Agilent Technologies Copyright 1999 H7211A+221 v3.0 5-1 Capture Filters, Logging, and Subnets:...

23
Agilent Technologies Copyright 1999 H7211A+221 v3.0 5-1 Capture Filters, Logging, and Subnets: Module Objectives Create capture filters that control whether frames are stored in the Advisor capture buffer or not. Set up to log data for baselining and benchmarking. Implement user defined subnet entries to tell the Adviso how to group addresses on your network.

Transcript of Agilent Technologies Copyright 1999 H7211A+221 v3.0 5-1 Capture Filters, Logging, and Subnets:...

Page 1: Agilent Technologies Copyright 1999 H7211A+221 v3.0 5-1 Capture Filters, Logging, and Subnets: Module Objectives Create capture filters that control whether.

Agilent TechnologiesCopyright 1999H7211A+221 v3.0

5-1

Capture Filters, Logging, and Subnets:Module Objectives

Capture Filters, Logging, and Subnets:Module Objectives

Create capture filters that control whether frames are stored in the Advisor capture buffer or not.

Set up to log data for baselining and benchmarking.

Implement user defined subnet entries to tell the Advisor how to group addresses on your network.

Page 2: Agilent Technologies Copyright 1999 H7211A+221 v3.0 5-1 Capture Filters, Logging, and Subnets: Module Objectives Create capture filters that control whether.

Agilent TechnologiesCopyright 1999H7211A+221 v3.0

5-2

Advisor Block DiagramAdvisor Block Diagram

On

OnRISC

CPU

MAINCPU

COUNTERS

NetworkInterface

CaptureBuffer

SYSTEMRAM

Windows 98 GUI

Specialized Hardware

Line Vital Statistics

PC Display Filters

Max of 26 MB

Capture Filters

Page 3: Agilent Technologies Copyright 1999 H7211A+221 v3.0 5-1 Capture Filters, Logging, and Subnets: Module Objectives Create capture filters that control whether.

Agilent TechnologiesCopyright 1999H7211A+221 v3.0

5-3

ConfigurationConfiguration

(F10)

Page 4: Agilent Technologies Copyright 1999 H7211A+221 v3.0 5-1 Capture Filters, Logging, and Subnets: Module Objectives Create capture filters that control whether.

Agilent TechnologiesCopyright 1999H7211A+221 v3.0

5-4

Capture FiltersCapture Filters

TCP port 80

Server Address

Bad FCS

DNS queries

RISCCPU

MAINCPU

FILTERS

COUNTERS

NetworkInterface

CaptureBuffer

SYSTEMRAM

I/O SUBSYSTEM

Specialized Hardware

Example Filters:

Addresses

Filter criteria must be matched for frames to enter the capture buffer.

Page 5: Agilent Technologies Copyright 1999 H7211A+221 v3.0 5-1 Capture Filters, Logging, and Subnets: Module Objectives Create capture filters that control whether.

Agilent TechnologiesCopyright 1999H7211A+221 v3.0

5-5

Capture Filters TabCapture Filters Tab

Go to the Capture Filters tab to define hardware filters

Page 6: Agilent Technologies Copyright 1999 H7211A+221 v3.0 5-1 Capture Filters, Logging, and Subnets: Module Objectives Create capture filters that control whether.

Agilent TechnologiesCopyright 1999H7211A+221 v3.0

5-6

Capture Filters: AddCapture Filters: Add

Use Capture Filters to control the information going into the Advisor.

Description: Capture only frames to or from me Filter is enabled Uses 2 of 16 resources

Use Add to create a new filter

Graphical display of filter usage

Page 7: Agilent Technologies Copyright 1999 H7211A+221 v3.0 5-1 Capture Filters, Logging, and Subnets: Module Objectives Create capture filters that control whether.

Agilent TechnologiesCopyright 1999H7211A+221 v3.0

5-7

LAN FiltersLAN Filters

Give your filter a name

Optional description

Choose whether to include or exclude frames from the buffer.

You can also start, center or halt capture when the frame is matched

Use LAN Filters tab to define filter

Page 8: Agilent Technologies Copyright 1999 H7211A+221 v3.0 5-1 Capture Filters, Logging, and Subnets: Module Objectives Create capture filters that control whether.

Agilent TechnologiesCopyright 1999H7211A+221 v3.0

5-8

LAN Filters: Creating a Station FilterLAN Filters: Creating a Station Filter

Advanced Options: Can specify encapsulation, Time to Live value, Next protocol code.

Expand Station Filters, Expand Addressing, Enter Addresses, Select boxes to enable.

If desired, use Advanced.

Page 9: Agilent Technologies Copyright 1999 H7211A+221 v3.0 5-1 Capture Filters, Logging, and Subnets: Module Objectives Create capture filters that control whether.

Agilent TechnologiesCopyright 1999H7211A+221 v3.0

5-9

Protocol FiltersProtocol Filters

This filter stores IP and Sun and DECnet frames.

The “+” indicates more ports and protocols are available.

Expand Protocol Filters, Check protocols to include in the filter.

Page 10: Agilent Technologies Copyright 1999 H7211A+221 v3.0 5-1 Capture Filters, Logging, and Subnets: Module Objectives Create capture filters that control whether.

Agilent TechnologiesCopyright 1999H7211A+221 v3.0

5-10

Frame AttributesFrame Attributes

Frame Attributes Tab: Specify frame errors and values for hex bytes.

Or enter text and hex bytes are entered automatically.

Page 11: Agilent Technologies Copyright 1999 H7211A+221 v3.0 5-1 Capture Filters, Logging, and Subnets: Module Objectives Create capture filters that control whether.

Agilent TechnologiesCopyright 1999H7211A+221 v3.0

5-11

Quick Capture FiltersQuick Capture Filters

Copy from Decodes Summary line and Paste into Capture Filters

Copy Paste

Capture Filters

Page 12: Agilent Technologies Copyright 1999 H7211A+221 v3.0 5-1 Capture Filters, Logging, and Subnets: Module Objectives Create capture filters that control whether.

Agilent TechnologiesCopyright 1999H7211A+221 v3.0

5-12

Data Logging Data Logging

Go to the Log Tab to set up data logging.

Page 13: Agilent Technologies Copyright 1999 H7211A+221 v3.0 5-1 Capture Filters, Logging, and Subnets: Module Objectives Create capture filters that control whether.

Agilent TechnologiesCopyright 1999H7211A+221 v3.0

5-13

Logging Parameters Logging Parameters

Connection Statistics and Expert Analyzer log data for each event. The other measurements log data at the specified interval.

Select measurementsto log to file.

Page 14: Agilent Technologies Copyright 1999 H7211A+221 v3.0 5-1 Capture Filters, Logging, and Subnets: Module Objectives Create capture filters that control whether.

Agilent TechnologiesCopyright 1999H7211A+221 v3.0

5-14

More on Log FilesMore on Log Files

When you log Expert, you are also logging Commentator, Connection Stats, and Protocol Vital Stats.

Commentator

Connection Stats

Protocol Vitals

Page 15: Agilent Technologies Copyright 1999 H7211A+221 v3.0 5-1 Capture Filters, Logging, and Subnets: Module Objectives Create capture filters that control whether.

Agilent TechnologiesCopyright 1999H7211A+221 v3.0

5-15

Workspace OptionsWorkspace Options

The last settings of Workspace Options are preserved on exit, and are not changed by merging a new configuration file.

Page 16: Agilent Technologies Copyright 1999 H7211A+221 v3.0 5-1 Capture Filters, Logging, and Subnets: Module Objectives Create capture filters that control whether.

Agilent TechnologiesCopyright 1999H7211A+221 v3.0

5-16

LAN AddressesLAN Addresses

LAN Address Display options do not apply to Decodes. Use the Display Options available in Decodes right mouse click.

Custom subnet definitions

LAN Addresses Default subnet definitions

Advisor IP address forActive Tests

Page 17: Agilent Technologies Copyright 1999 H7211A+221 v3.0 5-1 Capture Filters, Logging, and Subnets: Module Objectives Create capture filters that control whether.

Agilent TechnologiesCopyright 1999H7211A+221 v3.0

5-17

Subnet Mask InfoSubnet Mask Info

10.6.72.102 is an IP address, and 255.255.0.0 is a subnet mask.

IP uses numbers (addresses) to identify networksand to identify individual components of networkscalled hosts (e.g., a workstation or a router).

10.6 NetworkHost: 72.102

Host: 72.103

Host: 72.104

These addresses are divided into 4 octets giving a total of 32 bits to work with.

The 1’s in a subnet mask mark the network ID and the 0’s mark the hosts.

10.6.72.102 = 00001010 . 000000110 . 01001000 . 01100110

255.255.0.0 = 11111111 . 11111111 . 00000000 . 00000000

Given an IP address and a subnet mask, the network number and host number can be determined. This network ID is 10.6, this particular host is 72.102.

Page 18: Agilent Technologies Copyright 1999 H7211A+221 v3.0 5-1 Capture Filters, Logging, and Subnets: Module Objectives Create capture filters that control whether.

Agilent TechnologiesCopyright 1999H7211A+221 v3.0

5-18

Troubleshooting Using SubnetsTroubleshooting Using Subnets

If no User Defined Subnets were entered, this address would be 15.0.0.0 (Class A)and you would not see that 15.70.64.0 and15.6.72.0 were separate subnets.

These nodes are connected to thesubnet 15.6.72.0

2,890 frames: 15.70.64.0 to 15.70.64.0

2,044 frames: 15.70.64.0 to 15.6.72.0

Page 19: Agilent Technologies Copyright 1999 H7211A+221 v3.0 5-1 Capture Filters, Logging, and Subnets: Module Objectives Create capture filters that control whether.

Agilent TechnologiesCopyright 1999H7211A+221 v3.0

5-19

Install ApplicationInstall Application

Install Application

Page 20: Agilent Technologies Copyright 1999 H7211A+221 v3.0 5-1 Capture Filters, Logging, and Subnets: Module Objectives Create capture filters that control whether.

Agilent TechnologiesCopyright 1999H7211A+221 v3.0

5-20

Measurements SettingsMeasurements Settings

Measurements

Page 21: Agilent Technologies Copyright 1999 H7211A+221 v3.0 5-1 Capture Filters, Logging, and Subnets: Module Objectives Create capture filters that control whether.

Agilent TechnologiesCopyright 1999H7211A+221 v3.0

5-21

MAC Node Stats: 50 records of 10-second intervals

Commentator / Connections Stats: 100 connections and events

Decodes: number of frames in capture buffer

Protocol StatsLine Vital Stats 200 records of measurement intervalsProtocol Vital Stats

Windows of Information Windows of Information

Note: when examining a log file, all logged records for all logged measurements are available.

Page 22: Agilent Technologies Copyright 1999 H7211A+221 v3.0 5-1 Capture Filters, Logging, and Subnets: Module Objectives Create capture filters that control whether.

Agilent TechnologiesCopyright 1999H7211A+221 v3.0

5-22

LAB 5.1LAB 5.1

Page 23: Agilent Technologies Copyright 1999 H7211A+221 v3.0 5-1 Capture Filters, Logging, and Subnets: Module Objectives Create capture filters that control whether.

Agilent TechnologiesCopyright 1999H7211A+221 v3.0

5-23

Module 5: ReviewModule 5: Review

You can create capture filters that control whether frames are stored in the Advisor capture buffer or not.

You can log data for baselining and benchmarking.

User defined subnet entries tell the Advisor how to group addresses on your network.