About us - HANSEATIC SOLUTIONS · G40 Series GRP Terminal 45 Enclosures Atex directive In 2003 the...

51
About us.... Petrel Limited, a division of Chamberlin plc., manufacturers of lighting and control equipment for potentially explosive atmospheres. Headquartered at our manufacturing operation in Birmingham UK, Petrel Limited continues to maintain a long tradition of high quality product design, development and production under a strict quality management regime to improve the overall sales and service package. Capitalising on decades of design, technical and manufacturing expertise Petrel continues to produce innovative Ex products for lighting and control applications around the world. Continual investment in product development and manufacturing techniques ensures state of the art Ex products of consistent high quality, are produced in an ISO 9000-2000 quality assured environment. Accredited third party bodies ensure our ATEX certified products give the performance you need in those difficult hazardous areas. By supporting our major clients in the UK and through our network of international partners we maintain significant global reach and presence. Looking after our customers first means we also look after ourselves and the proof of our success is in our continuing double digit growth. Peter Maclean Managing Director Page 1

Transcript of About us - HANSEATIC SOLUTIONS · G40 Series GRP Terminal 45 Enclosures Atex directive In 2003 the...

Page 1: About us - HANSEATIC SOLUTIONS · G40 Series GRP Terminal 45 Enclosures Atex directive In 2003 the Atex Directive becomes a mandatory requirement for all hazardous area equipment

About us....Petrel Limited, a division of Chamberlin plc., manufacturers of lighting and control equipment forpotentially explosive atmospheres.

Headquartered at our manufacturing operation inBirmingham UK, Petrel Limited continues to maintain along tradition of high quality product design, development and production under a strict quality management regime to improve the overall sales and service package.

Capitalising on decades of design, technical and manufacturing expertise Petrel continues to produceinnovative Ex products for lighting and control applicationsaround the world. Continual investment in product development and manufacturing techniques ensures stateof the art Ex products of consistent high quality, are produced in an ISO 9000-2000 quality assured environment. Accredited third party bodies ensure ourATEX certified products give the performance you need inthose difficult hazardous areas.

By supporting our major clients in the UK and through ournetwork of international partners we maintain significant globalreach and presence. Looking after our customers first means wealso look after ourselves and the proof of our success is in our continuing doubledigit growth.

Peter MacleanManaging Director

Page 1

Page 2: About us - HANSEATIC SOLUTIONS · G40 Series GRP Terminal 45 Enclosures Atex directive In 2003 the Atex Directive becomes a mandatory requirement for all hazardous area equipment

Contents

Page 2

Petrel Guide to 4Hazardous Areas

Types of Protection 5

Hazardous Areas Products 6

PAGE

7 Series EEx dEmergency Fluorescent 20 Luminaire

7 Series EEx dCompact Fluorescent 22Luminaire

8 Series EEx deAdjustable angle 24Flood Light range

9 Series Standard and Emergency 26 Fluorescent Luminaire

9R Series EEx edStandard and Emergency 28Recessed Fluorescent Luminaire

EXENStandard and Emergency 30Fluorescent Luminaire

DN Series Bulk head 34Luminaire

ZT Adjustable Angle Flood 36Light Range

DB Series General Industrial Bulk head 38Luminaire

457 Submersible Bulkhead 32Luminaire

7 Series EEx dStandard Fluorescent 18Luminaire

6 Series EEx de621 Bulkhead 16Range

6 Series EEx de620 Well Glass 14Range

6 Series EEx de610 Well 12Glass Range

6 Series EEx de610 Beacon / 10Warning Light

6 Series EEx deQL Fit and Forget 8Well Glass

Hazardous Subdivisions 7

PAGE

Page 3: About us - HANSEATIC SOLUTIONS · G40 Series GRP Terminal 45 Enclosures Atex directive In 2003 the Atex Directive becomes a mandatory requirement for all hazardous area equipment

Page 3

Contents

G20 Series Motor Starters 40and Isolators

PAGE PAGE

Spares and Accessories 47E

Lamp Tables and 'T' Ratings for Ambient 50 Temperatures

G2 Range of Cast Enclosures and Custom Built 43Control Panels

G40 SeriesGRP Terminal 45Enclosures

Page 4: About us - HANSEATIC SOLUTIONS · G40 Series GRP Terminal 45 Enclosures Atex directive In 2003 the Atex Directive becomes a mandatory requirement for all hazardous area equipment

Atex directive

In 2003 the Atex Directive becomes a mandatory requirement for all hazardous area equipment sold in the European Unionand equipment must have applicable Atex certificates.

In addition to the technical requirements demanded by the appropriate standards for each type of protection concept, theAtex Directive imposes additional requirements on the certificate holder in terms of quality system, product documentation,installation information, possible limitations of use in the relation to its intended environment, labelling information etc.

The technical details of gas Grouping and Temperature Classification are unalteredbut zoning references are amended and gas, vapour, mist and dust categories arecombined under a single classification as shown opposite.

The marking of the equipment shall include the following typical data:

Ex II 2 G Where II is the gas group;2 is the category for use(prev. zone)G (or D) is the type of explosive atmosphere - G = gas, vapour or mist; and D = Dust

IIC T4 Ta = -200C to + 550C Where the T class will vary against ambient IIC T5 Ta = -200C to + 250C The T class marking for dust may also be shown if different to gas

Page 4

Ingress protection

In addition to protection against the risk of explosion or ignition luminaires for use in hazardous areas will also need toprovide adequate protection against the ingress of solids or liquids. The degree of classification is denoted by the IPclassification system.

A two digit number is used to identify the degree of protection.

The first digit of the code denotes protection against The second digit denotes protection against moisturedust and solid objects

IP0X No protection against solids IPX0 No special protectionIP1X Protections against large solids (50mmØ) IPX1 Drip proof (vertical falling parts)IP2X Protections against medium solids (12mmØ) IPX3 Rain proof (rain up to angles of 600)IP3X No entry of a 2.5mmØ probe to live parts IPX4 Splash proof (spray from any angle)IP4X No entry of a 1mmØ probe to live parts IPX5 Water jet proofIP5X Dust proof (no dust deposit around live parts) IPX7 Temporary immersion in waterIP6X Dust tight (no dust entry) IPX8 Submersion in declared depth

Terminal AlexZone 0 & 20 Category 1Zone 1 & 21 Category 2Zone 2 & 22 Category 3

Petrel Guide to Hazardous Areas

Page 5: About us - HANSEATIC SOLUTIONS · G40 Series GRP Terminal 45 Enclosures Atex directive In 2003 the Atex Directive becomes a mandatory requirement for all hazardous area equipment

Types of Protection

Page 5

There are established engineering concepts recognised by the IEC for the design of electrical equipment for hazardous areaapplications. These engineering concepts are the basis of protection against the risk of fire or explosion.Each concept is identified by a protection symbol. The prefix ’Ex'’ in the symbol denotes a national standard whilst ‘EEx’denotes a harmonised European standard. This European standard has a ‘EN’ prefix.

If a design relies on more than one concept all symbols are normally shown.

Symbol & EN ref Concept Summary Zone use Atex Category

EEx ia EN/IEC 60079-11 Intrinsic safety Limits energy of sparks & surface temperatures 0 2 & 3(using electronics c/w 2 failure protection devices)

EExib EN/IEC 60079-11 Intrinsic safety Limits energy of sparks & surface temperatures 1 & 2 2 & 3(using electronics c/w 1 failure protection devices)

EEx d EN/IEC 60079-1 Flameproof Contains explosion quenches flame 1 & 2 2 & 3

EEx e EEN/IEC 60079-7 Increased safety No arcs, sparks or hot surfaces 1 & 2 2 & 3

EEx p EN/IEC 60079-2 Pressurised Keeps flammable gas out 1 & 2 2 & 3

EEx m EN/IEC 60079-18 Encapsulated Keeps flammable gas out 1 & 2 2 & 3

EEx q EN/IEC 60079-5 Powder filled Keeps flammable gas out 1 & 2 2 & 3

EEx o EN/IEC 60079-6 Oil filled Keeps hazard away from ignition source using 1 & 2 2 & 3inert oil

EEx N EN/IEC 60079-15 Non-sparking No arcs, sparks or hot surfaces 2 3

Emergency products

EN-60 598 2.22

This harmonised European product standard sets out the requirements for materials, design, manufacture, testing andoperation of emergency lighting luminaires and equipment.

All emergency luminaires comply with EN 60 598 2.22 when used in an ambient temperature range of between 0 and+250C. For any deviations please contact your local Technical Department.

Page 6: About us - HANSEATIC SOLUTIONS · G40 Series GRP Terminal 45 Enclosures Atex directive In 2003 the Atex Directive becomes a mandatory requirement for all hazardous area equipment

Page 6

Petrel Guide to Hazardous Areas

Temperature classification

The temperature classification of a given gas is the temperature above which an appropriate mixture of that gas with airwill ignite. it is critical that the maximum surface temperature of any part of the equipment which may come into contactwith the gas/air mixture, does not exceed the ignition temperature of the mixture.

The temperature class or ‘T rating’ is normally based on an ambient temperature of -200C to +400C

Class Surface Temperature 0C Ignition Temperature 0CT Rating Max permitted Gas/air mixture

T1 450 >450T2 300 >300T3 200 >200T4 135 >135T5 100 >100T6 85 >85

Gas Groups

The explosive gases, vapours, and mists present in the atmosphere aregrouped into temperature classes and gas groups according to variousproperties such as ignition temperature, the energy required to ignite themixture, the energy produced by an explosion, flame transmissioncapability etc.

Group I Electrical equipment for use underground in mines susceptible tothe hazard of firedamp (methane)

Group II Electrical equipment for use in all other hazardous areas. Thisgroup is then subdivided into the following 3 further groups according tothe maximum experimental safety gap for non-transmission of an internalignition plus the minimum ignition current of the mixture.

Hazardous Area products from Petrel

Page 7: About us - HANSEATIC SOLUTIONS · G40 Series GRP Terminal 45 Enclosures Atex directive In 2003 the Atex Directive becomes a mandatory requirement for all hazardous area equipment

Page 7

HazardousSubdivisions

Page 8: About us - HANSEATIC SOLUTIONS · G40 Series GRP Terminal 45 Enclosures Atex directive In 2003 the Atex Directive becomes a mandatory requirement for all hazardous area equipment

Certification and Approval

Certification Code EEx de II 2 GD IIC T5Certification number SIRA 00 ATEX 1047Certification standard EN 60079-0, 1, 7Protection IP 66

Features

Up to 100,000 hours life expectancyOptional internal and/or external ReflectorImmediate ignition and re-ignition Fixed or directional mounting optionsIntegral EEx e Terminal chamber

Options

Sealed and flying lead fittedOptional internal /external ReflectorColoured glass optionFixed or directional mounting options

Terminal Block Access Swivel Stirrup mounting Threaded flame path

Page 8

6 Series EEx deQL Fit and Forget Well Glass

ATEXCERTIFIED

CAT 11ZONE 1

Page 9: About us - HANSEATIC SOLUTIONS · G40 Series GRP Terminal 45 Enclosures Atex directive In 2003 the Atex Directive becomes a mandatory requirement for all hazardous area equipment

Technical Data

Page 9

6 Series EEx deQL Fit and Forget Well Glass

ATEXCERTIFIED

CAT 11ZONE 1

Supply Voltage 220-240v, 50/60Hz

Operating Temperature -25ºC to +40 ºC

Control Gear High frequency generator driving induction lampwithin the luminaire

Lamp Options 55w or 85w induction lamp

Cable Entries 2 x M20 – ISO (1 plugged) as StandardOther threads available.

Terminals 4 (4mm) wire and earth with looping facilityCable crimping required at installation when looping

Mounting Facility Back mounted fixing strap

Access Terminals accessed via terminal cover retained by cap screwsLamp and gear accessed via removable glass dome

Material Corrosion resistant marine grade aluminium body and bezelToughened Borosilicate glass dome

Finish 2 Pack epoxy paint on primed surface.Standard colour - AquaAdditional costs for non standard colours

Accessories Internal or external reflector Pivot bracket for directional controlPendant mountWire Guard

Weight 15.0Kgs

Features Ultra long lifeFlicker free startLow energy consumptionConstant light independent of voltage fluctuations Automatic safety cut out in case of lamp failure

Page 10: About us - HANSEATIC SOLUTIONS · G40 Series GRP Terminal 45 Enclosures Atex directive In 2003 the Atex Directive becomes a mandatory requirement for all hazardous area equipment

Certification and Approval

Certification Code EEx de II 2 GD IIC T3 and 4 (See lamp tables for T rating)Certification number SIRA 00 ATEX 1048Certification standard EN 60079-0, 1,7Protection IP 66

Features

Rotating BeaconXenon flashing unitIIC as standardHeavy Duty constructionIntegral EEx e terminal chamberFOR AMBIENT TEMPERATURE “T” RATINGS SEE TABLES AT REAR OF CATALOGUE

Options

Range of fresnel colours or glass colouringLong Life LED optionsRange of warning and flash optionsHigh ambient version

Xenon Flash with Freznel LED cluster Terminal block housing

Page 10

6 Series EEx de610 Beacon / Warning Light

ATEXCERTIFIED

CAT 11ZONE 1

Page 11: About us - HANSEATIC SOLUTIONS · G40 Series GRP Terminal 45 Enclosures Atex directive In 2003 the Atex Directive becomes a mandatory requirement for all hazardous area equipment

Technical Data

Page 11

6 Series EEx de610 Beacon / Warning Light

ATEXCERTIFIED

CAT 11ZONE 1

Supply Voltage Beacons 240vWarning Lights AC – 24 to 277 50/60Hz DC also

Operating Temperature -45ºC to +70 ºC

Control Gear (when Fitted) Electronic flasher unitRotating Reflector drive

Lamp Options Beacons: 150w GLS max (ES, E27 or BC)25w SL (ES, E27 or BC), 20w PLCERotating 55w of 70w (supplied)

Cable Entries 2 x M20 – ISO (1 plugged) as StandardOther threads available.

Terminals 4 (4mm) wire and earth with looping facilityCable crimping required at installation when looping

Mounting Facility Back mounted fixing strap

Access Terminals accessed via terminal cover retained by cap screwsLamp and gear accessed via removable glass dome

Material Corrosion resistant marine grade aluminium body and bezelToughened Borosilicate glass dome

Finish 2 Pack epoxy paint on primed surface.Standard colour - AquaAdditional costs for non standard colours

Accessories Internal or external reflector Pivot bracket for directional controlPendant mountWire GuardGlass colouring available

Weight 9.0Kgs

Features Flashing Xenon – Output 195,000CD peak ORRotating Reflector beacon.70ºC ambient option availableIIC as standardHeavy Duty Construction

Page 12: About us - HANSEATIC SOLUTIONS · G40 Series GRP Terminal 45 Enclosures Atex directive In 2003 the Atex Directive becomes a mandatory requirement for all hazardous area equipment

Certification and Approval

Certification Code EEx de II 2 GD IIC T3 and 4 (See lamp tables for T rating)Certification number SIRA 00 ATEX 1048Certification standard EN 60079-0, 1, 7Protection IP 66

Features

Range of lamp sources availableIIC as standardHeavy duty constructionIntegral EEx e Terminal chamber

FOR AMBIENT TEMPERATURE “T” RATINGS SEE TABLES AT REAR OF CATALOGUE

Options

Range of lamp sourcesLow and high temperature versionsInternal and external reflectors Coloured glass range

610 Threaded flame path Terminal block access 610 blue lens

Page 12

6 Series EEx de610 Well Glass Range

ATEXCERTIFIED

CAT 11ZONE 1

Page 13: About us - HANSEATIC SOLUTIONS · G40 Series GRP Terminal 45 Enclosures Atex directive In 2003 the Atex Directive becomes a mandatory requirement for all hazardous area equipment

Technical Data

Page 13

6 Series EEx de610 Well Glass Range

ATEXCERTIFIED

CAT 11ZONE 1

Supply Voltage 240v 50HzCheck for alternative voltages

Operating Temperature -45ºC to +70 ºC

Control Gear (when Fitted) Ballast, ignitor and capacitor can be fitted within the luminaire

Lamp Options Certified with elliptical lamps (Lamps not provided)50w, 70w, 110w SON-E and 70w SON-R50w, 80w ,125w HPMV/MBF25w SL or 20w PLCE150w GLS with ES (E27) lamp holder. BC holder also available

Cable Entries 2 x M20 – ISO (1 plugged) as StandardOther threads available.

Terminals 4 (4mm) wire and earth with looping facilityCable crimping required at installation when looping

Mounting Facility Back mounted fixing strap

Access Terminals accessed via terminal cover retained by cap screwsLamp and gear accessed via removable glass dome

Material Corrosion resistant marine grade aluminium body and bezelToughened Borosilicate glass dome

Finish 2 Pack epoxy paint on primed surface.Standard colour - AquaAdditional costs for non standard colours

Accessories Internal or external reflector Pivot bracket for directional controlPendant mountWire Guard

Weight 9kg to 12kgslamp dependant

Features 70ºC ambient option availableIIC as standardHeavy duty construction

Page 14: About us - HANSEATIC SOLUTIONS · G40 Series GRP Terminal 45 Enclosures Atex directive In 2003 the Atex Directive becomes a mandatory requirement for all hazardous area equipment

Certification and Approval

Certification Code EEx de II 2 GD IIC T2 – T6 (See lamp tables for T rating)Certification number SIRA 00 ATEX 1047Certification standard EN 60079-0, 1, 7Protection IP 66

Features

Large lamp option rangeHigh Ambient options availableRapid re lamping and gear accessIntegral EEx e Terminal chamberFOR AMBIENT TEMPERATURE “T” RATINGS SEE TABLES AT REAR OF CATALOGUE

Options

Large range of lamp optionsLow and high temperature versionsColoured glass range

620 External reflector Swivel stirrup mounting

Page 14

6 Series EEx de620 Well Glass Range

ATEXCERTIFIED

CAT 11ZONE 1

Terminal block access

Page 15: About us - HANSEATIC SOLUTIONS · G40 Series GRP Terminal 45 Enclosures Atex directive In 2003 the Atex Directive becomes a mandatory requirement for all hazardous area equipment

Technical Data

Page 15

6 Series EEx de620 Well Glass Range

ATEXCERTIFIED

CAT 11ZONE 1

Supply Voltage 240v 50HzCheck for alternative voltages

Operating Temperature -20ºC to +40 ºC standard supplyFor operation at -45ºC or up to 90ºC consult sales office prior to ordering

Control Gear (when Fitted) Ballast, ignitor and capacitor can be fitted within the luminaire

Lamp Options Certified with elliptical lamps (Lamps not provided)150w SON-E and 250w SON-I125w and 250w HPMV/MBFUp to 300w GLS, 25w SL or 20w PLCE

Cable Entries 2 x M20 – ISO (1 plugged) as StandardOther threads available.

Terminals 4 (4mm) wire and earth with looping facilityCable crimping required at installation when looping

Mounting Facility Back mounted fixing strap

Access Terminals accessed via terminal cover retained by cap screwLamp and gear accessed via removable glass dome

Material Corrosion resistant marine grade aluminium body and bezelToughened Borosilicate glass dome

Finish 2 Pack epoxy paint on primed surface.Standard colour - AquaAdditional costs for non standard colours

Accessories Internal or external reflector Pivot bracket for directional controlPendant mountWire Guard

Weight 12.5 to 16.0 kgs

Features IIC as standardHeavy duty constructionGlass colouring availableHigh ambient temperature option available

Page 16: About us - HANSEATIC SOLUTIONS · G40 Series GRP Terminal 45 Enclosures Atex directive In 2003 the Atex Directive becomes a mandatory requirement for all hazardous area equipment

Certification and Approval

Certification Code EEx de II 2 GD IIC T3 – T6 (See lamp tables for T rating)Certification number SIRA 00 ATEX 1047Certification standard EN 60079-0, 1, 7Protection IP 66

Features

Shallow profile for confined spaceIIC as standardIntegral EEx e Terminal chamberHeavy duty construction

FOR AMBIENT TEMPERATURE “T” RATINGS SEE TABLES AT REAR OF CATALOGUE

Options

Shallow profile for confined spacesCow and high temperature versionsExtended lamp rangeColoured glass range

621 with wire guard Terminal block access andlocal external earthing

Coloured glass option

Page 16

6 Series EEx de621 Bulkhead Range

ATEXCERTIFIED

CAT 11ZONE 1

Page 17: About us - HANSEATIC SOLUTIONS · G40 Series GRP Terminal 45 Enclosures Atex directive In 2003 the Atex Directive becomes a mandatory requirement for all hazardous area equipment

Technical Data

Page 17

6 Series EEx de621 Bulkhead Range

ATEXCERTIFIED

CAT 11ZONE 1

Supply Voltage 240v 50HzCheck for alternative voltages

Operating Temperature -20ºC to +40 ºC standard supplyFor operation up to 90ºC consult sales office prior to ordering

Control Gear (when Fitted) Ballast, ignitor and capacitor all fitted within the luminaire

Lamp Options Certified with elliptical lamps (Lamps not provided)50w or 70w SON50w, 80w or 125w HPMV/MBFUp to 200w GLS

Cable Entries 2 x M20 – ISO (1 plugged) as StandardOther threads available.

Terminals 4 (4mm) wire and earth with looping facilityCable crimping required at installation when looping

Mounting Facility Back mounted fixing strap

Access Terminals accessed via terminal cover retained by cap screwLamp and gear accessed via removable glass dome

Material Corrosion resistant marine grade aluminium body and bezelToughened Borosilicate glass dome

Finish 2 Pack epoxy paint on primed surface.Standard colour - AquaAdditional costs for non standard colours

Accessories Internal or external reflector Pivot bracket for directional controlPendant mountWire Guard

Weight 12kgs to 14kgs lamp dependant

Features IIC as standardHeavy duty constructionGlass colouring availableHigh ambient temperature option available

Page 18: About us - HANSEATIC SOLUTIONS · G40 Series GRP Terminal 45 Enclosures Atex directive In 2003 the Atex Directive becomes a mandatory requirement for all hazardous area equipment

Certification and Approval

Certification Code EEx d II 2 G IIB or IIC T5 or T4 L (See lamp tables for T rating)Certification number SIRA 01 ATEX 1033Certification standard EN 60079-0, 1 Protection IP 66

Features

High Impact Resistant Polycarbonate lensAnodised marine grade Aluminium 50,000 hr electronic ballastEOL lamp protectionVibration resistantFOR AMBIENT TEMPERATURE “T” RATINGS SEE TABLES AT REAR OF CATALOGUE

Options

Wide range of voltage optionsLarge range of lamp optionsIP68 versionsThrough wiring

Easy lamp change system Threaded end cap Threaded mounting point

Page 18

7 Series EEx dStandard FluorescentLuminaire

ATEXCERTIFIED

CAT 11ZONE 1

Size12456

Model8w

18w36w58w70w

A335632

124215421806

B448752

136216621926

All dimensions in mm

Page 19: About us - HANSEATIC SOLUTIONS · G40 Series GRP Terminal 45 Enclosures Atex directive In 2003 the Atex Directive becomes a mandatory requirement for all hazardous area equipment

Technical Data

Page 19

7 Series EEx dStandard FluorescentLuminaire

ATEXCERTIFIED

CAT 11ZONE 1

Supply Voltage 230v 50/60HzCheck for alternative voltages

Operating Temperature -20ºC to +55ºC standard supply subject to lamp and ambient temperature combinations (see table opposite).

Control Gear Electronic instant start, Switch start

Lamp Options 8w (T5), 18w, 36w, 58w, 70w (T8) (Lamps not provided),Cable Entries 4 x M20 - 2 each end, (2 plugged) as standard

Terminals 3 wire and earth. Cable size 4mm2 maxThrough wiring option available on 18w to 70w sizes

Mounting Facility 2 x M8 tapped holes vertical and horizontal at both ends.

Access Terminals accessed via threaded end cover as is thegear tray which slides out.

Material Corrosion resistant marine grade anodised aluminium body and high impact polycarbonate tube.

Finish 2 Pack epoxy paint on primed surface.Standard colour - AquaAdditional costs for non standard colours

Weight Single Lamp 1 8w 3.0Kgs 2 18w 5.0Kgs4 36w 7.0Kgs 5 58w 8.0Kgs6 70w 9.0Kgs

Features Highly versatile luminaire with large lamp and voltage rangesDurable and slim line constructionRemovable lamp assembly for ease of lamp change.High IP rating

Page 20: About us - HANSEATIC SOLUTIONS · G40 Series GRP Terminal 45 Enclosures Atex directive In 2003 the Atex Directive becomes a mandatory requirement for all hazardous area equipment

Certification and Approval

Certification Code EEx d II 2 G IIB or IIC T5 or T4 (See lamp tables for T rating)Certification number SIRA 01 ATEX 1033Certification standard EN 60079-0, 1 Protection IP 66

Features

Internally mounted batteries giving 3 hr durationEOL lamp protection50,000 hour electronic ballast

FOR AMBIENT TEMPERATURE “T” RATINGS SEE TABLES AT REAR OF CATALOGUE

Options

Wide range of voltage optionsLarge range of lamp optionsIP68 versions

Internal charger inverter Separate battery chamber(some sizes)

Terminal block access

Page 20

7 Series EEx dEmergency FluorescentLuminaire

ATEXCERTIFIED

CAT 11ZONE 1

Size1245

Model8w

18w36w58w

A335632

12421542

B535839

14491662

All dimensions in mm

Page 21: About us - HANSEATIC SOLUTIONS · G40 Series GRP Terminal 45 Enclosures Atex directive In 2003 the Atex Directive becomes a mandatory requirement for all hazardous area equipment

Technical Data

Page 21

7 Series EEx dEmergency FluorescentLuminaire

ATEXCERTIFIED

CAT 11ZONE 1

Supply Voltage 230v 50/60HzCheck for alternative voltages. Suitable for central battery operation

Operating Temperature -20ºC to +55ºC standard supply subject to lamp and ambient temperature combinations (see table opposite).

Control Gear Electronic instant start, Switch start. One lamp lit in emergency mode

Lamp Options 8w (T5), 18w, 36w, 58w, (Lamps not provided)

Cable Entries 4 x M20 - 2 each end, (2 plugged) as standard

Terminals 3 wire and earth. Cable size 4mm2 maxThrough wiring option available on 18w to 70w sizes

Mounting Facility 2 x M8 tapped holes vertical and horizontal at both ends.

Access Terminals accessed via threaded end cover as is thegear tray which slides out.

Material Corrosion resistant marine grade anodised aluminium body and high impact polycarbonate tube.

Finish 2 Pack epoxy paint on primed surface.Standard colour - AquaAdditional costs for non standard colours

Weight Size 1 8w 5.1Kgs Size 2 18w 6.8KgsSize 3 36w 10.0KgsSize 4 58w 10.4KgsSize 5 70w 12.5Kgs

Features Highly versatile luminaire with large lamp and voltage rangesDurable and slim line constructionRemovable lamp assembly for ease of lamp change.High IP Rating

Page 22: About us - HANSEATIC SOLUTIONS · G40 Series GRP Terminal 45 Enclosures Atex directive In 2003 the Atex Directive becomes a mandatory requirement for all hazardous area equipment

Certification and Approval

Certification Code EEx d II 2 G IIB or IIC T6 - T5 or T4 (See lamp tables for T rating)Certification number SIRA 01 ATEX 1033Certification standard EN 60079-0, 1 Protection IP 66

Features

Extended life using PL lampsIIC as standardHigher output – smaller fitting50,000 hour electronic ballast

FOR AMBIENT TEMPERATURE “T” RATINGS SEE TABLES AT REAR OF CATALOGUE

Options

Range of voltagesThrough wiringIP68 versionsRange of mountings

Gear tray access and amp access

Lamp retaining clips on tray

Through wiring connectionplug

Page 22

7 Series EEx dCompact FluorescentLuminaire

ATEXCERTIFIED

CAT 11ZONE 1

Size12

Model8w

18w

A335632

B448752

All dimensions in mm

Page 23: About us - HANSEATIC SOLUTIONS · G40 Series GRP Terminal 45 Enclosures Atex directive In 2003 the Atex Directive becomes a mandatory requirement for all hazardous area equipment

Technical Data

Page 23

7 Series EEx dCompact FluorescentLuminaire

ATEXCERTIFIED

CAT 11ZONE 1

Supply Voltage 230v 50HzCheck for alternative voltages. Suitable for central battery operation.

Operating Temperature -25ºC to +52ºC subject to lamp and ambient temperature combinations

Control Gear Electronic instant start, Switch start

Lamp Options 11w, 18w,26w, 36w, 55wPL-S, PL-L, PL-C (Lamps not provided)

Cable Entries 2 x M20 – ISO (1 plugged) as StandardOther threads available.

Terminals 3 wire and earth. Cable size 4mm 2 maxThrough wiring option available on 8w to 55w sizes

Mounting Facility 2 x M8 tapped holes vertical and horizontal at both ends.

Access Terminals accessed via threaded end cover as is the gear tray which slides out

Material Corrosion resistant marine grade aluminium body and high impact polycarbonate tube.

Finish 2 Pack epoxy paint on primed surface.Standard colour - AquaAdditional costs for non standard colours

Weight Size 1 11w, 18w, 26w 4.5Kgs Size 2 18w,26w, 55w, 6.8Kgs

Features IIC as standardHeavy duty constructionHigh ambient temperature option available

Page 24: About us - HANSEATIC SOLUTIONS · G40 Series GRP Terminal 45 Enclosures Atex directive In 2003 the Atex Directive becomes a mandatory requirement for all hazardous area equipment

Certification and Approval

Certification Code EEx de II 2 GD IIB T2 – T3 (See lamp tables for T rating)

Certification number SIRA 01 ATEX 1035Certification standard EN 60079-0, 1, 7Protection IP 66Features

Rapid re – lamping through threaded access coverNarrow/Wide angle beam adjustmentSymmetrical reflector as standardIntegral EEx e Terminal chamber

FOR AMBIENT TEMPERATURE “T” RATINGS SEE TABLES AT REAR OF CATALOGUE

Options

Mounting bracket options0.9 power factor when fitted

Lamp access cover Beam adjustment Angular adjustment mounting plate

Page 24

8 Series EEx deAdjustable angle FloodLight range

ATEXCERTIFIED

CAT 11ZONE 1

Page 25: About us - HANSEATIC SOLUTIONS · G40 Series GRP Terminal 45 Enclosures Atex directive In 2003 the Atex Directive becomes a mandatory requirement for all hazardous area equipment

Technical Data

Page 25

8 Series EEx deAdjustable angle FloodLight range

ATEXCERTIFIED

CAT 11ZONE 1

Supply Voltage 230v 50HzCheck for alternative voltages and frequency.

Operating Temperature -20ºC to +55ºC standard supply but subject to lamp, voltage and ambient temperature combinations .

Control Gear Integral within the luminaire and optional power factor correction

Lamp Options Tubular: SON, MBI, HPMV, Tungsten. Symmetrical reflector fitted to all versions. (Lamps not provided)

Cable Entries 2 x M20 – ISO (1 plugged) as StandardOther threads available.

Terminals 2 wire and earth. Cable size 6mm 2 max with looping facility

Mounting Facility Rear pole mounting directly to body or for adjustable angle version order with “U” shaped stirrup and graduated angle bracket.

Access Terminals accessed via EEx e terminal cover with 4 stainless steel fixings. Lamp change via threaded lamp cover for reduced maintenance time.

Material Corrosion resistant marine grade aluminium body and covers and toughened Borosilicate glass.

Finish 2 Pack epoxy paint on primed surface.Standard colour - AquaAdditional costs for non standard colours.

Weight SON, MBI, HPMV 33KgsTungsten 29Kgs

Features Adjustable beam widthSymmetrical reflector fitted to all versions Heavy Duty constructionDirectionally adjustable with stirrup mounting bracket

Page 26: About us - HANSEATIC SOLUTIONS · G40 Series GRP Terminal 45 Enclosures Atex directive In 2003 the Atex Directive becomes a mandatory requirement for all hazardous area equipment

Certification and ApprovalCertification Code EEx ed II 2G 3D IIC T5 – T4 (See lamp tables for T rating)Certification number SIRA 00 ATEX 3071. IECEx SIR 08.0089Certification standard EN 60079-0, 11:2006. EN60079-1, 7:2007.

EN61241-1:2004. IEC 60079-0:2007Protection IP 65Features

Integral isolation switch as standardSingle point locking actionEOL lamp shut downHigh light outputIntegral battery with 3 hr. duration on emergency versionsFOR AMBIENT TEMPERATURE “T” RATINGS SEE TABLES AT REAR OF CATALOGUE

Options

Alternative voltagesThrough wiring Omission of isolation switch

Single point diffuser release Terminal block access Rear mounting channelfor T bolt

Page 26

9 Series Standard and EmergencyFluorescent Luminaire

ATEXCERTIFIED

CAT 11ZONE 1

Size2x18w2x36w2x58w

Length760

13651665

Fixing cetres100 up to

45010551355

All dimensions in mm

Page 27: About us - HANSEATIC SOLUTIONS · G40 Series GRP Terminal 45 Enclosures Atex directive In 2003 the Atex Directive becomes a mandatory requirement for all hazardous area equipment

Technical Data

Page 27

9 Series Standard and EmergencyFluorescent Luminaire

ATEXCERTIFIED

CAT 11ZONE 1

Supply Voltage 230v 50/60Hz standard, 110v , 254v and 277v optional on some 18w and 36w. 60Hz also optional. Suitable for central battery operation.

Operating Temperature -20ºC to +55ºC standard supply subject to ambient temperature requirements.

Control Gear Electronic instant start ballast and integral charger inverter for emergency versions. EOL cut off. 3hr operation with internal battery subject to ambient temperature.

Lamp Options Twin 18w, 36w, 58w (Lamps not provided)

Cable Entries 2 x M20 at each end (3 plugged as Standard)

Terminals 3 wire and earth. Cable size 4mm 2 maxThrough wiring option available

Mounting Facility 2 x M8 “Quick fit” bolts available on variable centres for ease of mounting.

Access Terminals accessed via quick release diffuser and reflector.

Material Anodised corrosion resistant Aluminium and high impact polycarbonate diffuser and body mouldings. UV Resistant.

Finish Standard colour – Aqua body mouldings natural aluminium for body centre section

Weight Standard Emergency

2x 18w 6.8Kgs 7.0Kgs2 x 36w 10.4Kgs 11.2Kgs2 x 58w 12.0Kgs 13.0Kgs

Features Excellent light outputHeavy duty rigid constructionInternal automatic isolation (may be omitted upon request)110v , 254v and 277v available.

Page 28: About us - HANSEATIC SOLUTIONS · G40 Series GRP Terminal 45 Enclosures Atex directive In 2003 the Atex Directive becomes a mandatory requirement for all hazardous area equipment

Certification and Approval

Certification Code EEx ed II 2G 3DIIC T5 – T4 (See lamp tables for T rating)Certification number SIRA 00 ATEX 3106Certification standard EN 60079-0, 11:2006. EN60079-1, 7:2007. Protection IP 54

Features

Flush fitting – minimizing dust build upEOL lamp shut downIntegral battery with 3hr duration on emergency versionsFOR AMBIENT TEMPERATURE “T” RATINGS SEE TABLES AT REAR OF CATALOGUE

Options

Alternative voltagesThrough wiring Omission of isolation switch

Terminal block access Rear mounting foot Ballast & lampholder pack

Page 28

9R Series EEx edStandard and EmergencyRecessed FluorescentLuminaire

ATEXCERTIFIED

CAT 11ZONE 1

All dimensions in MM

Size A B C2 x 18 802 752 6422 x 36 1402 1352 12422 x 58 1702 1652 1542

Page 29: About us - HANSEATIC SOLUTIONS · G40 Series GRP Terminal 45 Enclosures Atex directive In 2003 the Atex Directive becomes a mandatory requirement for all hazardous area equipment

Technical Data

Page 29

9R Series EEx edStandard and EmergencyRecessed FluorescentLuminaire

ATEXCERTIFIED

CAT 11ZONE 1

Supply Voltage 230v 50/60Hz standard, 110v , 254v and 277 v optional on some 18w and 36w. 60Hz also optional. Suitable for central battery operation.

Operating Temperature -20ºC to +55ºC standard supply subject to ambient temperature requirements.

Control Gear Electronic instant start ballast and integral charger inverter for emergency versions. EOL cut off. 3hr operation with internal battery subject to ambient temperature.

Lamp Options Twin 18w, 36w, 58w T8 (Lamps not provided)

Cable Entries 2 x M20 clearance holes at each end (3 plugged as Standard)

Terminals 3 wire and earth. Cable size 4mm2 maxThrough wiring option available

Mounting Facility 4 fixing holes on rear of enclosure.

Access Remove toughened glass front panel and quick release diffuser.

Material Polyester coated steel and toughened glass in an aluminium frame.

Finish Standard colour – White polyester coated

Weight Standard Emergency2x 18w 12.0Kgs 10.0Kgs2 x 36w 14.0Kgs 13.0Kgs2 x 58w 15.0Kgs 15.0Kgs

Features Flush fitting closing panel minimising dust and bacterial build upHeavy duty rigid constructionInternal automatic isolation (may be omitted upon request)110v , 254v and 277v available.

Page 30: About us - HANSEATIC SOLUTIONS · G40 Series GRP Terminal 45 Enclosures Atex directive In 2003 the Atex Directive becomes a mandatory requirement for all hazardous area equipment

Certification and Approval

Certification Code EEx nC II 3GD T4 -40ºC to +55ºC Certification number Epsilon 02 ATEX 1167Certification standard EN 60079-0, 15Protection IP 65

Features

Unrestricted breathingNo vacuum test requiredIntegral battery with 3hr duration on emergency versions

Options

Closed cell gasketPush fit gear trayStainless steel clips

Gear tray clips Lamp mounting Diffuser clips

Page 30

EXENStandard and EmergencyFluorescent Luminaire

ATEXCERTIFIED

CAT IIIZONE 2

Size1x36w1x58w2x18w2x36w2x58w

L13121612702

13121612

W102102172172172

F800

1100500800

1100

All dimensions in mm

Page 31: About us - HANSEATIC SOLUTIONS · G40 Series GRP Terminal 45 Enclosures Atex directive In 2003 the Atex Directive becomes a mandatory requirement for all hazardous area equipment

Technical Data

Page 31

EXENStandard and EmergencyFluorescent Luminaire

ATEXCERTIFIED

CAT IIIZONE 2

Supply Voltage 230v 50/60Hz standard. Suitable for central battery operation.

Operating Temperature -40ºC to +55ºC standard supply subject to ambient temperature requirements.

Control Gear Electronic instant start ballast and integral charger inverter for emergency versions. EOL cut off. 3hr operation with internal battery subject to ambient temperature.

Lamp Options Twin 18w, 36w, 58w T8 (Lamps not provided)Single 36w and 58w T8 (Lamps not provided)

Cable Entries 1 x M20 clearance holes at each end (1 plugged as Standard)

Terminals 3 wire and earth. Cable size 4mm2 maxThrough wiring option available

Mounting Facility 2 drill through fixing points on rear of enclosure or “snap on” stainless steel brackets or heavy duty “gull wing” bracket available

Access Quick release stainless steel clips to free diffuser and spring clips release gear tray.

Material GRP moulded body, polycarbonate diffuser and coated steel control gear tray. Stainless steel diffuser and tray retaining clips

Finish Standard colour – Light grey non coated moulding

Weight Standard Emergency2x 18w 2.8gs 3.8Kgs2 x 36w 3.6gs 4.6Kgs2 x 58w 5.0Kgs 5.6Kgs1 x 36w 3.2kgs 4.0Kgs1 x 58w 3.4Kgs 4.2Kgs

Features Resilient constructionPoured seal or closed cell gasketUnrestricted breathing for minimum inspection requirementsEasily maintained.

Page 32: About us - HANSEATIC SOLUTIONS · G40 Series GRP Terminal 45 Enclosures Atex directive In 2003 the Atex Directive becomes a mandatory requirement for all hazardous area equipment

Certification and Approval

Certification Code EEx nC II 3GD T6 or T3 (See lamp tables for T rating)Certification number 03 ATEX TF457/01Certification standard EN 60079-0, 15Protection IP 68 to 15M subject to appropriate glanding

Features

Heavy duty cast iron construction Low projection and rounded profileIdeal for culvert and water treatment worksHigh IP rating for arduous conditions

Options

Alternative voltagesThrough wiring Lamp source variants

Cable entry Lamp access Terminal block access

Page 32

457 Submersible Bulkhead Luminaire

ATEXCERTIFIED

CAT IIIZONE 2

Page 33: About us - HANSEATIC SOLUTIONS · G40 Series GRP Terminal 45 Enclosures Atex directive In 2003 the Atex Directive becomes a mandatory requirement for all hazardous area equipment

Technical Data

Page 33

457 Submersible Bulkhead Luminaire

ATEXCERTIFIED

CAT IIIZONE 2

Supply Voltage 230v 50Hz standard..

Operating Temperature -20ºC to +40ºC standard supply subject to ambient temperature requirements.

Control Gear For use with GLS lamp or 25w compact fluorescent. No control gear required.

Lamp Options 150w GLS or 25w compact fluorescent, 70w SON (Lamps not supplied)

Cable Entries x M20 Threaded entry. Available both ends as option

Terminals 2 wire and earth. Cable size 4mm2 max

Mounting Facility 4 cast in fixing lugs to take M8 screws.

Access Remove bezel retaining screws to release glass lens and gasket

Material Cast iron body and bezel, glass lens and coated wire guard

Finish 2 Pack epoxy paint on primed surface.Standard colour – Aqua and white plastic coated guardAdditional costs for non standard colours.

Weight 9.0Kgs

Features Very heavy construction.Low projection and rounded profileIdeal for culvert and water treatment worksHigh IP rating for arduous conditions

Page 34: About us - HANSEATIC SOLUTIONS · G40 Series GRP Terminal 45 Enclosures Atex directive In 2003 the Atex Directive becomes a mandatory requirement for all hazardous area equipment

Certification and Approval

Certification Code EEx nC II 3GD T3 (See lamp tables for T rating)Certification number 03 ATEX TFDN/01Certification standard EN 60079-0, 15Protection IP 65

Features

Rapid lamp and control gear access Even light distributionHinged lens opening

Options

Lamp source variantsPower factor correction Various lamp options available

Hinged lens opening Screwed bezel fixings Integral mounting feet

Page 34

DN Series Bulk head Luminaire

ATEXCERTIFIED

CAT IIIZONE 2

Page 35: About us - HANSEATIC SOLUTIONS · G40 Series GRP Terminal 45 Enclosures Atex directive In 2003 the Atex Directive becomes a mandatory requirement for all hazardous area equipment

Technical Data

Page 35

DN Series Bulk head Luminaire

ATEXCERTIFIED

CAT IIIZONE 2

Supply Voltage 230v 50Hz standard.

Operating Temperature -20ºC to +30ºC standard supply subject to ambient temperature requirements.

Control Gear Integral within the luminaire and optional power factor correction

Lamp Options Elliptical: 70w SON80w HPMV200w GLSTwin 26w PL

Cable Entries 2 x M20 Threaded entries at one end (1 plugged).

Terminals 2 wire and earth. Cable size 4mm2 max

Mounting Facility 4 cast in fixing lugs to take M8 screws.

Access Unscrew retaining screws to open hinged lens.

Material Die cast aluminium body and bezel and borosilicate glass lens

Finish Grey Powder coating or 2 Pack epoxy paint on primed surface.Additional costs for non standard colours.

Weight 70w and 80w 6.0Kgs 200w 4.0Kgs

FeaturesRapid lamp and control gear access Even light distributionVarious lamp options available

Page 36: About us - HANSEATIC SOLUTIONS · G40 Series GRP Terminal 45 Enclosures Atex directive In 2003 the Atex Directive becomes a mandatory requirement for all hazardous area equipment

Certification and Approval

Certification Code EEx nR II 3GD T3 Certification number 05 ATEX TFZT/01Certification standard EN 60079-0, 15 Protection IP 66

Features

Symmetrical reflector fitted to all versions Easy lamp accessRobust constructionDirectionally adjustable with stirrup mounting bracket

Options

Lamp source variantsPower factor correction Non standard colour

Hinged lens opening Cable entry and termination block

Adjustable anglemounting stirrup

Page 36

ZT Adjustable Angle Flood Light Range

ATEXCERTIFIED

CAT IIIZONE 2

Page 37: About us - HANSEATIC SOLUTIONS · G40 Series GRP Terminal 45 Enclosures Atex directive In 2003 the Atex Directive becomes a mandatory requirement for all hazardous area equipment

Technical Data

Page 37

ZT Adjustable Angle Flood Light Range

ATEXCERTIFIED

CAT IIIZONE 2

Supply Voltage 230v 50Hz standard..

Operating Temperature -20ºC to +30ºC standard supply subject to ambient temperature requirements.

Control Gear Integral within the luminaire and optional power factor correction when fitted.

Lamp Options Tubular: SON, MBI, Tungsten. 70w to 500wAsymmetrical reflector fitted to all versions. (Lamps not provided)

Cable Entries 1 x M20 clearance hole in side of body.Terminals 2 wire and earth. Cable size 4mm2 max

Mounting Facility “U” shaped stirrup bracket with angle adjustment mechanism.

Access Unscrew 2 stainless steel screws in hinged glass retaining frame.

Material Corrosion resistant die cast aluminium and toughened glass lens.

Finish 2 Pack epoxy paint on primed surface.Standard colour – Aqua .Additional costs for non standard colours.

Weight 19.5Kgs to 21Kgs Lamp dependant.

Features Symmetrical reflector fitted to all versions Robust constructionDirectionally adjustable with stirrup mounting bracket

Page 38: About us - HANSEATIC SOLUTIONS · G40 Series GRP Terminal 45 Enclosures Atex directive In 2003 the Atex Directive becomes a mandatory requirement for all hazardous area equipment

Certification and Approval

Industrial LuminaireBulk head fitting suitable for non hazardous industrial and commercial applicationsAvailable in a range of lamp formats including energy efficient PL’s Emergency versionwith integral battery available with PL lamps (not supplied) Ingress Protection IP 65

Features

Hinged lens openingRapid lamp and control gear access Even light distribution

Options

Lamp source variantsPower factor correction Various lamp options available

Hinged lens opening Screwed bezel fixings Integral mounting feet

Page 38

DB Series GeneralIndustrial Bulk headLuminaire

Page 39: About us - HANSEATIC SOLUTIONS · G40 Series GRP Terminal 45 Enclosures Atex directive In 2003 the Atex Directive becomes a mandatory requirement for all hazardous area equipment

Technical Data

Page 39

DB Series GeneralIndustrial Bulk headLuminaire

Supply Voltage 230v 50Hz standard..

Operating Temperature -20ºC to +25ºC standard supply subject to ambient temperature requirements.

Control Gear Integral within the luminaire and optional power factor correction. Emergency version available for PL lamps

Lamp Options Elliptical: 70w SON80w HPMV200w GLSPL 28w

Cable Entries 2 x M20 Threaded entries at one end (1 plugged).

Terminals 2 wire and earth. Cable size 4mm2 max

Mounting Facility 4 cast in fixing lugs to take M8 screws.

Access Unscrew retaining screws to open hinged lens.

Material Die cast aluminium body and bezel and borosilicate glass lens

Finish Grey powder coated or 2 Pack epoxy paint on primed surface.Additional costs for non standard colours.

Weight 70w and 80w 8.0Kgs200w 6.5KgsPL 7.0 KgsPL emergency 8.0 Kgs

Features Rapid lamp and control gear access Even light distributionVarious lamp options available

Page 40: About us - HANSEATIC SOLUTIONS · G40 Series GRP Terminal 45 Enclosures Atex directive In 2003 the Atex Directive becomes a mandatory requirement for all hazardous area equipment

Certification and ApprovalCertification Code EEx d II 2 GD IIB T4, T5 or T6 (contents dependant) Certification number Demko 03 ATEX 134333XCertification standard EN 50014, EN 50018Operating temperature -20ºC to +40ºC Protection IP65

Features

Heavy duty cast enclosuresWide size range for efficient use of spaceClose coupling option for Isolation unit if requiredCable entries M20 to M75

G21 starter

G27 and G23 control panels

Socket G23 starter isolator Cable entry positioning

Page 40

G20 SeriesMotor Starters andIsolators

ATEXCERTIFIED

CAT 11ZONE 1

Ordering Equipment - information required

Kilowatt rating Full load currentCable entry size Cable sizeCable entry quantity Voltage and frequencyStarter type, DOL , Star Delta, Reversing 2 speed etcOther specific requirements

Page 41: About us - HANSEATIC SOLUTIONS · G40 Series GRP Terminal 45 Enclosures Atex directive In 2003 the Atex Directive becomes a mandatory requirement for all hazardous area equipment

G20 SeriesMotor Starters and Isolators

ATEXCERTIFIED

CAT 11ZONE 1

Page 41

Standard Ranges

Motor starters 0.25kw to 350kwDirect on Line, Star Delta and Reversing

Optional Extras Isolators, Status Indicators, TransformersRelays, Fuses, switches

G21 Units Control stations up to 4 gang with shrouded ormushroom head and stay put optionsSwitches up to 6 pole 10 amp or 3 pole 24 amp.

Finish 2 pack grey epoxy coating over etching primer.Other colours at additional cost

Page 42: About us - HANSEATIC SOLUTIONS · G40 Series GRP Terminal 45 Enclosures Atex directive In 2003 the Atex Directive becomes a mandatory requirement for all hazardous area equipment

G20 SeriesMotor Starters and Isolators

ATEXCERTIFIED

CAT 11ZONE 1

Page 42

EExd IIB Standard Units

Page 43: About us - HANSEATIC SOLUTIONS · G40 Series GRP Terminal 45 Enclosures Atex directive In 2003 the Atex Directive becomes a mandatory requirement for all hazardous area equipment

G2 Range of CastEnclosures and CustomBuilt Control Panels

ATEXCERTIFIED

CAT 11ZONE 1

Page 43

Certification and ApprovalCertification Code EEx d II 2 GD IIB T4, T5 or T6 (contents dependant) Certification number Demko 03 ATEX 134333XCertification standard EN 50014, EN 50018Operating temperature -20ºC to +40ºC Protection IP65

Features

High quality heavy duty cast enclosuresWide size range for efficient use of spaceClose coupling option for Isolation unit if required Cable entries M20 to M75.

Typical panels Cable entry positioning Starter isolator

G26 control panel

Ordering Equipment - information required

Kilowatt rating Full load currentCable entry size Cable sizeCable entry quantity Voltage and frequencyStarter type, DOL , Star Delta, Reversing 2 speed etcOther specific requirements

Page 44: About us - HANSEATIC SOLUTIONS · G40 Series GRP Terminal 45 Enclosures Atex directive In 2003 the Atex Directive becomes a mandatory requirement for all hazardous area equipment

G2 Range of CastEnclosures & Custom Built Control Panels

ATEXCERTIFIED

CAT 11ZONE 1

Page 44

Standard Ranges

Motor starters 0.25kw to 350kwDirect on Line, Star Delta and Reversing

Optional Extras Isolators, Status Indicators, TransformersRelays, Fuses, switches

Distribution Up to 600AMCB/MCCB panels, RCCD protection,Fuse boards, Isolator/switch disconnectors

G21 Units Control stations up to 4 gang with shrouded or mushroom head and stay put optionsSwitches up to 6 pole 10 amp or 3 pole 24 amp.

Finish 2 pack grey epoxy coating over etching primer.Other colours at additional cost.

Page 45: About us - HANSEATIC SOLUTIONS · G40 Series GRP Terminal 45 Enclosures Atex directive In 2003 the Atex Directive becomes a mandatory requirement for all hazardous area equipment

G40 Series GRP Terminal Enclosures

ATEXCERTIFIED

CAT 11ZONE 1

Page 45

Certification and Approval

Certification Code EEx e dm ia II 2 GD IIC T6Certification number PTB 00 ATEX 1002Certification standard EN60079-0, 1, 7, 11, 18, EN50281-1-1-1999+A1Protection IP66

Features

Heavy duty GRP mouldingSilicone weather sealGraphite loaded material to minimise static build up.

Typical terminal arrangement

Oktabox cable entry andterminal arrangement

Oktabox external mounting foot

G48 and G49 Oktabox

Page 46: About us - HANSEATIC SOLUTIONS · G40 Series GRP Terminal 45 Enclosures Atex directive In 2003 the Atex Directive becomes a mandatory requirement for all hazardous area equipment

G40 Series GRP Terminal Enclosures

ATEXCERTIFIED

CAT 11ZONE 1

Page 46

Technical Data

Voltage/Current ratings Dependant upon Ex components fitted and conductors used

Operating Temperature T6 -20ºC to +40ºC, T5 -20ºC to +55ºC

Terminals 2.5 up to 120 – subject to enclosure limits

Flammability Self Extinguishing, UL 94/VUse handle and cable gland for plug4 fixing holes on plug to handle units

Material Glass reinforced duroplastic polyester, graphite added Halogen Free

Colour/Finish Black as moulded

Mounting G41 – G47 Internal fixing holesG48 & G49 External fixing holes

Features Silicone weather sealHeavy duty GRP mouldingsGraphite loaded material to minimise static build up

Page 47: About us - HANSEATIC SOLUTIONS · G40 Series GRP Terminal 45 Enclosures Atex directive In 2003 the Atex Directive becomes a mandatory requirement for all hazardous area equipment

Well Glass, Flood Light &Bulkhead LuminâresSpares and Accessories

Page 47

Page 48: About us - HANSEATIC SOLUTIONS · G40 Series GRP Terminal 45 Enclosures Atex directive In 2003 the Atex Directive becomes a mandatory requirement for all hazardous area equipment

Fluorescent Luminâres and Spares and Accessories

Page 48

Page 49: About us - HANSEATIC SOLUTIONS · G40 Series GRP Terminal 45 Enclosures Atex directive In 2003 the Atex Directive becomes a mandatory requirement for all hazardous area equipment

Page 49

Fluorescent Luminâres andSpares and Accessories

Page 50: About us - HANSEATIC SOLUTIONS · G40 Series GRP Terminal 45 Enclosures Atex directive In 2003 the Atex Directive becomes a mandatory requirement for all hazardous area equipment

Lamp Tables and 'T' ratingsfor ambient temperatures

Ambient Temperatures ‘T’ ratings

610 Beacon 620 Well Glass

610 Well Glass

Static Beacons: T4 @ Ta = 400C GLST4 @ Ta = 700C SL/PLCE

Xenon warning lights: T4 @ Ta = 550CRotating: T4 @ Ta = 700C

Certified with elliptical lampsMax. 200w GLS T3 @ Ta = 550C.125w HPMV/MBF T4 @ Ta = 400C or T3 @ Ta = 600CMax. 25w SL or 20w PLCE T6 @ Ta = 400C or T5 @ Ta = 600CAll with ES (E27) lampholder

300w GLS T3 @ Ta = 550C150w SON T4 @ Ta = 400C or T3 @ Ta = 600C250w SON I T3 @ Ta = 400C250w MBI T3 @ Ta = 400C250w HMPV/MBF T3 @ Ta = 390CAll with GES (E40) lampholder.Standard temperature classification applies to all methods of mounting.Up to 200w GLS BC also available.

Lamps are not includedHigh temperature version (at extra cost).300w GLS T3 @ Ta = 850C150w SON T3 @ Ta = 900C250w SON-I T3 @ Ta = 700C250w MBI T3 @ Ta = 700C125w HPMV T3 @ Ta = 900C250w HPMV T2 @ Ta = 650C or T3 @ Ta = 500CN.B. For Ta up to 600C cable must be suitablefor 1160C operation. Above Ta 600C cable must besuitable for 1460C operation

Certified with elliptical lamps.Max. 150w GLS T4 @ Ta =400C50 or 70w SON-E T4 @ Ta =400C110w SON-E T4 @ Ta =400C70w SON-R T3 @ Ta =550C50w or 80w HPMV/MBF T4 @ Ta =400C125w HPMV/MBF T3 @ Ta =350CMax.25w SL or20w PLCE T4 @ Ta =700CAll with ES (E27) lampholder.Up to 150w GLS BC also available T4 @ Ta =400CLamps are not included.N.B. temp. classifications can be improvedif mounted vertically.

Page 50

Page 51: About us - HANSEATIC SOLUTIONS · G40 Series GRP Terminal 45 Enclosures Atex directive In 2003 the Atex Directive becomes a mandatory requirement for all hazardous area equipment

Lamp tables and ‘T’ratings for ambienttemperatures

ATEXCERTIFIED

Page 51

621 BulkheadCertified with elliptical or tubular lamps.Max. 200w GLS T4 @ Ta = 340C50w or 70w SON T4 @ Ta = 400Cor T3 @ Ta = 600C50w or 80w HPMV/MBF T4 @ Ta = 400Cor T3 @ Ta = 600C125w HPMV/MBF T4 @ Ta = 400CMax. 25w SL or 20w PLCE T6 @ Ta = 700Cor T5 @ Ta = 600CAll with ES (E27) lampholder.Up to 200w BC also available. T4 @ Ta = 340CHigh temperature version (at extra cost).200w GLS T3 @ Ta = 600C70w SON T3 @ Ta = 900C80w HPMV/MBF T3 @ Ta = 900C125w HPMV/MBF T3 @ Ta = 700C25w SL or 20w PLCE T5 @ Ta = 600CLamps not includedN.B. For Ta up to 600C cable must be suitable for1160C operation. Above Ta 600C cable must besuitable for 1460C operation.

7 series CompactLamp source options: Standard fluorescentSize 1 1 or 2 x 11w max PL-S T4 @ Ta=520C

1 or 2 x 18w max PL-L1 or 2 x 26w max PL-C T5 @ Ta=400C

Size 2 1 or 2 x 36w max PL-L T6 @ Ta=400C1 or 2 x 55w max PL-L (HF only) T6 @ Ta=400CEmergency fluorescent

Size 1 1 x 18w max PL-L EM T4 @ Ta=520CSize 2 1 x 2 x 36w max PL-L EM T6 @ Ta=400C

8 series Flood LightLamp source options: 80w, 250w HPMV T3 @ Ta = 550C (D=T1470C)With ES (E27) lampholder.

150w, 250w SON T3 @ Ta = 550C (D=T1470C)250w MBI T3 @ Ta = 550C (D=T1470C)500w Tung Halogen T3 @ Ta = 550C (D=T1750C)250w HPMV T3 @ Ta = 550C (D=T1470C)400w SON/MBI T3 @ Ta = 400C (D=T1470C)400w, HPMV T3 @ Ta = 400C (D=T1470C)500w, Tung Halogen T3 @ Ta = 550C (D=T1730C)150w, 250w SON T3 @ Ta = 400C (D=T1270C)

7 series FluorescentLamp source options: Certification data: All options certified for -250C

8w T5 @ Ta=400C T4 @ Ta=520C EEx d IIC18w T6 @ Ta=400C T5 @ Ta=550C EEx d IIC36w T6 @ Ta=400C T5 @ Ta=550C EEx d IIB58w T6 @ Ta=400C T5 @ Ta=550C EEx d IIB70w T5 @ Ta=400C T4 @ Ta=550C EEx d IIB

9 series FluorescentAll options certified for -200C to +550CAll variations: T5 @ Ta 250C

T4 @ Ta 550C

9R series Fluorescent

All options certified for -200C to +550CEEx ed IIC T5 @ Ta 250C or T4 @ 550C

Emergency RangeLamp source options: Certification data: All options ceetified for -250C

8w T6 @ Ta=400C T6 @ Ta=520C EEx d IIC18w T6 @ Ta=400C T5 @ Ta=550C EEx d IIC36w T6 @ Ta=400C T5 @ Ta=550C EEx d IIB58w T6 @ Ta=400C T5 @ Ta=550C EEx d IIB