All rights reserved © 2010, Mobiserve Prepared By: RIZWAN AHMED RAFIQ Operation Support Engineer (Training & Consultancy) ALCATEL BTS

description

Alcatel BSS

Transcript of Alcatel BSS

Page 1: Alcatel BSS

All rights reserved © 2010, Mobiserve

Prepared By: RIZWAN AHMED RAFIQ Operation Support Engineer (Training & Consultancy)

ALCATEL BTS

ALCATEL BTS

Page 2: Alcatel BSS

All rights reserved © 2010, Mobiserve

 The BTS provides two-way radio communication between the PSTN and Mobile Station (Mobile Set) located in a single GSM cell. It also provides a similar link between the mobile station and the rest of the networks. The BTS provides on interface for the digital baseband signals used by the land based networks and the GSM radio signals used by mobile station.

BTS Role in GSM Network

Page 3: Alcatel BSS

All rights reserved © 2010, Mobiserve

Logical position of BTS in BSS

Page 4: Alcatel BSS

All rights reserved © 2010, Mobiserve

Functional Architecture of BTS

Page 5: Alcatel BSS

All rights reserved © 2010, Mobiserve

As the principal interface between the PSTN and Mobile Stations, the BTS performs four primary functions.

Transmission function: which manage the transfer of traffic and control data between the BTS and BSC.

Telecommunication functions: which manage the transfer of traffic and control data between the BTS and Mobile Station.

O&M function: which supervise the operation of the BTS.

Support function: which provides a logical and physical environment in which the BTS functions can be realized.

BTS Functions

Communication between the transmission, telecommunication, and O&M functions is managed according to the OSI model. The BTS functions are concerned with layer 1 (Physical), Layer 2 (Data Link), and Layer 3 (Network) of this model.

Page 6: Alcatel BSS

All rights reserved © 2010, Mobiserve

To minimize operating costs, all data passed between the BTS and BSC in Time division multiplexed onto a single physical interface. This is the Abis Interface, which carries all the data sent between the BSC and BTS. Logical links between the BSC and BTS handles the following information:

Transmission Functions

Signaling data used for control purposes

O&M data for the BTS transmission module

O&M data for the BTS entities

User data in the form of speech and data

traffic.

Page 7: Alcatel BSS

All rights reserved © 2010, Mobiserve

For BTS and BSC multiplexing equipment is normally connected using dedicated cabling. Other method of Abis Interface connection can be used for BTS, where the installation of the dedicated cabling in not possible. In this case, control of the transmission medium is in the hands of third party.

Abis Interface:

Microwave Link (used where line of sight radio path is

available.

Leased Line (Copper Cable or Fiber Optic used where the

distance

between the BSC and BTS is too great for microwave).

Satellite Link (Used where Previous two methods are not

possible)

Transmission Functions

Page 8: Alcatel BSS

All rights reserved © 2010, Mobiserve

There are two primary telecommunication functions:

Based band functions modulate and encode traffic and signaling data from the BSC according to GSM recommendations. This data is then sent to the Mobile Stations using the RF function. Traffic and signaling received from the Mobile Stations is demodulated and decoded to recover the baseband data.

Baseband Functions:

Telecommunication Function

Page 9: Alcatel BSS

All rights reserved © 2010, Mobiserve

Telecommunication Function

RF functions enable traffic and signaling to be sent and received over the Air Interface as a radio signal. A special link layer protocol ensures the reliable transfer of signaling data over the Air Interface.For antenna Diversity, the telecommunication function uplink path is duplicated. The duplicated functions intend from the antennas, through the RF functions.

RF Function:

Page 10: Alcatel BSS

All rights reserved © 2010, Mobiserve

O&M Functions

O&M functions monitor and control the correct operation of the BTS and its external interfaces. These function are shared between the BTS and BSC. The BSC provides overall control.The O&M function use Layer 2 links for BTS internal communications. A terminal connected via an MMI is used for local operator control of the BTS.

There are three categorized of O&M function:Configuration ManagementFault ManagementExternal Alarm Handling.

The O&M function also control the operation of the RF self-tests and manage the actions required by the BTS recovery Strategy.

Page 11: Alcatel BSS

All rights reserved © 2010, Mobiserve

Support Function

The support function provides a number of services relevant to the internal working of the BTS are:

Internal Power Supplies.

Internal Temperature Control.

Master Frequency.

Clock generation and distribution.

External alarm collection.

Internal self tests.

Page 12: Alcatel BSS

All rights reserved © 2010, Mobiserve

Introduction ofALCATEL

BTS

Introduction ofALCATEL

BTS

Page 13: Alcatel BSS

All rights reserved © 2010, Mobiserve

BTS Circuit Breakers (BCB)

Network Interface Card

External Alarm Circuit Board (EACB)

Shelf # 5

Shelf # 4

Shelf # 3

Shelf # 2

Shelf # 1

Combiners

TRE

SUMA Card

Page 14: Alcatel BSS

All rights reserved © 2010, Mobiserve

Port Address:

Formula:

16n + 1 ( n = shelf number )

This formula is for the first port of each shelf. For remaining three ports add 3 in the above formula for each port.

Page 15: Alcatel BSS

All rights reserved © 2010, Mobiserve

External Alarm Circuit Board (EACB)

Abis Patching

BTS Circuit Breakers (BCB)

Clock Port

Page 16: Alcatel BSS

All rights reserved © 2010, Mobiserve

BTS Circuit Breakers

(BCB)

Page 17: Alcatel BSS

All rights reserved © 2010, Mobiserve

External Alarm Circuit Board

(EACB)

Page 18: Alcatel BSS

All rights reserved © 2010, Mobiserve

Abis Patching

Clock Port

Page 19: Alcatel BSS

All rights reserved © 2010, Mobiserve

Transmitter Connector

Antenna Connector

Lock Fastener

Module Extractor

Receiver Connector

Equipment Label

Bridge

Page 20: Alcatel BSS

All rights reserved © 2010, Mobiserve

Lock Fastener

Transmitter Connector

Module Extractor

Receiver Connector

Antenna Connector

Equipment Label

Bridge

Page 21: Alcatel BSS

All rights reserved © 2010, Mobiserve

Lock Fastener

Transmitter Connector

Module Extractor

Equipment Label

ON/OFF Switch

USB Test Connector

Receiver Connector

LEDs

Page 22: Alcatel BSS

All rights reserved © 2010, Mobiserve

Abis ½ Connector

Lock Fastener

Equipment Label

BTS ConnectionArea Connector

BTS Terminal Connector

Test Connector

USB Connector

LEDs

Page 23: Alcatel BSS

All rights reserved © 2010, Mobiserve

Remote Inventory

Cable(RI Cable)

Page 24: Alcatel BSS

All rights reserved © 2010, Mobiserve

Remote Inventory Cable

(RI Cable)

Page 25: Alcatel BSS

All rights reserved © 2010, Mobiserve

Cabinet Cooling Fan

Page 26: Alcatel BSS

All rights reserved © 2010, Mobiserve

Connect to Alcatel BTS Using

BTS-Terminal release B9

Connect to Alcatel BTS Using

BTS-Terminal release B9

Page 27: Alcatel BSS

All rights reserved © 2010, Mobiserve

User Name

(COMMTE)

Or(UPGRAD)

Password(COMMT

E)Or

(SUMSUP)

Page 28: Alcatel BSS

All rights reserved © 2010, Mobiserve

Press Baud rate button to set it

Page 29: Alcatel BSS

All rights reserved © 2010, Mobiserve

Select Baud rate = 19200

Select the appropriate COM Port

Page 30: Alcatel BSS

All rights reserved © 2010, Mobiserve

Press F2 OR “Connect/Disconnect”

button OR

File->Connect/Disconnect from menu

Page 31: Alcatel BSS

All rights reserved © 2010, Mobiserve

Following windows will open on establishing successful

connection

Menu bar will be changed on establishing successful

connection

Page 32: Alcatel BSS

All rights reserved © 2010, Mobiserve

Monitor Active Alarms

Page 33: Alcatel BSS

All rights reserved © 2010, Mobiserve

External Active Alarms Show Here

Page 34: Alcatel BSS

All rights reserved © 2010, Mobiserve

Show Hardware Configuration (Ctrl H)

Page 35: Alcatel BSS

All rights reserved © 2010, Mobiserve

Select Appropriate Module

Select OK

Select “All”

Close

Page 36: Alcatel BSS

All rights reserved © 2010, Mobiserve

SUMA Card = OMU 1

Rack A (BTS Cabinet # 1)

Shelf # 2

Slot # 7

Page 37: Alcatel BSS

All rights reserved © 2010, Mobiserve

SBL Module States (F5)

Page 38: Alcatel BSS

All rights reserved © 2010, Mobiserve

VSWR Values

Antenna 0=A

Antenna 1=B

RA 1= Combiner 1 Sector A

Page 39: Alcatel BSS

All rights reserved © 2010, Mobiserve

SBL Module States (F3)

Page 40: Alcatel BSS

All rights reserved © 2010, Mobiserve

SBL Management

Page 41: Alcatel BSS

All rights reserved © 2010, Mobiserve

SBL Management Read

Initialize

Disable

Restart

Reset

CloseSelect Module

Page 42: Alcatel BSS

All rights reserved © 2010, Mobiserve

Execution Result

Selected Module Type

State of the Module (NEQ/OPR/IT)

Page 43: Alcatel BSS

All rights reserved © 2010, Mobiserve

Modify Hardware

Configuration

Page 44: Alcatel BSS

All rights reserved © 2010, Mobiserve

Remove Module

Page 45: Alcatel BSS

All rights reserved © 2010, Mobiserve

Click “Remove”

Select Module to Remove

Page 46: Alcatel BSS

All rights reserved © 2010, Mobiserve

End Modification of HW Configuration

Page 47: Alcatel BSS

All rights reserved © 2010, Mobiserve

Following window appears(Cabling Detection in

Progress)

Page 48: Alcatel BSS

All rights reserved © 2010, Mobiserve

Click Yes

Page 49: Alcatel BSS

All rights reserved © 2010, Mobiserve

Final Window

Page 50: Alcatel BSS

All rights reserved © 2010, Mobiserve

THANK YOU