ACUSON P10 Ultrasound System - Siemens Healthcare MR

8
ACUSON P10 Ultrasound System Environmental Product Declaration www.siemens.com/healthcare

Transcript of ACUSON P10 Ultrasound System - Siemens Healthcare MR

Page 1: ACUSON P10 Ultrasound System - Siemens Healthcare MR

ACUSON P10 Ultrasound System

Environmental Product Declaration

www.siemens.com/healthcare

Page 2: ACUSON P10 Ultrasound System - Siemens Healthcare MR

Progress that is ImpressiveEcological Advantages of ACUSON P10™ Ultrasound System

• Uses less energy than a full-sized ultrasound system

• Uses a removable, rechargeable lithium ion battery

• Small mass and few components

• Modular product architecture allows for easy dismantling

• No mercury in keypad backlighting

• Suppliers are integrated into the product-related

environmental protection system

• Substances contained in the products and their

packaging are documented

• Product take-back program

• Over 95% of the system can be recycled at end-of-life

• Disassembly instructions for high-quality recycling

are available

2

Energy Efficiency

Energy efficiency has been designed into the

ACUSON P10 system with instant power-up,

battery saving power management and

fast power-down. The ACUSON P10 system

operates on a rechargeable lithium ion battery.

Page 3: ACUSON P10 Ultrasound System - Siemens Healthcare MR

Revolutionize the Way You Work

The ACUSON P10 system is the first pocket ultrasound imaging device providing physicians and clinical personnel with earlier, faster and more accurate clinical assessments at the point-of-care.

Benefits

• Cost-effective, real-time imaging that supports your financial strategies while improving quality of care

• Ultra-portable means you are never without information

• Improves diagnostic confidence through visual information because seeing is believing

• Instant power-up for quick decisions because time to information can be the difference between life and death

Cardiology

The ACUSON P10 system enables you to visualize basic anatomy, function and effusion as part of an initial patient assessment, routine follow-up or in pre/post procedures care in the ICU/CCU.

Emergency Medicine

Not since the introduction of the stethoscope has one tool promised to do more to enhance emergency medical screening and triage assessments. The ACUSON P10 system allows clinicians and EMTs to make faster and more accurate decisions by providing visual information when and where it’s needed.

Obstetrics

The ACUSON P10 system gives physicians and midwives a quick and comprehensive overview on fetal positioning, anatomy, heart beat, fluid levels and placenta location during labor or routine office visits.

Reduced Environmental Footprint

With less mass, fewer components, better

energy efficiency and reduced shipping

weight as compared to a full-size ultrasound

system, the ACUSON P10 system proves it

is possible to have powerful performance

without a large environmental footprint.

3

Page 4: ACUSON P10 Ultrasound System - Siemens Healthcare MR

Environmental Management System

Our environmental, health and safety management system conforms to a variety of recognized standards, including ISO 14001 (Environmental Management Systems), OHSAS 18001 (“Occupational Health & Safety Management Systems Specification), BS 8800 (British Standard for Occupational Health and Safety Systems), and ANSI Z.10 (Standard for Occupational Health and Safety Management Systems). Further information about our environmental, health and safety management system is available at www.siemens.com/medical-ehs.

Declaration of Conformity and Siemens AG Medical Solutions Registration

Our environmental, health and safety management

system conforms to a variety of recognized standards,

including ISO 14001 (Environmental Management

System), OHSAS 18001 (Occupational Health & Safety

Management Systems Specification), BS 8800 (British

Standard for Occupational Health & Safety Systems)

and ANSI Z.10 (Standard for Occupational Health &

Safety Management Systems).

Further information about our environmental,

health and safety management system is available

at www.siemens.com/healthcare-ehs.

Siemens considers environmental aspects in all phases

of the product lifecycle, including material supply,

production/delivery, use/maintenance and end-of-life.

Our product design procedure fulfills the requirements

of IEC60601-1-9:2007 “Environmental product design

for medical electrical equipment”.

This standard supports the effort to improve the

environmental performance of our products.

Environmental Product Design

Material supply From natural resources to delivery of semi-finished products

Production/delivery From production of components to operation startup by the customer

Use/maintenance Includes daily use by our customers as well as maintenance

End-of-life From disassembly at the customer site, through material and energy recycling

www.siemens.com/medical

Declaration of Conformity& Siemens AG MedicalSolutions RegistrationTo the Siemens Medical Solutions Environmental,Health and Safety Management System (EH&S MS)

Siemens AG Medical Solutions declares that thelisted medical business units are in conformancewith requirements of the Siemens Medical Solutions(MED) environmental, health and safety manage-ment system (EH&S MS), and issues this internalregistration certificate. The MED EH&S managementsystem is consistent with ISO 14001:2004, OHSAS 18001, BS 8800 and ANSI Z. 10. Certificate isValid Until August 1, 2009.

Siemens Medical Solutions Business Units:Ultrasound Division

Address:All Ultrasound Division manufacturing and PLM loca-tions in the United States and the Republic of Korea.

Medical Device Products and Services:Development, Production and Distribution ofDiagnostic Ultrasound Imaging Equipment

Siemens AG Medical Solutions EHS (Internal Registrar) Signature

Name/Signature:Vice President Quality and Technology Head of Environmental, Health and SafetySiemens Medical Solutions Siemens Medical Solutions

Identification of Product Ingredients

The ACUSON P10 system is mainly built

out of metals and plastics. This ensures

a high degree of recyclability.

Total weight: approx. 1.6 lbs (0.725 kg)

EMAS: validated information – Environmental declaration 20084 5

4

SOMATOM Definition AS is mainly buildout of metals. This ensures a high degreeof recyclability.

Total weight: approx. 3500 kg

Identification of Product Ingredients

EMAS: validated information – Environmental declaration 2008

Material supply:From natural resources to deliveryof semi-finished products

Production/delivery:From production of components tooperation startup by the customer

Use/maintenance:Includes daily use by our customersas well as maintenance

End of life:From disassembly at the customerthrough material and energyrecycling

Our environmental, health and safety management sys-tem conforms to ISO 14001 and helps us put our policy into practice. Our German manufacturing facilities were among the first to be validated to EMAS (Environ-mental Management and Audit Scheme).

You find further information about our environmental, health and safety management system at www.siemens.com/healthcare-ehs.

Environmental Management System

Environmental Product Design

Siemens considers environmental aspects in all phases of the product life cycle, including material supply,production/delivery, use/maintenance and end of life.

Our product design procedure fulfills the requirements of IEC60601-1-9:2007 “Environmental product design for medical electrical equipment”.

This standard supports the effort to improve the envi-ronmental performance of our products.

Ferrous alloys, steels 64 % Nonferrous metals and alloys 22 % Precious metals 0,012 % Other metals and semimetals 0,24 % Inorganic materials, ceramics 2,2 % Plastics 9,8 % Other Materials 0,43 % Organic substances 0,63 % Critical substances 0,46 %

Page 5: ACUSON P10 Ultrasound System - Siemens Healthcare MR

Cumulative Energy Demand

Energy consumption is the most important

environmental characteristic of medical devices.

This is why we use cumulative energy demand to

assess environmental performance. Cumulative

energy demand is the total primary energy*

consumed across the product’s entire lifecycle – the

energy necessary to produce, use and dispose of

a device – including all transportation. We design

our products with the goal of reducing cumulative

energy demand.

* Primary energy is the energy contained in natural resources prior to undergoing any human made conversion (e.g. oil, solar)

Packaging

The ACUSON P10 system’s packaging materials

consist of almost entirely of cardboard, foam

and other plastics, all of which can be recycled.

Total weight of packaging: approx. 2.6 lbs (1.2 kg)

Product Take Back

Our product take-back program ensures we address

the environmental aspects of our products – even at

the end-of-life. We take back products, packaging

and batteries as required by laws and regulations.

As part of this program, we refurbish systems and

reuse components whenever possible through our

Refurbished System business. By having thorough

knowledge of the materials comprising our products,

we can design products to maximize reuse, recycling

and energy recovery.

Nearly all the materials in the ACUSON P10 system

have further use at the end of the product’s useful

life: 82% can be recycled and 18% can be used

as fuel.

Siemens provides disassembly instructions to

treatment facilities for the safe and proper

removal and recycling of electronic components

in this product.

4 5

Primary Energy

Composition of Packaging

Product End-of-Life Options

Page 6: ACUSON P10 Ultrasound System - Siemens Healthcare MR

6 7

Operating Data

Allowed relative humidity1 30–80%

Noise level <50 dB

Energy Consumption

• during ramp up2 ≤0.03 kW

• basic load3 ≤0.03 kW

• full load4 ≤0.03 kW

• energy saving mode5 ≤0.00 kW

Power-on time2 80 seconds

Power-off time6 1 second1 Within examination room2 From off-mode to operating state 3 Device is in operation but no patient examination is taking place4 Average value for energy consumption during examination of patients5 Device is in energy saving mode6 From operating state to off-mode

Technical Specifications

Interface for heat recovery No

Possible type of cooling Air-cooling

Complete switch-off is possible Yes

Page 7: ACUSON P10 Ultrasound System - Siemens Healthcare MR

6 7

Replacement Parts and Consumable

Item Lifecycle

Laptop Battery (Lithium Ion) Varies with usage

Disposal / Substance Information

End-of-life concept Yes

Product recycling available Yes

Packaging recycling available Yes

Cleaning

Incompatible cleaning processes

• For product

• For particular components

Do not use spray cleaner.

Do not pour any fluid onto the ultrasound system. Avoid use of aerosol spray cleaners on monitor screen.

Ensure that cleaning solution does not seep into the control panel, keyboard, or any other openings.

Incompatible cleaning substance

• For product

• For particular components

Do not use chlorinated or aromatic solvents, acidic or basic solutions, isopropyl alcohol or strong cleaners such as ammoniated products.

Size of the surface to be cleaned 0.15 m2

Additional Ecologically Relevant Information

The “Instructions for Use” contain information about:

• Recommendations for saving energy

• Recommendations for efficient cleaning

• Recommendations for appropriate use of consumables

• Product recycling availability

• Packaging recycling availability

Yes

Yes

Yes

Yes

Yes

“Disassembly Instructions” are available Yes

Page 8: ACUSON P10 Ultrasound System - Siemens Healthcare MR

ACUSON and P10 are trademarks of Siemens Medical Solutions USA, Inc.

WS 0509 I © 05.2009, Siemens Medical Solutions USA, Inc.

Local Contact InformationSiemens Medical Solutions USA, Inc.51 Valley Stream ParkwayMalvern, PA 19355-1406 USATelephone: +1-888-826-9702www.usa.siemens.com/healthcare

Europe: + 49 9131 84-0Asia Pacific: + 65 6490 6000

Global Business Unit AddressSiemens Medical Solutions USA, Inc.Ultrasound1230 Shorebird WayMountain View, CA 94043 USATelephone: +1-888-826-9702www.siemens.com/healthcare

Legal ManufacturerSiemens Medical Solutions USA, Inc.Ultrasound1230 Shorebird WayMountain View, CA 94043 USATelephone: +1-888-826-9702www.siemens.com/healthcare

Global Siemens HeadquartersSiemens AGWittelsbacherplatz 280333 MunichGermany

Global SiemensHealthcare HeadquartersGlobal Siemens AGHealthcare SectorHenkestrasse 12791052 ErlangenGermanyTelephone: + 49 9131 84-0www.siemens.com/healthcare