About the Product - smstv.com · The PBN MIB is complementary to the Society of Cable...

6
OCMR Optical Communications Mainframe with Redundant power supplies Copyright 2010 Pacific Broadband Networks (PBN). All rights reserved. Reproduction without consent is prohibited. 1/6 In the interest of continuous product development, specifications may change without notice. Pbn.Ocmr - Datasheet V4e - Released 12 Jul 10 About the Product The OCMR with redundant power supply capability is the second generation Optical Communications Mainframe Chassis which forms the backbone of the Light Link Series 3 product range. The OCMR chassis is fully backward compatible with PBN’s complete range of optical, RF, and data modules to suit CATV, Ethernet, FTTC, FTTH, HFC and telecommunication applications. The new design employs the same form factor as its predecessor, the OCMC, still 5 RU high, 19” rack mountable, but now with 10 slots for high density applications and full power redundancy. Comprehensive control and monitoring of the OCM is included in the chassis itself, with a 4 line LCD and keypad to navigate through any of the modules’ various monitoring and control features. As a crucial element in any small or large city optical network, the OCMR is designed with fully modular and hot-swappable active parts which allow for continual system operation, providing uninterrupted services to the end subscriber. The OCMR can be optioned with an integrated SNMP agent and Ethernet port. This makes it possible to monitor and control an OCMR chassis through an IP network with PBN’s NMS3-NetCraft software or an SNMP manager.

Transcript of About the Product - smstv.com · The PBN MIB is complementary to the Society of Cable...

Page 1: About the Product - smstv.com · The PBN MIB is complementary to the Society of Cable Telecommunications Engineers (SCTE) published HMS standard MIB's. The OCMR is fully compatible

OCMR Optical Communications Mainframe with Redundant power supplies

Copyright 2010 Pacific Broadband Networks (PBN). All rights reserved. Reproduction without consent is prohibited. 1/6

In the interest of continuous product development, specifications may change without notice. Pbn.Ocmr - Datasheet V4e - Released 12 Jul 10

About the Product

The OCMR with redundant power supply capability is the second generation Optical Communications

Mainframe Chassis which forms the backbone of the Light Link Series 3 product range.

The OCMR chassis is fully backward compatible with PBN’s complete range of optical, RF, and data

modules to suit CATV, Ethernet, FTTC, FTTH, HFC and telecommunication applications.

The new design employs the same form factor as its predecessor, the OCMC, still 5 RU high, 19” rack

mountable, but now with 10 slots for high density applications and full power redundancy.

Comprehensive control and monitoring of the OCM is included in the chassis itself, with a 4 line LCD and

keypad to navigate through any of the modules’ various monitoring and control features.

As a crucial element in any small or large city optical network, the OCMR is designed with fully modular

and hot-swappable active parts which allow for continual system operation, providing uninterrupted

services to the end subscriber.

The OCMR can be optioned with an integrated SNMP agent and Ethernet port. This makes it possible to

monitor and control an OCMR chassis through an IP network with PBN’s NMS3-NetCraft software or an

SNMP manager.

Page 2: About the Product - smstv.com · The PBN MIB is complementary to the Society of Cable Telecommunications Engineers (SCTE) published HMS standard MIB's. The OCMR is fully compatible

OCMR Optical Communications Mainframe with Redundant power supplies

Copyright 2010 Pacific Broadband Networks (PBN). All rights reserved. Reproduction without consent is prohibited. 2/6

In the interest of continuous product development, specifications may change without notice. Pbn.Ocmr - Datasheet V4e - Released 12 Jul 10

Features

• 5 RU high, 19" wide, 10 slot chassis for PBN designed plug in modules.

• Can be equipped with dual, hot-swappable power supplies for redundant power applications.

• Large LCD panel for easy setup of modules and system monitoring.

• IEC297 compatible 19" rack.

• Space below modules for optical fibre patch cords and RF cable access.

• Mountable at ½ RU intervals allowing maximum use of rack space in communications cabinets.

• Horizontal, fan forced airflow permits the mounting of multiple OCMR without the need for rack space clearance between chassis.

• Local monitoring of system and modules via USB port.

• Remote monitoring via optional integrated SNMP agent and web server (HTTP) through 10Base-T Ethernet port for system wide, NMS3 network management.

• Hot-swappable front panel display and micro-controller assembly.

Remote monitoring and control features with the SNMP option

During normal operation the OCM user interface runs in status monitoring mode where it continuously

checks the entire OCMR chassis for urgent alarm conditions. If any of the plug-in modules report an urgent

failure, the LCD display will flash and the alarm condition is made available via the software for remote

monitoring computers. The OCMR also monitors various other module parameters for non-urgent alarm

conditions.

The OCMR employs an optional NMS3 network element manager which acts as a Simple Network

Management Protocol (SNMP) agent and a web server for monitoring via a web browser. The SNMP

agent and web server are available through a rear mounted, RJ45 (10Base-T) Ethernet port.

The SNMP option is supplied with a PBN Management Information Base (MIB) as well as PBN’s NMS3-

NetCraft software for Windows XP workstations. The PBN MIB is complementary to the Society of Cable

Telecommunications Engineers (SCTE) published HMS standard MIB's. The OCMR is fully compatible

with PBN NMS3-Enterprise II and NMS3-EPSM, with BarcoNet ROSA, with HP Open View, with CA

Unicenter, with Castle Rock, with NuDesign and with many other standards based SNMP monitoring

packages.

Please refer to our datasheets for NMS3-NetCraft, Enterprise II and NMS3-EPSM for more details on the

comprehensive network management features, the operational supports systems, the provisioning systems

and the billing systems.

Page 3: About the Product - smstv.com · The PBN MIB is complementary to the Society of Cable Telecommunications Engineers (SCTE) published HMS standard MIB's. The OCMR is fully compatible

OCMR Optical Communications Mainframe with Redundant power supplies

Copyright 2010 Pacific Broadband Networks (PBN). All rights reserved. Reproduction without consent is prohibited. 3/6

In the interest of continuous product development, specifications may change without notice. Pbn.Ocmr - Datasheet V4e - Released 12 Jul 10

NMS3 Network Management System Components

SNMP

NMS3 - Enterprise II

NMS3 - EPSM

Light Link Series 3

NMS3 - Netcraft

Light Link Series 2

Specifications

OCMR Chasis

Module slots 10 x OCM plug and play module capable

Alarms Directly to front panel LCD, remotely to, NO and NC alarm relay contact

Monitoring and control Integrated 4-line LCD display and keypad, USB port for local monitoring via laptop, SNMP network option with Ethernet port for remote monitoring and control via NMS3-NetCraft and NMS3-Enterprise-II systems.

Ethernet port 10Base-T, RJ45 socket (only with SNMP option)

IP address setting Automatically via DHCP or use static address through front panel keypad and LCD. (only with SNMP option)

NMS3-NetCraft-CD Configuration software on CD. (Supplied as a free inclusion to OCMR with SNMP option)

Page 4: About the Product - smstv.com · The PBN MIB is complementary to the Society of Cable Telecommunications Engineers (SCTE) published HMS standard MIB's. The OCMR is fully compatible

OCMR Optical Communications Mainframe with Redundant power supplies

Copyright 2010 Pacific Broadband Networks (PBN). All rights reserved. Reproduction without consent is prohibited. 4/6

In the interest of continuous product development, specifications may change without notice. Pbn.Ocmr - Datasheet V4e - Released 12 Jul 10

OCMPS Electrical Performance

Power supply modules Up to 2 hot swappable modules in the top tray of OCMR. One power supply can power a fully loaded chassis. 2 power supplies provide redundancy in case of single power supply failure.

Power input

OCMPS-230 OCMPS-HP-230 OCMPS-48

90 Vac to 264 Vac, 50/60 Hz 90 Vac to 264 Vac, 50/60 Hz -45 Vdc to -62 Vdc

Inrush current

OCMPS-230 OCMPS-48

2.5 A max 10 A max

Cooling In-built, thermistor controlled cooling fans. Two fans per power supply module.

General

Power rails - OCMPS 26.0 V, 4.0 A max, 14.5 V, 3.0 A max, -14.5 V, 1.0 A max

7.5 V, 7.0 A max

OCMPS-HP 26.5 V, 9.5 A max, 14.5 V, 9.0 A max, -14.5 V, 1.0 A max

7.5 V, 10 A max

Operating temperature 0 °C to 45 °C

Cooling Via cooling fans in OCMPS-* and OCMFAN modules

Maximum heat generation 870 BTU/h for a fully loaded chassis

Dimensions (HxWxD)

OCMR 225 x 485 x 440 mm

OCMPS-[*] / OCMFAN 50 x 210 x 350 mm

Ship size (HxWxD)

OCMR 400 x 600 x 600 mm

OCMPS-[*] / OCMFAN 70 x 280 x 570 mm

Weight

OCMR 6.5 kg

OCMPS-230 2.2 kg

OCMPS-48

OCMPS-HP-230

2.0 kg

2.0 kg

OCMFAN 1.0 kg

Ship weight

OCMR 13 kg

OCMPS-230 3.2 kg

OCMPS-48

OCMPS-HP-230

2.6 kg

2.6 kg

OCMFAN 1.6 kg

Page 5: About the Product - smstv.com · The PBN MIB is complementary to the Society of Cable Telecommunications Engineers (SCTE) published HMS standard MIB's. The OCMR is fully compatible

OCMR Optical Communications Mainframe with Redundant power supplies

Copyright 2010 Pacific Broadband Networks (PBN). All rights reserved. Reproduction without consent is prohibited. 5/6

In the interest of continuous product development, specifications may change without notice. Pbn.Ocmr - Datasheet V4e - Released 12 Jul 10

Order Details

OCMR-0 Chassis, empty.

OCMR-SNMP Chassis with SNMP module.

OCMR-SNMP-2B Chassis with SNMP module, with 2 x 48 V battery power supply modules.

OCMR-SNMP-ARC Chassis with SNMP module, with Alarm Relay Connection (ARC) providing relay output triggered by urgent alarms. No power supplies.

OCMR-SNMP-AU Chassis with SNMP module, with 2 x mains power supply modules, with 2 x mains cables for Australia GPO.

OCMR-SNMP-CN Chassis with SNMP module, with 2 x mains power supply modules, with 2 x mains cables for mainland China GPO.

OCMR-SNMP-EU Chassis with SNMP module, with 2 x mains power supply modules, with 2 x mains cables for continental Europe GPO.

OCMR-SNMP-HP Chassis with SNMP module, with 2 x 470 W mains power supply modules, with 2 x mains cables for each AU/CN/EU/UK/US.

OCMR-SNMP-UK Chassis with SNMP module, with 2 x mains power supply modules, with 2 x mains cables for United Kingdom GPO.

OCMR-SNMP-US Chassis with SNMP module, with 2 x mains power supply modules, with 2 x mains cables for USA GPO.

Power and cooling modules for OCMR chassis

OCMPS-230 Power supply module with fans for 90~264 Vac 50/60 Hz. 300 W

OCMPS-48 Power supply module with fans for -48 Vdc. 300 W

OCMPS-HP-230 Power supply module with fans for 90~264 Vac 50/60 Hz. 472 W Required for QOLTM deployments

OCMFAN Fan module for OCMR **

** Note: If more than 5 modules are loaded in a chassis, then for the purpose of adequate cooling either a second OCMPS-[X] power

supply module or an OCMFAN module needs to be installed. The fan module is powered from the chassis rails and does not

need a power cord.