Aexio Xeus Pro 2013 Traffic Measurement Recording Quick Guide
Aexio Xeus Pro 2012 Release Notes
-
Upload
azfahaidar -
Category
Documents
-
view
29 -
download
5
description
Transcript of Aexio Xeus Pro 2012 Release Notes
-
RELEASE NOTES 1
Aexio Xeus Pro 2012 Version 12.4.87 13th Dec 2011
New Features General
Xeus now supports Megamon for Nokia Siemens Network (NSN) New Excel Reporting feature in Drive Test, GPEH and CHR modules. New Report Designer that allow drag-and drop metrics to an Excel template. Enhance Auto-zoom feature for viewing the plots on MapInfo.
Network
Support new dump file version for Huawei Single RAN. Version supported: V900r013 New Import option for user to Create Report and Import Additional Parameters for
Huawei (BSC, WCDMA and RAN), Ericsson BSC and Nokia (BSC & WCDMA) network parser.
Support import and export for Nemo BTS. Support new dump file version for ZTE RNC. Version supported: R3.09 Support Import for Actix CellRef.
Drive Test
Support NEMO 2.10 Support LTE drive test on NEMO 2.10 New bin plots and element view for LTE. Support LTE IE from Agilent
GPEH
Improved speed performance for Geo-Analysis algorithm for faster parsing and better accuracy.
User can filter out call by call end type from imported into the database. This allows the possibility to parse large data set into single GPEH database.
New bin measurement view that displays the information such as radio environment and the event counts in selected bin. This view allows users to perform search for calls in the selected bin.
CHR
New Cell Coverage Analysis for identifying cells with the highest percentage of over coverage calls.
New bin measurement view that displays the information such as radio environment and the event counts in selected bin. This view allows users to perform search for calls in the selected bin.
-
RELEASE NOTES 2
Enhancement Network
A prompt message will notify users when the filename character exceeds the filename character limit.
Drive Test
Enhanced Decoded LTE Layer 3 Message CHR
Enhanced Importing feature that notifies the user if the log file does not contain PCHR or UCHR.
Issue Resolved
The parsing process stops at 45%-48% when 2 or more ROP files are loaded into Xeus. The value for the Call Setup Distance and Call End Distance shown at the Workbench does
not match with the Call Start and Call End location shown on the map. Call Position parcel for Call Start points is not available. Google Earth map zooms to Africa when the user performs Drive Test plots using Line/Polygon. Wrong Message description for non-RANAP in the LogType in disp="RrcRelSigInfo" block. Drive Test Agilent Plots are not removed when the user clicks on Remove plot on map
button. The Neighbor Optimization on CHR will sort the neighbors according to Merit Points even after
the user selects EcNo or Rscp ranking method. The project automatically closes leaving the Legend window open when the user tries to run
Google Earth Web on a newly created project. The GPEH bins are not plotted in Google Earth 6.0.
Aexio Xeus Pro 2012 Version 12.4.20
7th Oct 2011
Enhancements Network
Support MCOM for version 7.3 text files (GSM, WCDMA & LTE) Drive Test
Users can directly parse the Agilent AOD Log file without installing Agilent E6474A Wireless Measurement Software into their system.
GPEH Support GPEH log file for Version W11
-
RELEASE NOTES 3
CHR
New VIP Analysis feature for user to search and bookmark a selected IMSI. Users can also view the Top Subscribers Analysis Chart for the selected IMSI and Subscribers KPI table.
Issue Resolved Unable to import MCOM site data for new projects. The site sector does not load on the Google Earth map. (Desktop -Version 6.1) Unable to load Google Earth Web and Desktop. (Version 6.1) Duplicated value for RSCP_1 and DL_TX_Power_Carrier at the Distribution Chart in GPEH. Inter-changed value for BSIC and ARFCN in Co-Channel Neighbor Analysis. Chart images fail to load completely (partially load) in GPEH and CHR. The removed database still appears at the Project Explorer even after the user closes and
reopens the project.
Aexio Xeus Pro 2012 Version 12.3.30
8th Sept 2011
New Features General
Xeus now supports MapInfo 11 Add Bing Roads and Add OSM Road. Users can now view the neighbor priority number on the map for both Google Earth
and MapInfo. Xeus will automatically synchronize the view on Google Earth Plugin with the view on
MapInfo and Network Explorer when the user clicks on a cell on Google Earth map. Network
Support Ericsson LTE eNodeB KGET Dump Support export for LTE Network data through Xeus Interchange Format (XIF) New IRAT GSM to LTE selection for One Way Neighbor Analysis at Channel and Code
Planning. Drive Test
Support TEMS Investigation 13 log Support new TEMS Investigation FMT for LTE Drive Test. Users can now perform drive
test plotting and view various LTE drive test measurement.
GPEH New VIP Analysis feature for user to search and bookmark a selected IMSI. Users can
also view the Top Subscribers Analysis Chart for the selected IMIS and Subscribers KPI table.
New GPEH binning for Event Count. Users can perform plotting of event count and Statistics by bin.
-
RELEASE NOTES 4
Enhancements General
Enhanced MapInfo settings in Xeus that allows the user to choose between MapInfo 3.0 Compatible and MapInfo Symbols.
Enhanced Network Explorer view that allows the user to sort the neighbor sequence according to priority in the Network Explorer.
GPEH
Improved feature in GPEH Search allowing user to export Call Records or Call Event to Text Tab delimited file.
Improved Neighbor Optimization algorithm feature CHR
Improved feature in GPEH Search allowing user to export Call Records or Call Event to Text Tab delimited file.
Improved Missing neighbor events allowing user to manually defined the hysteresis during parsing.
Improved abnormal Blocked and Dropped Call cause with enhanced cause identification.
Enhanced Xeus Task Manager now allows users to import Huawei CHR log files
Issue Resolved Enhanced Parser for Xeus Interchange Format (XIF) and TEMS Cel File that will notify users if
the value for the cell longitude or latitude is out of range. Fixed IMSI truncated bug for UETR log. Bug fixed for: CellIndex/CellId, Lac, CI, RncId, Cid selection not displayed on Statistic
Plot Add/Edit dialog box. Bug fixed for: Neighbor lines not cleared on Google Map when the user clicks on Removed or
Clear button.
Aexio Xeus Pro 2012 Version 12.2.9
25th July 2011
Issue Resolved Incorrect Latitude & Longitude format when Drive Test TEMS Investigation 12 log file is
exported. An error message will prompt out when the user double click on a message at CHR Message. An error will appear when the user clicks on Add Folder during importing CHR files.
-
RELEASE NOTES 5
When the user clicks on Clear Show Layer button the plots on the map for GPEH and CHR are not removed.
MapInfo 10.5 will crash when the user resizes the MapInfo window. Parsing error occurs when the imported GPEH project is located at a pathname that contains
. symbol.
Aexio Xeus Pro 2012 Version 12.1.66
18th July 2011
New Features/ Enhancements User Interface
New user Interface for Xeus 2012 and Xeus Pro 2012. New Google Earth Web Window that allows the user to hide the Layer control panel. New Icons for user to load Bing Map Aerial or Hybrid layer unto the active map in Xeus. New Icon for user to print the active map in PDF format. New LTE neighbor Icon at Network Explorer.
Network Support new vendor network dump for:-
Alcatel BSC: Version B10 Nortel 3G: Version 5.1 and below Huawei BSC XML Export: Version BSC6000. Huawei RNC EXP CFGMML : Version Below V6900 Nokia WCDMA RAML : Version 4
Support new version of network Dump:-
Huawei RNC EXP CFGMML : Version Below V6900 Huawei Single RAN (GSM & WCDMA) EXP CFGMML: Version V6900 and above Nokia WCDMA RAML : Version 4
Support LTE Network data through Xeus Interchange Format (XIF)
Drive Test
New Enhanced Drive Test Plot Information Element. Support TEMS Investigation 12 log.
GPEH
Improved loading performance for the GPEH Start Page. User Interface: The Tool Box for the required Module will appear visible after the
Module database has been loaded. (E.g. Drive Test will only visible when the database is loaded.)
GPEH Throughput: New page at GPEH Start Page for cell measurement. New GPEH Plot tab for user to perform Geolocation.
-
RELEASE NOTES 6
New distance information elements on Call Summary and Event Summary Worksheet. GPEH binned measurement using the geo-analyzed position in 100m grid. Cell coverage plotting with new cell coverage chart analysis with Ec/No, RSCP and
distance dimension. New Cell Utilization :
Cell Utilization Statistics: Allows user to view the list of key KPI and measurement for cell level, view cell performance and view report summary of the cell utilization (based on per cell).
Cell Utilization Chart view: The chart view is synchronized with the working time on Call Message view.
New Throughput Chart presents the best throughput detected during a call. Hide button at Import GPEH Network Data wizard for user hide the progress bar and
continue working with Xeus while importing GPEH log.
CHR Support Huawei RNC CHR Log file for BSC6800 to BSC6900. Support analysis for Huawei CHR: Block Calls Analysis, Dropped Call Analysis, Cell
Analysis, Neighbor Optimization, Pilot Pollution and Phone Profiling. New bin plots for various CHR plotting type and cell coverage plotting (For only on call
setup location). New CHR Views: CHR Messages & Events, CHR Measurements and CHR Cell Utilization.
Others
A new Cancel button for user to cancel closing Xeus if the user accidentally click close button to close Xeus.
Support Google Earth plugin which enables the user to choose between Google Earth Web or the full Google Earth Desktop.
User can click on the cell on the Google Earth Web and it will automatically synch with other view.
Wizard dialog to guide users through the Google Earth plugin and License Key process. User can plot LTE cell as a separate layer automatically.
Issue Resolved GPEH
User can now import GPEH dump files without Mp0 file by selecting the RNC version at Import Ericsson GPEH/UETR/CTR wizard.
Others A new Cancel button for user to cancel closing Xeus if the user accidentally click close
button to close Xeus. Error when saving a phone model at Phone Type Editor.
-
RELEASE NOTES 7
-
RELEASE NOTES 8
Aexio Xeus 2010 Version 10.3.33
12th April 2011
New Features/ Enhancements GPEH
GPEH state engine supports new W10 dump files
Mapping Support non-WGS84 projection for the Google Earth plot. Xeus will automatically
convert the non-WGS84 projection to WGS84 coordinates before plotting in Google Earth.
Drive Test Enhanced Polygon feature that is able to generate a number of samples within the
polygon for the specified attribute ranges for the selected MS. Others
Xeus will automatically remember the previous file path and display it on the current file path for Open Project.
Issue Resolved Statistics
Synchronization issues: UI issue resolved when synching Xeus with Xeda are listed as below:
1. Error caused by synchronization done without any data. 2. Loading of Statistics drawing on Google Earth. 3. Unable to import or parse site data that does not match. 4. Loading of Xeda ConCheck Summary tab located at Xeda Web Services tab. 5. Error when canceling a synchronization process. 6. Error caused while adjusting the Xeda Web Services scroll bar.
Mapping Bin plot problems cause by Mapinfo 10
Drive Test
Pilot Pollution for drive test analysis was blank.
Network Fixed the neighbor relation for imported or exported TEMS cel file Currently able to filter out Node B sector without AntennaBranch that is not linked to
UtranCell
-
RELEASE NOTES 9
-
RELEASE NOTES 10
Aexio Xeus 2010 Version 10.3.16
28th March 2011
New Features/ Enhancements Drive Test Plots & Events
New Polygon or Line selection for loading plots on Google Earth. New Add Existing Drive Test Database feature: Allows user to directly load the
database without having any drive test performed (this feature is also available for GPEH and Statistics)
Network
Network Properties tab: Antenna Height textbox will not accept any negative value input.
New Notes tab at Network Properties allowing user to insert a note or comment for a cell.
Statistics Create a New KPI Table feature: Others option for entering the delimiters to separate
the field, no longer accepts the input of . and - Others
Xeus will automatically remember the previous file path and display it on the current file path for the new project.
A message box will appear to replace the error message pop out, if the user opens or creates too many KPI reports.
Issue Resolved
Drive Test Unable to synch Statistics Workbook with Network Explorer
Others Unable to import Drive Test Themes that has been exported out Auto-save when Xeus shut down due to no license detected. Create Action Report does not save newly created site.
Aexio Xeus 2010 Version 10.3.13
12th January 2011
New Features/ Enhancements Network
-
RELEASE NOTES 11
New Alarm tab in Xeda Web Services to display the alarm info. New Summary tab in Xeda Web Services to display the 7 days data summary for
ConCheck, Alarm, Mo Changes and Param Changes.