Alcatel-Lucent University Antwerp 1
University
Alcatel 7302 ISAM
2
7302 ISAM Interfaces
Ø7302 User Interfaces§ ADSL/ADSL2/RE-ADSL2/ADSL2+, annex.M§ VDSL§ SHDSL§ Direct Ethernet over fiber
Ø7302 ISAM
ISAMCO
DSL Access
fiber Access
Subtending Links
FE/GE Uplinks
Ethernet Switch/Router
Ø7302 network Interfaces§ Uplinks, subscribers or
subtending
§ FE/GE Optical/Electrical
Alcatel-Lucent University Antwerp 3
University
General Topology
4
Subtending vs. Expansion topologies (1/2)
CO
EthernetSwitch
7330 host
Cabinet/MDU
7342
7302
7330 host
CO or Cabinet
7356 REM-FD
7330 REM
expansion link
subtendinglink
7330 RA 7357 SEM-FD
5
Subtending vs. Expansion topologies (2/2)
Øsubtending§ connecting multiple ISAM systems (7302 CO or 7330 host)
via Ethernet subtending links§ standalone nodes: each node provides the Ethernet switch and aggregation
function and is managed separately
Øexpansion§ connecting ISAM host shelf (7330 only) with remote LTs,
via expansion links (optical)§ switch and aggregation function in host shelf only§ one system: host shelves are managed together as a single system
6
Terminology and interfaces (1/2)
Ø No expansion link in the 7302 ISAM
7302 ISAM
Eth
NT
Aggr Function
Contr function
Physical user links•ADSL/ADSL2/READSL2•ADSL2+•VDSL2 - EFM•SHDSL – EFM or ATM•Optical Ethernet
LT
Subtending•GE/FE •optical/electrical
User link•GE/FE •optical/electrical
Control links•FE - electrical
ASAM links•GE - electrical
network link•GE/FE •optical/electrical
7
Terminology and interfaces (2/2)
Eth
NT
Contr function
Aggr Function User link
•GE/FE •optical/electrical
Physical user links•ADSL/ADSL2/READSL2•ADSL2+•VDSL2 - EFM•SHDSL – EFM or ATM•Optical Ethernet
LT
LT
REM
Physical user linksxDSL
network link•GE opt./elect.•FE electrical.
7330 ISAMFTTN HOST
ASAM links•GE - electrical
expansion links•GE - optical
Subtending•GE/FE •optical/electrical
GENCNCNC
Alcatel-Lucent University Antwerp 8
University
Equipment Practice
9
Equipment practice
Ø eXtreme Density - XD § ISAM 7302 16 slot ETSI
dedicated shelf for line boardsdedicated shelf for splitters
§ ISAM 7330 FTTN 4 slot ETSIline and splitter boards are in same shelf
§ Remote Expansion Module1 line board and 1 splitter board in a separate enclosure behaving as a remote
LT connecting to an 7330 FTTN host shelf
Ø Flexible Density – FD§ universal slot concept allows any mix of xDSL LTs, splitters, fiber LTs,
voice cards in the same shelfNT-B slot + NT I/O slot can be used as LT slot
§ ISAM 7302 16/18 slot ETSI§ ISAM 7330 FTTN 8/10 slot ETSI§ Remote expansion Module (FTTB 7356)
1 line board ,1 splitter board and/or 1 POTS board in a separate enclosure behaving as remote LT’s connecting to an 7330 FTTN host shelf.
Alcatel-Lucent University Antwerp 10
University
Equipment Practice - XD
Extreme Density
11
General architecture 7302 ISAM-XD
Ø XD equipment practice
Ø 16 LT boards§ 48 lines/LT
§ Each LT contains an IWF
§ separate splitter shelf
Ø Aggregation (service hub) and control- & management function integrated on NT
Ø 1GE connectivity between NT and LT via backpanel
Ø SMAS card§ System MAC address
storage
ASAM-shelf
ASAM link
Control link
LT 1 LT 16
NT
Aggregation function
Control/Mgt function
(FE)
1 …16 GE1..3/4 GE/FE
SMAS
48 lines
NT I/O
4 External Ethernet links
1..4 GE/FE
3/4 External Ethernet links
ACU
ACU
SMA
S
Clock
Power
802.3port
802.3port
LT module LT module
12
XD shelf types
Ø ISAM 7302 - XD§ XD-LT ALTS-T
ETSI shelf for 16 line boards (48 lines)
§ XD-SP ASPS-AETSI splitter shelf with backplane for 16 splitter boards (48 lines)
§ XD-SP ASPS-C16 slot ETSI splitter shelf without backplane for 16 splitter boards (48 lines)
Ø ISAM 7330 FTTN - XD§ XD-ARAM-D
mini-RAM shelf for 4 line boards (LT 48 lines)
Ø REM-XD§ EREM-A
1XD-LT – 24 ports VDSL and 1 XD-PScan be connected to 7330 FTTN XD or FD
13
XD equipment practice
Ø Single-shelf ASAM equipment practice § XD-LT ETSI splitterless shelf
ALTS-T
Ø Mounted in ISAM XD RACK (with TRU)§ LEDs
§ power:incoming from office battery
outgoing to shelves
Ø Different rack configurations§ splitterless deployment
Max 2 shelves per rack
2 ISAM systems per rack
§ Deployment with splitters integrated in rack1 shelf per rack
1 ISAM system per rack
TRU
SUB 2
SUB 1
splitterless deployment
14
XD rack configurations
splitterless deployment2 ISAM systems in 1 rack
TRU
splitterlessshelf 1
splitterlessshelf 2
dust filter
TRU
splitterlessshelf 1
dust filter
splitterless deployment1 ISAM systems in 1 rack
combo deploymentsplitters integrated in rack
TRU
splittershelf
splitterlessshelf
dust filter
15
Dust filter
ALTS-T – Line terminating shelfA
CU
LTLT LT LT LT LT LT LT LT LT LT LT LT LT LTNT
connectorarea
line boardarea
fan area
ISAM NT I/ON
T
AC
U
SMAS
Fan unit
PWR
LT
XDSL x 24
LT board
Back panel
LINE(1..24)
LINE(25..48)
FANdust filter
XDSL x 24
16
Other system components
top rack unit
Up to 2 XD LT shelves per rack
splitter shelf can be integratedin rack or separate (as shown)
ATRU-Q
• power provisioning• fuses for boards/fans
air flow
XD LT shelves
Fan unitsAFAN-H
• with or without dust filter
17
ECNT – Network termination board – XD (1/2)
Ø service hub § 24 Gbps line rate capacity§ 16 port reserved for line cards &
expansions§ 1 (0) port to the control & mgt function§ 7 (8) ports remaining for Ethernet user
links, subtending links and network links
Øcontains FLASH, RAM and ROM memoryØ interfacing with management and
control interfaces via backpanelØ traffic management on NT
ECNT-AECNT-C
18
ECNT – network termination board – XD (2/2)
LEDs
Op
tica
litf
sEl
ect
rica
l it
fs port
0:
op
tica
l or
ele
ctri
cal
port
1,2
,3 à
op
tica
l
ECNT-A: 3 Ethernet interfaces§ 2 variants: 100 Mb or 1Gb to each LT§ RJ45 auto-sensing 10/100/1000Base-T§ On board media conversion to GE optical§ SFP optical modules required§ Flash memory is 256 M
ECNT-C: 4 Ethernet interfaces§ 3 x 1Gbps SFP port§ 1 x 10/100/1000Mbps port electrical or
1Gbps optical§ Flash memory is 512 M
Ø ECNT is used in:§ 7302 ISAM XD§ 7330 ISAM FTTN XD
19
NT I/O – Network termination I/O board
Ø provides 4 additional (external) Ethernet interfaces
Ø ECNC-A§ RJ45 auto-sensing 10/100/1000Mbps
§ Or optical interfaces (1G only)
Ø ECNC-B§ FE optical interfaces
Ø SFP optical modules required
Ø RJ45 for test access (connection to TAU)
20
EBLT – MultiDSL line termination board
Ømulti-ADSL line card§ 48 ports per card
§ ADSL/ADSL2/READSL2/ADSL2+ line termination
§ POTS and ISDN line cards
Ø GE interface towards NT
Ø ATM cell <-> Ethernet packet conversion§ Inter Working Function (IWF)
Ø L2 and L3 cards§ difference in supported FW Models, QoS,...
EBLT-C-E (POTS, L3) EBLT-D-F (ISDN, L3)EBLT-J (POTS, L2)…
21
EVLT – VDSL line termination board
Ø VDSL line card§ 24 ports per card
§ POTS and ISDN line cards
Ø GE interface towards NT
EVLT-C (ETSI/POTS)EVLT-D (ETSI/ISDN)
22
SMLT – SHDSL line termination board - XD
Ø SHDSL line card§ symmetric service:
bit rate from 192 kbps to 5696 kbps
à in steps of 64 kbps
§ 24 ports per card
§ EFM or ATM/IMA
Ø GE interface towards NT
SMLT-J
SMLT-K
23
ACU – Alarm Control Unit in 7302 ISAM XD
Ø inserted in the leftmost slot of the splitterless shelf (ALTS-T)
Ø five LED’s to indicate different levels of fault conditions§ ACO/lamp test push button switch
Ø craft interface § 9-pin D-connector
Ø Ethernet connection § RJ-45 for out-band mgmt
§ cannot be used
Ø one ACU/ISAM system
AACU-C
Alcatel-Lucent University Antwerp 24
University
Equipment Practice - FD
Flexible Density
25
ISAM FD shelf – Flexible Density Equipment Practice
Ø FD slots are universal: can hold LTs as well as splitters
Ø Higher densities can be obtained with FD shelves § One rack may contain 3 FD shelves compared to only 2 XD shelves
Ø Various FD splitters will be availablemultiDSL and VDSL2
POTS-only and universal POTS/ISDN
Mul
ti-A
DS
L
VD
SL2
PO
TSIS
DN
fiber
(p2p
Eth
)
split
ters
Multiple flavors of line cards availableMultiple density variants (28p, 48p)
Single shelf for all deployments
•DSL•voice•fiber
26
General architecture 7302 ISAM-FD
Ø new equipment practice – NEP§ NFXS-A
Ø capacity = 16 + 2 line slotsNT-B/NTIO slots can be used as line slot
Ø universal slot concept§ shelf can accomodate any mix of
xDSL LTs, splitters, fiber LTs, voice cards
Ø aggregation (service hub) and control- & management function integrated on NT
Ø 1GE connectivity between NT and LT via backpanel§ Backplane ready to support evolution
to higher densities
Ø ACU & clock function integrated on NT board
Ø SMAS functionality integrated on backpanel
7302 FD-shelf
ASAM link
Control link
NT
Aggregation function (SHUB)
1 …16/18 GE2 GE
1..6 GE2 External Ethernet links
Control/Mgtfunctions ACU Clock
6 External Ethernet links
LT16à 18or SP16à 18ormixed
SMAS
NTIO 802.3port
802.3port
Power
27
Shelf types – FD equipment practice
Ø ISAM 7302 - FD§ FD -NFXS-A
ETSI shelf for 16/18 boards (x lines)universal slot concept allows any mix of xDSL LTs, splitters, fiber LTs,
voice cards
Ø ISAM 7330 FTTN - FD§ FD-NFXS-B
Mini-RAM ETSI shelf for 8/10 boards (x lines)universal slot concept allows any mix of xDSL LTs, splitters, fiber LTs,
voice cards
Ø 7356 FTTB REM - FD§ FD-NFXR-A
can be connected to 7330 FTTN XD or FD.
28
7302 ISAM–FD shelf: NFXS-A
Ø No connector area: direct front access cabling
Ø 2 NT slots + 1 NTIO slot
Ø 16 “LT/splitter” slots
Ø Capacity = 16 + 2 line slots§ NT-B/NTIO slots can be used as
line slot
§ Max 864 lines/shelf
500 W x 600 H x 280 D
600
LT/splitter slots LT/splitter slots2 x NT + NTIO
FAN
29
7302 ISAM–FD shelf: NFXS-A
Card cage area
DSL
LT board
Back panel
FANdust filter
LT LT LT LT LT LTLT LT LT LT LT LT LT LT LTLT
NTA
NTB
/LT
NTI
O/L
T
Power & connectorarea
PWRDust filter
Fan unit
fiber conduct
Fan area
fiber channel
fiber conduct
30
7302 ISAM-FD shelf – configurations LT shelves
XDSL cable management area
48p -
LT
Fan unit
48p-
LTNT
NT
IO
TAUBITS
Craft
BITS
Craft
Mgt
SFP4
SFP1
SFP5
SFP6
SFP7
SFP8
SFP3
SFP2 SFP2
NT
Mgt
SFP1
AD
SL 1
-48
connectorarea
BAT filersInletBlock
CBsLamps
connectorarea
PWR filtersPWRInletBlock
CBsLEDS
fiber management areaFan unit
BPA
XDSL cable management area
48p -
LT
Fan unit
48p-
LTNT
NT
IO
TAUBITS
Craft
BITS
Craft
Mgt
SFP4
SFP1
SFP5
SFP6
SFP7
SFP8
SFP3
SFP2 SFP2
NT
Mgt
SFP1
AD
SL 1
-48
connectorarea
BAT filersInletBlock
CBsLamps
connectorarea
PWR filtersPWRInletBlock
CBsLEDS
fiber conduct areaFan unit
BPA
FD CO 16 slot LT shelf with NT redundancy
FD CO 18 slot LT shelf no NTIO / no NT redundancy
(e.g. HSI only application)
XDSL cable management area
48p-
LT
Fan unit
48p-
LTNT
NT
IOTAUBITS
Craft
BITS
CraftMgt
SFP4
SFP1
SFP5
SFP6
SFP7
SFP8
SFP3
SFP2 SFP2
NT
Mgt
SFP1
AD
SL 1-
48
connectorarea
BAT filersInletBlock
CBsLamps
connectorarea
PWR filtersPWRInletBlock
CBsLEDS
fibermanagement areaFan unit
BPA
XDSL cable management area
48p-
LT
Fan unit
48p-
LTNT
NT
IOTAUBITS
Craft
BITS
CraftMgt
SFP4
SFP1
SFP5
SFP6
SFP7
SFP8
SFP3
SFP2 SFP2
NT
Mgt
SFP1
AD
SL 1-
48
connectorarea
BAT filersInletBlock
CBsLamps
connectorarea
PWR filtersPWRInletBlock
CBsLEDS
fiber conduct areaFan unit
BPA
XDSL XDSL
31
7302 ISAM FD shelf – configurations LT/splitter shelf
FD CO 16 slot shelf with NT redundancy
48p-
LT
Fan unit
48p-
LTNT
NT
IO
TAUBITS
Craft
BITS
Craft
Mgt
SFP4
SFP1
SFP5
SFP6
SFP7
SFP8
SFP3
SFP2 SFP2
NT
Mgt
SFP1
AD
SL
1-48
Connectorarea
BAT filersInletBlock
CBsLamps
Connectorarea
PWR filtersPWRInletBlock
CBsLEDS
Fiber management areaFan Unit
BPA
POTSLINE
XDSL
LT SP LT SP
48p-
LT
Fan unit
48p-
LTNT
NT
IO
TAUBITS
Craft
BITS
Craft
Mgt
SFP4
SFP1
SFP5
SFP6
SFP7
SFP8
SFP3
SFP2 SFP2
NT
Mgt
SFP1
AD
SL
1-48
Connectorarea
BAT filersInletBlock
CBsLamps
Connectorarea
PWR filtersPWRInletBlock
CBsLEDS
Fiber management areaFan Unit
BPA
POTSLINE
XDSL
LT SPLT SP LT SPLT SP
FD CO 18 slot shelf without NT redundancy
32
NANT - Combined NT unit
Ø service hub § 24 Gbps line rate capacity
§ Supports i.f.o setup/configurationUp to18 LT cards
Up to 8 ports for Ethernet user links, subtending links and network links
Up to 12 ports for expansion links
i.f.o available links on NTIO board
Ø contains FLASH, RAM and ROM memory
Ø interfacing with management and control interfaces via backpanel
Ø traffic management on NT
Ø ACU module integrated on NT
NANT-A
33
NANT-A - Combined NT unit version A
Ø NANT à used in:§ 7302 ISAM FD§ 7330 ISAM FTTN FD
Ø 1 Craft interface (RJ45)Ø 1 BITS interface (RJ45)
§ Availability I.f.o variant
Ø 1 100BaseT outband Mgt interface§ Not used at the moment
Ø 2 ports for user/network/subtending links § 1 GE Optical SFP and § 1 switchable GE Optical SFP/RJ-45
Ø Flash memory is 512 M
RJ45 BITS (AB variant only)
RJ45 Craft
RJ45 Outband Managemen (LOM)
RJ45 Uplink 1
SFP Uplink 1
SFP Uplink 2
switchable
34
NCNC - NT I/O Applique version B
Ø6 optical GE Eth interfaces to the active NT board.
Øserial TAUS interface to the TAU board.
ØEnvironment Monitoring interface to communicate with a monitor box over a RS-232 link.
NCNC-B
35
NALT – MultiDSL Line Termination Unit
Ø multi-ADSL line card§ 48 ports per card§ ADSL, ADSL2, ADSL2+, READSL and
Annex M§ POTS and ISDN line cards
Ø Front access connector on the LT board.
Ø GE interface towards NTØ ATM cell <-> Ethernet packet
conversion§ Inter Working Function (IWF)
Ø L2 and L3 cards§ difference in supported FW Models,
QoS,...NALT-B (POTS, L2, 48 ports) NALT-C (POTS, L3, 48 ports)NALT-D (ISDN, L3, 48 ports)…
36
NSLT – SHDSL Line Termination unit
ØSHDSL line card§ symmetric service:
bit rate from 192 kbps to 5696 kbps
à in steps of 64 kbps
§ 24 ports per card
§ EFM or ATM/IMA
ØGE interface towards NT
NSLT-A 24 SHDSL
37
NVLT – VDSL(2) Line Termination unit
ØVDSL line card§ 24 or 48 ports per card
§ POTS and ISDN line cards
ØSupport VDSL(2) and ADSL(2+)
ØGE interface towards NT
NVLT-A 24 VDSL(2) POTS
NVLT-B 24 VDSL(2) ISDN
NVLT-C 48 VDSL(2)-ADSL(2+) POTS
NVLT-D 48 VDSL(2)-ADSL(2+) ISDN