frame.Insulation: Heated retort is insulated with ceramics.Heating: Heating elements surrounded working chamber.Electricity: 3 x 400VAC, 50Hz. Regulation: Axron Swiss PID temperature controller. Time programmer for delayed on/off.Documentation: Certification CE and operating instructions in English.Type of gas: Ammonia cracking: at output, constant composi-tion of 25% nitrogen and 75% hydrogen. For 1kg of ammonia, 2.7 m3 of strongly reducing protective gas is produced.

Definition: Ammoniak-Spaltgas-Generator für Wärmebehandlungen, Löten und Schweißen (ohne Oxidation tion).Konstruktion: Geschweißte Rahmenkonstruktion.Isolierung: Mehrschichtenisolierung. Feuerfeste Keramik-Isolierung. Heizung: Heizelemente um den Nutzraum.Elektrisch: Spannung 3 x 400VAC, Frequenz 50Hz. Regulierung: Axron Swiss PID-Regler . Programmierbarer Timer für verzögerte Ein- und Ausschaltung.Documentation: CE-Zertifizierung und Bedienungsanleitung in Deutsch. Gastyp: Spalten von Ammoniak, konstante Zusammensetzung Zusammensetzung von 25% Stickstoff und 75% Wasserstoff. Für 1kg Ammoniak erhält man 2,7 m³ Schutzgas.

601

MODEL ITEM CODE Ext. Dim. (WxHxD) (mm)

Max Flow(m3 / hour)

Number of independant outlet

Power (kW)

Weight (kg)

GE 950-3 N810066 560 x 865 x 810 3 2 3 152

GE 950-7 B111765 850 x 1000 x 560 7 3 7 220

Specifications subject to change

Borel Swiss SA - A Division of SOLO Swiss GroupRouges-Terres 61 - 2068 Hauterive - Switzerland - [email protected] - www.borel.eu - Tel. +41 32 756 64 00 - Fax +41 32 756 64 48

Page 3: Ammonia cracker

HEAT TREATMENT FURNACESHORNOS DE TRATAMIENTO TERMICO

photos for illustration only

70

CRACKED AMONIAC GENERATOR 950°CGE 950

Definition: Cracked ammonia generator for heat treatment, brazing and welding.Construction: Mechanically welded frame.Insulation: Heated retort is insulated with ceramics.Heating: Heating elements surrounded working chamber.Electricity: 3 x 400VAC. Regulation: Axron Swiss PID temperature controller. Time programmer for delayed on/off.Documentation: Certification CE and operating instructions in English.Type of gas: Ammonia cracking: at output, constant composi-tion of 25% nitrogen and 75% hydrogen. For 1kg of ammonia, 2.7 m3 of strongly reducing protective gas is produced.

Definición: Generador de amoníaco craqueado para tratamientotérmico, pulimento y soldadura (sin oxidación ni coloración).Construcción: Chasis mecanosoldado.Aislamiento: Aislamiento cerámico de la retorta caliente.Calefacción: Elementos calefactores alrededor del recinto útil.Eléctrico: Tensión 3x400VAC, frecuencia 50Hz.Regulación: Regulador PID Axron Swiss. Programador horariopara puesta en marcha/interrupción diferida.Documentación: Certificación CE, manual de uso.Tipo de gas: Craqueado del amoníaco: en salida composición constante de 25% de nitrógeno y 75% de hidrógeno. Para 1Kgde amoníaco, se obtienen 2,7 m3 de gas de protección altamentereductor.

601

MODEL ITEM CODE Ext. Dim. (WxHxD) (mm)

Max Flow(m3 / hour)

Number of independant outlet

Power (kW)

Weight (kg)

GE 950-3 N810066 560 x 865 x 810 3 2 3 152

GE 950-7 B111765 850 x 1000 x 560 7 3 7 220

Specifications subject to change

Borel Swiss SA - A Division of SOLO Swiss GroupRouges-Terres 61 - 2068 Hauterive - Switzerland - [email protected] - www.borel.eu - Tel. +41 32 756 64 00 - Fax +41 32 756 64 48

Page 4: Ammonia cracker

HEAT TREATMENT FURNACESFORNI PER TRATTAMENTO TERMICO

photos for illustration only

70

CRACKED AMONIAC GENERATOR 950°CGE 950

Definition: Cracked ammonia generator for heat treatment, brazing and welding.Construction: Mechanically welded frame.Insulation: Heated retort is insulated with ceramics.Heating: Heating elements surrounded working chamber.Electricity: 3 x 400VAC. Regulation: Axron Swiss PID temperature controller. Time programmer for delayed on/off.Documentation: Certification CE and operating instructions in English.Type of gas: Ammonia cracking: at output, constant composi-tion of 25% nitrogen and 75% hydrogen. For 1kg of ammonia, 2.7 m3 of strongly reducing protective gas is produced.

Definizione: Generatore di ammoniaca dissociata per trattamenti termici, brasatura e saldatura (senza ossidazione né colorazione).Struttura: Telaio saldato meccanicamente.Isolamento: Isolamento ceramico della storta riscaldata.Riscaldamento: Elementi riscaldanti che circondano la cassa utile.Parte elettrica: Tensione CA 230V, frequenza 50 Hz.Regolazione: Regolatore PID Axron Swiss. Programmatore orario per l'accensione/lo spegnimento in differita.Documenti: Certificazione CE, istruzioni per l'uso.Tipo di gas: Dissociazione dell'ammoniaca: in uscita composizione costante con il 25% di azoto e il 75% di idrogeno. Con 1 kg di ammoniaca si ottengono 2,7 m3 di gas di protezione fortemente riduttore.

601

MODEL ITEM CODE Ext. Dim. (WxHxD) (mm)

Max Flow(m3 / hour)

Number of independant outlet

Power (kW)

Weight (kg)

GE 950-3 N810066 560 x 865 x 810 3 2 3 152

GE 950-7 B111765 850 x 1000 x 560 7 3 7 220

Specifications subject to change

Borel Swiss SA - A Division of SOLO Swiss GroupRouges-Terres 61 - 2068 Hauterive - Switzerland - [email protected] - www.borel.eu - Tel. +41 32 756 64 00 - Fax +41 32 756 64 48