OCMR Optical Communications Mainframe with Redundant power supplies
Copyright 2010 Pacific Broadband Networks (PBN). All rights reserved. Reproduction without consent is prohibited. 1/6
In the interest of continuous product development, specifications may change without notice. Pbn.Ocmr - Datasheet V4e - Released 12 Jul 10
About the Product
The OCMR with redundant power supply capability is the second generation Optical Communications
Mainframe Chassis which forms the backbone of the Light Link Series 3 product range.
The OCMR chassis is fully backward compatible with PBN’s complete range of optical, RF, and data
modules to suit CATV, Ethernet, FTTC, FTTH, HFC and telecommunication applications.
The new design employs the same form factor as its predecessor, the OCMC, still 5 RU high, 19” rack
mountable, but now with 10 slots for high density applications and full power redundancy.
Comprehensive control and monitoring of the OCM is included in the chassis itself, with a 4 line LCD and
keypad to navigate through any of the modules’ various monitoring and control features.
As a crucial element in any small or large city optical network, the OCMR is designed with fully modular
and hot-swappable active parts which allow for continual system operation, providing uninterrupted
services to the end subscriber.
The OCMR can be optioned with an integrated SNMP agent and Ethernet port. This makes it possible to
monitor and control an OCMR chassis through an IP network with PBN’s NMS3-NetCraft software or an
SNMP manager.
OCMR Optical Communications Mainframe with Redundant power supplies
Copyright 2010 Pacific Broadband Networks (PBN). All rights reserved. Reproduction without consent is prohibited. 2/6
In the interest of continuous product development, specifications may change without notice. Pbn.Ocmr - Datasheet V4e - Released 12 Jul 10
Features
• 5 RU high, 19" wide, 10 slot chassis for PBN designed plug in modules.
• Can be equipped with dual, hot-swappable power supplies for redundant power applications.
• Large LCD panel for easy setup of modules and system monitoring.
• IEC297 compatible 19" rack.
• Space below modules for optical fibre patch cords and RF cable access.
• Mountable at ½ RU intervals allowing maximum use of rack space in communications cabinets.
• Horizontal, fan forced airflow permits the mounting of multiple OCMR without the need for rack space clearance between chassis.
• Local monitoring of system and modules via USB port.
• Remote monitoring via optional integrated SNMP agent and web server (HTTP) through 10Base-T Ethernet port for system wide, NMS3 network management.
• Hot-swappable front panel display and micro-controller assembly.
Remote monitoring and control features with the SNMP option
During normal operation the OCM user interface runs in status monitoring mode where it continuously
checks the entire OCMR chassis for urgent alarm conditions. If any of the plug-in modules report an urgent
failure, the LCD display will flash and the alarm condition is made available via the software for remote
monitoring computers. The OCMR also monitors various other module parameters for non-urgent alarm
conditions.
The OCMR employs an optional NMS3 network element manager which acts as a Simple Network
Management Protocol (SNMP) agent and a web server for monitoring via a web browser. The SNMP
agent and web server are available through a rear mounted, RJ45 (10Base-T) Ethernet port.
The SNMP option is supplied with a PBN Management Information Base (MIB) as well as PBN’s NMS3-
NetCraft software for Windows XP workstations. The PBN MIB is complementary to the Society of Cable
Telecommunications Engineers (SCTE) published HMS standard MIB's. The OCMR is fully compatible
with PBN NMS3-Enterprise II and NMS3-EPSM, with BarcoNet ROSA, with HP Open View, with CA
Unicenter, with Castle Rock, with NuDesign and with many other standards based SNMP monitoring
packages.
Please refer to our datasheets for NMS3-NetCraft, Enterprise II and NMS3-EPSM for more details on the
comprehensive network management features, the operational supports systems, the provisioning systems
and the billing systems.
OCMR Optical Communications Mainframe with Redundant power supplies
Copyright 2010 Pacific Broadband Networks (PBN). All rights reserved. Reproduction without consent is prohibited. 3/6
In the interest of continuous product development, specifications may change without notice. Pbn.Ocmr - Datasheet V4e - Released 12 Jul 10
NMS3 Network Management System Components
SNMP
NMS3 - Enterprise II
NMS3 - EPSM
Light Link Series 3
NMS3 - Netcraft
Light Link Series 2
Specifications
OCMR Chasis
Module slots 10 x OCM plug and play module capable
Alarms Directly to front panel LCD, remotely to, NO and NC alarm relay contact
Monitoring and control Integrated 4-line LCD display and keypad, USB port for local monitoring via laptop, SNMP network option with Ethernet port for remote monitoring and control via NMS3-NetCraft and NMS3-Enterprise-II systems.
Ethernet port 10Base-T, RJ45 socket (only with SNMP option)
IP address setting Automatically via DHCP or use static address through front panel keypad and LCD. (only with SNMP option)
NMS3-NetCraft-CD Configuration software on CD. (Supplied as a free inclusion to OCMR with SNMP option)
OCMR Optical Communications Mainframe with Redundant power supplies
Copyright 2010 Pacific Broadband Networks (PBN). All rights reserved. Reproduction without consent is prohibited. 4/6
In the interest of continuous product development, specifications may change without notice. Pbn.Ocmr - Datasheet V4e - Released 12 Jul 10
OCMPS Electrical Performance
Power supply modules Up to 2 hot swappable modules in the top tray of OCMR. One power supply can power a fully loaded chassis. 2 power supplies provide redundancy in case of single power supply failure.
Power input
OCMPS-230 OCMPS-HP-230 OCMPS-48
90 Vac to 264 Vac, 50/60 Hz 90 Vac to 264 Vac, 50/60 Hz -45 Vdc to -62 Vdc
Inrush current
OCMPS-230 OCMPS-48
2.5 A max 10 A max
Cooling In-built, thermistor controlled cooling fans. Two fans per power supply module.
General
Power rails - OCMPS 26.0 V, 4.0 A max, 14.5 V, 3.0 A max, -14.5 V, 1.0 A max
7.5 V, 7.0 A max
OCMPS-HP 26.5 V, 9.5 A max, 14.5 V, 9.0 A max, -14.5 V, 1.0 A max
7.5 V, 10 A max
Operating temperature 0 °C to 45 °C
Cooling Via cooling fans in OCMPS-* and OCMFAN modules
Maximum heat generation 870 BTU/h for a fully loaded chassis
Dimensions (HxWxD)
OCMR 225 x 485 x 440 mm
OCMPS-[*] / OCMFAN 50 x 210 x 350 mm
Ship size (HxWxD)
OCMR 400 x 600 x 600 mm
OCMPS-[*] / OCMFAN 70 x 280 x 570 mm
Weight
OCMR 6.5 kg
OCMPS-230 2.2 kg
OCMPS-48
OCMPS-HP-230
2.0 kg
2.0 kg
OCMFAN 1.0 kg
Ship weight
OCMR 13 kg
OCMPS-230 3.2 kg
OCMPS-48
OCMPS-HP-230
2.6 kg
2.6 kg
OCMFAN 1.6 kg
OCMR Optical Communications Mainframe with Redundant power supplies
Copyright 2010 Pacific Broadband Networks (PBN). All rights reserved. Reproduction without consent is prohibited. 5/6
In the interest of continuous product development, specifications may change without notice. Pbn.Ocmr - Datasheet V4e - Released 12 Jul 10
Order Details
OCMR-0 Chassis, empty.
OCMR-SNMP Chassis with SNMP module.
OCMR-SNMP-2B Chassis with SNMP module, with 2 x 48 V battery power supply modules.
OCMR-SNMP-ARC Chassis with SNMP module, with Alarm Relay Connection (ARC) providing relay output triggered by urgent alarms. No power supplies.
OCMR-SNMP-AU Chassis with SNMP module, with 2 x mains power supply modules, with 2 x mains cables for Australia GPO.
OCMR-SNMP-CN Chassis with SNMP module, with 2 x mains power supply modules, with 2 x mains cables for mainland China GPO.
OCMR-SNMP-EU Chassis with SNMP module, with 2 x mains power supply modules, with 2 x mains cables for continental Europe GPO.
OCMR-SNMP-HP Chassis with SNMP module, with 2 x 470 W mains power supply modules, with 2 x mains cables for each AU/CN/EU/UK/US.
OCMR-SNMP-UK Chassis with SNMP module, with 2 x mains power supply modules, with 2 x mains cables for United Kingdom GPO.
OCMR-SNMP-US Chassis with SNMP module, with 2 x mains power supply modules, with 2 x mains cables for USA GPO.
Power and cooling modules for OCMR chassis
OCMPS-230 Power supply module with fans for 90~264 Vac 50/60 Hz. 300 W
OCMPS-48 Power supply module with fans for -48 Vdc. 300 W
OCMPS-HP-230 Power supply module with fans for 90~264 Vac 50/60 Hz. 472 W Required for QOLTM deployments
OCMFAN Fan module for OCMR **
** Note: If more than 5 modules are loaded in a chassis, then for the purpose of adequate cooling either a second OCMPS-[X] power
supply module or an OCMFAN module needs to be installed. The fan module is powered from the chassis rails and does not
need a power cord.