AC Measurement of Magnetic Susceptibility...4/10/2017 32 To calculate the permeability better to use...
Transcript of AC Measurement of Magnetic Susceptibility...4/10/2017 32 To calculate the permeability better to use...
![Page 1: AC Measurement of Magnetic Susceptibility...4/10/2017 32 To calculate the permeability better to use the template : \\engr-file-03\phyinst\APL Courses\PHYCS401\Common\Origin templates\AC](https://reader033.fdocuments.us/reader033/viewer/2022050600/5fa7584a65ad961bec127a22/html5/thumbnails/1.jpg)
AC Measurement of Magnetic Susceptibility
Physics 401, Spring 2017
Eugene V. Colla
![Page 2: AC Measurement of Magnetic Susceptibility...4/10/2017 32 To calculate the permeability better to use the template : \\engr-file-03\phyinst\APL Courses\PHYCS401\Common\Origin templates\AC](https://reader033.fdocuments.us/reader033/viewer/2022050600/5fa7584a65ad961bec127a22/html5/thumbnails/2.jpg)
Outline
• Ferromagnetism
• Measurement of the magnetic properties of
the materials
• Lab experimental setup and experiments
• Some results
4/10/2017 2
![Page 3: AC Measurement of Magnetic Susceptibility...4/10/2017 32 To calculate the permeability better to use the template : \\engr-file-03\phyinst\APL Courses\PHYCS401\Common\Origin templates\AC](https://reader033.fdocuments.us/reader033/viewer/2022050600/5fa7584a65ad961bec127a22/html5/thumbnails/3.jpg)
Ferromagnetism. Definition.
Some materials below a certain temperature (Tc) give rise to the magnetic field in absence of an applied field.
This magnetization is called spontaneous, the phenomenon – ferromagnetism and materials exhibiting this feature – ferromagnetics.
The main parameter of the ferromagnetic phase transition is spontaneous magnetization
0.0 0.5 1.00.0
0.5
1.0
T/Tc
Ms(T
)/M
s(0
)
Typical behavior of spontaneous magnetization as function of temperature
4/10/2017 3
![Page 4: AC Measurement of Magnetic Susceptibility...4/10/2017 32 To calculate the permeability better to use the template : \\engr-file-03\phyinst\APL Courses\PHYCS401\Common\Origin templates\AC](https://reader033.fdocuments.us/reader033/viewer/2022050600/5fa7584a65ad961bec127a22/html5/thumbnails/4.jpg)
Ferromagnetic materials.
Aleksandr Stoletov(1839 –1896)
Material Curie temp. (K)
Co 1388
Fe 1043
Fe2O3* 948
FeOFe2O3* 858
NiOFe2O3* 858
MgOFe2O3* 713
MnBi 630
Ni 627
MnSb 587
MnOFe2O3* 573
Y3Fe5O12* 560
CrO2 386
MnAs 318
Gd 292
“Stoletov” curve
4/10/2017 4
Stoletov performed pioneer works in area of ferromagnetic materials but better known by his research in photoelectric effect.
dM
dH
![Page 5: AC Measurement of Magnetic Susceptibility...4/10/2017 32 To calculate the permeability better to use the template : \\engr-file-03\phyinst\APL Courses\PHYCS401\Common\Origin templates\AC](https://reader033.fdocuments.us/reader033/viewer/2022050600/5fa7584a65ad961bec127a22/html5/thumbnails/5.jpg)
Domains. Hysteresis loop.
M~Ms
M=0
4/10/2017 5
* Courtesy Wikipedia
![Page 6: AC Measurement of Magnetic Susceptibility...4/10/2017 32 To calculate the permeability better to use the template : \\engr-file-03\phyinst\APL Courses\PHYCS401\Common\Origin templates\AC](https://reader033.fdocuments.us/reader033/viewer/2022050600/5fa7584a65ad961bec127a22/html5/thumbnails/6.jpg)
Kerr Effect. Visualization of the Domains
4/10/2017 6
John Kerr17 Dec 1824 – 15
Aug 1907
The Diagram of Typical Kerr Microscope
Courtesy of Radboud University, Nijmegen The Netherlands
![Page 7: AC Measurement of Magnetic Susceptibility...4/10/2017 32 To calculate the permeability better to use the template : \\engr-file-03\phyinst\APL Courses\PHYCS401\Common\Origin templates\AC](https://reader033.fdocuments.us/reader033/viewer/2022050600/5fa7584a65ad961bec127a22/html5/thumbnails/7.jpg)
Domains
Several grains of NdFeB with magnetic domainsmade visible via contrast with a Kerr microscope.
Courtesy of Wikipedia
Kerr microscopeCourtesy of University of Uppsala (Sweden)
4/10/2017 7
![Page 8: AC Measurement of Magnetic Susceptibility...4/10/2017 32 To calculate the permeability better to use the template : \\engr-file-03\phyinst\APL Courses\PHYCS401\Common\Origin templates\AC](https://reader033.fdocuments.us/reader033/viewer/2022050600/5fa7584a65ad961bec127a22/html5/thumbnails/8.jpg)
Domains
Courtesy of Wikipedia
4/10/2017 8
Moving domain walls in a grain of silicon steel caused by an increasing external magnetic field
![Page 9: AC Measurement of Magnetic Susceptibility...4/10/2017 32 To calculate the permeability better to use the template : \\engr-file-03\phyinst\APL Courses\PHYCS401\Common\Origin templates\AC](https://reader033.fdocuments.us/reader033/viewer/2022050600/5fa7584a65ad961bec127a22/html5/thumbnails/9.jpg)
Hysteresis Loops. Remagnetization loses
𝑾 = 𝑽න𝑯𝒅𝑩 𝑾𝒍𝒐𝒐𝒑 = 𝑽ׯ𝑯𝒅𝑩=V*Loop_area
Energy of the magnetic field
By cycling around the loop
4/10/2017 9
![Page 10: AC Measurement of Magnetic Susceptibility...4/10/2017 32 To calculate the permeability better to use the template : \\engr-file-03\phyinst\APL Courses\PHYCS401\Common\Origin templates\AC](https://reader033.fdocuments.us/reader033/viewer/2022050600/5fa7584a65ad961bec127a22/html5/thumbnails/10.jpg)
“Hard” materials. Application.RAM memory
Hard drives, floppy, magnetic tape
Permanent magnets
4/10/2017 10
![Page 11: AC Measurement of Magnetic Susceptibility...4/10/2017 32 To calculate the permeability better to use the template : \\engr-file-03\phyinst\APL Courses\PHYCS401\Common\Origin templates\AC](https://reader033.fdocuments.us/reader033/viewer/2022050600/5fa7584a65ad961bec127a22/html5/thumbnails/11.jpg)
“Soft” materials. Application.
Power transformers
Chokes, inductors
4/10/2017 11
![Page 12: AC Measurement of Magnetic Susceptibility...4/10/2017 32 To calculate the permeability better to use the template : \\engr-file-03\phyinst\APL Courses\PHYCS401\Common\Origin templates\AC](https://reader033.fdocuments.us/reader033/viewer/2022050600/5fa7584a65ad961bec127a22/html5/thumbnails/12.jpg)
4/10/2017 12
Magnetic Field, Susceptibility etc.
0B H M
B – magnetic inductionM – magnetization, in general M(H)
M Hχ – magnetic susceptibility, in general χ(H)
0 01
rB H H H
0
0
1;
r r
dB dB
dH dH
1r
![Page 13: AC Measurement of Magnetic Susceptibility...4/10/2017 32 To calculate the permeability better to use the template : \\engr-file-03\phyinst\APL Courses\PHYCS401\Common\Origin templates\AC](https://reader033.fdocuments.us/reader033/viewer/2022050600/5fa7584a65ad961bec127a22/html5/thumbnails/13.jpg)
Modulation Spectroscopy
4/10/2017 13
( )B f H
0 1H = H + H sinωt
H0
0 1H = H + H sinωt
0 1
dfB = f(H ) + (H sinωt)+ ...
dH
B0Bw
( )B f H
H1=const
𝑩𝝎~𝒅𝑩
𝒅𝑯
![Page 14: AC Measurement of Magnetic Susceptibility...4/10/2017 32 To calculate the permeability better to use the template : \\engr-file-03\phyinst\APL Courses\PHYCS401\Common\Origin templates\AC](https://reader033.fdocuments.us/reader033/viewer/2022050600/5fa7584a65ad961bec127a22/html5/thumbnails/14.jpg)
Measuring the magnetic permeability
0
0 0 0
,
( , ) (1 ( , ))H
dBH H
dH w
w w
By applying a small modulation of the H
field we can measure the derivative of the
B-H hysteresis loop or dependence of the
magnetic permeability on H field
4/10/2017 14
![Page 15: AC Measurement of Magnetic Susceptibility...4/10/2017 32 To calculate the permeability better to use the template : \\engr-file-03\phyinst\APL Courses\PHYCS401\Common\Origin templates\AC](https://reader033.fdocuments.us/reader033/viewer/2022050600/5fa7584a65ad961bec127a22/html5/thumbnails/15.jpg)
Setup #1. Investigation of the hysteresis loops.
4/10/2017 15
![Page 16: AC Measurement of Magnetic Susceptibility...4/10/2017 32 To calculate the permeability better to use the template : \\engr-file-03\phyinst\APL Courses\PHYCS401\Common\Origin templates\AC](https://reader033.fdocuments.us/reader033/viewer/2022050600/5fa7584a65ad961bec127a22/html5/thumbnails/16.jpg)
Setup #1. Investigation of the hysteresis loops.
4/10/2017 16
0 1 cosH H H tw
𝑯 =𝑵𝒑𝑰𝒑
𝟐𝝅𝒓
![Page 17: AC Measurement of Magnetic Susceptibility...4/10/2017 32 To calculate the permeability better to use the template : \\engr-file-03\phyinst\APL Courses\PHYCS401\Common\Origin templates\AC](https://reader033.fdocuments.us/reader033/viewer/2022050600/5fa7584a65ad961bec127a22/html5/thumbnails/17.jpg)
Major/minor loops. Demagnetization
B
H
saturation
80 160 240
-100
0
100
time
H(a
.u.)
Waveform of H-field
4/10/2017 17
![Page 18: AC Measurement of Magnetic Susceptibility...4/10/2017 32 To calculate the permeability better to use the template : \\engr-file-03\phyinst\APL Courses\PHYCS401\Common\Origin templates\AC](https://reader033.fdocuments.us/reader033/viewer/2022050600/5fa7584a65ad961bec127a22/html5/thumbnails/18.jpg)
Demagnetization
0
20
40
60- 2
- 1
0
1
2
-3.6
-1.8
0.0
1.8
3.6
B (
a.u
.)
Idc (A)
time (m
in)
0 20 40 60
-2
-1
0
1
2
I DC (
A)
time (min)
Demagnetization of 4C65 toroid from Ferroxcube
4/10/2017 18
![Page 19: AC Measurement of Magnetic Susceptibility...4/10/2017 32 To calculate the permeability better to use the template : \\engr-file-03\phyinst\APL Courses\PHYCS401\Common\Origin templates\AC](https://reader033.fdocuments.us/reader033/viewer/2022050600/5fa7584a65ad961bec127a22/html5/thumbnails/19.jpg)
Hysteresis Loops
Fig. A family of AC hysteresis loops for grain-oriented electrical steel (BR denotes
remanence andHC is the coercivity). Courtesy Zureks (Wikipedia)
4/10/2017 19
![Page 20: AC Measurement of Magnetic Susceptibility...4/10/2017 32 To calculate the permeability better to use the template : \\engr-file-03\phyinst\APL Courses\PHYCS401\Common\Origin templates\AC](https://reader033.fdocuments.us/reader033/viewer/2022050600/5fa7584a65ad961bec127a22/html5/thumbnails/20.jpg)
Measuring the magnetic permeability
-200 -100 0 100 2000
2
4
6
8
10
12
14
'/1
000
H (A/m)
max
~12700
-10 0 10
8
10
12
H (A/m)
0 500 1000-4
-2
0
2
4
I DC (
A)
time (s)
DC current profile and magneticpermeability of MagneticsZW44715TC
4/10/2017 20
![Page 21: AC Measurement of Magnetic Susceptibility...4/10/2017 32 To calculate the permeability better to use the template : \\engr-file-03\phyinst\APL Courses\PHYCS401\Common\Origin templates\AC](https://reader033.fdocuments.us/reader033/viewer/2022050600/5fa7584a65ad961bec127a22/html5/thumbnails/21.jpg)
From permeability to B-H hysteresis loop
Step#1. Performing one fast IDC scan the based on the result preparing the “smart” IDC profile
ECE storeroom unknown material Sample #5
0 200 400 600 800
-1
0
1
I DC (A
)
time (s)
Step#2. Performing precise scan the. Plotting raw data based
-1.0 -0.5 0.0 0.5 1.00.0
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
Y (
mV
)
IDC (A)
Voltage units measured by SR830
Current in primary coil in A
4/10/2017 21
![Page 22: AC Measurement of Magnetic Susceptibility...4/10/2017 32 To calculate the permeability better to use the template : \\engr-file-03\phyinst\APL Courses\PHYCS401\Common\Origin templates\AC](https://reader033.fdocuments.us/reader033/viewer/2022050600/5fa7584a65ad961bec127a22/html5/thumbnails/22.jpg)
From permeability to B-H hysteresis loop
Step#3. What we are measuring? Calibration.
Lock-in measures emf on the pickup coil
;lock in
dV B S
dt
Here Ip is ac current in primary coil L3; 𝑰𝒑 =𝑽𝟎𝐬𝐢𝐧(𝝎𝒕)
𝑹𝟐
4/10/2017 22
![Page 23: AC Measurement of Magnetic Susceptibility...4/10/2017 32 To calculate the permeability better to use the template : \\engr-file-03\phyinst\APL Courses\PHYCS401\Common\Origin templates\AC](https://reader033.fdocuments.us/reader033/viewer/2022050600/5fa7584a65ad961bec127a22/html5/thumbnails/23.jpg)
From permeability to B-H hysteresis loop
Step#3. What we are measuring? Calibration.
Primary coil of Np turns supplied by current Ip creates magnetic field H and flux dΦ
For toroid: 𝑯 =𝑵𝒑𝑰𝒑
𝟐𝝅𝒓R2 <r < R1
2
1
2
1
ln
2 2
R
R
RI N t dr I N td H da
r R
da=dr*t
4/10/2017 23
![Page 24: AC Measurement of Magnetic Susceptibility...4/10/2017 32 To calculate the permeability better to use the template : \\engr-file-03\phyinst\APL Courses\PHYCS401\Common\Origin templates\AC](https://reader033.fdocuments.us/reader033/viewer/2022050600/5fa7584a65ad961bec127a22/html5/thumbnails/24.jpg)
From permeability to B-H hysteresis loop
Step#3. What we are measuring? Calibration.
2
1
ln2
pickup p p
pickup
N N I t RN d
R
Total flux detected by pickup coil:
Inductance of the toroid:
0 0; ( )
rL L L i L
I
0 20
1
ln2
pickup pN N t RL
R
Np and Ip number of turns of AC primary coil and AC rms current
4/10/2017 24
![Page 25: AC Measurement of Magnetic Susceptibility...4/10/2017 32 To calculate the permeability better to use the template : \\engr-file-03\phyinst\APL Courses\PHYCS401\Common\Origin templates\AC](https://reader033.fdocuments.us/reader033/viewer/2022050600/5fa7584a65ad961bec127a22/html5/thumbnails/25.jpg)
From permeability to B-H hysteresis loop
-1.0 -0.5 0.0 0.5 1.00.0
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
Y (
mV
)
IDC (A)
𝑯𝟎 =𝑵𝒑𝑰𝑫𝑪
𝟐𝝅𝒓
0
p
lock in r
dIV L
dt
-400 -200 0 200 4000
1000
2000
3000
4000
5000
6000
'
H (A/m)
4/10/2017 25
![Page 26: AC Measurement of Magnetic Susceptibility...4/10/2017 32 To calculate the permeability better to use the template : \\engr-file-03\phyinst\APL Courses\PHYCS401\Common\Origin templates\AC](https://reader033.fdocuments.us/reader033/viewer/2022050600/5fa7584a65ad961bec127a22/html5/thumbnails/26.jpg)
From permeability to B-H hysteresis loop
0 0 0 0( ) ( )
r
dBH H H
dH
Step#4. From r(H) to B-H
After integrating →
-400 -200 0 200 4000
1000
2000
3000
4000
5000
6000
'
H (A/m)
-400 -200 0 200 400
-0.2
0.0
0.2
B(T
)
H (A/m)
0( ) ( )
rB H H dH
4/10/2017 26
![Page 27: AC Measurement of Magnetic Susceptibility...4/10/2017 32 To calculate the permeability better to use the template : \\engr-file-03\phyinst\APL Courses\PHYCS401\Common\Origin templates\AC](https://reader033.fdocuments.us/reader033/viewer/2022050600/5fa7584a65ad961bec127a22/html5/thumbnails/27.jpg)
Software issue
4/10/2017 27
Icon on the desktop
1st week experiment
2nd week experiment
Demagnetization
B-H measurement
Preparation of the profile of the experiment
![Page 28: AC Measurement of Magnetic Susceptibility...4/10/2017 32 To calculate the permeability better to use the template : \\engr-file-03\phyinst\APL Courses\PHYCS401\Common\Origin templates\AC](https://reader033.fdocuments.us/reader033/viewer/2022050600/5fa7584a65ad961bec127a22/html5/thumbnails/28.jpg)
Software issueMeasuring profile preparation. Using profile template
Open a new file
Create a new file
Save prepared file for future use
![Page 29: AC Measurement of Magnetic Susceptibility...4/10/2017 32 To calculate the permeability better to use the template : \\engr-file-03\phyinst\APL Courses\PHYCS401\Common\Origin templates\AC](https://reader033.fdocuments.us/reader033/viewer/2022050600/5fa7584a65ad961bec127a22/html5/thumbnails/29.jpg)
Software issueMeasuring profile preparation. Using profile template.
![Page 30: AC Measurement of Magnetic Susceptibility...4/10/2017 32 To calculate the permeability better to use the template : \\engr-file-03\phyinst\APL Courses\PHYCS401\Common\Origin templates\AC](https://reader033.fdocuments.us/reader033/viewer/2022050600/5fa7584a65ad961bec127a22/html5/thumbnails/30.jpg)
Software issue
Measuring profile preparation
Example of simple protocol
Advanced profile
-400 -200 0 200 4000
1000
2000
3000
4000
5000
6000
'
H (A/m)
![Page 31: AC Measurement of Magnetic Susceptibility...4/10/2017 32 To calculate the permeability better to use the template : \\engr-file-03\phyinst\APL Courses\PHYCS401\Common\Origin templates\AC](https://reader033.fdocuments.us/reader033/viewer/2022050600/5fa7584a65ad961bec127a22/html5/thumbnails/31.jpg)
Software issueMeasurement Window
Lock-in amplifier response
The profile of the appliedDC current
Structure of the data file (B-H experiment)
![Page 32: AC Measurement of Magnetic Susceptibility...4/10/2017 32 To calculate the permeability better to use the template : \\engr-file-03\phyinst\APL Courses\PHYCS401\Common\Origin templates\AC](https://reader033.fdocuments.us/reader033/viewer/2022050600/5fa7584a65ad961bec127a22/html5/thumbnails/32.jpg)
Data analysis using Origin
4/10/2017 32
To calculate the permeability better to use the template :
\\engr-file-03\phyinst\APL Courses\PHYCS401\Common\Origin templates\AC magnetic Lab\MU_CALCULATION.otw
Raw dataParameters Calculated results
It does not contain the equations – you have to write them
![Page 33: AC Measurement of Magnetic Susceptibility...4/10/2017 32 To calculate the permeability better to use the template : \\engr-file-03\phyinst\APL Courses\PHYCS401\Common\Origin templates\AC](https://reader033.fdocuments.us/reader033/viewer/2022050600/5fa7584a65ad961bec127a22/html5/thumbnails/33.jpg)
Data analysis using Origin. Integrating.
0( ) ( )
rB H H dH
4/10/2017 33
![Page 34: AC Measurement of Magnetic Susceptibility...4/10/2017 32 To calculate the permeability better to use the template : \\engr-file-03\phyinst\APL Courses\PHYCS401\Common\Origin templates\AC](https://reader033.fdocuments.us/reader033/viewer/2022050600/5fa7584a65ad961bec127a22/html5/thumbnails/34.jpg)
Data analysis using Origin. Integrating.
0( ) ( )
rB H H dH offset
4/10/2017 34
Ms
-Ms
![Page 35: AC Measurement of Magnetic Susceptibility...4/10/2017 32 To calculate the permeability better to use the template : \\engr-file-03\phyinst\APL Courses\PHYCS401\Common\Origin templates\AC](https://reader033.fdocuments.us/reader033/viewer/2022050600/5fa7584a65ad961bec127a22/html5/thumbnails/35.jpg)
References
• Information about magnetic materials can be found in :
\\engr-file-03\phyinst\APL
Courses\PHYCS401\Experiments\AC_Magnetization\Magnetic
Materials
• SR830 manual: \\engr-file-03\phyinst\APL
Courses\PHYCS401\Common\EquipmentManuals\SR830m.pdf
4/10/2017 35