ACUPRO Version 4 slide show - TFAcoustics · 5 ACUPRO 5 Standards 1. ISO 10534-2,...
Transcript of ACUPRO Version 4 slide show - TFAcoustics · 5 ACUPRO 5 Standards 1. ISO 10534-2,...
4
ACUPRO 5
Research Foundation
1. Seybert, A.F. and Ross, D.F., Experimental Determination of AcousticProperties Using a Two-microphone Random Excitation Technique, J.Acoust. Soc. Am., 61, 1362-1370 (1977)
2. Chung, J.Y. and Blaser, D.A., Transfer Function Method of MeasuringIn-duct Acoustic Properties, II: Experiment, J. Acoust. Soc. Am, 68,914-921 (1980)
3. Seybert, A.F., Two-sensor Methods for the Measurement of SoundIntensity and Acoustic Properties in Ducts, J. Acoust. Soc. Am, 83,2233-2239 (1988)
4. Tao, Z. and Seybert, A. F., A Review of Current Techniques forMeasuring Muffler Transmission Loss, Proceedings, SAE Noise andVibration Conference, Traverse City, paper 2003-01-1653 (2003)
5
ACUPRO 5
Standards
1. ISO 10534-2, Acoustics-Determination of sound absorption coefficientand impedance in impedance tubes - Part 2: Transfer-function method
2. ASTM E1050-98, Standard Test Method for Impedance andAbsorption of Acoustical Material Using a Tube, Two Microphones anda Digital Frequency Analysis System
6
ACUPRO 5
ACUPRO Hardware
• Exceeds ISO and ASTM design requirements• Thick-walled, highly damped materials reduce vibration• Precision machining insures plane wave sound field• Microphone mounting is secure and sealed• High output JBL compression driver
JBL 2426JDriver
7
ACUPRO 5
Specifications
• Frequency range: 50 Hz – 5700 Hz• Maximum SPL in tube: ~ 150 dB• Ambient noise in tube: < 30 dBA• Microphones: ¼ and/or ½ inch• Tube inside diameter: 34.9 mm• Tube outside diameter: 41.3 mm• Maximum length of sample: 14 cm• Overall length: 1.20 m (with sample
holder)• Total mass: 10.5 kg
8
ACUPRO 5
Software Features - General
• Runs under Windows 10• Reads text files from any analyzer• Graphics visualization of all results• Log window tracks history• Hard copy of graphical results• Soft copy of all data in text files• Access to ACUPRO manual
9
ACUPRO 5
Sound Absorption Measurement
Sample holder with rigid piston
10
ACUPRO 5
Software Features – Absorption Measurement
• Corrects microphone amplitude and phase• Corrects for latent tube absorption• Determines the following properties
Sound absorption coefficientComplex sound reflection coefficientComplex surface impedanceComplex surface admittance
• Outputs data for flow resistivity determination
11
ACUPRO Version 5
Material Characterization Module
Correction for microphone amplitude and phase response
Graphical display windows
12
ACUPRO 5
Example - Absorption Measurement
0.0
0.2
0.4
0.6
0.8
1.0
0 1000 2000 3000 4000 5000Frequency (Hz)
Abs
orpt
ion
Coe
ffici
ent
Foam with coverFoam without cover
13
Measurement of Transmission LossACUPRO 5
Optional TL tube
14
ACUPRO 5
Software Features – TL Measurement
• Corrects microphone amplitude and phase• Determines transmission loss (TL) of
• Barrier materials• Mufflers and silencers
• Other material properties determinedComplex wave numberComplex material densityComplex sound speed in materialComplex characteristic impedance
15
ACUPRO 5
Transmission Loss Module
Files for TL calculation
Properties determined
16
ACUPRO 5
0
5
10
15
20
25
30
35
40
45
50
0 1000 2000 3000 4000 5000 6000Frequency (Hz)
TL (d
B)
Measured TL of Barrier Material
17
ACUPRO 5
0
5
10
15
20
25
30
0 500 1000 1500 2000 2500 3000Frequency (Hz)
TL (d
B)
Measured TL of an Expansion Chamber Muffler
20 cm