Advanced Electrodes

download Advanced Electrodes

of 54

Transcript of Advanced Electrodes

  • 8/14/2019 Advanced Electrodes

    1/54

    Cimatron E 7.1

    Advanced Electrodes Tutorial

  • 8/14/2019 Advanced Electrodes

    2/54

  • 8/14/2019 Advanced Electrodes

    3/54

  • 8/14/2019 Advanced Electrodes

    4/54

  • 8/14/2019 Advanced Electrodes

    5/54

  • 8/14/2019 Advanced Electrodes

    6/54

    Advanced Electrodes

    2 Advanced Electrodes Tutorial Cimatron E 7.1

    Attachment

    Extract

    Click on the Electrode Setup icon.

    Click on the Open File icon and select the Guard.elt part (located in the \\Tutorial Work Files \ Data ToSteel directory) from the Cimatron E Explorer.

    In the Wizard check the Create New folder checkbox and click OK in the Wizard.

  • 8/14/2019 Advanced Electrodes

    7/54

    Cimatron E 7.1 Advanced Electrodes Tutorial 3

    The folder location is chosen through the Browse folder button .

    A new folder has now been created in the Cimatron E Explorer.

    Select Extract Electrode from the Electrode guide on the right hand side of the screen, to create a newelectrode.

    Click on the area shown here.

  • 8/14/2019 Advanced Electrodes

    8/54

    Advanced Electrodes

    4 Advanced Electrodes Tutorial Cimatron E 7.1

    Edit the rectangle so it appears over the part, as follows:

    Click the Middle Mouse Button to attach the faces to the electrode.

    Click the Fit To Selection icon in the Feature Guide.

    Set the parameters as they appear below and press OK in the Feature Guide.

  • 8/14/2019 Advanced Electrodes

    9/54

    Cimatron E 7.1 Advanced Electrodes Tutorial 5

    Electrode TreeThe electrode now appears in the Electrode Tree.

    Activate the electrode by clicking on the Activate Electrode icon and then on the burning area faces (or viceversa).

    OR double click on the electrode in the Electrode Tree.

    Hide the Part.

    The Electrode burning area faces appear below:

  • 8/14/2019 Advanced Electrodes

    10/54

    Advanced Electrodes

    6 Advanced Electrodes Tutorial Cimatron E 7.1

    Blank & Electrode UCS

    Size

    Set the blanks wire bodies properties as shown here.

    Click on the Blank icon in the Electrode Guide.

    Change the Blank Height to 121.5 . (You may need to set the last toggle button to theFree Value: Allowance for example, to enable the Blank Height option.)

    Set the Clearance to 30 .

    Click OK in the Feature Guide to complete the operation .

    Toggle the Free Blank Size option to Use Blank Library and click on Edit Parameters.

    Select the Blank highlighted, from the library:

  • 8/14/2019 Advanced Electrodes

    11/54

    Cimatron E 7.1 Advanced Electrodes Tutorial 7

    Change the Base type to Stepped Base and set the parameters as shown.

    Press on the expansion arrow to the right of the Blank Height option, to show the Clearance distance.

  • 8/14/2019 Advanced Electrodes

    12/54

    Advanced Electrodes

    8 Advanced Electrodes Tutorial Cimatron E 7.1

    Electrode UCS

    Click on the Electrode UCS icon in the Electrode Guide.

    Click on the point marked below:

    Click OK in the Feature Guide.

    The Electrode UCS is used as the reference point for the electrode in drafting and report applications.

  • 8/14/2019 Advanced Electrodes

    13/54

    Cimatron E 7.1 Advanced Electrodes Tutorial 9

    Contour

    Click on the Contour icon in the Electrode Guide.

    Pick the first and last edges, along the burning area faces, as shown below:

    Select OK from the Feature Guide.

  • 8/14/2019 Advanced Electrodes

    14/54

    Advanced Electrodes

    10 Advanced Electrodes Tutorial Cimatron E 7.1

    Extension

    Minimum Distance

    Click on the Extension icon in the Electrode Guide.

    Change the Tangent option to Direction and the Length Option to Minimum Distance .

    Assign a value of 3 for the Minimum Distance.

    Clicking on the arrows in the Minimum Distance dialog will give a preview of the final result.

    Click Apply in the Feature Guide.

  • 8/14/2019 Advanced Electrodes

    15/54

    Cimatron E 7.1 Advanced Electrodes Tutorial 11

    To Blank

    Cimatron E has automatically picked the next contour to extend.

    Change the Minimum Distance option to To Blank .

    Click on the Step icon and set the Simple Step size to 1.5 .

    Press OK in the Feature Guide.

  • 8/14/2019 Advanced Electrodes

    16/54

    Advanced Electrodes

    12 Advanced Electrodes Tutorial Cimatron E 7.1

    Holder

    Click on the Holder icon in the Electrode Guide.

    From the Cimatron E Explorer, select the Holder 3.elt file (located in the \\Tutorial Work Files \ Data ToSteel \ Holders directory).

    The Holder is automatically placed on the Electrode UCS.

    Click OK in the Holder Feature Guide.

  • 8/14/2019 Advanced Electrodes

    17/54

    Cimatron E 7.1 Advanced Electrodes Tutorial 13

    Edit the blank and toggle the Wire Frame option to .

  • 8/14/2019 Advanced Electrodes

    18/54

    Advanced Electrodes

    14 Advanced Electrodes Tutorial Cimatron E 7.1

    Template

    Save TemplateA template of the features used in this electrode will now be created.

    Select Electrode/Save As Template from the main menu bar.

    Save as Tutorial 2 under the \\Cimatron\CimatronE\Data\Templates directory.

  • 8/14/2019 Advanced Electrodes

    19/54

    Cimatron E 7.1 Advanced Electrodes Tutorial 15

    Load Template

    Activate the Assembly.

    OR double click on the Part in the Electrode Tree.

    Show the Guard part.

    Extract the second electrode, using the Fit To Selection option, shown below:

    As with the first electrode, click on Extract Electrode icon from the Electrode guide on the right hand side of thescreen and then click on the part to extract a new electrode.

  • 8/14/2019 Advanced Electrodes

    20/54

    Advanced Electrodes

    16 Advanced Electrodes Tutorial Cimatron E 7.1

    Activate the electrode and create a blank with a Blank Height of 44 and a Base Height of 21 .

    Choose the Stepped Base option, and set the following parameters:

    Press OK in the Feature Guide.

    Create an Electrode UCS in the middle of the blank.

    Click on the Auto Contour icon in the Electrode Guide.

    The following contour is automatically created:

    Now within the Extension step, change the No Template option to Apply Template .

    Click on Change Template and select the file Tutorial 2.etp from the Load Template dialog.

    Move the cursor over the Change Template button and notice the current templates name.

  • 8/14/2019 Advanced Electrodes

    21/54

    Cimatron E 7.1 Advanced Electrodes Tutorial 17

    Click OK in the Feature Guide .

    Click OK when receiving the two messages shown here.

    It can be seen that the holder is not appropriate for the electrode

    Delete the holder, click on the Holder icon and from the Cimatron E Explorer select the Holder 4.elt file(located in the \\Tutorial Work Files \ Data to Steel \ Holders directory).

  • 8/14/2019 Advanced Electrodes

    22/54

    Advanced Electrodes

    18 Advanced Electrodes Tutorial Cimatron E 7.1

    The second electrode has now been created.

  • 8/14/2019 Advanced Electrodes

    23/54

    Cimatron E 7.1 Advanced Electrodes Tutorial 19

    Electrode Options

    Blank

    Hide the first two electrodes and extract the electrode below:

  • 8/14/2019 Advanced Electrodes

    24/54

    Advanced Electrodes

    20 Advanced Electrodes Tutorial Cimatron E 7.1

    Click here for tips on extracting the electrode.

    Select the two faces seen below:

  • 8/14/2019 Advanced Electrodes

    25/54

    Cimatron E 7.1 Advanced Electrodes Tutorial 21

    Select the middle mouse button to attach these faces.

    Verify the 'burn faces selection box' is active and click on the Fit To Selection icon.

    Notice the faces below have also been selected:

    Press SHIFT and drag a rectangle around these faces to de-select the faces.

    Attach the yellow faces to the electrode. via the middle mouse button

  • 8/14/2019 Advanced Electrodes

    26/54

    Advanced Electrodes

    22 Advanced Electrodes Tutorial Cimatron E 7.1

    Click OK in the Feature Guide .

    Create the following blank, using a Stepped Base , with a blank height of 80 and a clearance of 30 .

    Create an Electrode UCS in the middle of the base.

  • 8/14/2019 Advanced Electrodes

    27/54

    Cimatron E 7.1 Advanced Electrodes Tutorial 23

    Extension 1

    As there is more than one contour to be chosen, the standard contour tool will be used to produce the contours.

    Use the Along Open Edges option during contour creation.

    Create a contour and set the parameters of the extension shown as follows:

    Click on the Filler Face icon and press OK in the Feature Guide.

  • 8/14/2019 Advanced Electrodes

    28/54

  • 8/14/2019 Advanced Electrodes

    29/54

    Cimatron E 7.1 Advanced Electrodes Tutorial 25

    Extension 3

    On the middle extension, use the Auto Contour function and create a tangential extension with aMinimum Distance of 1.

    Select Apply and add an extension to the same point shown in the last step.

    Select Apply and extend the middle extension To Blank .

  • 8/14/2019 Advanced Electrodes

    30/54

    Advanced Electrodes

    26 Advanced Electrodes Tutorial Cimatron E 7.1

    Click on the Step icon , and set the following parameters:

    It can be seen the extension does not fit the blank size selected.

    Edit the Blank . Change the Stepped Base option to Base and edit the Blank parameters as follows:

  • 8/14/2019 Advanced Electrodes

    31/54

    Cimatron E 7.1 Advanced Electrodes Tutorial 27

    Finally add the Holder 5.elt file (located in the \\Tutorial Work Files \ Data to Steel \ Holders directory).

  • 8/14/2019 Advanced Electrodes

    32/54

    Advanced Electrodes

    28 Advanced Electrodes Tutorial Cimatron E 7.1

    Add Electrode

    Creation

    Create the following electrode:

    Create the Blank (suitable for Holder 6.elt located in the \\Tutorial Work Files \ Data to Steel \ Holdersdirectory) and Electrode UCS for the electrode.

  • 8/14/2019 Advanced Electrodes

    33/54

    Cimatron E 7.1 Advanced Electrodes Tutorial 29

    Open the Holder 6.elt file and measure the relevant dimensions, in order to determine which blankparameters to set.

    Click an the Auto Contour button and create the first extension, with a filler face, using the followingparameters:

    Create the second extension with a simple step of 1.5 .

  • 8/14/2019 Advanced Electrodes

    34/54

    Advanced Electrodes

    30 Advanced Electrodes Tutorial Cimatron E 7.1

    Right click on the Blank Feature in the Features Tree and select Re-Center.

  • 8/14/2019 Advanced Electrodes

    35/54

    Cimatron E 7.1 Advanced Electrodes Tutorial 31

    Add the Holder 6.elt file.

  • 8/14/2019 Advanced Electrodes

    36/54

    Advanced Electrodes

    32 Advanced Electrodes Tutorial Cimatron E 7.1

    Connect

    Activate the Assembly.

    Right click on the Guard-Electrode-EI-004 electrode in the Electrode Tree, and select Add Location .

    This operation can be carried out by marking the electrode in the Object Tree and selecting Electrode/AddLocation .

    Using the default Place by pick option, and choose a location anywhere outside the part.

    Activate the Guard Part and Copy the Model UCS to the midpoint indicated below:

  • 8/14/2019 Advanced Electrodes

    37/54

    Cimatron E 7.1 Advanced Electrodes Tutorial 33

    Type your drop-down text here.

    Create Main Planes on the new UCS.

    Now activate the electrode copied above and create Main Planes on the Electrode UCS.

  • 8/14/2019 Advanced Electrodes

    38/54

    Advanced Electrodes

    34 Advanced Electrodes Tutorial Cimatron E 7.1

    Activate the Assembly and click on the Connect icon .

    Select the two ZX Planes, select the Align option, and click Apply in the Feature Guide.

    Now select the two faces shown below and click Apply in the Feature Guide:

  • 8/14/2019 Advanced Electrodes

    39/54

  • 8/14/2019 Advanced Electrodes

    40/54

    Advanced Electrodes

    36 Advanced Electrodes Tutorial Cimatron E 7.1

    Trim

    Trim

    Extract an electrode on the extrude circled below:

    Attach the four faces indicated, using the following parameters:

    Select the Trim On option and set the Blank Offset to 4.

  • 8/14/2019 Advanced Electrodes

    41/54

    Cimatron E 7.1 Advanced Electrodes Tutorial 37

    Below is a visual description of the blank offset from the burning area.

    Create the remaining electrode features.

  • 8/14/2019 Advanced Electrodes

    42/54

    Advanced Electrodes

    38 Advanced Electrodes Tutorial Cimatron E 7.1

    EDM Setup

    Standard

    An EDM Setup for a standard machine will now be created.

    Use the same preferences set in the Electrodes tutorial.

    Right click on any electrode in the Electrode Tree and select EDM Setup .

    Set the Rough parameters as follows:

    The wizard opens up according to the branch picked in the Electrode Tree.

    Each branch holds specific Setup information for the EDM process.

  • 8/14/2019 Advanced Electrodes

    43/54

    Cimatron E 7.1 Advanced Electrodes Tutorial 39

    Customize

    Material will now be added to the component.

    Click on the component in the EDM Setup dialog and select the edit icon.

    Type Gold in the edit List dialog and click on Add .

  • 8/14/2019 Advanced Electrodes

    44/54

    Advanced Electrodes

    40 Advanced Electrodes Tutorial Cimatron E 7.1

    In the dialog, select the new material added and move it to the top of the list via the arrow circled below:

    Click OK .

    The new material now appears at the top of the drop down list.

    This method of editing is available in all branches of the EDM Setup.

  • 8/14/2019 Advanced Electrodes

    45/54

    Cimatron E 7.1 Advanced Electrodes Tutorial 41

    The fields and their values are also customizable.

    Click on the Add\Remove Parameters button at the bottom right of the dialog and set the parameters asshown below:

    The fields will be the same for all the electrodes and locations. The values inside these fields may be edited for individual electrodes and locations.

  • 8/14/2019 Advanced Electrodes

    46/54

  • 8/14/2019 Advanced Electrodes

    47/54

    Cimatron E 7.1 Advanced Electrodes Tutorial 43

    AGIEAnother option in the wizard is to select an EDM machine.

    Select the AGIE machine.

    Select Guard-Electrode-EI-004.

    Select the Electrode Family tab.

    Within this tab click on the Get Area button.

  • 8/14/2019 Advanced Electrodes

    48/54

    Advanced Electrodes

    44 Advanced Electrodes Tutorial Cimatron E 7.1

    Click OK upon receiving the following message:

    In the Cimatron environment, select Datum/Plane/Parallel .

  • 8/14/2019 Advanced Electrodes

    49/54

    Cimatron E 7.1 Advanced Electrodes Tutorial 45

    Select this plane and click OK in the Feature Guide .

    As seen in the above example, Cimatron has the means to tailor the interface and output of any EDMrequests according to customer requirements.

  • 8/14/2019 Advanced Electrodes

    50/54

    Advanced Electrodes

    46 Advanced Electrodes Tutorial Cimatron E 7.1

    Report

    Right click on electrode Guard-Electrode-003 in the Electrode Tree and select Report:

    Within the EDM Setup Report dialog the columns can be customized.

    Right click in the dialog and select Report/This Electrode .

    Save the Excel file.

    The report now opens up in Excel format.

  • 8/14/2019 Advanced Electrodes

    51/54

    Cimatron E 7.1 Advanced Electrodes Tutorial 47

    Drafting

    In the Electrode Tree, select the electrode Guard-Electrode-EI-003 :

  • 8/14/2019 Advanced Electrodes

    52/54

    Advanced Electrodes

    48 Advanced Electrodes Tutorial Cimatron E 7.1

    Activate the assembly part and either right click on the electrode within the Electrode Tree or selectElectrode/Create Electrode Drawing .

    The following message now appears:

    By pressing and holding the CTRL key more than one electrode can be picked, the result being a new sheetcreated in the drafting environment, for each electrode.

  • 8/14/2019 Advanced Electrodes

    53/54

    Cimatron E 7.1 Advanced Electrodes Tutorial 49

    Open the Guard-Electrode-EI-003_Drawing.elt drafting document.

    Zoom into view Iso Electrode to observe the distances from the cavity part UCS.

  • 8/14/2019 Advanced Electrodes

    54/54

    Advanced Electrodes

    View the EDM parameters:

    Save your work.