Air Board Program (RMP) Reporting System (R3) and User ... · PDF fileCalifornia Air Resources...

53
California Air Resources Board Refrigerant Management Program (RMP) Refrigerant Registration and Reporting System (R3) Updates and User Training December 12, 2016

Transcript of Air Board Program (RMP) Reporting System (R3) and User ... · PDF fileCalifornia Air Resources...

California Air Resources BoardRefrigerant Management Program (RMP)Refrigerant Registration and Reporting System (R3)Updates and User Training

December 12, 2016

Agenda

• Overview: Refrigerant Management Program (RMP)

• Overview: Refrigerant Registration and Reporting (R3) System

• Demonstration: • Service Records Data Entry• Annual Report Submittal and Fee Payment 

• New information

• Questions

RMP program web page: www.arb.ca.gov/rmp

R3: www.arb.ca.gov/rmp‐r3

RMP email help line: [email protected] 2

Commonly Used Terminology

• High‐GWP refrigerant – those with a global warming potential greater than or equal to 150.

• ODS – Ozone Depleting Substance

• Refrigeration systems• System size

• Small – more than 50 lbs., but less than 200 lbs.• Medium – 200 lbs. or more, but less than 2,000 lbs.• Large – 2,000 lbs. or more

• Facility size• Based on single largest refrigeration system on site

3

Commonly Used Terminology

• ALD – Automatic Leak Detection system

• Facility type• Refrigeration Facility – facility that uses refrigeration systems (most common facility type)

• Refrigerant Distributor/Wholesaler – sells refrigerant• Refrigerant Reclaimer – receives and reprocesses or disposes of used refrigerant

4

Overview

Refrigerant Management Program (RMP)

5

6https://www.arb.ca.gov/cc/rmp/rmp.htm

RMP Program OverviewApplicability

• Facility with a refrigeration system • Stationary, non‐residential • More than 50‐lbs of a high‐GWP refrigerant or an ODS 

refrigerant• Excludes comfort cooling, ammonia systems

• Distributors, Wholesalers, Reclaimers

• Any person who installs, services, or repairs a high‐GWP gas refrigeration or a/c system

7

RMP Overview Phase‐In Schedule

8

In effect for all Facilities

Due Annually By March 1

- Periodic leak inspections or ALD - Prompt leak repairs - On-site recordkeeping - Required service practices

- Large and Medium facilities (≥200 lbs.)report and pay fee

- Distributors, wholesalers, reclaimers report- Small facilities update registration

information

Overview

Refrigerant Registration and Reporting System (R3)http://www.arb.ca.gov/rmp‐r3

9

R3 OverviewService Records Data Entry WorkflowLarge and Medium facilities

• Enter Service Records• Required for all Large and Medium facilities• Leak inspections, leak repairs, other maintenance• ALD audits, calibrations, repairs, etc.

• Batch upload data from refrigerant management software

• Enter at any time

10

R3 OverviewAnnual Reporting WorkflowLarge and Medium facilitiesDistributors/WholesalersReclaimers

11

After January 1, but No later than March 1 (leak inspections can be entered throughout the year)

R3 OverviewAnnual Fee Payment WorkflowLarge and Medium facilities

12

R3 OverviewUser Reports

• Useful reports can be printed from the R3• Facility and system leak rates• Refrigerant losses• Facility and system leak repair history• Inspections by enforcement agencies

• Refrigerant loss means $$$ loss

13

R3 OverviewCommon Mistakes and Solutions

• Service records not entered • Required leak inspections

• Annual for Small systems at medium and large facilities• Every 3 months for Medium systems ~ every 90 days• When additional refrigerant added

• Leak repairs• ALD servicing• Other maintenance affecting refrigerant• If service records and leak inspections are not reported your facility may not be in compliance and could incur fines.

14

R3 OverviewCommon Mistakes and Solutions

• Incorrect refrigerant usage on the Annual Report• Report the annual summary of refrigerant purchased, used, and disposed.

• Invoice not created and/or sent with payment• Print and send a copy of the invoice along with the check to ARB at the address on the invoice

15

Demonstration

Refrigerant Registration and Reporting System (R3)Service Records Data EntryAnnual Report Submittal and Fee Payment

16

Manage Facility

17

Edit information button

Progress Status Bar

Registration Steps (1‐3) Reporting Steps (4‐6)

Registration video:  https://youtu.be/n‐SZ4IOcO10

Leak insp. & Service

Step #4

18

00

Leak Inspections and Service

19

Leak Inspections and Service

20

Leak Repair Service Records

21

Leak Inspections and Service

22

Leak Inspections and Service

23

ALD Service Records

24

ALD Service Records

25

R3 Reporting Aid – leak inspections

26https://www.arb.ca.gov/cc/rmp/r3‐registration‐checklist.pdf

Annual ReportsStep #5

27

Annual Reports

28

Annual Reports (page 1)

29

Verification

Refrigerant purchase and use

Annual Reports (page 2)

30

Confidentiality claim

Certification

Annual Fee Payment

31

Annual Fee Payment

32

Annual Fee PaymentGenerate Invoice Page

33

Annual Fee Payment

34

2015

Payment Invoice

35

Address to send payment

2015

Annual Fee Payment

36

2015

Online Credit Card Payment

37

Other Features

38

Sale or Closure of a Facility

39

Closure or Transfer of Facility

40

Shutdown of a Refrigeration System

41

Change Refrigerant Type

42

New information

43

Significant New Alternatives PolicySNAP• EPA refrigerant approval program

• Changes affect many refrigerants in specific sectors including R‐404A and R‐507A

44

End‐Use Substitutes Decision

Supermarket Systems (Retrofit)R‐404A, R‐407B, R‐421B, R‐422A,    R‐422C, R‐422D, R‐428A, R‐434A,    R‐507A

Unacceptable as of July 20, 2016

Supermarket Systems (New)HFC‐227ea, R‐404A, R‐407B,            R‐421B, R‐422A, R‐422C, R‐422D,      R‐428A, R‐434A, R‐507A

Unaccepable as of January 1, 2017

Remote Condensing Units (Retrofit)

R‐404A, R‐407B, R‐421B, R‐422A,     R‐422C, R‐422D, R‐428A, R‐434A,      R‐507A

Unaccepable as of July 20, 2016

Remote Condensing Units (New)HFC‐227ea, R‐404A, R‐407B, R‐421B, R‐422A, R‐422C, R‐422D, R‐428A, R‐434A, R‐507A

Unacceptable as of January 1, 2017

https://www.epa.gov/snap

U.S.EPA Rule 608 Amendments

• Amendments to the EPA refrigerant rule take effect on January 1, 2017

• Some of the major provisions changed include:

45

Provision Rule 608 ‐ Old Rule 608 Amendments ‐ New

Refrigerants affected ODS (CFCs and HCFCs) onlyODS and substitutes (CFCs, HCFCs, HFCs)

Leak rate threshold35% for commercial refrig and IPR, 15% for A/C

30% for IPR, 20% for commercial refrigeration, 10% for A/C

Periodic leak inspections Not required If exceed leak rate threshold

Chronic leaks No provisionFile report if leak more than 125% in calendar year

Computer roomsA/C for climate control to protect equipment including computer rooms

A/C is for comfort cooling only, computer rooms are refrigeration

Possible RMP Amendments

• ARB is considering amending the RMP regulation

• Some of the provisions being considered include:

46

Provision RMP Possible RMP Amendment

Chronic leaks No provisionRetire component or system if multiple large leaks per year

Technician responsibilitiesNo requirement other than required service practices

‐ Verify facility registration,               ‐ Provide facility with records equivalent to R3 recrodkeeping,       ‐ Retain records of service provided to facilities

Computer roomsA/C for climate control to protect equipment including computer rooms

A/C is for comfort cooling only, computer rooms are refrigeration

Reporting for Small facilitiesOne‐time registration only, no reporting required

Registration and abbreviated annual report

Global HFC Phasedown

• October 15, 2016• Montreal Protocol amended to include phasedown schedule for HFCs

• 2019 ‐ first step reduces consumption and production of HFCs by 10% below 2011‐2013 baseline

• 2036 ‐ last step reduces consumption and production of HFCs by 85% below 2011‐2013 baseline

47

Year Percent allocation

2019 90%

2024 60%

2029 30%

2036 15%

Includes many refrigerants  commonly used today such as;• R‐404A• R‐507A• R‐410A• R‐407 series

Short Lived Climate Pollutant Plan

• SB 1383 – 40% HFC reduction target• SLCP plan proposed to meet target

• Proposed measures:• HFC phase‐down (recently adopted globally)• New system refrigerant prohibitions• Sales ban of high‐GWP refrigerants• Incentive program to assist funding low‐GWP alternatives

• Start dates remain to be determined

48

More information ‐ http://www.arb.ca.gov/slcp

Low‐GWP options• Ammonia (low‐charge now available)

– Direct or secondary loop

• Carbon Dioxide (CO2)– Combine with new technologies to increase 

efficiency

• Hydrocarbons– Smaller equipment or large equipment with 

safety precautions

• Hydrofluoro‐olefins (HFOs)– Drop‐in replacements for many gases in testing

• ARB new system web page:– https://www.arb.ca.gov/cc/rmp/rmpnewsystem.htm

Considering a new low‐GWP system? Financial assistance may be available through your utility provider. Please contact us for more information.

49For more information please contact our RMP helpline: 916‐324‐2517 or email [email protected]

Reminders

• Small facilities update registration information by March 1, 2017

• Medium and Large facilities submit Annual Report and pay annual fee by March 1, 2017

• Keep records of leak inspections and refrigerant purchase and use information on‐site.

50

Resources

• Registration Video• https://youtu.be/n‐SZ4IOcO10

• Website• R3 tool website: 

www.arb.ca.gov/rmp‐r3• RMP Program website:

www.arb.ca.gov/rmp• Hotline

(916) 324‐2517• Email

[email protected]• Listserve

Sign up on website51

ARB Contacts

• Erin [email protected]

• Ken [email protected]

52

QUESTIONS?

53