Oct. 2013 1st Edition
ESLON AC DRAIN PIPEESLON AC DRAIN FittingsESLON Transparent AC DRAIN FittingsESLON AC DRAIN Flexible Unit
Most suitable piping
material
for
air conditioning draina
ge
Rigid PVC Pipe and Fittings with anti water condensation layer for air conditioning drainage
ESLON AC Drain Pipe and FittingsCatalogSEKISUI CHEMICAL CO.,LTD.
All rights reserved.
Urban Infrastructure & Environmental Products Company
Oct. 2013 First Edition
http://www.sekisuichemical.com
2013 .10. 0TH TX
Colors of the actual products may vary from the colors shown in this printed material.Information in this document is subject to change without notice.
-
1 21
Installation is identical to a conventional DV connection. There is no outer insulation material. Therefore, inspection work on joint and slope setting is much easy. In addition, visual inspection and securing the joint works are feasible by using Transparent Fittings.
Eslon AC Drain Pipe and Fittings prevent water condensation and do not require any insulation work.It is a perfect fit for air conditioning drainage in office, hotel and hospital, etc.
Can be applied for air conditioning drainage regardless whether the system is packaged air conditioner or fan coil unit.
Packaged Air Conditioner
Pipe for refrigerant gasPipe for refrigerant gas
Drainage Hose, etc.
Pipe for refrigerant liquidPipe for refrigerant liquid
Fi-Block/Fire Protection PVC Pipe
Fi-Block/Fire ProtectionPVC Pipe
Eslon AC Drain Pipe and Fittings
Eslon AC Drain Flexible Unit
Packaged Air Conditioner
Eslon AC Drain Pipe and Fittings System is economical because of easy installation and elimination of insulation work.
Example of AC Drain Pipe Plumbing [In case plumbing length is 13meter]5,000
1,0003,000
1,500
1,500
500
500
Adapter
Adapter25 Elbow
25
25
2525
30
30
25 Elbow
25 Elbow
25 Socket
3025 Socket
3025 90 Tee
AC Drain VP Pipe +Insulation Material(Fitting : Ivory)
SGP (Steel) +Insulation Material
The above is based on publicly announced cost information in Japan.
PlumbingLabor
AC Drain Pipe plumbing is set as 100.
44%
56%
0%100% 109%
13%
12%
34%
50%
192%
34%
86%
12%
60%
InstallationLabor
InsulationMaterial
PlumbingMaterial
Installation Cost Comparison (assume 2 sets of fan coil unit)
Multiple operations were required.
In case of Packaging Air Conditioning
RefrigerantArrangement
Cold and Hot WaterDrainage WorkInsulation Work Insulation WorkDrainage Work
is effective to reduce installation time. is effective to reduce installation time. AC DrainsAC DrainsMultiple works can be eliminated.Multiple works can be eliminated.
withAC Drain
ConventionalMethod
In case of Fan Coil Unit Refrigerant, Drainage,
Insulation Work,
Cold and Hot Water, Drainage and
Insulation Work,
Fan Coil Unit
Pipe for Hot and Cold WaterPipe for Hot and Cold Water
Fi-Block/Fire ProtectionPVC Pipe
Fi-Block/Fire ProtectionPVC Pipe
Eslon AC Drain Pipe and Fittings
Drain Hose, etc.
Fan Coil Unit
Eslon AC Drainage Pipe and Fittings have a function of thermal insulation. Therefore you do not need any insulation work.
D
E
C
Most suitable piping material for air conditioning drainage is AC Drain Pipe and Fittings!
AC Drain Pipe
AC Drain Pipe
Air Conditioning Unit
AC Drain Flexible Unitfor pump up area.
AC Drain Pipe
Mark in this brochure
Caution In case left hand mark is stated, it may cause serious injury or burn wound unless properly treated.
Caution
Items with left hand mark is precaution statement to secure the performance of material
Separately heat up or use AC Drain Flexible Unit for pump up section. May not needed, but please check the condition and determine properly. Category Condition
Application for Air Conditioning Drainage
Water Pressure Under no pressure (Note)
Water Temperature Normal Temperature (5-35C)
Nominal Diameter 20-50
Note: Except pump up whose length is less than 1meter
Applicable RangeCaution
Increase insulation property to prevent moisture condensation.
Feasible to connect pipe and fittings by adhesive.ABS Foamed Layer
Provide a good connection with fitting.
PVC Surface Layer
Secure flow property for drainage.
Rigid PVC Layer
Have superior function in thermal insulation and prevention of water condensation.
Outer DiameterIdentical to VP pipe which is 1 size larger.
PVC Foamed Layer
Same size with standard socket
Cross Linked PE Foam
Main Body of Fitting(ABS)
Provide smooth transition between pipe and fittings for smooth flow of drainage.
Pipe
Fitting (Injection Molded Foam Products)
Water condensation is prevented by foamed layer.
Both Pipe and Fittings have a foamed insulation layer. This prevents whole plumbing from water condensation without having outer insulation material.
o not need insulation work
asy to Install and Improve the Quality
ost Saving
solve all problems!Problems Eslon AC Drain Pipe & Fittingson conventional air conditioning drainage.
Insulation work
It is a time consuming for insulation work.
Cannot check joint and slope angle. Threading is painful work.
Secure the installation Threading work
-
1 21
Installation is identical to a conventional DV connection. There is no outer insulation material. Therefore, inspection work on joint and slope setting is much easy. In addition, visual inspection and securing the joint works are feasible by using Transparent Fittings.
Eslon AC Drain Pipe and Fittings prevent water condensation and do not require any insulation work.It is a perfect fit for air conditioning drainage in office, hotel and hospital, etc.
Can be applied for air conditioning drainage regardless whether the system is packaged air conditioner or fan coil unit.
Packaged Air Conditioner
Pipe for refrigerant gasPipe for refrigerant gas
Drainage Hose, etc.
Pipe for refrigerant liquidPipe for refrigerant liquid
Fi-Block/Fire Protection PVC Pipe
Fi-Block/Fire ProtectionPVC Pipe
Eslon AC Drain Pipe and Fittings
Eslon AC Drain Flexible Unit
Packaged Air Conditioner
Eslon AC Drain Pipe and Fittings System is economical because of easy installation and elimination of insulation work.
Example of AC Drain Pipe Plumbing [In case plumbing length is 13meter]5,000
1,0003,000
1,500
1,500
500
500
Adapter
Adapter25 Elbow
25
25
2525
30
30
25 Elbow
25 Elbow
25 Socket
3025 Socket
3025 90 Tee
AC Drain VP Pipe +Insulation Material(Fitting : Ivory)
SGP (Steel) +Insulation Material
The above is based on publicly announced cost information in Japan.
PlumbingLabor
AC Drain Pipe plumbing is set as 100.
44%
56%
0%100% 109%
13%
12%
34%
50%
192%
34%
86%
12%
60%
InstallationLabor
InsulationMaterial
PlumbingMaterial
Installation Cost Comparison (assume 2 sets of fan coil unit)
Multiple operations were required.
In case of Packaging Air Conditioning
RefrigerantArrangement
Cold and Hot WaterDrainage WorkInsulation Work Insulation WorkDrainage Work
is effective to reduce installation time. is effective to reduce installation time. AC DrainsAC DrainsMultiple works can be eliminated.Multiple works can be eliminated.
withAC Drain
ConventionalMethod
In case of Fan Coil Unit Refrigerant, Drainage,
Insulation Work,
Cold and Hot Water, Drainage and
Insulation Work,
Fan Coil Unit
Pipe for Hot and Cold WaterPipe for Hot and Cold Water
Fi-Block/Fire ProtectionPVC Pipe
Fi-Block/Fire ProtectionPVC Pipe
Eslon AC Drain Pipe and Fittings
Drain Hose, etc.
Fan Coil Unit
Eslon AC Drainage Pipe and Fittings have a function of thermal insulation. Therefore you do not need any insulation work.
D
E
C
Most suitable piping material for air conditioning drainage is AC Drain Pipe and Fittings!
AC Drain Pipe
AC Drain Pipe
Air Conditioning Unit
AC Drain Flexible Unitfor pump up area.
AC Drain Pipe
Mark in this brochure
Caution In case left hand mark is stated, it may cause serious injury or burn wound unless properly treated.
Caution
Items with left hand mark is precaution statement to secure the performance of material
Separately heat up or use AC Drain Flexible Unit for pump up section. May not needed, but please check the condition and determine properly. Category Condition
Application for Air Conditioning Drainage
Water Pressure Under no pressure (Note)
Water Temperature Normal Temperature (5-35C)
Nominal Diameter 20-50
Note: Except pump up whose length is less than 1meter
Applicable RangeCaution
Increase insulation property to prevent moisture condensation.
Feasible to connect pipe and fittings by adhesive.ABS Foamed Layer
Provide a good connection with fitting.
PVC Surface Layer
Secure flow property for drainage.
Rigid PVC Layer
Have superior function in thermal insulation and prevention of water condensation.
Outer DiameterIdentical to VP pipe which is 1 size larger.
PVC Foamed Layer
Same size with standard socket
Cross Linked PE Foam
Main Body of Fitting(ABS)
Provide smooth transition between pipe and fittings for smooth flow of drainage.
Pipe
Fitting (Injection Molded Foam Products)
Water condensation is prevented by foamed layer.
Both Pipe and Fittings have a foamed insulation layer. This prevents whole plumbing from water condensation without having outer insulation material.
o not need insulation work
asy to Install and Improve the Quality
ost Saving
solve all problems!Problems Eslon AC Drain Pipe & Fittingson conventional air conditioning drainage.
Insulation work
It is a time consuming for insulation work.
Cannot check joint and slope angle. Threading is painful work.
Secure the installation Threading work
-
Transparent AC Drain Fittings
NewLine Up!!
NewLine Up!!
AC Drain Flexible Unit
ABS Foamed Layer
Easy to conduct visual check to avoid insufficient adhesive or insufficient insertion.
Transparent Material(ABS)
Main Body
Structure Structure
Feature
Example of plumbing
Characteristics
Easy installation by flexible structureThermal insulated flexible pipe is much easy for installation.
Proper connecting condition
Not insertedsufficiently
No adhesivewas applied
AdhesiveNo. 73SBlue
AdhesiveNo. 75SBlue N
Feasible to check connecting condition visually.
Easy installation for pump up section
Cross linked PE foam Same size to DV socket
Heat insulated flexible pipe
Protective Tape
Socket for Pipe ConnectionSocket for AC Drain
Equipment side elbowPipe Socket
*Please use 65A for vinyl SU pipe to fix fitting, and 32A to fix flexible pipe.
Strap support structureFeasible to conduct proper plumbing by fixing both fitting and hose.
Thermal Insulation is not required.No insulation work is required for entire pipeline by use of AC Drain Flexible Unit and AC Drain Pipe & Fittings.
Heat insulation
Preventwater
condensation
Please refer to page 7 for specification.Easy to check connecting condition Refer Page 5, 6, 7 for product line and specification.
Sealing Material
Thermal Insulated Flexible Hose
Socket
AC Drain Pipe
Fix Fitting
Fix Flexible Pipe
Transparent AC Drain FittingsTransparent AC Drain Fittings
AC Drain PipeAC Drain Pipe
For pump up section
Superior in thermal insulationHigh thermal insulation property allows not to use insulation material even in full of water section.*In case of identical use condition to AC Drain
Feasible to connect to AC DrainIt has an identical sealing material. Connection to AC Drain Pipe is feasible.
No insulation work is needed
Extended View
VP25Flexible Hose
Hose Band
AC Drain25
Feasible to check visually about the adhesive condition between pipe and fittings with the use of blue adhesive.
Use Eslon Adhesive No. 73S Blue or No. 75S Blue N for the use of transparent AC drain fitting.
3 44
-
Transparent AC Drain Fittings
NewLine Up!!
NewLine Up!!
AC Drain Flexible Unit
ABS Foamed Layer
Easy to conduct visual check to avoid insufficient adhesive or insufficient insertion.
Transparent Material(ABS)
Main Body
Structure Structure
Feature
Example of plumbing
Characteristics
Easy installation by flexible structureThermal insulated flexible pipe is much easy for installation.
Proper connecting condition
Not insertedsufficiently
No adhesivewas applied
AdhesiveNo. 73SBlue
AdhesiveNo. 75SBlue N
Feasible to check connecting condition visually.
Easy installation for pump up section
Cross linked PE foam Same size to DV socket
Heat insulated flexible pipe
Protective Tape
Socket for Pipe ConnectionSocket for AC Drain
Equipment side elbowPipe Socket
*Please use 65A for vinyl SU pipe to fix fitting, and 32A to fix flexible pipe.
Strap support structureFeasible to conduct proper plumbing by fixing both fitting and hose.
Thermal Insulation is not required.No insulation work is required for entire pipeline by use of AC Drain Flexible Unit and AC Drain Pipe & Fittings.
Heat insulation
Preventwater
condensation
Please refer to page 7 for specification.Easy to check connecting condition Refer Page 5, 6, 7 for product line and specification.
Sealing Material
Thermal Insulated Flexible Hose
Socket
AC Drain Pipe
Fix Fitting
Fix Flexible Pipe
Transparent AC Drain FittingsTransparent AC Drain Fittings
AC Drain PipeAC Drain Pipe
For pump up section
Superior in thermal insulationHigh thermal insulation property allows not to use insulation material even in full of water section.*In case of identical use condition to AC Drain
Feasible to connect to AC DrainIt has an identical sealing material. Connection to AC Drain Pipe is feasible.
No insulation work is needed
Extended View
VP25Flexible Hose
Hose Band
AC Drain25
Feasible to check visually about the adhesive condition between pipe and fittings with the use of blue adhesive.
Use Eslon Adhesive No. 73S Blue or No. 75S Blue N for the use of transparent AC drain fitting.
3 44
-
5 66
Lineup of Eslon AC Drain Pipe and Fittings
Z
L
Z
L
45
2025304050
1416182226
3335414862
801601006030
AC4L20NAC4L25NAC4L30NAC4L40NAC4L50N
AC4L20SAC4L25SAC4L30SAC4L40SAC4L50S
EffectiveLength Z
NominalDiameter
LengthL
Quantityper package
IvoryPart #
TransparentPart #
Unit:mm
45Elbow
Z2Z1
L2L1
L3
Z3 9110
232623312326382326314623263138
232623312326382326314724273239
232626313131383837374646464646
4010040602460302040402020202020
2025
252030
3020302540
40204025403050
5020502550305040
ACT20NACT25NACT251NACT30NACT302NACT301NACT40NACT403NACT402NACT401NACT50NACT504NACT503NACT502NACT501N
ACT20SACT25SACT251SACT30SACT302SACT301SACT40SACT403SACT402SACT401SACT50SACT504SACT503SACT502SACT501S
Z1 Z2 Z3 L1424542544649644952578259626774
L2424542544649644952578360636875
L3424545545050645756608265646972
NominalDiameter
Effective Length Length Quantityper package
IvoryPart #
TransparentPart #
Unit:mm90Tee
L2L1
L3
Z2
Z1 Z3
45
16242412
62769684
668210292
30251415
304050
5040
ACY30NACY40NACY50NACY501N
ACY30SACY40SACY50SACY501S
Z1 Z2 Z3 L139506048
L285102132120
L389108138118
NominalDiameter
Effective Length Length Quantityper package
IvoryPart #
TransparentPart #
Unit:mm
L
Tt
D
Part # NominalDiameterQuantity
per package
32.038.048.060.076.0
4,000
2025304050
ACD20PACD25PACD30PACD40PACD50P
6.56.58.59.09.5
1.72.02.02.22.5
19.025.031.042.057.0
0.410.500.721.001.41
1612964
Unit:mmOuter
DiameterD
LengthL
ThicknessT
Approximate Inner Diameter
(Reference)
Thickness of rigidPVC layer
t
Reference Weight(kg/m)
9110
L
Z
L
Z
EffectiveLength Z
LengthL
IvoryPart #
TransparentPart #
Quantityper package
2025304050
2326313746
4245546382
801601005020
ACL20NACL25NACL30NACL40NACL50N
ACL20SACL25SACL30SACL40SACL50S
NominalDiameter
Unit:mm
NominalDiameter
Inner Diameter Length ofSocket
Pipe Thicknesst1(Minimum)
Pipe Thicknesst2(Minimum)d1 d2 d
2025304050
32.2538.2548.3060.3576.40
31.8537.8547.8059.7575.70
19.025.031.042.057.0
2323273040
8.58.58.79.19.4
2.72.72.73.13.1
Unit:mm
t2t2t1
d2
d
d1
t1
d2
d
d1
t2t2t1
d2
d
d1
t1
d2
d
d1
Injection Molded Foam Products Injection Molded Product
Pipe
Fittings Socket Dimension (Common)
90Elbow
45Y
L
Z 2025
252030
302540
403050
5040
111113111211131113
494951575463628375
12024080160180801004060
ACS20NACS25NACS251NACS30NACS301NACS40NACS401NACS50NACS501N
ACS20SACS25SACS251SACS30SACS301SACS40SACS401SACS50SACS501S
NominalDiameter
EffectiveLength Z
LengthL
Quantityper package
IvoryPart #
TransparentPart #
Unit:mmSocket
Z
D
L
3439172124
TS20TS25DV30DV40DV50
26.032.038.048.060.0
Remarks: 1. Refer to Page 8 how to apply2. Connect same nominal diameter of AC Drain for female socket. Use TS fitting for spigot side in nominal diameter 20, 25 and DV fitting in nominal diameter of 30, 40 and 50 (TS fitting is not applicable for those diameters).
2025304050
4146242932
606547.55564.5
10080805030
ACDA20ACDA25ACDA30ACDA40ACDA50
ACA20SACA25SACA30SACA40SACA50S
DInlet Spigot
side FittingNominalDiameter
EffectiveLength Z
LengthL
Quantityper package
IvoryPart #
TransparentPart #
Unit:mmNominal Diameter 20, 25
Nominal Diameter 30, 40, 50
Adapter (Transition Fitting to PVC Pipe)
Z
D
L
7276
MD Fitting40MD Fitting50
4860
Remarks: 1. Connect identical nominal diameter AC Drain Pipe for socket side. Connect MD Fitting for spigot side (Do not apply TS Fitting or DV Fitting for spigot side)2. Do not cut and use spigot3. Conduct thermal insulation for spigot side
LengthL
4050
8084
105119
Quantityper
Package
IvoryPart #
TransparentPart #
1225
ACMD40ACMD50
ACMD40SACMD50S
DSpigot Spigot
side FittingEffectiveLength Z
NominalDiameter
Unit:mm
Adapter for MD Fitting NEW
-
5 66
Lineup of Eslon AC Drain Pipe and Fittings
Z
L
Z
L
45
2025304050
1416182226
3335414862
801601006030
AC4L20NAC4L25NAC4L30NAC4L40NAC4L50N
AC4L20SAC4L25SAC4L30SAC4L40SAC4L50S
EffectiveLength Z
NominalDiameter
LengthL
Quantityper package
IvoryPart #
TransparentPart #
Unit:mm
45Elbow
Z2Z1
L2L1
L3
Z3 9110
232623312326382326314623263138
232623312326382326314724273239
232626313131383837374646464646
4010040602460302040402020202020
2025
252030
3020302540
40204025403050
5020502550305040
ACT20NACT25NACT251NACT30NACT302NACT301NACT40NACT403NACT402NACT401NACT50NACT504NACT503NACT502NACT501N
ACT20SACT25SACT251SACT30SACT302SACT301SACT40SACT403SACT402SACT401SACT50SACT504SACT503SACT502SACT501S
Z1 Z2 Z3 L1424542544649644952578259626774
L2424542544649644952578360636875
L3424545545050645756608265646972
NominalDiameter
Effective Length Length Quantityper package
IvoryPart #
TransparentPart #
Unit:mm90Tee
L2L1
L3
Z2
Z1 Z3
45
16242412
62769684
668210292
30251415
304050
5040
ACY30NACY40NACY50NACY501N
ACY30SACY40SACY50SACY501S
Z1 Z2 Z3 L139506048
L285102132120
L389108138118
NominalDiameter
Effective Length Length Quantityper package
IvoryPart #
TransparentPart #
Unit:mm
L
Tt
D
Part # NominalDiameterQuantity
per package
32.038.048.060.076.0
4,000
2025304050
ACD20PACD25PACD30PACD40PACD50P
6.56.58.59.09.5
1.72.02.02.22.5
19.025.031.042.057.0
0.410.500.721.001.41
1612964
Unit:mmOuter
DiameterD
LengthL
ThicknessT
Approximate Inner Diameter
(Reference)
Thickness of rigidPVC layer
t
Reference Weight(kg/m)
9110
L
Z
L
Z
EffectiveLength Z
LengthL
IvoryPart #
TransparentPart #
Quantityper package
2025304050
2326313746
4245546382
801601005020
ACL20NACL25NACL30NACL40NACL50N
ACL20SACL25SACL30SACL40SACL50S
NominalDiameter
Unit:mm
NominalDiameter
Inner Diameter Length ofSocket
Pipe Thicknesst1(Minimum)
Pipe Thicknesst2(Minimum)d1 d2 d
2025304050
32.2538.2548.3060.3576.40
31.8537.8547.8059.7575.70
19.025.031.042.057.0
2323273040
8.58.58.79.19.4
2.72.72.73.13.1
Unit:mm
t2t2t1
d2
d
d1
t1
d2
d
d1
t2t2t1
d2
d
d1
t1
d2
d
d1
Injection Molded Foam Products Injection Molded Product
Pipe
Fittings Socket Dimension (Common)
90Elbow
45Y
L
Z 2025
252030
302540
403050
5040
111113111211131113
494951575463628375
12024080160180801004060
ACS20NACS25NACS251NACS30NACS301NACS40NACS401NACS50NACS501N
ACS20SACS25SACS251SACS30SACS301SACS40SACS401SACS50SACS501S
NominalDiameter
EffectiveLength Z
LengthL
Quantityper package
IvoryPart #
TransparentPart #
Unit:mmSocket
Z
D
L
3439172124
TS20TS25DV30DV40DV50
26.032.038.048.060.0
Remarks: 1. Refer to Page 8 how to apply2. Connect same nominal diameter of AC Drain for female socket. Use TS fitting for spigot side in nominal diameter 20, 25 and DV fitting in nominal diameter of 30, 40 and 50 (TS fitting is not applicable for those diameters).
2025304050
4146242932
606547.55564.5
10080805030
ACDA20ACDA25ACDA30ACDA40ACDA50
ACA20SACA25SACA30SACA40SACA50S
DInlet Spigot
side FittingNominalDiameter
EffectiveLength Z
LengthL
Quantityper package
IvoryPart #
TransparentPart #
Unit:mmNominal Diameter 20, 25
Nominal Diameter 30, 40, 50
Adapter (Transition Fitting to PVC Pipe)
Z
D
L
7276
MD Fitting40MD Fitting50
4860
Remarks: 1. Connect identical nominal diameter AC Drain Pipe for socket side. Connect MD Fitting for spigot side (Do not apply TS Fitting or DV Fitting for spigot side)2. Do not cut and use spigot3. Conduct thermal insulation for spigot side
LengthL
4050
8084
105119
Quantityper
Package
IvoryPart #
TransparentPart #
1225
ACMD40ACMD50
ACMD40SACMD50S
DSpigot Spigot
side FittingEffectiveLength Z
NominalDiameter
Unit:mm
Adapter for MD Fitting NEW
-
7 88
Installation procedure of Eslon AC Drain Pipe and Fittings
Connection to different pipe
Mark cutting line for whole circumference and cut at right angle against axis by saw.
Apply Eslon adhesive (No. 73S Blue, No. 75S Blue N, No. 73S, No. 75S) evenly to inner surface of fitting, at the edge face of pipe and outer surface of pipe.
Conduct light-chamfering for both inner and outer surface on the edge of pipe.
Do not use PVC cutter, etc. that may cause crack or chap.
5 Apply adhesive
2 Chamfer
1 Cut
Remove sand, soil or dust, etc. and water content attached to the inner surface of socket or inserting section of pipe by cloth.
Mark inserting length to the pipe stated below.
Insert pipe quickly till marked section is covered.
Insert pipe quickly till the end.
6 Insert
7 Hold (wipe off adhesive / ventilation)Hold pipe and fittings more than 30 seconds.Wipe off adhesive that comes out of the section by cloth.Please provide sufficient ventilation after insertion.
In case of rough surface, it would remove adhesive on the socket and cause loose.
Please apply adhesive not only to inner surface of fitting, outer surface of pipe but also to the edge face of pipe.
Please use adhesive No. 73S Blue or No. 75S Blue N for transparent AC Drain fitting.
Reference) Inserting Length Unit: mmNominal Diameter
Inserting Length
20
19
25
19
30
23
40
26
50
36
The outer diameter of AC Drain Pipe against nominal diameter is identical to 1 size larger outer diameter of PVC pipe. Thus, supporting claps, etc. for PVC pipe can be used.
Arrange the pitch of support to AC Drain Pipe identical to standard VP pipe whose diameter is identical.
Apply adhesive for edge face of pipe
3 Wipe off
4 Mark inserting length* Clean with slight amount of industrial alcohol in
case oil is attached to the connecting section.
Marking for inserting section
Apply adhesive for outer surface of pipe
Please make sure to use AC Drain Transition Fittingto connect to the difference pipe.
(1) Connecting AC Drain Pipe to PVC pipe in nominal diameter of 20 and 25 (use TS Fitting)
Connect with the combination of adapter fitting and TS fitting.
Caution
Thermal insulation is required for VP Pipe and TS Fitting. *Can be used to connect to drain hose as well.
(2) Connecting AC Drain Pipe to PVC pipe in nominal diameter of 30, 40 and 50 (use DV Fitting)
Connect with the combination of adapter fitting and DV fitting.
Caution
Thermal insulation is required for VP Pipe and DV Fitting.
Caution
The dimension of inserting section is for DV fitting. TS fitting cannot be used.
(3) In case connecting MD Fitting and AC Drain Pipe
Use MD Fitting Adapter.
Caution
Do not cut spigot.
Caution
Do not connect to TS or DV Fitting for spigot side.
Caution
Need thermal insulation treatment on inserting area of MD Fitting Adapter and MD Fitting
VP Pipe 25 VP Pipe 50AC Drain Pipe 25
AC Drain Pipe 50TS Fitting 25
TS Socket in same nominal diameter
DV Fitting50
Adapter25
Adapter50
DV Socket in same nominal diameterAC DrainPipe 40
MD FittingConnectingAdapter 40
MD Fitting 40
VP Pipe 25 VP Pipe 50AC Drain Pipe 25
AC Drain Pipe 50TS Fitting 25
TS Socket in same nominal diameter
DV Fitting50
Adapter25
Adapter50
DV Socket in same nominal diameterAC DrainPipe 40
MD FittingConnectingAdapter 40
MD Fitting 40
VP Pipe 25 VP Pipe 50AC Drain Pipe 25
AC Drain Pipe 50TS Fitting 25
TS Socket in same nominal diameter
DV Fitting50
Adapter25
Adapter50
DV Socket in same nominal diameterAC DrainPipe 40
MD FittingConnectingAdapter 40
MD Fitting 40
Installation Process
Lineup of Eslon AC Drain Pipe and Fittings
L2
L3
D2
O Ring
D3D1
L1
D1Clamp Torque
(N m)
2025304050
JNCO25NJNCO30NJNCO40NJNCO50NJNCO65N
22455
4145556884
D2
2732415169
D3
3238486076
L1
1919232636
L2 L3
42.541.244.547.557.5
17.519.5242936
20020024013268
Remarks: 1. Do not use where contacting water continuously. It may cause water condensation.2. 1 Size larger nominal diameter is stated to AC Drain.
AC DrainNominalDiameter
Quantityper package
IvoryPart #
Unit:mm
Related Products
L1
L2d1 d2
d1
d2
L1
1,000
Protective Tape
EquipmentSide Elbow Plumbing
Side Socket
Material
25 Equipment SidePipe Side
d1
32.2538.25
d2
31.8537.85
2518
Z1 Z2
35 36
L1
6031
L2
73--
ACFU255
Remarks: Equipment side meets to VP25 and Pipe side meets AC Drain 25
NominalDiameter
Quantityper
packageIvory
Transparent
Unit:mm
AC Drain Flexible Unit
Screw type cleaning hole
Eslon Adhesive
Remarks: Use either No. 73S Blue or No. 75S Blue N for transparent AC Drain Fitting.
Use it as standard adhesive for AC Drain
Volume: 500g (w/ Brush) 1 kg (w/ Brush)
No. 73S Blue
Volume: 500g (w/ Brush) 1 kg (w/ Brush)
No. 75S Blue N Volume:
500g (w/ Brush) 1 kg (w/ Brush)
No.73S
Volume: 500g (w/ Brush) 1 kg (w/ Brush)
No.75S
-
7 88
Installation procedure of Eslon AC Drain Pipe and Fittings
Connection to different pipe
Mark cutting line for whole circumference and cut at right angle against axis by saw.
Apply Eslon adhesive (No. 73S Blue, No. 75S Blue N, No. 73S, No. 75S) evenly to inner surface of fitting, at the edge face of pipe and outer surface of pipe.
Conduct light-chamfering for both inner and outer surface on the edge of pipe.
Do not use PVC cutter, etc. that may cause crack or chap.
5 Apply adhesive
2 Chamfer
1 Cut
Remove sand, soil or dust, etc. and water content attached to the inner surface of socket or inserting section of pipe by cloth.
Mark inserting length to the pipe stated below.
Insert pipe quickly till marked section is covered.
Insert pipe quickly till the end.
6 Insert
7 Hold (wipe off adhesive / ventilation)Hold pipe and fittings more than 30 seconds.Wipe off adhesive that comes out of the section by cloth.Please provide sufficient ventilation after insertion.
In case of rough surface, it would remove adhesive on the socket and cause loose.
Please apply adhesive not only to inner surface of fitting, outer surface of pipe but also to the edge face of pipe.
Please use adhesive No. 73S Blue or No. 75S Blue N for transparent AC Drain fitting.
Reference) Inserting Length Unit: mmNominal Diameter
Inserting Length
20
19
25
19
30
23
40
26
50
36
The outer diameter of AC Drain Pipe against nominal diameter is identical to 1 size larger outer diameter of PVC pipe. Thus, supporting claps, etc. for PVC pipe can be used.
Arrange the pitch of support to AC Drain Pipe identical to standard VP pipe whose diameter is identical.
Apply adhesive for edge face of pipe
3 Wipe off
4 Mark inserting length* Clean with slight amount of industrial alcohol in
case oil is attached to the connecting section.
Marking for inserting section
Apply adhesive for outer surface of pipe
Please make sure to use AC Drain Transition Fittingto connect to the difference pipe.
(1) Connecting AC Drain Pipe to PVC pipe in nominal diameter of 20 and 25 (use TS Fitting)
Connect with the combination of adapter fitting and TS fitting.
Caution
Thermal insulation is required for VP Pipe and TS Fitting. *Can be used to connect to drain hose as well.
(2) Connecting AC Drain Pipe to PVC pipe in nominal diameter of 30, 40 and 50 (use DV Fitting)
Connect with the combination of adapter fitting and DV fitting.
Caution
Thermal insulation is required for VP Pipe and DV Fitting.
Caution
The dimension of inserting section is for DV fitting. TS fitting cannot be used.
(3) In case connecting MD Fitting and AC Drain Pipe
Use MD Fitting Adapter.
Caution
Do not cut spigot.
Caution
Do not connect to TS or DV Fitting for spigot side.
Caution
Need thermal insulation treatment on inserting area of MD Fitting Adapter and MD Fitting
VP Pipe 25 VP Pipe 50AC Drain Pipe 25
AC Drain Pipe 50TS Fitting 25
TS Socket in same nominal diameter
DV Fitting50
Adapter25
Adapter50
DV Socket in same nominal diameterAC DrainPipe 40
MD FittingConnectingAdapter 40
MD Fitting 40
VP Pipe 25 VP Pipe 50AC Drain Pipe 25
AC Drain Pipe 50TS Fitting 25
TS Socket in same nominal diameter
DV Fitting50
Adapter25
Adapter50
DV Socket in same nominal diameterAC DrainPipe 40
MD FittingConnectingAdapter 40
MD Fitting 40
VP Pipe 25 VP Pipe 50AC Drain Pipe 25
AC Drain Pipe 50TS Fitting 25
TS Socket in same nominal diameter
DV Fitting50
Adapter25
Adapter50
DV Socket in same nominal diameterAC DrainPipe 40
MD FittingConnectingAdapter 40
MD Fitting 40
Installation Process
Lineup of Eslon AC Drain Pipe and Fittings
L2
L3
D2
O Ring
D3D1
L1
D1Clamp Torque
(N m)
2025304050
JNCO25NJNCO30NJNCO40NJNCO50NJNCO65N
22455
4145556884
D2
2732415169
D3
3238486076
L1
1919232636
L2 L3
42.541.244.547.557.5
17.519.5242936
20020024013268
Remarks: 1. Do not use where contacting water continuously. It may cause water condensation.2. 1 Size larger nominal diameter is stated to AC Drain.
AC DrainNominalDiameter
Quantityper package
IvoryPart #
Unit:mm
Related Products
L1
L2d1 d2
d1
d2
L1
1,000
Protective Tape
EquipmentSide Elbow Plumbing
Side Socket
Material
25 Equipment SidePipe Side
d1
32.2538.25
d2
31.8537.85
2518
Z1 Z2
35 36
L1
6031
L2
73--
ACFU255
Remarks: Equipment side meets to VP25 and Pipe side meets AC Drain 25
NominalDiameter
Quantityper
packageIvory
Transparent
Unit:mm
AC Drain Flexible Unit
Screw type cleaning hole
Eslon Adhesive
Remarks: Use either No. 73S Blue or No. 75S Blue N for transparent AC Drain Fitting.
Use it as standard adhesive for AC Drain
Volume: 500g (w/ Brush) 1 kg (w/ Brush)
No. 73S Blue
Volume: 500g (w/ Brush) 1 kg (w/ Brush)
No. 75S Blue N Volume:
500g (w/ Brush) 1 kg (w/ Brush)
No.73S
Volume: 500g (w/ Brush) 1 kg (w/ Brush)
No.75S
-
9 1010
Installation Procedure of AC Drain Flexible Unit
3 Connection of Elbow on device side
4 Fix support of elbow on device side
5 Connect socket to pipe side
6 Fix support for heat insulating flexible pipe
2
Chamfer
1 Air conditioner and horizontal drain plumbing
Flexible Hose Elbow
Plumbing side socket
Horizontal Drain Plumbing.(AC Drain Pipe, Fitting)
Secure the hanging position of support
Air Conditioner
Applyadhesive to edge face of pipe
Indicating mark for insertion
Apply adhesive to outer surface of pipe Socket on pipe side
AC Drain Pipe
Flexible Hose
Socket on pipe side
Air ConditionerHeat insulating flexible pipe
Protective TapeFix and support heat insulating flexible pipe + wrap by protective tape included in the package
Flexible Hose
Support and FixDent
Supporting clasp: 65A for Vinyl SU pipe
Elbow on device side
Air Conditioner
Flexible Hose Elbow
Flexible Hose
Elbow
Air Conditioner
Arrange the distance of plumbing below 700mm between flexible hose attached to air conditioner and horizontal drain plumbing. Also, please arrange the maximum height of AC Drain Flexible Unit less than the maximum height specified by air conditioner manufacturer.
In case of bringing up AC Drain Flexible Unit from air conditioner, the height should be arranged less than the maximum height air conditioner manufacturer specifies. Also, the length of horizontal plumbing should not have excess tension (less than 700mm).
Fix support firmly to dent of elbow on device side(Supporting clasp: 65A for Vinyl SU pipe)
Connect supporting clasp to the dent of elbow on device side, and fix flexible hose not to deflect it.
Apply Eslon adhesive evenly to socket on pipe side and Drain horizontal plumbing (AC Drain Pipe 25A), and insert till the end.
Do not drag or bend from elbow too much.
Also, do not twist heat insulating flexible pipe.
*Apply adhesive to edge face of AC Drain Pipe in case of connecting AC Drain Pipe to socket on pipe side.
Wrap protective tape at the top of bring up section, and firmly fix the support.(Applicable supporting claps : 32A for SGP Pipe)
Wrap by protective tape included in the package before fixing heat insulating flexible pipe by claps.
Please do not cause back draft from brought up section.
Please do not drag or bend heat insulating flexible pipe too much.
Please do not bend heat insulating flexible pipe less than minimum bending radius of 111mm.
Check connecting position of elbow on air conditioner side to decide the position of support.
Check the position of support
Elbow on device side requires support. Please make sure to arrange support to it.
Apply Eslon adhesive (No. 73S Blue, No. 75S Blue N, No. 73S, No. 75S) evenly to elbow on device side and VP 25 connected to the edge of flexible hose.Then, insert till the end.
Please pay attention not to apply adhesive to thermal insulating flexible pipe.
Please check VP25A short pipe is feasible to connect in case of using flexible hose included as attachment to an air conditioner. Also, please note insulation treatment is needed for that short pipe section.
*Please follow standard procedure for DV fitting in case connecting by adhesive.
Twist of heat insulating flexible pipe
Flexible Hose
Socket on pipe side
AC Drain Pipe
Air Conditioner
Extended View
Below 700mmLength of horizontal plumbingFlexible Hose
Elbow
Socket
AC Drain Pipe,Fitting
Air Conditioner
Height
VP25Flexible Hose
Hose Band
Installation Process
Performance of Eslon AC Drain Pipe, Fitting and AC Drain Flexible Unit
Capability to prevent moisture condensation Condition:Nominal diameter 25, Flow amount 3 liter/hour,
Pipe Slope 1/50
Caution
Performance of AC Drain Pipe and Fittings in horizontal
plumbing, and AC Drain Flexible Unit on brought up section.
Please conduct thermal insulation separately in case AC
Drain Pipe and Fittings are applied for full water area
including brought up section.
It may not needed depends on the condition. Please check
the condition to determine.
10 15 20 25 30
Rela
tive
Hum
idity
(%)
Outer Temperature ( C )
Area water condensation
occurs
Area water condensation
occurs
60
65
70
75
80
85
90
95
100Water Temperature 15C Water Temperature 10C
10 15 20 25 30
Rela
tive
Hum
idity
(%)
Outer Temperature ( C )
60
65
70
75
80
85
90
95
100
Area not to causewater condensation
Area not to causewater condensation
10 15 20 25 30
Rela
tive
Hum
idity
(%)
Outer Temperature ( C )
Area water condensation
occurs
Area water condensation
occurs
60
65
70
75
80
85
90
95
100Water Temperature 15C Water Temperature 10C
10 15 20 25 30
Rela
tive
Hum
idity
(%)
Outer Temperature ( C )
60
65
70
75
80
85
90
95
100
Area not to causewater condensation
Area not to causewater condensation
[Note]VP Pipe ........ Standard PVC Pipe which is durable for water hammer pressure of 1.0MPa DV Fitting ..... PVC fitting for non pressure application including drainpipeTS Fitting ..... PVC fitting for pressure applicationMD Fitting .... Cast finishing fitting for non pressure applicationSU Pipe ....... Thin walled PVC Pipe
Those definitions come from Japanese Industrial Standards. Please consult in case detailed information is needed.
-
9 1010
Installation Procedure of AC Drain Flexible Unit
3 Connection of Elbow on device side
4 Fix support of elbow on device side
5 Connect socket to pipe side
6 Fix support for heat insulating flexible pipe
2
Chamfer
1 Air conditioner and horizontal drain plumbing
Flexible Hose Elbow
Plumbing side socket
Horizontal Drain Plumbing.(AC Drain Pipe, Fitting)
Secure the hanging position of support
Air Conditioner
Applyadhesive to edge face of pipe
Indicating mark for insertion
Apply adhesive to outer surface of pipe Socket on pipe side
AC Drain Pipe
Flexible Hose
Socket on pipe side
Air ConditionerHeat insulating flexible pipe
Protective TapeFix and support heat insulating flexible pipe + wrap by protective tape included in the package
Flexible Hose
Support and FixDent
Supporting clasp: 65A for Vinyl SU pipe
Elbow on device side
Air Conditioner
Flexible Hose Elbow
Flexible Hose
Elbow
Air Conditioner
Arrange the distance of plumbing below 700mm between flexible hose attached to air conditioner and horizontal drain plumbing. Also, please arrange the maximum height of AC Drain Flexible Unit less than the maximum height specified by air conditioner manufacturer.
In case of bringing up AC Drain Flexible Unit from air conditioner, the height should be arranged less than the maximum height air conditioner manufacturer specifies. Also, the length of horizontal plumbing should not have excess tension (less than 700mm).
Fix support firmly to dent of elbow on device side(Supporting clasp: 65A for Vinyl SU pipe)
Connect supporting clasp to the dent of elbow on device side, and fix flexible hose not to deflect it.
Apply Eslon adhesive evenly to socket on pipe side and Drain horizontal plumbing (AC Drain Pipe 25A), and insert till the end.
Do not drag or bend from elbow too much.
Also, do not twist heat insulating flexible pipe.
*Apply adhesive to edge face of AC Drain Pipe in case of connecting AC Drain Pipe to socket on pipe side.
Wrap protective tape at the top of bring up section, and firmly fix the support.(Applicable supporting claps : 32A for SGP Pipe)
Wrap by protective tape included in the package before fixing heat insulating flexible pipe by claps.
Please do not cause back draft from brought up section.
Please do not drag or bend heat insulating flexible pipe too much.
Please do not bend heat insulating flexible pipe less than minimum bending radius of 111mm.
Check connecting position of elbow on air conditioner side to decide the position of support.
Check the position of support
Elbow on device side requires support. Please make sure to arrange support to it.
Apply Eslon adhesive (No. 73S Blue, No. 75S Blue N, No. 73S, No. 75S) evenly to elbow on device side and VP 25 connected to the edge of flexible hose.Then, insert till the end.
Please pay attention not to apply adhesive to thermal insulating flexible pipe.
Please check VP25A short pipe is feasible to connect in case of using flexible hose included as attachment to an air conditioner. Also, please note insulation treatment is needed for that short pipe section.
*Please follow standard procedure for DV fitting in case connecting by adhesive.
Twist of heat insulating flexible pipe
Flexible Hose
Socket on pipe side
AC Drain Pipe
Air Conditioner
Extended View
Below 700mmLength of horizontal plumbingFlexible Hose
Elbow
Socket
AC Drain Pipe,Fitting
Air Conditioner
Height
VP25Flexible Hose
Hose Band
Installation Process
Performance of Eslon AC Drain Pipe, Fitting and AC Drain Flexible Unit
Capability to prevent moisture condensation Condition:Nominal diameter 25, Flow amount 3 liter/hour,
Pipe Slope 1/50
Caution
Performance of AC Drain Pipe and Fittings in horizontal
plumbing, and AC Drain Flexible Unit on brought up section.
Please conduct thermal insulation separately in case AC
Drain Pipe and Fittings are applied for full water area
including brought up section.
It may not needed depends on the condition. Please check
the condition to determine.
10 15 20 25 30
Rela
tive
Hum
idity
(%)
Outer Temperature ( C )
Area water condensation
occurs
Area water condensation
occurs
60
65
70
75
80
85
90
95
100Water Temperature 15C Water Temperature 10C
10 15 20 25 30
Rela
tive
Hum
idity
(%)
Outer Temperature ( C )
60
65
70
75
80
85
90
95
100
Area not to causewater condensation
Area not to causewater condensation
10 15 20 25 30
Rela
tive
Hum
idity
(%)
Outer Temperature ( C )
Area water condensation
occurs
Area water condensation
occurs
60
65
70
75
80
85
90
95
100Water Temperature 15C Water Temperature 10C
10 15 20 25 30
Rela
tive
Hum
idity
(%)
Outer Temperature ( C )
60
65
70
75
80
85
90
95
100
Area not to causewater condensation
Area not to causewater condensation
[Note]VP Pipe ........ Standard PVC Pipe which is durable for water hammer pressure of 1.0MPa DV Fitting ..... PVC fitting for non pressure application including drainpipeTS Fitting ..... PVC fitting for pressure applicationMD Fitting .... Cast finishing fitting for non pressure applicationSU Pipe ....... Thin walled PVC Pipe
Those definitions come from Japanese Industrial Standards. Please consult in case detailed information is needed.
-
11
1.Cautions at the stage of planning
This is piping material for drainage of air conditioner. Do not use for pressure application except air conditioner pump up application (below 1mm).
Please arrange thermal insulation for the section where water is full such as at the top of pump up section. Water condensation may occurr in that area. It may not happen depends on the condition, but please check it.
The applicable area is for indoor only. Do not apply for exterior.
Treatment with Fi-Block is required for area where fire proof is required.
Steel bar hook (all screw bolt hook) is standard procedure for horizontal plumbing.
Straight plumbing should be less than 30 meter. Arrange elbow every 30 meters (more than 2 elbows: Pitch of elbow more than 0.5 meter).
2.Caution at storage
Arrange the pitch of support to AC Drain Pipe identical to same size of PVC pipe (VP).
Store pipe and fittings inside of a room. Cover by sheet with avoiding to retain heat in case it needs to store outside.
Do not use fire in storage room. Fire spark or heat may cause damage to pipe and fittings.
Do not store solvent or paint in storage room. Attack by organic solvent, etc. may cause damage.
3. Caution for transportation
Whole coverage by corrugate board is required, since AC Drain pipe has foamed layer and soft. Need to be handled more carefully than PVC pipe. Never drag or throw.
4.Caution for installation of AC Drain Pipe and Fittings
Use Eslon Adhesive No. 73S Blue, No. 75S Blue N, No. 73S, No. 75S.
Use Eslon Adhesive No. 73S Blue or No. 75S Blue N for transparent AC Drain Fitting.
Please follow instruction to install Eslon AC Drain Pipe and Fittings on page 8.
Please follow the requirements stated below for connection between AC Drain and PVC pipe.The gap at the joint may cause accumulation of water or moisture condensation.
** Make sure to use AC Drain plumbing system with combination of AC Drain Pipe and AC Drain Fittings.
** Make sure to use adapter fitting (refer to page 6) to connect AC Drain Pipe and PVC pipe.
Use 1 size larger fitting of PVC pipe for screw type cleaning hole (joint section needs another thermal insulation).
5. Caution for installation of AC Drain Flexible Unit
Do not drag or bend from the point of fitting.
Do not step on fitting, hose or area where is close to joint. Do not use hose once it has been stepped on even there is no damage visually.
Please minimize the twist for plumbing.
Do not flush chemical liquid (surface activating agent, organic solvent, acid, alkali, etc) or solid content except drain.
Please pay attention not to cause buckling in case supporting material is used.
Do not use hose which had buckling or stepped on even there is no visual damage.
Please replace to new hose in case of re-arranging plumbing such as renewal of air conditioner. It is not feasible for reuse once installed.
Arrange minimum bending radius within 3 times of outer diameter for Drain Pipe.
6. Other cautions
Cut and remove the section in case there is crack, dint or deflection.
In case pipe and fittings are attacked by creosote, asphalt, antiseptic, waterproof agent or ketone, it may swell and break. Please avoid contact of those materials to pipe and fittings.
Do not run liquid that containts solvent, ethanol, chlorine, glycoether or ricinus. It may break pipe and result in leakage of liquid. Please pay attention especially when cleaning inside of air conditioner by chemical solution.
Do not step on or hang on pipe.
Avoid fire cause near this product that comes from spark by electric welding, torch lamp or gas barner, etc.
Follow the instruction from gas equipment manufacturer and association concerning the distance to gas equipment such as gas water heater. The condition may differ by the type of equipment. Thus, please consult the distance with gas business operator or manufacturer.
Do not allocate pipes near direct heat such as stove burner.
Do not flush chemical content such as solvent, ethanol or chlorine based material. It may break pipe and results in leakage. Please pay attention especially when cleaning the equipment by chemical solution.
In case the volume of adhesive exceeds allowable level, regulation of intoxiation prevention may apply. Detail needs to be checked with local labor standards inspection office.
Please pay attention to fire during installation, since organic solvent such as adhesive is used.
Please conduct sufficient ventilation when adhesive is used. Remove adhesive immediately in case it contacts to skin. Please see doctor if feel sick or unusual.
Some sealing material contains plasticizer (phthalate, DOP, etc.) or organic solvent (xylene, toluene) that may have negative effect on PVC pipe or fitting. Please do not use sealing material that contains those component.
Cable that contains plasticizer may have negative effect on pipe or fitting. Please avoid direct contact of those cables to pipe and fittings.
Please consut us in case there is some skeptical use but not specified in this.
Precautions to use
*Please note we cannot take responsibility for damage or accident in case
of use without following the instruction stated here.
Please follow the instruction and conduct safe and secured installation for Eslon AC Drain Pipe and Fittings.
Cautions
-
SEKISUI CHEMICAL CO.,LTD.
All rights reserved.
Urban Infrastructure & Environmental Products Company
Oct. 2013 First Edition
2014 .2. 0TH TX
Colors of the actual products may vary from the colors shown in this printed material.Information in this document is subject to change without notice.
Eslon AC Drain Pipe and FittingsCatalog
Urban Infrastructure & Environmental Products Company
http://www.eslontimes.com/en/