Alien Technology Portal Solution – ALX-9000 Series
Featuring the ALR-9800 and ALR-9780EPC Gen 2 RFID Readers
ALIEN TECHNOLOGY CONFIDENTIAL 2
Alien Technology Portal Solution
• Quick, low cost installation• No antenna placement issues
• No coax cabling over/around dock door
• Swap-out capability avoids risk of down time
• Complete dock door requirements in one package• Reader and antennas
• LAN, or WLAN option
• Support for light stack and electric eye presence detection
• Rugged, steel design
• Dust and splash-resistant
ALIEN TECHNOLOGY CONFIDENTIAL 3
Rugged Design
• Rugged steel construction
• IP54 moisture and dust protection
• UHF-transparent, heavy-duty plastic facing
• LAN and power inputs enter via standard electrical conduit on top of unit
• Optional, 7”replaceable fence around base protects tower from equipment bumps at floor level (not shown)
ALIEN TECHNOLOGY CONFIDENTIAL 4
Complete RFID Feature Set
• Industry-leading RFID performance options• ALR-9800 Enterprise RFID Reader – expandable, scalable
• ALR-9780 C1-Gen 2 Reader – excellent C1 performance
• ALR-9800• Protocol agile: EPC C0/0+, C1, Gen 2; future expandability
• Exceptional mixed-population performance
• Enterprise ready; manageable, configurable, reliable
• Multiple dense reader management tools including DRM
• Low initial cost: Multistatic antennas & enhanced GPIO
• Expandable platform for enhanced edge intelligence
• ALR-9780 • Most popular, highly interoperable, EPC Class 1 reader; C1G2 upgradeable
• Network-ready, plug and play design
• Extensive, configurable autonomous mode options
ALIEN TECHNOLOGY CONFIDENTIAL 5
ALR-9xxx-PRT Portal Base Models
ALX-9000Cabinet only
ALR-9800 models
ALR-9802-PRTL
ALR-9802-PRTC
ALR-9804-PRTL
ALR-9804-PRTC
ALR-9782-PRTL
ALR-9782-PRTC
ALR-9784-PRTL
ALR-9784-PRTC
Single-Sided
Dual-Sided
ALR-9780 models
ALIEN TECHNOLOGY CONFIDENTIAL 6
Portal Option Description
802.11 g Wireless BridgeLinksys WET54 v.2
Mounts behind reader; antenna on top of unitPlugs into reader RJ45 LAN jack
Light StackAllen Bradley 855T Series
3 lights plus base, bayonet mountcontrolled by GPIO Ordered with horn
Requires 4 ALX-9010 relays when used with ALR-9780
HornMallory Sonalert
Mounted to side of unitControlled by GPIO
Ordered with light stackRequires 4 ALX-9010 Relays when ordered with ALR-9780
Electric Eye Presence DetectorAllen-Bradley MiniSight Retroflective 5m
With reflectorInput connects to reader GPIO signalProtective Fence
7” high steel fence offering protectionfrom glancing blows at floor level
Uses same mounting holes as base plate(not pictured)
ALX-9001-PRT
ALX-9004-PRT
ALX-9002-PRT
ALX-9003-PRT
ALX-9010-PRT
Relay KitFour of these are required when the ALR-9002-PRT is ordered with the ALR-9780. Not required with the
ALR-9800.
ALIEN TECHNOLOGY CONFIDENTIAL 7
Portal Option Ordering Information
ALX-9001-PRTProtective fence. 7-inch tall steel barrier that protects the ALX-9000 from floor-level impacts.
ALX-9002-PRT
Lightstack and horn. 3-color light stack mounts on top of portal unit. Horn emits audible signal. Light stack and horn triggered by reader I/O signals. Power supply included.
ALX-9003-PRT
Photo eye presence detector. Detects presence of pallet or other object in front of the portal and provides digital signal to reader via GPIO input. Uses included reflector mounted opposite portal.
ALX-9004-PRT802.11b/g Wireless LAN. Wireless LAN Bridge mounts inside of portal tower and connects to reader RJ45 Ethernet connector. Antenna mounts on top of tower.
ALX-9010-PRTRelay kit. Required to implement light stack or horn with ALR-978x-PRT portals. Includes one relay.
ALIEN TECHNOLOGY CONFIDENTIAL 8
Support
• Training in industry-leading Alien RFID Academy
• After-sale service plan options• Extended warranty available
• Repair/replacement service level options avoid downtime
• Firmware upgrade license
• Alien on-site, expert RFID design services
• RFID lab services• Testing on portal, conveyor or
palletizer systems
• Optimal product tagging
ALIEN TECHNOLOGY CONFIDENTIAL 9
Specifications
Protocol support EPC Class 1, Class 1 Gen 2, EPC Class 0, 0+*
Temperature Operation.: -20* to 50 C; Storage: -20 to 70 C
RF Output 902-928 MHz, 1 Watt
LAN Ethernet, Internet Protocol, optional 802.11g
Construction 150 mil steel; plastic faceplate
Dust and Moisture IP54
Power 110VAC, 50-60 Hz
Safety UL 69050*, CSA 22.2/60950* (pending)
Emissions FCC 47 CFR Part 15, Canada RS210
Dimensions 84’ x 11” x 18”; baseplate: 12” x 24”
*ALR-9800 only; see reader data sheets
ALIEN TECHNOLOGY CONFIDENTIAL 10
IP54 – Water and Dust Protection
Definition: Water splashes on to the enclosure from any direction must not have any harmful effects.
Test conditions: The enclosure is tested by means of a spray head or a flushing pipe which is aimed at it from all sides according to the standardized testing time / volume flow.
Conditions for acceptance: Should water have penetrated, it must not- be present in quantities which impair the good working order of the operating material or represent a safety hazard;- deposit on non-conducting parts where it could lead to creep currents; - come in contact with live parts or coils which are unsuitable for operating in wet conditions; - collect near the wire end or possibly penetrate the wire.
Definition: Dust penetration is not prevented altogether, but dust must not enter in sufficient quantities to prevent the equipment from operating satisfactorily, or to impair safety.
Test conditions: The test is carried out in a dust chamber in which talcum powder is being kept suspended in the air by means of a dust distributor or similar device. The enclosure which is being tested is placed in the test chamber while a vacuum pump keeps the pressure in the enclosure below the atmospheric pressure of the environment according to the standard.
Conditions for acceptance: The protection is satisfactory if the inspection shows that talcum powder has not accumulated in places or in quantities in a way that could impair the good working order of the operating material or represent a safety hazard, regardless of the type of dust concerned.
Water
Dust