In 2000, MSA set a new standardwith the Advantage 200 LSRespirator, the first half-maskdesigned exclusively for people whowear respirators.
• It weighs less to make it morestable on your face.
• It feels softer to keep youcomfortable.
• It adds new style to safety.
By using a translucent formulationof thermoplastic rubber, theAdvantage 200 LS Respiratorprovides a better-looking, lighter andsofter facepiece that exceeds allprevious levels of comfort. And,because the new facepiece featuresthe same great face seal design asother masks in the Advantage family,wearers of the Advantage 200Respirator do not need to be fit-testedagainbefore theyuse theAdvantage200 LSRespirator.
The Advantage 200 LS Respiratoralso features MSA’s patentedMultiFlex® System – a soft, pliablecombination of rubber and plasticthat provides a virtually customizedfit. In addition, the highly effectiveAnthroCurve™ Sealing Surfaceinstantly conforms to each wearer,equalizing pressure on the face sealarea and eliminating annoyingpressure points.
6
It Fits You In Every WayDespite its groundbreaking design, theAdvantage 200 LS Respirator fits yourbudget as well as it fits your face.
The facepiece has only fourcomponents:
• Facepiece blank • 4-point yoke • Inhalation/exhalation valves• Head harness (choice of single
or 2-piece neck strap).
This cost-effective respirator is easyto maintain, so your inventory – and costs – are minimized.
Advantage 200 LS Respirator
Designed to equalize the pressure around theface-seal area, the revolutionary AnthroCurveSealing Surface ensures optimum comfort for any facial form.
Organic Vapor
ChlorineSulfur D
ioxide
Hydrogen Chloride
Hydrogen Sulfide*
Ammonia
Methylamine
Formaldehyde
Hydrogen Fluoride
Mercury Vapor
Chlorine Dioxide
Filter Type &
Efficiency***
Color Coding
Re-OrderPart Number
815355
815355 with 815394 or 816357
815355 with 815397
815362
815356
815356 with 815394 or 816357
815356 with 815397
815363
815357
815357 with 815394 or 816357
815357 with 815397
815364
815358
815358 with 815394 or 816357
AcroleinAnilineArsineBromineCarbon monoxideDiisocyanatesDimethyl sulfate
815358 with 815397
815365
815359
815359 with 815394 or 816357
815359 with 815397
815366
815641
815361
815361 with 815394 or 816357
815361 with 815397
815368
815369
Advantage RespiratorCartridges
2,32,32,3
2,3,42
2
2
2,42,32,32,3
2,3,42,32,32,3
2,3,42,32,32,3
2,3,42,42,42,42,42,41,4
MSA SeeCartridge NotesDescription OV CL SD CD HC HS* AM MA FM HF MV P100 R95 N95 To RightGMAGMA with N95 PrefilterGMA with R95 PrefilterGMA P100GMBGMB with N95 PrefilterGMB with R95 PrefilterGMB P100GMCGMC with N95 PrefilterGMC with R95 PrefilterGMC P100GMDGMD with N95 PrefilterGMD with R95 PrefilterGMD P100GMEGME with N95 PrefilterGME with R95 PrefilterGME P100GMI P100MersorbMersorb with N95 PrefilterMersorb with R95 PrefilterMersorb P100Low-Profile P100N95 Snap-On Filter and Cover (For Approval InformationSee Chemical Cartridges Above)
R95 Snap-On Filter and Cover (For Approval InformationSee Chemical Cartridges Above)
815394 Pack of 10815357 Pack of 50815392 Reusable Snap-On Cover.
2 in a Package.
815397 Pack of 20815401 Reusable Snap-On Cover.
2 in a Package.
*Escape only. ** Effective against, but not NIOSH-approved for Iodine Vapor.
WARNINGAn appropriate cartridge change-out schedule must be developed by a qualified professional,unless the cartridge/canister utilizes an end-of-service-life indicator.The change-out schedulemust take into account all factors that may influence respiratory protection including specificwork practices and other conditions unique to the worker’s environment. If using againstsubstances having poor warning properties,there is no secondary means of knowing when toreplace the cartridges/canister. In such cases,take appropriate additional precautions to preventoverexposure,which may include a more conservative change-out schedule or using an air-supplied respirator or SCBA.Failure to follow this warning can result in serious personal injuryor death.As a reference,below is a partial list of substances having poor warning properties:
Hydrogen cyanideHydrogen selenideMethanolMethyl bromideMethyl chlorideMethylene chlorideNickel carbonyl
Nitric acidNitro compoundsNitrogen oxidesNitroglycerinNitromethanePhosgenePhosphine
Phosphorus trichlorideStibineSulfur chlorideUrethane or other diisocyanate-containing paintsVinyl chloride
▲!
*** DefinitionsN95-Particulate Filter (95% filter efficiency level) effective againstparticulate aerosols free of oil; time use restrictions may apply.R95-Particulate Filter (95% filter efficiency level) effective against allparticulate aerosols; time use restrictions may apply.P100-Particulate Filter (99.97% filter efficiency level) effective against allparticulate aerosols.
The Advantage line of particulate, chemical andcombination cartridges is NIOSH-approved (to 42 CFR,Part 84) and provides lightweight, low-profile performance.
4
Acid Gases
MSA Ordering and NIOSHApproval Information