8/18/2019 ABC PI 210 010 Y Strainer Data Sheet_Rev A_comment
http://slidepdf.com/reader/full/abc-pi-210-010-y-strainer-data-sheetrev-acomment 1/5
A 22-Mar-16 ARD/PEL FV/MMU SD
PREPARED CHECKED APPROVED
© This document is copyright.
No part may be reproduced or used without the written permission of Premier Oil
CLASS REVISION STATUS
1 A IDR
MINI OIL REFINERY 2 X 20,000 BPD PROJECT
Issued For IDR
PREMIER OIL NATUNA SEA B.V.
DESCRIPTION
FEED CONSULTAN
COMPANY
PT. ABC
Front-End Engineering Design
DATA SHEET FOR Y-STRAINER
ABC-PI-200-010
STATUS CODE : A= Issued For Comments, B= Issued For Approval, C= Issued For Bid,
X=Cancelled, INFO= For Information, ITB = Invitation To Bid
REV DATE
8/18/2019 ABC PI 210 010 Y Strainer Data Sheet_Rev A_comment
http://slidepdf.com/reader/full/abc-pi-210-010-y-strainer-data-sheetrev-acomment 2/5
REV. NO. PAGE NO.
A
Doc No : ABC-PI-200-010
Front-End Engineering Project Rev : A Class : 1
Date : 22-Mar-16
PT. ABC Doc. Title:
Data Sheet For Y-StrainerPage 2 of 5
RECORD OF REVISION
Description of Change
Issued For IDR
SECTION
ALL
MINI OIL REFINERY 2 X 20,000 BPD PROJECT
The revisions listed below have been incorporated in this copy of the document.
8/18/2019 ABC PI 210 010 Y Strainer Data Sheet_Rev A_comment
http://slidepdf.com/reader/full/abc-pi-210-010-y-strainer-data-sheetrev-acomment 3/5
Sheet 3 of 7
Description Page No
DESCRIPTION OF CHANGES 2CONTENTS 3
Y-STRAINER LIST 4Y-STRAINER DATA 5
Doc No : ABC-PI-200-010
Front-End Engineering Project Rev: : A Class: 1
Date : 22-Mar-16
MINI OIL REFINERY 2 X 20,000 BPD PROJECT
CONTENTS
PT. ABCDOC. No.
ABC-PI-210-010Data Sheet For Y-Strainer
8/18/2019 ABC PI 210 010 Y Strainer Data Sheet_Rev A_comment
http://slidepdf.com/reader/full/abc-pi-210-010-y-strainer-data-sheetrev-acomment 4/5
A
Rev
Design Operating Design Operating
1 SP-03-01 6" 1 3/4" N.P.T Produced Water 150# RF 7 bar 3-5 bar 650C AMB
2 SP-03-02 6" 1 3/4" N.P.T Produced Water 150# RF 7 bar 3-5 bar 650C AMB
3 SP-03-03 4" 1 3/4" N.P.T Caustic Soda 150# RF 11 bar 3-5 bar 650C 35
0C
4 SP-03-04 4" 1 3/4" N.P.T Caustic Soda 150# RF 11 bar 3-5 bar 650C 35
0C
5 SP-03-05 3" 1 3/4" N.P.T Caustic Soda 150# RF 11 bar 3-5 bar 650C 35
0C
6 SP-03-06 3" 1 3/4" N.P.T Caustic Soda 150# RF 11 bar 3-5 bar 650C 35
0C
7 SP-03-07 4" 1 3/4" N.P.T Fire Water 150# RF 12.5 bar 7.11 bar 650C AMB
8 SP-03-08 4" 1 3/4" N.P.T Fire Water 150# RF 11 bar 3-5 bar 650C AMB
Note : 1. Process Data will be available at detail engineering stage.
Issued For IDR
TBA
(Note 1)
TBA
(Note 1)
TBA
(Note 1)
TBA
(Note 1)
TBA
(Note 1)
ARD/P
Engineering Description PREPA
Table 1. Carbon Steel Y - Strainer List
PT ABC DATA SHEET FOR Y-STRAINER
CRUDE OIL REFINERY PILOT PROJECT
Front-End Engineering Design
NoANSI
RatingService
Flowrate
(Usgpm)
Density
(lb/ft3)
Max allw.
Press. Drop
(psig)
Viscosity
(cP)
TemperatureTAG No.
Line
Size
Qty
(ea)Mesh
Drain
Connection
Pressure
FF
8/18/2019 ABC PI 210 010 Y Strainer Data Sheet_Rev A_comment
http://slidepdf.com/reader/full/abc-pi-210-010-y-strainer-data-sheetrev-acomment 5/5
5 of 5
A
Rev
RF FLANGED END RATING 150# FF FLANGED END RATING 150#
DESIGN REQUIREMENTS
PIPING CLASSES : MA , UA
DESIGN STANDARD : ASME B 31.3 / ASME SECTION VIII, DIVISION 1
END CONNECTION : RF FLANGED ANSI B 16.5 for MA Piping Class
FF FLANGED ANSI B 16.5 for UA Piping Class
SIZE : SEE TABLE 1
DRAIN CONNECTION : THREADED PLUG FOR RATING 150# (NOTE 3, 4)
MESH SIZE : AS PER TABLE 1, SHALL BE IN ACCORDANCE WITH ASTM E 2016 OR EQUAL
MINIMUM OPEN AREA : 200%
MATERIAL REQUIREMENTS
BODY / COVER : ASTM A 105
SCREEN : SHALL BE IN ACCORDANCE WITH ASTM E 674 OR EQUAL (NOTE 5)GASKET : SPWD 316SS WINDING AND GRAPHITE FILLER
BOLTS : A193 Gr. B7 FLUORO CARBON COATED WITH AMERI-COTE OR EQUAL
NUTS : A194 Gr. 2H FLUORO CARBON COATED WITH AMERI-COTE OR EQUAL
INSPECTION AND TESTING REQUIREMENTS
VISUAL EXAMINATION : 100% AS PER MSS-SP-55
LIQUID PENETRANT EXAMINATION : AS REQUIRED (NOTE 6)
RADIOGRAPHIC EXAMINATION : NOT REQUIRED
HYDROSTATIC PRESSURE TESTING : YES (1.5 X DESIGN PRESSURE)
CERTIFICATION : BS EN 10204 TYPE 3.1
No
1 STRAINER TO BE SUPPLIED WITH A STAINLESS TAG NUMBER STAMPED AS PER TABLE SECURELY FIXED TO THE BODY WITH A NON CORROSIVE WIRE.
2 EXTERNAL PAINTING OF STRAINERS SHALL BE AS PER DOCUMENT : ABC-PI-200-004
3 DRAIN CONNECTION COMPLETE WITH PLUG FOR RATING 150#. DRAIN VALVE WILL BE PROVIDED BY PIPING
4 DRAIN CONNECTION SHALL BE AT LOW POINT ON THE BLIND FLANGE
5 SCREENS SHALL BE A MINIMUM OF 24 GAUGE (0.0239 INCH) PERFORATED TYPE 304 SS PLATE WITH 5/32 INCH (4 mm) DIAMETER STAGGERED HOLES AT 3/16 INCH (5 mm) CENTERS
AND 63 PERCENT OPEN AREA, LINED WITH 30 MESH (567 MICRON) AND 0.011 INCH (0.28 mm) DIAMETER WIRE TYPE 304 S S AND 45 PERCENT OPEN A REA
6 100% LIQUID PENETRANT TEST SHALL BE CONDUCTED FOR WELDED STRAINER 150#.
NOTES
Engineering Description PREPARED CHECKED APPROVED COMPANY
Issued For IDR ARD/PEL FV/MMU SD
ABC-PI-210-010
Sheet
CRUDE OIL REFINERY PILOT
PROJECT
Front-End Engineering Design
PT ABC DATA SHEET FOR Y-STRAINER
DOC. NO
Drain Connection(Note 3, 4)
Drain Connection(Note 3, 4)
Type 3.2
TBA