About this manual - Fujitsu Global ·  · 2008-06-03PRIMERGY RX100 S5 Configuration Sheets D...

33
PRIMERGY RX100 S5 Configuration Sheets D Design Sheet of the RAID Configuration Use this form to record the definitions of the disk groups (or the physical packs) and the logical drives in the RAID configuration (array configuration). E Design Sheet Use this form to record the software settings. F Accident Sheet Use this form to record any failures that occur in your server. A Configuration Sheets of Hardware Use this form to record the hardware configuration and various settings of your server. B Configuration Sheets of BIOS Setup Utility Parameters Use this form to record the settings of the BIOS Setup Utility. C Configuration Sheets of Remote Management Controller's Web Interface Use this form to record the settings of the Remote Management Controller Web interface. About this manual 1

Transcript of About this manual - Fujitsu Global ·  · 2008-06-03PRIMERGY RX100 S5 Configuration Sheets D...

PRIMERGY RX100 S5 Configuration Sheets

D Design Sheet of the RAID Configuration Use this form to record the definitions of the disk groups (or the physical packs) and the logical drives in the RAID configuration (array configuration).

E Design Sheet Use this form to record the software settings.

F Accident Sheet Use this form to record any failures that occur in your server.

A   Configuration Sheets of Hardware   Use this form to record the hardware configuration and various settings of your server.

B Configuration Sheets of BIOS Setup Utility Parameters Use this form to record the settings of the BIOS Setup Utility.

C Configuration Sheets of Remote Management Controller's Web Interface Use this form to record the settings of the Remote Management Controller Web interface.

About this manual

1

The following expressions and abbreviations are used to describe the product names used in this manual.

Product names

PRIMERGY RX100 S5 This server or the server

Microsoft® Windows Server® 2003 R2, Standard Edition Windows Server 2003 R2, Standard Edition

Windows 2003

Microsoft® Windows Server® 2003, Standard Edition Windows Server 2003, Standard Edition

Microsoft® Windows Server® 2003 R2, Standard x64 Edition Windows Server 2003 R2, Standard x64 Edition

Microsoft® Windows Server® 2003, Standard x64 Edition Windows Server 2003, Standard x64 Edition

Microsoft® Windows Server® 2003 Service Pack SP

■Trademarks

Microsoft, Windows, MS, Windows Server are registered trademarks of the Microsoft Corporation in the USA and other

countries.

Intel,Xeon,Celeron and Core 2 Duo are registered trademarks or trademarks of Intel Corporation or its subsidiaries in the

USA and other countries.

All other hardware and software names used are trademarks or registered trademarks of their respective manufacturers.

Other product names are copyrights of their respective manufacturers.

All Rights Reserved, Copyright© FUJITSU LIMITED 2008

Expressions and abbreviations

Product Names

2

PRIMERGY RX100 S5 Configuration Sheets

A Configuration Sheets of Hardware ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 4

B Configuration Sheets of BIOS Setup Utility Parameters ・・・・・・・・・・・・ 5

B.1 Parameters in the Main Menu ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 5

B.2 Parameters in the Advanced Menu ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 6

B.3 Parameters in the Security Menu ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 9

B.4 Parameters in the Power Menu ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 9

B.5 Parameters in the Server Menu ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 10

B.6 Parameters in the Boot Menu ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 12

B.7 Parameters in the Exit Menu ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 12

Interface ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 13

C.1 Parameters in the iRMC S2 ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 13

C.2 Parameters in the Power Management ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 14

C.3 Parameters in the Power Consumption ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 15

C.4 Parameters in the Fans ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 16

C.5 Parameters in the Temperature ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 16

C.6 Parameters in the System Event Log ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 16

C.7 Parameters in the Server Management Information ・・・・・・・・・・・・・・・・・・・・・・・・・・ 17

C.8 Parameters in the Network Settings ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 18

C.9 Parameters in the SNMP Trap Alerting ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 19

C.10 Parameters in the Email Alerting ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 19

C.11 Parameters in the User Management ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 20

C.12 Parameters in the LDAP Configuration ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 23

C.13 Parameters in the BIOS Text Console ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 23

C.14 Parameters in the Advanced Video Redirection ・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 23

D Design Sheet of the RAID Configuration ・・・・・・・・・・・・・・・・・・・・・・・・ 24

D.1 For Integrated Mirroring SAS ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 24

D.2 For Embedded MegaRAID SATA ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 24

E Design Sheet ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 25

E.1 RAID/Disk Wizard ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 25

E.2 OS Wizard (Windows 2003 Install Wizard) ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 26

E.3 Application Wizard ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 31

F Accident Sheet ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 32

C Configuration Sheets of Remote Management Controller's Web

Contents

3

A Configuration Sheets of Hardware

Use this form to record the hardware configuration and various settings of your server.Put a check mark in parentheses of your server settings.

■3.5-inch Internal Options●SAS model

Installed position

Bay 1Bay 2

*1: Bay located to either the left viewed from the server front.

*2: Bay located to either the right viewed from the server front.

●SATA model

Installed position

Bay 1Bay 2

*1: Bay located to either the left viewed from the server front.

*2: Bay located to either the right viewed from the server front.

■Thin 5 inches bay Options

Installed position

Thin 5 inches bay

■RAM module

Installation slot

Slot 1ASlot 1BSlot 2ASlot 2B

■CPU

■PCI card

1 2( ) ( )( ) ( )( ) ( )( ) ( )

-:Indicates that this item cannot be installed.

Slot 1 is to the left viewed from the rear.

( ) Intel® Celeron® Processor 430 (1.80GHz/512KB)( ) Intel® Xeon® Processor 3065 (2.33GHz/4MB) ( ) Intel® Xeon® Processor E3110 (3GHz/6MB)

LAN card (PGB2861L/PG-2861L)

( ) Intel® Xeon® Processor X3220 (2.40GHz/2x4MB)( ) Intel® Core 2 Duo® Processor E4600 (2.40GHz/2MB)

Expansion card (Product ID)

SCSI card (PGB2281L)

PCI slot location

( ) 512 MB ( ) 1 GB ( ) 2 GB

Installation CPU

Thin 5 inches bay Options (Product ID)

Internal DVD-ROM unit [PGBDV106]

Installation RAM module

( ) 512 MB ( ) 1 GB ( ) 2 GB

Installation 3.5 inch internal option

( ) 73.4 GB ( ) 146.8 GB ( ) 300 GB *1( ) 73.4 GB ( ) 146.8 GB ( ) 300 GB *2

LAN card (PG-288L)

( ) 80 GB ( ) 160 GB ( ) 500 GB *2

Installation 3.5 inch internal option

( ) 80 GB ( ) 160 GB ( ) 500 GB *1

LAN card (PGB289L/PG-289L)

( ) 512 MB ( ) 1 GB ( ) 2 GB( ) 512 MB ( ) 1 GB ( ) 2 GB

A Configuration Sheets of Hardware

4

PRIMERGY RX100 S5 Configuration Sheets

Use this form to record the settings of the BIOS Setup Utility. If you have not changed the initial value,put a check mark in parentheses of "The initial values have been unchanged".The initial values in the dotted frame can be changed. If you change any setting, put a check mark inparentheses of the ”Setting” column.Keep the values on the gray zones unchanged.

Follow the procedure below to start the BIOS Setup Utility.

When the following message appears on the screen during POST, press the [F2] key while the

message is displayed. When POST is completed, the Main menu screen appears.

<F2> BIOS Setup/ <F12> Boot Menu

If the system starts before starting the BIOS Setup Utility, press the [Ctrl] + [Alt] + [Delete] keys

simultaneously and restart the system.

( ) The initial values have been unchanged.

Setting

System Time: HH:MM:SS Sets present time.

System Date: MM/DD/YYYY Sets present date.

> SATA Port 1 Links to the SATA Port 1-2 submenu> SATA Port 2 Links to the SATA Port 1-2 submenu> SATA Port 5 Links to the SATA Port 5 submenu

> Boot Features Links to the Boot Features submenu

System Memory: 633KB Displays the Base Memory.(Unchangeable, display only)

Extended Memory: xxxM Displays the Extended Memory.(Unchangeable, display only)

■SATA Port 1-2 Submenu( ) The initial values have been unchanged.

Setting

SATA Port x: [<HDD Device Name>]

Total Sectors: xxxxxxxxxMaximum Capacitry: xxx Gbyte

Multi-Sector Transfers: x SectorsLBA Mode Control: Enabled32 Bit I/O: EnabledTransfer Mode: FPIO x/DMA xUltra DMA Mode: Mode xSMART Monitoring: EnabledFirmware: x.xxx

Display such as device capacity, LBA Mode,DMA transfer mode,version of the firmware.(Unchangeable, display only)

Item Initial value

Item Initial value

B Configuration Sheets of BIOS Setup Utility Parameters

B.1 Parameters in the Main Menu

5

B Configuration Sheets of BIOS Setup Utility Parameters

■SATA Port 5 Submenu( ) The initial values have been unchanged.

Setting

SATA Port x: [<CD/DVD Device Name>]

Multi-Sector Transfers: DisabledLBA Mode Control: Enabled32 Bit I/O: EnabledTransfer Mode: FPIO x/DMA xUltra DMA Mode: Mode xSMART Monitoring: DisabledFirmware: x.xx

■Boot Features Submenu

( ) The initial values have been unchanged.

Setting

Boot Features

POST Errors Enabled ( )DisabledKeyboard Check Enabled ( )DisabledFast Boot: Disabled ( )EnabledPost Diagnostic Screen: Enabled ( )DisabledBoot Menu: Enabled ( )DisabledNumLock: Auto ( )On ( )Off

( ) The initial values have been unchanged.

Setting

Setup WarningSetting items on this menu to incorrect valuesmay cause your system to malfunction

> Peripheral Configuration Links to the Peripheral Configuration submenu

> Advanced System Configuration Links to the Advanced System Configuration submenu

> Advanced Processor Options Links to the Advanced Processor Options submenu

> PCI Configuration Links to the PCI Configuration submenu

Item Initial value

Display such as LBA Mode,DMA transfer mode,version of the firmware.(Unchangeable, display only)

Item Initial value

Item Initial value

B.2 Parameters in the Advanced Menu

6

PRIMERGY RX100 S5 Configuration Sheets

■Peripheral Configuration Submenu

( ) The initial values have been unchanged.

Setting

Peripheral Configuration

Serial 1: Auto ( )Disabled ( )Enabled ( )OS Controlled

Serial 1 Address: *1 3F8h,IRQ 4 ( )2F8h,IRQ 3 ( )3E8h,IRQ 4 ( )2E8h,IRQ 3

Serial Multiplexer: *2 System ( )iRMC

USB Front: Enabled ( )Disabled

USB Rear: Enabled ( )Disabled

USB Devices: All ( )None ( )Keyboard And Mouse Only

LAN Controller: LAN1&LAN2 ( )Disabled ( )LAN2

LAN 1 Oprom: *3 Disabled ( )PXE ( )iSCSI※iSCSI is impossible of a change.(Unsupported)

LAN 2 Oprom: *4 Disabled ( )PXE ( )iSCSI※iSCSI is impossible of a change.(Unsupported)

Management LAN: Enabled ( )Disabled

SAS Controller: *5 Enabled ( )Disabled

SAS Option Rom Scan: *5 Enabled ( )Disabled

■Advanced System Configuration Submenu

( ) The initial values have been unchanged.

Setting

Advanced System Configuration

On board Video: Enabled ( )Disabled

High Precision Event Timer: Disabled ( )Enabled

SMART Device Monitoring: Enabled ( )Disabled

SATA RAID Enabled: Disabled SATA OS installation model :( )Enabled

Enabled SATA RAID(Mega SR) model :( )Disabled

SATA AHCI Enabled: *1 Disabled ( )Enabled

*4:Appears when "LAN1&2" is selected for [LAN Controller].

*5:It is displayed only by SAS model.

*1:It can operate if [SATA RAID Enable] is "Disabled".

*3:Appears when "LAN1" or "LAN1&2" is selected for [LAN Controller].

Item Initial value

Item Initial value

*1:Appears when "Enabled" is selected for [Serial 1].

*2:When Serial Multiplexer is set to "iRMC ", it is necessary to change [Serial 1 ] to "Disabled". When you set Enabled and Port to Serial 1 in Server>Console Redirection>Console Redirection when you set Serial Multiplexer in "System", you must not connect modems to Serial 1.

7

B Configuration Sheets of BIOS Setup Utility Parameters

■Advanced Processor Options Submenu( ) The initial values have been unchanged.

Setting

Advanced Processor Options

CPU Mismatch Detection: Enabled ( )DisabledEnhanced Speed Step: *1 Disabled ( )EnabledCPU Halt Mode: *2 Enhanced ( )StandardEnhanced Idle Power State: *3 Disabled ( )DisabledCPU Thermal Management: Enhanced ( )Standard

Virtualization Technology: *4 Disabled ( )EnabledNX Memory Protection: Disabled ( )Enabled

Adjacent Cache Line Prefetch: Enabled ( )DisabledHardware Prefetc: Enabled ( )Disabled

Core Multi-Processing: *1 Enabled ( )DisabledLimit CPUID Functions: Disabled ( )EnabledCPU MC Status Clear: Next Boot ( )Enabled ( )Disabled

■PCI Configuration Submenu( ) The initial values have been unchanged.

Setting

PCI Configuration

> PCI SLOTS Configuration Links to the PCI SLOTS Configuration submenu

PCI IRQ Line 1 : Auto Select ( )Disabled ( )3 ( )4 ( )5 ( )7 ( )9 ( )10( )11 ( )12 ( )14 ( )15

PCI IRQ Line 2 : Auto Select ( )Disabled ( )3 ( )4 ( )5 ( )7 ( )9 ( )10( )11 ( )12 ( )14 ( )15

PCI IRQ Line 3 : Auto Select ( )Disabled ( )3 ( )4 ( )5 ( )7 ( )9 ( )10( )11 ( )12 ( )14 ( )15

PCI IRQ Line 4 : Auto Select ( )Disabled ( )3 ( )4 ( )5 ( )7 ( )9 ( )10( )11 ( )12 ( )14 ( )15

PCI IRQ Line 5 : Auto Select ( )Disabled ( )3 ( )4 ( )5 ( )7 ( )9 ( )10( )11 ( )12 ( )14 ( )15

PCI IRQ Line 6 : Auto Select ( )Disabled ( )3 ( )4 ( )5 ( )7 ( )9 ( )10( )11 ( )12 ( )14 ( )15

PCI IRQ Line 7 : Auto Select ( )Disabled ( )3 ( )4 ( )5 ( )7 ( )9 ( )10( )11 ( )12 ( )14 ( )15

PCI IRQ Line 8 : Auto Select ( )Disabled ( )3 ( )4 ( )5 ( )7 ( )9 ( )10( )11 ( )12 ( )14 ( )15

■PCI SLOTS Configuration Submenu( ) The initial values have been unchanged.

Setting

PCI SLOTS Configuration

PCI Slot 1 ConfigurationOption ROM SCAN: Enabled ( )Disabled

PCI Slot 2 ConfigurationOption ROM SCAN: Enabled ( )Disabled

Item Initial value

*2:The item is not displayed just after Load Default.Confirm that it is displayed after reboot. It cannot change if Xeon,Core 2 Duo E4600 is installed.

*3:The item is not displayed with Xeon3220,Celeron.

Item Initial value

*1:The item is not displayed with Celeron 430.

Item Initial value

*3:The item is not displayed with Core2 Duo E4600,Celeron 430.

8

PRIMERGY RX100 S5 Configuration Sheets

( ) The initial values have been unchanged.

Setting

Supervisor Password: Not installed Displays whether or not the Supervisor Password is set.

User Password: Not installed Displays whether or not the User Password is set.

Set Supervisor Password: Press Enter Setting of Supervisor Password.Setup Password Lock: *1 Standard ( )Extended Set User Password: *2 Press Enter Setting of User Password.User Password Mode: *3 Standard ( )Extended

Password On boot: *4 Disabled ( )EnabledSystem Password Lock: *5 Standard ( )WOL SKIP

> TPM (Security Chip) Setting Links to the TPM (Security Chip) Setting submenu

Virus Warning: Disabled ( )Enabled ( )Confirm

Diskette Write: *6 Enabled ( )DisabledFlash Write: Enabled ( )Disabled

*1:It will be displayed if Supervisor Password is set.*2:It can set if Supervisor Password is set.

■TPM (Security Chip) Setting Submenu( ) The initial values have been unchanged.

Setting

Security Chip: Disabled ( )Enabled

Current TPM State Disabled andDeactivated

Change TPM State: *1 No Change ( )Enable & Activate ( )Disable & Deactivate ( )Clear

*1:It can set if Security Chip is "Enabled". This setting becomes effective after reboot.

( ) The initial values have been unchanged.

Setting

Power On Source: BIOS Controlled ( )ACPI Controlled Remote: Disabled ( )Enabled LAN: Enabled ( )Disabled Wake Up Timer Disabled ( )Enabled Wake Up Time: *1 [00:00:00]

Wake Up Mode: *1 Daily ( )Monthly

Wake Up day: *2 1 ( )[1-31]

Power Failure Recovery: Previous State ( )Always Off ( )Always On

*1:It can change if [Wake Up Timer] is [Enabled].*2:It can change if [Wake Up Mode] is [Monthly].

Item Initial value

Item Initial value

*3:It will be displayed if Set User Password is set.*4:It can set if User Password is set.*5:It can set if Password on boot is "Enabled".*6:It is invalid in USB Device.

Item Initial value

B.4 Parameters in the Power menu

B.3 Parameters in the Security menu

9

B Configuration Sheets of BIOS Setup Utility Parameters

( ) The initial values have been unchanged.

Setting

O/S Boot Timeout: Disabled ( )Enabled Action: Reset ( )Continue ( )Power Cycle Timeout Value: 0 ( )[1~100]

ASR&R Boot Delay: 2 ( )[1~30]

Power Cycle Delay: 7 ( )[0~15]

Temperature Monitoring: Disabled ( )Enabled

Boot Retry Counter: 3 ( )[0~7]

> CPU Status Links to the CPU Status submenu> Memory Status Links to the Memory Status submenu> PCI Status Links to the PCI Status submenu> Console Redirection Links to the Console Redirection submenu> IPMI Links to the IPMI Status submenu

■CPU Status Submenu

( ) The initial values have been unchanged.

Setting

CPU Status

CPU Status: Enabled ( )Failed ( )Disabled ( )Empty *1

■Memory Status Submenu( ) The initial values have been unchanged.

Setting

Memory Status

DIMM-1A: Enabled ( )Failed ( )Disabled ( )Empty *1DIMM-2A: Empty ( )Failed ( )Disabled ( )Enabled *1DIMM-1B: Empty ( )Failed ( )Disabled ( )Enabled *1DIMM-2B: Empty ( )Failed ( )Disabled ( )Enabled *1

■PCI Status Submenu( ) The initial values have been unchanged.

Setting

PCI Status

Slot 1: Empty ( )Failed ( )Enabled *1

Slot 2: Empty ( )Failed ( )Enabled *1

*1:This can be changed to "Enabled" only (The cases that Memory did Disable, Fail of). All Slot is changed in Enable when I carry out Load default. Slot which is not implemented by a next reboot is changed in Empty.

*1:This can be changed to "Enabled" only (The cases that Memory did Disable, Fail of). All Slot is changed in Enable when I carry out Load default. Slot which is not implemented by a next reboot is changed in Empty.

Item Initial value

Item Initial value

Item Initial value

Item Initial value

*1:This can be changed to "Enabled" only (The cases that Memory did Disable, Fail of). All Slot is changed in Enable when I carry out Load default. Slot which is not implemented by a next reboot is changed in Empty.

B.5 Parameters in the Server menu

10

PRIMERGY RX100 S5 Configuration Sheets

■Console Redirection Submenu

( ) The initial values have been unchanged.

Setting

Console Redirection

Console Redirection: Disabled ( )On-board COM ABaud Rate: 9600 ( )300 ( )1200 ( )2400 ( )19.2K ( )38.4K

( )57.6K ( )115.2K

Console Type: VT100+ ( )VT100 ( )VT100,8bit ( )PC-ANSI,7bit( )PC-ANSI ( )VT-UTF8

Flow Control: CTS/RTS ( )None ( )XON/XOFFContinue C.R. after POST: On ( )Off

■IPMI Submenu( ) The initial values have been unchanged.

Setting

IPMI

SM Error Halt: Enabled ( )DisablediRMC Time Sync: Enabled ( )DisabledClear System Event Log: *1 Disabled ( )EnabledEvent Log Full Mode: Overwrite ( )Maintain

Date Format to show: MM DD YYYY ( )DD MM YYYY ( )YYYY MM DDDate Separator: / ( ).

> System Event Log Displays the log saved on SEL.Pressing the [+] [-] keys changes the entries.

> System Event Log(List mode) Displays the log saved on SEL.The event logs are displayed in a list.

> Realtime Sensor Data Confirms the sensor information.

> LAN Settings Links to the LAN Settings Submenu

> IPMI Status Links to the IPMI Status Submenu

*1:When SEL is not done save of, it is not displayed.

■LAN Settings Submenu

( ) The initial values have been unchanged.

Setting

LAN Settings

Service LAN: Enabled ( )DisabledService LAN Port: *1 Service ( )SharedDHCP: *2 Disabled ( )EnabledLocal IP address: *2 *3 [000.000.000.001] IP address of iRMC

[ . . . ]

Subnet mask: *2 [000.000.000.000] Subnet mask[ . . . ]

Gateway address: *2 [000.000.000.000] Gateway address[ . . . ]

*1:Appears when "Enabled" is selected for [Service LAN].

*2:Keep the value in previous set after perform Load Default.*3:When DHCP is set to "Disabled", Local IP Address cannot be set to [000.000.000.000].

Item Initial value

Item Initial value

Item Initial value

11

B Configuration Sheets of BIOS Setup Utility Parameters

■IPMI Status Submenu( ) The initial values have been unchanged.

IPMI Status

IPMI Specification Version: Display the version of IPMI (Unchangeable, display only)

BMC Hardware/Firmware Version:

Display the firmware version of iRMC (Unchangeable, display only)

SDRR Version: Display the version of SDRR (Unchangeable, display only)

SEL Load: The loaded percentage on the SELExisting Event Log number: Display the entries number of SEL (Unchangeable, display only)

Remaining Event Log number: Displays SEL free space(Unchangeable, display only)

■Boot menuSetting

Boot priority order:

1: IDE CD:CD Device name 2: IDE x:HDD Device name *1 3: 4: 5: 6: 7: 8:Excluded from boot order:

:Legacy Network Card

:Bootable Add-in Cards

*1:The name of HDD devices on the display vary as below.

ModeNativeMegaSR(SATA)

SAS-RAID(Onboard)

*2:The name of Onboard LAN devices on the display vary as below by setting of LAN * Oprom.

ModeLAN1LAN2

*3:The name of CD-ROM devices on the display vary as below.

ModeMegaSR(SATA) or AHCISAS、Native

Save Changes & Exit:

Discard Changes & Exit:

Get Default Values:

Load Previous Values:

※1:IPMI-LAN Setting value is retained previous setting value.※2:If Get Default Value is performed while USB-FDD drive is connected, it's moved to Excluded from boot order.

If starting the system from the FDD, re-setting is required.

Item

Item

Item

iRMC Firmware Version:

Initial value Setting

PCI BEV:Boot Manage PXE,Slot 0520 *2PCI BEV:Boot Manage PXE,Slot 0521 *2

Returns to the default values of the server for all items.

Sets all items to the values before the last changes by readingfrom CMOS.

Exits BIOS Setup Utility without saving current settings to CMOS.

Saves the current settings to CMOS and exit BIOS Setup Utility.

Initial value Setting

Display the hardware and firmware version of BMC(Unchangeable, display only)

Initial value

on the displayIDE: Device namePCI SCSI: ICHx/ESB2 Embedded RAID

PCI SCSI: #0300 ID00 LUN0 LSILOGIC L

PCI BEV: Device nameIDE: Device name

on the displayPXE: PCI BEV: Boot Manage PXE, Slot xxxxPXE: PCI BEV: Boot Manage PXE, Slot xxxx

on the display

B.6 Parameters in the Boot menu

B.7 Parameters in the Exit menu

12

PRIMERGY RX100 S5 Configuration Sheets

Use this form to record the settings of the Remote Management Controller Webinterface. If you have not change the initial value, put a check mark in parentheses of"The initial values have been unchanged".The initial values in the dotted frame can be changed.

( ) The initial values have been unchanged.

Setting

iRMC S2 Information Displays iRMC information.Firmware Information

Firmware Selector Auto - FW Imagewith highest FWversion

Unchangeable

( )Auto - EEPROM with highest FW version( )Low EEPROM( )High EEPROM( )Select with olest FW version( )Select most recently programmed FW( )Select least recently programmed FW

License Key License Key (Not displayed input data.)

Upload Not Upload ( )Not Upload ( )Upload

Certificate UploadCertificate Upload

CA Certificate upload from file CA Certificate instandard iRMC

( )Not Upload ( )UploadUnsupported

SSL Certificate and DSA/RSAprivate key upload from file

Certificate instandard iRMC

( )SSL Private Key File( )Certificate File

Please paste your DSA certificateor DSA private key into the textarea below!

Certificate instandard iRMC

enter the inside box

Generate Certificate

Common Name (CN) DNS setting value [ ]

Organization Name (O) iRMC S2 [ ]

Organizational Unit Name (OU) [ ]

Country Name (C) [ ]

State or Province Name (ST) [ ]

Locality Name (L) [ ]

Email Address [ ]

Valid for [days] 730 [ ]

Key Length [bits] 1024 ( ) 512 ( ) 1024

Item Initial value

C Configuration Sheets of Remote Management Controller's Web interface

C.1 Parameters in the iRMC S2

13

C Configuration Sheets of Remote Management Controller's Web Interface

( ) The initial values have been unchanged.

Setting

Power On/Off

Boot Options

Error Halt Settings BIOS setting isreflected

( )Halt on errors ( )Continue

Boot Device Selector No change ( )PXE/iSCSI ( )Hard-drive( )CDROM/DVD ( )Froppy

Power Options

Power Restore Pollicy

BIOS setting is ( )Always Power offreflected ( )Always Power on

( )Restore to powered state prior to power loss

Power On/Off Time Sets schedule On/Off time.

None On Time[   ] Off Time[   ] Sunday

None On Time[   ] Off Time[   ] Monday

None On Time[   ] Off Time[   ] Tuesday

None On Time[   ] Off Time[   ] Wednesday

None On Time[   ] Off Time[   ] Thursday

None On Time[   ] Off Time[   ] Friday

None On Time[   ] Off Time[   ] Saturday

None On Time[   ] Off Time[   ] Everyday

Item Initial value

C.2 Parameters in the Power Management

14

PRIMERGY RX100 S5 Configuration Sheets

( ) The initial values have been unchanged.

Setting

Power consumption configuration

Power Consumption Options controll the power consumption

Power Control Mode Power Mgmt. DisabledUnchangeable withoutBIOS setting

( )Best Performance ( )Minimum Power( )Scheduled

Appears when "Scheduled" is selected for [PowerControl Mode].

Sunday Time[HH:MM] no valueMode:   Power Mgmt. Disabled

Time1 [ ] Mode1 ( )Power Mgmt. Disabled ( )Best Performance ( )Minimum PowerTime2 [ ] Mode2 ( )Power Mgmt. Disabled ( )Best Performance                  ( )Minimum Power

Monday Time[HH:MM] no valueMode:   Power Mgmt. Disabled

Time1 [ ] Mode1 ( )Power Mgmt. Disabled ( )Best Performance ( )Minimum PowerTime2 [ ] Mode2 ( )Power Mgmt. Disabled ( )Best Performance                  ( )Minimum Power

Tuesday Time[HH:MM] no valueMode:   Power Mgmt. Disabled

Time1 [ ] Mode1 ( )Power Mgmt. Disabled ( )Best Performance ( )Minimum PowerTime2 [ ] Mode2 ( )Power Mgmt. Disabled ( )Best Performance                  ( )Minimum Power

Wednesday Time[HH:MM] no valueMode:   Power Mgmt. Disabled

Time1 [ ] Mode1 ( )Power Mgmt. Disabled ( )Best Performance ( )Minimum PowerTime2 [ ] Mode2 ( )Power Mgmt. Disabled ( )Best Performance                  ( )Minimum Power

Thursday Time[HH:MM] no valueMode:   Power Mgmt. Disabled

Time1 [ ] Mode1 ( )Power Mgmt. Disabled ( )Best Performance ( )Minimum PowerTime2 [ ] Mode2 ( )Power Mgmt. Disabled ( )Best Performance                  ( )Minimum Power

Friday Time[HH:MM] no valueMode:   Power Mgmt. Disabled

Time1 [ ] Mode1 ( )Power Mgmt. Disabled ( )Best Performance ( )Minimum PowerTime2 [ ] Mode2 ( )Power Mgmt. Disabled ( )Best Performance                  ( )Minimum Power

Saturday Time[HH:MM] no valueMode:   Power Mgmt. Disabled

Time1 [ ] Mode1 ( )Power Mgmt. Disabled ( )Best Performance ( )Minimum PowerTime2 [ ] Mode2 ( )Power Mgmt. Disabled ( )Best Performance                  ( )Minimum Power

Power History Units Watt ( )Watt ( )BTU/h

Power History Period 1 hour ( )1 hour ( )12 hours ( )1 day ( )1 week( )2 weeks ( )1 month ( )1 year

Enable Power Monitoring check-mark ( )Enabled ( )Disabled

Power History Options

Item Initial value

Scheduled Power ConsumptionConfiguration

Power Consumption History

C.3 Parameters in the Power Consumption

15

C Configuration Sheets of Remote Management Controller's Web Interface

( ) The initial values have been unchanged.

Setting

Fan Test Sets Fan Test time.23:00 [ ] HH:MM

Analog Fans Sets the operation at the Fan malfunction.

continue ( )shutdown-and-power-off Deley[ ]sec

continue ( )shutdown-and-power-off Deley[ ]sec

continue ( )shutdown-and-power-off Deley[ ]sec

continue ( )shutdown-and-power-off Deley[ ]sec

continue ( )shutdown-and-power-off Deley[ ]sec

continue ( )shutdown-and-power-off Deley[ ]sec

continue ( )shutdown-and-power-off Deley[ ]sec

( ) The initial values have been unchanged.

Setting

Temperature Sensor Information Sets the operation at the temperaturemalfunction.

continue ( )shutdown-and-power-off

continue ( )shutdown-and-power-off

continue ( )shutdown-and-power-off

( ) The initial values have been unchanged.

Setting

System Event Log Content Displays System Event Log

Enabled ( )Enabled ( )Disabled

Enabled ( )Enabled ( )Disabled

Disabled ( )Enabled ( )Disabled

Disabled ( )Enabled ( )Disabled

Disabled ( )Enabled ( )Disabled

System Event Log Configuration

Default Web interface display filtering

Display Critical Enabled ( )Enabled ( )Disabled

Display Major Enabled ( )Enabled ( )Disabled

Display Minor Disabled ( )Enabled ( )Disabled

Display Info Disabled ( )Enabled ( )Disabled

CSS only Disabled ( )Enabled ( )Disabled

SEL Type Ring SEL ( )Ring SEL   ( )IPMI SEL

2 FAN3 SYS

3 FAN4 SYS

4 FAN5 SYS

Initial value

Display Critical

Display Major

Item Initial value

Item Initial value

Fan Check Time

0 FAN1 SYS

1 FAN2 SYS

Display Info

CSS only

0 Ambient

1 Systemboard

2 CPU 1

Item

5 FAN1 PSU

6 FAN2 PSU

Display Minor

C.5 Parameters in the Temperature

C.4 Parameters in the Fans

C.6 Parameters in the System Event Log

16

PRIMERGY RX100 S5 Configuration Sheets

( ) The initial values have been unchanged.

Setting

ASR&R Options

BIOS setting isreflected

[   ]minutes

BIOS setting isreflected

[   ]

Disabled ( )Disabled   ( )Enabled

BIOS setting isreflected

[   ]seconds

Watchdog Settings BIOS setting isreflected for Boot

Sets Watchdog

Disabled ( )Enabled

Continue ( )Continue ( )Reset  ( )Power Cycle

timeout delay: [   ]minutes

Disabled ( )Enabled

Continue ( )Continue ( )Reset ( )Power Cycle

timeout delay: [   ]minutes

HP SIM Integration Disabled Disabled ( )Enabled

Item Initial value

HP System Insight Manager (HP SIM) Integration Options

Boot Watchdog:

Software Watchdog:

Power Cycle Delay

BIOS recovery flash bit

Retry counter

ASR & R Boot Delay

C.7 Parameters in the Server Management Information

17

C Configuration Sheets of Remote Management Controller's Web Interface

( ) The initial values have been unchanged.

Setting

EthernetIP configuration

MAC Address Displays MAC address of iRMC.LAN Speed Auto Negotiation ( )Auto Negotiation

( )100MBit/s Full Duplex( )100MBit/s Half Duplex( )10MBit/s Full Duplex( )10MBit/s Half Duplex

LAN Port Service LAN ( )Service LAN( )Shaerd LAN

IP Address BIOS setting is reflected [ . . . ]

Subnet Mask BIOS setting is reflected [ . . . ]

Gateway BIOS setting is reflected [ . . . ]

DHCP enable BIOS setting is reflected ( )Enabled ( )Disabled

VLAN configuration

VLAN enable Disabled ( )EnabledVLAN Id 0 [ ]1 - 4094

VLAN Priority 0 [ ]0 - 7

Ports and Network Services

Session timeout 300 [       ]

HTTP Port 80 [       ]

HTTPS Port 443 [       ]

Force HTTPS Disabled ( )Enabled ( )DisabledEnable Auto Refresh Enabled ( )Enabled ( )DisabledRefresh every xxx seconds 120 [ ]

Text based accsess

Telnet Port 3172 [       ]

Telnet Drop Time 600 [       ]

SSH Port 22 [       ]

Telnet enabled Disabled ( )Enabled ( )Disabled

Standard Port (via HTTP) same as HTTP Port work with HTTP Port

Secure Port (via HTTPS) sane as HTTPS Port work with HTTPS Port

Standard Port 5901 [       ]

DHCP Configuration

Register DHCP Address in DNS Enabled ( )Enabled ( )Disabled

Use iRMC Name instead of Hostname Enabled ( )Enabled ( )Disabled

Add Serial Number Enabled ( )Enabled ( )Disabled

Add Extension Disabled ( )Enabled ( )Disabled

iRMC Name IRMC [       ]

Extension -iRMC [       ]

DNS Settings

DNS enabled Enabled ( )Enabled ( )DisabledObtain DNS configuration from DHCP Enabled ( )Enabled ( )Disabled

DNS Domain domain.com [                ]

DNS Server1 0.0.0.0 [ . . . ]

DNS Server2 0.0.0.0 [ . . . ]

DNS Server3 0.0.0.0 [ . . . ]

DNS Server4 0.0.0.0 [ . . . ]

DNS Server5 0.0.0.0 [ . . . ]

Remote Storage Ports

Item Initial value

Web based access

VNC Ports

C.8 Parameters in the Network Settings

18

PRIMERGY RX100 S5 Configuration Sheets

( ) The initial values have been unchanged.

Setting

SNMP Trap Destination

SNMP Community public [ ]

SNMP Server1 0.0.0.0 [ ]

SNMP Server2 0.0.0.0 [ ]

SNMP Server3 0.0.0.0 [ ]

SNMP Server4 0.0.0.0 [ ]

SNMP Server5 0.0.0.0 [ ]

SNMP Server6 0.0.0.0 [ ]

SNMP Server7 0.0.0.0 [ ]

( ) The initial values have been unchanged.

Setting

Global Email Paging Configuration

Email Alerting Enable Disabled ( )Enabled

SMTP Retries 3 [ ]

SMTP Retry Delay 240 [ ]

SMTP Response Timeout 45 [ ]

Primary SMTP Server Configuration

SMTP Server 0.0.0.0 [ ]

SMTP Port 25 [ ]

Auth Type None ( )None ( )SMTP AUSH(RFC2554)

 Auth UserName *1 [ ]

 Auth Password *1 *Displays

 Confirm Password *1 *Displays

Secondary SMTP Server Configuration

SMTP Server 0.0.0.0 [ ]

SMTP Port 25 [ ]

Auth Type None ( )None ( )SMTP AUSH(RFC2554)

 Auth UserName *1 [ ]

 Auth Password *1 *Displays

 Confirm Password *1 *Displays

Mail Format dependend Configuration

From [email protected] [ ]

Subject FixedMailSubject [ ]

Message FixedMailMessage [ ]

Admin. Name ITS_UserInfo0 [ ]

Admin. Phone ITS_UserInfo1 [ ]

REMCS Id Unchangeable

Server URL http://www.server.com [ ]

*1:Appears when "SMTP AUTH(RFC 2554)" is selected for [Auth Type].

Item Initial value

Item Initial value

C.10 Parameters in the Email Alerting

C.9 Parameters in the SNMP Trap Alerting

19

C Configuration Sheets of Remote Management Controller's Web Interface

( ) The initial values have been unchanged.

Setting

iRMC User Information

ID/Name 2 admin 2   [ ]

None 3   [ ]

None 4   [ ]

None 5   [ ]

None 6   [ ]

None 7   [ ]

None 8   [ ]

None 9   [ ]

None 10   [ ]

None 11   [ ]

None 12   [ ]

None 13   [ ]

None 14   [ ]

None 15   [ ]

None 16   [ ]

The User Name is displayed that is created by [New User]. Clicking "UserName" displays a settingwindow for each UserName.The default settings or the settings that are configured when creating a new user are displayed on thesetting window. The setting is available up to user number 15th. (Unable to set at user number 1.)

Item Initial value

C.11 Parameters in the User Management

20

PRIMERGY RX100 S5 Configuration Sheets

■User "admin(2)" Configuration

( ) The initial values have been unchanged.

Setting

Access InformationUser Enabled Enabled ( )Disabled ( )Enabled

Name admin [ ]

Password *DisplaysConfirm Password *Enter the password again to confirm it.

User Description User02 Description [ ]

User Shell Remote Manager ( )SMASH CLP( )Remote Manager( )IPMI Basic Mode( )IPMI Terminal Mode( )None

Privilege / Shell

IPMI LAN Privilege OEM ( )User ( )Operater ( )Administorator( )OEM

IPMI Serial Privilege OEM ( )User ( )Operater ( )Administorator( )OEM

Configure User Accounts Enabled ( )Disabled ( )Enabled

Configure iRMC settings Enabled ( )Disabled ( )Enabled

Video Redirection enabled Enabled ( )Disabled ( )Enabled

Remote Storage enabled Enabled ( )Disabled ( )Enabled

Email Configuration

Email Enabled Disabled ( )Disabled ( )Enabled

Mail Format Standard ( )Standard ( )Fixed Subject

( )ITS Format ( )Fujitsu REMCS-Format

Prefered Mail Server Automatic ( )Automatic ( )Primary ( )Secondary

Email Address [email protected] [ ]

Fan Sensors WARNING ( )NONE ( )CRITICAL ( )WARNING ( )ALL

Temperature Sensors WARNING ( )NONE ( )CRITICAL ( )WARNING ( )ALL

Critical Hardware Errors ALL ( )NONE ( )CRITICAL ( )WARNING ( )ALL

System Hang CRITICAL ( )NONE ( )CRITICAL ( )WARNING ( )ALL

POST Errors ALL ( )NONE ( )CRITICAL ( )WARNING ( )ALL

Security WARNING ( )NONE ( )CRITICAL ( )WARNING ( )ALL

System Status NONE ( )NONE ( )CRITICAL ( )WARNING ( )ALL

Disk Drivers & Controllers CRITICAL ( )NONE ( )CRITICAL ( )WARNING ( )ALL

Network Interface WARNING ( )NONE ( )CRITICAL ( )WARNING ( )ALL

Remote Management CRITICAL ( )NONE ( )CRITICAL ( )WARNING ( )ALL

System Power WARNING ( )NONE ( )CRITICAL ( )WARNING ( )ALL

Memory CRITICAL ( )NONE ( )CRITICAL ( )WARNING ( )ALL

Others NONE ( )NONE ( )CRITICAL ( )WARNING ( )ALL

Item Initial value

This is the UserName setting window for user ID 2.The user ID 2 (admin) is the UserName/ID as initial value.

21

C Configuration Sheets of Remote Management Controller's Web Interface

■ User "    ( )" Configuration

( ) The user is not newly created.

Setting

Access Information

User Enabled Setting at creatinga new user

( )Disabled ( )Enabled

Name Setting at creatinga new user

[ ]

Password Setting at creatinga new user

*Displays

Confirm Password *Enter the password again to confirm it.

User Description Setting at creatinga new user

[ ]

User Shell Setting at creatinga new user

( )SMASH CLP( )Remote Manager( )IPMI Basic Mode( )IPMI Terminal Mode( )None

Privilege / Shell

IPMI LAN Privilege Setting at creatinga new user

( )User ( )Operater ( )Administorator( )OEM

IPMI Serial Privilege Setting at creatinga new user

( )User ( )Operater ( )Administorator( )OEM

Configure User Accounts Setting at creatinga new user

( )Disabled ( )Enabled

Configure iRMC settings Setting at creatinga new user

( )Disabled ( )Enabled

Video Redirection enabled Setting at creatinga new user

( )Disabled ( )Enabled

Remote Storage enabled Setting at creatinga new user

( )Disabled ( )Enabled

Email Configuration

Email Enabled Disabled ( )Disabled ( )Enabled

Mail Format Standard ( )Standard ( )Fixed Subject( )ITS Format ( )Fujitsu REMCS-Format

Prefered Mail Server Automatic ( )Automatic ( )Primary ( )Secondary

Email Address [ ]

Fan Sensors WARNING ( )NONE ( )CRITICAL ( )WARNING ( )ALL

Temperature Sensors WARNING ( )NONE ( )CRITICAL ( )WARNING ( )ALL

Critical Hardware Errors ALL ( )NONE ( )CRITICAL ( )WARNING ( )ALL

System Hang CRITICAL ( )NONE ( )CRITICAL ( )WARNING ( )ALL

POST Errors ALL ( )NONE ( )CRITICAL ( )WARNING ( )ALL

Security WARNING ( )NONE ( )CRITICAL ( )WARNING ( )ALL

System Status NONE ( )NONE ( )CRITICAL ( )WARNING ( )ALL

Disk Drivers & Controllers CRITICAL ( )NONE ( )CRITICAL ( )WARNING ( )ALL

Network Interface WARNING ( )NONE ( )CRITICAL ( )WARNING ( )ALL

Remote Management CRITICAL ( )NONE ( )CRITICAL ( )WARNING ( )ALL

System Power WARNING ( )NONE ( )CRITICAL ( )WARNING ( )ALL

Memory CRITICAL ( )NONE ( )CRITICAL ( )WARNING ( )ALL

Others NONE ( )NONE ( )CRITICAL ( )WARNING ( )ALL

Item Initial value

This is the UserName setting window for user ID 3 to 16.The user ID 3 to 16 have same settings as initial value. Copy this sheet when two or more users are created.

22

PRIMERGY RX100 S5 Configuration Sheets

( ) The initial values have been unchanged.

Setting

Directory Service Configuration

Global Directory Service Configuration

LDAP Enable Disabled ( )Disabled ( )EnabledLDAP SSL Enable Disabled ( )Disabled ( )EnabledDisable Local Login ¹ Disabled ( )Disabled ( )Enabled

Always use SSL Login Disabled ( )Disabled ( )Enabled

Directory Server Type Active Directory ( )ActiveDirectory ( )Novel ( )OpenLDAP

LDAP Server 1 0.0.0.0 [ ]LDAP Server 2 0.0.0.0 [ ]Domain name domain.com [ ] Base DN *Only displayedDept. name department [ ]

Directory Service Access Configuration

LDAP Auth UserName LDAPuserName [ ]

LDAP Auth Password ************ [ ]displays as "*".

Confirm Password *Enter the password again to confirm it.

( ) The initial values have been unchanged.

Setting

BIOS setting isreflected

Console Redirection Enabled ( )Disabled  ( )Enabled

Console Redirection Mode ( )Standard ( )Enhanced

Console Redirection Port ( )COM1 ( )COM2

Serial Port Baudrate ( )1200 ( )2400 ( )4800 ( )9600( )19200 ( )38400 ( )57600 ( )115200

Serial Port Flow Control ( )None ( )XON/XOFF ( )CTS/RTS

Terminal Emulation ( )VT100 7Bit ( )VT100 8Bit ( )PC-ANSI 7Bit

( )PC-ANSI 8Bit ( )VT100+ ( )VT-UTF8

Serial 1 Multiplexer ( )System ( )iRMC

( ) The initial values have been unchanged.

Setting

Enable Local Monitor Off Disabled ( )Enabled  ( )Disabled

Automatic Local Monitor Offwhen AVR is started

Disabled ( )Enabled  ( )Disabled

Local Monitor Switch button Always On ( )AlwaysOn ( )Turn Off ( )Turn On

Item Initial value

*1:[Cautions] Under the setting of valid LDAP and unusable directry server, it is impossible to log-in to the Web interface if this setting is valid. Novel eDirectory and OpenLDAP are not supported.

Local Monitor

The Local Monitor Switch button cannot be changed from Always On, if Enable Local Monitor Off isdisabled; it can be changed between Turn Off and Turn On, if Enable Local Monitor Off is enabled.

BIOS Console RedirectionOptions

Item Initial value

Item Initial value

C.13 Parameters in the BIOS Text Console

C.14 Parameters in the Advanced Video Redirection

C.12 Parameters in the LDAP Configuration

23

D Design Sheet of the RAID Configuration

Use this form to record the definitions of the disk groups (or the physical packs) andthe logical drives in the RAID configuration (array configuration).

■Content of Definition of the Logical Drive

HDD modelname

HDDcapacity

Logical drive capacity

(e.g.) Bay 1 PG-HDB75A 73.4GB 69618 MB

(e.g.) Bay 2 PG-HDB75A 73.4GB 69618 MB

Bay 1

Bay 2

■Content of Definition of the Logical Drive

HDD modelname

HDDcapacity

Logical drive

(e.g.) Bay 1 PG-HDF67B 160GB Logical drive [0]

(e.g.) Bay 2 PG-HDF67B 160GB Logical drive [0]

Bay 1 Logical drive [ ]

Bay 2 Logical drive [ ]

RAID levelLogical drive

capacity

(e.g.) LD : 0( )RAID 0( )RAID 1

151634 MB

(e.g.) LD : 1( )RAID 0( )RAID 1

151634 MB

LD :( )RAID 0( )RAID 1

LD :( )RAID 0( )RAID 1

InstallationHDD Slot / Bay

Logical drive No.(LD No.)

InstallationHDD Slot / Bay

D Design Sheet of the RAID Configuration

D.1 For Integrated Mirroring SAS

D.2 For Embedded MegaRAID SATA

24

PRIMERGY RX100 S5 Configuration Sheets

When setting up the server using ServerStart, select the setting values and put a check mark in parentheses below in advance to ensure setup is performed smoothly.

Setting

( ) Logical Drive View   (The system will be used as it is, with the current RAID configuration)

( ) Mass Storage Controller View   (The RAID configuration can be specified)

( ) RAID      ( ) SCSI( ) Fibrechannel    ( ) IDE

( ) Automatically  ( ) Manually

( ) Delete Existing RAID Array

RAID Level

Number of Disks

( ) NTFS       ( ) FAT

( ) Auto setting ( )          MB

( ) Execute ( ) Do not execute

( ) Boot ( ) OS      ( ) Data

Disk ↓Make copies when installing multiple disks.

Partition ↓Make copies when more sheets are needed.

Volume label

File system

Partition size

Quick format

Partition Usage

Controller Number

Configure RAID:

Manually

Parameters

Controller

When you select "RAID" with controller's typeConfigure RAID

Existing RAID ArrayController Vendor

E Design Sheet

E.1 RAID/Disk Wizard

25

E Design Sheet

Setting

When selecting Windows Server 2003/R2 to install( ) Windows Server 2003, Standard Edition( ) Windows Server 2003 R2, Standard Edition

Windows Server 2003 x64/R2 to install( ) Windows Server 2003, Standard x64 Edition( ) Windows Server 2003 R2, Standard x64 Edition

( ) no service pack( ) ServicePack1 applied( ) ServicePack2 applied

( ) Number of connected devices or Number of connected users( ) Concurrent users

(Only when concurrent users are selected)

( ) a work group ( ) a domain

(Default - MYUSERGROUP)

( ) Operating system source media in Available in local CD-ROM drive( ) Operating system source media in Available on a remote share

( ) Install Windows Server 2003 R2 Components

( ) R2 Components source media is available in local CD-ROM drive( ) R2 Components source media is available on a remote share

(Default -(GMT+01:00) Amsterdam, Berlin,Bern, Rome, Stockholm, Vienna)

( ) Use default ( ) Drive Letter

( ) C: ( ) D: ( ) E: ( ) F: ( ) G: ( ) H: ( ) I: ( ) J:( ) K: ( ) L: ( ) M: ( ) N: ( ) O: ( ) P: ( ) Q: ( ) R:( ) S: ( ) T: ( ) U: ( ) V: ( ) W: ( ) X: ( ) Y: ( ) Z:

( ) Use default ( ) Specify in advance

(Default - \winnt)

( ) ― ― ― ―

Remote UsernameReote Password

(continued)

When selecting drive name

Installation Directory

Installation destination

Installation Directory and Time zone

Time Zone

Installation Drive

Installation method

To install Windows Server2003 R2 Components

When you install it from a remote shareRemote Source

Remote Password

Installation method

when installing OS from remote shareRemote Source Path

Password

User account to create computer account (only when Domain is selected)User account

Remote Username

Operating System Type

Parameters

Install Windows 2003Password for Administratoraccount

Computer Identification

Workgroup or Domain Name

ServicePack(SP)

User permitted

will participate in

License Mode

User NameUser NameOrganization

Product-IDComputer Name

E.2 OS Wizard (Windows 2003 Install Wizard)

26

PRIMERGY RX100 S5 Configuration Sheets

Setting

( ) 640 * 480 ( ) 800 * 600  ( ) 1024 * 768( ) 1156 * 864 ( ) 1280 * 1024   ( ) 1600 * 1200( ) 60 ( ) 70 ( ) 72 ( ) 75 ( ) 80 ( ) 85 ( ) 100

( ) 16 colors    ( ) 256 colors   ( ) High Color(16bits)( ) True Color(24bits)   ( ) True Color(32bits)

( ) Install Unattended( ) Install Manually

( ) TCP/IP ( ) NWIPX ( ) NetBEUI ( ) Apple Talk( ) DLC ( ) NetMon ( ) PPTP( ) Use DHCP

IP-AddressSubnet MaskDefault GatewayIP address (additional) (only when added)

Subnet mask (additional) (only when added)

Default gateway (additional) (only when added)

DNS domain name (only when specified)

DNS server address (only when specified)

Use WINS ( ) UseWINS server address DHCP (only when selected to use)

( ) Use NetBIOS setting from the DHCP Server( ) Use NetBIOS over TCP/IP( ) Do not use NetBIOS over TCP/IP

Internal network number 0xNetwork number 0xFrame type

( ) TCP/IP ( ) NWIPX ( ) NetBEUI ( ) Apple Talk( ) DLC ( ) NetMon ( ) PPTP( ) Use DHCP

IP AddressSubnet MaskDefault GatewayIP address (additional) (only when added)Subnet mask (additional) (only when added)Default gateway (additional) (only when added)DNS domain name (only when specified)DNS server address (only when specified)Use WINS ( ) UseWINS server address DHCP (only when selected to use)

( ) Use NetBIOS setting from the DHCP Server( ) Use NetBIOS over TCP/IP( ) Do not use NetBIOS over TCP/IP

Internal network number 0xNetwork number 0xFrame type

(continued)

NetBIOS Option

Adap

ter 1

Connection name

BitsPerPel

Network protocol

Installation method

Network protocol property (for auto-installation)

Do n

ot u

se DH

CP

Parameters

Available Protocols

Use of DHCP (When TCP/IP selected)

Display settings

Resolution

Vrefresh

Copy this sheet to install multiple adapters.

Only when NWIPX is selected

Adap

ter 2

Connection nameProtocol binding to thisadapterUse of DHCP (When TCP/IP selected)

Do n

ot u

se DH

CP

NetBIOS Option

Only when NWIPX is selected

27

E Design Sheet

Setting

( ) Install default Components( ) Install customized Components

( ) R2 Components

( ) Application Mode(ADAM)

( ) Claims-Aware Applications( ) Traditional Applications( ) Federation Service( ) Federation Service Proxy

( ) DFS Management( ) DFS Replication Service

( ) Management Console

( ) User Name Mapping( ) Microsoft Services for NFS Administration( ) Client for NFS( ) Server for NFS( ) RPC Portmapper( ) RPC External Data Representation( ) Server For NFS Authentication

( ) Administration Components( ) Password Synchronisation( ) Server For NIS

Enable Windows Sharepoint Services

( ) Common Log File System( ) Microsoft .NET Framework2.0(English)( ) Microsoft .NET Framework2.0(International)( ) Microsoft .NET Framework2.0 Languagepack( ) Print Management Console( ) Storage Manager SAN( ) Storage Ressource Manager( ) Windows Subsystem for UNIX based Applications

( ) uninstall hidden CFSCommonUIFX( ) uninstall hidden DFSExt( ) uninstall hidden DFSRHelper( ) uninstall set of files from FileServerManagement Console

Uninstall Componennts

(continued)

Microsoft Services for NFS

Unix Identity Management

Windows SharePoint Services

Additional Components

Only when selecting R2 components to install

Active Directory

Distributed File System

File Server

Software Components

Select installation method

R2

Parameters

28

PRIMERGY RX100 S5 Configuration Sheets

Setting

Accessories

( ) clipboard viewer( ) Desktop Wallpaper( ) Document Template( ) Paint( ) All available mousepointers( ) Word pad( ) Calculator( ) Character Map

Accessibility Wizard ( ) Install

Communications( ) Chat( ) Hyper Terminal

ASP.NET webdevelopment platform

( ) Install

Application server console ( ) Install

Internet informationservices(IIS)

( ) FrontPage 2002 Server Extensions( ) FTP (File Transfer Protocol) service( ) NNTP Service - NNTP Service( ) SMTP Service - SMTP Service( ) World Wide Web Server - Internet Information Services ASP support( ) World Wide Web Server - Internet Information Services web DAV publishing

( ) World Wide Web Server - World Wide Web (WWW) Service( ) World Wide Web Server - Internet Information Services internet data connector( ) World Wide Web Server - Internet Information Services web user interface

network COM + access ( ) InstallDTC network access ( ) Install

( ) Install( ) Install( ) Install( ) Install( ) Install  ( ) Server components of the Certificate Services( ) Web client component of the Certificate Services( ) Install  ( ) POP3 main service( ) POP3 web user interface

(Default - \Inetpub\Ftproot)

(Default - \Inetsrv\WWWroot)

( ) give a authorization to remote access to this computer.( ) risk-free security( ) mild security( ) number of connected devices  ( ) number of connected users

FTP service property (Only when FTP service is selected)

FTP site directoryWWW service property (Only when WWW service is selected)

License mode

WWW server directoryTerminal server property (Only when terminal server is selected)

Remote DesktopPlease select the default accesspermission for compatible application.

POP3 root component

(continued)

Terminal ServicesTerminal Services licensingRemote install Services

Certificate Service

Application server

Indexing Server Files

(Continuation of Software Components)Only when selecting component to install

Parameters

Application and utilities

29

E Design Sheet

Setting

( ) Services for Macintosh (SFM)( ) Print Service for Macintosh( ) Print Service for UNIX( ) WINS Server( ) Internet Authentication Service (IAS)( ) MS DNS Server( ) Simple TCP/IP Service( ) MS DHCP Serve

( ) Network Monitor tools( ) SNMP Service (Required to install SNMP-ServerView)

( ) Send

( ) Receive(only when specified)

( ) Physical ( ) Datalink and sub network( ) End-to-End ( ) Application ( ) Internet

( ) Install( ) Create a domain in a new forest( ) Additional domain controller of the existing domain( ) Create a new child domain under the existing domain tree( ) Create a new domain tree in the existing fores

( ) Permit

Domain NetBIOS name

User namePasswordDomain nameComplete DNS name ofthe new domain

Complete DNS name ofthe parent domainNew child domain nameDomain NetBIOS name

Create a new domain tree in the existing forest (only when selected)

Create a new child domain under the existing domain tree (only when selected)User namePasswordDomain

User namePasswordDomainComplete DNS name ofthe existing domain

Trap

Send authentication trap

Agent

AddressContact

Service

Receivable community nameReceive SNMP packet from all hostsHost name

Active Directory details setting (only when DNS is selected)Install Active Directory

Active Directory type

Database folder

Services

Other network File and PrintServices

Trap destinationSecurity

SNMP details (Only when SNMP is selected)

Community name

Parameters

Complete DNS name ofthe new domainDomain NetBIOS name

Additional domain controller of the existing domain (only when selected)

Log folderSYSVOL folder locationCompatibility withWindows 2000 or earlier

Create a domain in a new forest (only when selected)

Networking Services

Management and Monitoring Tools

30

PRIMERGY RX100 S5 Configuration Sheets

Setting

( ) Windows Server 2003 service pack1( ) ServerView(Apache version)/RAID Management Tool( ) ServerView(IIS version)/RAID Management Tool( ) DSNAP( ) Broadcom Advanced Control Suite(BACS)

(only when selecting additional software)

( ) Install selected application from Local CD( ) Install selected application from Remote Server

When installing from remote server ( ) Install ( ) Do not install

Remote Source PathRemote UsernameRemote Password

Parameters

Installable applications

Userspecific Command

Userspecific Command

E.3 Application Wizard

31

F Accident Sheet

□ PRIMERGY RX100 S5 (PG   )

 OS

 DATE/TIME

 Phase of accident

Yes / NoAttached paper

Name (Product ID)

 Environment

LAN/WAN config.

F Accident Sheet

What did you do?, what message? etc.

32

 • The contents of this manual may be revised without prior notice. • Fujitsu assumes no liability for damages to third party copyrights or other rights arising from the use of any information in this manual. • No part of this manual may be reproduced in any form without the prior written permission of Fujitsu.

PRIMERGY RX100 S5

Configuration SheetsCA92276-8060-01

Issued on  May, 2008Issued by  FUJITSU LIMITED