Air Conditioners Technical Data - Atec.ro DAIKIN FVXS25FV1B.pdf · Note) 1. The mark (Y) shows...

13
FVXS-F Floor Standing Unit Air Conditioners Technical Data www.daikin.eu

Transcript of Air Conditioners Technical Data - Atec.ro DAIKIN FVXS25FV1B.pdf · Note) 1. The mark (Y) shows...

Page 1: Air Conditioners Technical Data - Atec.ro DAIKIN FVXS25FV1B.pdf · Note) 1. The mark (Y) shows piping direction Main unit fixed screws 666(half concealed) Operation lamp Timer lamp

FVXS-F

F l o o r S t a n d i n g U n i t

Air Conditioners

Technical Data

w w w . d a i k i n . e u

Page 2: Air Conditioners Technical Data - Atec.ro DAIKIN FVXS25FV1B.pdf · Note) 1. The mark (Y) shows piping direction Main unit fixed screws 666(half concealed) Operation lamp Timer lamp

FVXS-F

F l o o r S t a n d i n g U n i t

Air Conditioners

Technical Data

w w w . d a i k i n . e u

Page 3: Air Conditioners Technical Data - Atec.ro DAIKIN FVXS25FV1B.pdf · Note) 1. The mark (Y) shows piping direction Main unit fixed screws 666(half concealed) Operation lamp Timer lamp

• Split Sky Air • Indoor units 1

• Indoor units • R-410A • FVXS-FV1B

TABLE OF CONTENTSFVXS-FV1B

1 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

2 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

For indoor units only . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

3 Dimensional drawing & centre of gravity . . . . . . . . . . . . . . . . . . . . . . . . 5

Dimensional drawing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Centre of gravity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

4 Piping diagram. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

5 Wiring diagram. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Wiring diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

6 Sound data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

Sound pressure spectrum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

!

Page 4: Air Conditioners Technical Data - Atec.ro DAIKIN FVXS25FV1B.pdf · Note) 1. The mark (Y) shows piping direction Main unit fixed screws 666(half concealed) Operation lamp Timer lamp

• Indoor units • R-410A • FVXS-FV1B

• Split Sky Air • Indoor units2

1 Features

Indoor unit Split Sky FVXS-FV1B R-410A • Stylish design

• Flat front panel: its stylish appearance blends easily within any interior décor and is more easy to clean.

• Titanium apatite photocatalytic air purification filter

• Can be installed against a wall or recessed

• Dual air discharge flow for better air distribution

• ECONO mode decreases power consumption so that other appliances that need large power supply can be used

• Lightweight but sturdy design

optional 5 steps

standard Titanium apatite photocatalytic air purification

filter

Page 5: Air Conditioners Technical Data - Atec.ro DAIKIN FVXS25FV1B.pdf · Note) 1. The mark (Y) shows piping direction Main unit fixed screws 666(half concealed) Operation lamp Timer lamp

• Split Sky Air • Indoor units 3

• Indoor units • R-410A • FVXS-FV1B

2 Specifications

2-1 For indoor units only FVXS25FV1B FVXS35FV1B FVXS50FV1B

Nominal input (Indoor only)

Cooling kW 0.015 0.015 0.027

Heating kW 0.017

2-2 Technical Specifications FVXS25FV1B FVXS35FV1B FVXS50FV1B

Casing Colour White

Dimensions Packing Height mm 696 696 696

Width mm 786 786 786

Depth mm 286 286 286

Unit Height mm 600 600 600

Width mm 700 700 700

Depth mm 210 210 210

Weight Unit kg 14 14 14

Packed Unit kg 18 18 18

Heat Exchanger Dimensions Length mm 510 510 510

Nr of Rows 2 2 2

Fin Pitch mm 1.2 1.2 1.2

Nr of Stages 22 22 22

Tube type ø6.35 Hi-XU

Fin Type Multi slit fin

Fan Type Turbo fan

Quantity 1 1 1

Air Flow Rate Cooling High m³/min 8.2 8.5 10.7

Medium m³/min 6.5 6.7 9.2

Low m³/min 4.8 4.9 7.8

Silent Operation m³/min 4.1 4.5 6.6

Heating High m³/min 8.8

Medium m³/min 6.9

Low m³/min 5.0

Silent Operation m³/min 4.4

Fan Motor Quantity 1 1 1

Model D48D-28

Number of steps 5 5 5

Motor Speed (cooling) High rpm 640 650 800

Medium rpm 520 530 700

Low rpm 400 410 600

Silent Operation rpm 360 380 520

Speed (heating) High rpm 680

Medium rpm 550

Low rpm 420

Silent Operation rpm 380

Fan Motor Output (high) W 48 48 48

Cooling Sound Power High dBA 54 55 56

Sound Pressure High dBA 38 39 44

Medium dBA 32 33 40

Low dBA 26 27 36

Silent Operation dBA 23 24 32

Heating Sound Power High dBA 54

Sound Pressure High dBA 38

Medium dBA 32

Low dBA 26

Silent Operation dBA 23

Refrigerant Type R-410A

Piping connections Liquid (OD) Diameter (OD) mm 6.4 6.4 6.4

Gas Diameter (OD) mm 9.5 9.5 12.7

Drain Diameter (OD) mm 20 20 20

Heat Insulation Both liquid and gas pipes

Air Filter Removable/washable/Mildew proof

Air direction control Right, Left, Horizontal, Downward

Page 6: Air Conditioners Technical Data - Atec.ro DAIKIN FVXS25FV1B.pdf · Note) 1. The mark (Y) shows piping direction Main unit fixed screws 666(half concealed) Operation lamp Timer lamp

• Indoor units • R-410A • FVXS-FV1B

• Split Sky Air • Indoor units4

2 Specifications

Temperature control Microcomputer control

Standard Accessories Item Installation manual

Quantity 1 1 1

Item Operation manual

Quantity 1 1 1

Item Wireless remote control

Quantity 1 1 1

Item Batteries

Quantity 2 2 2

Item Remote control holder

Quantity 1 1 1

Item Drain hose

Quantity 1 1 1

Item Air supply filter

Quantity 1 1 1

Item Thermal insulation tape

Quantity 2 2 2

2-3 Electrical Specifications FVXS25FV1B FVXS35FV1B FVXS50FV1B

Power Supply Name V1

Phase 1 1 1

Frequency Hz 50 50 50

Voltage V 220-240

Current Nominal running current (RLA)

Cooling A 0.13 0.13 0.17

Heating A 0.14

Maximum Running Current A 0.15 0.14 0.18

Wiring connections For Power Supply Quantity 3 3 3

Remark 4 for interunit wiring (including earth wiring)

2-2 Technical Specifications FVXS25FV1B FVXS35FV1B FVXS50FV1B

Page 7: Air Conditioners Technical Data - Atec.ro DAIKIN FVXS25FV1B.pdf · Note) 1. The mark (Y) shows piping direction Main unit fixed screws 666(half concealed) Operation lamp Timer lamp

• Split Sky Air • Indoor units 5

• Indoor units • R-410A • FVXS-FV1B

3 Dimensional drawing & centre of gravity

3 - 1 Dimensional drawing

3D056135

FVXS25-35F unit (mm)

Main unit fixing screw

Note) 1. The mark (Y) shows piping direction

Main unit fixed screws

666 (half concealed)

Operation lamp

Timer lamp

Indoor unit ON/OFF switch

Signal receiver

Air outletselectionswitch(Inside)

Name plate

Drainsocket

Front panel fixed screws

Hole for splintHole for piping

Air flow

Required space

(formaintenance)

(forperformance)

(Wall hole)

Wall hole for half concealed

Terminal block with earthterminal

Liquid pipe (J6.4 CuT)

Gas pipe (J9.5 CuT)

Room temp. thermistor

Signal transmitter

Infrared remote control

Hole for splint

Hole for piping

Drain hose

Adjusting the air flow direction

Right/left (manual)

Upper air outlet

Lower air outlet

Upward air flowlimit (OFF)

Upward air flowlimit (ON)

Up/down (automatic)Heat

(Heat pump model)

Hole for piping

Forp

erfo

rman

ce

584

(hal

fcon

ceal

ed)

(Wal

lhol

e)

Front panel fixed screws(inside)

VP20I.D. J20O.D. J26L 220

50 MIN 50 MIN

Cooling / dry

A

Model name label

95 (Half concealed)

85

Cool, dry

3D056136

FVXS50F unit (mm)

Main unit fixing screw

Note) 1. The mark (Y) shows piping direction

Main unit fixed screws

666 (half concealed)

Operation lamp

Timer lamp

Indoor unit ON/OFF switch

Signal receiver

Air outletselectionswitch(Inside)

Name plate

Drainsocket

Front panel fixed screws

Hole for splintHole for piping

Air flow

Required space

(formaintenance)

(forperformance)

(Wall hole)

Wall hole for half concealed

Terminal block with earthterminal

Liquid pipe (J6.4 CuT)

Gas pipe (J12.7 CuT)

Room temp. thermistor

Signal transmitter

Infrared remote control

Hole for splint

Hole for piping

Drain hose

Adjusting the air flow direction

Right/left (manual)

Upper air outlet

Lower air outlet

Upward air flowlimit (OFF)

Upward air flowlimit (ON)

Up/down (automatic)Cooling / dry Heat

(Heat pump model)

Hole for piping

Forp

erfo

rman

ce

584

(hal

fcon

ceal

ed)

(Wal

lhol

e)

Front panel fixed screws(inside)

VP20I.D. J20O.D. J26L 220

50 MIN 50 MIN

A

Model name label

95 (Half concealed)

85

Cool, dry

Page 8: Air Conditioners Technical Data - Atec.ro DAIKIN FVXS25FV1B.pdf · Note) 1. The mark (Y) shows piping direction Main unit fixed screws 666(half concealed) Operation lamp Timer lamp

• Indoor units • R-410A • FVXS-FV1B

• Split Sky Air • Indoor units6

3 Dimensional drawing & centre of gravity

3 - 2 Centre of gravity

FVXS25-50F

4D056197A

Page 9: Air Conditioners Technical Data - Atec.ro DAIKIN FVXS25FV1B.pdf · Note) 1. The mark (Y) shows piping direction Main unit fixed screws 666(half concealed) Operation lamp Timer lamp

• Split Sky Air • Indoor units 7

• Indoor units • R-410A • FVXS-FV1B

4 Piping diagram

FVXS25-35FIndoor unit

Heat exchanger

Fan motorField piping

Field piping

Refrigerant flow

Cooling

Heating

Turbo fan

Thermistor onheat exchanger

Muffler assy

4D056137A

FVXS50FIndoor unit

Heat exchanger

Fan motorField piping

Field piping

Refrigerant flow

Cooling

Heating

Turbo fan

Thermistor onheat exchanger

Muffler assy

4D056138A

Page 10: Air Conditioners Technical Data - Atec.ro DAIKIN FVXS25FV1B.pdf · Note) 1. The mark (Y) shows piping direction Main unit fixed screws 666(half concealed) Operation lamp Timer lamp

• Indoor units • R-410A • FVXS-FV1B

• Split Sky Air • Indoor units8

5 Wiring diagram

5 - 1 Wiring diagram

FVXS25-50F

gField wiring

Outdoor

Indoor

R : Protective earthF1U : FuseH1P,H2P : Pilot lampM1F : Fan motorM1S : Swing motorM2S : Lower air outlet motorPCB1∼PCB4 : Printed circuit boardR1T,R2T : ThermistorS1∼S49 : ConnectorS1W : Operation switchS2W(4) : Upward air flow limit switchS4W : Air outlet selection switchX1M : Terminal stripE3 : Earth terminal (heat. ex)E4 : Earth terminal (shield plate)

Signalreceiver

Infrared remotecontrol

Transmissioncircuit

Rectifier

CAUTIONNote that operation will restartautomatically if the main power supplyis turned off and then back on again.

3D055953A

Page 11: Air Conditioners Technical Data - Atec.ro DAIKIN FVXS25FV1B.pdf · Note) 1. The mark (Y) shows piping direction Main unit fixed screws 666(half concealed) Operation lamp Timer lamp

• Split Sky Air • Indoor units 9

• Indoor units • R-410A • FVXS-FV1B

6 Sound data

6 - 1 Sound pressure spectrum

Oct

ave

band

soun

dpr

essu

rele

vel

dB:(0

dB=

0.00

02μ

bar)

Octave band center frequency (Hz)

FVXS25F (Cooling)

approximate thresholdhearing for continuousnoise

Legend

50Hz 220-240V (H)

50Hz 220-240V (L)

NOTE1 Operation noise differs with operation and ambient

conditions.

2 Measure in anechoic room

Location of microphone

3D056240A

Oct

ave

band

soun

dpr

essu

rele

vel

dB:(0

dB=

0.00

02μ

bar)

Octave band center frequency (Hz)

FVXS25F (Heating)

approximate thresholdhearing for continuousnoise

Legend

50Hz 220-240V (H)

50Hz 220-240V (L)

NOTE1 Operation noise differs with operation and ambient

conditions.

2 Measure in anechoic room

Location of microphone

3D056240A

Oct

ave

band

soun

dpr

essu

rele

vel

dB:(0

dB=

0.00

02μ

bar)

Octave band center frequency (Hz)

FVXS35F (Cooling)

approximate thresholdhearing for continuousnoise

Legend

50Hz 220-240V (H)

50Hz 220-240V (L)

NOTE1 Operation noise differs with operation and ambient

conditions.

2 Measure in anechoic room

Location of microphone

3D056239A

Oct

ave

band

soun

dpr

essu

rele

vel

dB:(0

dB=

0.00

02μ

bar)

Octave band center frequency (Hz)

FVXS35F (Heating)

approximate thresholdhearing for continuousnoise

Legend

50Hz 220-240V (H)

50Hz 220-240V (L)

NOTE1 Operation noise differs with operation and ambient

conditions.

2 Measure in anechoic room

Location of microphone

3D056239A

Page 12: Air Conditioners Technical Data - Atec.ro DAIKIN FVXS25FV1B.pdf · Note) 1. The mark (Y) shows piping direction Main unit fixed screws 666(half concealed) Operation lamp Timer lamp

• Indoor units • R-410A • FVXS-FV1B

• Split Sky Air • Indoor units10

6 Sound data

6 - 1 Sound pressure spectrum

Oct

ave

band

soun

dpr

essu

rele

vel

dB:(0

dB=

0.00

02μ

bar)

Octave band center frequency (Hz)

FVXS50F (Cooling)

approximate thresholdhearing for continuousnoise

Legend

50Hz 220-240V (H)

50Hz 220-240V (L)

NOTE1 Operation noise differs with operation and ambient

conditions.

2 Measure in anechoic room

Location of microphone

3D056238AO

ctav

eba

ndso

und

pres

sure

leve

ldB

:(0dB

=0.

0002

μba

r)Octave band center frequency (Hz)

FVXS50F (Heating)

approximate thresholdhearing for continuousnoise

Legend

50Hz 220-240V (H)

50Hz 220-240V (L)

NOTE1 Operation noise differs with operation and ambient

conditions.

2 Measure in anechoic room

Location of microphone

3D056238A

Page 13: Air Conditioners Technical Data - Atec.ro DAIKIN FVXS25FV1B.pdf · Note) 1. The mark (Y) shows piping direction Main unit fixed screws 666(half concealed) Operation lamp Timer lamp

Naamloze Vennootschap - Zandvoordestraat 300, B-8400 Oostende - Belgium - www.daikin.eu - BE 0412 120 336 - RPR Oostende

Daikin’s unique position as a manufacturer of air

conditioning equipment, compressors and refrigerants

has led to its close involvement in environmental issues.

For several years Daikin has had the intention to become

a leader in the provision of products that have limited

impact on the environment. This challenge demands the

eco design and development of a wide range of products

and an energy management system, resulting in energy

conservation and a reduction of waste.

Daikin Europe N.V. is participating in the EUROVENT

Certification Programme. Products are as listed in the

EUROVENT Directory of Certified Products.

Daikin products are distributed by:

EE

DE

N1

0-1

00

• 0

4/1

0 •

Co

py

rig

ht

Da

ikin

Th

e p

rese

nt

pu

blic

ati

on

su

pe

rse

de

s E

ED

EN

09

-10

0

Pre

par

ed

in B

elg

ium

by

Lan

no

o (

ww

w.la

nn

oo

pri

nt.

be

), a

com

pan

y w

ho

se c

on

cern

for

the

en

viro

nm

en

t is

se

t in

th

e E

MA

S an

d IS

O 1

40

01

sys

tem

s.

Re

spo

nsi

ble

Ed

ito

r: D

aik

in E

uro

pe

N.V

., Z

an

dv

oo

rde

stra

at

30

0,

B-8

40

0 O

ost

en

de

The present publication is drawn up by way of information only and does not constitute an offer binding

upon Daikin Europe N.V.. Daikin Europe N.V. has compiled the content of this publication to the best of its

knowledge. No express or implied warranty is given for the completeness, accuracy, reliability or fitness for

particular purpose of its content and the products and services presented therein. Specifications are subject

to change without prior notice. Daikin Europe N.V. explicitly rejects any liability for any direct or indirect

damage, in the broadest sense, arising from or related to the use and/or interpretation of this publication. All

content is copyrighted by Daikin Europe N.V..

EN_Split_Front_Back.pdf 2 28/05/2010 15:21:37