Challenge
Demonstrate an implementable product that provides multiple capabilities to producing assets that will:
Enhance Safety for Field personnelMonitor emissions for Safety notification and Regulatory requirementsProvide archived performance and compliance metricsIntegrate into the Control System and Control System PhilosophyShut down critical equipment with crisis emission event encounteredOperate to – 45oF
Solution
ALERT PLUS, LLC
Matt Murdock, Chief Operating Officer
Pinedale, WY 82941
(307) 749-0615
Alert Plus Aegis 400 Remote Emission Monitoring Station
AG
END
AAgenda Coverage
Aegis 400 Remote Monitoring emissions stationProduction Resource Coverage ; Production Supply ChainProduction problem the Aegis solvesMethod alignment with existing compliance methodsExisting Regulatory Compliance and trendsExisting Oil and Gas Methods that Aegis attainsSafety and operations benefitsROI categories for Aegis implementationWork Process Summary of Aegis; implementation andoperationsAegis shutdown technologySummary
UP
STREA
MTO
DO
WN
STREA
M
Up and Down the Supply and Production Stream
Where does the Aegis 400 provide benefit ?
TH
EP
RO
BLEM
& TH
EA
LERT
PLU
SS
OLU
TION
Problem: Monitor and manage fugitive emissions that mitigateoperation, production loss, and safety risk.
Solution:Aegis 400 detects excessive emission events, logs it, andactivates alarms to stakeholdersSite assets shut down if factored in alarm/operationphilosophy.SOP is preserved with data log and data analytics accessCost effective. Fund it with Control System budgetDemonstrable as risk monitoring and assessment resource forRule 49 related operations
A SU
MM
AR
YO
FR
EGU
LATO
RY
INFLU
ENC
ES
The Regulatory Management Challenge:
What are existing and evolving requirements and howto factor into Operations implementation
TH
EP
RO
BLEM
& TH
EA
LERT
PLU
SS
OLU
TION
Methane and VOC Emission Sensing
Both Wyoming and Colorado lead to set regulatory andperformance requirementsLDAR at compressor stations and production facilitiesMethod set to identify high emission assets and develop aprogram to mitigate itSuccinct process to assess emission leaks and resolve themStorage Tank Emission Management (STEM) with remoteemission monitoringLeak repair response and recordkeepingProducers have a good knowledge base of where high emittersare in the systemEmphasis on risk assessment and management
*Some content from Mike Silverstein, Colorado Department of Public Health and Environment
TH
EP
RO
BLEM
& TH
EA
LERT
PLU
SS
OLU
TION
Methane and VOC Emissions - Trends
Other states are establishing emission performance rules: OH,WY, CAColorado methods are akin to a Best PracticeEPA has just released NSPS0000a. Ratification is gearedtowards 2016CTG is released for ozone attainment initiativesThe impetus for emission management is risk assessment andthe risk mitigation plans to protect.Site based solutions that provide continuous monitoring, alert,mobile accessibility, and archival knowledge base harmonizewell with evolving and present regulations
*Some content from Mike Silverstein, Colorado Department of Public Health and Environment
EX
ISTING
OP
ERA
TION
SM
ETHO
DS
Integrity Management. Aegis is a tool to fulfillTitle 49 CFR Part 192 (Gas operations)
Established management method for operational risk assessment setby DOT/PHMSA for Midstream.The Risk assessment philosophy can be applied to ProductionoperationsApply the existing precedent for risk based methods to Safety andEmissions management criteriaLifecycle management drives the need for operational risk review.Regular risk review and mitigation (yearly)Objectives• To perform integrity assessments of pipelines in locations where a pipeline
failure could have significant adverse consequences (referred to as HighConsequence Areas or HCAs).
• To improve operator management, analytical, and operational processes tomanage pipeline integrity.
• To increase government’s role in the oversight of operator integritymanagement programs and activities.
• To improve public confidence in pipeline safety.http://primis.phmsa.dot.gov/comm/IM.htm?nocache=8834
EX
ISTING
OP
ERA
TION
SM
ETHO
DS
Integrity Management. Aegis is a tool to fulfill
Title 49 CFR Part 192 (Gas operations) (Taken directly from the Rule)
This is Where the Risk Analysis Program Element Comes InComprehensive and systematic risk analysis is a valuable tool to helpoperators identify and determine the significance of previouslyunrecognized threats. Through rigorous analysis of all available data,pipeline operators are required to identify and evaluate all potentialprecursors to pipeline failure and the risks that they pose. Operatorsmust also identify and implement additional preventive or mitigativemeasures to address the most significant threats identified by the riskanalysis. These measures would be dependent on the nature of thethreat and the specifics of the operator’s pipeline system and itsoperation. Some examples include: enhancing damage preventionprograms; improving corrosion control monitoring; enhancing controlcenter operator training; improving leak detection system capability;conducting emergency drills with local emergency responders; andinstalling remotely operated valves to expedite the isolation of a leak orfailure when one is discovered.
http://primis.phmsa.dot.gov/comm/IM.htm?nocache=8834
TH
EP
RO
BLEM
& TH
EA
LERT
PLU
SS
OLU
TION
Integrity Management. Aegis 400 as an Alarm Alert
ANSI/ISA 18.2 Alarm Management Life-cycle
Emissions Remote Monitoring extends Alarm Management toproduction assets to extend integrity management.Operations unify Control and Situation assessmentAdditional Stake holders provide for comprehensive situationassessment
TH
EP
RO
BLEM
& TH
EA
LERT
PLU
SS
OLU
TION
Problem: Field emission events create safety threats forField Personnel and communities
Solution:Emission events alert Control Operations and ManagementResponse team is able to be alerted remotelyService Team can check emission levels before entering siteAll response actions are able to be logged, linked to the event,and recorded in data archive
GA
IND
ATA
FOR
STA
KE
HO
LDER
SRemote Emission and Safety Triage
System level Alert that drives SOP responseRemote access to incident data to drive priority and resourcedecisionsField personnel access emission levels to determineaccessibility to site for service
Crisis Management,
Operations Improvement,
Emergency Response Team
Operations Management
Field Operations
EmissionsOr
Safety Alert
GA
INA
DD
ITION
AL
BEN
EFITSW
ITHA
EGIS
Proactive Safety Management for Field Emission risks
Demonstrate this to any and all stakeholders as risk mitigation.Gain visibility to Community and Compliance efforts with theinvestmentEvidence of strong company commitment for stewardship
Emission and safety
incident avoidance
Production Operations
Stewardship to community
and lands
Demonstrable archive of
performance
TH
EP
RO
BLEM
& TH
EA
LERT
PLU
SS
OLU
TION
Problem: How is the Aegis 400 an incremental assetmonitoring resource to present resources ?
Solution:
Aegis 400 is a networked, fixed emission monitoring systemInstantaneous alarm alert notification to stake holders andcontrol operationsAegis product philosophy is compatible with ControlPhilosophy (alarm and event driven action SOP)Data log provides an operations work response archive
HO
WTO
PA
YFO
RA
EGIS
40
0Return on Investment Opportunities for the Aegis 400
Economically PricedEfficient implementationIntegrate-able with existing assets andcontrol systemsWork Process improvementLoss recoverySafety incident avoidanceRegulatory issue avoidanceDemonstrable as good faith investmentfor Community and BLM
IMP
LEMEN
TATIO
NO
FA
EGIS
40
0Implementation Work Process with the Aegis 400
Identify site emission coverage requirements
Power availability plan for site coverage
Estimate 2 Hours completion time for installation
Identify locational and resource elements and installation is completed quicklyDetermine if a stand alone monitoring station or connection to Control NetworkQuarterly calibration cycle – to integrate with other site based service requirementsSensors to be replaced at 2 – 5 year increments depending on sensor types
EFFIC
IENC
IESG
AIN
EDW
ITHA
EGIS
ALER
TSWork Process – Assessment and Incident Handling
Emission or Safety Alert
• Remote notification; alert through control network or broadcast
• Stake holders notification
• Trigger SOP (standard operating procedure)
Assess, Deploy
• Does SOP match the alert scope details ?
• Modify the response team to match the threat and incident scope
• Respond accordingly to the threat level alerted
Resolve, Document
• Team deployed matches the scope of the threat . Cost management
• Responsiveness matches the SOP outlined as is documented as such
• Archived alert, response, and closure. Lessons learned can be applied
This is a repeatable Integrity Management processProcess and response discipline is maintainedPotential ROI with dispatch of resources to match the data analysis of the threat alert
TH
EP
RO
BLEM
& TH
EA
LERT
PLU
SS
OLU
TION
Problem: Cold temperature operations are a challengefor monitoring conditions and operations
Solution:Aegis 400 is a networked, fixed emission monitoring systemOperating temperature range is -45oF to 150oFAlert Plus continues to characterize for even lower operatingtemperatures
Much of NG production exists in cold weather
regions
TH
EP
RO
BLEM
& TH
EA
LERT
PLU
SS
OLU
TION
Problem: There are other data collection resources anddevices at site locations. How to consolidate ?
Solution:Aegis 400 is a networked, fixed emission monitoring systemMultiple channels enable integration of multiple datacollectionThe Aegis 400 is a PLCProbe data is able to be integrated into channel data collectionon the Aegis 400
AU
TOM
ATIC
SH
UTD
OW
NShut down operations remotely or automatically
Proprietary valve provides “control & command”functionality in one package in extreme conditions.
SU
MM
AR
Y
Alert Plus Aegis 400
Remote Emission Monitoring Station
Cold Weather Operation to – 40oF
Automatic asset shut down triggered by alarmed emission event
Operation philosophy integrates with CRM and control operation philosophy
Can be integrated into Control system as a PLC
Utilize as continuous improvement compliance resource
Proactive solution to evolving emissions management standards
Practical implementation and investment cost
SU
MM
AR
Y
-45oC
Aegis 400 Operation Philosophy
PO Box 268; Pinedale, WY 82941Tel. (844) ALERTPLUS
Matt Murdock, Chief Operating OfficerCell: (307) 749-0615