ADDENDUM # 1 · N:\19042 Collingwood Collegiate Institute Life Skills Suite Renovation Addendum No....
Transcript of ADDENDUM # 1 · N:\19042 Collingwood Collegiate Institute Life Skills Suite Renovation Addendum No....
-
ADDENDUM # 1 Solicitation Name: Collingwood Collegiate Institute Life Skills Suite Renovation Solicitation No.: 2020-12702T Date of Issue: Monday July 13, 2020 Closing Date: Monday July 20, 2020 before 1:30 pm Attached is Addendum # 1 issued by MC Architects Inc. for the above project. Karen Charlton Purchasing Department [email protected]
-
PROJECT No. 19042 ADDENDUM No. 1 July 13, 2020
mc | architects Page A1-1
COLLINGWOOD COLLEGIATE INSTITUTE LIFE SKILLS SUITE RENOVATION
6 Cameron Street, Collingwood, Ontario
Tender No. 12702 Simcoe County District School Board
N:\19042 Collingwood Collegiate Institute Life Skills Suite Renovation Addendum No. 1.Docx
A1.1 GENERAL
.1 This Addendum forms part of the Contract Documents and amends the original Specifications and Drawings, dated June 29, 2020, as noted below.
.2 Receipt of this addendum shall be acknowledged in the Bid Form.
.3 Ensure that all parties submitting bids are aware of all items included in this Addendum.
A1.2 PROJECT MANUAL – BIDDING REQUIREMENTS, CONTRACTING REQUIREMENTS, ARCHITECTURAL AND STRUCTURAL SPECIFICATIONS
REF: Instructions to Bidders, Item 1.2 Mandatory Pre-Bid Site Meeting: 1. The following is a list of the General Contract Bidders who attended the Mandatory Pre-Bid
Site Meeting. 1. Anacond Contraction 2. Everstrong Contracting 3. Les Bertram & Sons (1985) Ltd 4. Rutherford Contracting 5. Shertine Construction 6. Silverbirch Contracting 7. W. S. Morgan Construction Ltd
REF: Specification Section 01 00 00 General Requirements, 1.04 Cash Allowances: 1. Article .8, Supply and Installation Cash Allowance.
Revise paragraph .1 to read “Removal/abatement of asbestos containing materials” 2. Article .10 Total Cash Allowance Amount.
Revise total Cash Allowance Amount from $5,000.00 to $15,000.00.
REF: Specification Section 06 41 00 Architectural Woodwork, 1.07 Quality Assurance 1. Article .1 delete this article in its entirety.
REF: Specification Section 08 71 00 Door Hardware
1. The door hardware schedule, as prepared by Upper Canada Specialty Hardware Limited, 6 pages, is hereby issued as part of this addendum and shall become an integral part of the tender documents.
A1.3 ARCHITECTURAL DRAWINGS
.1 No revisions to the architectural drawings as part of this addendum.
A1.4 STRUCTURAL DRAWINGS .1 Structural drawing S1, dated March 30, 1970 for the addition to the school is hereby issued and forms
part of this addendum. This drawing is being issued for reference purposes only to assist bidders with information on the sizes and spacing of the existing structural members requiring spray fireproofing
-
PROJECT No. 19042 ADDENDUM No. 1 July 13, 2020
mc | architects Page A1-2
A1.4 MECHANICAL DRAWINGS .1 No revisions to the mechanical drawings as part of this addendum. A1.5 ELECTRICAL DRAWINGS .1 Refer to the enclosed electrical addendum, 4 pages, dated July 13, 2020, which is hereby issued as
part of this addendum and shall become an integral part of the tender documents.
END OF ADDENDUM No. 1
-
Page 1
Upper Canada Specialty Hardware7100 Warden Ave. Unit 1Markham, Ont., L3R8B5
Collingwood Collegiate Institute Interior Renovatins6 Cameron Street, Collingwood, Ontario
Submittal Date: June 30, 2020
Collingwood Collegiate Institute Interior Renovatins
6 Cameron Street, Collingwood, Ontario
ArchitectMC Architects
201-870 3RD Ave EastOwen Sound, Ontario
CoordinatorMarc Rozon - UCSH Barrie
Tel: 705-733-3507Fax: 705-739-5169
E-Mail: [email protected]
Consultant-----------------
Steve Robinson - UCSH Barrie Tel: 705-733-3507Fax: 705-739-5169
E-Mail: [email protected]
Submittal Date: June 30, 2020
-
Page 2
Upper Canada Specialty Hardware7100 Warden Ave. Unit 1Markham, Ont., L3R8B5
Collingwood Collegiate Institute Interior Renovatins6 Cameron Street, Collingwood, Ontario
Submittal Date: June 30, 2020
Openings Schedule
HardwareGroup Qty
OpeningNumber(s) Location 1 To/ From Location 2 Hand
NominalWidth
NominalHeight
DoorThickness
DoorMat'l
FrameMat'l Label
001 1 001 EXISTING CORRIDOR TO MAIN ROOM 001 LH 1000 2150 45 HM HM 45 MIN
002 1 002 MAIN ROOM 001 TO UNIVERSAL WR 002 RH 1000 2150 45 HM HM
003 1 004 MAIN ROOM FROM CALMING ROOM 004 RHR 1000 2150 45 HM HM
004 1 005 MAIN ROOM 001 FROM BREAKOUT ROOM 005 LHR 1000 2150 45 HM HM
005 1 TC MAIN ROOM 001 FROM TEACHER CLOSET LHRA/RHRA 700, 350 2200 35 WD WD
006 1 SC MAIN ROOM 001 FROM STORAGE CLOSET LHR/RHRA 450, 450 2200 35 WD WD
007 1 MISC-1 - -
-
Page 3
Upper Canada Specialty Hardware7100 Warden Ave. Unit 1Markham, Ont., L3R8B5
Collingwood Collegiate Institute Interior Renovatins6 Cameron Street, Collingwood, Ontario
Submittal Date: June 30, 2020
Hardware Schedule
Heading #001
1 Single door 001, EXISTING CORRIDOR TO MAIN ROOM 001 LH
1000 x 2150 x 45 - HM DR x HM FR - 45 MIN
3 Standard Hinge LH1368CB 127 x 114 C26D C26D1 Lockset 9K 3 (Std.) 7 R 15 D S3 626 6261 Const Core Construction Core White White1 Electric Strike 1006CLB-630-LBM 630-LBM1 Auto Operator 7000 (Pull) c/w On/Off Toggle 628 6282 Push Button CM-46/4 C32D C32D1 Switching Network SA11 Overhead Door Stop 105S C32D (110°) C32D1 Kick Plate GSH 80A C32D (200 x 960) TM C32D
(Confirm Kick Plate Size)1 Weatherstripping W-22-BL x 5300 BL1 Door Sweep W-24S-CA x 1000 CA1 Opening Schematic Opening Schematic - By UC Access
NOTE:- 120V + CONDUIT WITH PULL STRINGS TO ALL ELECTRICAL DEVICES BY ELECTRICAL CONTRACTOR.- LOW VOLTAGE WIRING SUPPLIED & INSTALLED BY AUTO OPERATOR SUPPLIER AS PART OF HARDWARECONTRACT.
-
Page 4
Upper Canada Specialty Hardware7100 Warden Ave. Unit 1Markham, Ont., L3R8B5
Collingwood Collegiate Institute Interior Renovatins6 Cameron Street, Collingwood, Ontario
Submittal Date: June 30, 2020
Heading #002
1 Single door 002, MAIN ROOM 001 TO UNIVERSAL WR 002 RH
1000 x 2150 x 45 - HM DR x HM FR
3 Standard Hinge LH1368CB 127 x 114 C26D C26D2 Lockset 9K 3 (Std.) 7 D 15 D S3 626 6261 Const Core Construction Core White White1 Electric Strike 1006CLB-F-630-LBM (Fail Safe) 630-LBM1 Auto Operator 7000 (Pull) c/w On/Off Toggle 628 6282 Push Button CM-46/4 C32D C32D1 Restroom Cntrol Kit CX-WC13FM (Less Door Contact)1 Emergency Call System CX-WEC101 Power Supply CX-PS13V31 Wall Stop1 GSH 250B C32D C32D1 Kick Plate GSH 80A C32D (200 x 960) TM C32D1 Opening Schematic Opening Schematic - By UC Access
MODE OF OPERATION:1. TO OPEN DOOR ACTIVATE THE DOOR BY THE EXTERIOR BARRIER FREE PUSH PLATE AND DOOR WILL SLOWLYPOWER OPEN. TIME OUT AND SLOWLY CLOSE.2. TO LOCK DOOR FOR PRIVACY ACTIVATE PUSH TO LOCK SWITCH, POWER WILL BE CUT TO EXTERIOR BARRIERPUSH PLATE CREATING PRIVACY.3. ALSO ON ACTIVATION OF THE INTERIOR PUSH TO LOCK SWITCH (#2).4. TO EXIT WASHROOM ACTIVATE INTERIOR BARRIER FREE PUSH PLATE AND THE DOOR WILL SLOWLY OPEN (#3).5. MANUAL NON B/FREE.6. IN NON FIRE RATED APPLICATION, IF THE WASHROOM IS VACANT THE DOOR CAN BE MANUALLY PUSHED OPENAS THE ELECTRIC STRIKE WILL NOT ENGAGED.7. IN A FIRE RATED APPLICATION A KEY WILL BE REQUIRED TO OPERATE THE DOOR MANUALLY (#1). THE KEYWILL UNLOCK THE STOREROOM FUNCTION LOCKSET AS THE ELECTRIC STRIKE MUST BE ENGAGED TO MEETTHE FIRE CODE REQUIREMENT FOR SELF LATCHING.#1 - DOOR CAN ALSO BE OPENED IN A FIRE RATED APPLICATION BY EXTERIOR ACTUATOR IF ROOM IS NOTOCCUPIED.#2 - THE EXTERIOR "AURA" PUSH PLATE WILL CHANGE ILLUMINATION FROM GREEN TO RED ADVISING THAT THEDOOR IS LOCKED AND THE ROOM IS OCCUPIED. AS WELL THE ILLUMINATED PUSH TO LOCK BUTTON. THEINTERIOR PUSH PLATE IS NOT ILLUMINATED.#3 - THE SYSTEM WILL ALSO RESET IF THE DOOR IS OPENED MANUALLY WITH THE DOOR LEVER.
NOTE:- DO NOT USE DOOR CONTACT - UTILIZE LBM IN ELECTRIC STRIKE.- 120V & LOW VOLTAGE WIRING BY ELECTRICAL CONTRACTOR.- OCCUPIED & EMERG KIT TO BE INSTALLED TO CONTROL. THE PRIVACY OF THE OCCUPANT, IN CONJUNCTIONWITH AUTO DOOR OPERATOR AS WELL AS PROVIDED EMERGENCY RESPONSE CAPABILITIES, INCLUDINGALARMS INSIDE & OUTSIDE OF WASHROOM.- ELECTIRC STRIKE TO BE TIED INTO AUTOMATIC DOOR OPERATOR AS WELL AS BOTH INTERIOR ACTUATORS &EXTERIOR ACTUATOR.- DOOR OPERATOR TO BE INSTALLED BY A FACTORY TRAINED INSTALLER AS PART OF THE FINISHING HARDWARECONTRACT. ALL WIRES TO BE RUN BY THE ELECTRICAL CONTRACTOR.
-
Page 5
Upper Canada Specialty Hardware7100 Warden Ave. Unit 1Markham, Ont., L3R8B5
Collingwood Collegiate Institute Interior Renovatins6 Cameron Street, Collingwood, Ontario
Submittal Date: June 30, 2020
Heading #003
1 Single door 004, MAIN ROOM FROM CALMING ROOM 004 RHR
1000 x 2150 x 45 - HM DR x HM FR
3 Standard Hinge LH1368CB 127 x 114 C26D C26D1 Latchset 9K 3 (LC) 0 N 15 D S3 626 6261 Overhead Door Stop 105S C32D (110°) C32D1 Kick Plate GSH 80A C32D (200 x 960) TM C32D
Heading #004
1 Single door 005, MAIN ROOM 001 FROM BREAKOUT ROOM 005 LHR
1000 x 2150 x 45 - HM DR x HM FR
3 Standard Hinge LH1368CB 127 x 114 C26D C26D1 Lockset 9K 3 (Std.) 7 R 15 D S3 626 6261 Const Core Construction Core White White1 Overhead Door Stop 105S C32D (110°) C32D1 Kick Plate GSH 80A C32D (200 x 960) TM C32D
Heading #005
1 Pair of doors TC, MAIN ROOM 001 FROM TEACHER CLOSET LHRA/RHRA
700, 350 x 2200 x 35 - WD DR x WD FR
TEACHER CLOSET
2 Lockset 7KC 3 (Std.) 7 R 15 D STK 626 (35mm Dr) 6262 Const Core Construction Core White White
NOTE:- BALANCE OF HARDWARE BY MILLWORK SUPPLIER.- LOCKSETS TO BE INSTALLED BY MILLOWORK SUPPLIER.
-
Page 6
Upper Canada Specialty Hardware7100 Warden Ave. Unit 1Markham, Ont., L3R8B5
Collingwood Collegiate Institute Interior Renovatins6 Cameron Street, Collingwood, Ontario
Submittal Date: June 30, 2020
Heading #006
1 Pair of doors SC, MAIN ROOM 001 FROM STORAGE CLOSET LHR/RHRA
450, 450 x 2200 x 35 - WD DR x WD FR
1 Lockset 7KC 3 (Std.) 7 R 15 D STK 626 (35mm Dr) 6261 Const Core Construction Core White White
NOTE:- BALANCE OF HARDWARE BY MILLWORK SUPPLIER.- LOCKSETS TO BE INSTALLED BY MILLOWORK SUPPLIER.
Heading #007
1 Elevation MISC-1
__ x __ x __ - - DR x - FR
3 Cut Keys Operating Keys (Best)2 Cut Keys Control Keys (Best)
-
DEI Consulting Engineers | Project No: 20144 Page 1 of 1
July 13, 2020
MC Architects Inc. RE: Collingwood Collegiate Institute 870 3rd Avenue East, Suite 201 Life Skills Room Reno Owen Sound, Ontario N4K 2K5 Job #: 20144 Attn: Mr. Paul Nicholson, Associate, Dip. Arch. DT
ELECTRICAL CHANGE NOTICE
ELECTRICAL
Item 1 1.0 Reference Re-issued Drawing E101
.1 Alternate fixtures added for fixture type L1, L2 and L3 as per re-issued drawing E101. Item 2 2.0 Reference Re-issued Drawing E201
.1 Relocate existing power and data for existing projector as per re-issued drawing E201.
.2 Remove existing power poles in existing computer classroom as per re-issued drawing E201.
.3 Notes 7,8,9 added as follows: 7 INDICATES EXISTING POWER AND DATA FOR EXISTING PROJECTOR TO BE
RELOCATED. REFER TO RENOVATION DRAWING FOR FURTHER INFORMATION, EXTEND CIRCUIT AS REQUIRED.
8 INDICATES EXISTING POWER POLES TO BE REMOVED, LABEL SOURCE BREAKER AS SPARE.
9 REMOVE ALL EXISTING RECESSED RECEPTACLES IN SLAB ON GRADE. COORDINATE QUANTITY ON SITE, LABEL SOURCE BREAKER AS SPARE.
Item 3 3.0 Reference Re-issued Drawing E301
.1 Data and PA sections added to specifications.
Dustin McConkey, Electrical Engineering Technologist 20144 Addendum (E) Jul 13 20.docx dm/md
-
EXIS
TING
CON
TINU
OUS
CURB
CO
UR
TY
AR
DCOURTYARD
N
Project
Sheet Title
Scale
Drawn
Project No.
Checked
Sheet No.
Date Issue
Date Revision
19042
AS NOTED
ISSUED FOR REVIEW2020.06.19
ISSUED FOR TENDER & BUILDING PERMIT2020.06.26
©
55 Northland Road,Waterloo, ON, N2V 1Y8Phone: 519-725-3555Fax: 519-725-2515Website: deiassociates.caProject Number: 20144
JL
CT
mc architectsmcarch.com
Toronto Office:1881 yonge street suite 400 toronto ontario m4s 3c4phone 416 489 4646 fax 416 489 6989
Offices: TORONTO - OWEN SOUND
Owen Sound Office:201-870 3rd ave east owen sound ontario m4s 3c4phone 519 376 8210 fax 519 376 3112
COLLINGWOODCOLLEGIATE INSTITUTELIFE SKILLS SUITE RENOVATION
SIMCOE COUNTY DISTRICT SCHOOL BOARD
Midhurst Ontario
Rev
Of 4
LEGENDS, SCHEDULES,
E1011
& DETAILS
2020.07.13 Re-Issued for AddendumA
-
003
NEWKITCHENETTE
004
NEWCALMING
RM
005
NEWBREAKOUT
RM
001
NEWMAIN ROOM
002
NEWUNIVERSAL
WR
003
NEWKITCHENETTE
004
NEWCALMING
RM
005
NEWBREAKOUT
RM
001
NEWMAIN ROOM
002
NEWUNIVERSAL
WR
Project
Sheet Title
Scale
Drawn
Project No.
Checked
Sheet No.
Date Issue
Date Revision
19042
AS NOTED
ISSUED FOR REVIEW2020.06.19
ISSUED FOR TENDER & BUILDING PERMIT2020.06.26
©
55 Northland Road,Waterloo, ON, N2V 1Y8Phone: 519-725-3555Fax: 519-725-2515Website: deiassociates.caProject Number: 20144
JL
CT
mc architectsmcarch.com
Toronto Office:1881 yonge street suite 400 toronto ontario m4s 3c4phone 416 489 4646 fax 416 489 6989
Offices: TORONTO - OWEN SOUND
Owen Sound Office:201-870 3rd ave east owen sound ontario m4s 3c4phone 519 376 8210 fax 519 376 3112
COLLINGWOODCOLLEGIATE INSTITUTELIFE SKILLS SUITE RENOVATION
SIMCOE COUNTY DISTRICT SCHOOL BOARD
Midhurst Ontario
Rev
Of 4
E2013
GROUND FLOORDEMOLITION / RENOVATION PLANS
2020.07.13 Re-Issued for AddendumA
-
“ ”
“ ”
“ ” “ ” “ ”
– – –
’
’
” ”
–
’
’
Project
Sheet Title
Scale
Drawn
Project No.
Checked
Sheet No.
Date Issue
Date Revision
19042
AS NOTED
ISSUED FOR REVIEW2020.06.19
ISSUED FOR TENDER & BUILDING PERMIT2020.06.26
©
55 Northland Road,Waterloo, ON, N2V 1Y8Phone: 519-725-3555Fax: 519-725-2515Website: deiassociates.caProject Number: 20144
JL
CT
mc architectsmcarch.com
Toronto Office:1881 yonge street suite 400 toronto ontario m4s 3c4phone 416 489 4646 fax 416 489 6989
Offices: TORONTO - OWEN SOUND
Owen Sound Office:201-870 3rd ave east owen sound ontario m4s 3c4phone 519 376 8210 fax 519 376 3112
COLLINGWOODCOLLEGIATE INSTITUTELIFE SKILLS SUITE RENOVATION
SIMCOE COUNTY DISTRICT SCHOOL BOARD
Midhurst Ontario
Rev
Of 4
E3014
SPECIFICATIONS
2020.07.13 Re-Issued for AddendumA
Addendum # 1 - SCDSB Revised Apr 2019ADDENDUM #
Collingwood Collegiate Addendum No. 1Addendum No. 1Collingwood Colleigiate Door HardwareCollingwood S120144 Addendum (E) Jul 13 20