Advanced Techniques for Computed Tomography (CT)jao/Talks/StudentTalks/openhouse.pdf ·...
Transcript of Advanced Techniques for Computed Tomography (CT)jao/Talks/StudentTalks/openhouse.pdf ·...
Advanced Techniques for Computed Tomography (CT)
Electronic Systems and Signals Research LaboratoryDepartment of Electrical and Systems Engineering
Prof. Joseph A. O’Sullivan and Jasenka [email protected]
http://essrl.wustl.edu/~jao
Supported by a grant from NIH
CollaboratorsFaculty StudentsDonald L. SnyderJoseph A. O’SullivanJeffrey F. Williamson, VCUBruce R. WhitingDavid G. PolitteJames G. BlaineRichard LaforestMark Mintun
Ryan MurphyJasenka BenacShenyu Yan
X-ray CT Imaging
Image Artifacts:Hip Prosthesis
Data from R. Laforest and M. Mintun
CT Imaging in Presence of High Density Attenuators
Brachytherapy applicators: after-loading colpostats for radiation oncology.
Cervical cancer: 50% survival rate.Dose prediction important
Image Artifacts: BrachytherapyGoal Standard
New Alternating Minimization Algorithmfor Transmission Tomography
• Poisson distribution
• Loglikelihood function !lnln)(ln!
)(
kkkNP
ek
kNPk
−−==
== −
λλ
λ λ
)(),(),(exp),():(
):()():(
)(ln)()):(||(
):():(ln)()):(|(
0 yExxyhEyIyg
ygydyg
ydydgdI
ygygydgdl
E x
y
y
βµµ
µµ
µ
µµµ
+⎟⎠
⎞⎜⎝
⎛−=
+−=⋅
−=⋅
∑ ∑
∑
∑
∈
∈
∈
X
Y
Y
• Maximization over m equivalent to minimization of I-divergence
Derivation
⎭⎬⎫
⎩⎨⎧
==
⎟⎠
⎞⎜⎝
⎛−=
+−=
∑
∑ ∑
∑∑
∈ =
∈∈
E
x
I
iii
y Epq
ydEypEyp
ExcxyhEyIEyq
EyqEypEyqEypEypqpI
)(),(:),(
)()(),(exp),(),(
),(),(),(),(ln),()||(minmin
10
L
X
YL
µ
)(~)(ˆ
ln)(
1)(ˆ)(ˆ)(
)()()1(
xbxb
xZxcxc l
i
li
i
li
li −=+
SimulationsMetal rod phantom
Low density rods:AirTeflonWaterAluminum
High density rods:SteelAluminumBrassTeflon
Testing AM Algorithm
David G. PolitteOctober 31, 2002
Mini CT, AM Iteration 0000002
David G. PolitteOctober 31, 2002
Mini CT, AM Iteration 0000005
David G. PolitteOctober 31, 2002
Mini CT, AM Iteration 0000010
David G. PolitteOctober 31, 2002
Mini CT, AM Iteration 0000020
David G. PolitteOctober 31, 2002
Mini CT, AM Iteration 0000050
David G. PolitteOctober 31, 2002
Mini CT, AM Iteration 0000100
David G. PolitteOctober 31, 2002
Mini CT, AM Iteration 0000200
David G. PolitteOctober 31, 2002
Mini CT, AM Iteration 0000500
David G. PolitteOctober 31, 2002
Mini CT, AM Iteration 0001000
David G. PolitteOctober 31, 2002
Mini CT, AM Iteration 0002000
David G. PolitteOctober 31, 2002
Mini CT, AM Iteration 0005000
David G. PolitteOctober 31, 2002
Mini CT, AM Iteration 0010000
David G. PolitteOctober 31, 2002
Mini CT, AM Iteration 0020000
David G. PolitteOctober 31, 2002
Mini CT, AM Iteration 0050000
David G. PolitteOctober 31, 2002
Mini CT, AM Iteration 0100000
David G. PolitteOctober 31, 2002
Mini CT, AM Iteration 0200000
David G. PolitteOctober 31, 2002
Mini CT, AM Iteration 0500000
David G. PolitteOctober 31, 2002
Mini CT, AM Iteration 1000000
PET/CT: Combining Anatomy & Physiology
• ECAT ACCEL: High performance PET scanner
• Siemens Somatom Emotion: High performance, multislicespiral CT
• 70 cm patient port
• Optimized bed design
• Siemens syngo-based computer system
Slides and data from R. Laforest and M. Mintun.
Coregistration & Fusion• Spatial alignment and
visualization of data sets
• Choice of different registration and visualization modes
• Support for CT, MR, NM, and PET DICOM image file format
• Use of CT image to compute PET attenuation map
PETCT-211