AIR TO WATER 6& j ^nL^d `& 9` nG j9M1 Õ ` M1& d^& …...RECIRCULATING TKRS RANGE ADVANTAGES...
Transcript of AIR TO WATER 6& j ^nL^d `& 9` nG j9M1 Õ ` M1& d^& …...RECIRCULATING TKRS RANGE ADVANTAGES...
RECIRCULATING TKRS RANGE ADVANTAGES
ThermoWise Energy Use Consumption.
ThermoWise Life Cycle Costing Study.
0
Jan
Gas
Gas
Electric
Electric Boiler
Heat Pump
Heat Pump
Solar
Solar
Ene
rgy
Con
sum
ptio
n pe
r da
y (In
Uni
ts)
Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec
2
4
6
8
10
12
14
16
18
Initial Cost
Running Cost over 10 Years
Running Cost over 10 Years
Running Cost over 10 Years
Running Cost over 10 Years
Running Cost over 10 Years
Initial Cost Initial Cost Initial Cost Initial Cost
0860 HEAT H20 / 0860 4328 420 TEL +27 32 947 0377 FAX +27 32 947 0349 3 JACK SMITH ROAD, BALLITO SERVICE PARK, BALLITO 4420
0860 HEAT H20 / 0860 4328 420 TEL +27 11 450 1418 FAX +27 86 602 030311
, GERMISTON 1401, JOHANNESBURG
0860 HEAT H20 / 0860 4328 420 TEL +27 FAX +27
, G
COMMERCIAL
INDUSTRIAL
AGRICULTURAL
ThermoWise RANGE Air to Water Heat Pumps
Page 1 Features & Benefits
Page 5-12 TKRS Specifications & Technical Parameters
Page 2 Quick Reference
Page 3 Commercial Units Dimensional Data
Page 4 Large Capacity Units Dimensional Data
Page 19 Commercial Installation Schematic
Page 13-18 TKRS Large Capacity Units & Technical Parameters
COMMERCIAL
INDUSTRIAL
AGRICULTURAL
ThermoWise RANGE Air to Water Heat Pumps
ermoWise AIR TO WATER HEAT PUMPSare the preferred choice within the market place!
As part of one of the world’s largest heat pump manufacturing groups, ThermoWise delivers products that are innovative, reliable and durable, and produced to the highest standards.
ThermoWise products only use environmentally friendly refrigerant gases in our heat pumps.
Tube and shell allows for minimized scale build up over a period of time, easy cleaning, high efficiency heat transfer results in increased heat transfer, enabling reliable
production, greater efficiency and faster heating times.
LCD screen, provides multiple temperature settings of the system, self diagnostic, automatic defrosting, three function timer and user friendly.
ThermoWise products support world class performance compressors, that are environmentally friendly. Extended warranties available. (T&C’s apply.)
ThermoWise products and components have been tested and proven to ensure that our products deliver durability and quality to customers. Backed by qualified technical personnel. Unmatched warranties within the industry.
Available for all technical, design and quotation queries. Call us on: 0860 HEAT H 0 2
ThermoWise RANGE Air to Water Heat Pumps
TKRS RANGE AIR TO WATER HEAT PUMP
COMMERCIAL
INDUSTRIAL
AGRICULTURAL
ThermoWise RANGE Air to Water Heat Pumps
TKRS-100E/N2-M / 200E/SN2-M / 228ES/N2-M
DATA
TKRS-300E/SN2-M / 380E/SN2-M / 450E/SN2-M
TKRS-550E/SN2-M / 630E/SN2-M
High Pressure GaugeLow Pressure GaugeWire Controller Cable Hole Sensor Cable HolePower Supply Cable Hole Water OutletWater Inlet
H
H
H
L
L
L
B
A
B
A
B
A
A
W
W
W
Model Length (mm) Wide (mm) Height (mm) A (mm) B (mm)TKRS-100E/N2-M 752 690 765 470 785TKRS-200E/SN2-M 752 690 965 470 785TKRS-228E/SN2-M 752 690 965 470 785TKRS-300E/SN2-M 1450 702 950 755 708TKRS-380E/SN2-M 1450 702 1060 755 708TKRS-450E/SN2-M 1450 702 1260 755 708TKRS-550E/SN2-M 2150 765 1290 757.5 680TKRS-630E/SN2-M 2150 765 1290 757.5 680
High Pressure Gauge (2)
Low Pressure Gauge (2)
Wire Controller Cable Hole
Sensor Cable Hole
Power Supply Cable Hole
Water Outlet
Water Inlet
Wire Controller Cable Hole
Sensor Cable Hole
Power Cable Hole
Water Outlet
Water Inlet
Low Pressure Gauge (System 1, 2, 3)
High Pressure Gauge (System 1, 2, 3)
ThermoWise RANGE Air to Water Heat Pumps
DATA
TKRS-800E/SN2-V TKRS-1000E/SN2-V TKRS-1250E/SN2-V
Base Dimensions
Base Dimensions
TKRS-1600E/SN2-V / TKRS-2000E/SN2-V / TKRS-2500E/SN2-V
H
H
L
W
W
L
Model Length (mm) Wide (mm) Height (mm) TKRS-800E/N2-V 2000 900 1880TKRS-1000E/SN2-V 2000 900 1880TKRS-1250E/SN2-V 2000 900 1880TKRS-1600E/SN2-V 2000 1700 1880TKRS-2000E/SN2-V 2000 1700 1880TKRS-2500E/SN2-V 2000 1700 1880
1200
600
1200
600
1200
600
2336
1168
3463
1732
3763
.818
81.4
0
ThermoWise RANGE Air to Water Heat Pumps
30°C Return Water Temp.
40°C Return Water Temp.
55°C Return Water Temp.
50°C Return Water Temp.
35°C Return Water Temp.
MODEL NO: TKRS - 100E/SN2-M MODEL NO: TKRS - 100E/SN2-M
INPUT 2.55kW / OUTPUT 10.5kW INPUT 2.55kW / OUTPUT 10.5kW
KW
KW
A
A
L/H
V/PH/HZ
DB{A}
KG
MM
W
RPM
M/H
ModelType / BrandNO. of compressorRated currentLocked rotor AmpThermal protectorCapacitorRefrigerant oilDisplacementCompressor Tube Connection
Model InputCapacitorSpeedDiameter of fanAir flowTypeModel Diameter of copper pipe a.Number of rowsb.Tube pitch(a)x row pitch(b)c.Fin spacingd.Fin typee.Tube outer diameterf.Coil length x width x height g.Number of circuitsModel / MakeModel / Make Model / Make Model / Make TypeModel / MakeTypeModel / MakeThe length of control cableSet Temp.Materials of water pipeWater flowWater different pressureDiameter,water inlet pipeDiameter,water outlet pipe
Dimension(L*W*H)Packing(L*W*H)NG/WG
Compressor
Fan motor
Heat Exchanger
Evaporator
Four-way Valve AC Contactor Gas-liquid SeparatorLiquid Receiver Expansion Device
Wire controller
Water system
Design pressureGas Weight(R410A) Outdoor noise level Dimensions
PCSAA
μFml
cm3mm
WμF
r/minmmm3/h
1
mm
mmmm
mmmm
m°C
m3/hKpammmmMpa
gdB(A)mmmmkg
220V/1PH/50HZ
-15°C~43°C
60°C
10,5
226
2,55
4,12
12,46
3,57
17,45
63
Power supply
Working temp
Max. outlet Water temp.
Water Heating (A20/W55)
Max. input consumption
Max. input current
Starting current
Capacity
Hot water yield
Input
cop
Rated current
Ph-V-Hz
°C
°C
KW
L/h
KW
W/W
A
KW
A
A
PA330X3CS-4MU1Rotary / Toshiba
113,163
INNER55
110032,6
16/9.52
YDK-50M-6B-31504
850/6504404000
copper tube in shell3P-A191
25x221,8
Hydrophilic aluminum 9.52 inner groove tube
1609x22x7004
Saginomiya Siemens
in compressor145VW-B04
Intelligent & LCDQ01T0017 / AOQI
1225~60copper
2,3 40
DN25DN25
4.2/0.02200055
752*690*765840*750*900
87/103
Heating Capacity Curves
COP Curves
3TF3300-0X/AC220V/
thermostatic expansion valveBAE3ZW196 / Emerson
STF-0218G /
* Minimum Recommended Circulating Pump size:1.8m³/hr excluding additional static head pressure.
INPUT 2.55kW / OUTPUT 10.5kW
MODEL NO: TKRS - 100E/SN2-M
Ambient Temp. (°C)
Ambient Temp. (°C)
ThermoWise RANGE Air to Water Heat Pumps
30°C Return Water Temp.
40°C Return Water Temp.
55°C Return Water Temp.
50°C Return Water Temp.
35°C Return Water Temp.
MODEL NO: TKRS - 200E/SN2-M
INPUT 4.55kW / OUTPUT 19kW
Heating Capacity Curves
COP Curves
40°C Return Water Temp.
35°C Return Water Temp.
MODEL NO: TKRS - 200E/SN2-M
INPUT 4.55kW / OUTPUT 19kW
MODEL NO: TKRS - 200E/SN2-M
INPUT 4.55kW / OUTPUT 19kW
KW
KW
A
A
L/H
V/PH/HZ
DB{A}
KG
MM
W
RPM
M/H
ModelType / BrandNO. of compressorRated currentLocked rotor AmpThermal protectorCapacitorRefrigerant oilDisplacementCompressor Tube Connection
Model InputCapacitorSpeedDiameter of fanAir flowTypeModel Diameter of copper pipe a.Number of rowsb.Tube pitch(a)x row pitch(b)c.Fin spacingd.Fin typee.Tube outer diameterf.Coil length x width x height g.Number of circuitsModel / MakeModel / Make Model / Make Model / Make TypeModel / MakeTypeModel / MakeThe length of control cableSet Temp.Materials of water pipeWater flowWater different pressureDiameter,water inlet pipeDiameter,water outlet pipe
Dimension(L*W*H)Packing(L*W*H)NG/WG
Compressor
Fan motor
Heat Exchanger
Evaporator
Four-way Valve AC Contactor Gas-liquid SeparatorLiquid Receiver Expansion Device
Wire controller
Water system
Design pressureGas Weight(R410A) Outdoor noise level Dimensions
PCSAA
μFml
cm3mm
WμF
r/minmmm3/h
1
mm
mmmm
mmmm
m°C
m3/hKpammmmMpa
gdB(A)mmmmkg
380V/3PH/50HZ
-15°C~43°C
60°C
19
408
4,55
4,18
7,83
6,37
10,97
52
Power supply
Working temp
Max. outlet Water temp.
Water Heating (A20/W55)
Max. input consumption
Max. input current
Starting current
Capacity
Hot water yield
Input
cop
Rated current
Ph-V-Hz
°C
°C
KW
L/h
KW
W/W
A
KW
A
A
C-SBN373H8DscrollSanyo
17,652
INNER/
170055,7
22.2/12.7
YDK-160G-632010
800/5005567000
copper tube in shell5P-A191
25x221,8
Hydrophilic aluminum 9.52 inner groove tube
1609x22x9004
Saginomiya Siemens
LF12WLG145VW-B04
Intelligent & LCDQ01T0017 / AOQI
1225~60copper
4,1 50
DN25DN25
4.2/0.023000
57752*690*965840*750*1100
119/137
3TF3300-0X/AC220V/
thermostatic expansion valveBAE6ZW195 / Emerson
STF-0408G /
* Minimum Recommended Circulating Pump size:3.27m³/hr excluding additional static head pressure.
Ambient Temp. (°C)
Ambient Temp. (°C)
ThermoWise RANGE Air to Water Heat Pumps
30°C Return Water Temp.
40°C Return Water Temp.
55°C Return Water Temp.
50°C Return Water Temp.
35°C Return Water Temp.
MODEL NO: TKRS - 228E/SN2-M
INPUT 5.16kW / OUTPUT 22.8kW
KW
KW
A
A
L/H
V/PH/HZ
DB{A}
KG
MM
W
RPM
M/H
ModelType / BrandNO. of compressorRated currentLocked rotor AmpThermal protectorCapacitorRefrigerant oilDisplacementCompressor Tube Connection
Model InputCapacitorSpeedDiameter of fanAir flowTypeModel Diameter of copper pipe a.Number of rowsb.Tube pitch(a)x row pitch(b)c.Fin spacingd.Fin typee.Tube outer diameterf.Coil length x width x height g.Number of circuitsModel / MakeModel / Make Model / Make Model / Make TypeModel / MakeTypeModel / MakeThe length of control cableSet Temp.Materials of water pipeWater flowWater different pressureDiameter,water inlet pipeDiameter,water outlet pipe
Dimension(L*W*H)Packing(L*W*H)NG/WG
Compressor
Fan motor
Heat Exchanger
Evaporator
Four-way Valve AC Contactor Gas-liquid SeparatorLiquid Receiver Expansion Device
Wire controller
Water system
Design pressureGas Weight(R410A) Outdoor noise level Dimensions
PCSAA
μFml
cm3mm
WμF
r/minmmm3/h
2
mm
mmmm
mmmm
m°C
m3/hKpammmmMpa
gdB(A)mmmmkg
380V/3PH/50HZ
-15°C~43°C
60°C
22.8
490
5.16
4.40
9
7.22
11.9
60
Power supply
Working temp
Max. outlet Water temp.
Water Heating (A20/W55)
Max. input consumption
Max. input current
Starting current
Capacity
Hot water yield
Input
cop
Rated current
Ph-V-Hz
°C
°C
KW
L/h
KW
W/W
A
KW
A
A
C-SBN453HDscroll / Sanyo
19.358
INNER/
190066.8
22.2/12.7
YDK-160G-632010
800/500556
7000copper tube in shell
5P-A191
25x221,8
Hydrophilic aluminum 9.52 inner groove tube
1609x22x9004
Saginomiya Siemens
LF12WLG145VW-B04
Intelligent & LCDQ01T0017 / AOQI
1225~60copper
4.9 50
DN25DN25
4.2/0.023000
57752*690*965840*750*1100
134/154
MODEL NO: TKRS - 228E/SN2-M
INPUT 5.16kW / OUTPUT 22.8kW
3TF3300-0X/AC220V/
thermostatic expansion valveBAE6ZW195 / Emerson
STF-0408G /
MODEL NO: TKRS - 228E/SN2-M
INPUT 5.16kW / OUTPUT 22.8kW
* Minimum Recommended Circulating Pump size:5.167m³/hr excluding additional static head pressure.
Heating Capacity Curves
COP Curves
Ambient Temp. (°C)
Ambient Temp. (°C)
ThermoWise RANGE Air to Water Heat Pumps
30°C Return Water Temp.
40°C Return Water Temp.
55°C Return Water Temp.
50°C Return Water Temp.
35°C Return Water Temp.
MODEL NO: TKRS - 300E/SN2-M
INPUT 7.2kW / OUTPUT 30kW
KW
KW
A
A
L/H
V/PH/HZ
DB{A}
KG
MM
W
RPM
M/H
ModelType / BrandNO. of compressorRated currentLocked rotor AmpThermal protectorCapacitorRefrigerant oilDisplacementCompressor Tube Connection
Model InputCapacitorSpeedDiameter of fanAir flowTypeModel Diameter of copper pipe a.Number of rowsb.Tube pitch(a)x row pitch(b)c.Fin spacingd.Fin typee.Tube outer diameterf.Coil length x width x height g.Number of circuitsModel / MakeModel / Make Model / Make Model / Make TypeModel / MakeTypeModel / MakeThe length of control cableSet Temp.Materials of water pipeWater flowWater different pressureDiameter,water inlet pipeDiameter,water outlet pipe
Dimension(L*W*H)Packing(L*W*H)NG/WG
Compressor
Fan motor
Heat Exchanger
Evaporator
Four-way Valve AC Contactor Gas-liquid SeparatorLiquid Receiver Expansion Device
Wire controller
Water system
Design pressureGas Weight(R410A) Outdoor noise level Dimensions
PCSAA
μFml
cm3mm
WμF
r/minmmm3/h
2
mm
mmmm
mmmm
m°C
m3/hKpammmmMpa
gdB(A)mmmmkg
380V/3PH/50HZ
-15°C~43°C
60°C
30
645
7,2
4,17
12
10,08
18,36
57
Power supply
Working temp
Max. outlet Water temp.
Water Heating (A20/W55)
Max. input consumption
Max. input current
Starting current
Capacity
Hot water yield
Input
cop
Rated current
Ph-V-Hz
°C
°C
KW
L/h
KW
W/W
A
KW
A
A
C-SBN303H8Dscroll / Sanyo
25,845
INNER/
150039,9
22.2/12.7
YDK-160G-632010
800/500556
7000copper tube in shell
4P-A192
25x221,8
Hydrophilic aluminum 9.52 inner groove tube
two1082x44x90010
Saginomiya Siemens
LF12WLG145VW-B04
Intelligent & LCDQ01T0017 / AOQI
1225~60copper
6,4 55
DN40DN40
4.2/0.023100*2
581450*702*950
1525*805*1110236/279
MODEL NO: TKRS - 300E/SN2-M
INPUT 7.2kW / OUTPUT 30kW
3TF3300-0X/AC220V/
thermostatic expansion valveBAE4.5ZW195 / Emerson
STF-0408G /
MODEL NO: TKRS - 300E/SN2-M
INPUT 7.2kW / OUTPUT 30kW
* Minimum Recommended Circulating Pump size:5.167m³/hr excluding additional static head pressure.
Heating Capacity Curves
COP Curves
Ambient Temp. (°C)
Ambient Temp. (°C)
ThermoWise RANGE Air to Water Heat Pumps
30°C Return Water Temp.
40°C Return Water Temp.
55°C Return Water Temp.
50°C Return Water Temp.
35°C Return Water Temp.
INPUT 9.2kW / OUTPUT 38kW
MODEL NO: TKRS - 380E/SN2-M
MODEL NO: TKRS - 380E/SN2-M
INPUT 9.2kW / OUTPUT 38kW
Heating Capacity Curves
COP Curves
MODEL NO: TKRS - 380E/SN2-M
INPUT 9.2kW / OUTPUT 38kW
KW
KW
A
A
L/H
V/PH/HZ
DB{A}
KG
MM
W
RPM
M/H
ModelType / BrandNO. of compressorRated currentLocked rotor AmpThermal protectorCapacitorRefrigerant oilDisplacementCompressor Tube Connection
Model InputCapacitorSpeedDiameter of fanAir flowTypeModel Diameter of copper pipe a.Number of rowsb.Tube pitch(a)x row pitch(b)c.Fin spacingd.Fin typee.Tube outer diameterf.Coil length x width x height g.Number of circuitsModel / MakeModel / Make Model / Make Model / Make TypeModel / MakeTypeModel / MakeThe length of control cableSet Temp.Materials of water pipeWater flowWater different pressureDiameter,water inlet pipeDiameter,water outlet pipe
Dimension(L*W*H)Packing(L*W*H)NG/WG
Compressor
Fan motor
Heat Exchanger
Evaporator
Four-way Valve AC Contactor Gas-liquid SeparatorLiquid Receiver Expansion Device
Wire controller
Water system
Design pressureGas Weight(R410A) Outdoor noise level Dimensions
PCSAA
μFml
cm3mm
WμF
r/minmmm3/h
2
mm
mmmm
mmmm
m°C
m3/hKpammmmMpa
gdB(A)mmmmkg
380V/3PH/50HZ
-15°C~43°C
60°C
38
817
9,2
4,13
15,84
12,88
22,18
68
Power supply
Working temp
Max. outlet Water temp.
Water Heating (A20/W55)
Max. input consumption
Max. input current
Starting current
Capacity
Hot water yield
Input
cop
Rated current
Ph-V-Hz
°C
°C
KW
L/h
KW
W/W
A
KW
A
A
C-SBN373H8Dscroll / Sanyo
27,652
INNER/
170055,7
22.2/12.7
YDK-160G-632010
800/5005567000
copper tube in shell5P-A192
25x221,8
Hydrophilic aluminum 9.52 inner groove tube
two 1082x44x100012
Saginomiya Siemens
LF12WLG145VW-B04
Intelligent & LCDQ01T0017 / AOQI
1225~60copper
8,2 55
DN40DN40
4.2/0.023000*2
601450*702*10601525*805*1220
249/294
3TF3300-0X/AC220V/
thermostatic expansion valveBAE6ZW195 / Emerson
STF-0408G /
* Minimum Recommended Circulating Pump size:6.545m³/hr excluding additional static head pressure.
Ambient Temp. (°C)
Ambient Temp. (°C)
ThermoWise RANGE Air to Water Heat Pumps
30°C Return Water Temp.
40°C Return Water Temp.
55°C Return Water Temp.
50°C Return Water Temp.
35°C Return Water Temp.
MODEL NO: TKRS - 450E/SN2-M
INPUT 10.8kW / OUTPUT 45kW INPUT 10.8kW / OUTPUT 45kW
KW
KW
A
A
L/H
V/PH/HZ
DB{A}
KG
MM
W
RPM
M/H
ModelType / BrandNO. of compressorRated currentLocked rotor AmpThermal protectorCapacitorRefrigerant oilDisplacementCompressor Tube Connection
Model InputCapacitorSpeedDiameter of fanAir flowTypeModel Diameter of copper pipe a.Number of rowsb.Tube pitch(a)x row pitch(b)c.Fin spacingd.Fin typee.Tube outer diameterf.Coil length x width x height g.Number of circuitsModel / MakeModel / Make Model / Make Model / Make TypeModel / MakeTypeModel / MakeThe length of control cableSet Temp.Materials of water pipeWater flowWater different pressureDiameter,water inlet pipeDiameter,water outlet pipe
Dimension(L*W*H)Packing(L*W*H)NG/WG
Compressor
Fan motor
Heat Exchanger
Evaporator
Four-way Valve AC Contactor Gas-liquid SeparatorLiquid Receiver Expansion Device
Wire controller
Water system
Design pressureGas Weight(R410A) Outdoor noise level Dimensions
PCSAA
μFml
cm3mm
WμF
r/minmmm3/h
2
mm
mmmm
mmmm
m°C
m3/hKpammmmMpa
gdB(A)mmmmkg
380V/3PH/50HZ
-15°C~43°C
60°C
45
967
10,8
4,17
18,6
16,2
27,89
77
Power supply
Working temp
Max. outlet Water temp.
Water Heating (A20/W55)
Max. input consumption
Max. input current
Starting current
Capacity
Hot water yield
Input
cop
Rated current
Ph-V-Hz
°C
°C
KW
L/h
KW
W/W
A
KW
A
A
C-SBN453HDscroll / Sanyo
29,358
INNER/
190066,8
22.2/12.7
YDK-160G-632010
800/5005567000
copper tube in shell6P-A192
25x221,8
Hydrophilic aluminum 9.52 inner groove tube
two 1082x44x120014
Saginomiya Siemens
LF12WLG 145VW-B04
Intelligent & LCDQ01T0017 / AOQI
1225~60copper
9,7 55
DN40DN40
4.2/0.023300*2
611450*702*12601525*805*1420
268/316
MODEL NO: TKRS - 450E/SN2-M
3TF3300-0X/AC220V/
thermostatic expansion valveBAE6ZW195 / Emerson
STF-0408G /
MODEL NO: TKRS - 450E/SN2-M
INPUT 10.8kW / OUTPUT 45kW
* Minimum Recommended Circulating Pump size:7.854m³/hr excluding additional static head pressure.
Heating Capacity Curves
COP Curves
Ambient Temp. (°C)
Ambient Temp. (°C)
ThermoWise RANGE Air to Water Heat Pumps
70000
75000
65000
60000
55000
50000
45000
40000
-10 -5 0 5 10 15 20 25 30 35 40
30°C Return Water Temp.
40°C Return Water Temp.
55°C Return Water Temp.
50°C Return Water Temp.
35°C Return Water Temp.
INPUT 13.5kW / OUTPUT 55kW
MODEL NO: TKRS - 550E/SN2-M
MODEL NO: TKRS - 550E/SN2-M
INPUT 13.5kW / OUTPUT 55kW
Heating Capacity Curves
COP Curves
MODEL NO: TKRS - 550E/SN2-M
INPUT 13.5kW / OUTPUT 55kW
KW
KW
A
A
L/H
V/PH/HZ
DB{A}
KG
MM
W
RPM
M/H
ModelType / BrandNO. of compressorRated currentLocked rotor AmpThermal protectorCapacitorRefrigerant oilDisplacementCompressor Tube Connection
Model InputCapacitorSpeedDiameter of fanAir flowTypeModel Diameter of copper pipe a.Number of rowsb.Tube pitch(a)x row pitch(b)c.Fin spacingd.Fin typee.Tube outer diameterf.Coil length x width x height g.Number of circuitsModel / MakeModel / Make Model / Make Model / Make TypeModel / MakeTypeModel / MakeThe length of control cableSet Temp.Materials of water pipeWater flowWater different pressureDiameter,water inlet pipeDiameter,water outlet pipe
Dimension(L*W*H)Packing(L*W*H)NG/WG
Compressor
Fan motor
Heat Exchanger
Evaporator
Four-way Valve AC Contactor Gas-liquid SeparatorLiquid Receiver Expansion Device
Wire controller
Water system
Design pressureGas Weight(R410A) Outdoor noise level Dimensions
PCSAA
μFml
cm3mm
WμF
r/minmmm3/h
2
mm
mmmm
mmmm
m°C
m3/hKpammmmMpa
gdB(A)mmmmkg
380V/3PH/50HZ
-15°C~43°C
60°C
55
1182
13.5
4.07
23.4
20.25
33
99
Power supply
Working temp
Max. outlet Water temp.
Water Heating (A20/W55)
Max. input consumption
Max. input current
Starting current
Capacity
Hot water yield
Input
cop
Rated current
Ph-V-Hz
°C
°C
KW
L/h
KW
W/W
A
KW
A
A
C-SBN373H8Dscroll / Sanyo
37,652
INNER/
170055,7
22.2/12.7
YDK-160G-632010
800/5005567000
copper tube in shell5P-A192
25x221,8
Hydrophilic aluminum 9.52 inner groove tube
three 935*44*120021
Saginomiya Siemens
LF12WLG145VW-B04
Intelligent & LCDQ01T0017 / AOQI
1225~60copper
11.8 55
DN50DN50
4.2/0.023100*3
632150*765*12902250*865*1450
398/460
3TF3300-0X/AC220V/
thermostatic expansion valveBAE6ZW195 / Emerson
STF-0408G /
* Minimum Recommended Circulating Pump size:7.45m³/hr excluding additional static head pressure.
Ambient Temp. (°C)
Ambient Temp. (°C)
ThermoWise RANGE Air to Water Heat Pumps
80000
90000
70000
60000
50000
40000
30000
20000-10 -5 0 5 10 15 20 25 30 35 40
30°C Return Water Temp.
40°C Return Water Temp.
55°C Return Water Temp.
50°C Return Water Temp.
35°C Return Water Temp.
INPUT 16kW / OUTPUT 63kW
MODEL NO: TKRS - 630E/SN2-M
MODEL NO: TKRS - 630E/SN2-M
INPUT 16kW / OUTPUT 63kW
Heating Capacity Curves
COP Curves
MODEL NO: TKRS - 630E/SN2-M
INPUT 16kW / OUTPUT 63kW
KW
KW
A
A
L/H
V/PH/HZ
DB{A}
KG
MM
W
RPM
M/H
ModelType / BrandNO. of compressorRated currentLocked rotor AmpThermal protectorCapacitorRefrigerant oilDisplacementCompressor Tube Connection
Model / MakeInputCapacitorSpeedDiameter of fanAir flowTypeModel Diameter of copper pipe a.Number of rowsb.Tube pitch(a)x row pitch(b)c.Fin spacingd.Fin typee.Tube outer diameterf.Coil length x width x height g.Number of circuitsModel / MakeModel / Make Model / Make Model / Make TypeModel / MakeTypeModel / MakeThe length of control cableSet Temp.Materials of water pipeWater flowWater different pressureDiameter,water inlet pipeDiameter,water outlet pipe
Dimension(L*W*H)Packing(L*W*H)NG/WG
Compressor
Fan motor
Heat Exchanger
Evaporator
Four-way Valve AC Contactor Gas-liquid SeparatorLiquid Receiver Expansion Device
Wire controller
Water system
Design pressureGas Weight(R410A) Outdoor noise level Dimensions
PCSAA
μFml
cm3mm
WμF
r/minmmm3/h
3
mm
mmmm
mmmm
m°C
m3/hKpammmmMpa
gdB(A)mmmmkg
380V/3PH/50HZ
-15°C~43°C
60°C
63
1354
16
3,94
27,5
24
42
113
Power supply
Working temp
Max. outlet Water temp.
Water Heating (A20/W55)
Max. input consumption
Max. input current
Starting current
Capacity
Hot water yield
Input
cop
Rated current
Ph-V-Hz
°C
°C
KW
L/h
KW
W/W
A
KW
A
A
C-SBN453HDscroll / Sanyo
39,358
INNER/
190066,8
22.2/12.7
YDK-160G-632010
800/5005567000
copper tube in shell6P-A192
25x221,8
Hydrophilic aluminum 9.52 inner groove tube
21 Saginomiya Siemens
LF12WLG 145VW-B04
Intelligent & LCDQ01T0017 / AOQI
1225~60copper
13,5 55
DN50DN50
4.2/0.023300*3
632150*765*12902250*865*1450
398/460
3TF3300-0X/AC220V/
thermostatic expansion valveBAE6ZW195 / Emerson
STF-0408G /
* Minimum Recommended Circulating Pump size:10.851m³/hr excluding additional static head pressure.
Ambient Temp. (°C)
Ambient Temp. (°C)
ThermoWise RANGE Air to Water Heat Pumps
30°C Return Water Temp.
40°C Return Water Temp.
55°C Return Water Temp.
50°C Return Water Temp.
35°C Return Water Temp.
MODEL NO: TKRS - 800E/SN2-V380V/3PH/50HZ
-15°C~43°C60°C80
1720 19,331,79
28,9547,68 144
Power supply Working temp Max. outlet Water temp. Water Heating (A20/W55)
Max. input consumption Max. input current Starting current
CapacityHot water yieldInputRated current
Ph-V-Hz
°C°C
KWL/hKWA
KWAA
KW
KW
A
A
L/H
V/PH/HZ
DB{A}
KG
MM
W
RPM
M/H
ModelType / Brand
NO. of compressor
Capacity
Input
Locked rotor Amp
Thermal protector
Model
Brand
Input
Speed
Diameter of fan
Air flow
Quantity
Type
a.Number of rows
b.Fin spacing
c.Fin type
d.Tube outer diameter
Model
Brand
Model
Type
Brand
Type
The length of control
cable
Set Temp.
Materials of water pipe
Water flow
Water different pressure
Diameter,water inlet pipe
Diameter,water outlet pipe
Dimension(L*W*H)
Packing(L*W*H)
NG/WG
Compressor
Fan motor
Heat Exchanger
Evaporator
Four-way valve
"Gas-liquid separator”
Expansion Valve
Wire controller
Water system
Design pressure
Gas Weight(R410A)
Outdoor noise level
Dimensions
PCS
KW
KW
A
W
r/min
mm
m3/h
mm
mm
m
°C
m3/h
Kpa
mm
mm
Mpa
g
dB(A)
mm
mm
kg
scroll / Sanyo
2
29,8
9,52
80
INNER
YWF.A4T-630S-5DIA00
DUNLI
850
1350
630
10800
2
copper tube in shell
2
2
Hydrophilic aluminum
9.59 inner-groove tube
STF-0712G
Saginomiya
LF12WL05-22
“thermostatic
expansion valve“
Danfoss
Intelligent & LCD
12
25~60
copper
17,2
60
DN50
DN50
4.2/0.02
6500*2
70
2000*900*1880
2090*985*2020
530/620
INPUT 19.3kW / OUTPUT 80kW
* Minimum Recommended Circulating Pump size:13.779m³/hr excluding additional static head pressure.
INPUT 19.3kW / OUTPUT 80kW
MODEL NO: TKRS - 800E/SN2-V
MODEL NO: TKRS - 800E/SN2-V
INPUT 19.3kW / OUTPUT 80kW
Heating Capacity Curves
COP Curves
Ambient Temp. (°C)
Ambient Temp. (°C)
ThermoWise RANGE Air to Water Heat Pumps
30°C Return Water Temp.
40°C Return Water Temp.
55°C Return Water Temp.
50°C Return Water Temp.
35°C Return Water Temp.
INPUT 24kW / OUTPUT 100kW
MODEL NO: TKRS - 1000E/SN2-V
MODEL NO: TKRS - 1000E/SN2-V
INPUT 24kW / OUTPUT 100kW
Heating Capacity Curves
COP Curves
Power supply Working temp Max. outlet Water temp. Water Heating (A20/W55)
Max. input consumption Max. input current Starting current
CapacityHot water yieldInputRated current
Ph-V-Hz
°C°C
KWL/hKWA
KWAA
MODEL NO: TKRS - 1000E/SN2-V380V/3PH/50HZ
-15°C~43°C60°C1002150 24
39,53
3659,29 179
KW
KW
A
A
L/H
V/PH/HZ
DB{A}
KG
MM
W
RPM
M/H
ModelType / Brand
NO. of compressor
Capacity
Input
Locked rotor Amp
Thermal protector
Model
Brand
Input
Speed
Diameter of fan
Air flow
Quantity
Type
a.Number of rows
b.Fin spacing
c.Fin type
d.Tube outer diameter
Model
Brand
Model
Type
Brand
Type
The length of control
cable
Set Temp.
Materials of water pipe
Water flow
Water different pressure
Diameter,water inlet pipe
Diameter,water outlet pipe
Dimension(L*W*H)
Packing(L*W*H)
NG/WG
Compressor
Fan motor
Heat Exchanger
Evaporator
Four-way valve
“Gas-liquid separator”
Expansion Valve
Wire controller
Water system
Design pressure
Gas Weight(R410A)
Outdoor noise level
Dimensions
PCS
KW
KW
A
W
r/min
mm
m3/h
mm
mm
m
°C
m3/h
Kpa
mm
mm
Mpa
g
dB(A)
mm
mm
kg
C-SCP435H38A
scroll / Sanyo
2
37,2
11,8
100
INNER
YWF.A4T-630S-5DIA00
DUNLI
850
1350
630
10800
2
copper tube in shell
3
2
Hydrophilic aluminum
9.59 inner-groove tube
STF-0712G
Saginomiya
LF12WL05-22
“thermostatic
expansion valve“
Danfoss
Intelligent & LCD
12
25~60
copper
21,5
60
DN50
DN50
4.2/0.02
7800*2
70
2000*900*1880
2090*985*2020
600/690
INPUT 24kW / OUTPUT 100kW
* Minimum Recommended Circulating Pump size:17.224m³/hr excluding additional static head pressure.
Ambient Temp. (°C)
Ambient Temp. (°C)
ThermoWise RANGE Air to Water Heat Pumps
30°C Return Water Temp.
40°C Return Water Temp.
55°C Return Water Temp.
50°C Return Water Temp.
35°C Return Water Temp.
Ambient Temp. (°C)
Ambient Temp. (°C)
MODEL NO: TKRS - 1250E/SN2-VPower supply Working temp Max. outlet Water temp. Water Heating (A20/W55)
Max. input consumption Max. input current Starting current
CapacityHot water yieldInputRated current
Ph-V-Hz
°C°C
KWL/hKWA
KWAA
KW
KW
A
A
L/H
V/PH/HZ
DB{A}
KG
MM
W
RPM
M/H
ModelType / Brand
NO. of compressor
Capacity
Input
Locked rotor Amp
Thermal protector
Model
Brand
Input
Speed
Diameter of fan
Air flow
Quantity
Type
a.Number of rows
b.Fin spacing
c.Fin type
d.Tube outer diameter
Model
Brand
Model
Type
Brand
Type
The length of control
cable
Set Temp.
Materials of water pipe
Water flow
Water different pressure
Diameter,water inlet pipe
Diameter,water outlet pipe
Dimension(L*W*H)
Packing(L*W*H)
NG/WG
Compressor
Fan motor
Heat Exchanger
Evaporator
Four-way valve
“Gas-liquid separator”
Expansion Valve
Wire controller
Water system
Design pressure
Gas Weight (R410A)
Outdoor noise level
Dimensions
PCS
KW
KW
A
W
r/min
mm
m3/h
mm
mm
m
°C
m3/h
Kpa
mm
mm
Mpa
g
dB(A)
mm
mm
kg
INPUT 30.3kW / OUTPUT 125kW
380V/3PH/50HZ-15°C~43°C
60°C1252687 30,349,90
45,4574,85 210
C-SCP510H38Ascroll / Sanyo
243,913,8110
INNER
YWF.A4T-630S-5DIA00DUNLI
8501350630
108002
copper tube in shell
32
Hydrophilic aluminum
9.59 inner-groove tube
STF-0712G Saginomiya LF12WL05-22
“thermostatic
expansion valve“
DanfossIntelligent & LCD
12
25~60copper
26,9 60
DN50DN50
4.2/0.028800*2
702000*900*18802090*985*2020
620/710
* Minimum Recommended Circulating Pump size:21.531m³/hr excluding additional static head pressure.
INPUT 30.3kW / OUTPUT 125kW
MODEL NO: TKRS - 1250E/SN2-V
MODEL NO: TKRS - 1250E/SN2-V
INPUT 30.3kW / OUTPUT 125kW
Heating Capacity Curves
COP Curves
ThermoWise RANGE Air to Water Heat Pumps
30°C Return Water Temp.
40°C Return Water Temp.
55°C Return Water Temp.
50°C Return Water Temp.
35°C Return Water Temp.
INPUT 38.6kW / OUTPUT 160kW
MODEL NO: TKRS - 1600E/SN2-V
MODEL NO: TKRS - 1600E/SN2-V
INPUT 38.6kW / OUTPUT 160kW
Heating Capacity Curves
COP Curves
Power supply Working temp Max. outlet Water temp. Water Heating (A20/W55)
Max. input consumption Max. input current Starting current
CapacityHot water yieldInputRated current
Ph-V-Hz
°C°C
KWL/hKWA
KWAA
MODEL NO: TKRS - 1600E/SN2-V
KW
KW
A
A
L/H
V/PH/HZ
DB{A}
KG
MM
W
RPM
M/H
ModelType / Brand
NO. of compressor
Capacity
Input
Locked rotor Amp
Thermal protector
Model
Brand
Input
Speed
Diameter of fan
Air flow
Quantity
Type
a.Number of rows
b.Fin spacing
c.Fin type
d.Tube outer diameter
Model
Brand
Model
Type
Brand
Type
The length of control
cable
Set Temp.
Materials of water pipe
Water flow
Water different pressure
Diameter,water inlet pipe
Diameter,water outlet pipe
Dimension(L*W*H)
Packing(L*W*H)
NG/WG
Compressor
Fan motor
Heat Exchanger
Evaporator
Four-way valve
“Gas-liquid separator”
Expansion Valve
Wire controller
Water system
Design pressure
Gas Weight (R410A)
Outdoor noise level
Dimensions
PCS
KW
KW
A
W
r/min
mm
m3/h
mm
mm
m
°C
m3/h
Kpa
mm
mm
Mpa
g
dB(A)
mm
mm
kg
INPUT 38.6kW / OUTPUT 160kW
C-SCP360H38A
scroll / Sanyo
4
29,8
9,52
80
INNER
YWF.A4T-630S-5DIA00
DUNLI
850
1350
630
10800
4
copper tube in shell
3
2
Hydrophilic aluminum
9.59 inner-groove tube
STF-0712G
Saginomiya
LF12WL05-22
“thermostatic
expansion valve“
Danfoss
Intelligent & LCD
12
25~60
copper
34,4
70
DN65
DN65
4.2/0.02
6500*4
72
2000*1700*1880
2090*1780*2020
1060/1240
380V/3PH/50HZ-15°C~43°C
60°C1603439 38,6
63,57
57,995,36 334
* Minimum Recommended Circulating Pump size:27.559m³/hr excluding additional static head pressure.
Ambient Temp. (°C)
Ambient Temp. (°C)
ThermoWise RANGE Air to Water Heat Pumps
30°C Return Water Temp.
40°C Return Water Temp.
55°C Return Water Temp.
50°C Return Water Temp.
35°C Return Water Temp.
MODEL NO: TKRS - 2000E/SN2-VPower supply Working temp Max. outlet Water temp. Water Heating (A20/W55)
Max. input consumption Max. input current Starting current
CapacityHot water yieldInputRated current
Ph-V-Hz
°C°C
KWL/hKWA
KWAA
KW
KW
A
A
L/H
V/PH/HZ
DB{A}
KG
MM
W
RPM
M/H
ModelType / Brand
NO. of compressor
Capacity
Input
Locked rotor Amp
Thermal protector
Model
Brand
Input
Speed
Diameter of fan
Air flow
Quantity
Type
a.Number of rows
b.Fin spacing
c.Fin type
d.Tube outer diameter
Model
Brand
Model
Type
Brand
Type
The length of control
cable
Set Temp.
Materials of water pipe
Water flow
Water different pressure
Diameter,water inlet pipe
Diameter,water outlet pipe
Dimension(L*W*H)
Packing(L*W*H)
NG/WG
Compressor
Fan motor
Heat Exchanger
Evaporator
Four-way valve
“Gas-liquid separator”
Expansion Valve
Wire controller
Water system
Design pressure
Gas Weight (R410A)
Outdoor noise level
Dimensions
PCS
KW
KW
A
W
r/min
mm
m3/h
mm
mm
m
°C
m3/h
Kpa
mm
mm
Mpa
g
dB(A)
mm
mm
kg
INPUT 48kW / OUTPUT 200kW
C-SCP435H38Ascroll / Sanyo
437,211,8100
INNER
YWF.A4T-630S-5DIA00DUNLI
8501350630
108004
copper tube in shell
32
Hydrophilic aluminum
9.59 inner-groove tube
STF-0712G Saginomiya LF12WL05-22
“thermostatic expansion
valve“
DanfossIntelligent & LCD
12
25~60copper
43,0 70
DN65DN65
4.2/0.027800*4
722000*1700*18802090*1780*2020
1200/1380
380V/3PH/50HZ-15°C~43°C
60°C200
4299 48
79,05
72118,58
416
* Minimum Recommended Circulating Pump size:34.449m³/hr excluding additional static head pressure.
INPUT 48kW / OUTPUT 200kW
MODEL NO: TKRS - 2000E/SN2-V
MODEL NO: TKRS - 2000E/SN2-V
INPUT 48kW / OUTPUT 200kW
Heating Capacity Curves
COP Curves
Ambient Temp. (°C)
Ambient Temp. (°C)
ThermoWise RANGE Air to Water Heat Pumps
30°C Return Water Temp.
40°C Return Water Temp.
55°C Return Water Temp.
50°C Return Water Temp.
35°C Return Water Temp.
INPUT 60.6kW / OUTPUT 250kW
MODEL NO: TKRS - 2500E/SN2-V
MODEL NO: TKRS - 2500E/SN2-V
INPUT 60.6kW / OUTPUT 250kW
Heating Capacity Curves
COP Curves
Power supply Working temp Max. outlet Water temp. Water Heating (A20/W55)
Max. input consumption Max. input current Starting current
CapacityHot water yieldInputRated current
Ph-V-Hz
°C°C
KWL/hKWA
KWAA
MODEL NO: TKRS - 2500E/SN2-V
KW
KW
A
A
L/H
V/PH/HZ
DB{A}
KG
MM
W
RPM
M/H
ModelType / Brand
NO. of compressor
Capacity
Input
Locked rotor Amp
Thermal protector
Model
Brand
Input
Speed
Diameter of fan
Air flow
Quantity
Type
a.Number of rows
b.Fin spacing
c.Fin type
d.Tube outer diameter
And type
Model
Brand
Model
Type
Brand
Type
The length of control
cable
Set Temp.
Materials of water pipe
Water flow
Water different pressure
Diameter,water inlet pipe
Diameter,water outlet pipe
Dimension(L*W*H)
Packing(L*W*H)
NG/WG
Compressor
Fan motor
Heat Exchanger
Evaporator
Four-way valve
“Gas-liquid separator”
Expansion Valve
Wire controller
Water system
Design pressure
Gas Weight (R410A)
Outdoor noise level
Dimensions
PCS
KW
KW
A
W
r/min
mm
m3/h
mm
mm
m
°C
m3/h
Kpa
mm
mm
Mpa
g
dB(A)
mm
mm
kg
INPUT 60.6kW / OUTPUT 250kW
C-SCP510H38A
scroll / Sanyo
4
43,9
13,8
110
INNER
YWF.A4T-630S-5DIA00
DUNLI
850
1350
630
10800
4
copper tube in shell
3
2
Hydrophilic aluminum
9.59 inner-groove tube
STF-0712G
Saginomiya
LF12WL05-22
“thermostatic expansion
valve“
Danfoss
Intelligent & LCD
12
25~60
copper
53,7
70
DN65
DN65
4.2/0.02
8800*4
72
2000*1700*1880
2090*1780*2020
1240/1420
380V/3PH/50HZ-15°C~43°C
60°C250
5374 60,699,80
90,9149,70
509
* Minimum Recommended Circulating Pump size:43.062m³/hr excluding additional static head pressure.
Ambient Temp. (°C)
Ambient Temp. (°C)
ThermoWise RANGE Air to Water Heat Pumps
We can create a more sustainable, cleaner and safer world by making wiser energy choices.
-Robert Alan