Air-Cooled Condensing Units - Realcold - People … · Air-Cooled Condensing Units Milk Vats RMV...
Transcript of Air-Cooled Condensing Units - Realcold - People … · Air-Cooled Condensing Units Milk Vats RMV...
Air-Cooled Condensing Units
Milk Vats
RMV Units Custom Designed & Built for On-Farm Refrigeration
Applications
Features
Air-Cooled Condensing Units
• Theseunitshavebeenspecificallydevelopedforon-farm
refrigerationofmilkvats.
• Single,TwinorTriplemultiplexedcompressorsofferingstaged
capacitycontroloverawiderangeofapplications.
• 6sizes,coveringcapacitiesfrom11to36Kw.
• ASERCOMcompressorcertification,assuringindependent
verificationofpublishedperformancecapacityfigures.
•Horizontialairflow.
• Performanceratedatupto55degreescondensing
temperature.
ADDITIONAL OPTIONS•Desuperheaterplateheatexchangerforwaterheatrecovery.
Leavingwatertemperatureofupto60°Corgreatercanbe
achieved.
• Chilledwaterheatexchangerkitforprechillingmilk.Applyto
TechnicalDepartmentfordetails.
• 300mmhighextendedsupportlegs(refertoimageontheleft).
•OptionalWeatherShieldforoutdooruse.
Seenextpageforfurtherdetails
COMPRESSOR• Eachhighefficiencyhermetictypecompressorishermetically
sealed,quietrunningandsupportedonrubbermountsto
minimisevibration.
COOLING CAPACITY• CoolingCapacityRated@2°CSST/45°CSCT/32°CAmbient
onR404Arefrigerant.
REFRIGERATION PIPING•Thestandardunitallowsforalinelengthofupto30m.
WIRING•Electricalsupplyrequired(includingvoltagefluctuationlimits):
3phase342-436Va.c.50Hzwithneutralandearth.Acontrol
panellocatedintheoutdoorunitisfullywired,readytoaccept
themainpowersupply.
SAFETY Features•HP/LPswitchandanantirapidcycletimerforcompressor
protection.Thecompressoralsohasinternaloverload
protection.
•Circuitbreakercontrolcircuits.
Themanufactureroperatesaqualitymanagement
systemthatconformstoAS/NZS ISO 9001:2000
Model Nominal Duty kW Nominal Herd Size Vat Size for Daily Pickup
Unit Selection Guide
Additional Options
Nominal Capacities @ 2°C SST/ +45°C SCT R404a
All models are 380-415V 3PH 50Hz
Nominal Herd and Vat Sizes based on:• 22 Lt/cow per day
• 55% morning, 45% afternoon milking
• Nominal 4 hour pulldown (3 hour from completion of milking)
• Milk ∆ T = 13°C
NOTE: Materials and specifications are subject to change without notice due to ongoing research and development program
• Full Desuperheater duties based on EWT 20°C LWT 60°C on
R404a refrigerant.
• Normal Desuperheater duties based on EWT 20°C LWT 40°C on
R404a refrigerant.”
Water Heating Options
Weather Shield Options
Support Leg Options
RMV450 11.4 250 cows 5700 litres
RMV600 15.1 300 cows 6800 litres
RMV900 22.0 400 cows 9100 litres
RMV1000 25.1 500 cows 12000 litres
RMV1200 31.9 550 cows 15000 litres
RMV1500 36.3 900 cows 21500 litres
OHC15-20 OMC60-20 RMV 450 5
OHC15-20 OMC60-20 RMV 600 6.3
OHC15-20 OMC60-20 RMV 900 8.3
OHC15-20 OMC60-30 RMV 1000 11
OHC15-20 OMC60-30 RMV 1200 12.4
OHC15-30 OMC60-40 RMV 1500 18.2
C1940 Easypack W/Shield RMTZ112-150
C1941 Easypack W/Shield RMTZ175-X300
C1942 Easypack W/Shield RMTZX450-600
C1943 Easypack W/Shield ZX900T-1200T
C1944 Easypack W/Shield RMTZX1500T
D0175 Realcold Corner Leg
D0176 Realcold Centre Leg
Realcold Stock No. Normal Desuperheaters
Realcold Stock No. Full Size Desuperheaters
Model Hot Water Heating Capacity kW*
Realcold Stock No. Description
Realcold Stock No. Description
Specifications
Diagrams
REALCOLD RMV450 & 600
DESCRIPTION RMV450 RMV600
RMTXZ450
TAG4553Z
4.5
11.4 kW
380-420V 3PH 50Hz
8.75 A
14.35 A
2 x 220-240V 0.8A 1PH 50Hz
118 Kg
22mm (12mm)
RMTXZ600
TAG4573Z
6.25
15.1 kW
380-420V 3PH 50Hz
12.35 A
19.0 A
2 x 220-240V 0.8A 1PH 50Hz
135 Kg
22mm (12mm)
Base Unit
Compressor - Tecumseh
Nominal Horsepower
Cooling Capacity *
Power Supply
Compressor Run Amps
Starting Amps
Condenser Fan
Weight Approx (dry)
Recommended Pipe Sizes
* Cooling Capacity Rated @ 2°C SST / 45°C SCT / 32°C Ambient on R404A refrigerant
Specifications
REALCOLD RMV900 & 1000
DESCRIPTION RMV900 RMV1000
RMTXZ900T
2 x TAGP4553Z
9
22.0 kW
380-415V 3PH 50Hz
16.2 A
25.5 A
2 x 380V 0.9A 3PH 50Hz
213 Kg
28mm (16mm)
RMTXZ1000T
2 x TAGP4561Z
10
25.1 kW
380-415V 3PH 50Hz
19.5 A
25.5 A
2 x 380V 0.9A 3PH 50Hz
218 Kg
28mm (16mm)
Base Unit
Compressor - Tecumseh
Nominal Horsepower
Cooling Capacity *
Power Supply
Compressor Run Amps
Starting Amps
Condenser Fan
Weight Approx (dry)
Recommended Pipe Sizes
* Cooling Capacity Rated @ 2°C SST / 45°C SCT / 32°C Ambient on R404A refrigerant
Diagrams
Specifications
REALCOLD RMV1200
* Cooling Capacity Rated @ 2°C SST / 45°C SCT / 32°C Ambient on R404A refrigerant
Diagrams
DESCRIPTION RMV1200
Base Unit
Compressor - Tecumseh
Nominal Horsepower
Cooling Capacity *
Power Supply
Compressor Run Amps
Starting Amps
Condenser Fan Amps
Weight Approx (dry)
Recommended Pipe Sizes
RMTXZ1200T
2 x TAGP4573Z
12
31.9 kW
380-415V 3PH 50Hz
23.9 A
39.0 A
2 x 380V 0.9A 3PH 50Hz
218 Kg
28mm (16mm)
* Cooling Capacity Rated @ 2°C SST / 45°C SCT / 32°C Ambient on R404A refrigerant
Diagrams
DESCRIPTION RMV1500
Base Unit
Compressor - Tecumseh
Nominal Horsepower
Cooling Capacity *
Power Supply
Compressor Run Amps
Starting Amps
Condenser Fan Amps
Weight Approx (dry)
Recommended Pipe Sizes
RMTXZ1500T
3 x TAGP4561Z
15
36.3 kW
380-415V 3PH 50Hz
27.0 A
153.0 A
2 x 380V 0.9A 3PH 50Hz
300 Kg
28mm (16mm)
Specifications
REALCOLD RMV1500
AUCKLAND BRANCH / HEAD OFFICE9PrescottStreet,Penrose1061POBox12072,Penrose1642OrdersDirectFax:095265748Phone:095265700Fax:095265721Email:[email protected]
NORTH HARBOURUnitC,28CanaveralDrive,Albany0632POBox305354,TritonPlazaNorthShoreCity0757Phone:094770274Fax:094782309Email:[email protected]
WHANGAREI / NORTHLANDUnitA1,7-11NellPlace,Raumanga,Whangarei0110POBox25056,WhangareiMailCentreWhangarei0148Phone:094304476Fax:094307465Email:[email protected]
HAMILTON43LakeRoad,Frankton,Hamilton3204POBox5238,Frankton,Hamilton3242Phone:078482111Fax:078482333Email:[email protected]
TAURANGA5BarberryStreet,Judea,Tauranga3110POBox15610,Tauranga3144Phone:075710096Fax:075710097Email:[email protected]
PALMERSTON NORTHUnit2,597-599TremaineAve,PalmerstonNorth4410POBox4368,ManawatuMailCentre,PalmerstonNorth4442Phone:063579101Fax:063579103Email:[email protected]
HAWKES BAY / HASTINGSCnrStAubynStreetEast&MillerStreet,Hastings4122POBox488,Hastings4156Phone:068703714Fax:068703726Email:[email protected]
WELLINGTON54FitzherbertStreet,Petone, LowerHutt5012POBox38527,WellingtonMailCentre,LowerHutt5045Phone:045693072Fax:045682210Email:[email protected]
CHRISTCHURCH71HarmanStreet,Addington, Christchurch8024POBox9150,TowerJunction, Christchurch8149Phone:033388084Fax:033389938Email:[email protected]
DUNEDIN18RobertsStreet,Dunedin9016POBox2536,Dunedin9044Phone:034677106Fax:034677107Email:[email protected]
www.realcold.co.nzOrders Phone 0800 11 66 90
Realcold Limited reserves the right to change specifications without notice.© Realcold Limited, VI, May 2011