Advancing Neuroscience Research SERVICES AVAILABLE Recording and Stimulation Multi-channel data acquisition and neural stimulation for free moving and restrained subjects Micro-manipulation Systems Specially designed micro-positioners for single and multi electrode placement Disposable Electrodes Specially designed acute and chronic electrodes Technical Support On-site and remote support, training, maintenance and more Version 04/2016 Defining Neuroscience Technology

Transcript of Advancing Neuroscience Research - Alpha Omega · 2016. 6. 21. · in two main areas - neuroscience...

Page 1: Advancing Neuroscience Research - Alpha Omega · 2016. 6. 21. · in two main areas - neuroscience research and functional neurosurgery. Over the last two decades we have pioneered

Advancing Neuroscience Research

SERVICES AVAILABLE

Recording and StimulationMulti-channel data acquisition and neural stimulation for free moving and restrained subjects

Micro-manipulation SystemsSpecially designed micro-positioners for single and multi electrode placement

Disposable ElectrodesSpecially designed acute and chronic electrodes

Technical SupportOn-site and remote support, training, maintenance and more

Version 04/2016

Defining Neuroscience Technology

Page 2: Advancing Neuroscience Research - Alpha Omega · 2016. 6. 21. · in two main areas - neuroscience research and functional neurosurgery. Over the last two decades we have pioneered

The brain is the most complex and mysterious human organ. Remarkable doctors and scientists around the world are consistently pioneering new research and methods to understand more about the brain, how it functions, and how to help treat different neurological disorders that affect countless individuals.

Since our inception, Alpha Omega has played an important role in fostering innovation and development in two main areas - neuroscience research and functional neurosurgery. Over the last two decades we have pioneered cutting edge technologies in both fields, receiving international recognition from global experts in each respective area. Today, our equipment can be found in hundreds of hospitals and research institutions, covering 6 continents. Undoubtedly, Alpha Omega’s success is based on the unique and personal relationship we have with our customers. This two-way collaboration allows us to constantly launch new products and versions which are uniquely tailored to our clients’ evolving needs. Therefore, I encourage you to carefully examine our products to understand exactly how they can apply to your particular demands.

Please feel free to contact us at any moment with any of your questions. We are here to serve you, and are glad to welcome you into the Alpha Omega family of satisfied clients!

A Letter from the president

Imad Younispresident

Alpha Omega Neuroscience Suite2

Page 3: Advancing Neuroscience Research - Alpha Omega · 2016. 6. 21. · in two main areas - neuroscience research and functional neurosurgery. Over the last two decades we have pioneered

Mission &Values

Don’t take it from us… here’s what some of our customers have to say

With over 15 years of experience in the laboratory, Alpha Omega’s electrodes for single-unit recording of behaving monkeys offer unparalleled accuracy and robustness – I highly recommend them.

Yasushi Kobayashi PhD

Osaka University Graduate School of Frontier Biosciences

Alpha Omega is by far the most reliable and experienced company in the world in the area of multiple electrode data acquisition - both for laboratory and medical research applications. Their collaborative approach to development and years of experience allow them to consistently stay ahead of the pack

Dr. Hagai Bergman

Chief Investigator, Faculty of Medicine, Hebrew University

I have been a faithful customer of Alpha Omega for more than 10 years and have always been very satisfied by the robustness and reliability of their multiple electrode recording products, especially with respect to signal to noise ratio and filtering. The support provided by the company staff is first rate in terms of speed and availability and they are always ready to test new ideas for new products.

Dr. Thomas Boraud,Director of Research at CNRS, Bordeaux, France

Maintain continued growth on a profitable basis while ensuring company’s integrity

Exceed clients’ expectation with innovative and reliable neural solutions that lead to a better life.

Promote development, leadership and teamwork through empowerment and recognition of the employees

Foster leadership and diversity, and inspire new generations in the community

Alpha Omega Neuroscience Suite 3

Page 4: Advancing Neuroscience Research - Alpha Omega · 2016. 6. 21. · in two main areas - neuroscience research and functional neurosurgery. Over the last two decades we have pioneered

AlphaLab SnR™ Multi-channel system for data acquisition and stimulation

MATLAB Control& Data Access

Micro-manipulation Systems

EPS - Electrode Positioning System

MultiDrive

FlexMT™

Disposable Electrodes

14 Single Electrodes

15 Microelectrode Arrays (MEA)

16 Linear Microelectrode Arrays (LMA)

18 Floating Microelectrode Arrays (FMA)

19 Microwire Arrays (MWA)

19 Injectrodes

05

07

10

11

12

Table ofContents

Alpha Omega Neuroscience Suite4

Page 5: Advancing Neuroscience Research - Alpha Omega · 2016. 6. 21. · in two main areas - neuroscience research and functional neurosurgery. Over the last two decades we have pioneered

AlphaLab SnR™Multi-channel workstation with complete data acquisition and neural stimulation capabilities for both free moving and restrained subjects

The AlphaLab SnR revolutionizes the way neuroscience research is performed in the laboratory, making it the most advanced data acquisition system currently available on the market. The AlphaLab SnR is a comprehensive, fully integrated, system that allows users to record and stimulate from a high number of channels, with unprecedented ease and flexibility.

The system utilizes integrated, advanced stimulation sources to give users the power to deliver complex, unique stimulation patterns to all user-specified channels simultaneously. A high saturation point and advanced hardware components give users the ability to stimulate and record on all channels. Additional tools, such as current return path controls, current monitors, and immediate stimulation logging, make the AlphaLab SnR the most advanced stimulating and recording system available today.

Key qualitiesExpandability high channel. Each system may have between 16 to 128 channels.Data streaming. All data collected by the SnR can be cloned and streamed to multiple computers.Multi-user support. Workload may be optionally divided among multiple computers, allowing multiple users to simultaneously access, analyze, and manipulate the data. Restrained and free moving animals solution.

Connect to variety of electrodes. Impedance check. One-click impedance check.Digitizing headstage. The SnR utilizes a compact, lightweight digitizing headstage that samples each channel at up to 44kHz with a 16 bit A/D resolution. Low noise. less than 5uV @ 500kΩ electrode and less than 3uV @ ground.Differential inputs. The headstage uses differential inputs, which enables acquiring different signal types i.e. EMG, EEG, etc. Powerful DSPs. The SnR is equipped with advanced, powerful DSPs. All processing is done on the SnR itself, not on the PC.Open file format. Files are easily converted to other file formats, including .txt, .mat, .plx, .smr directly imported by common off-line data analysis software.Experimental events log. User-defined events can be created within the software, allowing the researcher to mark the data file with a user-defined variable making offline analysis easier. Controllable digital filtering. The user can select the LP and HP for both spike and LFP recordings.Online sorting. The SnR allows 4 spike templates to be set per channel. 8-point template matching, a SSQ algorithm, and optional window discriminators are utilized to make spike sorting as easy and accurate as possible. Online statistics. Spike raster, firing rate, PSTH and evoked potential

Alpha Omega Neuroscience Suite 5

Page 6: Advancing Neuroscience Research - Alpha Omega · 2016. 6. 21. · in two main areas - neuroscience research and functional neurosurgery. Over the last two decades we have pioneered

Video tracking synchronization. Alpha Omega has partnered with Noldus (Ethovisia*) to provide synchronization between the SnR and Noldus video tracking systems, making the SnR the ideal choice for labs with video tracking needs. * Our software supports Ethovision V9.0 and 11.5

Unique Stimulation CapabilitiesStimulate and record. A high amplifier input range allows non-stimulating channels to record throughout stimulation. All channels can be capable of stimulating and recording.Integrated and scalable stimulation. The SnR may include an embedded stimulation source for each individual channel, giving the researcher the ability to simultaneously stimulate on each channel with unique paradigms.Advanced stimulation control. Modify stimulation parameters with a few clicks, or utilize text based scripting to create complex stimulation waveforms.Conditional stimulation. Stimulation can be trigged by digital inputs, threshold crossings, or template matches.Current return control. Localize and direct injected currents by selecting any number of electrodes as stimulation return channels.Accurate stimulation logging by A stimulation markers logged within 1 sample of the beginning of a stimulation pulse.Current monitor. Online measuring and displaying of injected currentHigh current range. Stimulation sources can output currents. between 2µA-4mA, with pulse width between 40µsec-1msec

Behavior input…

Spikes, LFPs, EMG etc.

FMAs: thetherd =/ wireless*Restrained

Behavior system

Signal Integration Unit

Main Processing Unit

Ethernet Switch

Share Data Display & Control

*Wireless front end is provided by TBSI, Gaithersburg, MD 20879, USA

Store Data

Alpha Omega Neuroscience Suite6

Page 7: Advancing Neuroscience Research - Alpha Omega · 2016. 6. 21. · in two main areas - neuroscience research and functional neurosurgery. Over the last two decades we have pioneered

Technical Specifications For Restrained And Free Moving Animals (FMAs)

Specifications Restrained setupHeadstage

Free Moving setup

Preamp* Follower*Gain 20 10 1Number of channels 16 – 128 (Several 128 channel systems can be cascaded)Dynamic Input Range** ± 62.5mV ± 6.2mV ± 62.5mV

Amplifiers Input Differential Single endedSingle ended1 analog reference channel

Hardware high pass filter (HPF)** 0.075Hz OR 1Hz 0.5Hz DCHardware low pass filter(LPF)** 10KHz 10kHz 10 kHzSampling Rate Maximum 44,000 Samples per Second for each channelA/D Resolution 16 bitBit Resolution 1.9 µV 0.19µV 1.9 µVInput Referred Noise (RMS) 5µV @ 500 KΩ electrodeImpedance check Measure, calculate and report for all electrodesPhysiological Signal Types Spikes, LFP, EEG, EMG and other

Size and weight80mm x 73 mm x 81mm150gr. for 16ch308gr. for 128ch

8ch 13x12mm - 1.5gr.16ch 13x18mm - 2gr.32ch 15x25mm - 3.5gr.

8ch 8x17mm - 2gr.16ch 11.2 x18.4mm - 2gr.32ch 22x36mm - 4gr.

StimulationOptional, supports up to 128 current sources

recording only

Optional stimulation, up to 2 channels out of each 16channels module dedicated current sources.

Commutator - Optional: Manual or motorized mechanical commutator for 16-128ch , supports stimulation

Preamplifier cable length - 60 cm

Signal Integration UnitNo. of channels Up to 128 channels (can be split into two headstages)

Audio Outputs 2 stereo outputsGeneral purpose I/O pack Optional - 16 analog inputs, 8 analog outpts, 4 digital

inputs, 1 digital input port (16 bits), 8 digital outputsStimulation Sources Up to 128 current sourcesStimulation Pulse Width 50 µSec - 1 mSecStimulation Pulse Amplitude Biphasic - 2 µA – 7 mA (up to ±100V)Size 284mm X 258mm X 177mm

Main Processing UnitAudio Outputs 2 stereo outputsAnalog Inputs 16Analog Outputs 8Digital Inputs 4Digital Port (16bit)+ strobe and ready

1 expandable to 9

Digital Outputs 8Size 438mm X 292mm X 177mm (standard 19”)Power 100 V – 240 V, 50Hz - 60HzConnection to PC Standard 1 GB Ethernet

* In addition to the Headstage** When Pre-Amps are used, their spec takes precedence

Headstage

Follower

Alpha Omega Neuroscience Suite 7

Page 8: Advancing Neuroscience Research - Alpha Omega · 2016. 6. 21. · in two main areas - neuroscience research and functional neurosurgery. Over the last two decades we have pioneered

Complete MATLAB Control& Data Access

All data can be cloned and streamed almost instantaneously to multiple computers. This gives users the ability to access data through a MATLAB or C++ toolkit and write custom algorithms. Additionally, commands can be sent back to the SnR from MATLAB or C++ to control the software, adjust parameters, and trigger stimulation, making the system ideal for closed-loop applications.

Data streaming. All data collected by the SnR can be accessed online in MATLAB.

Full system control. From within MATLAB, commands can be sent to adjust almost all system parameters or trigger unique stimulation paradigms.

Closed-loop functionality. Data can be analyzed online, and results can directly trigger digital outputs or stimulation

Easy programming. Specially designed MATLAB toolbox and instructions make accessing data in MATLAB simple and easy.

Endless possibilities. Online access to data means each user can code paradigms specifically for their unique research goals. Examples (shown on right) include online statistics and automatic spike sorting algorithms.

SnR System

SnR Station2SnR Station1

Matlab Station C++ Station,and more...

Alpha Omega Neuroscience Suite8

Page 9: Advancing Neuroscience Research - Alpha Omega · 2016. 6. 21. · in two main areas - neuroscience research and functional neurosurgery. Over the last two decades we have pioneered

Motorized CommutatorMotorized commutator offers a solution for recording neural activities of free moving small animals.

It supports both neural recording and stimulation. The commutator tracks the rotation on the headstage cable and compensate for it, thus eliminating turn-induced torques at the end of the cable connected to the subject.

The commutator is powered by 1500 mAh Li-ion battery. Charged by DC, 6-9 V 500 mA power charger. No PC interface needed for operation.

QualitiesSupports up to 128 recording channelsSupports stimulation (up to 16 stimulation lines)Suitable for small animals with very low torque such as miceSupports Optogenetics or liquid tubesFlexible holdingOptional manual controlLock and keys connectors Dimensions: 13.5*11 cm, 1.2kg5 hours without charging (can work with charger)

Alpha Omega Neuroscience Suite 9

Page 10: Advancing Neuroscience Research - Alpha Omega · 2016. 6. 21. · in two main areas - neuroscience research and functional neurosurgery. Over the last two decades we have pioneered

Compatible with the Flex MT and MultiDrive

Optimize data collection with accurate and independent multi-electrode placement

Improve the quality of neural recordings by recording clean and stable neural signals

Maximize your research by recording crucial data from all electrodes

The Alpha Omega EPS is a state-of-the-art micropositioner designed for the accurate placement of microelectrodes in acute in vivo experiments. The system gives the user maximum flexibility, allowing control of each individual electrode during an experiment, with no noise interference. Moving the electrodes smoothly and independently enables the user to execute research with greater control and precision than ever before.

Key Features and BenefitsMicron precision. The EPS is exceptionally precise. Software controls the electrode movement with micron precision.Electronic control. An easy-to-use software interface ensures accurate, computer controlled electrode placement.Flex MT and MultiDrive compatible. The EPS easily connects to any AlphaOmega microdrive to provide precise control of every electrode.Complete control. Drive all electrodes simultaneously or position a single electrode at a time. Quick and easy setup. The EPS system is easy to setup and operate, reducing the time it takes to perform each experiment.Speed control. Select an entry speed between 5-400 microns/second for each electrode.

Expandability. Choose between 1 to 4 motors per EPS box, and add up to 8 boxes to independently control 1 to 32 electrodes.Remote control. Control the electrode movement from inside the recording room through an easy-to-use joystick interface that allows complete control over each electrode.Reliability. Alpha Omega’s EPS system is durable and reliable, with some customers using the system for over 10 years without the need for service and without the loss of precision.Motor separation. The EPS was specially designed with flexible shafts to separate the motors from the microdrive, significantly reducing the chance of interference that occurs in comparable systems.Independent or group control. All electrodes can be positioned independently as needed, or controlled in user-defined groups for simultaneous control.Less weight. The motor box has been specifically designed to be mounted; electrodes are controlled through flexible shafts to minimize the weight on the chamberLimitless layout options. Flexible shafts allow a single motor box to connect to a variety of micropositioner layouts, making the connection to any Flex MT or MultiDrive easy. Additionally, it’s simple to connect to more than 1 chamber at a time, or to use multiple terminals in one chamber.

EPS - ELECTRODE POSITIONING SYSTEMSpecially designed micropositioner with flexible shafts for multi-electrode placement in restrained subjects

Illustration: User-friendly software

Alpha Omega Neuroscience Suite10

Page 11: Advancing Neuroscience Research - Alpha Omega · 2016. 6. 21. · in two main areas - neuroscience research and functional neurosurgery. Over the last two decades we have pioneered

MultiDrive TerminalPrecision microdrive for electrode manipulation with almost limitless possibilities

Record from any chamber

Choose a custom electrode layout

Reduce setup times

The MultiDrive is an electrode manipulator (microdrive) used to position one or more electrodes during acute, restrained animal experiments. The MultiDrive comes in various models and customizable layout options to meet the different experimental needs of each researcher. The standard MultiDrive gives users independent control of between 4 and 32 electrodes. The dual positioner MultiDrive gives researchers additional control over the trajectory angle, making more targets accessible from a single chamber. Combined with Alpha Omega’s EPS (Electrode Positioning System), the researcher has complete and precise control over all aspects of electrode positioning.

Key Features and BenefitsRecord from any chamber. The MultiDrive easily connects to popular chamber designs. Researchers can also request a custom design, or use a stereotactic mount for small animal experiments.Customizable guides. Design a custom layout for the MultiDrive to optimize electrode spacing and maximize the number of electrodes reaching the desired target.Record from any restrained animal. The MultiDrive can be head mounted onto a chamber, or mounted on a stereotactic frame for smaller animals.Micron precision. The EPS’s flexible shafts connect to the MultiDrive, giving user software controlled, micron precision for all electrodes.Independent electrode control. Each electrode can be controlled independently or together in user-defined groups.No motor noise. The motors are isolated by flexible shafts, reducing mechanical noise and making recording during movement possible.

Control of all axes. The standard MultiDrive gives X and Y control of all electrodes, and micron precision while driving the electrode in the Z plane. Additionally, the dual positioner gives full control over the angle of entry.Tip integrity. Electrodes are back-loaded into individual carriers, preventing damage to the electrode tip.

Microdriving Terminal 32 Channel Positioner

Dual Positioner

Chambers

Product SpecificationsApplicationAcute, Restrained AnimalMounting optionsHead mountable (MultiDrive)Stereotactic frame mountable (miniature MultiDrive)Record from any chamber (custom designs available)Compatible with most Crist chambersNumber of channelsMultiDrive – 4, 8, 16, or 32 channelsDual positioner MultiDrive – 8 or 16 channelsMiniature MultiDrive – 4 or 8 channels

Alpha Omega Neuroscience Suite 11

Page 12: Advancing Neuroscience Research - Alpha Omega · 2016. 6. 21. · in two main areas - neuroscience research and functional neurosurgery. Over the last two decades we have pioneered

Key Features and Benefits Multi-contact probe compatibility. In addition to single electrodes, the Flex MT can drive multi-contact probes, such as the linear microelectrode array or U-probe. Custom adapters are also available for other electrode types.Record from any chamber. The Flex MT easily connects to popular chamber designs. Researchers can also request a custom design, or use a stereotactic mount for small animal experiments.

Quick and easy setup. Towers can easily be positioned and aligned on the ring, and customized grids give researchers an accurate coordinate system for electrode placement.Record from any restrained animal. The Flex MT can be head mounted onto a chamber, or mounted on a stereotactic frame for smaller animals.Modular components. The Flex MT was designed with flexibility in mind. Add or remove electrode drive towers simply and easily. Switch grids between experiments, or swap the chamber adapter with a stereotactic mount for different animal types. Customization is just 1 screwdriver away.

Record from any chamber

Use any electrode or multi-contact electrode

Set-up to record in only a few minutes

The Flex MT is a versatile electrode manipulator (microdrive) used to position one or more electrodes or electrode arrays during acute, restrained animal experiments. Its new and unique design allows for numerous benefits over comparable models and helps improve the efficiency of data collection while reducing setup times for each experiment. A modular, adaptable design means the Flex MT can meet the goals of any researcher. The Flex MT can connect to any chamber, and the Mini Flex MT is optimized for stereotactic frame setups when smaller animals are utilized. Additionally, it is easy to position, align, or swap out electrode drive towers, and each tower can be selected or customized to drive a number of electrode types, including single electrodes, injectrodes, stereotrodes, linear microelectrode arrays, U-probes, or a custom design of the researcher’s choosing. Combined with Alpha Omega’s EPS (Electrode Positioning System), the researcher has complete and precise control over all aspects of electrode positioning.

FlexMT™Flexible microdrive designed with innovation in mind

Alpha Omega Neuroscience Suite12

Page 13: Advancing Neuroscience Research - Alpha Omega · 2016. 6. 21. · in two main areas - neuroscience research and functional neurosurgery. Over the last two decades we have pioneered

Experimental flexibility. Need additional channels, or want to change trajectories? It’s quick and simple to modify the experiment to ensure the target is reached and the desired data is collected.Injection capabilities. Utilize Alpha Omega’s injectrodes to easily add injection capabilities to each tower, making simultaneous fluid delivery and recording simple.Complete chamber access. With the Flex MT, it is easy to position and reposition the electrodes as needed to access any point within the chamber. Micron precision. The EPS’s flexible shafts drive the Flex MT’s towers, giving user software controlled, micron precision for all electrodes.No motor noise. The motors are isolated by flexible shafts, reducing mechanical noise and making recording during movement possible.Tip integrity. Electrodes are back-loaded into individual carriers, preventing damage to the electrode tip.

Drive any number of electrode types. Shown above: injectrode tower (bottom), LMA tower (top right), single electrode tower (top left)Custom designs are available. Shown above: a half-ring Flex MT with 1 single electrode tower and 1 injectrode tower, 1 penetration guide, and a square grid

Product Specifications

Application Acute, Restrained Animal

Mounting options

Head mountable (Flex MT)Sstereotactic frame mountable (Mini Flex MT)Record from any chamber (custom designs available)Compatible with most Crist chambers

Movement range

Coarse – 30mm (customizable)Electronic – 40mmAlignment – 10mm

Tower options

Single Electrode TowerLinear Microelectrode Array TowerU-Probe TowerInjectrode TowerStereotrode TowerCustom Towers available upon request

Grid options

Round (19mm diameter):0.65mm holes every 1mm (gauge 23 guide)0.45mm holes every 0.8mm (gauge 26 guide)

Square (25mm x 25mm):0.65mm holes every 1mm (gauge 23 guide)1.65mm holes every 2mm (gauge 16 guide)2.11mm holes every 2.5mm (gauge 14 guide)3.05mm holes every 3.5mm (gauge 11 guide)

Mini Flex MT:0.65mm holes every 1mm (gauge 23 guide)0.45mm holes every 0.8mm (gauge 26 guide)

Penetration guide options

Beveled or Non-Beveled7 hole spacer (3.05mm)4 hole spacer (2.11mm)4 electrode bundle (1.65mm)

Size Ring diameter – 65mmTower height – 75mm

Weight 55g + 5g for each electrode assembly

Ring options Full ring or half rings are availableCustom diameters available upon request

Alpha Omega Neuroscience Suite 13

Page 14: Advancing Neuroscience Research - Alpha Omega · 2016. 6. 21. · in two main areas - neuroscience research and functional neurosurgery. Over the last two decades we have pioneered

Single ElectrodesA wide offering of single electrodes for everyday use

Product Specifications

Application Acute Recording and Stimulation

Electrode material Tungsten Platinum/Iridium Pure Iridium Stainless Steel

Insulation materialGlassParylene-CParylene-C + Polyimide

Parylene-CParylene-C + Polyimide

Parylene-CParylene-C + Polyimide

Parylene-CParylene-C + Polyimide

Shank diameter

Glass insulated:125, 150, or 200µmParylene-C insulated:75, 125, or 250µm+ Polyimide:75, 125, or 250µm

Parylene-C insulated:75, 125, or 250µm+ Polyimide:75, 125, or 250µm

Parylene-C insulated:100µm+ Polyimide:100µm

Parylene-C insulated:225µm+ Polyimide:225µm

Total diameter

Glass insulated:250, 310, or 380µmParylene-C insulated:80, 130, or 255µm+ Polyimide:125, 215, or 355µm

Parylene-C insulated:80, 130, or 255µm+ Polyimide:125, 215, or 355µm

Parylene-C insulated:105µm+ Polyimide:180µm

Parylene-C insulated:230µm+ Polyimide:355µm

Electrode Length

Glass insulated:30-130mmParylene-C insulated:25-127mm

Parylene-C insulated:25-127mm

Parylene-C insulated:25-76mm

Parylene-C insulated:25-127mm

Impedance

Glass insulated:0.5-2.0 MΩParylene-C insulated:0.1-5.0 MΩ

0.1-5.0 MΩ 0.1-5.0 MΩ 0.1-7.0 MΩ

Tip Shape

Glass insulated:60 or 90˚

Parylene-C insulated:

Standard

Blunt

Heated

Standard

Blunt

Heated

Standard

Blunt

Heated

Standard

Blunt

Heated

Pin Optional Optional Optional Optional

Alpha Omega has a complete line of single electrodes available to meet your research needs. Our electrodes are consistently hailed by researchers as the most robust and durable electrodes available on the market.

Alpha Omega Neuroscience Suite14

Page 15: Advancing Neuroscience Research - Alpha Omega · 2016. 6. 21. · in two main areas - neuroscience research and functional neurosurgery. Over the last two decades we have pioneered

Microelectrode Arrays (MEA)Endless design alternatives for recording and stimulation

The MEA is a high-quality, high-channel count, versatile probe for both acute and chronic recording and stimulation. MEA’s may be designed with between 4 to 128 penetrating microelectrodes per array, and customizable designs are offered to meet each researcher’s precise needs. Each MEA is carefully fabricated to ensure superior signal quality and consistent, reproducible results for each experiment.

Product Specifications

Application Acute and Chronic Recording and Stimulation

Number of channels 4-128 electrodes per array

Electrode material Platinum/Iridium, Tungsten

Insulation materialParylene-C

Polyimide tubing is optional for deep penetrations

Distance between contacts 0.1-1.0mm

Electrode shank diameter 75µm, 125µm, or 250µm

Electrode Impedance 0.01-5.0 MΩ

Electrode Length1.0-40mm

Individual electrode lengths are selectable

Electrode Tip Shape

Standard

Blunt

Heated

Ground Wire Optional

Reference Wire Optional

Connector optionsStandard omnetics

Specify a unique/alternate connector

Alpha Omega Neuroscience Suite 15

Page 16: Advancing Neuroscience Research - Alpha Omega · 2016. 6. 21. · in two main areas - neuroscience research and functional neurosurgery. Over the last two decades we have pioneered

Linear Microelectrode Arrays (LMA)A robust, multi-channel solution for deep brain recordings

Rigid. Sharpened tungsten tip provides stiffness for easy penetration of the dura

Durable. Rugged design for reuse in multiple acute experiments

Customizable Designs. LMA designs are adaptable to a large number of configurations and connector types

Cost Effective. Reasonably priced compared to similar axial arrays on the market

The LMA is a highly customizable, multi-contact probe designed to provide multiple electrodes along one or more shafts. This extremely rugged, versatile, and reusable probe is ideal for both acute and chronic applications.

Alpha Omega Neuroscience Suite16

Page 17: Advancing Neuroscience Research - Alpha Omega · 2016. 6. 21. · in two main areas - neuroscience research and functional neurosurgery. Over the last two decades we have pioneered

Up to 8 shafts may be attached to a single connector Flexible silicone cables allow individual probes to “float” in the brain for chronic applications

Product Specifications

Application Acute and Chronic Recording and Stimulation

Number of channels 4-24 contacts on a single shaft1-8 shafts can be used (up to 192 channels)

Diameter of electrode sites 12.5µm, 25µm, 37.5µm, or 50µm

Distance between contacts 0.075-1.0mm

Number of contacts possible at each depth 2

Electrode Impedance

Typical Impedance at 1KHz:12.5µm – 0.5-0.8 MΩ 25.0µm – 0.3-0.5 MΩ37.5µm – 0.2-0.4 MΩ50.0µm – 0.1-0.3 MΩ

Length25mm maximum for polyimide shaftStainless steel or MRI compatible Microfil tube provides additional length as needed

Polyimide shaft outside diameter

Diameter depends on wire diameter and # of contacts:12.5µm – 198-300µm25.0µm – 198-410µm37.5µm – 218-460µm50.0µm – 218-560µm

Electrode material Platinum/Iridium

Tip length 0.5-2.0mm

Connector options Standard omneticsSpecify a unique/alternate connector

Ground and/or reference wire

Ground and/or reference wire

Alpha Omega Neuroscience Suite 17

Page 18: Advancing Neuroscience Research - Alpha Omega · 2016. 6. 21. · in two main areas - neuroscience research and functional neurosurgery. Over the last two decades we have pioneered

Floating Microelectrode Arrays (FMA)Specially designed for complete flexibility and long-term recording stability

High density FMAs now available!

The FMA offers optimum flexibility and reliability for both acute and chronic applications. These unique arrays allow researchers to specify the length and impedance of each electrode within the same array. The FMA’s reliability, biocompatibility, low profile, and ability to withstand indefinite stimulation make it the perfect choice for long-term chronic applications.

Product Specifications

Application Acute and Chronic Recording and Stimulation

Number of channels 4-36 electrodes per array

Electrode material Platinum/Iridium or Pure Iridium

Insulation material Parylene-C

Distance between contacts 0.4mm0.25mm (for high density FMAs)

Electrode shank diameter Platinum/Iridium – 75µmPure Iridium – 100µm

Electrode Impedance 0.005-2.5 MΩ

Electrode Length 0.5-10mmIndividual electrode lengths are selectable

Electrode Tip Shape Standard

Cable Length 1.5 – 20cm

Array size 1.95 x 2.45 x 0.5mm for 18 channels1.95 x 4 x 0.5mm for 36 channels

Titanium Pedestal Optional

Ground Wire Optional

Reference Wire Optional

Connector options Omnetics A8141, A8784, & A8828

Alpha Omega Neuroscience Suite18

Page 19: Advancing Neuroscience Research - Alpha Omega · 2016. 6. 21. · in two main areas - neuroscience research and functional neurosurgery. Over the last two decades we have pioneered

Microwire Arrays (MWA)A cost-effective solution for high channel counts

InjectrodesA versatile solution for simultaneous recording and fluid injection

The MWA is a highly customizable, cost-effective solution for multi-channel recordings. These extremely versatile arrays are mostly commonly used in chronic recordings, and each array can be assembled with a custom combination of metals and insulating materials. An optional carbowax is also available to help researchers maintaining electrode spacing when deep structures are targeted.

The injectrode has been specially designed to allow researchers to record and inject fluid into the same target site. A single electrode is held within a beveled needle to allow recording as the fluid is delivered. The reusable main assembly is also easily driven by all Alpha Omega microdrives, making adding fluid delivery to experiments simple and cost-effective. Additionally, the beveled needle is offered in a wide range of diameters and lengths, allowing researchers to use almost any electrode on the market.

Product Specifications

Application Chronic Recording and Stimulation

Number of channels 4-64 electrodes per array

Electrode material Platinum/Iridium or Stainless Steel

Insulation material Polyimide or Teflon

Distance between contacts

0.25mm, 0.5mm, 0.75mm, or 1.0mm

Wire diameter 25µm or 50µm

Electrode Impedance

Impedance range depends on wire size and material:25µm Pt/Ir – 0.4-0.8 MΩ50µm Pt/Ir – 0.2-0.4 MΩ25µm SS – 0.6-0.9 MΩ50µm SS – 0.4-0.6 MΩ

Wire Length33mm maximum(10mm beyond carbowax, 23mm within carbowax)

Ground Wire Optional

Reference Wire Optional

Connector options Standard omneticsSpecify a unique/alternate connector

Electrode

O-Ring

Main injectrodeassembly

Electrodeholder/sealer

Alpha Omega Neuroscience Suite 19

Page 20: Advancing Neuroscience Research - Alpha Omega · 2016. 6. 21. · in two main areas - neuroscience research and functional neurosurgery. Over the last two decades we have pioneered

North & South AmericaAlpha Omega Co. USA5755 North Point Pkwy., Unit 229Alpharetta GA 30022, USAToll Free (877) 919-6288Fax (877) [email protected]

[email protected]

EuropeAlpha Omega GmbH Ubstadter Str. 28 76698 Ubstadt-Weiher GermanyToll Free: 00-800-2574-2111Fax: +49 (0) [email protected]

Asia Pacific & Middle EastAlpha Omega EngineeringNazareth Industrial Park BuildingMount Precipice, P.O. Box 2268Nazareth 1612102, IsraelTel 972-4-656-3327Fax [email protected]

In 1993, Alpha Omega was established as a small engineering firm in Nazareth, Israel, by Imad Younis, a specialist in biomedical engineering. From those humble beginnings, our organization has grown into a truly global company, offering a wide range of pioneering products for our clients - along with consistent innovation and uncompromising quality and service. We have done this with the help and close collaboration of world renowned experts and leading research institutions. Almost two decades later, our organization continues to lead the industry with the same mission and determination in mind - improving the quality of patient care in the field of functional neurosurgery, while helping advance neuroscience research.

Today, Alpha Omega has an extensive and established customer base worldwide, and our products can be found in the most advanced hospitals, universities, and research institutions across the globe. Our equipment has been repeatedly tested and used in hundreds of operating rooms and research labs by leading doctors and scientists.

Alpha Omega prides itself not only on innovative technology, but also an extraordinary level of service and personal attention that we dedicate to each and every one of our clients. Our professional sales and support team, located in the United States, Germany, and Israel, along with a select group of international partners, cover the world to offer our clients a helping hand and expert advice whenever and wherever there is a need.

Defining Neuroscience Technology