Addc - Jms Rel

14

Click here to load reader

Transcript of Addc - Jms Rel

Page 1: Addc - Jms Rel

ROAD AND SERVICES FOR EAST 48 AND WEST 33 AND OTHER SECTORS IN ABU DHABI CONTRACT NO.674

ADDC -JMS

Sl # B.OQ # Description Location Length, m Width, m Depth, mQuantity

Duct, M

1 1A /1.2 MC 08 - Ch: 0+050.900 11.50 1.90 1.241 27.12

2 1A /1.3 MC 08 - Ch: 0+050.900 6.00 11.50 - - 69.00

3 1A /1.4 Concrete encasement for ducts, concrete volume for conduit and ducts. MC 08 - Ch: 0+050.900 6.00 11.30 1.90 0.400 6.458

4 1A /1.2 MC 08 - Ch: 0+050.900 2.60 0.70 1.241 2.26

5 1A /1.3 MC 08 - Ch: 0+050.900 2.00 2.60 5.20

6 1A /1.4 Concrete encasement for ducts, concrete volume for conduit and ducts. MC 08 - Ch: 0+050.900 2.00 2.40 0.70 0.400 0.521

7 1A /1.2 MC 08 - Ch: 0+083.000 12.30 1.90 1.234 28.84

8 1A /1.3 MC 08 - Ch: 0+083.000 6.00 12.15 72.90

9 1A /1.4 Concrete encasement for ducts, concrete volume for conduit and ducts. MC 08 - Ch: 0+083.000 6.00 12.00 1.90 0.400 6.858

10 1A /1.2 MC 08 - Ch: 0+321.860 12.30 1.90 1.287 30.08

11 1A /1.3 MC 08 - Ch: 0+321.860 6.00 11.84 71.04

12 1A /1.4 Concrete encasement for ducts, concrete volume for conduit and ducts. MC 08 - Ch: 0+321.860 6.00 11.54 1.90 0.400 6.596

13 1A /1.2 MC 02 - Ch: 0+180.230 19.20 1.00 1.325 25.44

14 1A /1.3 MC 02 - Ch: 0+180.230 3.00 18.20 54.60

15 1A /1.4 Concrete encasement for ducts, concrete volume for conduit and ducts. MC 02 - Ch: 0+180.230 3.00 18.00 1.00 0.400 5.504

16 1A /1.2 20.25 1.30 0.400 10.53

17 1A /1.3 6.00 20.25 121.50

No. of Way Excavation,

M3Concrete,

M3Excavate trench in ground of any nature to expose / recover existing cable, backfill the same and reinstate.

Supply and installation of PVC duct of 200mm internal diameter, concrete encased (Concrete measured seperately)

Excavate trench in ground of any nature to expose / recover existing cable, backfill the same and reinstate.

Supply and installation of PVC duct of 200mm internal diameter, concrete encased (Concrete measured seperately)

Excavate trench in ground of any nature to expose / recover existing cable, backfill the same and reinstate.Supply and installation of PVC duct of 200mm internal diameter, concrete encased (Concrete measured seperately)

Excavate trench in ground of any nature to expose / recover existing cable, backfill the same and reinstate.Supply and installation of PVC duct of 200mm internal diameter, concrete encased (Concrete measured seperately)

Excavate trench in ground of any nature to expose / recover existing cable, backfill the same and reinstate.Supply and installation of PVC duct of 200mm internal diameter, concrete encased (Concrete measured seperately)

Excavate trench in ground of any nature to expose / recover existing cable, backfill the same and reinstate.

MC 06 - Ch: 0+287.409 to 0+309.019

Supply and installation of PVC duct of 200mm internal diameter, concrete encased (Concrete measured seperately)

MC 06 - Ch: 0+287.000 to 0+309.019

Page 2: Addc - Jms Rel

18 1A /1.4 Concrete encasement for ducts, concrete volume for conduit and ducts. 6.00 20.25 1.90 0.400 11.574

19 1A /1.2 13.00 1.90 0.400 9.88

20 1A /1.3 4.00 13.00 52.00

21 1A /1.4 Concrete encasement for ducts, concrete volume for conduit and ducts. 4.00 12.80 1.30 0.400 5.048

22 1A /1.2 13.30 1.30 0.400 6.92

23 1A /1.3 4.00 13.30 53.20

24 1A /1.4 Concrete encasement for ducts, concrete volume for conduit and ducts. 4.00 13.10 1.30 0.400 5.166

25 1A /1.2 140.75 1.90 0.400 106.97

26 1A /1.3 6.00 139.25 835.50

27 1A /1.4 Concrete encasement for ducts, concrete volume for conduit and ducts. 6.00 127.53 1.90 0.400 72.888

28 1A /1.4 Concrete encasement for ducts, concrete volume for conduit and ducts. 6.00 11.75 1.30 0.400 3.896

29 1A /1.2 10.85 1.30 0.400 5.64

30 1A /1.3 4.00 10.85 43.40

31 1A /1.4 Concrete encasement for ducts, concrete volume for conduit and ducts. 4.00 10.65 1.30 0.400 4.200

32 1A /1.2 10.62 1.30 0.400 5.52

33 1A /1.3 4.00 10.62 42.48

34 1A /1.4 Concrete encasement for ducts, concrete volume for conduit and ducts. 4.00 10.42 1.30 0.400 4.109

35 1A /1.2 15.00 1.90 0.400 11.40

36 1A /1.3 MC 08 - Ch: 0+051.410 4.00 11.58 46.32

37 1A /1.4 Concrete encasement for ducts, concrete volume for conduit and ducts. MC 08 - Ch: 0+051.410 4.00 11.38 1.30 0.400 4.488

38 1A /1.3 MC 08 - Ch: 0+131.810 4.00 13.52 54.08

39 1A /1.4 Concrete encasement for ducts, concrete volume for conduit and ducts. MC 08 - Ch: 0+131.810 4.00 13.32 1.30 0.400 5.253

MC 06 - Ch: 0+287.000 to 0+309.019

Excavate trench in ground of any nature to expose / recover existing cable, backfill the same and reinstate.

MC 06 - Ch: 0+309.019 to 0+322.651

Supply and installation of PVC duct of 200mm internal diameter, concrete encased (Concrete measured seperately)

MC 06 - Ch: 0+309.019 to 0+322.651

MC 06 - Ch: 0+309.019 to 0+322.651

Excavate trench in ground of any nature to expose / recover existing cable, backfill the same and reinstate.

MC 06 - Ch: 0+339.871 to 0+352.246

Supply and installation of PVC duct of 200mm internal diameter, concrete encased (Concrete measured seperately)

MC 06 - Ch: 0+339.871 to 0+352.246

MC 06 - Ch: 0+339.871 to 0+352.246

Excavate trench in ground of any nature to expose / recover existing cable, backfill the same and reinstate.

MC 06 - Ch: 0+352.246 to 0+492.989

Supply and installation of PVC duct of 200mm internal diameter, concrete encased (Concrete measured seperately)

MC 06 - Ch: 0+352.246 to 0+491.750

MC 06 - Ch: 0+352.246 to 0+480.000

MC 06 - Ch: 0+480.000 to 0+491.750

Excavate trench in ground of any nature to expose / recover existing cable, backfill the same and reinstate.

MC 06 - Ch: 0+492.989 to 0+504.855

Supply and installation of PVC duct of 200mm internal diameter, concrete encased (Concrete measured seperately)

MC 06 - Ch: 0+492.989 to 0+504.855

MC 06 - Ch: 0+492.989 to 0+504.855

Excavate trench in ground of any nature to expose / recover existing cable, backfill the same and reinstate.

MC 06 - Ch: 0+524.756 to 0+537.808

Supply and installation of PVC duct of 200mm internal diameter, concrete encased (Concrete measured seperately)

MC 06 - Ch: 0+524.756 to 0+537.808

MC 06 - Ch: 0+524.756 to 0+537.808

Excavate trench in ground of any nature to expose / recover existing cable, backfill the same and reinstate.

MC 06 - Ch: 0+537.808 to 0+552.717

Supply and installation of PVC duct of 200mm internal diameter, concrete encased (Concrete measured seperately)

Supply and installation of PVC duct of 200mm internal diameter, concrete encased (Concrete measured seperately)

Page 3: Addc - Jms Rel

40 1A /1.3 4.00 18.26 73.04

41 1A /1.4 Concrete encasement for ducts, concrete volume for conduit and ducts. 4.00 18.06 1.30 0.400 7.122

42 1A /1.3 4.00 6.83 27.32

43 1A /1.3 4.00 23.65 94.60

270.60 149.68 1,716.18

Supply and installation of PVC duct of 200mm internal diameter, concrete encased (Concrete measured seperately)

MC 08 - Ch: 0+229.400 to 0+270.160

MC 08 - Ch: 0+229.400 to 0+270.160

Supply and installation of PVC duct of 200mm internal diameter, concrete encased (Concrete measured seperately)

MC 08 - Ch: 0+225.010 to 0+231.840

Supply and installation of PVC duct of 200mm internal diameter, concrete encased (Concrete measured seperately)

MC 08 - Ch: 0+249.170 to 0+272.820

Page 4: Addc - Jms Rel

ROAD AND SERVICES FOR EAST 48 AND WEST 33 AND OTHER SECTORS IN ABU DHABI CONTRACT NO.674

ADDC -JMS

Sl # B.OQ # Description Location Type

1 I/1.16.1 Termination of LV, 4 core 240/185/120mm2 MC 07 ; FP A/3 4C / 240 2.00

4C / 120 2.00

2 II/2.6 Installation of sub - distribution feeder pillar MC 07 ; FP A/3 1.00

3 III/3.3 Recover existing sub-distribution feeder pillar MC 07 ; FP near plot no.64 1.00

4 III/3.3 Recover existing sub-distribution feeder pillar MC 07 ; FP A/1A, FP A/5 2.00

5 III/3.3 Recover existing sub-distribution feeder pillar MC 07 ; FP A/1, FP A/3 2.00

6 III/3.4 Recover existing sub-distribution service cabinets 2.00

7 III/3.4 Recover existing sub-distribution service cabinets 2.00

8 III/3.4 Recover existing sub-distribution service cabinets 1.00

4.00 1.00 5.00 5.00

Quantity, No

(I/1.16.1)Quantity, No (II/2.6)

Quantity, No

(III/3.3)

Quantity, No

(III/3.4)

MC 02 (ST-SWS/2A, MC 06 (ST-SWS/2)

MC 01 (ST-SW/4, MC 08 (ST-SWS/1)

MC 06 (ST-A4; near plot # 21

Page 5: Addc - Jms Rel

DRAWING QUANTITY SUMMARY FOR JOINT MEASUREMENT LV - HV -2

DRG NO : LV/RL/JM-001, LV/RL/JM-002, HV/RL/JM-001, HV/RL/JM-002,

SL NO ITEM NO DESCRIPTION UNIT

LV/R

L/JM

/001

LV/R

L/JM

/002

HV/

RL/J

M/0

01

HV/

RL/J

M/0

02

1 1.12/1a LM 273.00 395.50 668.50

2 1.12.3 LM 286.00 286.00

3 1.12.5 LM 80.00 80.00

4 1.15.1 a Nos 2.00 9.00 11.00

5 1.15.3 Nos 1.00 1.00

6 1.16.1 Nos 1.00 1.00

7 1.16.2 Nos 1.00 1.00

8 1.13 Nos 390.00 156.00 460.00 1,006.00

9 1.14 LM 195.00 78.00 230.00 503.00

CONTRACTOR CONSULTANT CLIENT

WBG HALCROW ADDC

TOTAL QUANTITY

Laying of 11KV 3 Core 240mm² XLPE armoured copper cable

Laying of 4core 240 mm² XLPE Armoured Copper Cable

Laying of LV 4core 120mm² XLPE Armoured Copper Cable

Installation of Straight Joint for 11KV, 3Core 240mm² XLPE armoured copper cable

Installation of LV Cable Joint for 4core 120mm² cable

Termiation of LV 4Core 120mm² XLPE Armoured copper cable to FP-SWS1

Termiation of LV 4Core 70mm² XLPE Armoured copper cable to FP-SWS1

Supply & Install Interlocking Type concrete cable covering slabs for LV Cable/HV Cable

Supply & Install Warning Tape (30cm width, 150 microm thick) in the trench for LV Cables

Page 6: Addc - Jms Rel

ABU DHABI DISTRIBUTION COMPANY, P O BOXNO -219, ABU DHABI

PROJECT : INTERNAL ROADS AND INFRASTRUCTURE FOR SECTORS EAST 48 AND WEST 33

DRAWING QUANTITY SUMMARY FOR JOINT MEASUREMENT LV - HV -1

MAIN CONTRACTOR - WBG

ELECTRICAL CONTRACTOR - SPACEAGE

SL NO ITEM NO DESCRIPTION UNIT QUANTITY REMARKS

1 1A /1.2 Excavate trench to expose / recover, backfill and reinstate. M3 270.60

2 1A /1.3 Supply and installation of PVC duct of 200mm diameter M 1,716.18

3 1A /1.4 Concrete encasement for ducts M3 149.68

4 I/1.16.1 Termination of LV, 4 core 240/185/120mm2 NO 4.00

5 II/2.6 Installation of sub - distribution feeder pillar NO 1.00

6 III/3.3 Recover existing sub-distribution feeder pillar NO 5.00

7 III/3.4 Recover existing sub-distribution service cabinets NO 5.00

CONTRACTOR CONSULTANT CLIENT

WBG HALCROW ADDC

Page 7: Addc - Jms Rel

DRAWING QUANTITY SUMMARY FOR JOINT MEASUREMENT LV - HV -1

DRG NO : JMS/674/EP/01, /ED/01, /RL-RM/01

PROJECT : INTERNAL ROADS AND INFRASTRUCTURE FOR SECTORS EAST 48 AND WEST 33

SL NO DESCRIPTION UNITQUANTITY

PREVIOUS CURRENT TO DATE

1 1A /1.2 M3 0.00 270.60 270.60 40.00 10,824.00

2 1A /1.3 M 0.00 1,716.18 1,716.18 150.00 257,427.00

3 1A /1.4 Concrete encasement for ducts M3 0.00 149.68 149.68 400.00 59,872.00

4 I/1.16.1 Termination of LV, 4 core 240/185/120mm2 NO 0.00 4.00 4.00 600.00 2,400.00

5 II/2.6 Installation of sub - distribution feeder pillar NO 0.00 1.00 1.00 2,500.00 2,500.00

6 III/3.3 Recover existing sub-distribution feeder pillar NO 0.00 5.00 5.00 2,000.00 10,000.00

7 III/3.4 NO 0.00 5.00 5.00 2,000.00 10,000.00

TOTAL 353,023.00

CONTRACTOR CONSULTANT CLIENT

WBG HALCROW ADDC

ITEM NO

UNIT PRICE (DHS)

AMOUNT (DHS)

Excavate trench to expose / recover, backfill and reinstate.

Supply and installation of PVC duct of 200mm diameter

Recover existing sub-distribution service cabinets

Page 8: Addc - Jms Rel

CONTRACT NO - 674

ROAD AND SERVICES FOR EAST 48 AND WEST 33 AND OTHER SECTORS IN ABU DHABI CONTRACT NO.674

Sl # MATERIAL

UN

ITS

Qua

ntity

, No

(III/

3.4)

TOTA

L M

ATER

IAL

ISSU

ED B

Y AD

DC

STO

RE (F

REE

ISSU

E)

TOTA

L M

ATER

IAL

ISSU

ED

FRO

M O

THER

SO

URC

ES

TOTA

L M

ATER

IAL

SUPP

LIED

BY

CO

NTR

ACTO

R (N

EW

MAT

ERIA

L)

TOTA

L M

ATER

IAL

RECO

VERE

D

TOTA

L M

ATER

IAL

RECE

IVED

(T

1 =

A+B+

C+D

+E)