Al 25 jaar meetbaar beter geregeld · 7 March 2019 3 Company profile Founded in 1982 (CME, Twente...

33
CO-DEVELOPMENT MANUFACTURING INNOVATION & SUPPORT 2019-03 3T - Your co-development partner Al 25 jaar meetbaar beter geregeld

Transcript of Al 25 jaar meetbaar beter geregeld · 7 March 2019 3 Company profile Founded in 1982 (CME, Twente...

Page 1: Al 25 jaar meetbaar beter geregeld · 7 March 2019 3 Company profile Founded in 1982 (CME, Twente Technology Transfer) 3T since 1994 Turnover: 9.8 Meur (2018) ISO 9001:2015 and EN

CO-DEVELOPMENT MANUFACTURING INNOVATION & SUPPORT

2019-03

3T - Your co-development partner

Al 25 jaar meetbaar beter geregeld

Page 2: Al 25 jaar meetbaar beter geregeld · 7 March 2019 3 Company profile Founded in 1982 (CME, Twente Technology Transfer) 3T since 1994 Turnover: 9.8 Meur (2018) ISO 9001:2015 and EN

We continuously invest in our expertiseof electronics and embedded systems

to enable customers to supply perfect products

Our mission

7 March 20193t.nl 2

Page 3: Al 25 jaar meetbaar beter geregeld · 7 March 2019 3 Company profile Founded in 1982 (CME, Twente Technology Transfer) 3T since 1994 Turnover: 9.8 Meur (2018) ISO 9001:2015 and EN

7 March 2019 3

Company profile

◼ Founded in 1982 (CME, Twente Technology Transfer)

◼ 3T since 1994

◼ Turnover: 9.8 Meur (2018)

◼ ISO 9001:2015 and EN ISO 13485:2016 certified

◼ 75+ employees (mainly MSc/BSc)

◼ Offices in Enschede and Eindhoven

3t.nl

Page 4: Al 25 jaar meetbaar beter geregeld · 7 March 2019 3 Company profile Founded in 1982 (CME, Twente Technology Transfer) 3T since 1994 Turnover: 9.8 Meur (2018) ISO 9001:2015 and EN

Our services

7 March 2019 4

We stand for innovative products with high quality and competitive price

3t.nl

Page 5: Al 25 jaar meetbaar beter geregeld · 7 March 2019 3 Company profile Founded in 1982 (CME, Twente Technology Transfer) 3T since 1994 Turnover: 9.8 Meur (2018) ISO 9001:2015 and EN

7 March 2019 5

Co-development

◼ Customer specific solutions, from idea to phase-out

◼ In close co-operation with the customer, often under NDA

◼ Project based approach

◼ Development in-house

◼ IP owned by customer

◼ According to 3T or customer development process

◼ Strong partner network for complete product development

Development through cooperation

3t.nl

Page 6: Al 25 jaar meetbaar beter geregeld · 7 March 2019 3 Company profile Founded in 1982 (CME, Twente Technology Transfer) 3T since 1994 Turnover: 9.8 Meur (2018) ISO 9001:2015 and EN

7 March 2019 6

Manufacturing

◼ Design For Excellence (DFX) through early involvement

■ Manufacturability

■ Testability

■ Cost-effectiveness

◼ Qualified supply via our EMS partners

■ Quality Control

■ Supply Chain Management

Manufacturing integrated with development

3t.nl

Page 7: Al 25 jaar meetbaar beter geregeld · 7 March 2019 3 Company profile Founded in 1982 (CME, Twente Technology Transfer) 3T since 1994 Turnover: 9.8 Meur (2018) ISO 9001:2015 and EN

7 March 2019 7

Innovation & Support

◼ Product innovations

■ Expand functionality

■ Solve End-of-Life issues

◼ Not restricted to 3T designs

◼ Support (2nd & 3rd line)

◼ Trouble shooting / Failure analysis

Partner from idea to phase-out

3t.nl

Page 8: Al 25 jaar meetbaar beter geregeld · 7 March 2019 3 Company profile Founded in 1982 (CME, Twente Technology Transfer) 3T since 1994 Turnover: 9.8 Meur (2018) ISO 9001:2015 and EN

We have technology and quality in our DNA

Our expertise

7 March 2019 83t.nl

Page 9: Al 25 jaar meetbaar beter geregeld · 7 March 2019 3 Company profile Founded in 1982 (CME, Twente Technology Transfer) 3T since 1994 Turnover: 9.8 Meur (2018) ISO 9001:2015 and EN

7 March 2019 9

Analog electronics

◼ Signal conditioning

◼ Sensor interfaces

◼ Actuator control

◼ Data acquisition

◼ High dynamic ranges, high precision

◼ Low power, low noise, low drift

◼ EMC: low emission and high immunity

3t.nl

Page 10: Al 25 jaar meetbaar beter geregeld · 7 March 2019 3 Company profile Founded in 1982 (CME, Twente Technology Transfer) 3T since 1994 Turnover: 9.8 Meur (2018) ISO 9001:2015 and EN

7 March 2019 10

Digital electronics

◼ Microcontrollers

◼ DSPs

◼ FPGAs and SOCs

◼ PC interfaces: Gigabit Ethernet, PCIe, USB3.0

◼ Industrial interfaces: EtherCAT, Profibus, CAN(open), Modbus or DeviceNet

◼ Wireless communication: Bluetooth, Zigbee/Z-Wave, 2G/3G/4G, GPS

3t.nl

Page 11: Al 25 jaar meetbaar beter geregeld · 7 March 2019 3 Company profile Founded in 1982 (CME, Twente Technology Transfer) 3T since 1994 Turnover: 9.8 Meur (2018) ISO 9001:2015 and EN

7 March 2019 11

Power electronics

◼ Energy efficiency

◼ Heat dissipation

◼ Battery management

◼ Power management

3t.nl

Page 12: Al 25 jaar meetbaar beter geregeld · 7 March 2019 3 Company profile Founded in 1982 (CME, Twente Technology Transfer) 3T since 1994 Turnover: 9.8 Meur (2018) ISO 9001:2015 and EN

7 March 2019 12

FPGA / SoC development

◼ Intel Design Service Network Partner

◼ Xilinx Alliance Program Partner

◼ Microsemi Hardware Partner

◼ MathWorks Partner for MATLAB & Simulink

◼ Model-Based Design for VHDL/C code generation

3t.nl

Page 13: Al 25 jaar meetbaar beter geregeld · 7 March 2019 3 Company profile Founded in 1982 (CME, Twente Technology Transfer) 3T since 1994 Turnover: 9.8 Meur (2018) ISO 9001:2015 and EN

7 March 2019 13

Embedded software

◼ Drivers, Board Support Packages, Bootloaders

◼ Commercial & Open Source Operating Systems

◼ Software applications

◼ C/C++/C#/Java

◼ Protocol stack implementations (SIP, Bluetooth, KNX)

◼ Continuous Integration Environment

3t.nl

Page 14: Al 25 jaar meetbaar beter geregeld · 7 March 2019 3 Company profile Founded in 1982 (CME, Twente Technology Transfer) 3T since 1994 Turnover: 9.8 Meur (2018) ISO 9001:2015 and EN

7 March 2019 14

LabVIEW software

◼ LabVIEW FPGA

◼ LabVIEW Real-Time

◼ NI TestStand

◼ Data Acquisition

◼ Protocol Emulation

◼ Graphical Object Oriented Programming (GOOP)

◼ National Instruments Alliance Partner since 1996. LabVIEW user since 1988.

3t.nl

Page 15: Al 25 jaar meetbaar beter geregeld · 7 March 2019 3 Company profile Founded in 1982 (CME, Twente Technology Transfer) 3T since 1994 Turnover: 9.8 Meur (2018) ISO 9001:2015 and EN

7 March 2019 15

Test systems

◼ Design for Test

◼ Q-Tooling for hardware qualification

◼ P-Tooling for hardware production test

◼ Functional or pinbed tooling for testing a complete product

◼ LabVIEW & Teststand based

3t.nl

Page 16: Al 25 jaar meetbaar beter geregeld · 7 March 2019 3 Company profile Founded in 1982 (CME, Twente Technology Transfer) 3T since 1994 Turnover: 9.8 Meur (2018) ISO 9001:2015 and EN

We have technology and quality in our DNA

Our ingredients

7 March 2019 163t.nl

Page 17: Al 25 jaar meetbaar beter geregeld · 7 March 2019 3 Company profile Founded in 1982 (CME, Twente Technology Transfer) 3T since 1994 Turnover: 9.8 Meur (2018) ISO 9001:2015 and EN

7 March 2019 17

◼ Altera Arria V SOC: FPGA and dual-core ARM Cortex-A9

◼ Multiple interfaces

■ USB 3.0, GBit-Ethernet, SFP+QSFP sockets, FMC, UART, SPI, i2C, GPIO, RS-485

◼ ptxdist Linux 4.1.0

◼ PC software libraries available for C/C++, Python and LabVIEW applications

◼ Firmware support for Model-Based Design using MATLAB/Simulink

◼ FMC connector for extension boards e.g. PEPPER

◼ See: http://3t.nl/mint/

MINT: Altera Arria V SoC Multi-INTerface development board

3t.nl

Page 18: Al 25 jaar meetbaar beter geregeld · 7 March 2019 3 Company profile Founded in 1982 (CME, Twente Technology Transfer) 3T since 1994 Turnover: 9.8 Meur (2018) ISO 9001:2015 and EN

7 March 2019 18

◼ Flexible 4-channel GaN FETs based power amplifier

◼ Ideal for the control, characterization and testing of power components such as power supplies, transformers,

inductors, actuators and motors

◼ High efficiency, accuracy and bandwidth

◼ Control of output of both voltage and current

◼ 2x HALL encoder inputs

◼ FMC card compatible

◼ See: http://3t.nl/pepper/

PEPPER: Flexible Digital Precision Amplifier

3t.nl

Page 19: Al 25 jaar meetbaar beter geregeld · 7 March 2019 3 Company profile Founded in 1982 (CME, Twente Technology Transfer) 3T since 1994 Turnover: 9.8 Meur (2018) ISO 9001:2015 and EN

7 March 2019 19

Our customers

3t.nl

Page 20: Al 25 jaar meetbaar beter geregeld · 7 March 2019 3 Company profile Founded in 1982 (CME, Twente Technology Transfer) 3T since 1994 Turnover: 9.8 Meur (2018) ISO 9001:2015 and EN

7 March 2019 20

Electronic Speed Controller

◼ BLDC motor controller

◼ Sensorless control

◼ High performance, high efficiency (upto 98%)

◼ 24 Volt / 40 A / 1 kW

◼ Lost-cost, compact and scalable electronics

◼ Flexible software programmable platform

◼ IP54 protection potting

3t.nl

Page 21: Al 25 jaar meetbaar beter geregeld · 7 March 2019 3 Company profile Founded in 1982 (CME, Twente Technology Transfer) 3T since 1994 Turnover: 9.8 Meur (2018) ISO 9001:2015 and EN

7 March 2019 21

Radar tracking module

◼ High performance analog front-end for signal conditioning radar signals

◼ System on Module with Xilinx Zynq Z-7020

◼ C/C++ code for radar tracking algorithms generated via

Model-Based Design using MatLab and Simulink

◼ Digital Signal Processing in Zynq FPGA fabric

◼ eCos RTOS on one Zynq ARM core

◼ Co-development / Manufacturing

◼ See: http://3t.nl/algemeen/soc/

3t.nl

Page 22: Al 25 jaar meetbaar beter geregeld · 7 March 2019 3 Company profile Founded in 1982 (CME, Twente Technology Transfer) 3T since 1994 Turnover: 9.8 Meur (2018) ISO 9001:2015 and EN

7 March 2019 22

Forced air warming unit

◼ Raise and maintain patient temperature by means of surface warming in ORs

◼ Class IIB Medical Device (average to high risk)

■ IEC 60601-1

■ Software conform IEC 62304 Class B (non-serious injury)

■ UL/CE approval

◼ Patent pending on temperature control principle

◼ Test & Calibration test system for production

◼ Co-development

3t.nl

Page 23: Al 25 jaar meetbaar beter geregeld · 7 March 2019 3 Company profile Founded in 1982 (CME, Twente Technology Transfer) 3T since 1994 Turnover: 9.8 Meur (2018) ISO 9001:2015 and EN

7 March 2019 23

◼ Touch screen look & feel

◼ Low-cost PCB capacitive sensors

◼ Back-lighting through LEDs

◼ Design for mass volume production (>100K per year)

◼ Industrial design by

◼ Co-development

User interface using capacitive sensors

3t.nl

Page 24: Al 25 jaar meetbaar beter geregeld · 7 March 2019 3 Company profile Founded in 1982 (CME, Twente Technology Transfer) 3T since 1994 Turnover: 9.8 Meur (2018) ISO 9001:2015 and EN

7 March 2019 24

LIMA Cell Monitor

◼ Accurate coverage information on cells in mobile networks

◼ Flexible architecture using PCIe modems

◼ Supports GSM/2G, 3G and 4G networks

◼ System on Module with i.MX.6

◼ GPS, Ethernet, wifi, 14 ports USB hub

◼ Fit for mobile (car battery) and static use (230V)

◼ Co-development / Manufacturing / Innovation & Support

3t.nl

Page 25: Al 25 jaar meetbaar beter geregeld · 7 March 2019 3 Company profile Founded in 1982 (CME, Twente Technology Transfer) 3T since 1994 Turnover: 9.8 Meur (2018) ISO 9001:2015 and EN

7 March 2019 25

Smart Sensor Interface for pyranometer

◼ Digital signal processing

◼ Sensor calibration

◼ Digital interface (Modbus)

◼ Small size electronics

◼ Extreme low power

◼ Software design in UML, 17K lines C/C++ code

◼ Co-development / Manufacturing / Innovation & Support

◼ See: http://3t.nl/algemeen/ssi/

3t.nl

Page 26: Al 25 jaar meetbaar beter geregeld · 7 March 2019 3 Company profile Founded in 1982 (CME, Twente Technology Transfer) 3T since 1994 Turnover: 9.8 Meur (2018) ISO 9001:2015 and EN

7 March 2019 26

Electro Magnetic Flowmeter

◼ Electro Magnetic Flowmeter

◼ Current-loop output (4-20mA)

◼ Accuracy <1%

◼ Fit for use in nuclear power plants

◼ Free of programmable components,

Classic analog and digital design

◼ Co-development / Innovation & Support

◼ See: http://3t.nl/algemeen/analoog-meten/

3t.nl

Page 27: Al 25 jaar meetbaar beter geregeld · 7 March 2019 3 Company profile Founded in 1982 (CME, Twente Technology Transfer) 3T since 1994 Turnover: 9.8 Meur (2018) ISO 9001:2015 and EN

7 March 2019 27

Digital controller for UPS

◼ ARM Cortex M4 RISC controller / 1Gb SRAM / 1Gb Flash

for logging, controlling and interfacing

◼ 6 Ch. low power, 16/24 bit, 64ksps, Sigma-Delta ADC

◼ Xilinx Spartan6 for data acquisition of 33 analog inputs

◼ Modbus TCP/IP

◼ USB

◼ Co-development / Manufacturing / Innovation & Support

3t.nl

Page 28: Al 25 jaar meetbaar beter geregeld · 7 March 2019 3 Company profile Founded in 1982 (CME, Twente Technology Transfer) 3T since 1994 Turnover: 9.8 Meur (2018) ISO 9001:2015 and EN

7 March 2019 28

Printhead control for PCB inktjet printer

◼ Inkjet solution for PCB manufacture inner-layers

◼ Printhead control through 71 FPGA’s

◼ Implementation and qualification of real-time datapath

◼ Hardware & VHDL project

◼ Co-development / Innovation & Support

◼ See: http://3t.nl/algemeen/lunaris-datapad/

3t.nl

Page 29: Al 25 jaar meetbaar beter geregeld · 7 March 2019 3 Company profile Founded in 1982 (CME, Twente Technology Transfer) 3T since 1994 Turnover: 9.8 Meur (2018) ISO 9001:2015 and EN

7 March 2019 29

IoT: Wireless tank level monitor

◼ Internet of Things: Measuring storage tanks levels remotely

◼ PIC24 Microcontroller, Flash

◼ GPRS & GPS module

◼ Sensors for temperature, humidity & acceleration

◼ I/O configurable (analog, digital, input, output)

◼ Battery Management, Low power (Lithium cell > 3yrs)

◼ Co-development / Manufacturing / Innovation & Support

3t.nl

Page 30: Al 25 jaar meetbaar beter geregeld · 7 March 2019 3 Company profile Founded in 1982 (CME, Twente Technology Transfer) 3T since 1994 Turnover: 9.8 Meur (2018) ISO 9001:2015 and EN

7 March 2019 30

Automated verification systems

◼ Entire rack including LabVIEW Software

◼ Emulates HW environment in Testtool

◼ Early firmware testing of DUTs possible

◼ HW in loop testing

◼ Co-development / Manufacturing / Innovation & Support

◼ See: http://3t.nl/algemeen/reductie-testtijd/

3t.nl

Page 31: Al 25 jaar meetbaar beter geregeld · 7 March 2019 3 Company profile Founded in 1982 (CME, Twente Technology Transfer) 3T since 1994 Turnover: 9.8 Meur (2018) ISO 9001:2015 and EN

7 March 2019 31

Sparta ION E-bike development

◼ Direct drive control for brushless DC motor

◼ Power electronics incl. Battery- and Power Mgt System

◼ Micro-controller distributed system (3 µC)

◼ Embedded & PC software (225K lines of ASM/C/C++)

◼ Supply chain for volume production in China

◼ Co-development / Manufacturing / Innovation & Support

◼ See: http://3t.nl/algemeen/sparta-ion/

3t.nl

Page 32: Al 25 jaar meetbaar beter geregeld · 7 March 2019 3 Company profile Founded in 1982 (CME, Twente Technology Transfer) 3T since 1994 Turnover: 9.8 Meur (2018) ISO 9001:2015 and EN

7 March 2019 32

Technology Sponsor Solar Team Twente

◼ Joint development of Battery Management System

for the 2011 car

◼ 3T provides knowledge and expertise in

the field of energy storage and control

◼ Li-polymer and Li-ion-batteries

◼ See: http://3t.nl/algemeen/solar-bms/

3t.nl

Page 33: Al 25 jaar meetbaar beter geregeld · 7 March 2019 3 Company profile Founded in 1982 (CME, Twente Technology Transfer) 3T since 1994 Turnover: 9.8 Meur (2018) ISO 9001:2015 and EN

3T B.V.Institutenweg 1 Esp 4017521 PH Enschede 5633 AJ EindhovenThe Netherlands The Netherlands

T. +31 53 4 33 66 33F. +31 53 4 33 68 69

E. [email protected]. www.3t.eu