Alu 7302 Isam

38
Alcatel-Lucent University Antwerp 1 University Alcatel 7302 ISAM
  • Upload

    m
  • Category

    Documents

  • view

    635
  • download

    60

description

Alu 7302 Isam

Transcript of Alu 7302 Isam

Page 1: Alu 7302 Isam

Alcatel-Lucent University Antwerp 1

University

Alcatel 7302 ISAM

Page 2: Alu 7302 Isam

2

7302 ISAM Interfaces

Ø7302 User Interfaces§ ADSL/ADSL2/RE-ADSL2/ADSL2+, annex.M§ VDSL§ SHDSL§ Direct Ethernet over fiber

Ø7302 ISAM

ISAMCO

DSL Access

fiber Access

Subtending Links

FE/GE Uplinks

Ethernet Switch/Router

Ø7302 network Interfaces§ Uplinks, subscribers or

subtending

§ FE/GE Optical/Electrical

Page 3: Alu 7302 Isam

Alcatel-Lucent University Antwerp 3

University

General Topology

Page 4: Alu 7302 Isam

4

Subtending vs. Expansion topologies (1/2)

CO

EthernetSwitch

7330 host

Cabinet/MDU

7342

7302

7330 host

CO or Cabinet

7356 REM-FD

7330 REM

expansion link

subtendinglink

7330 RA 7357 SEM-FD

Page 5: Alu 7302 Isam

5

Subtending vs. Expansion topologies (2/2)

Øsubtending§ connecting multiple ISAM systems (7302 CO or 7330 host)

via Ethernet subtending links§ standalone nodes: each node provides the Ethernet switch and aggregation

function and is managed separately

Øexpansion§ connecting ISAM host shelf (7330 only) with remote LTs,

via expansion links (optical)§ switch and aggregation function in host shelf only§ one system: host shelves are managed together as a single system

Page 6: Alu 7302 Isam

6

Terminology and interfaces (1/2)

Ø No expansion link in the 7302 ISAM

7302 ISAM

Eth

NT

Aggr Function

Contr function

Physical user links•ADSL/ADSL2/READSL2•ADSL2+•VDSL2 - EFM•SHDSL – EFM or ATM•Optical Ethernet

LT

Subtending•GE/FE •optical/electrical

User link•GE/FE •optical/electrical

Control links•FE - electrical

ASAM links•GE - electrical

network link•GE/FE •optical/electrical

Page 7: Alu 7302 Isam

7

Terminology and interfaces (2/2)

Eth

NT

Contr function

Aggr Function User link

•GE/FE •optical/electrical

Physical user links•ADSL/ADSL2/READSL2•ADSL2+•VDSL2 - EFM•SHDSL – EFM or ATM•Optical Ethernet

LT

LT

REM

Physical user linksxDSL

network link•GE opt./elect.•FE electrical.

7330 ISAMFTTN HOST

ASAM links•GE - electrical

expansion links•GE - optical

Subtending•GE/FE •optical/electrical

GENCNCNC

Page 8: Alu 7302 Isam

Alcatel-Lucent University Antwerp 8

University

Equipment Practice

Page 9: Alu 7302 Isam

9

Equipment practice

Ø eXtreme Density - XD § ISAM 7302 16 slot ETSI

dedicated shelf for line boardsdedicated shelf for splitters

§ ISAM 7330 FTTN 4 slot ETSIline and splitter boards are in same shelf

§ Remote Expansion Module1 line board and 1 splitter board in a separate enclosure behaving as a remote

LT connecting to an 7330 FTTN host shelf

Ø Flexible Density – FD§ universal slot concept allows any mix of xDSL LTs, splitters, fiber LTs,

voice cards in the same shelfNT-B slot + NT I/O slot can be used as LT slot

§ ISAM 7302 16/18 slot ETSI§ ISAM 7330 FTTN 8/10 slot ETSI§ Remote expansion Module (FTTB 7356)

1 line board ,1 splitter board and/or 1 POTS board in a separate enclosure behaving as remote LT’s connecting to an 7330 FTTN host shelf.

Page 10: Alu 7302 Isam

Alcatel-Lucent University Antwerp 10

University

Equipment Practice - XD

Extreme Density

Page 11: Alu 7302 Isam

11

General architecture 7302 ISAM-XD

Ø XD equipment practice

Ø 16 LT boards§ 48 lines/LT

§ Each LT contains an IWF

§ separate splitter shelf

Ø Aggregation (service hub) and control- & management function integrated on NT

Ø 1GE connectivity between NT and LT via backpanel

Ø SMAS card§ System MAC address

storage

ASAM-shelf

ASAM link

Control link

LT 1 LT 16

NT

Aggregation function

Control/Mgt function

(FE)

1 …16 GE1..3/4 GE/FE

SMAS

48 lines

NT I/O

4 External Ethernet links

1..4 GE/FE

3/4 External Ethernet links

ACU

ACU

SMA

S

Clock

Power

802.3port

802.3port

LT module LT module

Page 12: Alu 7302 Isam

12

XD shelf types

Ø ISAM 7302 - XD§ XD-LT ALTS-T

ETSI shelf for 16 line boards (48 lines)

§ XD-SP ASPS-AETSI splitter shelf with backplane for 16 splitter boards (48 lines)

§ XD-SP ASPS-C16 slot ETSI splitter shelf without backplane for 16 splitter boards (48 lines)

Ø ISAM 7330 FTTN - XD§ XD-ARAM-D

mini-RAM shelf for 4 line boards (LT 48 lines)

Ø REM-XD§ EREM-A

1XD-LT – 24 ports VDSL and 1 XD-PScan be connected to 7330 FTTN XD or FD

Page 13: Alu 7302 Isam

13

XD equipment practice

Ø Single-shelf ASAM equipment practice § XD-LT ETSI splitterless shelf

ALTS-T

Ø Mounted in ISAM XD RACK (with TRU)§ LEDs

§ power:incoming from office battery

outgoing to shelves

Ø Different rack configurations§ splitterless deployment

Max 2 shelves per rack

2 ISAM systems per rack

§ Deployment with splitters integrated in rack1 shelf per rack

1 ISAM system per rack

TRU

SUB 2

SUB 1

splitterless deployment

Page 14: Alu 7302 Isam

14

XD rack configurations

splitterless deployment2 ISAM systems in 1 rack

TRU

splitterlessshelf 1

splitterlessshelf 2

dust filter

TRU

splitterlessshelf 1

dust filter

splitterless deployment1 ISAM systems in 1 rack

combo deploymentsplitters integrated in rack

TRU

splittershelf

splitterlessshelf

dust filter

Page 15: Alu 7302 Isam

15

Dust filter

ALTS-T – Line terminating shelfA

CU

LTLT LT LT LT LT LT LT LT LT LT LT LT LT LTNT

connectorarea

line boardarea

fan area

ISAM NT I/ON

T

AC

U

SMAS

Fan unit

PWR

LT

XDSL x 24

LT board

Back panel

LINE(1..24)

LINE(25..48)

FANdust filter

XDSL x 24

Page 16: Alu 7302 Isam

16

Other system components

top rack unit

Up to 2 XD LT shelves per rack

splitter shelf can be integratedin rack or separate (as shown)

ATRU-Q

• power provisioning• fuses for boards/fans

air flow

XD LT shelves

Fan unitsAFAN-H

• with or without dust filter

Page 17: Alu 7302 Isam

17

ECNT – Network termination board – XD (1/2)

Ø service hub § 24 Gbps line rate capacity§ 16 port reserved for line cards &

expansions§ 1 (0) port to the control & mgt function§ 7 (8) ports remaining for Ethernet user

links, subtending links and network links

Øcontains FLASH, RAM and ROM memoryØ interfacing with management and

control interfaces via backpanelØ traffic management on NT

ECNT-AECNT-C

Page 18: Alu 7302 Isam

18

ECNT – network termination board – XD (2/2)

LEDs

Op

tica

litf

sEl

ect

rica

l it

fs port

0:

op

tica

l or

ele

ctri

cal

port

1,2

,3 à

op

tica

l

ECNT-A: 3 Ethernet interfaces§ 2 variants: 100 Mb or 1Gb to each LT§ RJ45 auto-sensing 10/100/1000Base-T§ On board media conversion to GE optical§ SFP optical modules required§ Flash memory is 256 M

ECNT-C: 4 Ethernet interfaces§ 3 x 1Gbps SFP port§ 1 x 10/100/1000Mbps port electrical or

1Gbps optical§ Flash memory is 512 M

Ø ECNT is used in:§ 7302 ISAM XD§ 7330 ISAM FTTN XD

Page 19: Alu 7302 Isam

19

NT I/O – Network termination I/O board

Ø provides 4 additional (external) Ethernet interfaces

Ø ECNC-A§ RJ45 auto-sensing 10/100/1000Mbps

§ Or optical interfaces (1G only)

Ø ECNC-B§ FE optical interfaces

Ø SFP optical modules required

Ø RJ45 for test access (connection to TAU)

Page 20: Alu 7302 Isam

20

EBLT – MultiDSL line termination board

Ømulti-ADSL line card§ 48 ports per card

§ ADSL/ADSL2/READSL2/ADSL2+ line termination

§ POTS and ISDN line cards

Ø GE interface towards NT

Ø ATM cell <-> Ethernet packet conversion§ Inter Working Function (IWF)

Ø L2 and L3 cards§ difference in supported FW Models, QoS,...

EBLT-C-E (POTS, L3) EBLT-D-F (ISDN, L3)EBLT-J (POTS, L2)…

Page 21: Alu 7302 Isam

21

EVLT – VDSL line termination board

Ø VDSL line card§ 24 ports per card

§ POTS and ISDN line cards

Ø GE interface towards NT

EVLT-C (ETSI/POTS)EVLT-D (ETSI/ISDN)

Page 22: Alu 7302 Isam

22

SMLT – SHDSL line termination board - XD

Ø SHDSL line card§ symmetric service:

bit rate from 192 kbps to 5696 kbps

à in steps of 64 kbps

§ 24 ports per card

§ EFM or ATM/IMA

Ø GE interface towards NT

SMLT-J

SMLT-K

Page 23: Alu 7302 Isam

23

ACU – Alarm Control Unit in 7302 ISAM XD

Ø inserted in the leftmost slot of the splitterless shelf (ALTS-T)

Ø five LED’s to indicate different levels of fault conditions§ ACO/lamp test push button switch

Ø craft interface § 9-pin D-connector

Ø Ethernet connection § RJ-45 for out-band mgmt

§ cannot be used

Ø one ACU/ISAM system

AACU-C

Page 24: Alu 7302 Isam

Alcatel-Lucent University Antwerp 24

University

Equipment Practice - FD

Flexible Density

Page 25: Alu 7302 Isam

25

ISAM FD shelf – Flexible Density Equipment Practice

Ø FD slots are universal: can hold LTs as well as splitters

Ø Higher densities can be obtained with FD shelves § One rack may contain 3 FD shelves compared to only 2 XD shelves

Ø Various FD splitters will be availablemultiDSL and VDSL2

POTS-only and universal POTS/ISDN

Mul

ti-A

DS

L

VD

SL2

PO

TSIS

DN

fiber

(p2p

Eth

)

split

ters

Multiple flavors of line cards availableMultiple density variants (28p, 48p)

Single shelf for all deployments

•DSL•voice•fiber

Page 26: Alu 7302 Isam

26

General architecture 7302 ISAM-FD

Ø new equipment practice – NEP§ NFXS-A

Ø capacity = 16 + 2 line slotsNT-B/NTIO slots can be used as line slot

Ø universal slot concept§ shelf can accomodate any mix of

xDSL LTs, splitters, fiber LTs, voice cards

Ø aggregation (service hub) and control- & management function integrated on NT

Ø 1GE connectivity between NT and LT via backpanel§ Backplane ready to support evolution

to higher densities

Ø ACU & clock function integrated on NT board

Ø SMAS functionality integrated on backpanel

7302 FD-shelf

ASAM link

Control link

NT

Aggregation function (SHUB)

1 …16/18 GE2 GE

1..6 GE2 External Ethernet links

Control/Mgtfunctions ACU Clock

6 External Ethernet links

LT16à 18or SP16à 18ormixed

SMAS

NTIO 802.3port

802.3port

Power

Page 27: Alu 7302 Isam

27

Shelf types – FD equipment practice

Ø ISAM 7302 - FD§ FD -NFXS-A

ETSI shelf for 16/18 boards (x lines)universal slot concept allows any mix of xDSL LTs, splitters, fiber LTs,

voice cards

Ø ISAM 7330 FTTN - FD§ FD-NFXS-B

Mini-RAM ETSI shelf for 8/10 boards (x lines)universal slot concept allows any mix of xDSL LTs, splitters, fiber LTs,

voice cards

Ø 7356 FTTB REM - FD§ FD-NFXR-A

can be connected to 7330 FTTN XD or FD.

Page 28: Alu 7302 Isam

28

7302 ISAM–FD shelf: NFXS-A

Ø No connector area: direct front access cabling

Ø 2 NT slots + 1 NTIO slot

Ø 16 “LT/splitter” slots

Ø Capacity = 16 + 2 line slots§ NT-B/NTIO slots can be used as

line slot

§ Max 864 lines/shelf

500 W x 600 H x 280 D

600

LT/splitter slots LT/splitter slots2 x NT + NTIO

FAN

Page 29: Alu 7302 Isam

29

7302 ISAM–FD shelf: NFXS-A

Card cage area

DSL

LT board

Back panel

FANdust filter

LT LT LT LT LT LTLT LT LT LT LT LT LT LT LTLT

NTA

NTB

/LT

NTI

O/L

T

Power & connectorarea

PWRDust filter

Fan unit

fiber conduct

Fan area

fiber channel

fiber conduct

Page 30: Alu 7302 Isam

30

7302 ISAM-FD shelf – configurations LT shelves

XDSL cable management area

48p -

LT

Fan unit

48p-

LTNT

NT

IO

TAUBITS

Craft

BITS

Craft

Mgt

SFP4

SFP1

SFP5

SFP6

SFP7

SFP8

SFP3

SFP2 SFP2

NT

Mgt

SFP1

AD

SL 1

-48

connectorarea

BAT filersInletBlock

CBsLamps

connectorarea

PWR filtersPWRInletBlock

CBsLEDS

fiber management areaFan unit

BPA

XDSL cable management area

48p -

LT

Fan unit

48p-

LTNT

NT

IO

TAUBITS

Craft

BITS

Craft

Mgt

SFP4

SFP1

SFP5

SFP6

SFP7

SFP8

SFP3

SFP2 SFP2

NT

Mgt

SFP1

AD

SL 1

-48

connectorarea

BAT filersInletBlock

CBsLamps

connectorarea

PWR filtersPWRInletBlock

CBsLEDS

fiber conduct areaFan unit

BPA

FD CO 16 slot LT shelf with NT redundancy

FD CO 18 slot LT shelf no NTIO / no NT redundancy

(e.g. HSI only application)

XDSL cable management area

48p-

LT

Fan unit

48p-

LTNT

NT

IOTAUBITS

Craft

BITS

CraftMgt

SFP4

SFP1

SFP5

SFP6

SFP7

SFP8

SFP3

SFP2 SFP2

NT

Mgt

SFP1

AD

SL 1-

48

connectorarea

BAT filersInletBlock

CBsLamps

connectorarea

PWR filtersPWRInletBlock

CBsLEDS

fibermanagement areaFan unit

BPA

XDSL cable management area

48p-

LT

Fan unit

48p-

LTNT

NT

IOTAUBITS

Craft

BITS

CraftMgt

SFP4

SFP1

SFP5

SFP6

SFP7

SFP8

SFP3

SFP2 SFP2

NT

Mgt

SFP1

AD

SL 1-

48

connectorarea

BAT filersInletBlock

CBsLamps

connectorarea

PWR filtersPWRInletBlock

CBsLEDS

fiber conduct areaFan unit

BPA

XDSL XDSL

Page 31: Alu 7302 Isam

31

7302 ISAM FD shelf – configurations LT/splitter shelf

FD CO 16 slot shelf with NT redundancy

48p-

LT

Fan unit

48p-

LTNT

NT

IO

TAUBITS

Craft

BITS

Craft

Mgt

SFP4

SFP1

SFP5

SFP6

SFP7

SFP8

SFP3

SFP2 SFP2

NT

Mgt

SFP1

AD

SL

1-48

Connectorarea

BAT filersInletBlock

CBsLamps

Connectorarea

PWR filtersPWRInletBlock

CBsLEDS

Fiber management areaFan Unit

BPA

POTSLINE

XDSL

LT SP LT SP

48p-

LT

Fan unit

48p-

LTNT

NT

IO

TAUBITS

Craft

BITS

Craft

Mgt

SFP4

SFP1

SFP5

SFP6

SFP7

SFP8

SFP3

SFP2 SFP2

NT

Mgt

SFP1

AD

SL

1-48

Connectorarea

BAT filersInletBlock

CBsLamps

Connectorarea

PWR filtersPWRInletBlock

CBsLEDS

Fiber management areaFan Unit

BPA

POTSLINE

XDSL

LT SPLT SP LT SPLT SP

FD CO 18 slot shelf without NT redundancy

Page 32: Alu 7302 Isam

32

NANT - Combined NT unit

Ø service hub § 24 Gbps line rate capacity

§ Supports i.f.o setup/configurationUp to18 LT cards

Up to 8 ports for Ethernet user links, subtending links and network links

Up to 12 ports for expansion links

i.f.o available links on NTIO board

Ø contains FLASH, RAM and ROM memory

Ø interfacing with management and control interfaces via backpanel

Ø traffic management on NT

Ø ACU module integrated on NT

NANT-A

Page 33: Alu 7302 Isam

33

NANT-A - Combined NT unit version A

Ø NANT à used in:§ 7302 ISAM FD§ 7330 ISAM FTTN FD

Ø 1 Craft interface (RJ45)Ø 1 BITS interface (RJ45)

§ Availability I.f.o variant

Ø 1 100BaseT outband Mgt interface§ Not used at the moment

Ø 2 ports for user/network/subtending links § 1 GE Optical SFP and § 1 switchable GE Optical SFP/RJ-45

Ø Flash memory is 512 M

RJ45 BITS (AB variant only)

RJ45 Craft

RJ45 Outband Managemen (LOM)

RJ45 Uplink 1

SFP Uplink 1

SFP Uplink 2

switchable

Page 34: Alu 7302 Isam

34

NCNC - NT I/O Applique version B

Ø6 optical GE Eth interfaces to the active NT board.

Øserial TAUS interface to the TAU board.

ØEnvironment Monitoring interface to communicate with a monitor box over a RS-232 link.

NCNC-B

Page 35: Alu 7302 Isam

35

NALT – MultiDSL Line Termination Unit

Ø multi-ADSL line card§ 48 ports per card§ ADSL, ADSL2, ADSL2+, READSL and

Annex M§ POTS and ISDN line cards

Ø Front access connector on the LT board.

Ø GE interface towards NTØ ATM cell <-> Ethernet packet

conversion§ Inter Working Function (IWF)

Ø L2 and L3 cards§ difference in supported FW Models,

QoS,...NALT-B (POTS, L2, 48 ports) NALT-C (POTS, L3, 48 ports)NALT-D (ISDN, L3, 48 ports)…

Page 36: Alu 7302 Isam

36

NSLT – SHDSL Line Termination unit

ØSHDSL line card§ symmetric service:

bit rate from 192 kbps to 5696 kbps

à in steps of 64 kbps

§ 24 ports per card

§ EFM or ATM/IMA

ØGE interface towards NT

NSLT-A 24 SHDSL

Page 37: Alu 7302 Isam

37

NVLT – VDSL(2) Line Termination unit

ØVDSL line card§ 24 or 48 ports per card

§ POTS and ISDN line cards

ØSupport VDSL(2) and ADSL(2+)

ØGE interface towards NT

NVLT-A 24 VDSL(2) POTS

NVLT-B 24 VDSL(2) ISDN

NVLT-C 48 VDSL(2)-ADSL(2+) POTS

NVLT-D 48 VDSL(2)-ADSL(2+) ISDN

Page 38: Alu 7302 Isam

38

www.alcatel-lucent.com