Accessible Pedestrian Signal (APS)€¦ · 20-03-2018  · APS Push Button Placement Push button...

44
Accessible Pedestrian Signal (APS) 2019

Transcript of Accessible Pedestrian Signal (APS)€¦ · 20-03-2018  · APS Push Button Placement Push button...

Page 1: Accessible Pedestrian Signal (APS)€¦ · 20-03-2018  · APS Push Button Placement Push button was placed on the grade break/edge of landing 6’ long ramp constructed 4’ New

Accessible Pedestrian Signal (APS)

2019

Page 2: Accessible Pedestrian Signal (APS)€¦ · 20-03-2018  · APS Push Button Placement Push button was placed on the grade break/edge of landing 6’ long ramp constructed 4’ New

•Sample APS Intersection Layout

2

Page 3: Accessible Pedestrian Signal (APS)€¦ · 20-03-2018  · APS Push Button Placement Push button was placed on the grade break/edge of landing 6’ long ramp constructed 4’ New

• Intersection Push Button Table

3

Page 4: Accessible Pedestrian Signal (APS)€¦ · 20-03-2018  · APS Push Button Placement Push button was placed on the grade break/edge of landing 6’ long ramp constructed 4’ New

4

Signal Control Points• PB8-2 and PB6-1

APS Signals Incorporated 2013

Page 5: Accessible Pedestrian Signal (APS)€¦ · 20-03-2018  · APS Push Button Placement Push button was placed on the grade break/edge of landing 6’ long ramp constructed 4’ New

• Additional plan information will provide construction more guidance.

Intersection Push Button Table

2’6.5’

5

Page 6: Accessible Pedestrian Signal (APS)€¦ · 20-03-2018  · APS Push Button Placement Push button was placed on the grade break/edge of landing 6’ long ramp constructed 4’ New

4’ long rampdesignedLanding

APS Push Button Placement

Push button was placed on the grade break/edge of

landing

6’ long rampconstructed

4’ New (X,Y)

6’

(X,Y)

(X,Y) Push button was placed in the middle of the

ramp/landing

• Additional plan information will minimize rework.• Verify Push Button/Pedestal staking matches plan

layout.

6

Page 7: Accessible Pedestrian Signal (APS)€¦ · 20-03-2018  · APS Push Button Placement Push button was placed on the grade break/edge of landing 6’ long ramp constructed 4’ New

7

ADA Preferred APS Design

• Push Button Offset from Grade Break¾ Minimum 0.75’¾ Preferred 2.0’

• Maintain a 6.0’ MAR0.75’

6.0’

Page 8: Accessible Pedestrian Signal (APS)€¦ · 20-03-2018  · APS Push Button Placement Push button was placed on the grade break/edge of landing 6’ long ramp constructed 4’ New

8

• Discontinued Push Button Station

Page 9: Accessible Pedestrian Signal (APS)€¦ · 20-03-2018  · APS Push Button Placement Push button was placed on the grade break/edge of landing 6’ long ramp constructed 4’ New

9

• Discontinued Push Button Station

Page 10: Accessible Pedestrian Signal (APS)€¦ · 20-03-2018  · APS Push Button Placement Push button was placed on the grade break/edge of landing 6’ long ramp constructed 4’ New

10

APS Push Button Station and Location

MUTCD

MnDOT

Page 11: Accessible Pedestrian Signal (APS)€¦ · 20-03-2018  · APS Push Button Placement Push button was placed on the grade break/edge of landing 6’ long ramp constructed 4’ New

11

New Breakaway Pedestal Base Push Button Station

APS Push Button Station

Page 12: Accessible Pedestrian Signal (APS)€¦ · 20-03-2018  · APS Push Button Placement Push button was placed on the grade break/edge of landing 6’ long ramp constructed 4’ New

12

Breakaway Base Push Button Station

APS Push Button Station

Page 13: Accessible Pedestrian Signal (APS)€¦ · 20-03-2018  · APS Push Button Placement Push button was placed on the grade break/edge of landing 6’ long ramp constructed 4’ New

13

APS Push Button Station Foundation

APS Push Button Station Details

Page 14: Accessible Pedestrian Signal (APS)€¦ · 20-03-2018  · APS Push Button Placement Push button was placed on the grade break/edge of landing 6’ long ramp constructed 4’ New

14

APS Push Button Station Foundation

APS Push Button Station Details

Page 15: Accessible Pedestrian Signal (APS)€¦ · 20-03-2018  · APS Push Button Placement Push button was placed on the grade break/edge of landing 6’ long ramp constructed 4’ New

15

APS Push Button Station Foundation

APS Push Button Station Details

Picture on the left Anchor Rods came out on impact making reinstallation difficult.Correct installation on the Pedestal Base on the right shows breakaway base working as designed.

Page 16: Accessible Pedestrian Signal (APS)€¦ · 20-03-2018  · APS Push Button Placement Push button was placed on the grade break/edge of landing 6’ long ramp constructed 4’ New

16

1” Rigid PVC Conduit with End Bell (2” +/- ½” Projection)

Anchor Rod Placement and Conduit

Page 17: Accessible Pedestrian Signal (APS)€¦ · 20-03-2018  · APS Push Button Placement Push button was placed on the grade break/edge of landing 6’ long ramp constructed 4’ New

17

APS Push Button Details

Page 18: Accessible Pedestrian Signal (APS)€¦ · 20-03-2018  · APS Push Button Placement Push button was placed on the grade break/edge of landing 6’ long ramp constructed 4’ New

18

Flare landing to provide 9” minimum for push button station foundation

APS Push Button Details

Page 19: Accessible Pedestrian Signal (APS)€¦ · 20-03-2018  · APS Push Button Placement Push button was placed on the grade break/edge of landing 6’ long ramp constructed 4’ New

19

Pedestrian Signs Installation • Sign must be made with retro reflective sheeting.• Verify Braille message plate is correct for button

location.

Page 20: Accessible Pedestrian Signal (APS)€¦ · 20-03-2018  · APS Push Button Placement Push button was placed on the grade break/edge of landing 6’ long ramp constructed 4’ New

Push buttons are improperly oriented

20

• Buttons at outside edge of crosswalks

• Typical APS Push Button Location

Page 21: Accessible Pedestrian Signal (APS)€¦ · 20-03-2018  · APS Push Button Placement Push button was placed on the grade break/edge of landing 6’ long ramp constructed 4’ New

21

• Typical APS Push Button Location

Push Button is oriented incorrectly

• Prosecution of Work (ADA) Push Button shall be located at the outside crosswalk edge

Page 22: Accessible Pedestrian Signal (APS)€¦ · 20-03-2018  · APS Push Button Placement Push button was placed on the grade break/edge of landing 6’ long ramp constructed 4’ New

22Original Design

• Typical APS Push Button Location

• Prosecution of Work (ADA) Push Button shall be located at the outside crosswalk edge

Page 23: Accessible Pedestrian Signal (APS)€¦ · 20-03-2018  · APS Push Button Placement Push button was placed on the grade break/edge of landing 6’ long ramp constructed 4’ New

23

• Typical APS Push Button Location

• Prosecution of Work (ADA) Push Button shall be located at the outside crosswalk edge

Page 24: Accessible Pedestrian Signal (APS)€¦ · 20-03-2018  · APS Push Button Placement Push button was placed on the grade break/edge of landing 6’ long ramp constructed 4’ New

24

1.5’ – 10’

• APS Push Button Details

5’ max.

BAC

K O

F C

UR

B

Page 25: Accessible Pedestrian Signal (APS)€¦ · 20-03-2018  · APS Push Button Placement Push button was placed on the grade break/edge of landing 6’ long ramp constructed 4’ New

25

6’ Min2’ Min

• APS Push Button Details

Page 26: Accessible Pedestrian Signal (APS)€¦ · 20-03-2018  · APS Push Button Placement Push button was placed on the grade break/edge of landing 6’ long ramp constructed 4’ New

26

MnDOT APS Pole Mounting Adaptor

Page 27: Accessible Pedestrian Signal (APS)€¦ · 20-03-2018  · APS Push Button Placement Push button was placed on the grade break/edge of landing 6’ long ramp constructed 4’ New

27

MnDOT APS Pole Mounting Adaptor

Special Provisions Prosecution of Work ADA “H”:

The push buttons shall be mounted at a height of 42 inches

Page 28: Accessible Pedestrian Signal (APS)€¦ · 20-03-2018  · APS Push Button Placement Push button was placed on the grade break/edge of landing 6’ long ramp constructed 4’ New

28

Push Button Orientation

Special Provisions Prosecution of Work ADA “H”:

Pedestrian push buttons shall be oriented with the button facing towards the intersection and the button face placed parallel to the outside edge of the crosswalk.

Incorrect

Correct

Page 29: Accessible Pedestrian Signal (APS)€¦ · 20-03-2018  · APS Push Button Placement Push button was placed on the grade break/edge of landing 6’ long ramp constructed 4’ New

29

42”

MnDOT APS Pole Mounting Adaptor

Page 30: Accessible Pedestrian Signal (APS)€¦ · 20-03-2018  · APS Push Button Placement Push button was placed on the grade break/edge of landing 6’ long ramp constructed 4’ New

30

• Pedestal Mount Detail

Page 31: Accessible Pedestrian Signal (APS)€¦ · 20-03-2018  · APS Push Button Placement Push button was placed on the grade break/edge of landing 6’ long ramp constructed 4’ New

31

“Saddle Adaptors” on Pedestals

2 ½”

Page 32: Accessible Pedestrian Signal (APS)€¦ · 20-03-2018  · APS Push Button Placement Push button was placed on the grade break/edge of landing 6’ long ramp constructed 4’ New

32

7/15/2015 Pedestal Foundation Detail

Pedestal Foundation Plate No. 8112I

Page 33: Accessible Pedestrian Signal (APS)€¦ · 20-03-2018  · APS Push Button Placement Push button was placed on the grade break/edge of landing 6’ long ramp constructed 4’ New

33

Special Provisions Prosecution of Work (ADA) “H” All Newly installed pedestal foundations when used as a push button station shall be constructed in accordance with applicable MnDOT Standard Plate 8112I. Concrete for new foundation shall be placed either with or after the landing concrete is placed….

MnDOT Pedestal Foundation

Top of the foundation surface shall be ¼”

max. higher than the top of landing surface.

Page 34: Accessible Pedestrian Signal (APS)€¦ · 20-03-2018  · APS Push Button Placement Push button was placed on the grade break/edge of landing 6’ long ramp constructed 4’ New

34

• 10” Horizontal Offset Exceeded

10” Max

Page 35: Accessible Pedestrian Signal (APS)€¦ · 20-03-2018  · APS Push Button Placement Push button was placed on the grade break/edge of landing 6’ long ramp constructed 4’ New

35

MnDOT Pedestal Foundation

Special Provisions Prosecution of Work (ADA) “H”

If a push button is placed on a new or previously existing pedestal pole, the push button shall be installed using 3 APS push button spacers (Saddle Adaptors) and the push button shall meet the vertical, horizontal, and crosswalk skew requirements.

Page 36: Accessible Pedestrian Signal (APS)€¦ · 20-03-2018  · APS Push Button Placement Push button was placed on the grade break/edge of landing 6’ long ramp constructed 4’ New

• Push Button Horizontal Offset

Pedestal foundations not flush with landings will leave you with approximately 10 ½” side reach or 8” with use of APS push button spacers.

Every effort should be made to minimize side reach distance

35

Page 37: Accessible Pedestrian Signal (APS)€¦ · 20-03-2018  · APS Push Button Placement Push button was placed on the grade break/edge of landing 6’ long ramp constructed 4’ New

37

Light Foundation in sidewalk

• This light foundation was placed in the PAR due to utility conflicts

4’ minimum PAR(not met)

Page 38: Accessible Pedestrian Signal (APS)€¦ · 20-03-2018  · APS Push Button Placement Push button was placed on the grade break/edge of landing 6’ long ramp constructed 4’ New

38

• Know the Proposed Ramp Design

Page 39: Accessible Pedestrian Signal (APS)€¦ · 20-03-2018  · APS Push Button Placement Push button was placed on the grade break/edge of landing 6’ long ramp constructed 4’ New

39

• Know the Proposed Ramp Design

0”

0”

Push button is in the middle of the landing because

the ramp isn’t directional

Page 40: Accessible Pedestrian Signal (APS)€¦ · 20-03-2018  · APS Push Button Placement Push button was placed on the grade break/edge of landing 6’ long ramp constructed 4’ New

40

Verify changes in design

• If you need to change the curb ramp design verify your push button layout will work .

0” 0”

Page 41: Accessible Pedestrian Signal (APS)€¦ · 20-03-2018  · APS Push Button Placement Push button was placed on the grade break/edge of landing 6’ long ramp constructed 4’ New

41

Push Button Location

• Do Push button locations pass the eye test from both directions?

Page 42: Accessible Pedestrian Signal (APS)€¦ · 20-03-2018  · APS Push Button Placement Push button was placed on the grade break/edge of landing 6’ long ramp constructed 4’ New

Button in middle of sidewalk

• This button was placed in the middle of the walk due to utility conflicts. And then removed and replaced to maintain a 6’ MAR.

6’

4’

42

Page 43: Accessible Pedestrian Signal (APS)€¦ · 20-03-2018  · APS Push Button Placement Push button was placed on the grade break/edge of landing 6’ long ramp constructed 4’ New

Rectangular Rapid Flashing Beacon

43

` Push Button needs to meet all APS requirements including locator tone and audible message◦ Audible message should say:

“Yellow lights are flashing.” Message should be spoken twice

◦ For RRFB’s, push buttons shall not use vibrotactile indications or percussive indications

◦ All push buttons on MnDOTROW need to be made accessible (not exclusive to RRFB’s)

` FHWA issued interim approval of RRFB effective 3/20/2018

(RRFB)

Page 44: Accessible Pedestrian Signal (APS)€¦ · 20-03-2018  · APS Push Button Placement Push button was placed on the grade break/edge of landing 6’ long ramp constructed 4’ New

ADA Training

Questions?

44