Air Curtains7prfhz0j

download Air Curtains7prfhz0j

of 25

Transcript of Air Curtains7prfhz0j

  • 8/16/2019 Air Curtains7prfhz0j

    1/25

    403

    www.klimaoprema.hr

    GRAND, SONATA

    AIR CURTAINS

    8/S2v 2.5 (en)

  • 8/16/2019 Air Curtains7prfhz0j

    2/25

    AIR CURTAINS GRAND / SONATA

    404Design changes reserved

    The basic purpose of air curtains is to prevent air from undesiredexchange (draught) through an open door connecting two roomswith different climatic parameters. In most cases, they are installed

    at the main entrance of a building but sometimes they need to beapplied indoors between two rooms with different purposes, i.e. temperatures. Such an invisible barrier is realized by directing theair flow of an appropriate velocity into the visible plate below theopening. The barrier protects interiors from ingression of outdoor cold or wam air, dust, insects, unpleasant smell and other pollut-ants (Fig. 1.1). Moreover, additional heating of the air flow (electricor hot water heaters) is able to satisfy most thermal needs of therooms protected by air curtains whereas an installed filter ensurescontinuous indoor air purification. Air curtains are mostly installedabove the entrance by means of visible or suspended ceiling instal-lation and are characterized by simple mounting and maintenanceduring exploitation. The application of air curtains is multiple and their usefulness is evident in the following effects:

    • Controlling energy expenses as result of heating/   cooling• Preventing air from dust, insect and smoke ingression  through an open door • Stabilizing microclimatic conditions by blocking cold or   warm air penetration

    Another important effect of air curtains is cancelling temperaturedelayering, e.g. during the heating season warm air raises to higherzones of a room due to lift whereas cold air stays in lower zonesof the room.

    It brings to subjective feeling of cold, especially on legs while theair above the movement zone remains hot. On such occasion notmuch will be achieved if the effect of heating is increased.Since air curtains are installed at heights above the movement zone, they intake warm air and direct it at high velocities to lower zonesmaking a macro-whirlpool in the entire room (Fig. 1.2). Equalizing the temperatures of higher and lower zones neutralizes the feeling

    of cold and, simultaneously, need for additional heating. Finallyair curtains are economical due to their low energy consumption.

    Application

    Figure 1.2 - Protecting a room from cold outdoor air penetrationand cancelling temperature delaying

    Heated air

    Cooled air

    Clean airInsects

    Smells

    Smoke

    Dust

    Exhaust gases

    Summer heat

    Winter cool

    PRESERVES REFLECTS

    Figure 1.1

  • 8/16/2019 Air Curtains7prfhz0j

    3/25

    AIR CURTAINS GRAND / SONATA

    405Design changes reserved

    Klimaoprema Quant Line air curtains are designed for simple instal-lation, handling and maintenance while high quality components therefor guarantee functionality, reliability and longevity. The main

    characteristics of air curtains Quant Line are the following:

      • All models available lengths between 1 and 1,7 m.  • Opening heights range from 2 to 5 metara.  • Models without heater (N), with an electric (E) or with

    a hot water (W) heater are all available (models with an  electric heater are supplied without an air filter).  • Control panels are equipped with a three speed fan  controller and a double electric heating mode.  • Available air flow regulation through special outflow  blades.  • Possible harmonization with a door opening level.  • Various suspension elements as well as other   installation and connecting elements make mounting

      simple and quick.

    The basic components and corresponding charactheristics:Air curtain casings are made of sheet steel, powder coated in basicRAL 9010 colour (white). Simple mounting provides a quick andeasy approach and demounting of all the components.

    Description and Marking

    Air curtain casings are labeled with the protection class IP 20. Fansare constructed radially and contain an installed electric motoractuator. The wings are angled and do not produce much noise.

    Ventilators are labelled with the protection class IP 42 and are sup-plied with single-phase actuators containing self-greasing bearingswhich enable quiet and long-term work without maintenance.Electric heaters are made of highly alloyed steel with brass bladesin order to increase the total area. They are distributed evenly through an outlet area, which enables high quality transmission ofheat and the maximum shelflife. The power of electric heaters isselected according to the flow keeping the supply air temperatureoptimal. The protective border thermostat switches air curtains offif the casing temperature exceeds 95°C. Hot water heaters consistof copper pipes with aluminium blades. The mechanical expansionof the copper pipes ensures maximum heat transmission from theheating medium to the supply air. Heaters are in fact heat exchang-ers designed for water as a heating medium up to 100°C. Heaters

    have been tested at 25 bar. Filters (EU2) are made of solid poly-urethane foam and can be easily demounted for control examina- tion by frontal mask opening and wired holder removal. Regardingcleaning, filters are simply blown through by means of compressedair or washed with solution with mild detergent concetration. In theend, they are washed out with water jet and then dried.

    Series type  GRAND  GRAND  SONATA 

    - 25  - E  - 12- 20

    Installation height  25 - 2,0-2,5 [m]*  35 - 3,0-3,5 [m]  45 - 4,0-4,5 [m]

    Unit width10 = 1 [m]

      20 = 2 [m]

    Heater type  N - without heater   E - electric heater**  W - water heater 

    Electric heater rated power

    Ordering key

    * Sonata series only in version 25** Rated power is listed on pages 11 and 16

    Installation type  F - free hanging  C - ceiling

     - F

  • 8/16/2019 Air Curtains7prfhz0j

    4/25

    AIR CURTAINS GRAND / SONATA

    406Design changes reserved

    Grand series

    GRAND series air curtains as a part of the Klimaoprema QuantLine program are designed for installation above the gates for people’s and vehicle traffic from 2 to 4.5 m in height. The GRAND

    series is represented by models 2510, 2517, 3510, 3517, 4510,4517 available without a heater (N), with a hot water (W) or anelectric (E) heater.

  • 8/16/2019 Air Curtains7prfhz0j

    5/25

  • 8/16/2019 Air Curtains7prfhz0j

    6/25

    AIR CURTAINS GRAND / SONATA

    408Design changes reserved

    GRAND 2510W

      Air flow rate (m³/h)

    TU / T

    Itu (°C)

    1600 1400 1100

    ti(°C) Q (kW) ti(°C) Q (kW) ti(°C) Q (kW)

    90° / 70°

    0 32,9 17,5 34,6 16,3 37,5 14,3

     ∆p (kPa) 4,3 3,8 3,0

    Ф (l/h) 773 719 632

    10 38,5 15,2 40,0 14,3 42,5 12,4

     ∆p (kPa) 3,3 2,9 2,3

    Ф (l/h) 670 623 549

    20 44,1 12,8 45,3 12,0 47,4 10,5

     ∆p (kPa) 2,4 2,1 1,7Ф (l/h) 566 528 456

    80° / 60°

    0 28,1 15,0 29,5 13,9 32,1 12,2

     ∆p (kPa) 3,3 2,8 2,2Ф (l/h) 657 612 538

    10 33,7 12,6 34,9 11,7 37,0 10,3

     ∆p (kPa) 2,4 2,1 1,6Ф (l/h) 554 516 454

    20 39,2 10,2 40,2 9,6 41,87 8,4

     ∆p (kPa) 1,6 1,4 1,1Ф (l/h) 451 420 370

    55° / 45°

    0 20,5 10,9 21,5 10,2 23,3 8,9

     ∆p (kPa) 6,9 5,9 4,7Ф (l/h) 952 885 777

    10 26,1 8,6 26,8 8,0 28,3 7,0

     ∆p (kPa) 4,3 3,8 3,0Ф (l/h) 746 694 610

    20 31,5 6,2 32,1 5,7 33,1 5,1

     ∆p (kPa) 2,3 2,1 1,6Ф (l/h) 538 501 441

    GRAND 2517W

      Air flow rate (m³/h)

    TU / T

    Itu (°C)

    2500 1900 1200

    ti(°C) Q (kW) t

    i(°C) Q (kW) t

    i(°C) Q (kW)

    90° / 70°

    0 36,8 30,8 40,9 25,9 48,5 18,6

     ∆p (kPa) 17,4 12,6 6,8

    Ф (l/h) 1361 1142 821

    10 42,1 26,9 45,6 22,6 52,22 16,2

     ∆p (kPa) 13,6 9,8 5,3

    Ф (l/h) 1187 997 717

    20 47,3 23,0 50,28 19,3 55,88 13,9 ∆p (kPa) 10,1 7,3 3,9Ф (l/h) 1013 852 613

    80° / 60°

    0 31,7 26,6 35,3 22,3 41,8 16,1

     ∆p (kPa) 13,5 9,7 5,3Ф (l/h) 1169 981 706

    10 37,0 22,6 40,0 19,0 45,56 13,7

     ∆p (kPa) 10 7,2 3,9Ф (l/h) 995 836 601

    20 42,2 18,7 44,6 15,7 49,2 11,3

     ∆p (kPa) 7,0 5,1 2,8Ф (l/h) 820 690 497

    55° / 45°

    0 22,9 19,2 25,5 16,1 30,2 11,6

     ∆p (kPa) 27,7 20,0 10,9Ф (l/h) 1677 1406 1010

    10 28,2 15,3 30,17 12,8 33,9 9,2 ∆p (kPa) 18,1 13,1 7,1Ф (l/h) 1330 1116 802

    20 33,3 11,2 34,8 9,4 37,52 6,8

     ∆p (kPa) 10,3 7,4 4,1Ф (l/h) 980 823 592

  • 8/16/2019 Air Curtains7prfhz0j

    7/25

    AIR CURTAINS GRAND / SONATA

    409Design changes reserved

    GRAND 2520W

      Air flow rate (m³/h)

    TU / T

    Itu (°C)

    3200 2800 2200

    ti(°C) Q (kW) ti(°C) Q (kW) ti(°C) Q (kW)

    90° / 70°

    0 36,6 38,4 38,9 36,5 42 30,9

     ∆p (kPa) 28 28 21

    Ф (l/h) 1730 1609 1365

    10 42,2 34,6 44 31,9 47,2 27,5

     ∆p (kPa) 26 22,4 16,9

    Ф (l/h) 1528 1412 1214

    20 47,6 29,8 49 27,4 51,7 23,6

     ∆p (kPa) 19,7 16,9 17Ф (l/h) 1318 1212 1041

    80° / 60°

    0 32 34,2 33,8 31,6 37 27,2

     ∆p (kPa) 25,9 22,3 16,9Ф (l/h) 1506 1392 1197

    10 37,2 29,2 38,8 27 41,6 23,3

     ∆p (kPa) 19,3 16,8 16,9Ф (l/h) 1285 1190 1026

    20 42,6 24,4 43,8 22,5 46,1 19,4

     ∆p (kPa) 18,5 15,8 853Ф (l/h) 1075 990 12

    55° / 45°

    0 22,9 24,5 24,2 22 26,5 19,5

     ∆p (kPa) 45,2 39,1 29,7Ф (l/h) 2138 1977 1701

    10 28,3 19,6 29,2 18 31 15,5

     ∆p (kPa) 30,1 29,7 22,5Ф (l/h) 1715 1574 1353

    20 33,5 14,6 34,2 13,4 35,6 11,6

     ∆p (kPa) 20 17,3 17,3Ф (l/h) 1273 1172 1012

    GRAND 3510W

      Air flow rate (m³/h)

    TU / T

    Itu (°C)

    2500 1600 1100

    ti(°C) Q (kW) t

    i(°C) Q (kW) t

    i(°C) Q (kW)

    90° / 70°

    0 33,5 27,7 39,8 21,1 46,2 16,0

     ∆p (kPa) 13,8 8,3 4,9

    Ф (l/h) 1223 930 704

    10 39,1 24,1 44,6 18,4 50,2 13,9

     ∆p (kPa) 10,7 6,4 3,8

    Ф (l/h) 1065 811 614

    20 44,7 20,6 49,3 15,7 54,1 11,9 ∆p (kPa) 7,9 4,8 2,8Ф (l/h) 907 692 523

    80° / 60°

    0 28,8 23,8 34,8 18,1 39,8 13,7

     ∆p (kPa) 10,6 6,3 3,8Ф (l/h) 1047 797 603

    10 34,4 20,2 39,1 15,4 43,7 11,7

     ∆p (kPa) 7,8 4,7 2,8Ф (l/h) 890 678 513

    20 40,0 16,6 43,8 12,7 47,6 9,6

     ∆p (kPa) 5,7 3,3 1,9Ф (l/h) 731 558 422

    55° / 45°

    0 20,9 17,3 24,8 13,1 28,7 9,9

     ∆p (kPa) 21,8 13,1 7,8Ф (l/h) 1507 1144 866

    10 26,5 13,7 29,6 10,4 32,7 7,9 ∆p (kPa) 14,2 8,5 5,1Ф (l/h) 1191 906 685

    20 32 10 34,3 7,6 36,6 5,8

     ∆p (kPa) 7,9 4,8 2,8Ф (l/h) 873 665 503

  • 8/16/2019 Air Curtains7prfhz0j

    8/25

    AIR CURTAINS GRAND / SONATA

    410Design changes reserved

    GRAND 3517W

      Air flow rate (m³/h)

    TU / T

    Itu (°C)

    3850 2100 1300

    ti(°C) Q (kW) ti(°C) Q (kW) ti(°C) Q (kW)

    90° / 70°

    0 36,4 47,0 45,6 31,8 52,8 22,8

     ∆p (kPa) 17,9 8,7 4,7

    Ф (l/h) 2074 1402 1008

    10 41,8 41,0 49,7 27,8 56,0 20,0

     ∆p (kPa) 13,9 6,8 3,7

    Ф (l/h) 1810 1226 881

    20 47,0 35,1 53,7 23,8 59,1 17,1

     ∆p (kPa) 10,3 5,1 2,7Ф (l/h) 1545 1048 753

    80° / 60°

    0 31,4 40,5 39,3 27,4 45,6 19,7

     ∆p (kPa) 13,8 6,7 3,7Ф (l/h) 1783 1205 866

    10 36,7 34,5 43,4 23,4 48,8 16,8 ∆p (kPa) 10,3 5,0 2,7Ф (l/h) 1517 1028 739

    20 41,9 28,5 47,4 19,3 51,8 13,9

     ∆p (kPa) 7,2 3,5 1,9Ф (l/h) 1251 849 611

    55° / 45°

    0 22,7 29,3 28,4 19,8 32,9 14,2

     ∆p (kPa) 28,5 13,7 7,4Ф (l/h) 2556 1724 1238

    10 28,0 23,2 32,4 15,7 36,0 11,3

     ∆p (kPa) 18,6 9,0 4,9Ф (l/h) 2028 1370 984

    20 33,2 17,1 36,5 11,6 39,1 8,3

     ∆p (kPa) 10,6 5,2 2,8Ф (l/h) 1494 1012 727

    GRAND 3520W

      Air flow rate (m³/h)

    TU / T

    Itu (°C)

    5000 3200 2200

    ti(°C) Q (kW) t

    i(°C) Q (kW) t

    i(°C) Q (kW)

    90° / 70°

    0 36,4 60,9 43 46 49,2 36,2

     ∆p (kPa) 29,5 20,4 17,2

    Ф (l/h) 2689 2033 1599

    10 41,6 53 47,6 40,4 53,1 31,8

     ∆p (kPa) 26,5 16 13,5

    Ф (l/h) 2343 1784 1406

    20 47,1 45,8 52,2 34,8 56,8 27,4 ∆p (kPa) 20,2 15,9 10Ф (l/h) 2023 1538 1209

    80° / 60°

    0 31,4 52,5 37,4 40 42,6 31,3

     ∆p (kPa) 26,4 16 13,3Ф (l/h) 2309 1760 1379

    10 36,8 45 42 34,4 46,4 26,9

     ∆p (kPa) 19,8 15,8 10Ф (l/h) 1978 1512 1182

    20 42,2 37,5 46,4 28,5 50,2 22,4

     ∆p (kPa) 18,6 11,2 11,2Ф (l/h) 1649 1255 987

    55° / 45°

    0 22,5 37,6 26,7 28,5 30,4 22,3

     ∆p (kPa) 46,3 32,2 20,6Ф (l/h) 3282 2492 1951

    10 27,8 29,8 31,3 22,8 34,3 17,9 ∆p (kPa) 34,9 21,4 17,7Ф (l/h) 2606 1996 1565

    20 33,3 22,4 35,8 17 37,9 13,3

     ∆p (kPa) 20,7 16,2 10,2Ф (l/h) 1960 1490 1161

  • 8/16/2019 Air Curtains7prfhz0j

    9/25

    AIR CURTAINS GRAND / SONATA

    411Design changes reserved

    GRAND 4510W

      Air flow rate (m³/h)

    TU / T

    Itu (°C)

    4000 3350 2500

    ti(°C) Q (kW) ti(°C) Q (kW) ti(°C) Q (kW)

    90° / 70°

    0 39,8 53,0 42,6 47,7 47,5 39,5

     ∆p (kPa) 6,2 4,9 3,6

    Ф (l/h) 2341 2104 1745

    10 44,6 46,0 47,0 41,5 51,2 34,5

     ∆p (kPa) 4,7 3,9 2,7

    Ф (l/h) 2034 1831 1520

    20 49,3 39,1 51,3 35,6 54,9 29,3

     ∆p (kPa) 3,5 2,9 2,0Ф (l/h) 1726 1556 1520

    80° / 60°

    0 34,1 45,5 36,6 40,9 40,7 33,9

     ∆p (kPa) 4,7 3,8 2,7Ф (l/h) 1999 1797 1491

    10 38,9 38,5 40,9 34,7 44,5 28,8

     ∆p (kPa) 3,4 2,8 2,0Ф (l/h) 1691 1523 1266

    20 43,5 31,4 45,2 28,4 48,1 23,6

     ∆p (kPa) 2,3 1,9 1,4Ф (l/h) 1382 1246 1038

    55° / 45°

    0 24,7 33,0 26,4 29,6 29,4 24,5

     ∆p (kPa) 9,7 7,9 5,5Ф (l/h) 2875 2578 2134

    10 29,4 25,9 30,8 23,3 33,1 19,3

     ∆p (kPa) 6,2 5,1 3,5Ф (l/h) 2261 2032 1684

    20 34,1 18,8 35,1 17,0 36,8 14,1

     ∆p (kPa) 3,4 2,8 1,9Ф (l/h) 1642 1479 1229

    GRAND 4517W

      Air flow rate (m³/h)

    TU / T

    Itu (°C)

    6400 5560 4350

    ti(°C) Q (kW) t

    i(°C) Q (kW) t

    i(°C) Q (kW)

    90° / 70°

    0 44,4 95,0 46,8 87,1 51,0 74,0

     ∆p (kPa) 25,0 21,8 16,0

    Ф (l/h) 4196 3841 3267

    10 48,8 83,2 50,9 76,2 54,6 64,9

     ∆p (kPa) 20,0 16,9 12,5

    Ф (l/h) 3671 3363 2863

    20 53,1 71,3 54,9 65,3 58,1 55,7 ∆p (kPa) 14,9 12,7 9,5Ф (l/h) 3145 2883 2458

    80° / 60°

    0 38,4 82,4 40,5 75,5 44,2 64,2

     ∆p (kPa) 19,9 16,9 12,5Ф (l/h) 3619 3314 2820

    10 42,8 70,4 44,6 64,5 47,8 55,0

     ∆p (kPa) 14,9 12,7 9,4Ф (l/h) 3093 2835 2415

    20 47,1 58,4 48,6 53,5 51,3 45,7

     ∆p (kPa) 10,5 8,9 6,7Ф (l/h) 2564 2356 2008

    55° / 45°

    0 27,5 59,1 29,0 54,0 31,6 45,9

     ∆p (kPa) 40,4 34,2 25,2Ф (l/h) 5147 4708 3997

    10 31,9 47,1 33,1 43,1 35,1 36,6 ∆p (kPa) 26,48 22,48 16,66Ф (l/h) 4100 3753 3191

    20 36,2 35,0 37,0 32,0 38,6 27,3

     ∆p (kPa) 15,27 13,01 9,68Ф (l/h) 3044 2790 3277

  • 8/16/2019 Air Curtains7prfhz0j

    10/25

    AIR CURTAINS GRAND / SONATA

    412Design changes reserved

    GRAND 4520W

      Air flow rate (m³/h)

    TU / T

    Itu (°C)

    8000 6700 5000

    ti(°C) Q (kW) ti(°C) Q (kW) ti(°C) Q (kW)

    90° / 70°

    0 44,2 118,3 47 105,4 52,2 87,3

     ∆p (kPa) 40,2 32,4 26

    Ф (l/h) 5224 4653 3857

    10 48,6 103,7 51,3 92,9 55,5 76,4

     ∆p (kPa) 31,4 29,2 20,3

    Ф (l/h) 4580 4103 3375

    20 53 89,3 55,2 79,7 59 65

     ∆p (kPa) 27,1 21,9 15,4Ф (l/h) 3942 3521 2912

    80° / 60°

    0 38,4 102,8 41 91,9 45,36 75,8

     ∆p (kPa) 31,4 29 20,3Ф (l/h) 4518 4040 3332

    10 42,8 88,1 45 78,7 48,7 65

     ∆p (kPa) 26,8 21,8 15,3Ф (l/h) 3874 3462 2857

    20 47,1 73,3 49 65,,7 52,2 54,4

     ∆p (kPa) 19,1 15,6 14,9Ф (l/h) 3221 2886 2393

    55° / 45°

    0 27,4 73,3 29,2 65,4 32,2 53,8

     ∆p (kPa) 63,2 51,2 35,7Ф (l/h) 6395 5707 4697

    10 31,8 58,5 33,2 52,2 35,7 43,1

     ∆p (kPa) 41,7 33,7 26,9Ф (l/h) 5107 4552 3763

    20 36,2 43,8 37,3 39,1 39,1 32,2

     ∆p (kPa) 27,7 22,5 15,8Ф (l/h) 3820 3417 2815

  • 8/16/2019 Air Curtains7prfhz0j

    11/25

    AIR CURTAINS GRAND / SONATA

    413Design changes reserved

    Q **[kW]

    Air temperature increase Air flow rate [m3/h] Max. current [A]

    ModelInstallationheight[m]

    Type Vent. Heater

    GRAND2510

    2,5

    N - - - -

    1700 1550 1300

    1,1 -

    E31,5 3,3 4,1 6,1

    1,1 4,53 6,5 8,3 6,1**

    E63 6,5 8,2 12,3

    1,1 9,16 13,1 16,4 12,3**

    GRAND2517

    N - - - -

    2650 2100 1500

    1,5 -

    E5

    2,5 3 3,7 4,5

    1,5 7,65 6,1 7,4 4,5**

    E105 6,1 7,4 9,1

    1,5 15,210 12,1 14,9 9,1**

    GRAND2520

    N - - - -

    3400 3100 2600

    1,5 -

    E64 7 4,5

    1,5 9,16 6,1 7,4 4,5**

    E1210 6,1 7,4 9,1

    1,5 18,212 1,1 14,9 9,1**

    GRAND3510

    3,5

    N - - - -

    2700 1750 1300

    2,4 -

    E63 3,9 6,2 9,9

    2,4 9,16 7,9 12,3 9,9**

    E93 3,9 6,2 9,9

    2,4 13,6

    6 11,8 18,5 9,9**

    GRAND3517

    N - - - -

    4000 2250 1400

    3,6 -

    E105 4,1 8,2 12,6

    3,6 15,210 8,2 16,4 12,6**

    E155 4,1 8,2 12,6

    3,6 22,710 12,3 24,6 12,6

    GRAND3520

    N - - - -

    5400 3500 2600

    6 -

    E126 4,1 8 1,6

    6 18,212 8 16,4 1,6**

    E1812 4,1 8 1,6

    6 27,618 1 4,6 1,6

    GRAND4510

    4,5

    N - - - -

    4300 3500 2700

    5,0 -

    E96 4,6 5,8 7,6

    5,0 13,69 6,9 8,7 7,6**

    E126 4,6 5,8 7,6

    5,0 18,212 9,2 11,6 7,6**

    GRAND4517

    N - - - -

    6500 5800 4500

    6,6 -

    E1510 5,1 6,2 7,8

    6,6 22,715 7,6 9,3 7,8**

    E2010 5,1 6,2 7,8

    6,6 30,315 10,1 12,4 7,8**

    GRAND4520

    N - - - -

    8600 7000 5400

    6,6 -

    E1812 5,1 6 7,8

    6,6 27,618 7,6 9 7,8**

    E2418 5,1 6 7,8

    6,6 36,924 10,1 1,4 7,8**

    (*) Numbers with the E mark represent the maximum heat output of a particular air curtain model; e.g. Grand 2510E2 represents a device withinstalled power of 2 (kW). The table shoes the electric heater power of each model in two levels - according to the control panel.(**) When selecting the lowest velocty, the device automatically reduces the heater run to the first level.

    Heat output and air temperature increase with electric air heating

    Description

    Q - heat output / electric heater rated power   - fan speed controller on control panel

  • 8/16/2019 Air Curtains7prfhz0j

    12/25

    AIR CURTAINS GRAND / SONATA

    414Design changes reserved

    Dimensions

    Dimensions [mm] Mass [kg]

    Model A B C D E F G Type (N) Type (E) Type (W)

    GRAND 2510 1005 270 400 55 900 50 R 3/4’’ 38 41 45

    GRAND 2517 1700 270 400 55 1595 50 R 3/4’’ 57 62 69

    GRAND 2520 2000 270 400 55 50 R 3/4’’ 57 62 69

    GRAND 3510 1005 350 500 55 900 50 R 3/4’’ 50 57 63

    GRAND 3517 1700 350 500 55 1595 50 R 3/4’’ 70 78 87

    GRAND 3520 2000 350 500 55 x 50 R 3/4’’ 70 78 87

    GRAND 4510 1005 400 600 455 900 60 R1’’ 60 67 74

    GRAND 4517 1700 400 600 455 1595 60 R1’’ 82 91 101

    GRAND 4520 2000 400 600 455 x 60 R1’’ 82 91 101

  • 8/16/2019 Air Curtains7prfhz0j

    13/25

    AIR CURTAINS GRAND / SONATA

    415Design changes reserved

    Ceiling installation

    Dimensions

    L

    B

    H

    B

              2          2

              3          3

    797,5

    2    5    5   

     3   1    3   

    50 120

    Grand CassetteL

    [mm]B

    [mm]H

    [mm]Suspension No.

    2510 1066 717 270 2 (900 mm)

    2517 1766 717 270 3 (947 mm)

    2520 2066 717 270 3 (947 mm)

    3510 1066 886 350 2 (900 mm)

    3517 1766 886 350 3 (947 mm)

    3520 2066 886 350 4 (632 mm)

    4510 1066 998 401 2 (900 mm)

    4517 1766 998 401 3 (947 mm)

    4520 2066 998 401 4 (632 mm)

  • 8/16/2019 Air Curtains7prfhz0j

    14/25

    AIR CURTAINS GRAND / SONATA

    416Design changes reserved

    Sonata series

    SONATA series air curtains as a part of the Klimaoprema QuantLine program are meant for installation in spaces with highestetic requirements. With their oval casing and inbuilt halogenlamps the curtains will elegantly fit into facilities such ashotels, banks, showrooms etc. Apart from white colour (RAL

    9010), casings come in red (RAL 2000), yellow (RAL 1021) andgrey (RAL 9006) metallic colour.SONATA series air curtains are represented by models 2510i 2517 with hot water (W) or an electric (E) heater. At specialrequest devices without a heater (N) are also available.

    Air flow, noise, heat output with a hot water heater and supply air temperature

    Model TypeAir flow rate

    (m3 /h)Sound power level

    (dB(A))Current (A)

    (max)Power supply

    V/Ph/Hz

    SONATA 2510

    N 1700 1550 1300 1,1220/1/50

    W 1600 1400 1100 54 50 43

    E 1700 1550 1300 10,2 400/+N/50

    SONATA 2517

    N 2650 2100 1500 1,5220/1/50

    W 2500 1900 1200 56 53 48

    E 2650 2100 1500 17,0 400/+N/50

    SONATA 2520

    N 3400 3100 2600 1,5220/1/50

    W 3200 2800 2200 59 55 50

    E 3400 3100 2600 20,1 400/+N/50

  • 8/16/2019 Air Curtains7prfhz0j

    15/25

    AIR CURTAINS GRAND / SONATA

    417Design changes reserved

    SONATA 2510W

      Air flow rate (m³/h)

    TU / T

    Itu (°C)

    1600 1400 1100

    ti(°C) Q (kW) ti(°C) Q (kW) ti(°C) Q (kW)

    90° / 70°

    0 32,9 17,5 34,6 16,3 37,5 14,3

     ∆p (kPa) 4,3 3,8 3,0

    Ф (l/h) 773 719 632

    10 38,5 15,2 40,0 14,3 42,5 12,4

     ∆p (kPa) 3,3 2,9 2,3

    Ф (l/h) 670 623 549

    20 44,1 12,8 45,3 12,0 47,4 10,5

     ∆p (kPa) 2,4 2,1 1,7Ф (l/h) 566 528 456

    80° / 60°

    0 28,1 15,0 29,5 13,9 32,1 12,2

     ∆p (kPa) 3,3 2,8 2,2Ф (l/h) 657 612 538

    10 33,7 12,6 34,9 11,7 37,0 10,3

     ∆p (kPa) 2,4 2,1 1,6Ф (l/h) 554 516 454

    20 39,2 10,2 40,2 9,6 41,87 8,4

     ∆p (kPa) 1,6 1,4 1,1Ф (l/h) 451 420 370

    55° / 45°

    0 20,5 10,9 21,5 10,2 23,33 8,9

     ∆p (kPa) 6,9 5,9 4,7Ф (l/h) 952 885 777

    10 26,1 8,6 26,8 8,0 28,3 7,0

     ∆p (kPa) 4,3 3,8 3,0Ф (l/h) 746 694 610

    20 31,5 6,2 32,1 5,7 33,1 5,1

     ∆p (kPa) 2,3 2,1 1,6Ф (l/h) 538 501 441

    SONATA 2517W

      Air flow rate (m³/h)

    TU / T

    Itu (°C)

    2500 1900 1200

    ti(°C) Q (kW) t

    i(°C) Q (kW) t

    i(°C) Q (kW)

    90° / 70°

    0 36,8 30,8 40,9 25,9 48,5 18,6

     ∆p (kPa) 17,4 12,6 6,8

    Ф (l/h) 1361 1142 821

    10 42,1 26,9 45,6 22,6 52,22 16,2

     ∆p (kPa) 13,6 9,8 5,3

    Ф (l/h) 1187 9979 717

    20 47,3 23,0 50,28 19,3 55,88 13,9 ∆p (kPa) 10,1 7,3 3,9Ф (l/h) 1013 852 613

    80° / 60°

    0 31,7 26,6 35,3 22,3 41,8 16,1

     ∆p (kPa) 13,5 9,7 5,3Ф (l/h) 1169 981 706

    10 37,0 22,6 40,0 19,0 45,56 13,7

     ∆p (kPa) 10 7,2 3,9Ф (l/h) 995 836 601

    20 42,2 18,7 44,6 15,7 49,2 11,3

     ∆p (kPa) 7,0 5,1 2,8Ф (l/h) 820 690 497

    55° / 45°

    0 22,9 19,2 25,5 16,1 30,2 11,6

     ∆p (kPa) 27,7 20,0 10,9Ф (l/h) 1677 1406 1010

    10 28,2 15,3 30,17 12,8 33,9 9,2 ∆p (kPa) 18,1 13,1 7,1Ф (l/h) 1330 1116 802

    20 33,3 11,2 34,8 9,4 37,52 6,8

     ∆p (kPa) 10,3 7,4 4,1Ф (l/h) 980 823 592

  • 8/16/2019 Air Curtains7prfhz0j

    16/25

    AIR CURTAINS GRAND / SONATA

    418Design changes reserved

    SONATA 2520W

      Air flow rate (m³/h)

    TU / T

    Itu (°C)

    2500 1900 1200

    ti(°C) Q (kW) ti(°C) Q (kW) ti(°C) Q (kW)

    90° / 70°

    0 36,8 30,8 40,9 25,9 48,5 18,6

     ∆p (kPa) 17,4 12,6 6,8

    Ф (l/h) 1361 1142 821

    10 42,1 26,9 45,6 22,6 52,22 16,2

     ∆p (kPa) 13,6 9,8 5,3

    Ф (l/h) 1187 9979 717

    20 47,3 23,0 50,28 19,3 55,88 13,9

     ∆p (kPa) 10,1 7,3 3,9Ф (l/h) 1013 852 613

    80° / 60°

    0 31,7 26,6 35,3 22,3 41,8 16,1

     ∆p (kPa) 13,5 9,7 5,3Ф (l/h) 1169 981 706

    10 37,0 22,6 40,0 19,0 45,56 13,7

     ∆p (kPa) 10 7,2 3,9Ф (l/h) 995 836 601

    20 42,2 18,7 44,6 15,7 49,2 11,3

     ∆p (kPa) 7,0 5,1 2,8Ф (l/h) 820 690 497

    55° / 45°

    0 22,9 19,2 25,5 16,1 30,2 11,6

     ∆p (kPa) 27,7 20,0 10,9Ф (l/h) 1677 1406 1010

    10 28,2 15,3 30,17 12,8 33,9 9,2

     ∆p (kPa) 18,1 13,1 7,1Ф (l/h) 1330 1116 802

    20 33,3 11,2 34,8 9,4 37,52 6,8

     ∆p (kPa) 10,3 7,4 4,1Ф (l/h) 980 823 592

    Description:

    Tu /T

    i- inlet/outlet water temperature

     tu  - intake air temperature

     ti  - exit air temperature

    Q - heat output ∆p

    w  - pressure drop on water side

    Φ  - heat exchanger water flow rate  - fan speed controller on control panel

  • 8/16/2019 Air Curtains7prfhz0j

    17/25

    AIR CURTAINS GRAND / SONATA

    419Design changes reserved

    Heat output and air temperature increase with electric air heating

    Model Type Q **[kW]Air temperature increase Air flow rate [m3 /h] Max. current [A]

    Vent. Heater

    SONATA2510

    N - - - -

    1700 1550 1300

    1,1 -

    E31,5 3,3 4,1 6,1

    1,1 4,53 6,5 8,3 6,1**

    E63 6,5 8,2 12,3

    1,1 9,16 13,1 16,4 12,3**

    SONATA2517

    N - - - -

    2650 2100 1500

    1,5 -

    E52,5 3 3,7 4,5

    1,5 7,65 6,1 7,4 4,5**

    E105 6,1 7,4 9,1

    1,5 15,2

    10 12,1 14,9 9,1**

    SONATA2520

    N - - - -

    3400 3100 2600

    1,5 -

    E64 7 4,5

    1,5 9,16 6,1 7,4 4,5**

    E1210 6,1 7,4 9,1

    1,5 18,212 1,1 14,9 9,1**

    Dimensions [mm] Mass [kg]

    Model A B Type (N) Type (E) Type (W)

    SONATA 2510 1084 900 54 57 6

    SONATA 2517 1779 1595 76 84 90

    SONATA 2520 2079 1595 76 84 90

    (*) Numbers with the E mark represent the maximum heat output of a particular air curtain model; e.g. Sonata 2510E2 represents adevice with installed power of 2 (kW). The table shows the electric heater power of each model in two levels - according to the control panel.(**) When selecting the lowest velocty, the device automatically reduces the heater run to the first level.

    Dimensions

    Description

    Q - heat output / electric heater rated power 

      - fan speed controller on control panel

    * Dimension for model Sonata 2520

  • 8/16/2019 Air Curtains7prfhz0j

    18/25

    AIR CURTAINS GRAND / SONATA

    420Design changes reserved

    Control

    GRAND and SONATA air curtains are controlled by a control panelplaced on a wall. The panel below outlines all available functions.

    Depending on a series (GRAND/SONATA) or a device type (hotwater/electric heater) some buttons may be left out.

    After assembling the control panel according to the given schemeand connecting it to the corresponding voltage, red LED next to the main switch ON/OFF flashes. The switch ON/OFF switches thedevice ON/OFF. Mode selection is initiated by pressing the button

    PROGRAMME. In general, there are two modes available - manualand automatic.

    • The manual mode provides triple speed run fun bypressing the button PROGRAMME. Air curtains with electric

    heaters are equipped with two heater power levels initiated by thebutton HEATER. When the device runs at the lowest speed, thesecond heater level is automatically reduced to the first level.

    • Automatic mode reflects in connection to the door openingswitch. It means that the device reacts to opening the door abovewhich it is installed. There are two installation modes:

    Button for switching on/off halogen bulbs (SONATA series)

    Signal LED - halogen bulbs switched on

    Button for switching on/off electric heaters

    Signal LED - heaters switched off

    Signal LED - first level of heater power 

    Signal LED - second level of heater power 

    Signal LED - see “Automatic mode” under (b)

    Signal LED - see “Automatic mode” under (a)

    Signal LED - highest fan speed

    Signal LED - average fan speed

    Signal LED - lowest fan speed

    Button for mode selection

    Signal LED - device switched off

    Main switch for switching off/on the device

  • 8/16/2019 Air Curtains7prfhz0j

    19/25

    AIR CURTAINS GRAND / SONATA

    421Design changes reserved

    a.  In the automatic mode denoted by the symbol ( ) the devicekeeps being switched off until the door opens. Then, it is actuatedat a maximum fan speed and remains active for 30 sec after thedoor closes. If the door during those 30 sec opens again, the de-vice keeps running at the maximum speed until the next door clos-

    ing after which it waits for another 30 sec to be switched off. Sucha mode enables energy-saving since the device remains switchedoff while the door is being closed.

    b. In the automatic mode denoted by the symbol ( ) the device runsat the first fan speed. When the door opens, the third (maximum)fan speed is actuated and, like in case under (a.), the maximumfan speed remains switched on for 20 sec after the door closes.If the device is supplied with electric heaters, this mode sets thedevice into the continuous first heater level run. the mode providescontinuous heating of the room which air cur tains are installed into.

    When switching off the device (switch ON/OFF) supplied withelectric heaters, the ventilator (fan) keeps running for another 60sec in order to cool electric heaters - if the heaters have beenpreviously turned on. Also, the mode prior to switching off is memorized,

    so that it is actuated again when the device is switchedon for the next time. The buton LIGHT is intended for switching on/off halogen bulbs (2x20W) regarding SONATA seriesand it does not depend on a main switch position ON/OFF.In case of multiple air curtain installation one control panel canbe connected up to 16 devices according to the enclosedelectrical shemes.

    Control panel dimensions:

    Through the installed adjustable blades on the supply air opening, it is possible to direct the air flow.

  • 8/16/2019 Air Curtains7prfhz0j

    20/25

    AIR CURTAINS GRAND / SONATA

    422Design changes reserved

    The regulation of hot water air curtains is carried out withregard to the supply air temperature and room temperature.The supply air temperature is set in the device itself in the

    range from 30° to 50°C. The desired room temperature isset on a room thermostat which is connected to the controlpanel. When doing so, the position of the room thermostatdoes not have to be compatible with the position of the controlpanel but it should be placed in accordance with the manual

    for the relevant room temperature measuring. Based on the temperature settings stated here in above, the automaticcontrol of hot water air curtains regulates the electrothermic

    actuator. The actuator contains ON/OFF control but due toa long period during which the valve remains shut (about 2minute) the valve regulation is almost continuous.

    The scheme below shows two modes of hot water regulation:

      (a) air curtains in the heating system,  (b) air curtains in the heating and cooling system.

    Thermal regulation

    The difference from the first case reflects in the presence of anadjoining changeover thermostat. The air curtains with water heatexchanger are not designed for air cooling, so it is inevitable tostop water flow through the device in the cooling period. Measur-ing the supply pipe temperature a changeover thermostat detects

     the winter (heating) and summer (cooling) period. If the water  temperature decreases below 19°C, the thermostat switches off the electrothermic actuator which, then, shuts the valve. If thewater temperature incereases above 30°C the thermostat is actu-ated again. A changeover thermostat has to be placed on a pipewith regular water flow, which, in mosta cases, means the use ofa switch valve. If it is not in case, once the valve is switched off, itcould not be switched on again. However, in such cases the useof a straight way valve (control valve) is possible if next to it there

    is the main pipeline with continuous water flow which a change-over thermostat would be placed onto. The actuator site does notnecessarily have to be next to the device but it can be hidden in asuspend ceiling or displaced in another room where it will not es- thetically disturb the installation site. The regulation of air curtains

    with electric heaters is carried out only in regard with the room temperature, which requires the installation of a room thermostatand its connection to the control panel according to the corre-sponding electrical schemes. All additional elements necessaryfor the thermal regulation of air curtains are shown in the sectionADDITIONAL EQUIPMENT.

    (a) (b)

  • 8/16/2019 Air Curtains7prfhz0j

    21/25

    AIR CURTAINS GRAND / SONATA

    423Design changes reserved

    Free hanging and ceiling installation

    Discharge display

  • 8/16/2019 Air Curtains7prfhz0j

    22/25

  • 8/16/2019 Air Curtains7prfhz0j

    23/25

    AIR CURTAINS GRAND / SONATA

    425Design changes reserved

    Working conditions package, transport and storage

    Air curtains are designed for installation and work in dry interiorswith a temperature from -10 to +40˚C and air pollutant amount(dust, chemical vapour)within the valid standards for occupied

    zones.

    Air curtains are initally wrapped in PE foil and then put into card-board package supported by Styrofoam/cardboard inserts. Thepackage is used exclusively for protection during transportation to installation sites and may be removed only immediately beforeinstallation.

    If a device in package falls down, it can be damaged. Therefore,device transportation shall be protected from

    downfalls and rolling. Air curtains may only be lifted by especiallydesigned (forklift, crane) devices with a focus on their capacity.The data on the weight of particular air cuirtains model are

    stated in this manual.In case of transportation damage one should report it to aresponsible shipping company. If there is a suspicion of damage, the device must not be used. Air curtains may be stored only inrooms protected from external influences with a maximum paletteheight of 1.5 m.

    Accessories

    Following accessories are available for air curtains:

    Šifra Naziv Šifra Naziv

    ZZ-M1 Upravljač rada zračnih zavjesa   ZZ-M6 „Changeover“ termostat

    ZZ-M 2 Sobni termostat   ZZ-M7 Gibljiva spojnica(naznačiti 3 /4’’ ili 1’’)

    ZZ-M 3 Prolazni ravni ventil(naznačiti 3 /4’’ ili 1’’)

    ZZ-M8 Navojne šipke M8 s prijelaznim maticama

    ZZ-M4 Razdjelni ventil (naznačiti 3 /4’’ ili 1’’)   ZZ-M9 Sklopka otvaranja vrata

    ZZ-M5 Elektrotermički pogon ventila

    Code Name Code Name

    Air curtain controller “Changeover” thermostat

    Room thermostat Flexibile coupling(select 3/4” or 1”)

    Flat valve(select 3/4” or 1”)

    Thread rod M8 with coupling nuts

    Split valve (select 3/4” or 1”) End switch

    Electrothermic valve drive

  • 8/16/2019 Air Curtains7prfhz0j

    24/25

    AIR CURTAINS GRAND / SONATA

    426Design changes reserved

    Wiring scheme

    Grand /Sonata ( hot water heater) Grand /Sonata ( hot water heater)

    Electrothermic

     valve drive

    Power supply

    Door endswitch

    If room thermostat is notinstalled, shortbypass should beinstalled

    Power supply

    Electrothermic

     valve drive

    Up to 16 devices

    Controller unit Room thermostat

    Grand /Sonata ( electric heater) Grand /Sonata ( electric heater)

    Power supply Power supply

    Up to 16 devicesIf room thermostat is notinstalled, shortbypass should beinstalled

    Door endswitch

    Controller unit Room thermostat

  • 8/16/2019 Air Curtains7prfhz0j

    25/25

    AIR CURTAINS GRAND / SONATA

    NOTES: