Ald Maintenance Link Failure Alarm Tutorial
Click here to load reader
-
Upload
rv-salazar -
Category
Documents
-
view
822 -
download
196
description
Transcript of Ald Maintenance Link Failure Alarm Tutorial
ALD Maintenance Link Failure 26541
TROUBLESHOOTING GUIDE
ANTENNA LINE DEVICE COMPONENTS
REMOTE CONTROL UNIT
RET ANTENNA
AISG 2.0 CABLE
SMART BIAS TEE
TOWER MOUNTED AMPLIFIER
•OPEN LMT SOFTWARE• USER: admin• LMT IP: 17.21.2.15• PC IP: 17.21.2.10-18 • PASSWORD: NodeB
click
PRESS BROWSE ALARM TO SEE ALARM DETAILS
DOUBLE CLICK ALARM TO SEE DETAILED INFORMATION.
DOUBLE CLICK
Click Solution tab to get moreHelp on troubleshooting procedure.
SOFTWARE SOLUTION
HARDWARE SOLUTION
HOW TO DEAL WITH THE PROBLEM
DSP ANTCON
NOTE: Power Supply Port default value for N0A, N2A & N4A is always ON state.
SOFTWARE SOLUTIONIn MML command line type in
SOFTWARE SOLUTION
SET ALDPWRSW to OFF and then to ON Check results using DSP ANTCON.ON STATE: SMBT HAS CURRENT
CONSUMPTIONOFF STATE: SMBT HAS ZERO
CONSUMPTION
Reset ALD POWER SWITCH
IF in ON STATE THERE IS ZERO CURRENT CONSUMPTION AND/OR CANNOT SWITCH OFF AND ON the status, THEN SMBT /TMA IS DEFECTIVE.
SOFTWARE SOLUTION
Remove and Add the affected ALD. RMV ALD
Example Remove the ALD named 0_0N0A0RET_3G.RMV ALD: NAME ="0_0N0A0RET_3G";
ADD ALDExample
1. Regular installation scenario: Add a single RET antenna named 0_0N0A0RET_3G to antenna connector N0A in subrack 3 of cabinet 0 corresponding to sector 0 in NodeB site 0.ADD ALD: NAME="0_0N0A0RET_3G", CASE=REGULAR, DEVTP=SINGLE_RET, CN=0, SRN=3, ACN=N0A;
Use the command SCN ALD to verify ALD status after using RMV ALD and/or ADD ALD commands.
SOFTWARE SOLUTION
CLB ANT Example
1. Calibrate the RET antenna named 0_0N0A0RET_3G.CLB ANT: OPMODE=NAME, NAME="0_0N0A0RET_3G";2. Calibrate the RET antenna connected to antenna connector N0A in subrack 3 of cabinet 0.CLB ANT: OPMODE=CSAT, SRN=3, ACN=N0A, DEVTP=SINGLE_RET;
SET ANTTILTExample
1. Set the tilt of the RET antenna named 0_0R0A0RET_3G to 2°.SET ANTTILT: OPMODE=NAME, NAME="0_0R0A0RET_3G", TILT=20;2. Set the tilt of the RET antenna connected to antenna connector R0A in subrack 60 of cabinet 0 to 2°.SET ANTTILT: OPMODE=CSAT, SRN=60, ACN=R0A, DEVTP=SINGLE_RET, TILT=20;
Check RCU functionality
Check Failure Cause:--Not Calibrated---------check HARDWARE--Motor Fault-------------check HARDWARE--RCU not in Position—check HARDWARE
SOFTWARE SOLUTION
Reset the affected ALD.
RST ALD Example
1. Reset the RET antenna named 0_0N0A0RET_3G.RST ALD: OPMODE=NAME, NAME="0_0R0A0RET_3G";
If alarm not cleared using SOFTWARE SOLUTION,then go to HARDWARE SOLUTION
CHECK AISG CABLE FUNCTIONALITY
USE MULTIMETER TO CHECK THE CONNECTIVITY OF EACH PINPINS 1, 3, 5, 6, 7 SHORTED = CABLE is OKIf one or more of the PINS 1, 3, 5, 6, 7OPEN = CABLE is defective
HARDWARE SOLUTIONHOW TO CHANGE AISG CABLE
1. SET ALDPWRSW to OFF2. Replace AISG cable.3. SET ALDPWRSW to ON
HARDWARE SOLUTIONHOW TO CHANGE/REMOVE RCU
1. RMV ALD and then SCN ALD to verify the ALD is removed
2. SET ALDPWRSW to OFF. 3. Remove RCU device and cable.4. Install RCU device and cable.5. SET ALDPWRSW to ON. Then, ADD ALD 6. SCN ALD to scan the new ALD device.7. DLD ALDCFG to load the configuration of RCU if new
RCU is used.
ALDCFG is located on the NodeB software.
HOW TO CHANGE SMBT/TMA
HARDWARE SOLUTION
1. BLK BRD ( N0A=SN 0, N2A=SN 2, N4A-SN 4)2. SET TXSW to OFF.3. Remove SMBT/TMA devices and cables.4. Install SMBT/TMA devices and cables.5. SET TXSW to ON.6. UBL BRD.
THANK YOU