A/C SYSTEM SERVICE
1
A/C manifold gauge set Manifold valves Hose end
valves Performance
test Pressure
diagnosis Manifold
purging and disconnect
2
THE NATIONAL REFRIGERANT RECYCLING RULE WAS PROPOSED DECEMBER 10,1992 AND AN ...THE RECOVERY OR RECOVERY/RECYCLING EQUIPMENT MUST BE CERTIFIED BY AN APPROVED
3
A/C SYSTEM SERVICE
Recovery Evacuation Recharging Leak Check Freon Quality Robinair 347788
Demo
4
REFRIGERANT IDENTIFICATION
Follow equipment manufacturer’s instructions
Do not recover refrigerant with sealers
5
Section 609 Purity Standards (hand out)Refrigerant Purity Standards-handout.docx
Identify
REFRIGERANT PASS/FAILMUST BE 98% TO RECYCLE
6
A/C SEALANT DETECTOR MODEL
AC Sealant Detection7
REFRIGERANT RECOVERY
Connect recycler to vehicle service ports
Set machine to recover If recovery equipment
does not automatically shut off- recover until system drops into slight vacuum
Shut off valves and observe pressures for 5 minutes
If pressure increases-repeat recovery
8
THE FLOW DIAGRAM FOR A RECOVERY/ RECYCLING MACHINE SHOWING THE INTERNAL COMPONENTS AND THE PATH THAT REFRIGERANT TAKES DURING RECOVERY AND RECYCLING. (COURTESY OF ROBINAIR, SPX CORPORATION)
9
EVACUATION
Drain and measure system oil recovered in recycler
Evacuate system after leak check has been performed
If system has been exposed to moisture:
Evacuate until: 500 microns 29.2 in. 20-30 mins. minimum
Add amount of oil removed
10
RECHARGE
Determine system capacity Recharge system If recycler cannot fully charge
system (temp or pressure too high):
Shut off both manifold valves Start engine and turn on A/C
max Open doors/windows Charge remainder of refrigerant
through low side port without allowing pressure to exceed 50 psi
Close both valves and complete performance check
Disconnect hoses from vehicle
11
THE BUBBLES IN A SIGHT GLASS WILL DISAPPEAR AT A POINT LOWER THAN THE PROPER CHARGE AMOUNT. HIGH-SIDE PRESSURE WILL INCREASE AT A POINT THAT THE SYSTEM IS ALREADY OVERCHARGED. (COURTESY OF TOYOTA MOTOR SALES USA, INC.)