Acoustics Research Institute S_TOOLS -STx Supplement Speech Formant Tracking and Fundamental...

9
Acoustics Research Institute S_TOOLS -STx Supplement Speech Formant Tracking and Fundamental Frequency Extraction Default Parameter Setting

Transcript of Acoustics Research Institute S_TOOLS -STx Supplement Speech Formant Tracking and Fundamental...

Page 1: Acoustics Research Institute S_TOOLS -STx Supplement Speech Formant Tracking and Fundamental Frequency Extraction Default Parameter Setting.

Acoustics Research Institute

S_TOOLS -STx Supplement

Speech Formant Trackingand Fundamental Frequency

Extraction Default Parameter Setting

Page 2: Acoustics Research Institute S_TOOLS -STx Supplement Speech Formant Tracking and Fundamental Frequency Extraction Default Parameter Setting.

2

AcousticsResearchInstitute

ARI

Speech Spectrogram and Parameter Extraction Overview

Page 3: Acoustics Research Institute S_TOOLS -STx Supplement Speech Formant Tracking and Fundamental Frequency Extraction Default Parameter Setting.

3

AcousticsResearchInstitute

ARI

Speech Spectrogram & Formant Analysis

Setup of Profile „FFT_Speech_FOR“

Specify Mode ON/OFF:• Spectrogram• Fundamental Frequency

Analysis(autocorrelation method)

• Waveform Plot• Formants, show formants

on spectrogram

Page 4: Acoustics Research Institute S_TOOLS -STx Supplement Speech Formant Tracking and Fundamental Frequency Extraction Default Parameter Setting.

4

AcousticsResearchInstitute

ARI

Color and Line Stile

• Select Profile (Black and White)

• Specify spectrogram Palette (not shown) and Font Setting

• Color setting General

• Specify Function Lines Color and Line Stile for formant tracks (F1 = color #4, F2 = color #5 ….., see „Line“ in profile dialog)

Page 5: Acoustics Research Institute S_TOOLS -STx Supplement Speech Formant Tracking and Fundamental Frequency Extraction Default Parameter Setting.

5

AcousticsResearchInstitute

ARI

Speech Formant Analysis

• Setup: Spectrogramfrequency range, amplitude range,spectrum type

• Setup: Fundamental Frequency Analysis(autocorrelation method)

• Setup: FormantsNote: if the number of coefficients is set to 0sampling frequency in kHz*1.25 is specified

Page 6: Acoustics Research Institute S_TOOLS -STx Supplement Speech Formant Tracking and Fundamental Frequency Extraction Default Parameter Setting.

6

AcousticsResearchInstitute

ARI

Formants: Raw Data

Page 7: Acoustics Research Institute S_TOOLS -STx Supplement Speech Formant Tracking and Fundamental Frequency Extraction Default Parameter Setting.

7

AcousticsResearchInstitute

ARI

Formants: Edit Raw Data

A

B: edit F0-track

C

Mask Out

all Formant

values ofunvoicedframes:

Page 8: Acoustics Research Institute S_TOOLS -STx Supplement Speech Formant Tracking and Fundamental Frequency Extraction Default Parameter Setting.

8

AcousticsResearchInstitute

ARI

Formants: „exchange“

B: edit F2-track

bracket „wrong“ formant segment, edit wrong formant, exchange to correct formant track (F2 to F1).

Page 9: Acoustics Research Institute S_TOOLS -STx Supplement Speech Formant Tracking and Fundamental Frequency Extraction Default Parameter Setting.

9

AcousticsResearchInstitute

ARI

Formants: copy to clipboard & statistics

• Copy formant and fundamental frequency values to clipboard for use in external programs (see further „export parameters“)• perform parameter values raw statistics.

right mouse button