ABB_TRANSFER_ŞALTERİ
Transcript of ABB_TRANSFER_ŞALTERİ
Low Voltage Products
Change-over and transfer switchesRotary change-over and bypass cam switches
2
IECOT16E
OT25E
OT32E
OT45E
OT63E
OT125E
lth /A 25 32 40 63 80 125
le /AC-22A, < 415V 16 25 40 63 80 125
le /AC-23A, < 415V 16 20 23 45 75 90
16...1600 Amps Change-over switches
IECOT160E
OT200E
OT250E
OT160E_W
OT200E_W
OT250E_Wlth /A 160 200 250 160 200 250
le /AC-22A, < 415V 160 200 250 160 200 250
le /AC-23A, < 415V 160 200 250 160 200 250
IECOT315E
OT400E
OT630E
OT800E
OETL100K
OETL1250K
OETL1600Klth /A 315 400 630 800 1000 1250 1000
le /AC-22A, < 415V 315 400 630 800 1000 1250 1600
le /AC-23A, < 415V 315 400 630 800 800 800 800
Accessories
Optional handles Terminal shrouds
Extended shafts Connecting accessories
Auxiliary contacts Locking accessories
NOI
OO
FF
II
IS
0157
5A
NOIO
OFF
3
Change-over switchesTransfer switches Rotary change-over and bypass cam switches
Contents:
Open transition switches
Modular change-over switches OT 16...125
Technical data .......................................................................................................................... 7
Ordering information ........................................................................................................ 8 - 10
Modular change-over switches ............................................................................................. 8
Accessories .................................................................................................................... 8 - 10
Contact functions .................................................................................................................. 10
Dimension drawings ............................................................................................................. 11
Change-over switches OT 160...800, OETL 1000...1600 and OEM 200...1600
Technical data and operation functions ....................................................................... 13 - 15
Ordering information ...................................................................................................... 16 - 23
Change-over switches , manual operation ....................................................................16 - 17
Change-over switches , motor operation ......................................................................18 - 19
Accessories ...................................................................................................................20 - 23
Contact functions .................................................................................................................. 23
Dimension drawings ...................................................................................................... 24 - 29
Transfer switches OETL-NFC 200...1200, UL approved
Technical data ........................................................................................................................ 31
Ordering information ...................................................................................................... 32 - 33
Change-over switches .......................................................................................................... 32
Accessories ......................................................................................................................... 33
Contact functions ................................................................................................................. 34
Dimension drawings ...................................................................................................... 34 - 35
Closed transition switches
Transfer switches OESC 250...500
Technical data and contact functions .................................................................................. 37
Ordering information ............................................................................................................. 38
Transfer switches ................................................................................................................. 38
Accessories ......................................................................................................................... 38
Dimension drawings ............................................................................................................. 39
Rotary cam switches
Rotary change-over and bypass cam switches OM, ON and OL 40...200
Technical data ................................................................................................................. 41 - 42
Ordering information ...................................................................................................... 43 - 50
Change-over switches, OM, ON and OL ...................................................................... 43 - 45
Bypass switches, ON and OL .............................................................................................. 46
Accessories .................................................................................................................. 47 - 50
Dimension drawings ...................................................................................................... 51 - 53
3
1SKC000006C0201
4
Tested according to IEC 60947-6
Utilization categories: AC-31 for non-in-
ductive or slightly inductive load, AC-33
for motor loads or mixed loads including
motors.
is overloaded or when maintenance is
required.
Our solution for these installations
are change-over or transfer switches
with remote control by motor operator
or manual local operation. The range
consists of switches, mechanically
interlocked to each other, with electri-
cal characteristics that allow an onload
switching between the two supplies.
The isolation of the primary and sec-
ondary circuits is assured by the posi-
tive contact opening function and the
reliable position indication.
The switches can also be built by using
available mechanism kits and standard
switch-disconnectors.
To meet the demands from different
markets the change-over switches are
tested according to IEC and UL and
certifi ed by KEMA.
III
Secured power supply to diverse
applications
◆ Change-over switch ◆ Change-over cam switch
◆ Closed transition switch
Special switches forsecured power supply
A secured power supply to diverse ap-
plications, from computers to industrial
processes, is more and more important
as the optimizing of costs for lack of
production and maintenance is crucial
for a successful business.
The complex systems of distributing
power in emergency cases are often
controlled by logics, with mechanical
devices for making & breaking,
conducting and isolating power.
On the other hand, the loads may need to
be transferred from one supply to another.
This is the case when the use of energy
is restricted, when the supplying source
The tests are performed for frequent,
suffi x A, and infrequent, suffi x B, opera-
tions. The endurance requirements for a
change-over application between two
power circuits under load is normally met
only by a lifetime fulfi lling IEC 60947-6.
5
The closed transition transfer switch
is a “make before break” switch type
which guarantees a transfer of the sup-
ply without any interruption. The switch
is equipped with overlapping positions
I - II.
The change-over switch is equipped with
three stable positions and is independent
of external supply, in operations there is
no risk of an unexpected opening of the
switch due to loss of supply voltage and
no supply voltage is necessary to keep
the switch in the closed position.
◆ Local operation ◆ Change-over switches◆ Closed transition switches for
UPS applications
Example of electrical (I= 315 A) lifetime test:
Number of operating cycles
Suffi x Suffi x I Test
Operating
A B [A] cycle
IEC 60947-3 AC-23
1000 200 315 O-I-O
IEC 60947-6 AC-33
4000 1000 630 O-I-O-II-O
◆ Remote control
Two operation options
Manual operation: using a handle fi xed di-
rectly onto the switch, to the panel board
or to the door of the panel board. This
type of operation extends the operation
time between the two supplies.
Motorised operation: no human par-
ticipation is needed for the intervention,
and consequently the operation time
between the normal and the alternate
supply is short.
6
Modular change-over switches
The change-over switch carries out the
switching and the reliable isolation between
the primary network supply and the alter-
nate supply, thus ensuring the continuity of
performance.
The modular change-over switch range
OT16...125 offers a most compact solution.
The space requirements for a change-over
switch is the same as for the switch-discon-
nectors next to each other. Only in depth it
needs 11 mm in addition.
It is easy to install: mounting onto 35 mm
DIN-rail and it’s suitable for 45 mm cut-outs
for consumer units.
Open transition switches
Technical data
7
1SKC000006C0201
Switch size OT16_ OT25_ OT32_ OT45_ OT63_ OT125_
Rated insulation voltage and rated
operational voltage AC20/DC20 Pollution degree 3
V 750 750 750 750 750 750
Dielectric strength 50 Hz 1min. kV 6 6 6 6 6 6
Rated impulse withstand voltage kV 8 8 8 8 8 8
Rated thermal current and rated operational / ambient 40°C In open air A 25 32 40 63 80 125
current AC20/DC20 / ambient 40°C In enclosure A 25 32 40 63 80 125
/ ambient 60°C In enclosure A 20 25 32 50 63 100
..with minimum conductor cross section Cu mm2 4 6 10 16 25 50
Rated operational current, AC-21A up to 500 V A 16 25 40 63 80 125
690 V A 16 25 40 63 80 125
Rated operational current, AC-22A up to 500 V A 16 25 40 63 80 125
690 V A 16 25 40 63 80 125
Rated operational current, AC-23A up to 415 V A 16 20 23 45 75 90
440 V A 16 20 23 45 65 78
500 V A 16 20 23 45 58 70
690 V A 10 11 12 20 20 50
Rated operational power, AC-23A 1)
The kW-ratings are accurate for 3-phase 1500 230 V kW 3 4 5,5 11 22 22
R.P.M. standard asychronous motors 400 V kW 7.5 9 11 22 37 45
415 V kW 7.5 9 11 22 37 45
500 V kW 7.5 9 11 22 37 45
690 V kW 7.5 9 11 15 18.5 45
Rated breaking capacity in up to 415 V A 128 160 184 360 640 720
category AC-23 440 V A 128 160 184 360 448 624
500 V A 128 160 184 360 464 560
690 V A 80 88 96 160 160 400
Rated conditional short-circuit Ip (R.M.S.) 50 kA, 415 V kA 6.5 6.5 6.5 13 13 16.5
current Ip (R.M.S.) and Max. OFA_ fuse size gG/aM A/A 40/32 40/32 40/32 100/80 100/80 125/125
corresponding max. allowed Ip (R.M.S.) 100 kA, 500 V kA 17 17
cut-off current îc peak value. Max. OFA_ fuse size gG/aM A/A 100/80 100/80
The cut-off current îc refers to values
listed by fuse manufacturers
(single phase test acc. to IEC60269).
Rated short-time withstand current R.M.S. value Icw
690 V 0.15s kA
690 V 0.25s kA
690 V 1s kA 0.5 0.5 0.5 1 1.5 2.5
Rated short-time making capacity Peak value Icm
690 V kA 0.7 0.7 0.7 1.4 2.1 3.6
Mechanical endurance Divide by four for oper. cycles 2)
Oper. 20000 20000 20000 20000 20000 20000
Cable size Cu-wire size suitable for terminal clamps
mm2 0.75-10 0.75-10 0.75-10 1.5-35 1.5-35 10-70
AWG 18-8 18-8 18-8 14-4 14-4 8-00
Terminal tightening torque Counter torque required Nm 0.8 0.8 0.8 2 2 6
Operating torque Typical for 3-pole switch-disconnector
Nm 1 1 1 1.2 1.2 2
Weight without accessories 3-pole switch kg 0.25 0.25 0.25 0.64 0.64 0.90
4-pole switch kg 0.31 0.31 0.31 0.70 0.70 1.18
Data according to UL508 (Listed)
Current A 16 25 40 60 80
Horsepower, 3-phase 200 V HP 3 7.5 10 15 20
208 V HP 3 7.5 10 15 20
240 V HP 5 7.5 10 15 20
480 V HP 10 15 20 30 40
600 V HP 10 20 25 30 40
1) These values are given for guidance and may vary acc. to the motor manufacturer. 2) Operating cycle: O - I - O - II - O
Modular change-over switches
Data according to IEC 60947-3
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8
1SKC000006C0201
Ordering information
OA1G01
S00
261A
OA1G10
OA2G11
ON
OOFF
ON
OOFF
ION
O OFF
IION
S01
282A
OWC5D3
Modular change-over switches
OOFF
ION
OOFF
ION
S01
296A
S01
295A
OT125E3C
OT45...63E3C
I
OOFF
ON
I
OOFF
ON
S01
415A
OT16E3C
S00
262A
OTPS
OA7G10 OA8G01
S01
025A
Modular change-over switches, 3 pole, I-O-II -operation, open transitionInclude terminal clamps, IP20. Handle and shaft has to be ordered separately. OT 16...63 are UL Listed.
Rated current / Rated power Cable cross Type Order number Weight AC-21A...AC-22A AC-23A section [kg]Up to 415V 400V 400...415V I[A] S[kVA] I[A] / P[kW] [mm2]
16 11 16/7.5 0.75 … 10 OT16E3C 1SCA022605R8870 0.25 25 17 20/9 0.75 … 10 OT25E3C 1SCA022605R9920 0.2540 27 23/11 0.75 … 10 OT32E3C 1SCA022605R9410 0.2563 43 45/22 1.5 … 35 OT45E3C 1SCA022551R3880 0.6480 55 75/37 1.5 … 35 OT63E3C 1SCA022551R6210 0.64125 86 90/45 10 … 70 OT125E3C 1SCA022551R8680 0.90
Modular change-over switches, 4 pole, I-O-II -operation, open transitionInclude terminal clamps, IP20. Handle and shaft has to be ordered separately. OT 16...63 are UL Listed.
Rated current /Rated power Cable cross Type Order number Weight AC-21A...AC-22A AC-23A section [kg]Up to 415V 400V 400...415V I[A] S[kVA] I[A] / P[kW] [mm2]
16 11 16/7.5 0.75…10 OT16E4C 1SCA022551R4770 0.31
25 17 20/9 0.75…10 OT25E4C 1SCA022551R5580 0.31
40 27 23/11 0.75…10 OT32E4C 1SCA022551R3110 0.31
63 43 45/22 1.5…35 OT45E4C 1SCA022551R4340 0.70
80 55 75/37 1.5…35 OT63E4C 1SCA022551R6390 0.70
125 86 90/45 10…70 OT125E4C 1SCA022551R8760 1.18
AccessoriesChange-over kitsThe modular change-over switches can be built up by adding a compact snap-on kit on the top of two switch-disconnectors. The kits do not require any additional foot print area, only the height is increased 12 mm.
For switches For shafts Type Order number Weight
[kg]
OT16…32E OXS5_, OXP5_ OWC5D1 1SCA022551R9220 0.03OT45…80E OXS5_, OXP5_ OWC5D2 1SCA022574R8760 0.07OT100...125E OXS5_, OXP5_ OWC5D3 1SCA022574R8840 0.09
Auxiliary contacts
Snap-on mounting to the switch, IP 20, max. 2 blocks/ side.
Suitable for cable cross sections max. 2 x 2,5 mm2. See the contact functions, page 10.
For switches Contact Installation Type Order number Weight
functions side [kg]
OT16...125E_C 1NO Right OA1G10 1SCA022353R4970 0.03OT16...125E_C 1NC Right OA8G01 1SCA022744R2240 0.03OT16...125E_C 1NO Left OA7G10 1SCA022673R1140 0.03OT16...125E_C 1NC Left OA1G01 1SCA022353R4890 0.03OT45...125E3C 1NO+1NC Either OA2G11 1SCA022379R8010 0.03
4th polesSnap-on mounting to the left or right side of the switches, IP20. Simultaneous operation with power poles.
For switches Rated current / up to 415V Type Order number Weight
AC-21A /AC-22A AC-23A [kg]
I[A] I[A]
OT 16…32 40 23 OTPS32EP 1SCA022348R2480 0.03OT 45…63 80 75 OTPS63EP 1SCA022353R5350 0.06OT 125 125 90 OTPS125EP 1SCA022379R8010 0.14
9
1SKC000006C0201
Ordering informationAccessories
NOI
OO
FF
NOI
OO
FF
S01
368A
OHR2
S01
369A
OHR3
S00
535A
OHB9
S01
472A
S01
473A
OHB11
OHB12
0 OFF
I ON
S01
520A
ONII
OH_
OHB2_
S00
050B
S010
26A
OXS5x_
Handles and shaftsInternal handles, IP20
No shaft needed, direct mounting on the top of the switch.
For switches Colour Non Padlockable Type Order number Units/ Weight
padlockable in 0-position type [kg]
OT16…63 Black x OHB2/1 1SCA022660R4540 1 0.01 Black x OHR2 1SCA022648R3810 10 0.01 Red x OHR2/1 1SCA022660R4620 1 0.01 Red x OHR2 1SCA022645R2420 10 0.01
Black x OHB3/1 1SCA022659R7400 1 0.01 Black x OHB3 1SCA022648R4110 10 0.01 Red x OHR3/1 1SCA022660R4710 1 0.01 Red x OHR3 1SCA022648R4200 10 0.01
OT125 Black x OHB9/1 1SCA022660R5010 1 0.01 Black x OHB9 1SCA022648R3900 10 0.01 Red x OHR9/1 1SCA022660R4970 1 0.01 Red x OHR9 1SCA022648R4030 10 0.01
OT125 Black x OHB11/1 1SCA022692R5690 1 0.02 Black x OHB11 1SCA022680R8970 10 0.02
OT16…63 Black x OHB12/1 1SCA022692R0540 1 0.01 Black x OHB12 1SCA022687R9810 10 0.01 Red x OHR12/1 1SCA022692R0620 1 0.01 Red x OHR12 1SCA022692R0460 10 0.01
Selector type handlesSelector handle, black IP65, Nema type 1, 3R, 12, indication I-O-II. Padlockable in O -position with maximum three padlocks with bail diameter 5...8 mm (two lower holes) and 5...6.3 mm (the upper hole). Door interlock in I- and II-position and when padlocked in O-position.
For switches Colour Type Order number Weight
[kg]
OT16…125 Black OHB2AJE011 1SCA022698R3710 0.07OT16…125 Red-yellow OHY2AJE011 1SCA022698R3890 0.07
Shafts for selector type handlesFor switches Length Diameter Type Order number Weight
[mm] [mm] [kg]
OT 16…125 85 5 OXS5x85 1SCA022347R3570 0.03 105 5 OXS5x105 1SCA022347R3650 0.03
120 5 OXS5x120 1SCA022347R3730 0.04 130 5 OXS5x130 1SCA022353R4540 0.04
Pistol type handles, IP65The handles are equipped with door interlock function in both I- and II- position and when padlocked. Padlocking possibility in all positions with three padlocks, bail dia ∅ 5...10 mm. Indication I-O-II.
For switches Colour Type Order number Weight
[kg]
OT 16...125 Black OHB45J5E311 1SCA022615R1310 0.1 Red-yellow OHY45J5E311 1SCA022615R1490 0.1
Shafts for pistol type handlesFor switches Length Diameter Type Order number Weight
[mm] [mm] [kg]
OT 16…125 150 5 OXP5x150 1SCA022376R7300 0.05 170 5 OXP5x170 1SCA022376R7480 0.05 265 5 OXP5x265 1SCA022376R7560 0.08 400 5 OXP5x400 1SCA022376R7640 0.12
OXP5x_
10
1SKC000006C0201
Ordering informationS
0046
2A
S00
265A
OTS_T3
OTS_T1
S01
349A
S01
469A
S01
470A
OZXA 32
OZXT_
OZXA 33
Terminal shrouds
Snap-on mounting to the switches, IP20. The full shrouding of a 3-pole change-over switch is achieved with four 3-pole shrouds.
Suitable for Type Order number Weight
[kg]
For three pole switches
OT 16…32 OTS32T3 1SCA022353R6670 0.01OT 45…63 OTS63T3 1SCA022353R6750 0.01OT 125 OTS125T3 1SCA022379R9680 0.01
For fourth pole
OTPS 32EP OTS32T1 1SCA022353R6830 0.01OTPS 63EP OTS63T1 1SCA022353R6910 0.01OTPS 125EP OTS125T1 1SCA022379R9760 0.01
Parallel connection kitsFinger protected connection bars for parallel connection of the upper or lower terminals. The bars ac-cept additional cables, the maximum size is stated below.
For switches Cable size [mm2] Type Order number Weight
[kg]
OT16…32E3C 6 (fi ne stranded), 10 (stranded) OZXA33 1SCA022685R0310 0.02
OT16…32E4C 6 (fi ne stranded), 10 (stranded) OZXA32 1SCA022683R4110 0.03
OT45…63E3C 25 OZXA38 1SCA022785R2140 0.06
OT45…63E4C 25 OZXA39 1SCA022790R3820 0.09
OT100…125E3C 50 OZXA40 1SCA022790R3910 0.16
OT100…125E4C 50 OZXA41 1SCA022790R4040 0.24
Parallel connection terminalTerminal clamp for Al/Cu cables. The type includes 3 pcs.
OT125 2xAl/Cu 6…50 OZXT3 1SCA022639R0720 0.21
Interlocking device for locksCam attachment for Castell, Lowe & Fletcher or Ronis interlock. This accessory is mounted to the operating shaft of the switch and therefore only compatible with external handles. Lock, handle or shaft not included.
OT 16…125 OETLZW16 1SCA022093R2070 0.17
Accessories
, contact functions
S02078A
S0
20
77
AS
02
07
9A
S0
20
80
A
OZXA 38
OZXA 39
OZXA 40
OZXA 41
OETLZW16
S00059A
Contact functions for OT16...125
0 I I 0
S01
550A
0 II II 0
Load
I-Position/ Primary network
II-Position/ Secondary network
Maincontacts I
Maincontacts II
Auxiliarycontact NO
Auxiliarycontact NC
Auxiliarycontact NO
Auxiliarycontact NC
Auxiliarycontact NO
Auxiliarycontact NC
Auxiliarycontact NO
Auxiliarycontact NC
OA2G11
11
1SKC000006C0201
OT45...63
OT16...32
Modular change-over switchesDimension drawings
OT125
11 57
EN 50022
35
68
2,537
40
2735
L
5
40
12
S01306A
OH_45J5_
Ø66
45
4536
OH_ 45J5E311Shaft OXP5x L
150170265400
164...175184...195279...290414...425
OTS32T3
12
11 11
4060
ø4,522
37
11
OA1G10
OA1G01
102 5
OTPS32EP
13
54
OTS32T1
0 OFF
22
11 13
29,5
13
ION
IION
15
6,3
5,4
13
70 (3-pole)
96 (4-pole)
11 73,5
EN 50022
35
91,5
5,043,5
58
2
45
L
5
45,5
OH_45J5_
16
12
Ø66
45
4536
S01298A OH_ 45J5E311
Shaft OXP5x L150170265400
183...194203...214298...309433...444
15
17,5 17,5
5482,5
ø4,5
1143,5
37
11
OA1G10
OTS63T3OA1G01
105
OTPS63EP
OTS63T1
72,5
43,5
48
9
0 OFF
ION
IION
14
10
9 17,517,5
105 (3-pole)
140 (4-pole)
11 75 EN 50022
35100
6,544
56,5
L5
553,3
4516
12
Ø66
45
36
OH_45J5_
45
S0
12
99
A
OH _45J5E311
150170265400
192...206212...226307...321442...456
Shaft OXP5x L
22,5 22,5
6090
ø4,5
56
37
11
OA1G10
OTS125T3OA1G01
8 5
26,5
OTP_125EP
OTS125T1
26
41
10
11
OOFF
ION
5626
26,5
14
63
Ø4,5
0 OFF
ION
IION
16
12
12
140 (3-pole)
193 (4-pole)
12
Change-over switches
Open transition switches
In Automatic Transfer Switching Equipments the emergency
power is automatically transferred to one or more load circuits
from one supply to another by a logic system controlling the
OEM transfer switch.
The switches are mechanically interlocked to prevent simoulta-
neous connection to both normal and alternative supplies and
the operator independent quick make/quick break mechanism
ensures distinct opening and closing of the contacts.
The range is endurance tested as transfer switch according to
IEC 60947-6 categories AC-31 and AC-33, both for frequent and
infrequent use, and is independent of which logic system is used
for the automatic control.
0 I I 0 0 II II 0
Maincontacts I
Maincontacts II
I-Position/ Primary network
II-Position/ Secondary networkLoad
The connection of supplies to busbar
systems or the connection of the bus-
bars to earth, ensuring safe power off,
is secured in the change-over switch by
the inbuilt mechanical interlocking and
position change via OFF-position. They
prevent that parallel connection of two
supplies could not occur, even in case
of transient voltages. Transfer switch in ATSE
III
S02054A
OII
I
Technical data
13
1SKC000006C0201
Switch size OT160_ OT200_ OT250_ OT315_ OT400_ OT630_ OT800_
Rated insulation voltage and rated
operational voltage AC20/DC20 Pollution degree 3
V 1000 1000 1000 1000 1000 1000 1000
Dielectric strength 50 Hz 1min. kV 10 10 10 10 10 10 10
Rated impulse withstand voltage kV 12 12 12 12 12 12 12
Rated thermal current and rated operational / ambient 40°C In open air A 160 200 250 315 400 630 800
current AC20/DC20 / ambient 40°C In enclosure A 160 200 250 315 400 630 800
/ ambient 60°C In enclosure A
..with minimum conductor cross section Cu mm2 70 95 120 185 240 2x185 2x240
Rated operational current, AC-21A up to 500 V A 160 200 250 315 400 630 800
690 V A 160 200 250 315 400 630 800
Rated operational current, AC-22A up to 500 V A 160 200 250 315 400 630 800
690 V A 160 200 250 315 400 630 800
Rated operational current, AC-23A up to 415 V A 160 200 250 315 400 630 800
440 V A 160 200 250 315 400 630 800
500 V A 160 200 250 315 400 630 800
690 V A 160 200 250 315 400 630 800
Rated operational power, AC-23A 1)
The kW-ratings are accurate for 3-phase 1500 230 V kW 45 55 75 90 132 200 250
R.P.M. standard asychronous motors 400 V kW 90 110 132 160 200 355 400
415 V kW 90 110 132 160 200 355 400
500 V kW 110 132 160 200 250 400 560
690 V kW 160 160 250 315 400 630 800
Rated breaking capacity in up to 415 V 1280 1600 2000 2520 3200 5040 6400
category AC-23 440 V 1280 1600 2000 2520 3200 5040 6400
500 V A 1280 1600 2000 2520 3200 5040 6400
690 V A 1280 1600 2000 2520 3200 5040 6400
Rated conditional short-circuit Ip (R.M.S.) 50 kA, 415 V kA 40.5 40.5 40.5 50.5 50.5 60 60
current Ip (R.M.S.) and Max. OFA_ gG/aM A/A 355/315 355/315 355/315 500/500 500/500 800/1000 800/1000
corresponding max. allowed fuse size
cut-off current îc peak value I
p (R.M.S.) 100 kA, 500 V kA 40.5 40.5 40.5 61.5 61.5 75 75
Max. OFA_ fuse size
gG/aM A 315/315 315/315 315/315 500/450 500/450 800/800 800/800
The cut-off current îc refers to values
listed by fuse manufacturers Ip (R.M.S.) 80 kA, 690 V kA 40.5 40.5 40.5 59 59 70 70
(single phase test acc. to IEC60269). Max. OFA_ fuse size
gG/aM A 355/315 355/315 355/315 500/500 500/500 800/1000 800/1000
Rated short-time withstand current R.M.S. value Icw
690 V 0.15s kA 15 15 15 31 31 38 38
690 V 0.25s kA 15 15 15 24 24 36 36
690 V 1s kA 8 8 8 15 15 20 20
Rated short-time making capacity Peak value Icm
690 V kA 30 30 30 65 65 80 80
Mechanical endurance Divide by four for oper. cycles 2)
Oper. 16000 16000 16000 16000 16000 10000 10000
Terminal bolt size Metric thread diameter x length
mm M8x25 M8x25 M8x25 M10x30 M10x30 M12x40 M12x40
Terminal tightening torque Counter torque required
Nm 15-22 15-22 15-22 30-44 30-44 50-75 50-75
Operating torque Typical for 3-pole switch-disconnector
Nm 7 7 7 16 16 27 27
Weight without accessories 3-pole switch kg 2.5 2.5 2.5 4.7 4.7 12.8 12.8
4-pole switch kg 3.2 3.2 3.2 5.8 5.8 15.6 15.6
Data according to IEC 60947-3
Change-over switches
1) These values are given for guidance and may vary acc. to the motor manufacturer. 2) Operating cycle: O - I - O - II - O
14
1SKC000006C0201
Technical data
Change-over switches
1) The fuse in single phase test according to IEC 60269.
2) Maximum distance between busbar support and switch terminal 70 mm.
3) Operating cycle: O - I - O - II - O.
4) IEC947-3, utilization category B, infrequent operation.
OETL/OEM
200 250 315 400 630 800 1000 1250 1600Switch size
Rated insulation voltage and rated
operational voltage AC20/DC20 Pollution degree 3 V 1000 1000 1000 1000 1000 1000 1000 1000 1000
Dielectric strength 50 Hz 1min. kV 10 10 10 10 10 10 8 8 8
Rated impulse withstand voltage kV 12 12 12 12 12 12 8 8 8
Rated thermal current and rated operational current AC20/DC20
/ ambient 40°C In open air A 250 315 350 500 630 800 1000 1250 1600
/ ambient 40°C In enclosure A 200 270 315 500 630 720 1000 1250 1600
/ ambient 60°C In enclosure A 175 220 260 410 500 600 900 1000 1250
..with minimum conductor cross section Cu mm2 95 120 185 2x 2x 2x 2x 2x 2x
150 185 240 (60x5) (80x5) (100x5)
Rated operational current, AC-21A up to 690 V A 200 250 315 500 630 800 1000 1250 1600
1000 V A 200 250 315 400 630 630 1000 1000 1000
Rated operational current, AC-22A up to 500 V A 200 250 315 500 630 800 1000 1250 1600
690 V A 200 250 315 500 630 800
1000 V A 200 250 315 400 630 630
Rated operational current, AC-23A up to 415 V A 200 250 315 500 630 720 800 800 800
440 V A 200 250 315 500 590 670 800 800 800
500 V A 200 250 315 500 580 600 800 800 800
690 V A 200 250 315 350 350 350
1000 V A 125 125 125 125 4) 150 4) 150 4)
Rated operational power, The kW-ratings are 220-240 V kW 55 75 90 132 180 200 250 250 250
AC-23A accurate for 3-phase 400-415 V kW 110 132 160 200 315 355 400 400 400
1500 R.P.M. standard 440 V kW 110 132 160 315 355 355 400 400 400
asynchronous motors. 500 V kW 132 160 200 315 355 400 450 450 450
690 V kW 170 200 250 315 355 355
Cut-off current ic 1) I
r.m.s50 kA, ≤ 690 V kA 36 36 36 42 63 63 105 105 105
Cut-off current ic 1) I
r.m.s100 kA, 500 V kA 48 48 48 54 70 70
OFAA/ OFAM-fuse size A/ A 400 400 400 500 630/ 630/
800 800
Rated short-time r.m.s. -value Icw
690V, 1s kA 8 8 8 17 17 17 50 2) 50 2) 50 2)
Rated short circuit Peak value Icm
690V/500V kA 35 35 35 65 80 80 105 105 105
making capacity
Mechanical endurance Operating cycles 3) 8 000 8 000 8 000 5 000 5 000 5 000 3 000 3 000 3 000
Terminal bolt size Metric thread diameter x length mm 8x25 10x30 10x30 10x40 12x40 12x40 12x60 12x60 12x60
Terminal tightening torque Counter torque required Nm 30..44 30..44 30..44 30..44 50..75 50..75 50..75 50..75 50..75
Operating torque 3-pole switches Nm 13 13 13 22 22 22 25 25 25
Data according to IEC 60947-6
Rated operational current, AC-31B up to 415 V A 200 250 315 400 630 800 1000 1250 1600
Rated operational current, AC-33B up to 415 V A 200 250 315 400 630 800 800 800 800
Rated operational current, AC-31A up to 415 V A 200 250 315 400 630 800 1000 1250 1600
Rated operational current, AC-33A up to 415 V A 160 160 160 450 450 450 450 450
Data according to IEC 60947-3
Technical data
15
1SKC000006C0201
Technical data for motor operator OEM
Motor operator
Connection diagram for supply and control wires(max. 2,5 mm2)
Normal actions
Continuous command Operation cycle O � I � II � O Impulse command Operation cycle O � I � II � O
Minimum impulse duration 100 ms.
Incorrect commands
Continuous command
If two overlapping commands remain on the switch changes its
position between I and II continuously. This can be prevented by
mechanical or electrical interlocks in the control circuits.
Impulse command
If the switch is in O -, I- or II -position and two commands
are given at the same time, the switch changes its posi-
tion in occasional order.
Operation functions
F3
PE
L1
S01
538A
Main Contacts I
Main Contacts II
Command I
Command O
Command II
Main Contacts I
Main Contacts II
Command I
Command O
Command II
Note! The switch position remains stable if the main
voltage or the operation command disappears.
See page 40 for suitable control switches for the
operation circuit.
Note! The switch position remains stable if the main volt-
age or the operation command disappears.
Nominal voltageU
s [V]
Type
Operation time [s]when operating
0-I, 0-II, I-0 or II-0
Operation time [s]when operating
I-II or II-I
OFF-time [s]when operating
I-II or II-I
Max. continuous operating rate
[cycles / h]
Max. short-time (≤ 10 cycles)
operating rate[cycles / h]Min Max Min Max Min Max
24 OEM200…315 0.2 0.8 0.6 1,6 0.3 0.8 360 720
48 OEM200…315 0.1 0.6 0.4 1.2 0.2 0.6 360 720
230 OEM200…315 0.2 0.8 0.7 1.6 0.2 0.9 360 720
24 OEM400…800 0.2 0.7 0.5 1.4 0.2 0.7 240 480
48 OEM400…800 0.1 0.4 0.3 1.2 0.2 0.6 240 480
230 OEM400…800 0.3 1.1 0.8 2 0.4 1 240 480
24 OEM1000…1600 0.3 1.1 0.7 2 0.4 1 120 240
48 OEM1000…1600 0.3 1 0.6 1.9 0.3 1 120 240
230 OEM1000…1600 0.4 1.4 1 2.7 0.5 1.4 120 240
Rated insulation voltage (control circuit), Ui
250VOperating temperature -5... +40°CRated control voltage 0.85...1.1 x U
sRated control frequency (230 VAC) 45...66 Hz
Nominal voltage
[V]
Operationalcurrent [A]
Max. current [A]
230 VAC 1 4
48 VAC/VDC 5 18
24 VAC/VDC 10 36
1
2
3
4
5
6
14 13
14 13
14 13
0
I
II
16
1SKC000006C0201
Ordering informationChange-over switches
OT315...400E03CP
OT160...250E03WCP
Manual change-over switches, 3-pole, I-0-II -operation, open transition
Including a black plastic IP65 I - 0 - II pistol type handle, padlockable in the 0-position, door interlock in the I- and II-positions and when padlocked. Table below. Rated current / Rated power Type Order number WeightAC-21A...AC-22A AC-23A Up to 415V 400V 400...415V
I[A] S[kVA] I[A] / P[kW] [kg]
Mechanism at the end of the switch
160 110 160/90 OT160E03CP 1SCA022772R6510 3.3200 135 200/110 OT200E03CP 1SCA022771R7520 3.3250 170 250/132 OT250E03CP 1SCA022771R3450 3.3315 215 315/160 OT315E03CP 1SCA022772R6780 5.9400 275 400/200 OT400E03CP 1SCA022771R8500 5.9630 435 630/355 OT630E03CP 1SCA022785R6050 17.7800 550 800/400 OT800E03CP 1SCA022785R6300 17.7
Mechanism between the poles
160 110 160/90 OT160E12CP 1SCA022776R9080 3.3200 135 200/110 OT200E12CP 1SCA022776R8510 3.3250 170 250/132 OT250E12CP 1SCA022776R9320 3.3315 215 315/160 OT315E12CP 1SCA022776R9910 5.9400 275 400/200 OT400E12CP 1SCA022776R9590 5.9630 435 630/355 OT630E12CP 1SCA022785R8690 17.7800 550 800/400 OT800E12CP 1SCA022785R8850 17.7
Mechanism at the end of the switch, with extended phase distance
160 110 160/90 OT160E03WCP 1SCA022772R8210 3.6 200 135 200/110 OT200E03WCP 1SCA022772R8720 3.6 250 170 250/132 OT250E03WCP 1SCA022772R8300 3.6
Mechanism at the right end of the switch
1000 690 800/400 OETL1000K3C 1SCA022574R7100 381250 860 800/400 OETL1250K3C 1SCA022574R7360 381600 1100 800/400 OETL1600K3C 1SCA022574R7520 40
OT160...250E03CP
OETL1000...1600K3C
NOI
O OFF
S01
294A Shafts, handle and bolt kits included as standard
Suitable for Shaft Handle Bolt kitswitches
OT160...250 OXP6x161 OHB65J6E011 M8x25OT315...400 OXP12x166 OHB95J12E011 M10x30OT630...800 OXP12x185 OHB125J12E011 M12x40OETL1000...1600 OXP12x325 OHB175J12E011 M12x60
OT630...800E03CP
17
1SKC000006C0201
Ordering information
Manual change-over switches, 4-pole, I-0-II -operation, open transition
Including a black plastic IP65 I - 0 - II pistol type handle, padlockable in the 0-position, door interlock in the I- and II-positions and when padlocked. Table below.
Rated current / Rated power Type Order number WeightAC-21A...AC-22A AC-23A Up to 415V 400V 400...415V
I[A] S[kVA] I[A] / P[kW] [kg]
Mechanism at the end of the switch
160 110 160/90 OT160E04CP 1SCA022775R9440 4.1200 135 200/110 OT200E04CP 1SCA022771R7280 4.1250 170 250/132 OT250E04CP 1SCA022775R4640 4.1315 215 315/160 OT315E04CP 1SCA022775R7150 7.1400 275 400/200 OT400E04CP 1SCA022771R8680 7.1630 435 630/355 OT630E04CP 1SCA022785R6130 21800 550 800/400 OT800E04CP 1SCA022785R6210 21
Mechanism between the poles
160 110 160/90 OT160E13CP 1SCA022777R0170 4.1200 135 200/110 OT200E13CP 1SCA022777R0250 4.1250 170 250/132 OT250E13CP 1SCA022777R0330 4.1315 215 315/160 OT315E13CP 1SCA022777R0410 7.1400 275 400/200 OT400E13CP 1SCA022777R0500 7.1630 435 630/355 OT630E13CP 1SCA022785R9070 21800 550 800/400 OT800E13CP 1SCA022785R9230 21
Mechanism at the end of the switch, with extended phase distance
160 110 160/90 OT160E04WCP 1SCA022775R0220 4.4200 135 200/110 OT200E04WCP 1SCA022775R0650 4.4250 170 250/132 OT250E04WCP 1SCA022775R0810 4.4
Mechanism at the right end of the switch1000 690 800/400 OETL1000K4C 1SCA022574R7280 501250 860 800/400 OETL1250K4C 1SCA022574R7440 50
1600 1100 800/400 OETL1600K4C 1SCA022574R7610 52
OT160...250E04CP
OT160...250E04WCP
OT315...400E13CP
Shafts, handle and bolt kits included as standard
Suitable for Shaft Handle Bolt kitswitches
OT160...250 OXP6x161 OHB65J6E011 M8x25OT315...400 OXP12x166 OHB95J12E011 M10x30OT630...800 OXP12x185 OHB125J12E011 M12x40OETL1000...1600 OXP12x325 OHB175J12E011 M12x60
OETL1000...1600K4C
S0
14
11
A
NOI
O OFF
Change-over switches
OT630...800E04CP
18
1SKC000006C0201
Ordering information
OEM1000...1600K3C
OEM200-315K3C
OEM400-800K3C
Change-over switches, motor operation, 3-pole, I-0-II -operation, open transition
Including a metallic I - 0 - II pistol handle, for manual operation.
Rated current / Rated power Type Order number WeightAC-21A...AC-22A AC-23A Up to 415V 400V 400...415V
I[A] S[kVA] I[A] / P[kW] [kg]
Motor operation, operational voltage Un = 24V AC/DC
200 135 200/110 OEM200K3C24AC/DC 1SCA022607R4990 19250 170 250/ 132 OEM250K3C24AC/DC 1SCA022607R5020 19315 215 315/160 OEM315K3C24AC/DC 1SCA022607R5110 19500 345 500/200 OEM400K3C24AC/DC 1SCA022607R5290 29630 435 630/315 OEM630K3C24AC/DC 1SCA022607R5370 29800 550 720/355 OEM800K3C24AC/DC 1SCA022607R5450 291000 690 800/400 OEM1000K3C24AC/DC 1SCA022607R5530 461250 860 800/400 OEM1250K3C24AC/DC 1SCA022607R5610 46
1600 1100 800/400 OEM1600K3C24AC/DC 1SCA022607R5700 48
Motor operation, operational voltage Un = 48V AC/DC
200 135 200/110 OEM200K3C48AC/DC 1SCA022607R6690 19250 170 250/ 132 OEM250K3C48AC/DC 1SCA022607R6510 19315 215 315/160 OEM315K3C48AC/DC 1SCA022607R6420 19500 345 500/200 OEM400K3C48AC/DC 1SCA022607R6340 29630 435 630/315 OEM630K3C48AC/DC 1SCA022607R6260 29800 550 720/355 OEM800K3C48AC/DC 1SCA022607R6180 321000 690 800/400 OEM1000K3C48AC/DC 1SCA022607R6000 461250 860 800/400 OEM1250K3C48AC/DC 1SCA022607R5960 46
1600 1100 800/400 OEM1600K3C48AC/DC 1SCA022607R5880 48
Motor operation, operational voltage Un = 230V AC
200 135 200/110 OEM200K3C230AC 1SCA022608R6770 19250 170 250/132 OEM250K3C230AC 1SCA022608R6850 19315 215 315/160 OEM315K3C230AC 1SCA022608R6930 19500 345 500/200 OEM400K3C230AC 1SCA022608R7070 29630 435 630/315 OEM630K3C230AC 1SCA022607R7150 29800 550 720/355 OEM800K3C230AC 1SCA022607R7230 291000 690 800/400 OEM1000K3C230AC 1SCA022607R7310 461250 860 800/400 OEM1250K3C230AC 1SCA022607R7400 46
1600 1100 800/400 OEM1600K3C230AC 1SCA022607R7580 49
Change-over switches
YASDA_
Handle and bolt kits included as standard
Suitable for Handle Bolt kitswitches
OEM200 YASDA23/ 1 M8x25OEM250...315 YASDA23/ 1 M10x30OEM400...800 YASDA23/ 2 M12x40OEM1000...1600 YASDA23/ 3 M12x60
l
O
l
O
S01
316A
OII
I
OII
I
S013
15A
OII
I
S013
05A
19
1SKC000006C0201
Ordering information
Change-over switches, motor operation, 4-pole, I-0-II -operation, open transition
Including a metallic I - 0 - II pistol handle, for manual operation.
Rated current / Rated power Type Order number WeightAC-21A...AC-22A AC-23A Up to 415V 400V 400...415V
I[A] S[kVA] I[A] / P[kW] [kg]
Motor operation, operational voltage Un = 24V AC/DC
200 135 200/110 OEM200K4C24AC/DC 1SCA022607R8550 20250 175 250/ 132 OEM250K4C24AC/DC 1SCA022607R8470 20315 217 315/160 OEM315K4C24AC/DC 1SCA022607R8390 20500 345 500/200 OEM400K4C24AC/DC 1SCA022607R8210 30630 435 630/315 OEM630K4C24AC/DC 1SCA022607R8120 30800 550 720/355 OEM800K4C24AC/DC 1SCA022607R8040 321000 690 800/400 OEM1000K4C24AC/DC 1SCA022607R7910 581250 860 800/400 OEM1250K4C24AC/DC 1SCA022607R7820 58
1600 1100 800/400 OEM1600K4C24AC/DC 1SCA022607R7660 60
Motor operation, operational voltage Un = 48V AC/DC
200 135 200/110 OEM200K4C48AC/DC 1SCA022607R8630 20250 175 250/ 132 OEM250K4C48AC/DC 1SCA022607R8710 20315 217 315/160 OEM315K4C48AC/DC 1SCA022607R8800 20500 345 500/200 OEM400K4C48AC/DC 1SCA022607R8980 30630 435 630/315 OEM630K4C48AC/DC 1SCA022607R9010 30800 550 720/355 OEM800K4C48AC/DC 1SCA022607R9100 321000 690 800/400 OEM1000K4C48AC/DC 1SCA022607R9280 581250 860 800/400 OEM1250K4C48AC/DC 1SCA022607R9360 58
1600 1100 800/400 OEM1600K4C48AC/DC 1SCA022607R9440 60
Motor operation, operational voltage Un = 230V AC
200 135 200/110 OEM200K4C230AC 1SCA022608R0370 20250 170 250/132 OEM250K4C230AC 1SCA022608R0290 20315 215 315/160 OEM315K4C230AC 1SCA022608R0110 20500 345 500/200 OEM400K4C230AC 1SCA022608R0020 30630 435 630/315 OEM630K4C230AC 1SCA022607R9950 30800 550 720/355 OEM800K4C230AC 1SCA022607R9870 321000 690 800/400 OEM1000K4C230AC 1SCA022607R9790 581250 860 800/400 OEM1250K4C230AC 1SCA022607R9610 58
1600 1100 800/400 OEM1600K4C230AC 1SCA022607R9520 60
S015
16A
OII
I
S01
517A
l
O
OII
Il
O
OII
I
S01
412A
OEM1000...1600K4C
OEM200-315K4C
OEM400-800K4C
Change-over switches
YASDA_
Handle and bolt kits included as standard
Suitable for Handle Bolt kitswitches
OEM200 YASDA23/ 1 M8x25OEM250...315 YASDA23/ 1 M10x30OEM400...800 YASDA23/ 2 M12x40OEM1000...1600 YASDA23/ 3 M12x60
20
1SKC000006C0201
Ordering information
NO I
O
OFF
S00
865A
Accessories
OHB_
S000
50A
OXP6_
OXP12_
OTV_
S0
19
97A
Extended shaftsSuitable for Installation Type Order number Weight switches depth [mm] [kg]
Shaft diameter 6 mm OT160...250E_C 166…214 OXP6X90 1SCA022064R1180 0.03 209…254 OXP6X130 1SCA022057R0570 0.04 240…285 OXP6X161 1SCA022067R1760 0.05 289…334 OXP6X210 1SCA022295R6080 0.06 369…414 OXP6X290 1SCA022042R6370 0.08 439…484 OXP6X360 1SCA022042R6530 0.11
Shaft diameter 12 mmOT315...400E_C 209…266 OXP12X107 1SCA022029R9750 0.12 243…307 OXP12X148 1SCA022658R5570 0.17 261…325 OXP12X166 1SCA022325R7100 0.20 280…344 OXP12X185 1SCA022325R6710 0.22 345…409 OXP12X250 1SCA022325R6980 0.29 375…439 OXP12X280 1SCA022137R5140 0.33 420…484 OXP12X325 1SCA022042R5810 0.38 490…554 OXP12X395 1SCA022042R5990 0.46 560…624 OXP12X465 1SCA022042R6020 0.54
OT630…800E_C 287...355 OXP12X148 1SCA022658R5570 0.17 324...422 OXP12X185 1SCA022325R6710 0.22 389...487 OXP12X250 1SCA022137R5140 0.29 464...562 OXP12X325 1SCA022042R5810 0.38 534...632 OXP12X395 1SCA022042R5990 0.46 604...702 OXP12X465 1SCA022042R6020 0.54
OETL1000…1600 364...437 OXP12X185 1SCA022325R6710 0.22 429...502 OXP12X250 1SCA022325R6980 0.29 504...577 OXP12X325 1SCA022042R5810 0.38 574...647 OXP12X395 1SCA022042R5990 0.46 644...717 OXP12X465 1SCA022042R6020 0.54
Handles, door mounting Plastic I - 0 - II handle, IP65, door interlock in I- and II-position and when padlocked.
Suitable for Colour Shaft diam. Type Order number Weight switches [mm] [kg]
Padlockable with three padlocks in 0-position
OT160…250E_C black 6 OHB65J6E011 1SCA022383R2480 0.12
red/yellow 6 OHY65J6E011 1SCA022779R1840 0.12
OT315…400E_C black 12 OHB95J12E011 1SCA022621R0760 0.12
red/yellow 12 OHY95J12E011 1SCA022621R0920 0.12
OT630…800E_C black 12 OHB125J12E011 1SCA022589R3340 0.14
red/yellow 12 OHY125J12E011 1SCA022615R1650 0.14
OETL1000...1600 black 12 OHB175J12E011 1SCA022459R9700 0.17
red/yellow 12 OHY175J12E011 1SCA022461R1920 0.17
Padlockable with three padlocks in I- , 0- and II-position
OT160…250E_C black 6 OHB65J6E311 1SCA022662R4730 0.12
OT315…400E_C black 12 OHB95J12E311 1SCA022779R2140 0.12
OT630…800E_C black 12 OHB125J12E311 1SCA022615R1730 0.14
OETL1000…1600 black 12 OHB175J12E311 1SCA022615R1810 0.17
Handles, direct mounting Plastic I - 0 - II handle, padlockable with three padlocks in 0-position. Includes a shaft and a mechanism cover.
OT160…250E_C black shaft incl. OTV250ECK 1SCA022783R0090 0.08
OT315…400E_C black shaft incl. OTV400ECK 1SCA022783R0170 0.26
OT630…800E_C black shaft incl. OTV800ECK 1SCA022797R2470 0.30
OHY_
NOI
OO
FF
S00
469A
OHB_
21
1SKC000006C0201
Ordering information
OOFF
ION
21 13
4133
S00
536A
Accessories
OTS_L OTS_S
OZXB2K
S00215A
S00216A
OZXB3K
S0
02
17
A
S0
02
18
A
S00220A
S00219A
OZXB4K
S0
02
21
A
S00222A
OZXB5K
S00223A
S0
02
24
A
S00
261A
OA_G_
Auxiliary contact blocksMounting on the right side of the switch: Max. 4 auxiliary contact blocks/switch (totally 8 blocks). Simultaneous action with the main contacts, IP20.
Suitable Contact Type Order number Weight
for switches function [kg]
OT160...800 1NO OA1G10 1SCA022353R4970 0.03 1NC OA3G01 1SCA022456R7410 0.03
Mounting locations, see dimensional drawings. Contact functions, see the page 23.
OEM200…315 1NO+1NC OZXK12 1) 1SCA022144R7400 0.08 2NO+2NC OZXK13 1) 1SCA022144R7230 0.12 2NO+2NC OZXK29 2) 1SCA022615R1570 0.08OETL/OEM400...1600 1NO+1NC OZXK1 1) 2) 1SCA022131R8690 0.12 2NO+2NC OZXK2 1) 2) 1SCA022131R8850 0.12
OZXK_
Terminal shrouds
Suitable for Number Description Type Order number Weight switches of poles [kg]
Snap-on mounting, grey plastic
Transparent shrouds for OT160...800 available on request, please replace the letter "G" with "T". Suit-able for the upper switch. A kit includes three (four) shrouds which can be used on either side of the switch.
OT160…250 3 Long type OTS250G1L/3 1SCA022731R8150 0.09 3 Short type OTS250G1S/3 1SCA022731R8310 0.06
OT160…250 4 Long type OTS250G1L/4 1SCA022731R8230 0.12 4 Short type OTS250G1S/4 1SCA022731R8400 0.08
OT315…400 3 Long type OTS400G1L/3 1SCA022736R8840 0.15 3 Short type OTS400G1S/3 1SCA022736R9060 0.09
OT315…400 4 Long type OTS400G1L/4 1SCA022736R9490 0.20 4 Short type OTS400G1S/4 1SCA022736R9650 0.12
OT630…800 3 Long type OTS800G1L/3 1SCA022776R7890 0.32 3 Short type OTS800G1S/3 1SCA022776R8190 0.17
OT630…800 4 Long type OTS800G1L/4 1SCA022776R7970 0.42 4 Short type OTS800G1S/4 1SCA022776R8270 0.26
Snap-on mounting, transparent plastic
OEM200..315 3 OETLZXC11 1SCA022608R1510 0.20 4 OETLZXC12 1SCA022608R1690 0.25
OEM400 3 OETLZXC13 1SCA022608R1770 0.30 4 OETLZXC14 1SCA022608R1850 0.35
OEM630 3 OETLZXC15 1SCA022608R7710 0.30 4 OETLZXC16 1SCA022608R7890 0.35
OEM800 3 OETLZXC17 1SCA022658R9300 0.35 4 OETLZXC18 1SCA022658R9480 0.40
OETL/OEM1000-1250 3 OETLZXC19 1SCA022658R9560 0.45 4 OETLZXC20 1SCA022658R9640 0.55
OETL/OEM1600 3 OETLZXC21 1SCA022658R9720 0.45 4 OETLZXC22 1SCA022658R9810 0.55
Snap-on mounting to the terminal clamps, transparent plastic, IP 2X.
Suitable for Number Type Order number Weigh
terminal clamps of poles [kg]
OZXB2, 2L 3 OZXB2K 1SCA022264R0010 0.05OZXB3, 4 3 OZXB3K 1SCA022264R0440 0.20OZXB5, 6 3 OZXB4K 1SCA022199R2850 0.24OZXB7, 7L 3 OZXB5K 1SCA022283R8040 0.13
OETLZXC 11...22
S01
414A
1) Suitable for the upper switch 2) Suitable for the lower switch
22
1SKC000006C0201
Ordering information
OZXB 8, 9
Accessories
OZXB 1L
OZXB 2
OZXB 2L, 7L
OZXB 3
OZXB 4
S01806A
S00
177A
S00
179A
S00
182A
S00
186A
S00
188A
Terminal clamp setsSuitable Cable cross Suitable Type Order number Package Weightfor switches section shroud
[mm2] [pcs] [kg]
Terminal clamp sets for Al- and Cu-cables
OT 160...250 10...70 OTS250_L OZXB1L 1SCA022169R2030 3 0.15 10...70 OTS250_L OZXB1L/1 1SCA022194R0030 1 0.05 25...120 OZXB2K OZXB2 1SCA022119R7610 3 0.34 25...120 OZXB2K OZXB2/1 1SCA022194R0200 1 0.12 25...120 OZXB2K OZXB2L 1SCA022158R7750 3 0.43 25...120 OZXB2K OZXB2L/1 1SCA022194R0460 1 0.15 95...185 OTS250_L OZXB8 1SCA022744R1510 3 0.50 95...185 OTS250_L OZXB8/1 1SCA022744R1600 1 0.15 95...240 OTS250_L OZXB9 1SCA022750R3210 3 0.50 95...240 OTS250_L OZXB9/1 1SCA022750R3300 1 0.15
OT 315...400 25...120 OZXB2K OZXB2L 1SCA022158R7750 3 0.43 25...120 OZXB2K OZXB2L/1 1SCA022194R0460 1 0.15 95…185 OZXB3K OZXB3 1SCA022136R8100 3 1.28 95…185 OZXB3K OZXB3/1 1SCA022194R0620 1 0.43 2x(95…185) OZXB3K OZXB4 1SCA022137R4760 3 1.71 2x(95…185) OZXB3K OZXB4/1 1SCA022194R0890 1 0.57 120...240 OZXB5K OZXB7 1SCA022185R0040 3 1.00 120...240 OZXB5K OZXB7/1 1SCA022194R1430 1 0.34 120...240 OZXB5K OZXB7L 1SCA022185R7130 3 1.17 120...240 OZXB5K OZXB7L/1 1SCA022194R1600 1 0.40 95...185 OTS400_L OZXB8 1SCA022744R1510 3 0.50 95...185 OTS400_L OZXB8/1 1SCA022744R1600 1 0.15 95...240 OTS400_L OXZB9 1SCA022750R3210 3 0.50 95...240 OTS400_L OZXB9/1 1SCA022750R3300 1 0.15
OT630…800 120…300 OZXB4K OZXB5 1SCA022137R2470 3 2.28 120…300 OZXB4K OZXB5/1 1SCA022194R1010 1 0.76 2x(120…300) OZXB4K OZXB6 1SCA022137R4920 3 3.12 2x(120…300) OZXB4K OZXB6/1 1SCA022194R1270 1 1.04
S00
082A
S00
083A
OZXA 11
OZXA 12...14
Terminal clamp sets for Cu-cables
Suitable Cable cross Type Order number Package Weightfor switches section
[mm2] [pcs] [kg]
OEM400 70…120 OZXA11 1SCA022025R6940 6 0.54OEM400 2x(70...95) OZXA12 1SCA022008R7650 6 0.66OEM400 120…185 OZXA12 1SCA022008R7650 6 0.66OEM630…800 2x(95…185) OZXA14 1SCA022008R7810 6 1.18OEM630…800 185...240 OZXA14 1SCA022008R7810 6 1.18
Terminal clamp sets for Al- and Cu-cables
OEM400 25...120 Al/Cu OZXB2L 1SCA022158R7750 3 0.43 OZXB2L/1 1SCA022194R0460 1 0.14
OETL/OEM400...1600 70…185 Al/Cu OZXB3 1SCA022136R8100 3 1.28 OZXB3/1 1SCA022194R0620 1 0.43 2x(70…185) Al/Cu OZXB4 1SCA022137R4760 3 1.71 OZXB4/1 1SCA022194R0890 1 0.57
OETL/OEM400…1600 120…300 Al/Cu OZXB5 1SCA022137R2470 3 2.28 OZXB5/1 1SCA022194R1010 1 0.76
OETL/OEM400...1600 2x(120…300) Al/Cu OZXB6 1) 1SCA022137R4920 3 3.12 OZXB6/11) 1SCA022194R1270 1 1.04
OEM400...800 120...240 Al/Cu OZXB7L 1SCA022185R7130 3 1.17 OZXB7L/1 1SCA022194R1600 1 0.40
Terminal clamp sets for connection bar OETLZXC 23
OEM400…630 70…185 Al/Cu OZXB3 1SCA022136R8100 3 1.28
OZXB3/1 1SCA022194R0620 1 0.43
2x(70…185) Al/Cu OZXB4 1SCA022137R4760 3 1.71
OZX4/1 1SCA022194R0890 1 0.57
OEM630…800 120…300 Al/Cu OZXB5 1SCA022137R2470 3 2.28 OZXB5/1 1SCA022194R1010 1 0.76
2x(120…300) Al/Cu OZXB6 1SCA022137R4920 3 3.12 OZXB6/1 1SCA022194R1270 1 1.04
1) For OEM400...800 use connection bar OETLZXC 23.
23
1SKC000006C0201
Ordering information
Contact functions for OETL/OEM200...1600
0 I I 0
S01
499A
0 II II 0
Maincontacts I
Maincontacts II
Auxiliarycontact NO
Auxiliarycontact NC
Auxiliarycontact NO
Auxiliarycontact NC
I-Position/ Primary network
II-Position/ Secondary network
Load
Note! The NO auxiliary contact, on switch I, in OEM200...315 closes at the same time as the main contacts.
Bridging bars The bridging bars provide a connection link either on the incoming or outcoming side of the switch.
Suitable Number Type Order number Weight for switches of poles [kg]
OT160…250 3 OTZC13 1SCA022767R6910 0.60 4 OTZC14 1SCA022767R7040 0.80OT315…400 3 OTZC23 1SCA022767R7120 0.60 4 OTZC24 1SCA022767R7210 0.80OT630…800 3 OTZC33 1SCA022785R7020 1.00 4 OTZC34 1SCA022785R7110 1.30OEM200…315 3 OETLZXC1 1SCA022608R0450 0.60 4 OETLZXC2 1SCA022608R0530 0.80OEM400 3 OETLZXC3 1SCA022608R0610 0.60 4 OETLZXC4 1SCA022608R0700 0.80OEM630…800 3 OETLZXC5 1SCA022608R0880 1.30 4 OETLZXC6 1SCA022608R0960 1.80OETL/OEM1000…1250 3 OETLZXC7 1SCA022608R1000 5.40 4 OETLZXC8 1SCA022608R1180 7.20OETL/OEM1600 3 OETLZXC9 1SCA022608R1260 7.50 4 OETLZXC10 1SCA022608R1340 10.0
OTZC_
OETLZXC1...10
Connection bar
For connecting Al/Cu cables using terminal clamps OZXB6. Mounting to bridging bars OETLZXC_.
Bolt kit included.
OEM400...800 1 OETLZXC23 1SCA022659R7580 0.20
Locking accessories Cam attachment for adopting the switches to Castell, Lowe&Fletcher or Ronis interlock. The lock is not included. Mounting to OXP-shaft, works together with OH-door handle and a shaft.
Suitable for Type Order number Weight switches [kg]
OT160…250 OETLZW16 1SCA022093R2070 0.17OT315…400 OETLZW5 1SCA022052R3900 0.14
Direct mounting to the switch with OH_ handle
OETL200...1600K_C OETLZWC1 1SCA022608R1420 1.10
OETLZW_
S00059A
OETLZWC 1
Accessories
NOI
O OFF
S01
518A
S0
14
13
A
OETLZXC23
24
1SKC000006C0201
OT160E03/04CP... OT250E03/04CP
Change-over switches
Dimension drawings
OT160E12/13CP... OT250E12/13CP
A
A1
A2
B
35
116
155
170
35
116
190
205
9,032,5
25
A2
20
58,3
100
A1
130
60 A
B
25
122
130150
150
37
38,5 3
72
187
25
83
65
OT160...250E_C
E03 E04
A 35 35
A1 116 116
A2 156 191
B 171 206
14
M0
00
94
/ O
T1
60
...2
50
_C
K
A
OT160... 250_CK
25
1SKC000006C0201
Change-over switches
Dimension drawings
OT315E12/13CP... OT400E12/13CP
OT315E03/04CP and OT400E03/04CP
OT160E03/04WCP... OT250E03/04WCP
26
1SKC000006C0201
Change-over switches
Dimension drawings
OT315E03/04CK... 400E03/04CK
OT630E03/04CP... 800E03/04CP
OT630E12/13CP... 800E12/13CP
27
1SKC000006C0201
OT630E03/04CK... 800E03/04CK
Change-over switches
Dimension drawings
61215
315
40D
OZXK 1 or 2
( Upper and Lower Switch )
15
212
I
O 254
95
C 50 59
B
A
190
52,5
39,5
20
333
14
Ø9
OETL 1000K3C...OETL1600K4C
A B C D
OETL 1000K3C 390 278 80 12OETL 1000K4C 470 358 80 12OETL 1250K3C 390 278 80 12 OETL 1250K4C 470 358 80 12 OETL 1600K3C 410 298 90 16OETL 1600K4C 500 388 90 16
OETL 1000K3COETL 1250K3COETL 1600K3C
12
15
I
O 254
95
C 50 59
B
A
190
52,5
39,5
20
333
14 Ø9
OETL 1000K4COETL 1250K4COETL 1600K4C
9x179x17
Ø66
175
361717
373373
I I
247327247327267357
I
24 24
Shaft OXP 12x Mounting depth/L
185250325395465
364...437429...502504...577574...647644...717
L
297
195
OZXK 1 or 2
( Upper and Lower Switch )
S0
12
91
A
OETL1000...1600
28
1SKC000006C0201
Change-over switches
Dimension drawings
180
260
324
4
126
276
145,5
159
l O162
137
Ø7 9x7
110
D
F
32
C
A
Ø B
102
OZXK 12 or 13(upper switch)
130
85
288
118
28
I II0
I
OEM 200K3C 9 20 289 157 46 149OEM 200K4C 9 20 335 203 46 195OEM 250K3C 11 25 289 157 46 149OEM 250K4C 11 25 335 203 46 195OEM 315K3C 11 25 289 157 46 149OEM 315K4C 11 25 335 203 46 195
ØB F A C D I
OEM 200K3C...OEM 315K4C
22
237
155
OZXK 29(lower switch)
S0
13
19
A
OEM200...315
OEM400...800
OEM 400K3COEM 400K4COEM 630K3COEM 630K4COEM 800K3COEM 800K4C
OEM 400K3C...OEM 800K4C
134
216
315
45H
H
172
276
145,5
159
OC
E
Ø7
13x7
150
D
F
32
B
A
ØG
120
l
85
288
118
307163
0
I II
28
I
17
295
165
OZXK 1 or 2 (upper and lower switch)
S01416D
8
55
A B C D E F G H I
291337323385339
409
162208194257210
280
205205223223223
223
46466262
70
70
180180185185185
185
2525
4040
40
40
1111
13,513,513,5
13,5
44555
5
146192178240194
264
29
1SKC000006C0201
ø31 ø5
45°
53
IION
ION
0OFF
S0
20
64
A
Change-over switches
Dimension drawings
OEM1000...1600
215 40D
D
212
276
145,5
159
15
I
O
25495
C 5059
B
A
190
52,5
39,5
20
333
14 Ø9
9x17
419
85288
118
227
317
28
I II
0
237317237317257347
I
24
OZXK 1 or 2 ( upper and lower switch )
OEM 1000K3COEM 1000K4COEM 1250K3COEM 1250K4COEM 1600K3COEM 1600K4C
OEM 1000K3C...OEM 1600K4C
414494414494434524
278358278358298388
808080809090
121212121616
A B C D I
195
S0
13
20
A
Plastic handles
L
45Ø66
II ON
O O
FF
B
S00473A
36Handle Handle length Shaft
type (mm) (mm)
L B
OH_65J6E_ 65 6OH_80J6E_ 80 6
OH_95J12E_ 95 12OH_125J12E_ 125 12OH_145J12E_ 145 12OH_175J12E_ 175 12OH_275J12E_ 275 12
Door drilling for OH_ handles:
ø31 ø5
45 °
53
0OFF
I ON
II ON
S02111A
30
Transfer switches, UL approved
This range is covering manual change-over functions from
primary supply to back-up supply in equipment specially de-
signed for the UL market, but also used on the IEC market.
The OETL-NFC range is UL 1008 Recognized for resistive load
up to 1200 A and for total load up to 630 A.
The corresponding IEC rating is up to 1600 A for the
OETL-NFC range.
Maincontacts I
Maincontacts II
I-Position/ Primary network
II-Position/ Secondary networkLoad
The global solution
Open transition switches
Technical data
31
1SKC000006C0201
Transfer switches
1) The fuse in single-phase test according to IEC 60269.2) Maximum distance between busbar support and switch terminal 70 mm.
3) Operating cycle: O - I - O - II - O.4) IEC947-3, utilization category B, infrequent operation.
Data according to UL1008 (Recognized)
Switch size OETL-NFC 200 400 600 800 1200
Resistive load
Voltage V 600 600 600 600 600
Current A 200 400 600 800 1200
Total load
Voltage V 240 240 240 240
Current A 200 400 500 630
Data according to IEC 60947-3
Rated insulation voltage and rated
operational voltage AC20/DC20 Pollution degree 3 V 1000 1000 1000 1000 1000
Dielectric strength 50 Hz 1min. kV 10 10 10 8 8
Rated impulse withstand voltage kV 12 12 12 8 8
Rated thermal current and rated operational current AC20/DC20
/ ambient 40°C In open air A 315 630 800 1250 1600
/ ambient 40°C In enclosure A 270 630 720 1250 1600
/ ambient 60°C In enclosure A 220 500 600 1000 1250
..with minimum conductor cross section Cu mm2 120 2x185
2x240
2x(80x5)
2x(100x5)
Rated operational current, AC-21A up to 690 V A 250 630 800 1250 1600
1000 V A 250 630 630 1000 1000
Rated operational current, AC-22A up to 500 V A 250 630 800 1250 1600
690 V A 250 630 800
1000 V A 250 630 630
Rated operational current, AC-23A up to 415 V A 250 630 720 800 800
440 V A 250 590 670 800 800
500 V A 250 580 600 800 800
690 V A 250 350 350
1000 V A 125 150 4) 150 4)
Cut-off current ic 1) I
r.m.s50 kA ≤ 690 V kA 36 63 63 105 105
Cut-off current ic 1) I
r.m.s100 kA, 500 V kA 48 70 70
Rated short-time withstand current
r.m.s. -value Icw
690V, 1s kA 8 17 17 50 2) 50 2)
Rated short circuit making capacity
Peak value Icm
690V kA 35 80 80 105 105
Mechanical endurance, manual Operating cycles 3) 6 000 4 000 3 000 3 000 3 000
Terminal bolt size Metric thread diameter x length mm 10x30 12x40 12x40 12x60 12x60
Terminal tightening torque Counter torque required Nm 30..44 50..75 50..75 50..75 50..75
Operating torque 3-pole switches Nm 13 22 22 25 25
Data according to IEC 60947-6
Rated operational current AC-31B up to 415 V A 250 630 800 1250 1600
AC-33B up to 415 V A 250 630 800 800 800
AC-31A up to 415 V A 250 630 800 1250 1600
AC-33A up to 415 V A 160 450 450 450 450
32
1SKC000006C0201
Ordering informationTransfer switches
OETL-NFC800-1200
NOI
O OFF
S012
93A
l
O
l
O
NOI
O OFF
S01
292A
NOI
O OFF
S01
294A
OETL-NFC200
OETL-NFC400-600
Change-over switches, 3-pole, I-O-II -operation, open transition
The change-over switches include a black handle IP65; see the table below, Nema type 1, 3R, 12, a
shaft and a bolt set for the cable connection and a set of phase barriers (200...600).
Rated current [A] Type Order number WeightUL1008 IEC60947-3 IEC60947-6 [kg]600 V ≤ 415 V ≤ 415 V Resistive AC-22A AC-31A
200 250 250 OETL-NFC200-P 1SCA022596R0980 10400 630 630 OETL-NFC400-P 1SCA022596R1010 19600 800 800 OETL-NFC600-P 1SCA022596R1100 19800 1250 1250 OETL-NFC800-P 1SCA022596R1280 381200 1600 1600 OETL-NFC1200-P 1SCA022596R1360 40
Change-over switches, 4-pole, I-O-II -operation, open transition
The change-over switches include a black handle IP65, Nema type 1, 3R, 12, shaft and bolt set for the cable connection and a set of phase barriers (200...600).
Rated current [A] Type Order number Weight UL1008 IEC60947-3 IEC60947-6 [kg]600 V ≤ 415 V ≤ 415 V Resistive AC-22A AC-31A
200 250 250 OETL-NFC200-4P 1SCA022702R4080 12400 630 630 OETL-NFC400-4P 1SCA022702R4160 23600 800 800 OETL-NFC600-4P 1SCA022705R1990 23800 1250 1250 OETL-NFC800-4P 1SCA022705R2020 501200 1600 1600 OETL-NFC1200-4P 1SCA022705R2110 52
Shafts, handles and bolt kits included as standard
The handles are equipped with door interlock function in both I- and II-position and when padlocked. Padlocking possibility in O-position with 3 padlocks, bail dia Ø 5...10 mm. Indication I-O-II.
Suitable Shaft Handle Bolt kit for switches
OETL-NFC 200_ OXP12x325 OHB125J12E011 M10x30OETL-NFC 400...600_ OXP12x325 OHB145J12E011 M12x40OETL-NFC 800...1200_ OXP12x325 OHB175J12E011 M10x50
NOI
OO
FF
S00
469A
OHB_
33
1SKC000006C0201
Ordering informationAccessories
OZXK_
OETLZX17...22
OETLZWC 1
NO I
O
OFF
S00
865A
S00
047A
OOFF
ION
21 13
4133
S00
536A
S01
414A
OXP 12X_
OHY_
1) Suitable for the upper switch. 2) Suitable for the lower switch.
OETLZXC1...10
NOI
O OFF
S01
518A
S01
413A
OETLZXC23
NOI
OO
FF
S00
469A
External handles, IP 65, Nema type 1, 3R, 12, indication I - O- II The handles are equipped with door interlock function in both I- and II-position and when padlocked. Padlocking with 3 padlocks, bail dia Ø5...10 mm.
For switches Colour Type Order number Weight [kg]
Padlocking possibility in O-position
OETL-NFC 200 black OHB125J12E011 1SCA022589R3340 0.14OETL-NFC 400...600 black OHB145J12E011 1SCA022399R8530 0.15OETL-NFC 800...1200 black OHB175J12E011 1SCA022459R9700 0.17
OETL-NFC200 red/yellow OHY125J12E011 1SCA022615R1650 0.14OETL-NFC400…600 red/yellow OHY145J12E011 1SCA022460R7060 0.15OETL-NFC800…1200 red/yellow OHY175J12E011 1SCA022461R1920 0.17
Padlocking possibility in all positions
OETL-NFC200 black OHB125J12E311 1SCA022615R1730 0.14OETL-NFC400…600 black OHB145J12E311 1SCA022500R1390 0.15OETL-NFC800…1200 black OHB175J12E311 1SCA022615R1810 0.17
Extended shaftsFor switches Length [mm] Type Order number Weight [kg]
OETL-NFC200…1200 395 OXP12x395 1SCA022042R5990 0.45
OETL-NFC200…1200 465 OXP12x465 1SCA022042R6020 0.53
Auxiliary contactsMounting locations, see dimension drawings. Contact functions, see the next page.
For switches Contact functions Type Order number Weight [kg]
OETL-NFC200 1NO+1NC OZXK12 1) 1SCA022144R7400 0.08OETL-NFC200 2NO+2NC OZXK13 1) 1SCA022144R7230 0.12OETL-NFC200 2NO+2NC OZXK29 2) 1SCA022615R1570 0.08OETL-NFC400...1200 1NO+1NC OZXK1 1) 2) 1SCA022131R8690 0.12OETL-NFC400...1200 2NO+2NC OZXK2 1) 2) 1SCA022131R8850 0.12
Terminal shroudsFor switches Number of poles Type Order number Weight [kg]
OETL-NFC400 3 OETLZXC17 1SCA022658R9300 0.35OETL-NFC400 4 OETLZXC18 1SCA022658R9480 0.40OETL-NFC800...1200 3 OETLZXC21 1SCA022658R9720 0.45OETL-NFC800...1200 4 OETLZXC22 1SCA022658R9810 0.55
Bridging barsThe bridging bars provide a connection link either on the incoming or outgoing side of the switch.
For switches Number of poles Type Order number Weight [kg]
OETL-NFC200 3 OETLZXC1 1SCA022608R0450 0.6OETL-NFC200 4 OETLZXC2 1SCA022608R0530 0.8OETL-NFC400...600 3 OETLZXC5 1SCA022608R0880 1.3OETL-NFC400...600 4 OETLZXC6 1SCA022608R0960 1.8OETL-NFC800 3 OETLZXC7 1SCA022608R1000 5.4OETL-NFC800 4 OETLZXC8 1SCA022608R1180 7.2OETL-NFC1200 3 OETLZXC9 1SCA022608R1260 7.5OETL-NFC1200 4 OETLZXC10 1SCA022608R1340 10.0
Connection bar
For connecting cables using terminal clamp OZXB6. Mounting to bridgingbars OETLZXC_. Bolt kit included.
For switches Type Order number Weight [kg]
OETL-NFC 400...600 1 OETLZXC23 1SCA022659R7580 0.20
Interlocking device for locksCam attachment for Castell, Lowe & Fletcher or Ronis interlock. Lock not included. Direct mounting to the switch with OH-handle.
For switches Type Order number Weight [kg]
OETL-NFC200...1200 OETLZWC 1 1SCA022608R1420 1.1
OHB_
34
1SKC000006C0201
Transfer switches
Contact functions and dimension drawings
OETL-NFC200
l
O
45180
260
324
OZXK 12 or 13
162
137
Ø7
9x7
44
110
D F 3227 C
A
Ø B
4
102
45
110
126
OZXK 12 or 13
OETL-NFC200 OETL-NFC200-4
l
O
Ø7
9x7
110
D F 3227C
A
Ø B
102
45
M4
Ø66
125
36
162
137
44
I
22
I
22
OETL-NFC200OETL-NFC200-4
ØB F A C D
IShaft OXP 12x Mounting depth/L
185250325395465
328...401393...466468...541538...611608...681
L
OETL-NFC200_
237
155
OZXK 29
S0
15
03
A
11 25 285 177 56
16911 25 341 233 56 225
Contact functions for OETL-NFC200…1200
0 I I 0
S01
499A
0 II II 0
I-Position/ Primary network
II-Position/ Secondary networkLoad
Maincontacts I
Maincontacts II
Auxiliarycontact NO
Auxiliarycontact NC
Auxiliarycontact NO
Auxiliarycontact NC
35
1SKC000006C0201
Transfer switches
Dimension drawings
61215
315
40D
OZXK 1 or 2
( Upper and Lower Switch )
15
212
I
O 254
95
C 50 59
B
A
190
52,5
39,5
20
333
14
Ø9
OETL-NFC800OETL-NFC1200
12
15
I
O 254
95
C 50 59
B
A
190
52,5
39,5
20
333
14 Ø9
OETL-NFC800-4OETL-NFC1200-4
9x179x17
Ø66
175
361717
373373
I I
I
24 24
Shaft OXP 12x Mounting depth/L
185250325395465
364...437429...502504...577574...647644...717
L
297
195
OZXK 1 or 2
( Upper and Lower Switch )
S0
15
04
A
OETL-NFC800_...1200_
A B C D
OETL-NFC800 410 298 90 12OETL-NFC800-4 500 388 90 12OETL-NFC1200 410 298 90 16OETL-NFC1200-4 500 388 90 16
267357267357
Shaft OXP 12x Mounting depth/L
185250325395465
357...430422...495497...570567...640637...710
O
45
134
216
315
45H
I
C
E
Ø7
13x7
47
150
D F 32
B
A
ØG
H
120
55
140
172
A B C D E F G H I
316 208 216 70 185 40 13,5 5386 278 216 70 185 40 13,5 5358 253 216 90 185 40 13,5 5448 343 216 90 185 40 13,5 5
OETL-NFC400OETL-NFC400-4OETL-NFC600OETL-NFC600-4
OETL-NFC400_...OETL-NFC600_
Ø66
145
l
307
O
I
C
E
Ø7
13x7
47
150
D F
B
A
ØG
120
55
140
l
12
23 32
23
36
OETL-NFC400OETL-NFC600
OETL-NFC400-4OETL-NFC600-4
17 17
182252227317
L
295
165
OZXK 1 or 2(Upper and Lower Switch)
OZXK 1 or 2
( Upper and Lower Switch )OZXK 1 or 2
( Upper and Lower Switch )
S0
15
02
A
8
55
Ø1425
15
OETL-NFC800...1200
OETL-NFC400...600
36
Closed transition switches
The OESC range is a “make before break”
i.e. Closed Transition Transfer Switch type
that guarantees a transfer from the static
switch to the power line as manual bypass
switch and back again without any inter-
ruption.
This ensures equipment is powered, even
when maintenance work is carried out.
The OESC switches have double rated
neutral to withstand the thermal overload
from the harmonics, normally produced
by the UPS and added up in the neutral
conductor.
The range is UL 508 Recognized.
Maincontacts I
Maincontacts II
I-Position/ Primary network
II-Position/ Secondary networkLoad
Maintenance
bypass for UPS
Open transition switches
Technical data
37
1SKC000006C0201
Transfer switches
and contact functions
I II II I
S01
498A
Main
contacts I
Main
contacts II
Auxiliary
contact NO
Auxiliary
contact NC
I-Position/ Primary network
II-Position/ Secondary networkLoad
Contact functions for OESC250...500
1) Powerpoles 250 A; Neutral 400 A, with minimum cable cross section 240 mm2.2) Powerpoles 400 A; Neutral 630 A, with minimum cable cross section 2 x 185 mm2.
Data according to UL508 (Recognized)
Switch size OESC 250K_ 500K_ 250K04N2 400K04N2
General use
Voltage V 480 480 480 480
Current A 250 500 250 1) 400 2)
Short circuit current r.m.s kA 50 50 50 50
Data according to IEC 60947-3
Rated insulation voltage Pollution degr. 3 V 1 000 1 000 1000 1000
Dielectric strength 50 Hz 1min. kV 8 8 8 8
Rated impulse withstand voltage kV 12 12 12 12
Rated thermal current in ambient 40 ° C In open air A 250 500 250 400
...with minimum cable cross section Cu mm2 120 2x 120 120 240
Rated operational voltage AC-20 and DC-20 V 1 000 1 000 1000 1000
Rated operational current, AC-21A 500 V A 250 500 250 1) 400 2)
Rated operational current, AC-22A 500 V A 250 500 250 1) 400 2)
Rated conditional short-circuit current Ip (r.m.s.) I
p : 50 kA/ ≤ 500 V kA 42 42 42 42
and corresponding max. allowed cut-off
current îc, peak value.
Mechanical endurance Divide by two for Oper. 16 000 16 000 16 000 16 000
operation cycles
Terminal bolt size Diameter x length mm M10x40 M10x40 M10x40 M10x40
Terminal tightening torque Counter torque required Nm 30...44 30...44 30...44 30...44
Operating torque 3-pole switches Nm 30 30
38
1SKC000006C0201
Ordering information
S01
496A
21 21 1313
21 21 1313
21 21 1313
21 21 1313
S01
497A
21 21 1313
21 21 1313
S01
497A
S00
047A
OXP12X_
OZXK1...5
23 33
24 34
13 23 33 43
14 24 34 44
2no
4no
21 33
22 34
13 21 33 41
14 22 34 42
21 13
S01
275A
II
IS
0157
5A
External handles, IP 65, indication I - II The handles are equipped with door interlock function in II-position and when padlocked, only in I -position. Padlocking with 3 padlocks, bail dia Ø5...10 mm.
Padlocking possibility in I -position
For switches Colour Type Order number Weight [kg]
OESC 250...500 Black OHB175J12E16 1SCA022692R2080 0.17 Black OHB275J12E16 1SCA022690R0350 0.17
Extended shaftsFor switches Length [mm] Type Order number Weight [kg]
OESC 250…500 395 OXP12x395 1SCA022042R5990 0.45
465 OXP12x465 1SCA022042R6020 0.53
Auxiliary contacts
Wire cross section 0.5 mm2...2 x 2.5 mm2. Insulation voltage Ui 690 V. Thermal current I
th = 10 A. Pro-
tection degree IP 20. Contact functions, see the previous page.
Performance data according to IEC 60947-5-1
Ue /I
e (AC12):120V/8A, 240V/6A, 400V/4A, 415V/4A, 480V/3A, 500V/3A, 690V/2A,
Ue /I
e (DC12): 125V/1.1A, 250V/0.55A, 440V/0.31A, 500V/0.27A, 600V/0.2A.
Auxiliary contact For switch sizes Type Order number Weight [kg]
OESC OZXK 1 1SCA022131R8690 0.09
250...500
OESC OZXK 2 1SCA022131R8850 0.12
250...500
OESC OZXK 4 1SCA022131R9230 0.09
250...500
OESC OZXK 5 1SCA022131R9400 0.12
250...500
Transfer switches, 3-pole, I-II -operationThe switch includes a black handle IP65, see the table below, shaft and bolt set for the cable connec-tion. The bridging bars between the load supplies are also included.
Rated current I[A] AC-21A...AC-22A, 400V Type Order number Weight [kg]
250 OESC250K03 1SCA022700R2270 12.0500 OESC500K03 1SCA022700R2350 12.0
Transfer switches, 4-pole, I-II -operationThe switch includes a black handle IP65, shaft and bolt set for the cable connection. The bridging bars between the load supplies are also included.
Rated current I[A] AC-21A...AC-22A, 400V Type Order number Weight [kg]
250 OESC250K04 1SCA022700R2510 14.6500 OESC500K04 1SCA022700R2600 14.6
Transfer switches, 4-pole, double rated neutral, I-II -operationThe switch includes a black handle IP65, shaft and bolt set for the cable connection. The bridging bars between the load supplies are also included.
Rated current I[A] AC-21A...AC-22A, 400V Type Order number Weight [kg]
250/ 400 OESC250K04N2 1SCA022703R9940 15.2400/ 630 OESC400K04N2 1SCA022704R0010 15.2
OESC_K04
OESC_K03
OESC_K04N2
OH_
Shafts and handles included as standardThe handle is equipped with door interlock function in II-position and when padlocked, only in I -posi-tion. Padlocking with 3 padlocks, bail dia Ø 5...10 mm. Indication I-II.
For switches Shaft Handle Terminal bolt set
OESC 250...500 OXP12x250 OHB275J12E16 M10x40
Transfer switches
Ordering information
39
1SKC000006C0201
Transfer switchesDimension drawings
OESC250...500, 3-pole
OESC250...500, 4-pole
4 80
206
237
5 75
44
88 62Ø12 25
348
232
177119
30
230
210
76
177 166
30
Ø 7
S01510A
Ø 7
230
210
77
48
92 62 Ø12
380
410
232
177119
Ø 11
30
166 177
30
80
206
237
755
A A A B
OESC 250K04
OESC 500K04
OESC 250K04N2
OESC400K04N2
AxC
25x4
25x4
25x4
25x4
BxC
25x4
25x4
25x4
30x8
S0
15
11
A
C
40
Rotary change-over andbypass cam switches
The rotary cam switches are the
most space saving changeover
solutions, for the door and modular
base mounting.
The standard range includes a black
handle and fi nger protected termi-
nals. A large variation of front plates
for customized engraving enables
special cam switches.
Special cam switches can be con-
figurated on the Internet by the
Camweb confi gurator. The specifi -
cation and ordering of special cam
switches is as easy as selecting
standard products!
Technical data
41
1SKC000006C0201
Rotary change-over cam switches
Ratings according to IEC60947
Size OM ON OL40 OL80 OL125 OL160 OL200
Impuls withstand voltage Uimp
kV 2.5 4 6 6 6 6 6
Rated insulation voltage V 500 690 690 690 690 690 690
Rated operational voltage Ue
V 250 400 690 690 690 690 690
Rated thermal current Ith
A 10 25 45 115 150 175 280
Rated conditional short circuit current
Ip (r.m.s.) kA 1 - - - 5 5 10
Max back-up fuse link A 10 25 40 125 200 200 250
Rated short time withstand current (r.m.s)
3s A 100 360 800 1280 1280 1600
10s A 60 200 420 700 700 1000
30s A 32 120 260 400 400 600
60s A 30 80 160 280 280 400
Rated operational current Ie
A 10 25 45 115 150 160 250
AC1 400V A 10 25 45 115 150 170 250
AC21 400V A 10 25 45 115 150 170 250
AC11 220-240V A 2.5 5.5 14 30 45 45 80
380-440V A - 3.5 6.0 30 45 45 80
500V A - 4.5 7.0 28 40 40 70
AC22 220-500V A 10 20 40 100 150 170 250
660-690V A - 20 40 80 100 100 125
Rated operational current
Time constant 0...1ms DC1 24V A 10 20 40 115 130 150 250
48V A 6 10 20 100 115 130 200
60V A 2.5 3 5 - - - -
110V A 0.7 0.8 1 - - - -
220V A 0.3 0.4 0.6 - - - -
440V A - 0.22 0.25 - - - -
Rated operational current
Time constant 1...50 ms DC1 24V A 6 10 32 100 115 130 200
30V A 3 4.5 11 33 36 40 50
40V A 1 1.7 4 - - - -
60V A 0.7 0.8 1.5 - - - -
110V A 0.3 0.4 0.6 - - - -
Rated operational power
AC23 3 ph. 220-240V kW 1.8 2.6 7.5 30 37 37 56
380-440V kW 3 7.5 15 45 75 75 75
500V kW - 4.8 15 55 75 90 85
660-690V kW - 4.8 15 45 50 55 90
AC23 1 ph. 110V kW 0.37 0.5 2.5 5.5 9 11 14
220-240V kW 0.75 0.9 4 15 20 22 30
400V kW 1.1 1.5 7.5 22 35 37 45
Rated operational power
AC2 3 ph. 220-240V kW 2.5 3.5 11 30 35 37 70
380-440V kW - 6 18.5 45 50 55 95
500V kW - 6 18.5 55 65 75 103
660-690V kW - 6 18.5 55 65 55 110
42
1SKC000006C0201
Technical dataRotary change-over cam switches
Ratings according to IEC60947
Ratings according to UL and CSA
Size OM ON OL40 OL80 OL125 OL160 OL200
AC3 3 ph. 220-240V kW 1.8 2.2 7.5 15 20 22 47
380-440V kW 2.2 5.5 11 30 35 37 64
500V kW - 4 11 30 35 37 82
660-690V kW - 4 11 30 30 30 88
AC3 1 ph. 110V kW 0.3 0.4 2.5 3.7 6 6 12
220-240V kW 0.55 0.75 4.0 7.5 11 11 24
400V kW 0.75 1.3 5.5 13 19 19 40
Terminals
Size OM ON OL40 OL80 OL125 OL160 OL200
Connecting screws M 2.5 3.5 5 5 5 5 10
Max cable cross section mm2 1.5 4 6 70 70 70 150
AWG 14 14-12 14-8 12-2/0 12-2/0 12-2/0 kcmil
300
Size OM ON OL40 OL80 OL125 OL160 OL200
Maximum operating voltage V 300 600 600 600 600 600 600
Pilot duty
category
CSA/UL VAC A300 A600 A600 A600 A600 A600 A600
Ampere rating General use CSA A 10 25 40 80 125 170 200
at 600VAC UL A 10 25 40 80 125 170 200
Rated power 3-phase 120V HP 1 1 5 10 15 15 32
240V HP 1 2 10 30 40 40 64
480V HP - 5 20 30 40 50 120
600V HP - 5 20 30 40 50 120
1-phase 120V HP 0.33 1 2 7.5 10 10 -
240V HP 1 1 3 15 20 20 -
480V HP - 2 10 - - - -
600V HP - 3 10 - - - 10
Short cicuit ratings
Maximum prospective fault current kA 1 10 10 10 10 10 10
Maximum fuse size A 16 35(RK5) 50(RK3) 100(RK5) 150(RK5) 200(RK5) 250(RK5)
Switching frequency cycles/
hour
150 150 150 150 150 150 150
43
1SKC000006C0201
Rotary change-over cam switchesOrdering information
O_URR3_
O_URR1_
O_URR2_
O_U3_
Change-over switches
Black handle and front plate with position indication are included. The type and the ordering number are for one piece.
Function Number Rated Type Order number Delivery Weight/ of poles thermal batch unit current [pcs] [kg] I
th [A]
Step angle 60°, with 0-position
Door mounted
1 - 0 - 2 1 10 OMU1PB 1SCA022532R5960 10 0.09 2 10 OMU2PB 1SCA022532R6000 10 0.11 3 10 OMU3PB 1SCA022532R6180 10 0.13 4 10 OMU4PB 1SCA022532R6260 10 0.14
1 - 0 - 2 1 25 ONU1PB 1SCA022532R7310 10 0.09 2 25 ONU2PB 1SCA022532R7400 10 0.11 3 25 ONU3PB 1SCA022532R7580 10 0.13 4 25 ONU4PB 1SCA022532R7660 10 0.14
1 - 0 - 2 1 45 OL40U1PB 1SCA022761R0990 10 0.17 2 45 OL40U2PB 1SCA022761R1020 10 0.25 3 45 OL40U3PB 1SCA022761R1110 10 0.33 4 45 OL40U4PB 1SCA022761R1290 10 0.41
1 - 0 - 2 1 115 OL80U1RB 1SCA022790R0560 1 0.34 2 115 OL80U2RB 1SCA022790R0640 1 0.45 3 115 OL80U3RB 1SCA022790R0720 1 0.56 4 115 OL80U4RB 1SCA022790R0810 1 0.67
1 - 0 - 2 1 150 OL125U1RB 1SCA022790R1960 1 0.34 2 150 OL125U2RB 1SCA022790R2000 1 0.45 3 150 OL125U3RB 1SCA022790R2180 1 0.56 4 150 OL125U4RB 1SCA022790R2260 1 0.67
1 - 0 - 2 1 175 OL160U1RB 1SCA022790R6840 1 0.34 2 175 OL160U2RB 1SCA022790R6920 1 0.45 3 175 OL160U3RB 1SCA022790R7060 1 0.56 4 175 OL160U4RB 1SCA022790R7140 1 0.67
1 - 0 - 2 1 280 OL200U1RB 1SCA022790R7220 1 2.00 2 280 OL200U2RB 1SCA022790R7310 1 3.10 3 280 OL200U3RB 1SCA022790R7490 1 4.20 4 280 OL200U4RB 1SCA022790R7570 1 5.30
DIN-rail mounted
1 - 0 - 2 1 25 ONU1M 1SCA022532R8210 10 0.09 2 25 ONU2M 1SCA022532R8390 10 0.11 3 25 ONU3M 1SCA022532R8470 10 0.13 4 25 ONU4M 1SCA022534R2710 10 0.14
Key operated, with 0-position, withdrawable in all positions, step angle 60°
Door mounted
1 - 0 - 2 1 10 OMU1KB 1SCA022532R6340 10 0.07 3 10 OMU3KB 1SCA022532R6420 10 0.08
1 - 0 - 2 1 25 ONU1KB 1SCA022532R7740 10 0.12 3 25 ONU3KB 1SCA022532R7820 10 0.13
1R- 0 - 2
R , with two sided spring return, step angle 60°
Door mounted
1R
- 0 - 2R
1 10 OMURR1PB 1SCA022532R6510 10 0.05 3 10 OMURR3PB 1SCA022532R6690 10 0.06
1R
- 0 - 2R 1 25 ONURR1PB 1SCA022532R7910 10 0.09
2 25 ONURR2PB 1SCA022558R4040 10 0.11 3 25 ONURR3PB 1SCA022532R8040 10 0.12
1R
- 0 - 2R 1 45 OL40URR1PB 1SCA022761R1370 10 0.17
2 45 OL40URR2PB 1SCA022761R1450 10 0.25 3 45 OL40URR3PB 1SCA022761R1530 10 0.33
DIN-rail mounted
1R
- 0 - 2R 1 25 ONURR1M 1SCA022568R3530 10 0.09
O_U1_
O_U2_
O_U4_
Packing sizes for 10 pcs: OM 130 x 100 x 120 [mm]
ON, OL40 250 x 100 x 110 [mm]
44
1SKC000006C0201
Rotary change-over cam switchesOrdering information
O_WS1_
O_WS2_
O_WS3_
O_WS4_
Packing sizes for 10 pcs: OM 130 x 100 x 120 [mm]
ON, OL40 250 x 100 x 110 [mm]
Change-over switches
Black handle and front plate with position indication are included. The type and the ordering number are for one piece.
Function Number Rated Type Order number Delivery Weight/ of thermal batch unit poles current [pcs] [kg] I
th [A]
Without 0-position, step angle 60°
Door mounted
1 - 2 1 10 OMWS1PB 1SCA022532R6770 10 0.09 2 10 OMWS2PB 1SCA022532R6850 10 0.11 3 10 OMWS3PB 1SCA022533R0610 10 0.13 4 10 OMWS4PB 1SCA022533R0700 10 0.14
1 - 2 1 25 ONWS1PB 1SCA022532R8120 10 0.09 2 25 ONWS2PB 1SCA022532R9360 10 0.11 3 25 ONWS3PB 1SCA022532R9440 10 0.13 4 25 ONWS4PB 1SCA022532R9520 10 0.14
1 - 2 1 45 OL40WS1PB 1SCA022761R1610 10 0.17 2 45 OL40WS2PB 1SCA022761R1700 10 0.25 3 45 OL40WS3PB 1SCA022761R1880 10 0.33 4 45 OL40WS4PB 1SCA022761R1960 10 0.41
1 - 2 1 115 OL80WS1RB 1SCA022790R0990 1 0.34 2 115 OL80WS2RB 1SCA022790R1020 1 0.45 3 115 OL80WS3RB 1SCA022790R1110 1 0.56 4 115 OL80WS4RB 1SCA022790R1290 1 0.67
1 - 2 1 150 OL125WS1RB 1SCA022790R2340 1 0.34 2 150 OL125WS2RB 1SCA022790R2420 1 0.45 3 150 OL125WS3RB 1SCA022790R2510 1 0.56 4 150 OL125WS4RB 1SCA022790R2690 1 0.67
1 - 2 1 175 OL160WS1RB 1SCA022790R8030 1 0.34 2 175 OL160WS2RB 1SCA022790R8110 1 0.45 3 175 OL160WS3RB 1SCA022790R8200 1 0.56 4 175 OL160WS4RB 1SCA022790R8380 1 0.67
1 - 2 1 280 OL200WS1RB 1SCA022790R8460 1 2.00 2 280 OL200WS2RB 1SCA022790R8540 1 3.10 3 280 OL200WS3RB 1SCA022790R8620 1 4.20 4 280 OL200WS4RB 1SCA022790R8710 1 5.30
DIN-rail mounted
1 - 2 1 25 ONWS1M 1SCA022532R8710 10 0.09 2 25 ONWS2M 1SCA022532R8800 10 0.11 3 25 ONWS3M 1SCA022532R8980 10 0.13 4 25 ONWS4M 1SCA022532R9010 10 0.14
Wiring diagram (O_WS_)
45
1SKC000006C0201
Rotary change-over cam switchesOrdering information
Change-over switches
Black handle and front plate with position indication are included. The type and the ordering number are for one piece.
Function Number Rated Type Order number Delivery Weight/ of thermal batch unit poles current [pcs] [kg] I
th [A]
Door mounted
With overlapping contacts
1-2 1 10 OMWC1PB 1SCA022799R8270 10 0.09 2 10 OMWC2PB 1SCA022799R8600 10 0.11 3 10 OMWC3PB 1SCA022799R9080 10 0.13 4 10 OMWC4PB 1SCA022799R9160 10 0.14
1-2 1 25 ONWC1PB 1SCA022799R8350 10 0.09 2 25 ONWC2PB 1SCA022799R8780 10 0.11 3 25 ONWC3PB 1SCA022799R9240 10 0.13 4 25 ONWC4PB 1SCA022799R9320 10 0.14
1-2 1 45 OL40WC1PB 1SCA022799R8430 10 0.17 2 45 OL40WC2PB 1SCA022799R8860 10 0.25 3 45 OL40WC3PB 1SCA022799R9410 10 0.33 4 45 OL40WC4PB 1SCA022799R9590 10 0.41
1-2 1 115 OL80WC1RB 1SCA022799R8510 1 0.34 2 115 OL80WC2RB 1SCA022799R8940 1 0.45 3 115 OL80WC3RB 1SCA022799R9670 1 0.56 4 115 OL80WC4RB 1SCA022799R9750 1 0.67
With common center position and with overlapping contacts
1 - (1 + 2) - 2 3 25 ONUC3PB 1SCA022791R0360 10 0.13 4 25 ONUC4PB 1SCA022791R0280 10 0.14
1 - (1 + 2) - 2 3 45 OL40UC3PB 1SCA022791R0870 10 0.13 4 45 OL40UC4PB 1SCA022791R0950 10 0.14
1 - (1 + 2) - 2 3 115 OL80UC3RB 1SCA022791R1410 1 0.56 4 115 OL80UC4RB 1SCA022791R1920 1 0.67
1 - (1 + 2) - 2 3 150 OL125UC3RB 1SCA022791R1500 1 0.56 4 150 OL125UC4RB 1SCA022791R2060 1 0.67
1 - (1 + 2) - 2 3 175 OL160UC3RB 1SCA022791R1680 1 0.56 4 175 OL160UC4RB 1SCA022791R2140 1 0.67
1 - (1 + 2) - 2 3 280 OL200UC3RB 1SCA022791R1760 1 4.20 4 280 OL200UC4RB 1SCA022791R2220 1 5.30
Wiring diagram (O_WC_, O_UC_)
Packing sizes for 10 pcs: OM 130 x 100 x 120 [mm]
ON, OL40 250 x 100 x 110 [mm]
O_WC1_
O_WC2_
O_WC3_
O_WC4_
O_UC3_
O_UC4_
46
1SKC000006C0201
Rotary change-over cam switchesOrdering information
Packing sizes for 10 pcs: OM 130 x 100 x 120 [mm]
ON, OL40 250 x 100 x 110 [mm]
Bypass switches
Black handle and front plate with position indication are included. The type and the ordering numberare for one piece.
Function Number Rated Type Order number Delivery Weight/ of thermal batch unit poles current [pcs] [kg] I
th [A]
Door mounted
Without overlapping, 3 and 4- pole network
1 - 0 - Bypass 3 / 6 25 ONWS36PB 1SCA022791R0440 10 0.17 4 / 8 25 ONWS48PB 1SCA022791R0520 10 0.19
1 - 0 - Bypass 3 / 6 45 OL40WS36PB 1SCA022791R1090 10 0.21 4 / 8 45 OL40WS48PB 1SCA022791R1170 10 0.31
1 - 0 - Bypass 3 / 6 115 OL80WS36RB 1SCA022791R2490 1 0.78 4 / 8 115 OL80WS48RB 1SCA022791R2900 1 0.89
1 - 0 - Bypass 3 / 6 150 OL125WS36RB 1SCA022791R2570 1 0.78 4 / 8 150 OL125WS48RB 1SCA022791R3030 1 0.89
1 - 0 - Bypass 3 / 6 175 OL160WS36RB 1SCA022791R2650 1 0.78 4 / 8 175 OL160WS48RB 1SCA022791R3110 1 0.89
1 - 0 - Bypass 3 / 6 280 OL200WS36RB 1SCA022791R2730 1 6.40 4 / 8 280 OL200WS48RB 1SCA022791R3200 1 7.50
With overlapping, 3 and 4- pole network
1 - Bypass 3 / 6 25 ONPW36PB 1SCA022791R0610 10 0.17 4 / 8 25 ONPW48PB 1SCA022791R0790 10 0.19
1 - Bypass 3 / 6 45 OL40PW36PB 1SCA022791R1250 10 0.21 4 / 8 45 OL40PW48PB 1SCA022791R1330 10 0.31
1 - Bypass 3 / 6 115 OL80PW36RB 1SCA022791R3460 1 0.78 4 / 8 115 OL80PW48RB 1SCA022791R3970 1 0.89
1 - Bypass 3 / 6 150 OL125PW36RB 1SCA022791R3540 1 0.78 4 / 8 150 OL125PW48RB 1SCA022791R4010 1 0.89
1 - Bypass 3 / 6 175 OL160PW36RB 1SCA022791R3620 1 0.78 4 / 8 175 OL160PW48RB 1SCA022791R4190 1 0.89
1 - Bypass 3 / 6 280 OL200PW36RB 1SCA022791R3710 1 6.40 4 / 8 280 OL200PW48RB 1SCA022791R4270 1 7.50
Wiring diagram, bypass switches
O_WS36_
O_WS48_
O_PW36_
O_PW48_
Phase 1 Phase 4Phase 3Phase 2
O_WS36_, O_PW36_
O_WS48_, O_PW48_
47
1SKC000006C0201
AccessoriesOrdering information
ONPB1
OMPB1 OMPG1
ONXB1OMXB1
Handles The type and the ordering number are for one piece.
Colour For cam switches Type Oder Number Delivery Weight/ batch unit [pcs] [kg]
Snap on handle with front plate without engraving(The black handle is standard delivery in types OM, ON, and OL40)
Size 30x30
Black OM OMPB1 1SCA022553R7470 5 0.05Gray OM OMPG1 1SCA022553R8010 5 0.05Red OM OMPR1 1SCA022796R2830 5 0.05Red-yellow OM OMPRY1 1SCA022796R2910 5 0.05
Size 48x48
Black ON_PB, OL40 ONPB1 1SCA022553R7550 5 0.08Gray ON_PB, OL40 ONPG1 1SCA022553R7630 5 0.08Red ON_PB, OL40 ONPR1 1SCA022796R3050 5 0.08Red-yellow ON_PB, OL40 ONPRY1 1SCA022796R3130 5 0.08
Snap on handle with large front plate without engraving
Size 64x64
Black ON_PB, OL40 ONPLB1 1SCA022776R5680 5 0.10Gray ON_PB, OL40 ONPLG1 1SCA022776R5760 5 0.10Red ON_PB, OL40 ONPLR1 1SCA022776R5840 5 0.10Red-yellow ON_PB, OL40 ONPLRY1 1SCA022796R3130 5 0.10
Screw mounting handle with front plate without engraving(The black handle is standard delivery in types OL 80...200)
Size 90x90
Black OL80, OL125, OL160 OLR2B 1SCA022796R3720 10 0.10Gray OL80, OL125, OL160 OLR2G 1SCA022796R3810 10 0.10Red OL80, OL125, OL160 OLR2R 1SCA022796R3990 10 0.10
Size 130x130
Black OL200 OLR3B 1SCA022796R4110 10 0.10Gray OL200 OLR3G 1SCA022796R4290 10 0.10Red OL200 OLR3R 1SCA022796R4370 10 0.10
Snap on handle with round escutheon plate
Black OM OMXB1 1SCA022629R7270 5 0.02Black, nose-type OM OMXNB1 1SCA022577R9810 5 0.02Black ON_PB, OL40 ONXB1 1SCA022629R7350 5 0.02
More cam switches with padlockable handles can be confi gurated on Internet by the Camweb confi gurator tool.
ONPLB1 OLR2B, OLR3B
ONPG1
48
1SKC000006C0201
Optional handles The type and the ordering number are for one piece.
Colour For cam switches Type Oder Number Delivery Weight/ batch unit [pcs] [kg]
Hand grip handle, screw mounting
Black OLHSD1 1SCA022765R2480 Gray OLHGD1 1SCA022765R2560 Red OLHRD1 1SCA022765R2640
Ball grip handle, screw mounting
Black OLISD1 1SCA022820R3380 Gray OLIGD1 1SCA022820R3460 Red OLIRD1 1SCA022820R3540
Pistol type handle, screw mounting
Black OL80, OL125, OL160 OLZ2RB 1SCA022796R4530 10 0.10Red OL80, OL125, OL160 OLZ2RR 1SCA022796R4610 10 0.10Black OL200 OLZ3RB 1SCA022796R4700 10 0.2Red OL200 OLZ3RR 1SCA022796R4880 10 0.2
Double lever handle, screw mounting
Black OL200 OLZ3DB 1SCA022796R4960 1 0.3Red OL200 OLZ3DR 1SCA022796R5000 1 0.3
Padlockable handle knob, without front plate
The standard handle knob is replaced by the padlockable handle knob. For max 2 padlocks of 6 mm hasp diameter. Standard padlocking in the OFF-position at 9 o’clock. Padlocking in the ON-position (12 o’clock) by turning the control piece 180 degrees. Padlocking in both OFF-and ON-positions by removing a precut in the yellow control piece.
Black ON_PB, ON_M, OL40 ONZ20B 1SCA022621R1810 5 0.06 Red-yellow ON_PB, ON_M, OL40 ONZ20RY 1SCA022621R1900 5 0.06
Round padlockable handle for srew mounting on door
For max 3 padlocks with max 8 mm hasp diameter, locking position 9 o’clock (O, OFF) and positions 12 o’clock (1, ON) when switch rotated. More locking possibilities with programmable square handle type _ 5 _ can be specifi ed by the Camweb tool.
Size 64x64, shaft size 6 mm
Black ON_PB, OL40 ONZ331PB 1SCA022794R7520 10 0.035Red-yellow ON_PB, OL40 ONZ331PRY 1SCA022794R7610 10 0.035
Size 90x90, shaft size 8 mm
Black OL80, OL125, OL160 OLZ332RB 1SCA022794R7790 10 0.10Red-yellow OL80, OL125, OL160 OLZ332RRY 1SCA022794R7870 10 0.10
OLZ2RB
OLZ3RB
OLZ3DB
ONZ20B
ONZ331PB ONZ332RRY
ONZ20RY
OLHSD1
OLISD1
AccessoriesOrdering information
More cam switches with padlockable handles can be confi gurated on Internet by the Camweb confi gurator tool.
49
1SKC000006C0201
AccessoriesOrdering information
Front plates The type and the ordering number are for one piece.
Colour For cam switches/ Type Order Number Delivery Weight/ handle size batch unit [pcs] [kg]
Front plates, without engraving
Size 30x30
Silver OM/OMP_1 OMF101 1SCA022540R4590 10 0.003Yellow OM/OMPR41 OMFY101 1SCA022796R3210 10 0.003
Size 48x48
Silver ON_PB, OL 40/ONP_1 ONF101 1SCA022540R6290 10 0.003Yellow ON_PB, OL 40/ONPRY1 ONFY101 1SCA022716R4250 10 0.003
Size 64x64
Silver ONPL_1 OLF64 1SCA022798R6260 10 0.003Yellow ONPLR41 OLF464 1SCA022798R6340 10 0.003
Size 90x90
Silver OL80, OL125, OL160/OLR2_ OLF90 1SCA022796R5180 10 0.01Yellow OL80, OL125, OL160/OLR2_ OLFY90 1SCA022796R5260 10 0.01
Size 130x130
Silver OL200/OLR3_ OLF130 1SCA022796R5420 10 0.01Yellow OL200/OLR3_ OLFY130 1SCA022796R5340 10 0.01
Size H=45mm, W=54mm
Grey ON_M ONFM 101 1SCA022553R8520 10 0.01
Additional lettering plates
Without engraving, black engraving from front side available.
Size 30x30
Black frame OM OMFB72 1SCA022555R4990 5 0.01Grey frame OM OMFG72 1SCA022556R1850 5 0.01
Size 48x48
Black frame ON_PB, OL 40 ONFB72 1SCA022555R5020 5 0.01Grey frame ON_PB, OL 40 ONFG72 1SCA022556R1930 5 0.01
Size 64x64
Black frame ON_PB, OL 40 OLFB64 1SCA022796R3300 10 0.01Grey frame ON_PB, OL 40 OLFG64 1SCA022796R3480 10 0.01
Front ring
Black OM OMX99 1SCA022553R8100 10 0.01Black ON_PB, OL40 ONX99 1SCA022553R7710 10 0.01
Shaft sealing
To prevent dust and moisture penetrating along the switch shaft when no handle is installed. Protection to IP 65 from the front. Door drilling 16...17 mm.
For cam switches Type Order Number Delivery Weight batch [kg] [pcs]
ON, OL40 ONZ11 1SCA022807R0300 10 0.01OL 80...160 OLZ12 1SCA022807R0560 10 0.01
ONFM101
OMF101 ONF101
OMX99 ONX99
ONF64
OMFB72 ONFB72
ONFB64
OLF90
50
1SKC000006C0201
AccessoriesOrdering information
OMK95
ONX30
OMNX80
ONZ10L_
ONK95
ONZ74_
Other accessories The type and the ordering number are for one piece.
Spare key
Number of For cam switches Type Order number Delivery Weightkeys batch [kg] included [pcs]
2 pcs OM OMK95 1SCA022553R8360 2 0.013 pcs ON, OL40 ONK95 1SCA022553R7980 2 0.01
Protective rear coverTransparent, IP 42 protection
Number Number For cam Type Order number Delivery Weightof of switches batch [kg] chambers contacts [pcs]
1-2 2-4 ON ONZ10L2 1SCA022621R1570 1 0.023-4 6-8 ON ONZ10L4 1SCA022621R1650 1 0.045-6 10-12 ON ONZ10L6 1SCA022621R1730 1 0.06
2 OL40 OLZ401L2 1SCA022805R9910 1 4 OL40 OLZ401L4 1SCA022806R0090 16 OL40 OLZ401L6 1SCA022806R0170 1
2 OL80...160 OLZ1601L2 1SCA022806R0250 1 4 OL80...160 OLZ1601L4 1SCA022806R0330 16 OL80...160 OLZ1601L6 1SCA022806R0410 1
Nut spanner
for mounting the handle to the door
Colour For cam switches Type Order number Delivery Weight batch [kg] [pcs]
OM OMNX80 1SCA022553R8440 1 0.02Black ON
Adaptor ring
for fi xing the snap-on handles in the 30 mm door drilling.
Black ON ONX30 1SCA022643R8510 10 0.01
Base mounting kit
Includes base for DIN-rail mounting, shaft adaptor and 200 mm shaft for cutting up to 250 mm panel depth.
Depth [mm] For cam switches Type Order number
250 ON ONZ74 1SCA022757R3510 0.05
DIN-Rail mounting plate
Includes base for DIN-rail mounting.
ON ONZ37 1SCA022789R8810 1 0.02
Door coupling kits for base mounting switches
for snap-on mounted handle.
ON, OL40 ONZ45P 1SCA022819R5850 1 0.01
for screw mounted handle.
OL80...160 OLZ652 1SCA022819R5930 1 0.02 OL200 OLZ653 1SCA022819R6070 1 0.02
ONZ37
ONZ45P
ONZ65_
51
1SKC000006C0201
22,3
3,2
24,1
+ 0,4
+ 0,4
+ 0,2
16,2
1,7
17,9
+ 0,2
+ 0,2
+ 0,2
S0
11
58
Ag
b
30
30
12
22
Door thickness
max. 5,5 mm
27x28
L
21,5
28
51,5
7
12
Door thickness
max. 5,5 mm
L25
27x28
8
Ø3,2
20Screw mounted handle(special)
Rotary change-over cam switchesDimension drawings
OM
ON
Number of contact chambers
1 2 3 4 5 6 7 8 9 10
Snap-on mounting (P type) L 54 66 78 90 102 114 126 138 150 162
Screw mounting (R type) L 34 46 58 70 82 94 106 118 130 142
H 62 74 86 98 110 122 134 146 159 171
Number of contact chambers
1 2 3 4 5 6 7 8
Snap-on mounting (P type) L 45 57 69 81 90 105 117 129
Screw mounting (R type) L 33 45 57 69 81 93 105 117
52
1SKC000006C0201
OL40, door mounted with snap-on mounting handle
Number of contact chambers
1 2 3 4 5 6 7 8 9 10
L 59 72 85 98 111 124 137 150 163 176
ON_M
Non-modular: number of contact chambers
2 3 4 5 6 7 8
L 58 70 82 94 106 118 130
45
53
35
1716125
39x41
46 13,5
S00
1159
A
Rotary change-over cam switchesDimension drawings
53
1SKC000006C0201
Rotary change-over cam switchesDimension drawings
OL80, OL125, OL160 door mounted
Number of contact chambers
1 2 3 4 5 6 7 8 9 10
L 66 97 128 159 190 221 252 283 314 345
OL200 door mounted
Number of contact chambers
1 2 3 4 5 6 7 8 9 10
L 120 181 242 303 364 425 486 547 608 669
Notes
54
1SKC000006C0201
Notes
55
1SKC000006C0201
ABB Oy
Low Voltage ProductsP.O. Box 622FI-65101 VAASA, FinlandTelephone +358 10 22 11Telefax +358 10 22 45708www.abb.com/lvswitches
The technical data and dimensions are valid at the time of printing. We reserve the right to subsequent alterations.
Cata
log
ue O
T_O
ET
L2G
B 0
6_06
1S
CC
301007C
0201
The operations of the manufacturing plant have been certifi ed.
Pri
nte
d b
y:
Waasa G
rap
hic
s O
y, V
aasa F
inla
nd
Pro
du
cte
d b
y: C
itec In
form
ati
on
OY, Vaasa F
inla
nd