    ALSPA Care System

    Shaft Vibration

    Data Acquisition Unit

    Datasheet

    FEATURES Shaft Vibration Data Acquisition Unit (DAU) Part number: AC8010

    Reference ALSTOM Ordering Information: AXX -BXX-CXX-DXX

    A: Qty. of Tachophasor channels (Max. 8 channels)

    B: Qty. of Vibration Channels (Max. 48 channels)

    C: Qty. of Static Channels (Max. 24 channels)

    D: Sampling method(01: Sync / Async, 02: Sync & Async)

    Mechanical Chassis 19, 3U high

    Construction Dimensions 134mm x 451mm x 484mm (H x W x D)

    Weight 12.6 kg

    Protection IP 50

    Power

    Requirements

    Operating Voltage 100 VAC 240 VAC, 50 60Hz

    Wattage Max. 60 W

    Shaft Vibration Data Acquisition Unit - AC8010

    The Data Acquisition Unit (DAU) is part of the

    ALSPA Care Shaft Vibration Monitoring and

    Diagnostic System. It samples the signal inputs

    such as rotating speed, vibration, process

    signals, converts them from analog to digital and

    transfers the data to ALSPA Care Server.

    Type AC8010 is designed for Thermal Power.

  • 7/23/2019 ALSPA SV System Datasheet

    2/3

    ALSTOM 2012. All rights reserved. The ALSTOM logo and any alternative version thereof are trademarks and service marks of ALSTOM. Theother names mentioned, registered or not, are the property of their respective companies. Information contained in this document is provided without liability

    for information purposes only and is subject to change without notice. No representation or warranty is given or to be implied as to the completeness of

    information or fitness for any particular purpose. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited.

    ALSTOM Power PAC Power Automation & Controls - Helpdesk: [email protected]/3 POWER|ABC

    Shaft VibrationData Acquisition Unit

    Doc3324 en Rev

    Communication COM1 D-sub 9 for DAU setup

    COM2 D-sub 9, RS232, Baud rate: Max. 19.2kps

    Modbus communication with control system to obtain process data

    TCP/IP 1 x RJ45, 10/100 Base-TX

    Communication with ALSPA Care server for transmit data

    Data Upload Upload Rate to Server Max. once per second

    Bandwidth Requirement Min. 2 kbps/channel

    Data Buffering Capacity 1GB / 30 days average, automatic uploading on recovery

    Tachophasor Input Number of Channels Max. 8 channels

    Speed Range 36 59999 rpm

    Input Resistance 400 k

    Input Range 25 V DC

    Measuring Error 1.5 rpm

    Trigger Voltage Threshold 0.2 V / 0.4 V / 0.6 V / 0.8 V / 1.0 V / 1.2 V / 1.4 V / 1.6 V

    1 V / 2 V/ 3 V / 4 V / 5 V / 6 V / 7 V / 8 V

    Dynamic Input Number of Channels Max. 48 channels in Type I mode(synchronous / asynchronous)

    Supported Vibration Signals Displacement / Velocity / AccelerationInput Resistance 400 K

    DC Input Range 20 V DC

    AC Input Range Max. 4 V / 400mV

    DC Measuring Error

  • 7/23/2019 ALSPA SV System Datasheet

    3/3

    ALSTOM 2012. All rights reserved. The ALSTOM logo and any alternative version thereof are trademarks and service marks of ALSTOM. Theother names mentioned, registered or not, are the property of their respective companies. Information contained in this document is provided without liability

    for information purposes only and is subject to change without notice. No representation or warranty is given or to be implied as to the completeness of

    information or fitness for any particular purpose. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited.

    ALSTOM Power PAC Power Automation & Controls - Helpdesk: [email protected]/3 POWER|ABC

    Shaft VibrationData Acquisition Unit

    Doc3324 en Rev

    Data Processing Sampling Speed Max. 2048 samples per revolution

    A / D Resolution 14 bit

    Spectrum Lines Max. 6400

    FFT Windowing Rectangular

    Hanning

    Hamming

    Triangular

    Bartlett

    Blackman

    Flat top window

    Exponential window

    Service Diagnostics LEDs (power, self-check, Ethernet link status, com1 link status, com2

    link status )

    Environment Temperature Operating: 0 C ... 5 C

    Storage: -40 C ... 80 C

    Relative Humidity 0% 95%(no condensation)

    Standards and

    Certifications

    EN 61326-1: 2006 Electrical equipment for measurement, control and laboratory use-

    EMC requirements Part 1: General requirements.EN 61010-1: 2010 Safety requirements for electrical equipment for measurement, control

    and laboratory use Part 1: General requirements

    FCC Part 15 Subpart B:

    2011

    Radio frequency devices-unintentional radiators

    Shock 10 gn for 11ms

    Vibration 3.5 mm/peak (5 ... 9 Hz)