Allplan 2014 IFC Workflow

download Allplan 2014 IFC Workflow

of 16

Transcript of Allplan 2014 IFC Workflow

  • 8/9/2019 Allplan 2014 IFC Workflow

    1/16

    Allplan 2014 workflow for exporting the data to the external energy analysis tool

    0 Test case

    I New document settings

    1. Create new project, set the defaults

  • 8/9/2019 Allplan 2014 IFC Workflow

    2/16

    Allplan 2014 workflow for exporting the data to the external energy analysis tool

  • 8/9/2019 Allplan 2014 IFC Workflow

    3/16

    Allplan 2014 workflow for exporting the data to the external energy analysis tool

    Building structure is used as opposite to Fileset structure, because Building structure is used for IFC export. But the

    File set structure can also be used and then copied to the Building structure before the export.

    I Wall layers settings

    One-layered wall

  • 8/9/2019 Allplan 2014 IFC Workflow

    4/16

    Allplan 2014 workflow for exporting the data to the external energy analysis tool

    2. Multi-layerd wall, maximum number of layers is 5. So my wall should be adjusted

    2a. Properties are adjusted

  • 8/9/2019 Allplan 2014 IFC Workflow

    5/16

    Allplan 2014 workflow for exporting the data to the external energy analysis tool

    3. Once I have the concept, I start with Parameters, Attributes part. Setting the thickness. But it is unclear what units

    are used for the thickness. Meters? Mm? Cm? It only becomes clear while specifying the parameters in the different

    window for the layers, see step 4.

    The previously created wall favourite is used.

  • 8/9/2019 Allplan 2014 IFC Workflow

    6/16

    Allplan 2014 workflow for exporting the data to the external energy analysis tool

    4. Otherwise it is probably easier to use the Attributes button where the parameters for each layer can be set

    The attributes can be assigned to the whole wall or to one layer. Only Lambda can be specified from the thermal-related

    properties. U-value is not needed for the simulation.

    NB for IFC: the units in these windows are different IFC takes the mm.

  • 8/9/2019 Allplan 2014 IFC Workflow

    7/16

    Allplan 2014 workflow for exporting the data to the external energy analysis tool

    I Slab settings

    5. Only single-layered slabs can be created

  • 8/9/2019 Allplan 2014 IFC Workflow

    8/16

    Allplan 2014 workflow for exporting the data to the external energy analysis tool

    I Roof settings6. Roof can be up to 5 layers thick

    So the roof structure is also simplified

  • 8/9/2019 Allplan 2014 IFC Workflow

    9/16

    Allplan 2014 workflow for exporting the data to the external energy analysis tool

    7. And then created in Allplan, saved as favourite DAl 01 b Holzsparren-Steildach

    7a. Additional properties can be assigned to the Roof layers via Right mouse click on the object (roof) > Assign, Modify

    object properties > window with properties

  • 8/9/2019 Allplan 2014 IFC Workflow

    10/16

    Allplan 2014 workflow for exporting the data to the external energy analysis tool

    8. The height of the outside wall layer remains 4.2, all the others are changed to the 3.65 m

    I Custom IFC parameters

    9. Custom parameters can be created and assigned to the layers. Then they are exported to the IFC

  • 8/9/2019 Allplan 2014 IFC Workflow

    11/16

    Allplan 2014 workflow for exporting the data to the external energy analysis tool

    The custom parameters however are not saved neither in the material nor in the favourites, so they should be specified

    each time separately for all building elements.

    II Export to IFC

    Allplan 2014 exports 2x3 IFC and 2x3 IFCxmls

    1. got the error

    2. Changed the Building structure and picked it up at the export

  • 8/9/2019 Allplan 2014 IFC Workflow

    12/16

    Allplan 2014 workflow for exporting the data to the external energy analysis tool

    Different export options can be specified for the export

  • 8/9/2019 Allplan 2014 IFC Workflow

    13/16

    Allplan 2014 workflow for exporting the data to the external energy analysis tool

    3. Exported IFC and IFC xml for reviewing

    4. If the wall layers have different heights, IFC is written with errors. Sketchup does not import anything but a slab.

    (Imported to the Sketchup via IFCtoSU plugin)

  • 8/9/2019 Allplan 2014 IFC Workflow

    14/16

    Allplan 2014 workflow for exporting the data to the external energy analysis tool

    4. The wall layers are all set to 3,65, this way Sketchup imports the walls and the slab. But not the roof, window anddoor.

  • 8/9/2019 Allplan 2014 IFC Workflow

    15/16

    Allplan 2014 workflow for exporting the data to the external energy analysis tool

    5. Roof is only imported if it consists of one layer

    Physical properties: 1. Only the properties of the outer layers of the complex structures are exported, Lambda values of

    0.21 and 0.84, which correspond to the Dachziegel Ton and Gipskartonplate

    IFCxml fragments with material properties

  • 8/9/2019 Allplan 2014 IFC Workflow

    16/16

    Allplan 2014 workflow for exporting the data to the external energy analysis tool

    FZK viewer

    IfcMaterialLayerSet is not specified, presumably this is the reason why the layer properties are not exported properly