ABBOfflineOrderNumberTool_Ver_15.41b_758059_ENg.xls

75
ABB Oy, Distribution Automation P.O. Box 699 FI-65101 VAASA, Finland ABB Distribution Automation Protection Relay Price List This Excel workbook contains and relies on mac In order for this workbook to operate correctly m In Excel 2010, press the ENABLE CONTENT butto In Excel 2007, press the OPTIONS button below t In earlier versions of Excel, choose to enable ma

Transcript of ABBOfflineOrderNumberTool_Ver_15.41b_758059_ENg.xls

Page 1: ABBOfflineOrderNumberTool_Ver_15.41b_758059_ENg.xls

ABB Oy, Distribution Automation

P.O. Box 699

FI-65101 VAASA, Finland

ABB Distribution Automation

Protection Relay Price List

This Excel workbook contains and relies on macros.

In order for this workbook to operate correctly macros MUST be enabled.

In Excel 2010, press the ENABLE CONTENT button below the ribbon and enable the macro contents.

In Excel 2007, press the OPTIONS button below the ribbon and enable the macro contents.

In earlier versions of Excel, choose to enable macros when asked for when the file is opened.

Page 2: ABBOfflineOrderNumberTool_Ver_15.41b_758059_ENg.xls

This Excel workbook contains and relies on macros.

In order for this workbook to operate correctly macros MUST be enabled.

In Excel 2010, press the ENABLE CONTENT button below the ribbon and enable the macro contents.

In Excel 2007, press the OPTIONS button below the ribbon and enable the macro contents.

In earlier versions of Excel, choose to enable macros when asked for when the file is opened.

Page 3: ABBOfflineOrderNumberTool_Ver_15.41b_758059_ENg.xls

ABB Medium Voltage Products Offline Order Number ToolVer. 15.41b

Relion© Other IED's and equipment

Feeder Protection and Control / Feeder Protection Recloser Protection and Control

Self-powered Feeder Protection Remote Monitoring and Control

Feeder Protection and Control Remote I/O Unit

Motor Protection and Control Wireless Controller

Busbar and Multipurpose Differential Protection and Control Wireless Gateway

Feeder Protection and Control Remote Terminal Unit

Motor Protection and Control Feeder Terminal

Transformer Protection and Control Machine Terminal

Line Differential Protection and Control Transformer Terminal

Voltage Protection and Control Feeder Terminal

Capacitor Bank Protection and Control Arc Protection

Feeder Protection and Control Protection IED

Motor Protection and Control Annunciator Unit

Transformer Protection and Control Remote Monitoring and Control Unit

Feeder Protection and Control Bus Connection Module and Protocol Converter

Motor Protection and Control Programing and Connection Cables

Transformer Protection and Control Mounting Accessories for SPACOM, SACO and RE_5__

Generator Protection and Control

Feeder Protection

Motor Protection

Voltage Protection and Control

Station Automation Devices

Programing Tool

Power Management

REF615

REM615

RET615

RED615

REU615

REF630

REM630

RET630

REF610

REM610

REU610

REF 541, REF 543, REF 545

REM 543, REM 545

RET 541, RET 543, RET 545

REF542plus

REA 101

SPACOM

SACO

REC 523

COM600

RER, SPA-ZC

PCM600

SPA-ZP

SPA-ZX

User's Guide

REB611

REM611

REF611 RIO600

REC601, REC603

RER601, RER603

REG630

REF601, REJ601

REJ603

RTU

REF620

REM620

RET620

REC615

RER615

PML630

REV615

Page 4: ABBOfflineOrderNumberTool_Ver_15.41b_758059_ENg.xls

ABB Oy, Distribution Automation

P.O. Box 699

FI-65101 VAASA, Finland

ABB Medium Voltage Products

Offline Order Number Tool

Price List for:

Validity: From 2013-12-01

Until 2013-12-01

Terms and Conditions:

ABB customers:

ABB internal customer:

Currency: All shown prices are in currency EUR

Order codes:

Disclaimer: Please be aware, that this Excel file is a price list and not a product configurator with

complete selection rules. This means that in some cases also not possible order codes may

be generated and prices for these. We do not take any liability for against the in the Product

Guides given selection rules generated order codes and possible prices for these codes.

Terms and Conditions according a signed supply agreement

between your company and local ABB unit.

Order codes, how to define the order codes for configurable

products (e.g. 615 series) and technical information can be found in the for each

product related Product Guide. http://www.abb.com/substationautomation

We keep the right to adjust the prices and technical data without any prenotification when

there are changes in products and/or mistakes are found in the price list.

Terms and Conditions and prices according those given in

CCP/Selectica.

Page 5: ABBOfflineOrderNumberTool_Ver_15.41b_758059_ENg.xls

ABB Medium Voltage Products

Offline Order Number Tool

Instructions

1.

2.

3.

4.

Order number parts can also be selected by single-clicking a code value in the table.

Accessories for configurable products can be found below the order number table.

Configurable products with order numbers have the order number displayed at the top of the page.

Yellow parts of the order number are fixed and cannot be changed.

Green parts of the order number are configurable and can be selected from the drop-down list.

Page 6: ABBOfflineOrderNumberTool_Ver_15.41b_758059_ENg.xls

REF601 / REJ601Feeder Protection and Control / Feeder Protection

Selected Order No. 46 1 H

Instructions / Order No. Start Pos. 1 2 3/4 5/6 7 8 9 10 11

Relay type

REF601 - Feeder protection with control REF601

REJ601 - Feeder protection w/o control REJ601

Standard

IEC B

CEI J

Analog input / output

3 sensor and ground current input A4

Phase and Earth current input - 1A D4

Phase and Earth current input - 5A E4

Binary input / output

4 BI + 6 BO 46

Serial communication

MODBUS B

IEC103 C

None N

Application configuration

Configuration 2 B

Configuration 3 C

Configuration 4 Only for REF601 D

Power supply

24...240V AC / DC 1

Configuration

Ring terminal Not available when Order No. 3/4 = A4 B

Screw terminal N

Version

Product version 2.2 FP1 H

Communication Accessories Order No.

RE_601 communication card CIM601BNNNNBANXH

Page 7: ABBOfflineOrderNumberTool_Ver_15.41b_758059_ENg.xls

REJ603Self-Powered Feeder Protection

Price

Item Order No. Description EUR

REJ603BB401NN31E REJ603BB401NN31E REJ603 with HMI 0

REJ603BB401NN3XE REJ603BB401NN3XE REJ603 without HMI 0

REJ603BNNNNNNBZA REJ603BNNNNNNBZA Add-on HMI kit 0

Current transformer

CT typeSetting range of

reference current “Is”

REJ603-CT1 8 - 28A

REJ603-CT2 16 - 56 A

REJ603-CT3 32 - 112 A

REJ603-CT4 64 - 224 A

REJ603-CT5 128 - 448 A

Note: The REJ603 requires specific ring CT’s to be used for phase current measurement. It is

not compatible with conventional 1 A/ 5 A CT’s. The primary current setting range is adequately

covered by following 5 variants of CT’s .

For further technical information on current transformers and ordering information, please refer

to the datasheet of CT reference no. 1YMA583791R0001-4.

Page 8: ABBOfflineOrderNumberTool_Ver_15.41b_758059_ENg.xls

REF611Feeder Protection and Control

Selected Order No. RE F 611 B X E

Instructions / Order No. Pos. 1/2 3 4/5/6 7 8 9 10 11 12 13 14 15 16 17 18 EUR

Product

IED (Relay) RE

Main application

Feeder protection and control F

IED series

611 series IED 611

IED casing and test switches

Complete relay H

Complete relay with test switch installed and wired in 19’’ cover plate, for

standar configuration AAdditional price for configuration A K

Complete relay with test switch installed and wired in 19’’ cover plate, for

standar configuration BAdditional price for configuration B K

Complete relay with test switch installed and wired for 4U Combilfex rack

mounting, for standar configuration AAdditional price for configuration A L

Complete relay with test switch installed and wired for 4U Combilfex rack

mounting, for standar configuration AAdditional price for configuration B L

Standard

IEC B

Standard configuration

A = Non-directional O/C and directional E/F A

B = Non-directional O/C and non-directional E/F B

AIM I0 Analog inputs

1A / 5A A

0.2A / 1A B

Communication module

Ethernet 100Base FX (LC) Additional price A

Ethernet 100Base TX (RJ45) Additional price B

RS485 (including IRIG-B) Additional price C

Ethernet 100Base TX (3*RJ45) Additional price D

None N

Communication protocols

IEC61850 A

Modbus Additional price B

Language

English 1

English and Chinese 2

English and Spanish 5

English and Polish 7

English and French C

English and Czech E

Option 1

Auto-reclosing Additional price A

None N

Option 2

Optional I/O (X130) Additional price A

None N

Power supply

48...250 V DC, 100...240 V AC 1

24…60 V DC 2

For future use

Undefined X

Version

Page 9: ABBOfflineOrderNumberTool_Ver_15.41b_758059_ENg.xls

REF611Feeder Protection and Control

Selected Order No. RE F 611 B X E

Instructions / Order No. Pos. 1/2 3 4/5/6 7 8 9 10 11 12 13 14 15 16 17 18 EUR

Product version 1.0 E

Mounting accessories for REF611 Order No.

Semi-flush mounting kit 1MRS050696

Wall mounting kit 1MRS050697

Inclined semi-flush mounting kit 1MRS050831

19” rack mounting kit with cut-out for one IED 1MRS050694

19” rack mounting kit with cut-out for two IEDs 1MRS050695

Mounting bracket for one IED with test switch RTXP in 4U Combiflex

(RHGT 19” variant C)2RCA022642P0001

Mounting bracket for one IED in 4U Combiflex (RHGT 19” variant C) 2RCA022643P0001

19” rack mounting kit for one IED and one RTXP18 test switch (the

test switch is not included in the delivery)2RCA021952A0003

19” rack mounting kit for one IED and one RTXP24 test switch (the

test switch is not included in the delivery)2RCA022561A0003

Price

EUR

0

0

0

0

0

0

0

0

0

Page 10: ABBOfflineOrderNumberTool_Ver_15.41b_758059_ENg.xls

REM611Motor Protection and Control

Selected Order No. RE M 611 B A N N X E

Instructions / Order No. Pos. 1/2 3 4/5/6 7 8 9 10 11 12 13 14 15 16 17 18 EUR

Product

IED (Relay) RE

Main application

Motor protection and control M

IED series

611 series IED 611

IED casing and test switches

Complete relay H

Complete relay with test switch installed and wired in 19’’ cover plate Additional price K

Complete relay with test switch installed and wired for 4U Combilfex rack

mountingAdditional price L

Standard

IEC B

Standard configuration

Motor protection A

AIM I0 Analog inputs

1A / 5A A

0.2A / 1A B

Communication module

Ethernet 100Base FX (LC) Additional price A

Ethernet 100Base TX (RJ45) Additional price B

RS485 (including IRIG-B) Additional price C

Ethernet 100Base TX (3*RJ45) Additional price D

None N

Communication protocols

IEC61850 A

Modbus Additional price B

Language

English 1

English and Chinese 2

English and Spanish 5

English and Polish 7

English and French C

English and Czech E

Option 1

None N

Option 2

None N

Power supply

48...250 V DC, 100...240 V AC 1

24…60 V DC 2

For future use

Undefined X

Version

Product version 1.0 E

Mounting accessories for REF611 Order No.

Price

EUR

Page 11: ABBOfflineOrderNumberTool_Ver_15.41b_758059_ENg.xls

REM611Motor Protection and Control

Selected Order No. RE M 611 B A N N X E

Instructions / Order No. Pos. 1/2 3 4/5/6 7 8 9 10 11 12 13 14 15 16 17 18 EUR

Semi-flush mounting kit 1MRS050696

Wall mounting kit 1MRS050697

Inclined semi-flush mounting kit 1MRS050831

19” rack mounting kit with cut-out for one IED 1MRS050694

19” rack mounting kit with cut-out for two IEDs 1MRS050695

Mounting bracket for one IED with test switch RTXP in 4U Combiflex

(RHGT 19” variant C)2RCA022642P0001

Mounting bracket for one IED in 4U Combiflex (RHGT 19” variant C) 2RCA022643P0001

19” rack mounting kit for one IED and one RTXP18 test switch (the

test switch is not included in the delivery)2RCA021952A0003

19” rack mounting kit for one IED and one RTXP24 test switch (the

test switch is not included in the delivery)2RCA022561A0003

0

0

0

0

0

0

0

0

0

Page 12: ABBOfflineOrderNumberTool_Ver_15.41b_758059_ENg.xls

REB611Busbar and Multipurpose Differential Protection and Control

Selected Order No. RE B 611 B A N N X E

Instructions / Order No. Pos. 1/2 3 4/5/6 7 8 9 10 11 12 13 14 15 16 17 18 EUR

Product

IED (Relay) RE

Main application

Busbar and multipurpose differential protection and control B

IED series

611 series IED 611

IED casing and test switches

Complete relay H

Complete relay with test switch installed and wired in 19’’ cover plate Additional price K

Complete relay with test switch installed and wired for 4U Combilfex rack

mountingAdditional price L

Standard

IEC B

Standard configuration

High impedance differential A

AIM I0 Analog inputs

1A / 5A A

0.2A / 1A B

Communication module

Ethernet 100Base FX (LC) Additional price A

Ethernet 100Base TX (RJ45) Additional price B

RS485 (including IRIG-B) Additional price C

Ethernet 100Base TX (3*RJ45) Additional price D

None N

Communication protocols

IEC61850 A

Modbus Additional price B

Language

English 1

English and Chinese 2

English and Spanish 5

English and Polish 7

English and French C

English and Czech E

Option 1

None N

Option 2

None N

Power supply

48...250 V DC, 100...240 V AC 1

24…60 V DC 2

For future use

Undefined X

Version

Product version 1.0 E

Mounting accessories for REF611 Order No.

Semi-flush mounting kit 1MRS050696

Wall mounting kit 1MRS050697

Price

EUR

0

0

Page 13: ABBOfflineOrderNumberTool_Ver_15.41b_758059_ENg.xls

REB611Busbar and Multipurpose Differential Protection and Control

Selected Order No. RE B 611 B A N N X E

Instructions / Order No. Pos. 1/2 3 4/5/6 7 8 9 10 11 12 13 14 15 16 17 18 EUR

Inclined semi-flush mounting kit 1MRS050831

19” rack mounting kit with cut-out for one IED 1MRS050694

19” rack mounting kit with cut-out for two IEDs 1MRS050695

Mounting bracket for one IED with test switch RTXP in 4U Combiflex

(RHGT 19” variant C)2RCA022642P0001

Mounting bracket for one IED in 4U Combiflex (RHGT 19” variant C) 2RCA022643P0001

19” rack mounting kit for one IED and one RTXP18 test switch (the

test switch is not included in the delivery)2RCA021952A0003

19” rack mounting kit for one IED and one RTXP24 test switch (the

test switch is not included in the delivery)2RCA022561A0003

0

0

0

0

0

0

0

Page 14: ABBOfflineOrderNumberTool_Ver_15.41b_758059_ENg.xls

REF615Feeder Protection and Control

Selected Order No. B F X G

Instructions / Order No. Pos. 1 2 3 4 5/6 7/8 9 10 11 12 13 14 15 16 17 18 EUR

IED

Complete Relay H

Complete Relay with test switch installed and wired in 19'' cover plate.

Note! Not available for standard configuration "G" and "L".Additional price for configurations A and B K

Complete Relay with test switch installed and wired in 19'' cover plate.

Note! Not available for standard configuration "G" and "L".Additional price for configurations C and D K

Complete Relay with test switch installed and wired in 19'' cover plate.

Note! Not available for standard configuration "G" and "L".Additional price for configurations E and F K

Complete Relay with test switch installed and wired in 19'' cover plate.

Note! Not available for standard configuration "G" and "L".Additional price for configuration H K

Complete Relay with test switch installed and wired in 19'' cover plate.

Note! Not available for standard configuration "G" and "L".Additional price for configuration J K

Complete Relay with test switch installed and wired in 19'' cover plate.

Note! Not available for standard configuration "G" and "L".Additional price for configuration K K

Complete Relay with test switch installed and wired in 19'' cover plate.

Note! Not available for standard configuration "G" and "L".Additional price for configuration N K

Complete Relay with test switch installed and wired for CombiFlex rack mounting.

Note! Not available for standard configuration "G" and "L".Additional price for configurations A and B L

Complete Relay with test switch installed and wired for CombiFlex rack mounting.

Note! Not available for standard configuration "G" and "L".Additional price for configurations C and D L

Complete Relay with test switch installed and wired for CombiFlex rack mounting.

Note! Not available for standard configuration "G" and "L".Additional price for configurations E and F L

Complete Relay with test switch installed and wired for CombiFlex rack mounting.

Note! Not available for standard configuration "G" and "L".Additional price for configuration H L

Complete Relay with test switch installed and wired for CombiFlex rack mounting.

Note! Not available for standard configuration "G" and "L".Additional price for configuration J L

Complete Relay with test switch installed and wired for CombiFlex rack mounting.

Note! Not available for standard configuration "G" and "L".Additional price for configuration K L

Complete Relay with test switch installed and wired for CombiFlex rack mounting.

Note! Not available for standard configuration "G" and "L".Additional price for configuration N L

Standard

IEC B

Main Application

Feeder protection and control F

Standard Configuration (descriptions in short)

A = Non-directional O/C and directional E/F protection. A

B = Non-directional O/C, directional E/F and CB condition monitoring (RTD option) B

C = Non-directional O/C and non-directional E/F protection C

D = Non-directional O/C, non-directional E/F and CB condition monitoring

(RTD option)D

E = Non-directional O/C, directional E/F, voltage based measurements and CB

condition monitoring (RTD option)E

F = Directional O/C, directional E/F, voltage based protections & measurements

and CB condition monitoring (RTD option)F

G = Directional O/C and directional E/F protection, phase-voltage based protection

and measurement functions, CB condition monitoring, (sensor inputs).G

H = Non-directional O/C, Non-directional E/F, voltage & frequency based protection

& measurements, synchro-check and CB condition monitoring (RTD option)H

J = Directional O/C, directional E/F, voltage & frequency based protection &

measurements, synchro-check and CB condition monitoring (optional power

quality, RTD option)

J

K = Directional and non-directional O/C and E/F, high impedance restricted E/F,

voltage & frequency based protection & measurements, synchro-check and CB

condition monitoring (optional power quality and fault locator)

K

L = Directional O/C, directional E/F, voltage & frequency based protection &

measurements and CB condition monitoring (Sensor inputs, optional power

quality and fault locator)

L

N = Directional and non-directional O/C and E/F, voltage & frequency based

protection & measurements, synchro-check and CB condition monitoring

(optional power quality and fault locator)

N

Analog Inputs/Outputs

Std conf A: 4I + U0 (Io 1/5A) A AA

Std conf A: 4I + U0 (Io 0.2/1A) A AB

Std conf B: 4I + U0 (Io 1/5A) B AA

Std conf B: 4I + U0 (Io 0.2/1A) B AB

Std conf B: 4I + U0 (Io 1/5A) + 6RTD + 2mA B FA

Std conf B: 4I + U0 (Io 0.2/1A) + 6RTD + 2mA B FB

Std conf C: 4I (Io 1/5A) C AC

Std conf C: 4I (Io 0.2/1A) C AD

Std conf D: 4I (Io 1/5A) D AC

Std conf D: 4I (Io 0.2/1A) D AD

Std conf D: 4I (Io 1/5A) + 6RTD + 2mA D FC

Std conf F: 4I (Io 0.2/1A) + 6RTD + 2mA F FD

Std conf E: 4I (Io 1/5A) + 5U E AE

Std conf E: 4I (Io 0.2/1A) + 5U E AF

Std conf F: 4I (Io 1/5A) + 5U F AE

Std conf F: 4I (Io 0.2/1A) + 5U F AF

Page 15: ABBOfflineOrderNumberTool_Ver_15.41b_758059_ENg.xls

REF615Feeder Protection and Control

Selected Order No. B F X G

Instructions / Order No. Pos. 1 2 3 4 5/6 7/8 9 10 11 12 13 14 15 16 17 18 EUR

Std conf H: 4I (Io 1/5A) + 5U H AE

Std conf H: 4I (Io 0.2/1A) + 5U H AF

Std conf J: 4I (Io 1/5A) + 5U J AE

Std conf J: 4I (Io 0.2/1A) + 5U J AF

Std conf N: 4I (Io 1/5A) + 5U N AE

Std conf N: 4I (Io 0.2/1A) + 5U N AF

Std conf G: 3Is + 3Us + Io (Io 0.2/1A) G DA

Std conf L: 3Is + 3Us + Io (Io 0.2/1A) L DA

Std conf K: 7I (Io 1/5A) + 5U K BC

Std conf E: 4I (Io 1/5A) + 5U + 2RTD + 1mA E FE

Std conf E: 4I (Io 0.2/1A) + 5U + 2RTD + 1mA E FF

Std conf F: 4I (Io 1/5A) + 5U + 2RTD + 1mA F FE

Std conf F: 4I (Io 0.2/1A) + 5U + 2RTD + 1mA F FF

Std conf H: 4I (Io 1/5A) + 5U + 2RTD + 1mA H FE

Std conf H: 4I (Io 0.2/1A) + 5U + 2RTD + 1mA H FF

Std conf J: 4I (Io 1/5A) + 5U + 2RTD + 1mA J FE

Std conf J: 4I (Io 0.2/1A) + 5U + 2RTD + 1mA J FF

Std conf N: 4I (Io 1/5A) + 5U + 2RTD + 1mA N FE

Std conf N: 4I (Io 0.2/1A) + 5U + 2RTD + 1mA N FF

Binary Inputs/Outputs

3BI + 6BO Only for Standard Configuration A AA

4BI + 6BO Only for Standard Configuration C AB

11BI + 10BO Only for Standard Configuration B AC

11BI + 6BO + 3HSO Only for Standard Configuration B FG

12BI + 10BO Not for Standard Configurations A,B,C and G AD

12BI + 6BO + 3HSO Not for Standard Configurations A,B,C and G FE

17BI + 13BOOnly for Standard Configuration B

Note! Order No. 5/6 = AA or ABAE

17BI + 9BO + 3HSOOnly for Standard Configuration B

Note! Order No. 5/6 = AA or ABFA

18BI + 13BOOnly for Standard Configuration D

Note! Order No. 5/6 = AC or ADAF

18BI + 9BO + 3HSOOnly for Standard Configuration D

Note! Order No. 5/6 = AC or ADFB

16BI + 10BOOnly for Standard Configurations E,F,H,J and N

Note! Order No. 5/6 = AE or AFAG

16BI + 6BO + 3HSOOnly for Standard Configurations E,F,H,J and N

Note! Order No. 5/6 = AE or AFFC

8BI + 10BO Only for Standard Configurations G and L AH

8BI + 6BO + 3HSO Only for Standard Configurations G and L FD

Communication (Serial/Ethernet)

RS 485 (including IRIG-B) + Ethernet 100Base FX (LC) A A

RS 485 (including IRIG-B) + Ethernet 100Base TX (RJ45) A B

RS 485 (including IRIG-B) A N

Glassfibre ST + Ethernet 100Base TX (RJ45) B B

Glassfibre ST + Ethernet 100Base FX (1xLC, 2xRJ45) with HSR/PRP B C

Glassfibre ST + Ethernet 100Base TX (3xRJ45) with HSR/PRP B D

Glassfibre ST + Ethernet 100Base FX (2xLC, 1xRJ45) with HSR/PRP B E

Glassfibre ST + Ethernet 100Base FX (1xLC, 2xRJ45) with HSR/PRP and

IEC61850-9-2LE

Not available for Standard Configuration

A,B,C and DB F

Glassfibre ST + Ethernet 100Base TX (3xRJ45) with HSR/PRP and

IEC61850-9-2LE

Not available for Standard Configuration

A,B,C and DB G

Glassfibre ST + Ethernet 100Base FX (2xLC, 1xRJ45) with HSR/PRP and

IEC61850-9-2LE

Not available for Standard Configuration

A,B,C and DB H

Glassfibre ST B N

RS 232/485 (including IRIG-B) + Ethernet 100Base TX (RJ45) C B

RS 232/485 + RS485 / Glassfibre ST (including IRIG-B) C N

Ethernet 100Base FX (LC) N A

Ethernet 100Base TX (RJ45) N B

Ethernet 100Base FX (1xLC, 2xRJ45) with HSR/PRP N C

Ethernet 100Base TX (3xRJ45) with HSR/PRP N D

Ethernet 100Base FX (2xLC, 1xRJ45) with HSR/PRP N E

Ethernet 100Base FX (1xLC, 2xRJ45) with HSR/PRP and IEC61850-9-2LENot available for Standard Configuration

A,B,C and DN F

Ethernet 100Base TX (3xRJ45) with HSR/PRP and IEC61850-9-2LENot available for Standard Configuration

A,B,C and DN G

Ethernet 100Base FX (2xLC, 1xRJ45) with HSR/PRP and IEC61850-9-2LENot available for Standard Configuration

A,B,C and DN H

None N N

Communication (Protocol)

IEC 61850 Only when Order No. 9 = N A

Page 16: ABBOfflineOrderNumberTool_Ver_15.41b_758059_ENg.xls

REF615Feeder Protection and Control

Selected Order No. B F X G

Instructions / Order No. Pos. 1 2 3 4 5/6 7/8 9 10 11 12 13 14 15 16 17 18 EUR

Modbus B

IEC 61850+Modbus C

IEC 103 D

DNP 3.0 E

IEC 61850 + IEC103 G

IEC 61850 + DNP 3.0 H

Language

English 1

English and German 3

English and Swedish 4

English and Spanish 5

English and Russian 6

English and French C

English and Czech E

Front Panel

Small LCD A

Large LCD with Single Line Diagram B

Option 1

Reclosing A

Arc ProtectionNOT allowed when Order No.

9/10 = BB,BN,CB,CN or NNB

Arc Protection and ReclosingNOT allowed when Order No.

9/10 = BB,BN,CB,CN or NNC

Power QualityOnly for Standard Configuration

J,K,L and ND

Power Quality and ReclosingOnly for Standard Configuration

J,K,L and NE

Power Quality and Arc Protection

Only for Standard Configuration J,K,L and N

NOT allowed when Order No.

9/10 = BB,BN,CB,CN or NN

F

Power Quality and Arc Protection and ReclosingOnly for Standard Configuration J,K,L and N

NOT allowed when Order No.

9/10 = BB,BN,CB,CN or NN

G

Fault locator and Reclosing Only for Standard Configuration K,N and L H

Fault locator and Arc ProtectionOnly for Standard Configuration K,N and L

NOT allowed when Order No.

9/10 = BB,BN,CB,CN or NN

J

Fault locator and Arc Protection and ReclosingOnly for Standard Configuration K,N and L

NOT allowed when Order No.

9/10 = BB,BN,CB,CN or NN

K

Fault locator and Power Quality Only for Standard Configuration K,N and L L

Fault locator and Power Quality and Reclosing Only for Standard Configuration K,N and L M

Fault locator and Power Quality and Arc Protection

Only for Standard Configuration K,N and L

NOT allowed when Order No.

9/10 = BB,BN,CB,CN or NN

P

Fault locator and Power Quality and Arc Protection and ReclosingOnly for Standard Configuration K,N and L

NOT allowed when Order No.

9/10 = BB,BN,CB,CN or NN

Q

None N

Option 2

Directional E/FOnly for Standard Configuration

A,B,E,F,G,J,L and NA

Admittance based E/F + Directional E/FOnly for Standard Configuration

A,B,E,F,G,J,L and NB

Wattmetric based E/F + Directional E/FOnly for Standard Configuration

A,B,E,F,G,J,L and NC

Harmonics based E/F + Directional E/F Only for Standard Configuration B,F,J,L and N D

Harmonics based E/F Only for Standard Configuration D E

None Only for Standard Configuration C,D,H and K N

Power Supply

48-250 Vdc; 100-240 Vac 1

24-60 Vdc 2

Version

Product Version 5.0 X G

Mounting accessories and arc sensors for REF615

Description Order No.

Semi-flush mounting kit 1MRS050696

Wall mounting kit 1MRS050697

Inclined semi-flush mounting kit 1MRS050831

19” rack mounting kit with cut-out for one IED 1MRS050694

Price

EUR

0

0

0

0

Page 17: ABBOfflineOrderNumberTool_Ver_15.41b_758059_ENg.xls

REF615Feeder Protection and Control

Selected Order No. B F X G

Instructions / Order No. Pos. 1 2 3 4 5/6 7/8 9 10 11 12 13 14 15 16 17 18 EUR

19” rack mounting kit with cut-out for two IEDs 1MRS050695

Mounting bracket for one IED with test switch RTXP in 4U Combiflex

(RHGT 19” variant C)2RCA022642P0001

Mounting bracket for one IED in 4U Combiflex (RHGT 19” variant C) 2RCA022643P0001

19” rack mounting kit for one IED and one RTXP18 test switch (the

test switch is not included in the delivery)2RCA021952A0003

19” rack mounting kit for one IED and one RTXP24 test switch (the

test switch is not included in the delivery)2RCA022561A0003

Cable for optical sensors for arc protection 1.5 m 1MRS120534-1.5

Cable for optical sensors for arc protection 3.0 m 1MRS120534-3

Cable for optical sensors for arc protection 5.0 m 1MRS120534-5

0

0

0

0

0

0

0

0

Page 18: ABBOfflineOrderNumberTool_Ver_15.41b_758059_ENg.xls

REM615Motor Protection and Control

Selected Order No. B M N X G

Instructions / Order No. Pos. 1 2 3 4 5/6 7/8 9 10 11 12 13 14 15 16 17 18 EUR

IED

Complete Relay H

Complete Relay with test switch installed and wired in 19'' cover plate

Note! Not available for standard configuration "D".Additional price for configuration A K

Complete Relay with test switch installed and wired in 19'' cover plate

Note! Not available for standard configuration "D"Additional price for configuration B K

Complete Relay with test switch installed and wired in 19'' cover plate

Note! Not available for standard configuration "D"Additional price for configuration C K

Complete Relay with test switch installed and wired for CombiFlex rack mounting

Note! Not available for standard configuration "D"Additional price for configuration A L

Complete Relay with test switch installed and wired for CombiFlex rack mounting

Note! Not available for standard configuration "D"Additional price for configuration B L

Complete Relay with test switch installed and wired for CombiFlex rack mounting

Note! Not available for standard configuration "D"Additional price for configuration C L

Standard

IEC B

Main Application

Motor protection and control M

Standard configuration (descriptions in short)

A = Motor protection, optional RTD/mA inputs A

B = Motor protection with current, voltage and frequency based

protection and measurement functions, optional RTD/mA inputsB

C = Motor protection with current and voltage based protection

and measurement functionsC

D = Motor protection with voltage & frequency based protection and measurements

(Sensor inputs)D

Analog Inputs/Outputs

Std conf A: 4I (Io 1/5A) A AC

Std conf A: 4I (Io 0.2/1A) A AD

Std conf C: 4I (Io 1/5A) + 5U C AE

Std conf C: 4I (Io 0.2/1A) + 5U C AF

Std conf A: 4I (Io 1/5A) + 2mA + 6RTD A AG

Std conf A: 4I (Io 0.2/1A) + 2mA + 6RTD A AH

Std conf B: 4I + 3U (Io 1/5A) B CA

Std conf B: 4I + 3U (Io 0.2/1A) B CB

Std conf B: 4I (Io 1/5A) + 3U + 2mA + 6RTD B CC

Std conf B: 4I (Io 0.2/1A) + 3U + 2mA + 6RTD B CD

Std conf D: 3Is + 3Us + Io (Io 0.2/1A) D DA

Binary Inputs/Outputs

4BI+6BO Only for Standard Configuration A AB

12BI+10BO Only for Standard Configuration A AD

12BI+6BO+3HSO Only for Standard Configuration A FE

16BI+10BO Only for Standard Configuration C AG

16BI+6BO+3HSO Only for Standard Configuration C FC

8BI+10BO Only for Standard Configuration B and D AH

14BI + 13BOOnly for Standard Configuration B

Note! Order No. 5/6 must be CA or CBAJ

8BI+6BO+3HSO Only for Standard Configuration B and D FD

14BI+9BO+3HSOOnly for Standard Configuration B

Note! Order No. 5/6 must be CA or CBFF

Communication (Serial/Ethernet)

RS 485 (including IRIG-B) + Ethernet 100Base FX (LC) A A

RS 485 (including IRIG-B) + Ethernet 100Base TX (RJ45) A B

RS 485 (including IRIG-B) A N

Glassfibre ST + Ethernet 100Base TX (RJ45) B B

Glassfibre ST + Ethernet 100Base FX (1xLC, 2xRJ45) with HSR/PRP B C

Glassfibre ST + Ethernet 100Base TX (3xRJ45) with HSR/PRP B D

Glassfibre ST + Ethernet 100Base FX (2xLC, 1xRJ45) with HSR/PRP B E

Glassfibre ST + Ethernet 100Base FX (1xLC, 2xRJ45) with HSR/PRP and

IEC61850-9-2LENot available for Standard Configuration A B F

Glassfibre ST + Ethernet 100Base TX (3xRJ45) with HSR/PRP and

IEC61850-9-2LENot available for Standard Configuration A B G

Glassfibre ST + Ethernet 100Base FX (2xLC, 1xRJ45) with HSR/PRP and

IEC61850-9-2LENot available for Standard Configuration A B H

Glassfibre ST B N

RS 232/485 (including IRIG-B) + Ethernet 100Base TX (RJ45) C B

RS 232/485 + RS485 / Glassfibre ST (including IRIG-B) C N

Ethernet 100Base FX (LC) N A

Ethernet 100Base TX (RJ45) N B

Ethernet 100Base FX (1xLC, 2xRJ45) with HSR/PRP N C

Page 19: ABBOfflineOrderNumberTool_Ver_15.41b_758059_ENg.xls

REM615Motor Protection and Control

Selected Order No. B M N X G

Instructions / Order No. Pos. 1 2 3 4 5/6 7/8 9 10 11 12 13 14 15 16 17 18 EUR

Ethernet 100Base TX (3xRJ45) with HSR/PRP N D

Ethernet 100Base FX (2xLC, 1xRJ45) with HSR/PRP N E

Ethernet 100Base FX (1xLC, 2xRJ45) with HSR/PRP and IEC61850-9-2LE Not available for Standard Configuration A N F

Ethernet 100Base TX (3xRJ45) with HSR/PRP and IEC61850-9-2LE Not available for Standard Configuration A N G

Ethernet 100Base FX (2xLC, 1xRJ45) with HSR/PRP and IEC61850-9-2LE Not available for Standard Configuration A N H

None N N

Communication (Protocol)

IEC 61850 Only when Order No. 9 = N A

Modbus B

IEC 61850+Modbus C

IEC 103 D

DNP 3.0 E

IEC 61850 + IEC103 G

IEC 61850 + DNP 3.0 H

Language

English 1

English and German 3

English and Swedish 4

English and Spanish 5

English and Russian 6

English and French C

English and Czech E

Front Panel

Small LCD A

Large LCD with Single Line Diagram B

Option 1

Arc protectionNOT allowed when Order No.

9/10 = BB,BN,CB,CN or NNB

None N

Option 2

None N

Power Supply

48-250 Vdc; 100-240 Vac 1

24-60 Vdc 2

Version

Product Version 5.0 X G

Mounting accessories and arc sensors for REM615

Description Order No.

Semi-flush mounting kit 1MRS050696

Wall mounting kit 1MRS050697

Inclined semi-flush mounting kit 1MRS050831

19” rack mounting kit with cut-out for one IED 1MRS050694

19” rack mounting kit with cut-out for two IEDs 1MRS050695

Mounting bracket for one IED with test switch RTXP in 4U Combiflex

(RHGT 19” variant C)2RCA022642P0001

Mounting bracket for one IED in 4U Combiflex (RHGT 19” variant C) 2RCA022643P0001

19” rack mounting kit for one IED and one RTXP18 test switch (the

test switch is not included in the delivery)2RCA021952A0003

19” rack mounting kit for one IED and one RTXP24 test switch (the

test switch is not included in the delivery)2RCA022561A0003

Cable for optical sensors for arc protection 1.5 m 1MRS120534-1.5

Cable for optical sensors for arc protection 3.0 m 1MRS120534-3

Cable for optical sensors for arc protection 5.0 m 1MRS120534-5

0

0

Price

EUR

0

0

0

0

0

0

0

0

0

0

Page 20: ABBOfflineOrderNumberTool_Ver_15.41b_758059_ENg.xls

RET615Transformer Protection and Control

Selected Order No. B T N X G

Instructions / Order No. Pos. 1 2 3 4 5/6 7/8 9 10 11 12 13 14 15 16 17 18 EUR

IED

615 series IED (including case) H

Complete Relay with test switch installed and wired in 19'' cover plate

Note! Not available for standard configuration "D".Additional price for configuration A,B,C,D K

Complete Relay with test switch installed and wired in 19'' cover plate

Note! Not available for standard configuration "D".Additional price for configuration E,F,G,H K

Complete Relay with test switch installed and wired for CombiFlex rack mounting

Note! Not available for standard configuration "D"Additional price for configuration A,B,C,D L

Complete Relay with test switch installed and wired for CombiFlex rack mounting

Note! Not available for standard configuration "D"Additional price for configuration E,F,G,H L

Standard

IEC B

Main Application

Transformer protection and control T

Standard Configuration (descriptions in short)

A = Transformer differential protection, numerical restricted

E/F protection for the HV side, optional RTD/mA inputsA

B = Transformer differential protection, numerical restricted

E/F protection for the LV side, optional RTD/mA inputsB

C = Transformer differential protection, high-impedance based restricted

E/F protection for the HV side, optional RTD/mA inputsC

D = Transformer differential protection, high-impedance based restricted

E/F protection for the LV side, optional RTD/mA inputsD

E = Transformer differential protection, numerical restricted

E/F protection for the high-voltage HV side, phase-voltage

based prot. and measurement functions

E

F = Transformer differential protection, numerical restricted

E/F protection for the LV side, phase-voltage based protection

and measurement functions

F

G = Transformer differential protection, high-impedance based restricted

E/F protection for the HV side, phase-voltage based protection and

measurement functions

G

H = Transformer differential protection, high-impedance based restricted

E/F protection for the LV side, phase-voltage based protection and

measurement functions

H

Analog Inputs/Outputs

Std conf A: 7I (Io 1/5A) A BA

Std conf A: 7I (Io 1/5A) + 6RTD + 2mA A BG

Std conf B: 7I (Io 1/5A) B BA

Std conf B: 7I (Io 1/5A) + 6RTD + 2mA B BG

Std conf C: 7I (Io 1/5A) C BA

Std conf C: 7I (Io 1/5A) + 6RTD + 2mA C BG

Std conf D: 7I (Io 1/5A) D BA

Std conf D: 7I (Io 1/5A) + 6RTD + 2mA D BG

Std conf E: 7I (Io 1/5A) + 5U E BC

Std conf E: 7I (Io 1/5A) + 5U + 2RTD + 1mA E BE

Std conf F: 7I (Io 1/5A) + 5U F BC

Std conf F: 7I (Io 1/5A) + 5U + 2RTD + 1mA F BE

Std conf G: 7I (Io 1/5A) + 5U G BC

Std conf G: 7I (Io 1/5A) + 5U + 2RTD + 1mA G BE

Std conf H: 7I (Io 1/5A) + 5U H BC

Std conf H: 7I (Io 1/5A) + 5U + 2RTD + 1mA H BE

Binary Inputs/Outputs

8BI+ 10BOOnly for Standard Configuration A,B,C,D.

For E,F,G,H when Order No. 5/6 = BEBA

14BI + 13BOOnly for Standard Configuration A,B,C,D.

Note! Order No. 5/6 = BABB

8BI+6BO+3HSOOnly for Standard Configuration A,B,C,D.

For E,F,G,H when Order No. 5/6 = BEFD

14BI+9BO+3HSOOnly for Standard Configuration A,B,C,D.

Note! Order No. 5/6 = BAFF

12BI + 10BOOnly for Standard Configuration E,F,G,H.

Note! Order No. 5/6 = BCAD

12BI+6BO+3HSOOnly for Standard Configuration E,F,G,H.

Note! Order No. 5/6 = BCFE

Communication (Serial/Ethernet)

RS 485 (including IRIG-B) + Ethernet 100Base FX (LC) A A

RS 485 (including IRIG-B) + Ethernet 100Base TX (RJ45) A B

RS 485 (including IRIG-B) A N

Glassfibre ST + Ethernet 100Base TX (RJ45) B B

Glassfibre ST + Ethernet 100Base FX (1xLC, 2xRJ45) with HSR/PRP B C

Glassfibre ST + Ethernet 100Base TX (3xRJ45) with HSR/PRP B D

Glassfibre ST + Ethernet 100Base FX (2xLC, 1xRJ45) with HSR/PRP B E

Page 21: ABBOfflineOrderNumberTool_Ver_15.41b_758059_ENg.xls

RET615Transformer Protection and Control

Selected Order No. B T N X G

Instructions / Order No. Pos. 1 2 3 4 5/6 7/8 9 10 11 12 13 14 15 16 17 18 EUR

Glassfibre ST + Ethernet 100Base FX (1xLC, 2xRJ45) with HSR/PRP and

IEC61850-9-2LE

Not available for Standard Configuration

A,B,C and DB F

Glassfibre ST + Ethernet 100Base TX (3xRJ45) with HSR/PRP and

IEC61850-9-2LE

Not available for Standard Configuration

A,B,C and DB G

Glassfibre ST + Ethernet 100Base FX (2xLC, 1xRJ45) with HSR/PRP and

IEC61850-9-2LE

Not available for Standard Configuration

A,B,C and DB H

Glassfibre ST B N

RS 232/485 (including IRIG-B) + Ethernet 100Base TX (RJ45) C B

RS 232/485 + RS485 / Glassfibre ST (including IRIG-B) C N

Ethernet 100Base FX (LC) N A

Ethernet 100Base TX (RJ45) N B

Ethernet 100Base FX (1xLC, 2xRJ45) with HSR/PRP N C

Ethernet 100Base TX (3xRJ45) with HSR/PRP N D

Ethernet 100Base FX (2xLC, 1xRJ45) with HSR/PRP N E

Ethernet 100Base FX (1xLC, 2xRJ45) with HSR/PRP and IEC61850-9-2LENot available for Standard Configuration

A,B,C and DN F

Ethernet 100Base TX (3xRJ45) with HSR/PRP and IEC61850-9-2LENot available for Standard Configuration

A,B,C and DN G

Ethernet 100Base FX (2xLC, 1xRJ45) with HSR/PRP and IEC61850-9-2LENot available for Standard Configuration

A,B,C and DN H

None N N

Communication (Protocol)

IEC 61850 Only when Order No. 9 = N A

Modbus B

IEC 61850+Modbus C

IEC 103 D

DNP 3.0 E

IEC 61850 + IEC103 G

IEC 61850 + DNP 3.0 H

Language

English 1

English and German 3

English and Swedish 4

English and Spanish 5

English and Russian 6

English and French C

English and Czech E

Front Panel

Small LCD A

Large LCD with Single Line Diagram B

Option 1

Arc protectionNOT allowed when Order No.

9/10 = BB,BN,CB,CN or NNB

None N

Option 2

None N

Power Supply

48-250 Vdc; 100-240 Vac 1

24-60 Vdc 2

Version

Product Version 5.0 X G

Mounting accessories and arc sensors for RET615

Description Order No.

Semi-flush mounting kit 1MRS050696

Wall mounting kit 1MRS050697

Inclined semi-flush mounting kit 1MRS050831

19” rack mounting kit with cut-out for one IED 1MRS050694

19” rack mounting kit with cut-out for two IEDs 1MRS050695

Mounting bracket for one IED with test switch RTXP in 4U Combiflex

(RHGT 19” variant C)2RCA022642P0001

Mounting bracket for one IED in 4U Combiflex (RHGT 19” variant C) 2RCA022643P0001

19” rack mounting kit for one IED and one RTXP18 test switch (the

test switch is not included in the delivery)2RCA021952A0003

19” rack mounting kit for one IED and one RTXP24 test switch (the

test switch is not included in the delivery)2RCA022561A0003

Price

EUR

0

0

0

0

0

0

0

0

0

Page 22: ABBOfflineOrderNumberTool_Ver_15.41b_758059_ENg.xls

RET615Transformer Protection and Control

Selected Order No. B T N X G

Instructions / Order No. Pos. 1 2 3 4 5/6 7/8 9 10 11 12 13 14 15 16 17 18 EUR

Cable for optical sensors for arc protection 1.5 m 1MRS120534-1.5

Cable for optical sensors for arc protection 3.0 m 1MRS120534-3

Cable for optical sensors for arc protection 5.0 m 1MRS120534-5 0

0

0

Page 23: ABBOfflineOrderNumberTool_Ver_15.41b_758059_ENg.xls

RED615Line Differential Protection and Control

Selected Order No. B D X G

Instructions / Order No. Pos. 1 2 3 4 5/6 7/8 9 10 11 12 13 14 15 16 17 18 EUR

IED

615 series IED (including case) H

Complete Relay with test switch installed and wired in 19'' cover plate.

Note! Not available for standard configuration "E".Additional price for configuration A and C K

Complete Relay with test switch installed and wired in 19'' cover plate.

Note! Not available for standard configuration "E".Additional price for configuration B K

Complete Relay with test switch installed and wired in 19'' cover plate.

Note! Not available for standard configuration "E".Additional price for configuration D K

Complete Relay with test switch installed and wired for CombiFlex rack mounting.

Note! Not available for standard configuration "E".Additional price for configuration A and C L

Complete Relay with test switch installed and wired for CombiFlex rack mounting.

Note! Not available for standard configuration "E".Additional price for configuration B L

Complete Relay with test switch installed and wired for CombiFlex rack mounting.

Note! Not available for standard configuration "E".Additional price for configuration D L

Standard

IEC B

Main Application

Line differential protection D

Standard Configuration (descriptions in short)

A = Line Differential Protection (LDP) A

B = LDP with directional E/F B

C = LDP with non-dir. E/F C

D = LDP with dir. O/C, dir. E/F, voltage and frequency protection (RTD option) D

E = LDP with dir. O/C, dir. E/F, voltage and frequency protection (Sensor inputs) E

Analog Inputs/Outputs

Std conf B: 4I + U0 (Io 1/5A) B AA

Std conf B: 4I + U0 (Io 0.2/1A) B AB

Std conf A: 4I (Io 1/5A) A AC

Std conf C: 4I (Io 1/5A) C AC

Std conf D: 4I (Io 1/5A) + 5U D AE

Std conf D: 4I (Io 0.2/1A) + 5U D AF

Std conf D: 4I (Io 1/5A) + 5U + 2RTD + 1mA D FE

Std conf D: 4I (Io 0.2/1A) + 5U + 2RTD + 1mA D FF

Std conf E: 3Is + 3Us + Io (Io 0.2/1A) E DA

Binary Inputs/Outputs

11BI+10BO AC

12BI+10BO AD

17BI+13BO AE

18BI+13BO AF

16BI + 10BO AG

8BI + 10BO AH

Communication (Serial/Ethernet)

RS 485 (connector incl. IRIG-B) + Line differential, multi mode fiber (LC) A A

RS 485 (connector incl. IRIG-B) + Line differential, single mode fiber (LC) A B

RS 485 (connector incl. IRIG-B) + Ethernet 100Base TX (RJ45) and line differential, multi mode fiber (LC) A G

RS 485 (connector incl. IRIG-B) + Ethernet 100Base TX (RJ45) and line differential,

single mode fiber (LC)A H

RS 485 (connector incl. IRIG-B) + 2 x Ethernet 100Base TX (RJ45) and line differential,

multi mode fiber (LC)A J

RS 485 (connector incl. IRIG-B) + 2 x Ethernet 100Base TX (RJ45) and line differential, single mode fiber (LC) A K

ST glass fibre (Rx/Tx) + Line differential, multi mode fiber (LC) B A

ST glass fibre (Rx/Tx) + Line differential, single mode fiber (LC) B B

ST glass fibre (Rx/Tx) + Ethernet 100Base TX (RJ45) and line differential, multi mode fiber (LC) B G

ST glass fibre (Rx/Tx) + Ethernet 100Base TX (RJ45) and line differential, single mode

fiber (LC)B H

ST glass fibre (Rx/Tx) + 2 x Ethernet 100Base TX (RJ45) and line differential, multi mode

fiber (LC)B J

ST glass fibre (Rx/Tx) + 2 x Ethernet 100Base TX (RJ45) and line differential, single mode fiber (LC) B K

Line differential, multi mode fiber (LC) N A

Line differential, single mode fiber (LC) N B

Ethernet 100Base TX (RJ45) and line differential, multi mode fiber (LC) N G

Ethernet 100Base TX (RJ45) and line differential, single mode fiber (LC) N H

2 x Ethernet 100Base TX (RJ45) and line differential, multi mode fiber (LC) N J

2 x Ethernet 100Base TX (RJ45) and line differential, single mode fiber (LC) N K

Communication (Protocol)

IEC 61850 A

Modbus B

Page 24: ABBOfflineOrderNumberTool_Ver_15.41b_758059_ENg.xls

RED615Line Differential Protection and Control

Selected Order No. B D X G

Instructions / Order No. Pos. 1 2 3 4 5/6 7/8 9 10 11 12 13 14 15 16 17 18 EUR

IEC 61850+Modbus C

IEC 103 D

DNP 3.0 E

IEC 61850 + IEC103 G

IEC 61850 + DNP 3.0 H

Language

English 1

English and German 3

English and Swedish 4

English and Spanish 5

English and Russian 6

English and French C

English and Czech E

Front Panel

Small LCD A

Large LCD with Single Line Diagram B

Option 1

Reclosing Only for Stand.Conf. B,C,D and E A

Power Quality Only for Stand.Conf. D and E D

Power Quality and Reclosing Only for Stand.Conf. D and E E

Fault locator and Reclosing Only for Stand.Conf. D and E H

Fault locator and Power Quality Only for Stand.Conf. D and E L

Fault locator and Power Quality and Reclosing Only for Stand.Conf. D and E M

None Only for Stand.Conf. D and E N

Option 2

Directional E/F Only for Stand.Conf. B,D and E A

Admittance based E/F + Directional E/F Only for Stand.Conf. B,D and E B

Wattmetric based E/F + Directional E/F Only for Stand.Conf. B,D and E C

Harmonics based E/F + Directional E/F Only for Stand.Conf. B,D and E D

Harmonics based E/F Only for Stand.Conf. C E

None Only for Stand.Conf. A and C N

Power Supply

48...250 V DC, 100...240 V AC 1

24…60 V DC 2

Version

Version 5.0 X G

Pilot wire communication

Description Order No.

Pilot Wire communication package including two Pilot Wire modems:

RPW600AM (master) and RPW600AF (follower)RPW600AMF

Diagnostics kit including the RPW-diagnostic tool, a diagnostic cable

and a CD with necessary drivers and informationRPW600ADP

3.0 meter LC-LC single-mode fibre-optic patch cable for connecting

one Pilot Wire modem to the RED615 IED

Please note that two patch cables are required for connecting the

Pilot Wire communication package (RPW600AMF).

1MRS120547-3

Mounting accessories for RED615

Description Order No.

Semi-flush mounting kit 1MRS050696

Wall mounting kit 1MRS050697

Inclined semi-flush mounting kit 1MRS050831

19” rack mounting kit with cut-out for one IED 1MRS050694

19” rack mounting kit with cut-out for two IEDs 1MRS050695

Mounting bracket for one IED with test switch RTXP in 4U Combiflex

(RHGT 19” variant C)2RCA022642P0001

Mounting bracket for one IED in 4U Combiflex (RHGT 19” variant C) 2RCA022643P0001

19” rack mounting kit for one IED and one RTXP18 test switch (the

test switch is not included in the delivery)2RCA021952A0003

19” rack mounting kit for one IED and one RTXP24 test switch (the

test switch is not included in the delivery)2RCA022561A0003

Price

EUR

0

0

Price

EUR

0

0

0

0

0

0

0

0

0

0

Page 25: ABBOfflineOrderNumberTool_Ver_15.41b_758059_ENg.xls

REU615Voltage Protection and Control

Selected Order No. B U N X G

Instructions / Order No. Pos. 1 2 3 4 5/6 7/8 9 10 11 12 13 14 15 16 17 18 EUR

IED

615 series IED (including case) H

Complete Relay with test switch installed and wired in 19'' cover plate. Additional price for configuration A K

Complete Relay with test switch installed and wired in 19'' cover plate. Additional price for configuration B K

Complete Relay with test switch installed and wired for CombiFlex rack mounting. Additional price for configuration A L

Complete Relay with test switch installed and wired for CombiFlex rack mounting. Additional price for configuration B L

Standard

IEC B

Main Application

Voltage protection and control U

Standard Configuration (descriptions in short)

A = Voltage and frequency based protection and measurement

functions, synchro-check and load sheddingA

B = Automatic voltage regulator B

Analog Inputs/Outputs

Std conf B: 4I + 3U (Io 1/5A) B CA

Std conf B: 4I (Io 1/5A) + 3U + 2mA + 6RTD B CC

Std conf A: 5U A EA

Binary I/O

12BI + 10BO Only for Standard Configuration A AD

12BI + 6BO + 3HSO Only for Standard Configuration A FE

8BI + 10BO Only for Standard Configuration B AH

14BI + 13BOOnly for Standard Configuration B

Note! Order No. 5/6 = CABB

Communication (Serial/Ethernet)

RS 485 (including IRIG-B) + Ethernet 100Base FX (LC) A A

RS 485 (including IRIG-B) + Ethernet 100Base TX (RJ45) A B

RS 485 (including IRIG-B) A N

Glassfibre ST + Ethernet 100Base TX (RJ45) B B

Glassfibre ST + Ethernet 100Base FX (1xLC, 2xRJ45) with HSR/PRP B C

Glassfibre ST + Ethernet 100Base TX (3xRJ45) with HSR/PRP B D

Glassfibre ST + Ethernet 100Base FX (2xLC, 1xRJ45) with HSR/PRP B E

Glassfibre ST + Ethernet 100Base FX (1xLC, 2xRJ45) with HSR/PRP and

IEC61850-9-2LEB F

Glassfibre ST + Ethernet 100Base TX (3xRJ45) with HSR/PRP and

IEC61850-9-2LEB G

Glassfibre ST + Ethernet 100Base FX (2xLC, 1xRJ45) with HSR/PRP and

IEC61850-9-2LEB H

Glassfibre ST B N

RS 232/485 (including IRIG-B) + Ethernet 100Base TX (RJ45) C B

RS 232/485 + RS485 / Glassfibre ST (including IRIG-B) C N

Ethernet 100Base FX (LC) N A

Ethernet 100Base TX (RJ45) N B

Ethernet 100Base FX (1xLC, 2xRJ45) with HSR/PRP N C

Ethernet 100Base TX (3xRJ45) with HSR/PRP N D

Ethernet 100Base FX (2xLC, 1xRJ45) with HSR/PRP N E

Ethernet 100Base FX (1xLC, 2xRJ45) with HSR/PRP and IEC61850-9-2LE N F

Ethernet 100Base TX (3xRJ45) with HSR/PRP and IEC61850-9-2LE N G

Ethernet 100Base FX (2xLC, 1xRJ45) with HSR/PRP and IEC61850-9-2LE N H

None N N

Communication (Protocol)

IEC 61850 Only when Order No. 9 = N A

Modbus B

IEC 61850+Modbus C

IEC 103 D

DNP 3.0 E

IEC 61850 + IEC103 G

IEC 61850 + DNP 3.0 H

Language

English 1

English and German 3

English and Swedish 4

English and Spanish 5

Page 26: ABBOfflineOrderNumberTool_Ver_15.41b_758059_ENg.xls

REU615Voltage Protection and Control

Selected Order No. B U N X G

Instructions / Order No. Pos. 1 2 3 4 5/6 7/8 9 10 11 12 13 14 15 16 17 18 EUR

English and Russian 6

English and French C

English and Czech E

Front Panel

Small LCD A

Large LCD with Single Line Diagram B

Option 1

Arc protection

Only for Standard Configuration A

NOT allowed when Order No.

9/10 = BB,BN,CB,CN or NN

B

None N

Option 2

None N

Power Supply

48-250 Vdc; 100-240 Vac 1

24-60 Vdc 2

Version

Product Version 5.0 X G

Mounting accessories and arc sensors for REU615

Description Order No.

Semi-flush mounting kit 1MRS050696

Wall mounting kit 1MRS050697

Inclined semi-flush mounting kit 1MRS050831

19” rack mounting kit with cut-out for one IED 1MRS050694

19” rack mounting kit with cut-out for two IEDs 1MRS050695

Mounting bracket for one IED with test switch RTXP in 4U Combiflex

(RHGT 19” variant C)2RCA022642P0001

Mounting bracket for one IED in 4U Combiflex (RHGT 19” variant C) 2RCA022643P0001

19” rack mounting kit for one IED and one RTXP18 test switch (the

test switch is not included in the delivery)2RCA021952A0003

19” rack mounting kit for one IED and one RTXP24 test switch (the

test switch is not included in the delivery)2RCA022561A0003

Cable for optical sensors for arc protection 1.5 m 1MRS120534-1.5

Cable for optical sensors for arc protection 3.0 m 1MRS120534-3

Cable for optical sensors for arc protection 5.0 m 1MRS120534-5

Price

EUR

0

0

0

0

0

0

0

0

0

0

0

0

Page 27: ABBOfflineOrderNumberTool_Ver_15.41b_758059_ENg.xls

REV615Capacitor Bank Protection and Control

Selected Order No. B V N X G

Instructions / Order No. Pos. 1 2 3 4 5/6 7/8 9 10 11 12 13 14 15 16 17 18 EUR

IED

615 series IED (including case) H

Complete Relay with test switch installed and wired in 19'' cover plate. Additional price for configuration A K

Complete Relay with test switch installed and wired in 19'' cover plate. Additional price for configuration B K

Complete Relay with test switch installed and wired for CombiFlex rack mounting. Additional price for configuration A L

Complete Relay with test switch installed and wired for CombiFlex rack mounting. Additional price for configuration B L

Standard

IEC B

Main Application

Capacitor bank protection and control V

Standard Configuration (descriptions in short)

A = Capacitor bank overload and unbalance protection, Non-dir. O/C and

E/F and CB condition monitoringA

B = Capacitor bank overload and unbalance protection, Non-dir. O/C and dir. E/F,

voltage & frequency based protection & measurements and CB condition

monitoring

B

Analog Inputs/Outputs

Std conf A: 7I (Io 1/5A) A BA

Std conf B: 7I (Io 1/5A) + 5U B BC

Std conf A: 7I (Io 1/5A) + 6RTD + 2mA A BG

Std conf B: 7I (Io 1/5A) + 5U + 2RTD + 1mA B BE

Binary Inputs/Outputs

8BI+ 10BO Not allowed when Order No. 5/6 = BC BA

14BI + 13BO Only for Stand.Conf A when Order No. 5/6 = BA BB

8BI+6BO+3HSO Not allowed when Order No. 5/6 = BC FD

14BI+9BO+3HSO Only for Stand.Conf A when Order No. 5/6 = BA FF

12BI + 10BO Only when Order No. 5/6 = BC AD

12BI+6BO+3HSO Only when Order No. 5/6 = BC FE

Communication (Serial/Ethernet)

RS 485 (including IRIG-B) + Ethernet 100Base FX (LC) A A

RS 485 (including IRIG-B) + Ethernet 100Base TX (RJ45) A B

RS 485 (including IRIG-B) A N

Glassfibre ST + Ethernet 100Base TX (RJ45) B B

Glassfibre ST + Ethernet 100Base FX (1xLC, 2xRJ45) with HSR/PRP B C

Glassfibre ST + Ethernet 100Base TX (3xRJ45) with HSR/PRP B D

Glassfibre ST + Ethernet 100Base FX (2xLC, 1xRJ45) with HSR/PRP B E

Glassfibre ST + Ethernet 100Base FX (1xLC, 2xRJ45) with HSR/PRP and

IEC61850-9-2LENot available for Standard Configuration A B F

Glassfibre ST + Ethernet 100Base TX (3xRJ45) with HSR/PRP and

IEC61850-9-2LENot available for Standard Configuration A B G

Glassfibre ST + Ethernet 100Base FX (2xLC, 1xRJ45) with HSR/PRP and

IEC61850-9-2LENot available for Standard Configuration A B H

Glassfibre ST B N

RS 232/485 (including IRIG-B) + Ethernet 100Base TX (RJ45) C B

RS 232/485 + RS485 / Glassfibre ST (including IRIG-B) C N

Ethernet 100Base FX (LC) N A

Ethernet 100Base TX (RJ45) N B

Ethernet 100Base FX (1xLC, 2xRJ45) with HSR/PRP N C

Ethernet 100Base TX (3xRJ45) with HSR/PRP N D

Ethernet 100Base FX (2xLC, 1xRJ45) with HSR/PRP N E

Ethernet 100Base FX (1xLC, 2xRJ45) with HSR/PRP and IEC61850-9-2LE Not available for Standard Configuration A N F

Ethernet 100Base TX (3xRJ45) with HSR/PRP and IEC61850-9-2LE Not available for Standard Configuration A N G

Ethernet 100Base FX (2xLC, 1xRJ45) with HSR/PRP and IEC61850-9-2LE Not available for Standard Configuration A N H

None N N

Communication (Protocol)

IEC 61850 Only when Order No. 9 = N A

Modbus B

IEC 61850+Modbus C

IEC 103 D

DNP 3.0 E

IEC 61850 + IEC103 G

IEC 61850 + DNP 3.0 H

Language

English 1

English and German 3

Page 28: ABBOfflineOrderNumberTool_Ver_15.41b_758059_ENg.xls

REV615Capacitor Bank Protection and Control

Selected Order No. B V N X G

Instructions / Order No. Pos. 1 2 3 4 5/6 7/8 9 10 11 12 13 14 15 16 17 18 EUR

English and Swedish 4

English and Spanish 5

English and Russian 6

English and French C

English and Czech E

Front Panel

Small LCD A

Large LCD with Single Line Diagram B

Option 1

Arc ProtectionNOT allowed when Order No.

9/10 = BB,BN,CB,CN or NNB

Power Quality D

Power Quality and Arc ProtectionNOT allowed when Order No.

9/10 = BB,BN,CB,CN or NNF

None N

Option 2

None N

Power Supply

48-250 Vdc; 100-240 Vac 1

24-60 Vdc 2

Version

Product Version 5.0 X G

Mounting accessories and arc sensors for REV615

Description Order No.

Semi-flush mounting kit 1MRS050696

Wall mounting kit 1MRS050697

Inclined semi-flush mounting kit 1MRS050831

19” rack mounting kit with cut-out for one IED 1MRS050694

19” rack mounting kit with cut-out for two IEDs 1MRS050695

Mounting bracket for one IED with test switch RTXP in 4U Combiflex

(RHGT 19” variant C)2RCA022642P0001

Mounting bracket for one IED in 4U Combiflex (RHGT 19” variant C) 2RCA022643P0001

19” rack mounting kit for one IED and one RTXP18 test switch (the

test switch is not included in the delivery)2RCA021952A0003

19” rack mounting kit for one IED and one RTXP24 test switch (the

test switch is not included in the delivery)2RCA022561A0003

Cable for optical sensors for arc protection 1.5 m 1MRS120534-1.5

Cable for optical sensors for arc protection 3.0 m 1MRS120534-3

Cable for optical sensors for arc protection 5.0 m 1MRS120534-5

Price

EUR

0

0

0

0

0

0

0

0

0

0

0

0

Page 29: ABBOfflineOrderNumberTool_Ver_15.41b_758059_ENg.xls

RER615Recloser Protection and Control

Selected Order No. H B R 1 2 X F

Instructions / Order No. Pos. 1 2 3 4 5/6 7 8 9 10 11 12 13 14 15 16 17 18 EUR

IED

615 series IED (including case) H

Standard

IEC B

Main application

Recloser Protection and Control R

Standard configurations, analog and binary I/O options Standard configuration descriptions in short:

A = Sectionalizer/Midpoint recloser application to be used with conventional

transformers

- Phase voltage inputs based on conventional VT’s

- Phase current inputs based on conventional CT’s

- Residual current input based on conventional CT

D = Tie point recloser application with syncrocheck and voltage measurement

functions to be used with voltage sensors

- 6 pieces of phase voltage inputs based on voltage sensors

- Phase current inputs based on conventional CT’s

- Residual current input based on conventional CT

Std. conf. and I/O options

Std conf A: 4 CT (Io 0.2/1A) + 3 VT + 14 BI + 13 BO A AA A

Std conf A: 4 CT (Io 0.2/1A) + 3 VT + 8 BI + 10 BO A AA N

Std conf D: 4 CT (Io 0.2/1A) + 6 VD + 12 BI + 10 BO D AD N

Communication modules (Serial/Ethernet)

RS-232/485 + input for IRIG-B + Ethernet 100Base-TX (1 x RJ45) A B

Serial glass fibre (ST) + Ethernet 100Base-TX and -FX (1 x RJ-45 + 2 x LC) B E

RS-232/485 + RS-485 + input for IRIG-B

+ Ethernet 100Base-TX (1 x RJ-45)C B

Ethernet 100Base-FX (1 x LC) N A

Ethernet 100Base-TX (1 x RJ-45) N B

Ethernet 100Base-TX (3 x RJ-45) N D

Communication protocols

IEC 61850 A

IEC 61850 + IEC 60870-5-101 (slave) + IEC 60870-5-104 (slave) B

IEC 61850 + DNP3 TCP/IP (slave) + Modbus (slave) C

Language

English (IEC) + English (ANSI) 1

Front Panel

Small LCD with IEC symbols A

Large LCD with single line diagram (SLD) and IEC symbols B

Large LCD with single line diagram (SLD) and ANSI symbols F

Option 1

Directional earth-fault protection A

Directional overcurrent protection and directional earth-fault protection B

Admittance based earth-fault protection, directional overcurrent protection

and directional earth-fault protectionC

Wattmetric based earth-fault protection, directional overcurrent protection

and directional earth-fault protectionD

Harmonics based earth-fault protection, directional overcurrent protection

and directional earth-fault protectionE

None N

Option 2

Voltage and Frequency protection A

None N

Option 3

Power quality A

None N

Power supply

Page 30: ABBOfflineOrderNumberTool_Ver_15.41b_758059_ENg.xls

RER615Recloser Protection and Control

Selected Order No. H B R 1 2 X F

Instructions / Order No. Pos. 1 2 3 4 5/6 7 8 9 10 11 12 13 14 15 16 17 18 EUR

24-60 VDC 2

Version

Version 4.0 X F

Mounting accessories and arc sensors for RER615

Description Order No.

Semi-flush mounting kit 1MRS050696

Wall mounting kit 1MRS050697

Inclined semi-flush mounting kit 1MRS050831

19” rack mounting kit with cut-out for one IED 1MRS050694

19” rack mounting kit with cut-out for two IEDs 1MRS050695

0

0

0

0

Price

EUR

0

Page 31: ABBOfflineOrderNumberTool_Ver_15.41b_758059_ENg.xls

REC615Remote Monitoring and Control

Selected Order No. H B C 1 2 X F

Instructions / Order No. Pos. 1 2 3 4 5/6 7 8 9 10 11 12 13 14 15 16 17 18 EUR

IED

615 series IED (including case) H

Standard

IEC B

Main application

Remote Monitoring and Control C

Standard configurations, analog and binary I/O options Standard configuration descriptions in short:

A = Remote monitoring and control to be used with conventional transformers

- Phase voltage inputs based on conventional VT’s

- Phase current inputs based on conventional CT’s

- Residual current input based on conventional CT

B = Remote monitoring and control to be used with mixed transformers

- Phase voltage inputs based on voltage sensors

- Phase current inputs based on conventional CT’s

- Residual current input based on conventional CT

C = Remote monitoring and control to be used with sensors

- Phase voltage inputs based on voltage sensors

- Phase current inputs based on current sensors (Rogowsky coil)

- Residual current input based on conventional CT

Std. conf. and I/O options

4 CT (Io 0.2/1A) + 3 VT + 14 BI + 13 BO A AA A

4 CT (Io 0.2/1A) + 3 VT + 8 BI + 10 BO A AA N

4 CT (Io 0.2/1A) + 6 VD 12 BI + 10 BO B AB N

3 Current sensor + 3 Voltage sensor + Io (0.2/1A) + 8 BI + 10 BO C AC N

Communication modules (Serial/Ethernet)

RS-232/485 + input for IRIG-B + Ethernet 100Base-TX (1 x RJ45) A B

Serial glass fibre (ST) + Ethernet 100Base-TX and -FX (1 x RJ-45 + 2 x LC) B E

RS-232/485 + RS-485 + input for IRIG-B

+ Ethernet 100Base-TX (1 x RJ-45)C B

Ethernet 100Base-FX (1 x LC) N A

Ethernet 100Base-TX (1 x RJ-45) N B

Ethernet 100Base-TX (3 x RJ-45) N D

Communication protocols

IEC 61850 A

IEC 61850 + IEC 60870-5-101 (slave) + IEC 60870-5-104 (slave) B

IEC 61850 + DNP3 TCP/IP (slave) + Modbus (slave) C

Language

English (IEC) + English (ANSI) 1

Front Panel

Small LCD with IEC symbols A

Large LCD with single line diagram (SLD) and IEC symbols B

Large LCD with single line diagram (SLD) and ANSI symbols F

Option 1

Directional earth-fault protection A

Directional overcurrent protection and directional earth-fault protection B

Admittance based earth-fault protection, directional overcurrent protection and

directional earth-fault protectionC

Wattmetric based earth-fault protection, directional overcurrent protection and

directional earth-fault protectionD

Harmonics based earth-fault protection, directional overcurrent protection and

directional earth-fault protectionE

None N

Option 2

Voltage and Frequency protection with load shedding and restoration A

None N

Option 3

Auto-reclosing A

Page 32: ABBOfflineOrderNumberTool_Ver_15.41b_758059_ENg.xls

Power quality B

Power quality and auto-reclosing C

None N

Power supply

24-60 VDC 2

Version

Version 1.0 X F

Mounting accessories and arc sensors for REC615

Description Order No.

Semi-flush mounting kit 1MRS050696

Wall mounting kit 1MRS050697

Inclined semi-flush mounting kit 1MRS050831

19” rack mounting kit with cut-out for one IED 1MRS050694

19” rack mounting kit with cut-out for two IEDs 1MRS050695

0

0

0

Price

EUR

0

0

Page 33: ABBOfflineOrderNumberTool_Ver_15.41b_758059_ENg.xls

REF620Feeder Protection and Control

Selected Order No. N B F N B N X F

Instructions / Order No. Pos. 1 2 3 4 5/6 7/8 9 10 11 12 13 14 15 16 17 18 EUR

IED

620 series IED (including case) N

Standard

IEC B

Main application

Feeder protection and control F

Standard configuration (descriptions in short)

Example configuration N

Analog inputs and Binary I/O options

4I (Io 1/5A) + 5U + 24BI + 14BO AA

4I (Io 0.2/1A) + 5U + 24BI + 14BO AB

Sensors (3Is + 3Us + 1CT) + 16BI + 14BO AC

Analog inputs and Binary I/O options

Optional I/Os 8BI+ 4BO AA

Optional RTDs 6RTD in + 2mA in AB

Optional Fast I/Os 8BI + 3HSO AC

No optional board NN

Communication modules (Serial/Ethernet)

Serial RS-485, incl. an input for IRIG-B + Ethernet 100Base-FX (1 x LC) A A

Serial RS-485, incl. an input for IRIG-B + Ethernet 100Base-TX (1 x RJ-45) A B

Serial RS-485, incl. an input for IRIG-B A N

Serial glass fibre (ST) + Serial RS-485 connector, RS-232/485 D-Sub 9

connector + input for IRIG-B (cannot be combined with arc protection)B N

Serial glass fibre (ST) + Ethernet 100Base-TX (1 x RJ-45) + Serial RS-485

connector, RS-232/485 D-Sub 9 connector + input for IRIG-B (cannot be

combined with arc protection)

B B

Serial glass fibre (ST) + Ethernet 100Base-TX (3 x RJ-45) with HSR/PRP B D

Serial glass fibre (ST) + Ethernet 100Base-TX and -FX (2 x RJ-45 + 1 x LC)

with HSR/PRPB C

Serial glass fibre (ST) + Ethernet 100Base-TX and -FX (1 x RJ-45 + 2 x LC)

with HSR/PRPB E

Ethernet 100Base-FX (1 x LC) N A

Ethernet 100Base-TX (1 x RJ-45) N B

Ethernet 100Base-TX and -FX (2 x RJ-45 + 1 x LC) with HSR/PRP N C

Ethernet 100Base-TX (3 x RJ-45) with HSR/PRP N D

Ethernet 100Base-TX and -FX (1 x RJ-45 + 2 x LC) with HSR/PRP N E

No Communication Module N N

Communication protocols

IEC 61850 (for Ethernet communication modules and IEDs

without a communication module )

Not allowed when Order No. 9/10 = AN,

BB, BC, BD, BE or BNA

Modbus (for Ethernet/serial or Ethernet + serial communication modules) Not allowed when Order No. 9/10 = NN B

IEC 61850 + Modbus (for Ethernet or serial + Ethernet communication

modules)

Not allowed when Order No. 9/10 =

AN, BN or NNC

IEC 60870-5-103 (for serial or Ethernet + serial communication modules)Not allowed when Order No. 9/10 = AA,

AB, BB, BC, BD, BE, NA, NB, NC, ND,

NE or NN

D

DNP (for Ethernet/serial or Ethernet + serial communication modules) Not allowed when Order No. 9/10 = NN E

IEC 61850 + IEC 60870-5-103

(for serial + Ethernet communication modules)

Not allowed when Order No. 9/10 =

AN, BN, NA, NB, NC, ND, NE or NNG

IEC 61850 + DNP3

(for Ethernet or serial + Ethernet communication modules)

Not allowed when Order No. 9/10 =

AN, BN or NNH

Language

English IEC and ANSI 1

English IEC - German 3

English IEC - Swedish 4

English IEC - Spanish 5

English IEC - Polish 7

English IEC - Portuguese (Brasilian) 8

English IEC - French C

English IEC - Czech E

Page 34: ABBOfflineOrderNumberTool_Ver_15.41b_758059_ENg.xls

REF620Feeder Protection and Control

Selected Order No. N B F N B N X F

Instructions / Order No. Pos. 1 2 3 4 5/6 7/8 9 10 11 12 13 14 15 16 17 18 EUR

Front Panel

Large LCD, (10 rows) with single line diagram (SLD) B

Option 1

Arc protectionNot allowed when digit pair 9/10 = BB,

BN or NNB

None N

Option 2

None N

Power supply

48...250 V DC, 100...240 V AC 1

24…60 V DC 2

Version

Version 2.0 X F

Mounting accessories for REF620

Description Order No.

Semi-flush mounting kit 2RCA030573A0001

Wall mounting kit 2RCA030894A0001

19” Mounting panel kit 2RCA031135A0001

Mounting bracket for one IED in 4U Combiflex (RHGT 19” variant C) 2RCA032826A0001

Price

EUR

0

0

0

0

Page 35: ABBOfflineOrderNumberTool_Ver_15.41b_758059_ENg.xls

REM620Motor Protection and Control

Selected Order No. N B M N B N X F

Instructions / Order No. Pos. 1 2 3 4 5/6 7/8 9 10 11 12 13 14 15 16 17 18 EUR

IED

620 series IED (including case) N

Standard

IEC B

Main application

Motor protection and control M

Standard configuration (descriptions in short)

Example configuration N

Analog inputs and Binary I/O options

7I (I0 1/5 A) + 5U + 12BI + 10BO + 6RTD in + 2mA in AA

7I (I0 0,2/1 A) + 5U + 12BI + 10BO + 6RTD in + 2mA in AB

Analog inputs and Binary I/O options

Optional I/Os 8BI+ 4BO AA

Optional RTDs 6RTD in + 2mA in AB

Optional Fast I/Os 8BI + 3HSO AC

No optional board NN

Communication modules (Serial/Ethernet)

Serial RS-485, incl. an input for IRIG-B + Ethernet 100Base-FX (1 x LC) A A

Serial RS-485, incl. an input for IRIG-B + Ethernet 100Base-TX (1 x RJ-45) A B

Serial RS-485, incl. an input for IRIG-B A N

Serial glass fibre (ST) + Serial RS-485 connector, RS-232/485 D-Sub 9

connector + input for IRIG-B (cannot be combined with arc protection)B N

Serial glass fibre (ST) + Ethernet 100Base-TX (1 x RJ-45) + Serial RS-485

connector, RS-232/485 D-Sub 9 connector + input for IRIG-B (cannot be

combined with arc protection)

B B

Serial glass fibre (ST) + Ethernet 100Base-TX (3 x RJ-45) with HSR/PRP B D

Serial glass fibre (ST) + Ethernet 100Base-TX and -FX (2 x RJ-45 + 1 x LC)

with HSR/PRPB C

Serial glass fibre (ST) + Ethernet 100Base-TX and -FX (1 x RJ-45 + 2 x LC)

with HSR/PRPB E

Ethernet 100Base-FX (1 x LC) N A

Ethernet 100Base-TX (1 x RJ-45) N B

Ethernet 100Base-TX and -FX (2 x RJ-45 + 1 x LC) with HSR/PRP N C

Ethernet 100Base-TX (3 x RJ-45) with HSR/PRP N D

Ethernet 100Base-TX and -FX (1 x RJ-45 + 2 x LC) with HSR/PRP N E

No Communication module N N

Communication protocols

IEC 61850 (for Ethernet communication modules and IEDs

without a communication module )

Not allowed when Order No. 9/10 = AN,

BB, BC, BD, BE or BNA

Modbus (for Ethernet/serial or Ethernet + serial communication modules) Not allowed when Order No. 9/10 = NN B

IEC 61850 + Modbus (for Ethernet or serial + Ethernet communication

modules)

Not allowed when Order No. 9/10 = AN,

BN or NNC

IEC 60870-5-103 (for serial or Ethernet + serial communication modules)Not allowed when Order No. 9/10 = AA,

AB, BB, BC, BD, BE, NA, NB, NC, ND,

NE or NN

D

DNP (for Ethernet/serial or Ethernet + serial communication modules) Not allowed when Order No. 9/10 = NN E

IEC 61850 + IEC 60870-5-103

(for serial + Ethernet communication modules)

Not allowed when Order No. 9/10 = AN,

BN, NA, NB, NC, ND, NE or NNG

IEC 61850 + DNP3

(for Ethernet or serial + Ethernet communication modules)

Not allowed when Order No. 9/10 = AN,

BN or NNH

Language

English IEC and ANSI 1

English IEC - German 3

English IEC - Swedish 4

English IEC - Spanish 5

English IEC - Polish 7

English IEC - Portuguese (Brasilian) 8

English IEC - French C

English IEC - Czech E

Front Panel

Page 36: ABBOfflineOrderNumberTool_Ver_15.41b_758059_ENg.xls

REM620Motor Protection and Control

Selected Order No. N B M N B N X F

Instructions / Order No. Pos. 1 2 3 4 5/6 7/8 9 10 11 12 13 14 15 16 17 18 EUR

Large LCD, (10 rows) with single line diagram (SLD) B

Option 1

Arc protectionNot allowed when Order No. 9/10 = BB,

BN or NNB

None N

Option 2

None N

Power supply

48...250 V DC, 100...240 V AC 1

24…60 V DC 2

Version

Version 2.0 X F

Mounting accessories for REM620

Description Order No.

Semi-flush mounting kit 2RCA030573A0001

Wall mounting kit 2RCA030894A0001

19” Mounting panel kit 2RCA031135A0001

Mounting bracket for one IED in 4U Combiflex (RHGT 19” variant C) 2RCA032826A0001

Price

EUR

0

0

0

0

Page 37: ABBOfflineOrderNumberTool_Ver_15.41b_758059_ENg.xls

RET620Transformer Protection and Control

Selected Order No. N B T N AA B X F

Instructions / Order No. Pos. 1 2 3 4 5/6 7/8 9 10 11 12 13 14 15 16 17 18 EUR

IED

620 series IED (including case) N

Standard

IEC B

Main application

Transformer protection and control T

Functional application

Example configuration N

Analog inputs and outputs

8I (I0 1/5 A) + 6U + 8BI + 13BO + 2RTD in + 1mA in AA

Optional board

Optional I/Os 8BI+ 4BO AA

Optional RTDs 6RTD in + 2mA in AB

Optional Fast I/Os 8BI + 3HSO AC

No optional board NN

Communication modules (Serial/Ethernet)

Serial RS-485, incl. an input for IRIG-B + Ethernet 100Base-FX (1 x LC) A A

Serial RS-485, incl. an input for IRIG-B + Ethernet 100Base-TX (1 x RJ-45) A B

Serial RS-485, incl. an input for IRIG-B A N

Serial glass fibre (ST) + Serial RS-485 connector, RS-232/485 D-Sub 9

connector + input for IRIG-B (cannot be combined with arc protection)B N

Serial glass fibre (ST) + Ethernet 100Base-TX (1 x RJ-45) + Serial RS-485

connector, RS-232/485 D-Sub 9 connector + input for IRIG-B (cannot be

combined with arc protection)

B B

Serial glass fibre (ST) + Ethernet 100Base-TX (3 x RJ-45) with HSR/PRP B D

Serial glass fibre (ST) + Ethernet 100Base-TX and -FX (2 x RJ-45 + 1 x LC)

with HSR/PRPB C

Serial glass fibre (ST) + Ethernet 100Base-TX and -FX (1 x RJ-45 + 2 x LC)

with HSR/PRPB E

Ethernet 100Base-FX (1 x LC) N A

Ethernet 100Base-TX (1 x RJ-45) N B

Ethernet 100Base-TX and -FX (2 x RJ-45 + 1 x LC) with HSR/PRP N C

Ethernet 100Base-TX (3 x RJ-45) with HSR/PRP N D

Ethernet 100Base-TX and -FX (1 x RJ-45 + 2 x LC) with HSR/PRP N E

No Communication module N N

Communication protocols

IEC 61850 (for Ethernet communication modules and IEDs

without a communication module )

Not allowed when Order No. 9/10 = AN,

BB, BC, BD, BE or BNA

Modbus (for Ethernet/serial or Ethernet + serial communication modules) Not allowed when Order No. 9/10 = NN B

IEC 61850 + Modbus (for Ethernet or serial + Ethernet communication

modules)

Not allowed when Order No. 9/10 = AN,

BN or NNC

IEC 60870-5-103 (for serial or Ethernet + serial communication modules)Not allowed when Order No. 9/10 = AA,

AB, BB, BC, BD, BE, NA, NB, NC, ND,

NE or NN

D

DNP (for Ethernet/serial or Ethernet + serial communication modules) Not allowed when Order No. 9/10 = NN E

IEC 61850 + IEC 60870-5-103

(for serial + Ethernet communication modules)

Not allowed when Order No. 9/10 = AN,

BN, NA, NB, NC, ND, NE or NNG

IEC 61850 + DNP3

(for Ethernet or serial + Ethernet communication modules)

Not allowed when Order No. 9/10 = AN,

BN or NNH

Language

English IEC and ANSI 1

English IEC - German 3

English IEC - Swedish 4

English IEC - Spanish 5

English IEC - Polish 7

English IEC - Portuguese (Brasilian) 8

English IEC - French C

English IEC - Czech E

Front Panel

Page 38: ABBOfflineOrderNumberTool_Ver_15.41b_758059_ENg.xls

RET620Transformer Protection and Control

Selected Order No. N B T N AA B X F

Instructions / Order No. Pos. 1 2 3 4 5/6 7/8 9 10 11 12 13 14 15 16 17 18 EUR

Large LCD with Single Line Diagram - IEC B

Option 1

Arc protectionNot allowed when digit pair 9/10 = BB,

BN or NNB

None N

Option 2

Automatic voltage regulator A

None N

Power supply

48...250 V DC, 100...240 V AC 1

24…60 V DC 2

Version

Version 2.0 X F

Mounting accessories for RET620

Description Order No.

Semi-flush mounting kit 2RCA030573A0001

Wall mounting kit 2RCA030894A0001

19” Mounting panel kit 2RCA031135A0001

Mounting bracket for one IED in 4U Combiflex (RHGT 19” variant C) 2RCA032826A0001

Price

EUR

0

0

0

0

Page 39: ABBOfflineOrderNumberTool_Ver_15.41b_758059_ENg.xls

REF630Feeder Protection and Control

Selected Order No. B F Z X C

Instructions / Order No. Pos. 1 2 3 4 5/6 7/8 9 10 11 12 13 14 15 16 17 18 EUR

IED

630 series IED, 4U half 19” housing S

630 series IED, 6U half 19” housing T

630 series IED, 4U half 19” housing with connector set U

630 series IED, 6U half 19” housing with connector set V

Standard

IEC B

Main application

Feeder protection and control F

Preconfiguration (descriptions in short)

A = Preconfiguration A for open/closed ring feeder A

B = Preconfiguration B for radial overhead/mixed line feeder B

C = Preconfiguration C for ring/meshed feederDistance option to be

selected Order No. 14 = B or D or F

or Order No. 15 = D

C

D = Preconfiguration D for bus sectionalizer D

N = None N

Analog input options

Available analog input option for

Preconfigurations A, B, C, D, N

AB = 4 I (I0 1/5A) + 1 I (I0 0.1/0.5A) + 4 U AB

Available analog inputs options for

"preconfiguration" N only

AA = 4 I (I0 1/5A) + 5 U Possible when Order No. 4 = N N AA

AC = 3 I (I0 1/5A) + 1 I (I0 0.1/0.5A) + 5 U Possible when Order No. 4 = N N AC

BA = 4 I (I0 1/5 A) + 5 U + 8 mA in/RTD + 4 mA out Possible when Order No. 4 = N N BA

BB = 4 I (I0 1/5 A) + 1 I (I0 0.1/0.5 A) + 4 U + 8 mA in/RTD + 4 mA out Possible when Order No. 4 = N N BB

BC = 3 I (I0 1/5 A) + 1 I (I0 0.1/0.5 A) + 5 U + 8 mA in/RTD + 4 mA out Possible when Order No. 4 = N N BC

Binary input/output options

Available binary input/output options for all

Preconfigurations A, B, C, D and N

AB = 23 BI + 18 BO AB

AC = 32 BI + 27 BONOT possible if Order No. 1 = S or U

and Order No. 5/6 = BA, BB or BCAC

AD = 41 BI + 36 BOOnly for 6U half 19” housing

Order No. 1 =T or VAD

AE = 50 BI + 45 BOOnly for 6U half 19” housing

Order No. 1 =T or V and

Order No. 5/6 = AA, AB or AC

AE

Available binary input/output options for

"preconfiguration" N only

AA = 14 BI + 9 BO Possible when Order No. 4 = N N AA

Communication serial (for future use)

Glass fibre (ST connector) A

Plastic fibre (snap-in connector) B

Communication Ethernet

Ethernet 100BaseFX (LC) A

Ethernet 100BaseTX (RJ-45) B

Communication protocol

IEC 61850 A

IEC 61850 and DNP3 TCP/IP B

IEC 61850 and IEC 60870-103 C

Language

English and Chinese Z

Front Panel

Integrated local HMI Available when Order No. 1 = S or U A

Detached local HMI, 1 m cable B

Page 40: ABBOfflineOrderNumberTool_Ver_15.41b_758059_ENg.xls

REF630Feeder Protection and Control

Selected Order No. B F Z X C

Instructions / Order No. Pos. 1 2 3 4 5/6 7/8 9 10 11 12 13 14 15 16 17 18 EUR

Detached local HMI, 2 m cable C

Detached local HMI, 3 m cable D

Detached local HMI, 4 m cable E

Detached local HMI, 5 m cable F

No local HMI N

Option 1

Fault locator and synchro-checkAvailable options for Order No. 15

restricted to: D, E or NA

Fault locator and distance protectionAvailable options for Order No. 15

restricted to: B, E or NB

Fault locator and power qualityAvailable options for Order No. 15

restricted to: B, D or NC

Synchro-check and distance protectionAvailable options for Order No. 15

restricted to: A, E or ND

Synchro-check and power qualityAvailable options for Order No. 15

restricted to: A, D or NE

Distance protection and power qualityAvailable options for Order No. 15

restricted to: A, B or NF

All optionsAvailable options for Order No. 15

restricted to: NZ

None N N

Option 2

Fault locator A

Synchro-check B

Distance protection D

Power quality E

None N

Power supply

48...125 V DC A A

110...250 V DC, 100...240 V AC B

Vacant digit

Vacant X

Version

Version 1.2 C

Connector sets for REF630 Order No.

Connector set for REF630 4U half 19" housing

IED including analog input variant

4I + 5U (Io 1/5A), 5I + 4U (Io 0.1/0.5A) or 4I + 5U (Io 0.1/0.5A)

2RCA021735

Connector set for REF630 6U half 19" housing

IED including analog input variant

4I + 5U (Io 1/5A), 5I + 4U (Io 0.1/0.5A) or 4I + 5U (Io 0.1/0.5A)

2RCA021736

Mounting accessories for 630 series Order No.

Flush mounting kit for one 4U half 19” housing IED 1KHL400040R0001

Semi-flush mounting kit for one 4U half 19” housing IED 1KHL400444R0001

Wall-mounting kit (cabling towards the mounting wall) for one 4U

half 19” housing IED1KHL400067R0001

Wall-mounting kit (cabling to the front) for one 4U half 19” housing

IED1KHL400449R0001

19" rack mounting kit for one 4U half 19” housing IED 1KHL400236R0001

19" rack mounting kit for two 4U half 19” housing IEDs 1KHL400237R0001

Overhead/ceiling mounting kit (with cable space) for one 4U half

19” housing IED1KHL400450R0001

Wall-mounting kit for direct rear wall mounting (with cabling to the

front) of one 6U half 19" housing IED1KHL400452R0001

Wall-mounting kit (with cabling towards the mounting wall) for one

6U half 19" housing IED1KHL400200R0001

Overhead/ceiling mounting kit (with cable space) for one 6U half

19" housing IED1KHL400464R0001

Test switch mounting accessories for 630 series Order No.

0

0

0

0

0

EUR

0

0

Price

EUR

0

Price

0

0

Price

EUR

0

0

Page 41: ABBOfflineOrderNumberTool_Ver_15.41b_758059_ENg.xls

REF630Feeder Protection and Control

Selected Order No. B F Z X C

Instructions / Order No. Pos. 1 2 3 4 5/6 7/8 9 10 11 12 13 14 15 16 17 18 EUR

19" rack mounting kit for one RTXP8 test switch (the test switch is

not included in the delivery)1KHL400465R0001

19" rack mounting kit for one RTXP18 test switch (the test switch

is not included in the delivery)1KHL400467R0001

19" rack mounting kit for one RTXP24 test switch (the test switch

is not included in the delivery)1KHL400469R0001 0

0

0

Page 42: ABBOfflineOrderNumberTool_Ver_15.41b_758059_ENg.xls

REM630Motor Protection and Control

Selected Order No. B M Z X C

Instructions / Order No. Pos. 1 2 3 4 5/6 7/8 9 10 11 12 13 14 15 16 17 18 EUR

IED

630 series IED, 4U half 19” housing S

630 series IED, 6U half 19” housing T

630 series IED, 4U half 19” housing with connector set U

630 series IED, 6U half 19” housing with connector set V

Standard

IEC B

Main application

Motor protection and control M

Functional application,preconfiguration

A = Preconfiguration A for asynchronous motors A

B = Preconfiguration B for asynchronous motors

including differential protection

Possible when Order No. 14 = A or C or

Order No. 15 = CB

N = None N

Analog input options

Available analog input option for

Preconfigurations A and N

AA = 4 I (I0 1/5A) + 1 I (I0 0.1/0.5A) + 4 U Possible when Order No. 4 = A or N AA

Available analog input option for

Preconfigurations B and N

AB = 7I (Io 1/5A) + 3U Possible when Order No. 4 = B or N AB

Available analog input option for

Preconfiguration N only

AC = 8I (Io 1/5A) + 2U Possible when Order No. 4 = N N AC

BA = 4 I (I0 1/5A) + 1 I (I0 0.1/0.5A) + 4 U +

8mA in/RTD + 4mA outPossible when Order No. 4 = N or A BA

BB = 7I (Io 1/5A) + 3U + 8mA in/RTD + 4mA out Possible when Order No. 4 = N or A BB

BC = 8I (Io 1/5A) + 2U + 8mA in/RTD + 4mA out Possible when Order No. 4 = N N BC

Binary input/output options

Available binary input/output options for

preconfigurations A and N

AA = 14 BI + 9 BO AA

AB = 23 BI + 18 BO AB

AC = 32 BI + 27 BONOT possible if Order No. 1 = S or U

and Order No. 5/6 = BA, BB or BCAC

AD = 41 BI + 36 BOOnly for 6U half 19” housing

Order No. 1 = T or VAD

AE = 50 BI + 45 BO

Only for 6U half 19” housing

Order No. 1 = T or V

and Order No. 5/6 = AA, AB or AC

AE

Communication serial (for future use)

Glass fibre (ST connector) A

Plastic fibre (snap-in connector) B

Communication Ethernet

Ethernet 100BaseFX (LC) A

Ethernet 100BaseTX (RJ-45) B

Communication protocol

IEC 61850 A

IEC 61850 and DNP3 TCP/IP B

IEC 61850 and IEC 60870-103 C

Language

English and Chinese Z

Front Panel

Integrated local HMI A Available when Order No. 1 = S or U A

Detached local HMI, 1 m cable B

Detached local HMI, 2 m cable C

Detached local HMI, 3 m cable D

Detached local HMI, 4 m cable E

Page 43: ABBOfflineOrderNumberTool_Ver_15.41b_758059_ENg.xls

REM630Motor Protection and Control

Selected Order No. B M Z X C

Instructions / Order No. Pos. 1 2 3 4 5/6 7/8 9 10 11 12 13 14 15 16 17 18 EUR

Detached local HMI, 5 m cable F

No local HMI N

Option 1

Underfrequency and overfrequency protection (including

rate of change) and phase-sequence voltage functions

and Stabilized differential protection

Available options for

Order No. 15 = D or NA

Underfrequency and overfrequency protection

(including rate of change) and Additional functions

for synchronous motor

Available options for

Order No. 15 = C or NB

Stabilized differential protection and Additional functions for synchronous

motor

Available options for

Order No. 15 = B or NC

All optionsAvailable option for Order No. 15

restricted to: NZ

None N N

Option 2

Underfrequency and overfrequency protection

(including rate of change)B

Stabilized differential protection C

Additional functions for synchronous motor D

None N

Power supply

48...125 V DC A A

110...250 V DC, 100...240 V AC B

Vacant digit

Vacant X

Version

Version 1.2 C

Connector sets for REM630 Order No.

Connector set for REM630 4U half 19" housing

IED including analog input variant

4I + 5U (Io 1/5A), 5I + 4U (Io 0.1/0.5A) or 4I + 5U (Io 0.1/0.5A)

2RCA021735

Connector set for REM630 6U half 19" housing

IED including analog input variant

4I + 5U (Io 1/5A), 5I + 4U (Io 0.1/0.5A) or 4I + 5U (Io 0.1/0.5A)

2RCA021736

Connector set for REM630 4U half 19" housing IED including

analog input variant 7I (I0 1/5A) + 3U)2RCA023041

Connector set for REM630 6U half 19" housing IED including

analog input variant 7I (I0 1/5A) + 3U)2RCA023042

Connector set for REM630 4U half 19" housing IED including

analog input variant

8I (I0 1/5A) + 2U or 7I (I0 1/5A) + 1I (I0 0.1/0.5A) + 2U)

2RCA023039

Connector set for REM630 6U half 19" housing IED including

analog input variant

8I (I0 1/5A) + 2U or 7I (I0 1/5A) + 1I (I0 0.1/0.5A) + 2U)

2RCA023040

Mounting accessories for 630 series Order No.

Flush mounting kit for one 4U half 19” housing IED 1KHL400040R0001

Semi-flush mounting kit for one 4U half 19” housing IED 1KHL400444R0001

Wall-mounting kit (cabling towards the mounting wall) for one 4U

half 19” housing IED1KHL400067R0001

Wall-mounting kit (cabling to the front) for one 4U half 19” housing

IED1KHL400449R0001

19" rack mounting kit for one 4U half 19” housing IED 1KHL400236R0001

19" rack mounting kit for two 4U half 19” housing IEDs 1KHL400237R0001

Overhead/ceiling mounting kit (with cable space) for one 4U half 19”

housing IED1KHL400450R0001

Wall-mounting kit for direct rear wall mounting (with cabling to the

front) of one 6U half 19" housing IED1KHL400452R0001

Wall-mounting kit (with cabling towards the mounting wall) for one

6U half 19" housing IED1KHL400200R0001

Overhead/ceiling mounting kit (with cable space) for one 6U half 19"

housing IED1KHL400464R0001

Price

EUR

0

0

0

0

0

0

0

0

Price

EUR

0

0

0

0

0

0

0

0

Price

Page 44: ABBOfflineOrderNumberTool_Ver_15.41b_758059_ENg.xls

REM630Motor Protection and Control

Selected Order No. B M Z X C

Instructions / Order No. Pos. 1 2 3 4 5/6 7/8 9 10 11 12 13 14 15 16 17 18 EUR

Test switch mounting accessories for 630 series Order No.

19" rack mounting kit for one RTXP8 test switch (the test switch is

not included in the delivery)1KHL400465R0001

19" rack mounting kit for one RTXP18 test switch (the test switch is

not included in the delivery)1KHL400467R0001

19" rack mounting kit for one RTXP24 test switch (the test switch is

not included in the delivery)1KHL400469R0001

Current injection device for earth-fault protection of a

synchronous machine rotor Order No.

Electronic device for rotor earth fault detection in the excitation

circuit of synchronous machine.REK 510-AA

EUR

0

0

EUR

0

0

Price

Page 45: ABBOfflineOrderNumberTool_Ver_15.41b_758059_ENg.xls

RET630Transformer Protection and Control

Selected Order No. B T Z X C

Instructions / Order No. Pos. 1 2 3 4 5/6 7/8 9 10 11 12 13 14 15 16 17 18 EUR

IED

630 series IED, 4U half 19” housing S

630 series IED, 6U half 19” housing T

630 series IED, 4U half 19” housing with connector set U

630 series IED, 6U half 19” housing with connector set V

Standard

IEC B

Main application

Transformer protection and control T

Preconfiguration (descriptions in short)

A = Preconfiguration A for two-winding transformers A

B = Preconfiguration B for two-winding transformers,

including numerical REF protectionB

N = None N

Analog input options

Available analog input option for

Preconfigurations A and N

AA = 7 I (I0 1/5A) + 3 U Possible when Order No. 4 = A or N AA

Available analog input option for

Preconfigurations B and N

AB = 8 I (I0 1/5A) + 2 U Possible when Order No. 4 = B or N AB

Available analog inputs option for

"preconfiguration" N only

AC = 7 I (I0 1/5A) + 1 I (I0 0.1/0.5A) + 2 U Possible when Order No. 4 = N N AC

BA = 7 I (I0 1/5A) + 3U + 8 mA in/RTD + 4 mA out Possible when Order No. 4 = N N BA

BB = 8 I (I0 1/5A) + 2U + 8 mA in/RTD + 4 mA out Possible when Order No. 4 = N N BB

BC = 7 I (I0 1/5A) + 1 I (I0 0.1/0.5A) + 2U +

8 mA in/RTD + 4 mA outPossible when Order No. 4 = N N BC

Binary input/output options

Available binary input/output options for all

Preconfigurations A, B, C, D and N

AA = 14 BI + 9 BO Possible when Order No. 4 = N AA

AB = 23 BI + 18 BO AB

AC = 32 BI + 27 BONOT possible when Order No. 1 = S or U

and Order No. 5/6 = BA, BB or BCAC

AD = 41 BI + 36 BOOnly for 6U half 19” housing

Order No. 1 = T or VAD

AE = 50 BI + 45 BO

Only for 6U half 19” housing

Order No. 1 = T or V

and Order No. 5/6 = AA, AB or AC

AE

Communication serial (for future use)

Glass fibre (ST connector) A

Plastic fibre (snap-in connector) B

Communication Ethernet

Ethernet 100BaseFX (LC) A

Ethernet 100BaseTX (RJ-45) B

Communication protocol

IEC 61850 A

IEC 61850 and DNP3 TCP/IP B

IEC 61850 and IEC 60870-103 C

Language

English and Chinese Z

Front Panel

Integrated local HMI A Available when Order No. 1 = S or U A

Detached local HMI, 1 m cable B

Page 46: ABBOfflineOrderNumberTool_Ver_15.41b_758059_ENg.xls

RET630Transformer Protection and Control

Selected Order No. B T Z X C

Instructions / Order No. Pos. 1 2 3 4 5/6 7/8 9 10 11 12 13 14 15 16 17 18 EUR

Detached local HMI, 2 m cable C

Detached local HMI, 3 m cable D

Detached local HMI, 4 m cable E

Detached local HMI, 5 m cable F

No local HMI N

Option 1

Automatic voltage regulator and Under impedance protectionAvailable options for

Order No. 15 = D or NA

Automatic voltage regulator and Over-excitation protectionAvailable options for

Order No. 15 = C or NB

Under impedance and Over-excitation protectionAvailable options for

Order No. 15 = B or NC

All optionAvailable option for Order No. 15

restricted to: NZ

None N

Option 2

Automatic voltage regulator B

Under impedance protection C

Over-excitation protection D

None N

Power supply

48...125 V DC A A

110...250 V DC, 100...240 V AC B

Vacant digit

Vacant X

Version

Version 1.2 C

Connector sets for RET630 Order No.

Connector set for RET630 4U half 19" housing IED

including analog input variant 7I (I0 1/5A) + 3U)2RCA023041

Connector set for RET630 6U half 19" housing IED

including analog input variant 7I (I0 1/5A) + 3U)2RCA023042

Connector set for RET630 4U half 19" housing IED

including analog input variant

8I (I0 1/5A) + 2U or 7I (I0 1/5A) + 1I (I0 0.1/0.5A) + 2U)

2RCA023039

Connector set for RET630 6U half 19" housing IED

including analog input variant

8I (I0 1/5A) + 2U or 7I (I0 1/5A) + 1I (I0 0.1/0.5A) + 2U)

2RCA023040

Mounting accessories for 630 series Order No.

Flush mounting kit for one 4U half 19” housing IED 1KHL400040R0001

Semi-flush mounting kit for one 4U half 19” housing IED 1KHL400444R0001

Wall-mounting kit (cabling towards the mounting wall) for one

4U half 19” housing IED1KHL400067R0001

Wall-mounting kit (cabling to the front) for one

4U half 19” housing IED1KHL400449R0001

19" rack mounting kit for one 4U half 19” housing IED 1KHL400236R0001

19" rack mounting kit for two 4U half 19” housing IEDs 1KHL400237R0001

Overhead/ceiling mounting kit (with cable space) for one 4U

half 19” housing IED1KHL400450R0001

Wall-mounting kit for direct rear wall mounting (with cabling to

the front) of one 6U half 19" housing IED1KHL400452R0001

Wall-mounting kit (with cabling towards the mounting wall) for

one 6U half 19" housing IED1KHL400200R0001

Overhead/ceiling mounting kit (with cable space) for one 6U

half 19" housing IED1KHL400464R0001

0

0

0

0

Price

0

0

0

0

0

0

0

0

Price

EUR

Price

EUR

0

0

Page 47: ABBOfflineOrderNumberTool_Ver_15.41b_758059_ENg.xls

RET630Transformer Protection and Control

Selected Order No. B T Z X C

Instructions / Order No. Pos. 1 2 3 4 5/6 7/8 9 10 11 12 13 14 15 16 17 18 EUR

Test switch mounting accessories for 630 series Order No.

19" rack mounting kit for one RTXP8 test switch (the test

switch is not included in the delivery)1KHL400465R0001

19" rack mounting kit for one RTXP18 test switch (the test

switch is not included in the delivery)1KHL400467R0001

19" rack mounting kit for one RTXP24 test switch (the test

switch is not included in the delivery)1KHL400469R0001 0

EUR

0

0

Page 48: ABBOfflineOrderNumberTool_Ver_15.41b_758059_ENg.xls

REG630Generator Protection and Control

Selected Order No. B G Z N X C

Instructions / Order No. Pos. 1 2 3 4 5/6 7/8 9 10 11 12 13 14 15 16 17 18 EUR

IED

630 series IED, 4U half 19” housing S

630 series IED, 6U half 19” housing T

630 series IED, 4U half 19” housing with connector set U

630 series IED, 6U half 19” housing with connector set V

Standard

IEC B

Main Application

Generator protection and control G

Functional Application

N = No pre-configuration N

A = Pre-configuration A A

Analog Inputs/Outputs

AA = 5I + 4U Possible if Order No. 4 = N AA

AB = 7I + 3U (Io 1/5A) AB

AC = 8I + 2U (Io 1/5A) Possible if Order No. 4 = N AC

BA = 5I + 4U + 8mAin/RTD + 4mAout Possible if Order No. 4 = N BA

BB = 7I + 3U (Io 1/5A) + 8mAin/RTD + 4mAout BB

BC = 8I + 2U (Io 1/5A) + 8mAin/RTD + 4mAout Possible if Order No. 4 = N BC

Binary I/O

AA = 14BI + 9BO AA

AB = 23BI + 18BO AB

AC = 32BI + 27BONot possible if Order No. 1 = S or U

and Order No. 5/6 = BA, BB or BCAC

AD = 41BI + 36BOOnly for 6U half 19” housing

Order No. 1 =T or VAD

AE = 50BI + 45BO

Only for 6U half 19” housing

Order No. 1 =T or V and Order No. 5/6 =

AA, AB or AC

AE

Communication Serial

Serial glass fibre (ST connector) A

Serial plastic fibre (Snap-in connector) B

Communication Ethernet

Ethernet 100BaseFX (LC) A

Ethernet 100BaseTX (RJ-45) B

Communication Protocol

IEC 61850 A

IEC 61850 and DNP3 TCP/IP B

IEC 61850 and IEC 60870-103 C

Language

Language package Z

Front Panel

Integrated local HMI Available when Order No. 1 = S or U A

Detached local HMI, 1 m cable B

Detached local HMI, 2 m cable C

Detached local HMI, 3 m cable D

Detached local HMI, 4 m cable E

Detached local HMI, 5 m cable F

No local HMI Not available for pre configuration A N

Option 1

No options N

Transformer differential protection for two-winding transformers Not available if Order No. 5/6 = AA or BA A

Third Harmonic Based Stator Earth Fault Protection B

Page 49: ABBOfflineOrderNumberTool_Ver_15.41b_758059_ENg.xls

REG630Generator Protection and Control

Selected Order No. B G Z N X C

Instructions / Order No. Pos. 1 2 3 4 5/6 7/8 9 10 11 12 13 14 15 16 17 18 EUR

All options Not available if Order No. 5/6 = AA or BA Z

Option 2

No options N

Power Supply

48...125 V DC A A

110...250 V DC, 100...240 V AC B

Vacant Digit

Vacant X

Version

Version 1.2 C

Connector sets for REG630 Order No.

Connector set for REG630 4U half 19" housing

IED including analog input variant

4I + 5U (Io 1/5A), 5I + 4U (Io 0.1/0.5A) or 4I + 5U (Io 0.1/0.5A)

2RCA021735

Connector set for REG630 6U half 19" housing

IED including analog input variant

4I + 5U (Io 1/5A), 5I + 4U (Io 0.1/0.5A) or 4I + 5U (Io 0.1/0.5A)

2RCA021736

Connector set for REG630 4U half 19" housing IED including

analog input variant 7I (I0 1/5A) + 3U)2RCA023041

Connector set for REG630 6U half 19" housing IED

including analog input variant 7I (I0 1/5A) + 3U)2RCA023042

Connector set for REG630 4U half 19" housing IED

including analog input variant

8I (I0 1/5A) + 2U or 7I (I0 1/5A) + 1I (I0 0.1/0.5A) + 2U)

2RCA023039

Connector set for REG630 6U half 19" housing IED

including analog input variant

8I (I0 1/5A) + 2U or 7I (I0 1/5A) + 1I (I0 0.1/0.5A) + 2U)

2RCA023040

Mounting accessories for 630 series Order No.

Flush mounting kit for one 4U half 19” housing IED 1KHL400040R0001

Semi-flush mounting kit for one 4U half 19” housing IED 1KHL400444R0001

Wall-mounting kit (cabling towards the mounting wall) for one 4U

half 19” housing IED1KHL400067R0001

Wall-mounting kit (cabling to the front) for one

4U half 19” housing IED1KHL400449R0001

19" rack mounting kit for one 4U half 19” housing IED 1KHL400236R0001

19" rack mounting kit for two 4U half 19” housing IEDs 1KHL400237R0001

Overhead/ceiling mounting kit (with cable space) for one 4U half

19” housing IED1KHL400450R0001

Wall-mounting kit for direct rear wall mounting (with cabling to the

front) of one 6U half 19" housing IED1KHL400452R0001

Wall-mounting kit (with cabling towards the mounting wall) for one

6U half 19" housing IED1KHL400200R0001

Overhead/ceiling mounting kit (with cable space) for one 6U half

19" housing IED1KHL400464R0001

Test switch mounting accessories for 630 series Order No.

19" rack mounting kit for one RTXP8 test switch (the test switch is

not included in the delivery)1KHL400465R0001

19" rack mounting kit for one RTXP18 test switch (the test switch

is not included in the delivery)1KHL400467R0001

19" rack mounting kit for one RTXP24 test switch (the test switch

is not included in the delivery)1KHL400469R0001

Price

EUR

0

0

0

0

0

0

Price

EUR

0

0

0

0

0

0

0

0

0

0

0

Price

EUR

0

0

Page 50: ABBOfflineOrderNumberTool_Ver_15.41b_758059_ENg.xls

REF610Feeder Protection

Selected Order No. REF610C H C N R

Instructions / Order No. Start Pos. 1 8 9 10 11 12 13 14 EUR

Current inputs

Phase current inputs 5 A 5

Phase current inputs 1 A 1

Earth-fault current input 5 A Order No. 8 must be 5 5

Earth-fault current input 1 A Order No. 8 must be 1 1

Power supply

110-240 V AC/110-250 V DC

2xDI (110/125/220/250 VDC), 3xPO, 2xSOH

Scope of the delivery

Complete IED C

Options for REF610

I/O extension module

None N

Communication module

RS-485 R

Language set

(IEC) English, Swedish, Finnish 01

(IEC) English, German, French, Italian, Spanish, Polish 02

(IEC) English, Spanish, Portuguese, French 03

Accessories for REF610 Order No.

Semi-flush mounting kit 1MRS050696

Inclined semi-flush mounting kit 1MRS050831

19” rack mounting kit with cutout for one IED 1MRS050694

19” rack mounting kit with cutout for two IEDs 1MRS050695

Surface mounting frame 1MRS050697

Mounting bracket for 4U high Combiflex equipment frame 1MRS061208

Test switch RTXP 18 for REF610 1MRS050783

Mounting bracket for test switch RTXP 18 1MRS061207

Front communication cable 1MRS050698

0

0

0

Price

EUR

0

0

0

0

0

0

Page 51: ABBOfflineOrderNumberTool_Ver_15.41b_758059_ENg.xls

REM610Motor Protection

Selected Order No. REM610C H C N R

Instructions / Order No. Start Pos. 1 8 9 10 11 12 13 14 EUR

Current inputs

Phase current inputs 5 A 5

Phase current inputs 1 A 1

Earth-fault current input 5 A Order No. 8 must be 5 5

Earth-fault current input 1 A Order No. 8 must be 1 1

Power supply

110-240 V AC/110-250 V DC

2xDI (110/125/220/250 VDC), 3xPO, 2xSOH

Scope of the delivery

Complete IED C

Options for REM610

RTH/Thermistor module

None N

Communication module

RS-485 R R

Language set

(IEC) English, Swedish, Finnish 01

(IEC) English, German, French, Italian, Spanish, Polish 02

(IEC) English, Spanish, Portuguese, French 03

Accessories for REM610 Order No.

Semi-flush mounting kit 1MRS050696

Inclined semi-flush mounting kit 1MRS050831

19” rack mounting kit with cutout for one IED 1MRS050694

19” rack mounting kit with cutout for two IEDs 1MRS050695

Surface mounting frame 1MRS050697

Mounting bracket for 4U high Combiflex equipment frame 1MRS061208

Test switch RTXP 18 for REM610 1MRS050783

Mounting bracket for test switch RTXP 18 1MRS061207

Front communication cable 1MRS050698

0

0

0

0

0

0

Price

EUR

0

0

0

Page 52: ABBOfflineOrderNumberTool_Ver_15.41b_758059_ENg.xls

REU610Voltage Protection

Selected Order No. REU610C V V H C N R

Instructions / Order No. Start Pos. 1 8 9 10 11 12 13 14 EUR

Voltage inputs

Phase -to-phase rated voltages (100/110/115/120V) V

Residual voltage rated voltages (100/110/115/120V) V

Power supply

110-240 V AC/110-250 V DC

2xDI (110/125/220/250 VDC), 3xPO, 2xSOH

Scope of the delivery

Complete IED C

Options for REU610

I/O extension module

None N

Communication module

RS-485 R

Language set

(IEC) English, Swedish, Finnish 01

(IEC) English, German, French, Italian, Spanish, Polish 02

(IEC) English, Spanish, Portuguese, French 03

Price

Accessories for REU610 Order No. EUR

Semi-flush mounting kit 1MRS050696 0

Inclined semi-flush mounting kit 1MRS050831 0

19” rack mounting kit with cutout for one IED 1MRS050694 0

19” rack mounting kit with cutout for two IEDs 1MRS050695 0

Surface mounting frame 1MRS050697 0

Mounting bracket for 4U high Combiflex equipment frame 1MRS061208 0

Test switch RTXP 18 for REU610 1MRS090937 0

Mounting bracket for test switch RTXP 18 1MRS061207 0

Front communication cable 1MRS050698 0

Page 53: ABBOfflineOrderNumberTool_Ver_15.41b_758059_ENg.xls

COM600Station Automation Device

Selected Order No. COM600 N N N D

Instructions / Order No. Start Pos. 1 2 3 4 5 6 7 8 9 10 11 12 EUR

Product family code COM600

Power supply

Power supply110 - 220 V DC, 100 - 240 V AC H

Power supply 24 - 60 VDC L

Optional communication cards (PCI)

Ethernet card (RJ-45) 10Base-T, 100Base-TX,

1000Base-T, 2 portsR

Serial RS-232/RS-485 card, 8 ports S

None N

HMI

Web HMI application (display unit not included) H

FDIR (fault detection, fault isolation and load restroation) including an FDIR-

adapted Web HMIF

None N

Master protocols

One master protocol 1

Two master protocols 2

Three master protocols 3

Slave protocols

One slave protocol 1

Two slave protocols 2

None N

Optional software

Data historian Web HMI required T

Logic processor L

Data historian and Logic processor Web HMI required P

None N

Optional IEC 67850 functionality

IEC 61850 proxy server and GOOSE send enabledSlave protocol required

Order No. 5 = 1 or 2P

No optional IEC 61850 functionality N

GOOSE Analyzer

GOOSE Analyzer enabled G

No GOOSE Analyzer N

Vacant digit

None N

Vacant digit

None N

Vacant digit

None N

Version

Version 4.0 D

Page 54: ABBOfflineOrderNumberTool_Ver_15.41b_758059_ENg.xls

PCM600Programing Tool

Price

Item Order No. Description EUR

PCM600-26 PCM600-26

PCM600 version 2.6 is a configuration, engineering, parameter setting, disturbance handling

and monitoring tool for Relion® products and other Distribution Automation IEDs. PCM600-

26 is FREE OF CHARGE when ordered as own line item in an order of DA products. When

ordered separately with an own Purchase Order number a handling fee of 60 EUR will be

charged for each order.

0

Page 55: ABBOfflineOrderNumberTool_Ver_15.41b_758059_ENg.xls

PML630Load Shedding Controller

Selected Order No. U B P L AA A A Z X C

Instructions / Order No. Pos. 1 2 3 4 5/6 7/8 9 10 11 12 13 14 15 16 17 18 EUR

IED

PML630, 4U half 19" housing & connector set U

Standard

IEC B

Main application

Power Management P

Functional Application

Load Shedding L

Analog Inputs/Outputs

AA = 4I + 5U (Io 1/5A) AA

AB = 8I + 2U (Io 1/5A) AB

Binary I/O

14BI + 9BO AA

Communication (Serial)

Serial glass fibre (ST connector) A

Communication (Ethernet)

Ethernet 100Base-FX (LC connector) A

Ethernet 100Base-TX (RJ-45 connector) B

Communication protocol

IEC 61850 A

Language

English Z

Front Panel

Integrated LHMI A

Detached LHMI, 5 m cable F

Option 1

cPMS: Configuration A A

cPMS: Configuration B (Configuration A + peer-to-peer communication and functionality handling) B

Option 2

No Configurations N

RIO Integration support A

Power supply

48...125 V DC A A

110...250 V DC, 100...240 V AC B

Vacant digit

Vacant X

Version

Version 1.2 C

Page 56: ABBOfflineOrderNumberTool_Ver_15.41b_758059_ENg.xls

RIO600Remote I/O Unit

Price

Item Order No. Description EUR

MOD600ADOM4R MOD600ADOM4R Digital output module with 4 outputs 0

MOD600APSMH07 MOD600APSMH07 High Power supply module 0

MOD600APSML07 MOD600APSML07 Low Power supply module 0

MOD600DLECMIR MOD600DLECMIR Communication module with RJ-45 port 0

MOD600ADIM8H MOD600ADIM8H Digital input module with 8 inputs high power supply 0

MOD600ADIM8L MOD600ADIM8L Digital input module with 8 inputs low power supply 0

MOD600ARTD4 MOD600ARTD4 RTD/mA-input module 0

MOD600AAOM4 MOD600AAOM4 Analogue output module 0

Page 57: ABBOfflineOrderNumberTool_Ver_15.41b_758059_ENg.xls

REC601Wireless Controller

Selected Order No. REC601 C 1 A A A G 1 A Valid

Instructions / Order No. Start Pos. 1 7 8 9 10 11 12 13 14 EUR

Product

Wireless Controller REC601 REC601

Version

1.2 C

Power Supply

85-200 VDC, 90-264 VAC with battery charger (24 VDC) 1

Inputs and Outputs

5 BI + 6 BO, 3CT (0-10 A/0-15 A/4-20mA) + 1 VT (0-30 VAC) A

Communication Interface

Ethernet 10/100BaseT (RJ45) + RS232 + selectable RS232/422/485 A

Communication Protocols

IEC 60870-5-101 + IEC 60870-5-104 A

Wireless Communication Standards

GPRS (+ CSD (GSM Data)) G

Configuration Software Language

English 1

Additional Components

Stub antenna + NTC sensor cable + DIN rail mounting kit A

REC603Wireless Controller

Selected Order No. REC603 C 1 A A A G 1 A Valid

Instructions / Order No. Start Pos. 1 7 8 9 10 11 12 13 14 EUR

Product

Wireless Controller REC603 REC603

Version

1.2 C

Power Supply

85-200 VDC, 90-264 VAC with battery charger (24 VDC) 1

Inputs and Outputs

15 BI + 10 BO, 3CT (0-10 A/0-15 A/4-20mA) + 1 VT (0-30 VAC) A

Communication Interface

Ethernet 10/100BaseT (RJ45) + RS232 + selectableRS232/422/485 A

Communication Protocols

IEC 60870-5-101 + IEC 60870-5-104 A

Wireless Communication Standards

GPRS (+ CSD (GSM Data)) G

Configuration Software Language

English 1

Additional Components

Stub antenna + NTC sensor cable + DIN rail mounting kit A

Price

Accessories Order No. EUR

Hall-effect current transducer 2RCA028227 0

Test load resistor 2RCA028171 0

Null-modem cable 2RCA027558 0

Roof antenna with 150cm cable 2RCA028207 0

Price

Supporting Products Order No. EUR

M2M Gateway 2RCA028228 0

M2M Gateway Enterprise Edition 2RCA028229 0

Page 58: ABBOfflineOrderNumberTool_Ver_15.41b_758059_ENg.xls

RER601Wireless Gateway

Selected Order No. RER601 C 1 N A A G 1 A Valid

Instructions / Order No. Start Pos. 1 7 8 9 10 11 12 13 14 EUR

Product

Wireless Gateway RER601 RER601

Version

1.2 C

Power Supply

6 – 26 VDC 1

Inputs and Outputs

None N

Communication Interface

Ethernet 10/100BaseT (RJ45) + RS232 + selectableRS232/422/485 A

Communication Protocols

IEC 60870-5-101 + IEC 60870-5-104 A

Wireless Communication Standards

GPRS (+ CSD (GSM Data)) G

Configuration Software Language

English 1

Additional Components

Stub antenna + DIN rail mounting kit A

RER603Wireless Gateway

Selected Order No. RER603 C 1 A A A G 1 A Valid

Instructions / Order No. Start Pos. 1 7 8 9 10 11 12 13 14 EUR

Product

Wireless Gateway RER603 RER603

Version

1.2 C

Power Supply

6 – 26 VDC 1

Inputs and Outputs

8 BI + 2 BO A

Communication Interface

Ethernet 10/100BaseT (RJ45) + RS232 + selectableRS232/422/485 A

Communication Protocols

IEC 60870-5-101 + IEC 60870-5-104 A

Wireless Communication Standards

GPRS (+ CSD (GSM Data)) G

Configuration Software Language

English 1

Additional Components

Stub antenna + DIN rail mounting kit A

Price

Accessories Order No. EUR

Null-modem cable (double cable set) 2RCA027811P0001 0

Roof antenna with 150cm cable 2RCA028207 0

Price

Supporting Products Order No. EUR

M2M Gateway 2RCA028228 0

M2M Gateway Enterprise Edition 2RCA028229 0

Page 59: ABBOfflineOrderNumberTool_Ver_15.41b_758059_ENg.xls

RTU

Remote Terminal Unit

Price

Item Order No. Description EUR

560CMD11 R0001 1KGT023400R0001 560CMD11, 24 VDC 0

560CIG10 R0001 1KGT021600R0001 560CIG10 Base Module 0

560CIG10 R0002 1KGT021600R0002 560CIG10 Base Module 0

560CID11 R001 1KGT030400R0001 DIN rail mounted base module 0

560CID11 R002 1KGT030400R0002 DIN rail mounted base module 0

560PSU40 R0001 1KGT011600R0001 DIN rail Power supply unit for 110..220 VDC, 230 VAC 0

560PSU41 R0001 1KGT017700R0001 DIN rail Power supply unit for 24..60 VDC 0

23VG23 R0001 1KGT005500R0001 Mains Adapter 230/115 VAC -> 24 VDC, 48 W 0

23VG24 R0001 1KGT005600R0001 Mains Adapter 230/115 VAC -> 24 VDC, 240 W 0

211BID51 R0001 1KGT024100R0001 211BID51 R0001: 16 binary inputs, 24-60 VDC 0

211BID51 R0002 1KGT024100R0002 211BID51 R0002: 16 binary inputs, 110/125 VDC 0

211BOD52 R0002 1KGT024200R0002 211BOD52 R0002: 8 binary outputs, relays 0

211AID50 R0001 1KGT024000R0001 211AID50 R0001: 6 analogue inputs, mA signals 0

211AID50 R0002 1KGT024000R0002 211AID50 R0002: 6 analogue inputs, V signals 0

560CVD03 R0031 1KGT028000R0031 560CVD03 Transducer, LO, Disp., 1A 0

560CVD03 R0035 1KGT028000R0035 560CVD03 Transducer, LO, Disp., 5A 0

560CVD03 R0051 1KGT028000R0051 560CVD03 Transducer, HI, Disp., 1A 0

560CVD03 R0055 1KGT028000R0055 560CVD03 Transducer, HI, Disp., 5A 0

560CVD11 R0021 1KGT030000R0021 560CVD11 Transducer, FCD, LO, 1A 0

560CVD11 R0025 1KGT030000R0025 560CVD11 Transducer, FCD, LO, 5A 0

560CVD11 R0041 1KGT030000R0041 560CVD11 Transducer, FCD, HI, 1A 0

560CVD11 R0045 1KGT030000R0045 560CVD11 Transducer, FCD, HI, 5A 0

560KCA01 R0001 1KGT030800R0001 Configuration Kit for 560CVDxx 0

211ADD52 R0001 1KGT023900R0001 211ADD52 IO Adapter Board 0

Basic license 50 DP 1KGT201446R0001 Basic License 0

Basic license 250 DP 1KGT201443R0001 Basic License 0

Basic license 750 DP 1KGT201440R0001 Basic License 0

PLC/Archives license 50 DP 1KGT201447R0001 PLC/Archives License 0

PLC/Archives license 250 DP 1KGT201444R0001 PLC/Archives License 0

PLC/Archives license 750 DP 1KGT201441R0001 PLC/Archives License 0

RTUtil560 1KGT210203R0001 Software Package Utilities RTU560 0

MULTIPROGwt 1KGT210204R0001 Software Package Utilities RTU560 for PLC 0

560CMG10 R0001 1KGT017600R0001 560CMG10 Base Module 0

23BE40 R0011 1KGT011100R0011 Binary Input, 16 ch. 110 VDC / 125 VDC #N/A

23BE40 R0012 1KGT011100R0012 Binary Input, 16 ch. 220 VDC / 250 VDC #N/A

23BE50 R0001 1KGT020900R0001 Binary Input, 64 ch., LED's #N/A

23BA40 R0011 1KGT011200R0011 Command Output module 110/220 VDC #N/A

560FOC40 R0001 1KGT011500R0001 RTU560 Optical Coupler (24 VDC) 0

560CVD03 R0021 1KGT028000R0021 560CVD03 Transducer, LO, 1A, 3U3I 0

560CVD03 R0025 1KGT028000R0025 560CVD03 Transducer, LO, 5A, 3U3I 0

560CVD03 R0041 1KGT028000R0041 560CVD03 Transducer, HI, 1A, 3U3I 0

560CVD03 R0045 1KGT028000R0045 560CVD03 Transducer, HI, 5A, 3U3I 0

Basic license 5000 DP 1KGT201437R0001 Basic License 0

PLC/Archives license 5000 DP 1KGT201438R0001 PLC/Archives License 0

HMI license 50 DP 1KGT201448R0001 HMI License 0

HMI license 250 DP 1KGT201445R0001 HMI License 0

HMI license 750 DP 1KGT201442R0001 HMI License 0

HMI license 5000 DP 1KGT201439R0001 HMI License 0

RTUtil61850 1KGT210238R0001 RTUtil61850 system configuration tool #N/A

Page 60: ABBOfflineOrderNumberTool_Ver_15.41b_758059_ENg.xls

RTU

Remote Terminal Unit

Page 61: ABBOfflineOrderNumberTool_Ver_15.41b_758059_ENg.xls

REF541, REF 543, REF 545Feeder Terminal

Selected Order No. REF54 K A

Instructions / Order No. Start Pos. 1 6 7 8 9 12 13 14 15 16 EUR

Analog inputs and Binary inputs/outputs and RTD options

4 x I (1/5 A) + 1 x I (0,2/1 A) + 4 x U (100 V)

15 BI + 14 BO 1 115

4 x I (1/5 A) + 1 x I (0,2/1 A) + 4 x U (100 V)

15 BI + 14 BO + 8 RTD/analogue inputs + 4 analogue outputs1 118

4 x I (1/5 A) + 1 x I (0,2/1 A) + 4 x U (100 V)

25 BI + 20 BO3 127

4 x I (1/5 A) + 1 x I (0,2/1 A) + 4 x U (100 V)

25 BI + 20 BO + 8 RTD/analogue inputs + 4 analogue outputs3 129

4 x I (1/5 A) + 1 x I (0,2/1 A) + 4 x U (100 V)

34 BI + 28 BO5 133

Software revision

Current revision K

Functionality level

C = Control C

B = Basic B

M = Multi M

Power supply

A = Medium

power supply: Ur = 110/120/220/240 V ac; 110/125/220 V dc

digital inputs: Ur = 110/125/220 V dc

threshold voltage: Ut = 80 V dc

A

B = High

power supply: Ur = 110/120/220/240 V ac; 110/125/220 V dc

digital inputs: Ur = 220 V dc

threshold voltage: Ut = 155 V dc

B

C = Low

power supply: Ur = 24/48/60 V dc

digital inputs: Ur = 24/48/60/110/125/220 V dc

threshold voltage: Ut = 18 V dc

C

Reserved digit

Reserved for future use A

Sensor inputs

A = without sensor input A

B = 9 sensor channels (current or voltage) B

Display mounting option

A = fixed display A

B = external disply moduleNot possible combination

Order No. 12 = CB

Language options

English-German 001

English-Swedish 002

English-Finnish 003

English - Portuguese 007

English - Polish 008

English - Russian 009

English - Spanish 010

English - Czech 012

Optional functionality to be ordered together with the IED

Price

Capacitor bank protection Order No. EUR

Optional SW for REF541/543/545 Capasitor bank overload protection for

REF 541/543/545 control, basic and multi. (OL3CAP)1MRS100116 0

Page 62: ABBOfflineOrderNumberTool_Ver_15.41b_758059_ENg.xls

REF541, REF 543, REF 545Feeder Terminal

Selected Order No. REF54 K A

Instructions / Order No. Start Pos. 1 6 7 8 9 12 13 14 15 16 EUR

Optional SW for REF541/543/545 Capasitor bank current unbalance

protection for REF 541/543/545 control, basic and multi. (CUB1CAP)1MRS100117 0

Optional SW for REF541/543/545 Capasitor bank protection, protection

against internal faults in H-bridge connected banks for REF 541/543/545

control, basic and multi. (CUB3CAP)

1MRS100052 0

Capacitor bank control

Optional SW for REF 541/543/545 and for REC 523. Power Factor

Controller. (COPFC)1MRS100143 0

Power quality

Optional SW for REF 541/543/545 and for REC 523. Current Waveform

Distortion Measurement. (PQCU3H)1MRS100512 0

Optional SW for REF 541/543/545 and for REC 523. Voltage Waveform

Distortion Measurement. (PQVO3H)1MRS100513 0

Optional SW for REF541/543/545 Power Quality, Sags and Swells

(PQVO3Sd)1MRS100514 0

Fault locator

Optional SW for REF541/543/545 Fault Locator (FLOC) 1MRS100058 0

Page 63: ABBOfflineOrderNumberTool_Ver_15.41b_758059_ENg.xls

REM 543, REM 545Machine Terminal

Selected Order No. REM54 B A

Instructions / Order No. Start Pos. 1 6 7 8 9 12 13 14 15 16 EUR

REM543 Analog inputs and Binary inputs/outputs and RTD options

4 x I (1/5 A) + 1 x I (0,2/1 A) + 4 x U (100 V)

15 BI + 14 BO 3 212

4 x I (1/5 A) + 1 x I (0,2/1 A) + 4 x U (100 V)

15 BI + 14 BO + 8 RTD/analogue inputs + 4 analogue outputs3 213

6 x I (1/5 A) + 3 x U (100 V)

15 BI + 14 BO3 214

6 x I (1/5 A) + 3 x U (100 V)

15 BI + 14 BO + 8 RTD/analogue inputs + 4 analogue outputs3 215

7 x I (1/5 A) + 2 x U (100 V)

15 BI + 14 BO3 216

7 x I (1/5 A) + 2 x U (100 V)

15 BI + 14 BO + 8 RTD/analogue inputs + 4 analogue outputs3 217

8 x I (1/5 A) + 1 x U (100 V)

15 BI + 14 BO3 218

8 x I (1/5 A) + 1 x U (100 V)

15 BI + 14 BO + 8 RTD/analogue inputs + 4 analogue outputs3 219

REM545 Analog inputs and Binary inputs/outputs and RTD options

4 x I (1/5 A) + 1 x I (0,2/1 A) + 4 x U (100 V)

25 BI + 20 BO 5 222

4 x I (1/5 A) + 1 x I (0,2/1 A) + 4 x U (100 V)

25 BI + 20 BO + 8 RTD/analogue inputs + 4 analogue outputs5 223

6 x I (1/5 A) + 3 x U (100 V)

25 BI + 20 BO5 224

6 x I (1/5 A) + 3 x U (100 V)

25 BI + 20 BO + 8 RTD/analogue inputs + 4 analogue outputs5 225

7 x I (1/5 A) + 2 x U (100 V)

25 BI + 20 BO5 226

7 x I (1/5 A) + 2 x U (100 V)

25 BI + 20 BO + 8 RTD/analogue inputs + 4 analogue outputs5 227

8 x I (1/5 A) + 1 x U (100 V)

25 BI + 20 BO5 228

8 x I (1/5 A) + 1 x U (100 V)

25 BI + 20 BO + 8 RTD/analogue inputs + 4 analogue outputs5 229

Software revision

Current revision Will be filled automatically B

Functionality level

M = Motor M

G = Generator G

Power supply

A = Medium

power supply: Ur = 110/120/220/240 V ac; 110/125/220 V dc

digital inputs: Ur = 110/125/220 V dc

threshold voltage: Ut = 80 V dc

A

B = High

power supply: Ur = 110/120/220/240 V ac; 110/125/220 V dc

digital inputs: Ur = 220 V dc

threshold voltage: Ut = 155 V dc

Not possible with combinations

Order No. 9 = 218 or 219 or 228

or 229

B

C = Low

power supply: Ur = 24/48/60 V dc

digital inputs: Ur = 24/48/60/110/125/220 V dc

threshold voltage: Ut = 18 V dc

C

Reserved digit

Reserved for future use A

Sensor inputs

A = without sensor input A

B = 9 sensor channels (current or voltage)Not possible with combination

Order No. 12 = BB

Page 64: ABBOfflineOrderNumberTool_Ver_15.41b_758059_ENg.xls

REM 543, REM 545Machine Terminal

Selected Order No. REM54 B A

Instructions / Order No. Start Pos. 1 6 7 8 9 12 13 14 15 16 EUR

Display mounting option

A = fixed display A

B = external disply moduleNot possible with combination

Order No. 12 = B or CB

Language options

English-German 001

English-Swedish 002

English-Finnish 003

English-Russian 009

Current injection device for earth-fault protection of a

synchronous machine rotor

Price

Description Order No. EUR

Electronic device for rotor earth fault detection in the

excitation circuit of synchronous machine.REK 510-AA 0

Page 65: ABBOfflineOrderNumberTool_Ver_15.41b_758059_ENg.xls

RET 541, RET 543, RET 545Transformer Terminal

Selected Order No. RET54 A A A

Instructions / Order No. Pos. 1 6 7 8 9 12 13 14 15 16 EUR

RET541 Analog inputs and Binary inputs/outputs and RTD options

6 x I (1/5 A) + 3 x U (100 V)

15 BI + 14 BO1 230

6 x I (1/5 A) + 3 x U (100 V)

15 BI + 14 BO + 8 RTD/analogue inputs + 4 analogue outputs1 233

7 x I (1/5 A) + 2 x U (100 V)

15 BI + 14 BO

Only for functionality levels

Basic and Multi, Order No. 8 = B or M1 231

7 x I (1/5 A) + 2 x U (100 V)

15 BI + 14 BO + 8 RTD/analogue inputs + 4 analogue outputs

Only for functionality levels

Basic and Multi, Order No. 8 = B or M1 234

8 x I (1/5 A) + 1 x U (100 V)

15 BI + 14 BO

Only for functionality levels

Basic and Multi, Order No. 8 = B or M1 232

8 x I (1/5 A) + 1 x U (100 V)

15 BI + 14 BO + 8 RTD/analogue inputs + 4 analogue outputs

Only for functionality levels

Basic and Multi, Order No. 8 = B or M1 235

RET543 Analog inputs and Binary inputs/outputs and RTD options

6 x I (1/5 A) + 3 x U (100 V)

25 BI + 20 BO3 240

6 x I (1/5 A) + 3 x U (100 V)

25 BI + 20 BO + 8 RTD/analogue inputs + 4 analogue outputs3 243

7 x I (1/5 A) + 2 x U (100 V)

25 BI + 20 BO

Only for functionality levels

Basic and Multi, Order No. 8 = B or M3 241

7 x I (1/5 A) + 2 x U (100 V)

25 BI + 20 BO + 8 RTD/analogue inputs + 4 analogue outputs

Only for functionality levels

Basic and Multi, Order No. 8 = B or M3 244

8 x I (1/5 A) + 1 x U (100 V)

25 BI + 20 BO

Only for functionality levels

Basic and Multi, Order No. 8 = B or M3 242

8 x I (1/5 A) + 1 x U (100 V)

25 BI + 20 BO + 8 RTD/analogue inputs + 4 analogue outputs

Only for functionality levels

Basic and Multi, Order No. 8 = B or M3 245

RET545 Analog inputs and Binary inputs/outputs

6 x I (1/5 A) + 3 x U (100 V)

34 BI + 28 BO5 250

7 x I (1/5 A) + 2 x U (100 V)

34 BI + 28 BO

Only for functionality levels

Basic and Multi, Order No. 8 = B or M5 251

8 x I (1/5 A) + 1 x U (100 V)

30 BI + 28 BO

Only for functionality levels

Basic and Multi, Order No. 8 = B or M5 252

Software revision

Current revision A

Functionality level

C = Control C

B = Basic B

M = Multi M

Power supply

A = Medium

power supply: Ur = 110/120/220/240 V ac; 110/125/220 V dc

digital inputs: Ur = 110/125/220 V dc

threshold voltage: Ut = 80 V dc

A

B = High

power supply: Ur = 110/120/220/240 V ac; 110/125/220 V dc

digital inputs: Ur = 220 V dc

threshold voltage: Ut = 155 V dc

B

C = Low

power supply: Ur = 24/48/60 V dc

digital inputs: Ur = 24/48/60/110/125/220 V dc

threshold voltage: Ut = 18 V dc

C

Reserved digit

Reserved for future use A

Reserved digit

Reserved for future use A

Page 66: ABBOfflineOrderNumberTool_Ver_15.41b_758059_ENg.xls

RET 541, RET 543, RET 545Transformer Terminal

Selected Order No. RET54 A A A

Instructions / Order No. Pos. 1 6 7 8 9 12 13 14 15 16 EUR

Display mounting option

A = fixed display A

B = external disply moduleNot possible combination

digit 12 = CB

Language options

English-German 001

English-Swedish 002

English-Finnish 003

English-Portuguese 007

English-Polish 008

English-Russian 009

English-Spanish 010

Optional functionality to be ordered together with the IEDPrice

Description Order No. EUR

Tap Changer control function (COLTC)

The COLTC Tap Changer control function block comes as

standard in the Control version. In the Basic and the

Multi versions, COLTC is available as an option.

1MRS100144 0

Page 67: ABBOfflineOrderNumberTool_Ver_15.41b_758059_ENg.xls

REF542plusFeeder Terminal

Selected Order No. 7 6

Instructions / Order No. Pos. 1 2 3 4 5 6 7 8 9/10 11 12 13 14 15 EUR

Family code

REF542plus 7

Application area

REF542plus for normal operation

For special applications like marine, offshore and for motor protection

in explosive area please see in CCP or contact ABB sales office.

6

Main board version

Basic - Version with RJ 45 Ethernet port A

Standard - Version basic with additional IRIG B E

Full - Version standard with additional optical links C

Power supply versions

Un = 110 V DC - Operative range 70% to 120% of 110 V DC 1

Un = 220 V DC - Operative range 70% to 120% of 220 V DC 2

Un = 48 V DC to 220 V DC - Operative range 80% of 48 V DC to

120% of 220 V DC3

Un = 48 V DC to - 220 V DC -A varnished version 6

Analog I/O modules

No analog input or output - Empty analog I/O module slot N

Analog input module 4 - 20 mA installed - up to 6 inputs A

Analog output module for 0(4) - 20 mA installed - up to 4 outputs B

Binary I/O modules

Static I/O

Application in GIS panel with coil supervision by control continuity check

If Order No. 6 = 1 or 2, Order No. 7 and 8

can be only 1 or 2 or N1 1 1

Static I/O

Static I/O without control continuity check

If Order No. 6 = 1 or 2, Order No. 7 and 8

can be only 1 or 2 or N2 2 2

Static I/O with TSCIf Order No. 6 = H, Order No. 7 and 8 can be only

H or NH H H

Binary I/O3 - 19-72 V/14 V DC, standard

Standard version with 14 V DC treshold value for application in auxiliary circuit

with DC voltage range 19-72 V DC

If Order No. 6 = 5, 6, 7 or 8,

Order No. 7 and 8 can be only 5, 6, 7, 8 or N5 5 5

Binary I/O3 - 19-72 V/14 V DC, with static channel

As no. 5 + one static output channel for energy metering

If Order No. 6 = 5, 6, 7 or 8,

Order No. 7 and 8 can be only 5, 6, 7, 8 or N6 6 6

Binary I/O3 - 19-72 V/14 V DC, interconnected input, standard

As no. 5 + interconnected binary inputs

If Order No. 6 = 5, 6, 7 or 8,

Order No. 7 and 8 can be only 5, 6, 7, 8 or N7 7 7

Binary I/O3 - 19-72 V/14 V DC, interconnected input, with static channel

As no. 5 + interconnected binary inputs + one static output channel for

energy metering

If Order No. 6 = 5, 6, 7 or 8,

Order No. 7 and 8 can be only 5, 6, 7, 8 or N8 8 8

Binary I/O3 - 88-132 V/50 V DC, standard

Standard version with 50 V DC treshold value for application in auxiliary circuit

with DC voltage range 88 - 132 V DC

If Order No. 6 = 9, A, B or C

Order No. 7 and 8 can be only 9, A, B, C or N9 9 9

Binary I/O3 - 88-132 V/50 V DC, with static channel

As no.9 + one static output channel for energy metering

If Order No. 6 = 9, A, B or C

Order No. 7 and 8 can be only 9, A, B, C or NA A A

Binary I/O3 - 88-132 V/50 V DC, interconnected input, standard

As no. 9 + interconnected binary inputs

If Order No. 6 = 9, A, B or C

Order No. 7 and 8 can be only 9, A, B, C or NB B B

Binary I/O3 - 88-132 V/50 V DC, interconnected input, with static channel

As no. 9 + interconnected binary inputs + one static output channel for

energy metering

If Order No. 6 = 9, A, B or C

Order No. 7 and 8 can be only 9, A, B, C or NC C C

Binary I/O3 - 88-132 V/72 V DC, standard

Standard version with 143 V DC treshold value for application in auxiliary circuit

with DC voltage range 154 - 264 V DC

If Order No. 6 = D or E

Order No. 7 and 8 can be only D, E or ND D D

Binary I/O3 - 88-132 V/72 V DC, with static channel

As no.D + one static output channel for energy metering

If Order No. 6 = D or E

Order No. 7 and 8 can be only D, E or NE E E

Binary I/O3 - 176-264 V/143 V DC, standard

Standard version with 72 V DC treshold value for application in auxiliary circuit

with DC voltage range 88 - 132 V DC

If Order No. 6 = F or G

Order No. 7 and 8 can be only F, G or NF F F

Binary I/O3 - 176-264 V/143 V DC, with static channel

As no.F + one static output channel for energy metering

If Order No. 6 = F or G

Order No. 7 and 8 can be only F, G or NG G G

No Binary I/O module in slot 3 N

No binary I/O module in slots 2 and 3 N N

Analog input modules

Sensors

Analog input sensors version 01

Mix of sensors and transformers

3 sensors + 3 sensors + 1 CT/0.2 A + 1 VT 10

3 sensors + 3 VT + 1 CT/0.2 A + 1 VT 11

3 sensors + 3 sensors + 1 CT 12

3 sensors + 3 sensors + 1 CT+ 1 VT 13

3 sensors + 3 sensors + 1 CT/0.2 A 14

3 sensors + 3 sensors + 1 VT + 1 VT 15

Page 68: ABBOfflineOrderNumberTool_Ver_15.41b_758059_ENg.xls

REF542plusFeeder Terminal

Selected Order No. 7 6

Instructions / Order No. Pos. 1 2 3 4 5 6 7 8 9/10 11 12 13 14 15 EUR

3 sensors + 3 CT + 1 CT/0.2 A + 1 VT 16

3 sensors + 3 CT + 1 CT/0.2 A + 1 CT/0.2 A 17

Mix of transformers

3 CT + 3 VT + 1 CT/0.2 A + 1 VT 30

3 VT + 3 VT + 1 CT/0.2 A + 1 CT/0.2 A 31

3 CT + 3 CT 32

3 CT + 3 CT + 1 CT/0.2 A+ 1 VT 33

3 VT + 3 VT + 1 VT 34

3 CT + 3 VT + 1 CT 35

3 CT + 3 VT + 1 CT + 1 VT 36

3 CT + 0 VT + 1 CT 37

3 CT + 0 VT + 1 CT/0.2 A 38

3 CT + 3 VT + 1 CT/0.2 A + 1 CT/0.2 A 39

3 CT + 3 VT + 1 VT + 1 VT 40

3 CT + 3 CT + 1 CT + 1 CT 41

3 CT + 3 CT + 1 CT + 1 VT 42

3 CT + 3 VT + 1 CT + 1 CT 43

Communication module

IED without communication (communication module) N

Modbus RTU / SPA RS 485

To be used for Modbus RTU or for SPA protocol1

Modbus RTU / SPA glass fibre with ST connectors

To be used for Modbus RTU or for SPA protocol2

SPA plastic fibre with HFBR 4503 connectors

To be used for Modbus SPA protocol3

SPA glass fibre with SMA connectors 4

SPA glass fibre with ST connectors

To be used for Modbus SPA protocol5

LON-LAG 1.4

To be used for ABB LON per lag 1.4 protocol6

IEC 60870-5-103 with ST connectors

To be used for IEC 60870-5-103 protocol7

IEC 61850 / MODBUS TCP with RJ45

To be used for IEC 61850-8-1 and MODBUS TCP protocolE

IEC 61850 / MODBUS TCP with LC optical connector

To be used for IEC 61850-8-1 and MODBUS TCP protocolF

Enclosure versions

Normal base unit S

Wide base unit W

HMI variants

No HMI N N

HMI V5 - IEC, Operative range 48 V DC to 240 V DC

(Direct replacement for A & B) with Unicode fontsS

HMI V5 - IEC, external cover Operative range 48 V DC to 240 V DC

(Direct replacement for C & D)T

Connection cables between the HMI and the base unit

No cable N

HMI cable - 2.5 m 2

HMI cable - 3.5 m 3

HMI cable - 4.5 m 4

Software functionality level

Software level : Base 1

Software level : Basic Low 3

Software level : Basic 4

Software level : Multi Low 5

Software level : Multi 6

Software level : Differential 7

Software level : Distance 8

Accessories for REF542plus Order No.

Connector kit - SET 1 (with metal cover) 1VCF750142821

Connector kit - SET 2 1VCF750142820

I-Button (protection) 1VCF750193801

I-Button (control) 1VCF750193802 0

Price

EUR

0

0

0

Page 69: ABBOfflineOrderNumberTool_Ver_15.41b_758059_ENg.xls

REF542plusFeeder Terminal

Selected Order No. 7 6

Instructions / Order No. Pos. 1 2 3 4 5 6 7 8 9/10 11 12 13 14 15 EUR

Programming cable for MMI2 1MRS050942

REF542plus Operating Tool CD 1MRS151022

REF542plus Configur Tool CD 1MRS151062

Hand Tool Crimper for Binary I/O crimp contacts 1YHT500001810

Hand Tool Crimper for Analog Input crimp contacts 1YHT500001811

Extraction Tool for Binary I/O crimp contacts 1MRS123009

Extraction Tool for Analog Input crimp contacts 1MRS123010 0

0

0

0

0

0

0

Page 70: ABBOfflineOrderNumberTool_Ver_15.41b_758059_ENg.xls

REA 101Arc Protection IED with extension units and accessories

Price

Item Order No. Description EUR

REA101-AAA REA 101-AAAArc Protection 50-60 Hz, 110-240 V AC 110-250 V DC Central unit with optolink connectors for

plastic fiber. Includes mounting kit 1MRS050209 for flush mounting0

REA101-AAAG REA 101-AAAGArc Protection 50-60 Hz, 110-240 V AC, 110-250 V DC Central unit with optolink connectors for

glass fibre. Includes mounting kit 1MRS050209 for flush mounting0

REA101-CAA REA 101-CAAArc Protection 24-60 V DC Central unit with optolink connectors for plastic fiber.

Includes mounting kit 1MRS050209 for flush mounting0

REA101-CAAG REA 101-CAAGArc Protection 24-60 V DC Central unit with optolink connectors for glass fiber.

Includes mounting kit 1MRS050209 for flush mounting0

REA103-AA REA103-AA Arc protection system (Relays, module) Arc protection extension units 0

REA105-AA REA105-AA Arc protection system (Relays, module) Tripping extension unit 0

REA107-AA REA 107-AA Arc protection system (Relays, module) Extension unit for lens type sensors. 0

Mounting accessories for REA 101

1MRS060196 1MRS060196 Rear plate protective cover 0

1MRS050254 1MRS050254 Mounting kit for semi-flush mounting 0

1MRS050240 1MRS050240 Mounting kit for surface mounting 0

1MRS050241 1MRS050241 Mounting kit for connecting cases together 0

1MRS050258 1MRS050258 Mounting kit for 19” rack 0

Cables for connecting REA 101 to an extension unit, or the extension units to each other

1MRS120511.001 1MRS120511.001Cables for serial interface connection Connection cable with RJ-45 connectors between main unit

REA 101 and extension units REA 103/105/107, length 1 m0

1MRS120511.003 1MRS120511.003Cables for serial interface connection Connection cable with RJ-45 connectors between main unit

REA 101 and extension units REA 103/105/107, length 3 m0

1MRS120511.005 1MRS120511.005Cables for serial interface connection Connection cable with RJ-45 connectors between main unit

REA 101 and extension units REA 103/105/107, length 5 m0

1MRS120511.010 1MRS120511.010Cables for serial interface connection Connection cable with RJ-45 connectors between main unit

REA 101 and extension units REA 103/105/107, length 10 m0

1MRS120511.015 1MRS120511.015Cables for serial interface connection Connection cable with RJ-45 connectors between main unit

REA 101 and extension units REA 103/105/107, length 15 m0

1MRS120511.020 1MRS120511.020Cables for serial interface connection Connection cable with RJ-45 connectors between main unit

REA 101 and extension units REA 103/105/107, length 20 m0

1MRS120511.030 1MRS120511.030Cables for serial interface connection 30 m +/- 3% Connection cable with RJ-45 connectors between

main unit REA 101 and extension units REA 103/105/107, length 30 m0

1MRS120511.040 1MRS120511.040Cables for serial interface connection Connection cable with RJ-45 connectors between main unit

REA 101 and extension units REA 103/105/107, length 40 m0

Plastic fiber optolink for signal transfer between REA 101 central units

SPA-ZF AA 1 RS 951 007-AA Fibre-optic cables 1 m +/- 3% Plastic signal transfer fibre 0

SPA-ZF AA 10 RS 951 007-DA Fibre-optic cables 10 m +/- 3% Plastic signal transfer fibre 0

SPA-ZF AA 2 RS 951 007-GA Fibre-optic cables 2 m +/- 3% Plastic signal transfer fibre 0

SPA-ZF AA 20 RS 951 007-EA Fibre-optic cables 20 m +/- 3% Plastic signal transfer fibre 0

SPA-ZF AA 3 RS 951 007-BA Fibre-optic cables 3m +/- 3% Plastic signal transfer 0

SPA-ZF AA 30 RS 951 007-FA Fibre-optic cables 30 m +/- 3% Plastic signal transfer fibre 0

SPA-ZF AA 5 RS 951 007-CA Fibre-optic cables 5 m +/- 3% Plastic signal transfer fibre 0

Pre-manufactured fiber sensors

1MRS120512.005 1MRS120512.005 Pre-manufactured sensor fibers for REA, arc protection relay 5 m 0

1MRS120512.010 1MRS120512.010 Pre-manufactured sensor fibers for REA, arc protection relay 10 m 0

1MRS120512.015 1MRS120512.015 Pre-manufactured sensor fibers for REA, arc protection relay 15 m 0

1MRS120512.020 1MRS120512.020 Pre-manufactured sensor fibers for REA, arc protection relay 20 m 0

1MRS120512.025 1MRS120512.025 Pre-manufactured sensor fibers for REA, arc protection relay 25 m 0

1MRS120512.030 1MRS120512.030 Pre-manufactured sensor fibers for REA, arc protection relay 30 m 0

1MRS120512.040 1MRS120512.040 Pre-manufactured sensor fibers for REA, arc protection relay 40 m 0

1MRS120512.050 1MRS120512.050 Pre-manufactured sensor fibers for REA, arc protection relay 50 m 0

1MRS120512.060 1MRS120512.060 Pre-manufactured sensor fibers for REA, arc protection relay 60 m 0

Accessories for manufacturing fiber sensors

Page 71: ABBOfflineOrderNumberTool_Ver_15.41b_758059_ENg.xls

REA 101Arc Protection IED with extension units and accessories

Price

Item Order No. Description EUR

1MSC380018.100 1MSC380018.100 Sensor fiber 100 m 0

1MSC380018.300 1MSC380018.300 Sensor fiber 300 m 0

1MSC380018.500 1MSC380018.500 Sensor fiber 500 m 0

SYJ-ZBC 1A1 SYJ-ZBC 1A1 ST connector 0

SYJ-ZBC 1A2 SYJ-ZBC 1A2 ST splice adapter 0

1MSC990016 1MSC990016 ST fiber termination kit 0

1MRS060743 1MRS060743 Light collecting lens without fiber for Lens type sensor for REA 107 0

1MRS124000 1MRS124000Cable tie package including 100 pieces for fixing sensor cables. The cable tie itself is to be fixed in a

Ø 4,8 mm trough hole drilled in a metal sheet.0

Pre-manufactured lens sensors for REA 107

1MRS120534-1.5 1MRS120534-1.5 Pre-manufactured lens type arc-protection sensor with optical fiber and DNP-connector for REA 107

and REF 610 and REF 615, length 1.5 m0

1MRS120534-3 1MRS120534-3 Pre-manufactured lens type arc-protection sensor with optical fiber and DNP-connector for REA 107

and REF 610 and REF 615, length 3 m0

1MRS120534-5 1MRS120534-5Pre-manufactured lens type arc-protection sensor with optical fiber and DNP-connector for REA 107

and REF 610 and REF 615, length 5 m0

1MRS120534-7 1MRS120534-7Pre-manufactured lens type arc-protection sensor with optical fiber and DNP-connector for REA 107

and REF 610, length 7 m0

1MRS120534-10 1MRS120534-10Pre-manufactured lens type arc-protection sensor with optical fiber and DNP-connector for REA 107

and REF 610, length 10 m0

1MRS120534-15 1MRS120534-15Pre-manufactured lens type arc-protection sensor with optical fiber and DNP-connector for REA 107,

length 15 m0

1MRS120534-20 1MRS120534-20Pre-manufactured lens type arc-protection sensor with optical fiber and DNP-connector for REA 107,

length 20 m0

1MRS120534-25 1MRS120534-25Pre-manufactured lens type arc-protection sensor with optical fiber and DNP-connector for REA 107,

length 25 m0

1MRS120534-30 1MRS120534-30Pre-manufactured lens type arc-protection sensor with optical fiber and DNP-connector for REA 107,

length 30 m0

Pre-manufactured lens sensors for REA 101, REA 103 and REA 105

1MRS120536-2 1MRS120536-2Pre-manufactured lens type arc protection sensor with optical fiber and ST-connector for REA

101/103/105 units, length 2 m0

1MRS120536-3 1MRS120536-3Pre-manufactured lens type arc protection sensor with optical fiber and ST-connector for REA

101/103/105 units, length 3 m0

1MRS120536-5 1MRS120536-5Pre-manufactured lens type arc protection sensor with optical fiber and ST-connector for REA

101/103/105 units, length 5 m0

1MRS120536-10 1MRS120536-10Pre-manufactured lens type arc protection sensor with optical fiber and ST-connector for REA

101/103/105 units, length 10 m0

Page 72: ABBOfflineOrderNumberTool_Ver_15.41b_758059_ENg.xls

SPACOMProtection IED

Price

Item Order No. Description EUR

SPACOM

SPAJ 140 C-AA RS 611 006-AA Overcurrent and earth-fault relay 50 Hz, 80-265 V AC/DC 0

SPAJ 140 C-CA RS 611 006-CA Overcurrent and earth-fault relay 50 Hz, 18-80 V DC 0

SPAJ 140 C-DA RS 611 006-DA Overcurrent and earth-fault relay 60 Hz, 80-265 V AC/DC 0

SPAJ 140 C-FA RS 611 006-FA Overcurrent and earth-fault relay 60 Hz, 18-80 V DC 0

SPAJ 160 C-AA RS 611 051-AA Capacitor protection relay 50 Hz, 80-265 V AC/DC 0

SPAJ 160 C-CA RS 611 051-CA Capacitor protection relay 50 Hz, 18-80 V DC 0

SPAJ 160 C-DA RS 611 051-DA Capacitor protection relay 60 Hz, 80-265 V AC/DC 0

SPAJ 160 C-FA RS 611 051-FA Capacitor protection relay 60 Hz, 18-80 V DC 0

SPAM 150 C-AA RS 641 014-AA

Motor protection relay with: Over and undercurrent protection, earth-fault protection,

thermal overload for motors, phase reversal/unbalance protection, motor start-up

supervision 50 Hz, 80-265 V AC/DC Functionality: Versatile multifunction relay for the

0

SPAM 150 C-AB RS 641 015-AB

Motor protection relay with: Over and undercurrent protection, earth-fault protection,

thermal overload for motors, phase reversal/unbalance protection, motor start-up

supervision 50 Hz, 80-265 V AC/DC Functionality: Versatile multifunction relay for the

0

SPAM 150 C-CA RS 641 014-CA

Motor protection relay with: Over and undercurrent protection, earth-fault protection,

thermal overload for motors, phase reversal/unbalance protection, motor start-up

supervision 50 Hz, 18-80 V DC Functionality: Versatile multifunction relay for the prot

0

SPAM 150 C-CB RS 641 015-CB

Motor protection relay with: Over and undercurrent protection, earth-fault protection,

thermal overload for motors, phase reversal/unbalance protection, motor start-up

supervision 50 Hz, 18-80 V DC Functionality: Versatile multifunction relay for the prot

0

SPAM 150 C-DA RS 641 014-DA

Motor protection relay with: Over and undercurrent protection, earth-fault protection,

thermal overload for motors, phase reversal/unbalance protection, motor start-up

supervision 60 Hz, 80-265 V AC/DC Functionality: Versatile multifunction relay for the

0

SPAM 150 C-DB RS 641 015-DB

Motor protection relay with: Over and undercurrent protection, earth-fault protection,

thermal overload for motors, phase reversal/unbalance protection, motor start-up

supervision 60 Hz, 80-265 V AC/DC Functionality: Versatile multifunction relay for the

0

SPAM 150 C-FA RS 641 014-FA

Motor protection relay with: Over and undercurrent protection, earth-fault protection,

thermal overload for motors, phase reversal/unbalance protection, motor start-up

supervision 60 Hz, 18-80 V DC Functionality: Versatile multifunction relay for the prot

0

SPAM 150 C-FB RS 641 015-FB

Motor protection relay with: Over and undercurrent protection, earth-fault protection,

thermal overload for motors, phase reversal/unbalance protection, motor start-up

supervision 60 Hz, 18-80 V DC Functionality: Versatile multifunction relay for the prot

0

SPER 1B1 C4-AA RS 485 004-AA Supervision relay 40-265 V DC Trip circuit supervision relay 0

SPER 1C1-AA RS 485 002-AA Supervision relay 40-265 V DC Trip circuit supervision relay. 0

SPER 1C2-AA RS 485 003-AA Supervision relay 20 - 60 V DC Trip circuit supervision relay 0

1MRS061021 1MRS061021 Supervision relay Securing clanp for vibration-proof installation of SPER 1B1 C4. 0

PC-ZL 2 RS 961 051-AA Supervision relay Terminal socket for SPER 1B1 C4 0

SPE-ZR 3 RS 961 015-AA Supervision relay Current limiting resistor for SPER 1B1 C4 and SPER 1C1. 0

SPACOM relays with test switch

RS 611 206-AA RS 611 206-AA SPAJ 140 C with test switch: Overcurrent and earth-fault relay 0

RS 611 206-CA RS 611 206-CA SPAJ 140 C with test switch: Overcurrent and earth-fault relay 0

RS 611 206-DA RS 611 206-DA SPAJ 140 C with test switch: Overcurrent and earth-fault relay 0

Page 73: ABBOfflineOrderNumberTool_Ver_15.41b_758059_ENg.xls

SPACOMProtection IED

Price

Item Order No. Description EUR

RS 611 206-FA RS 611 206-FA SPAJ 140 C with test switch: Overcurrent and earth-fault relay 0

RS 611 251-AA RS 611 251-AA SPAJ 160 C with test switch: Capacitor protection relay 0

RS 611 251-CA RS 611 251-CA SPAJ 160 C with test switch: Capacitor protection relay 0

RS 611 251-DA RS 611 251-DA SPAJ 160 C with test switch: Capacitor protection relay 0

RS 611 251-FA RS 611 251-FA SPAJ 160 C with test switch: Capacitor protection relay 0

RS 641 214-AA RS 641 214-AA

SPAM 150 C with test switch: Motor protection relay with: Over and undercurrent

protection, earth-fault protection, thermal overload for motors, phase

reversal/unbalance protection, motor start-up supervision

0

RS 641 215-AB RS 641 215-AB

SPAM 150 C with test switch: Motor protection relay with: Over and undercurrent

protection, earth-fault protection, thermal overload for motors, phase

reversal/unbalance protection, motor start-up supervision

0

RS 641 214-CA RS 641 214-CA

SPAM 150 C with test switch: Motor protection relay with: Over and undercurrent

protection, earth-fault protection, thermal overload for motors, phase

reversal/unbalance protection, motor start-up supervision

0

RS 641 215-CB RS 641 215-CB

SPAM 150 C with test switch: Motor protection relay with: Over and undercurrent

protection, earth-fault protection, thermal overload for motors, phase

reversal/unbalance protection, motor start-up supervision

0

RS 641 214-DA RS 641 214-DA

SPAM 150 C with test switch: Motor protection relay with: Over and undercurrent

protection, earth-fault protection, thermal overload for motors, phase

reversal/unbalance protection, motor start-up supervision

0

RS 641 215-DB RS 641 215-DB

SPAM 150 C with test switch: Motor protection relay with: Over and undercurrent

protection, earth-fault protection, thermal overload for motors, phase

reversal/unbalance protection, motor start-up supervision

0

RS 641 214-FA RS 641 214-FA

SPAM 150 C with test switch: Motor protection relay with: Over and undercurrent

protection, earth-fault protection, thermal overload for motors, phase

reversal/unbalance protection, motor start-up supervision

0

RS 641 215-FB RS 641 215-FB

SPAM 150 C with test switch: Motor protection relay with: Over and undercurrent

protection, earth-fault protection, thermal overload for motors, phase

reversal/unbalance protection, motor start-up supervision

0

Page 74: ABBOfflineOrderNumberTool_Ver_15.41b_758059_ENg.xls

SACOAnnunciator Unit

Price

Item Order No. Description EUR

SACO 16D1-AA RS 811 016-AA Annunciator unit 80-265 V AC/DC 0

SACO 16D1-BA RS 811 016-BA Annunciator unit 18-80 V DC 0

SACO 16D3-AA RS 811 163-AA Annunciator unit 80-265 V AC/DC 0

SACO 16D3-BA RS 811 163-BA Annunciator unit 18-80 V DC 0

SACO 64C5B RS 813 064-AB

Signal grouping module Matrix for grouping of output signals. The unit has 4*16

inputs and 4*16 outputs and it is delivered with one set of programming wires (SWIR

39)

0

SACO 64D4-0-AA RS 811 640-AAAnnunciator unit 80-265 V DC + 80-265 V AC/DC Alarm system rack without

annunciator modules0

SACO 64D4-0-BA RS 811 640-BAAnnunciator unit 19-70 V DC + 80-265 V AC/DC Alarm system rack without

annunciator modules0

SACO 64D4-1-AA RS 811 641-AAAnnunciator unit 80-265 V DC + 80-265 V AC/DC Alarm system with 16 on/off

channels0

SACO 64D4-1-BA RS 811 641-BAAnnunciator unit 19-70 V DC + 80-265 V AC/DC Alarm system with 16 on/off

channels0

SACO 64D4-2-AA RS 811 642-AAAnnunciator unit 80-265 V DC + 80-265 V AC/DC Alarm system with 32 on/off

channels0

SACO 64D4-2-BA RS 811 642-BAAnnunciator unit 19-70 V DC + 80-265 V AC/DC Alarm system with 32 on/off

channels0

SACO 64D4-3-AA RS 811 643-AAAnnunciator unit 80-265 V DC + 80-265 V AC/DC Alarm system with 48 on/off

channels0

SACO 64D4-3-BA RS 811 643-BAAnnunciator unit 19-70 V DC + 80-265 V AC/DC Alarm system with 48 on/off

channels0

SACO 64D4-AA RS 811 644-AAAnnunciator unit 80-265 V DC + 80-265 V AC/DC Alarm system with 64 on/off

channels0

SACO 64D4-BA RS 811 644-BAAnnunciator unit 19-70 V DC + 80-265 V AC/DC Alarm system with 64 on/off

channels0

SWDM 3A1 RS 962 031-AA Push button unit for alarm reset (SACO 64D4) 0

Cables for connection between SACO units

SWIR 23 RS 952 001-AACables for serial interface connection SACO 16D2 <--> SACO 16D2 Cable for linking

of the 16 group signals between seven SACO 16D2 modules0

SWIR 25 RS 952 002-BACables for serial interface connection Cable for linking SPA bus <--> subracks, for

system with three racks0

SWIR 26 RS 952 002-CACables for serial interface connection Cable for linking SPA bus <--> subracks, for

system with four racks0

SWIR 27 RS 952 002-DACables for serial interface connection Cable for linking SPA bus <--> subracks, for

system with five racks0

SWIR 28 RS 952 002-FACables for serial interface connection Cable for linking SPA bus <--> subracks, for

system with six racks0

Page 75: ABBOfflineOrderNumberTool_Ver_15.41b_758059_ENg.xls

REC 523Remote Monitoring and Control Unit

Price

Item Order No. Description EUR

REC 523 F

REC523F 032AAA REC523F 032AAA Remote monitoring and control unit Uaux: 80 - 265 V AC/DC, 3 CT 1/5 A, wall mounted 0

REC523F 032CAA REC523F 032CAA Remote monitoring and control unit Uaux: 18 - 80 V DC, 3 CT 1/5 A, wall mounted 0

REC523F 033AAA REC523F 033AAARemote monitoring and control unit Uaux: 80 - 265 V AC/DC, 3 CT 1/5 A, 3 VT 100 V,

wall mounted0

REC523F 033CAA REC523F 033CAARemote monitoring and control unit Uaux: 18 - 80 V DC, 3 CT 1/5 A, 3 VT 100 V, wall

mounted0

REC523F 034AAA REC523F 034AAARemote monitoring and control unit Uaux: 80 - 265 V AC/DC, 4 CT 1/5 A, 3 VT 230 V,

wall mounted0

REC523F 034CAA REC523F 034CAARemote monitoring and control unit Uaux: 18 - 80 V DC, 4 CT 1/5 A, 3 VT 230 V, wall

mounted0

REC523F 037AAA REC523F 037AAARemote monitoring and control unit Uaux: 80 - 265 V AC/DC, 3 CT 1/5 A, flush

mounted,0

REC523F 037CAA REC523F 037CAA Remote monitoring and control unit Uaux: 18 - 80 V DC, 3 CT 1/5 A, flush mounted 0

REC523F 038AAA REC523F 038AAARemote monitoring and control unit Uaux: 80 - 265 V AC/DC, 3 CT 1/5 A, 3 VT 100 V,

flush mounted0

REC523F 038CAA REC523F 038CAARemote monitoring and control unit Uaux: 18 - 80 V DC, 3 CT 1/5 A, 3 VT 100 V, flush

mounted0

REC523F 039AAA REC523F 039AAARemote monitoring and control unit Uaux: 80 - 265 V AC/DC, 4 CT 1/5 A, 3 VT 230 V,

flush mounted0

REC523F 039CAA REC523F 039CAA Remote monitoring and control unit Uaux: 18 - 80 V DC, 4 CT 1/5 A, 3 VT 230 V 0

REC523F 054AAA REC523F 054AAARemote monitoring and control unit Uaux: 80 - 265 V AC/DC, 1 CT 0,2/1 A, 4 CT 1/5 A,

4 VT 100 V, wall mounted0

REC523F 054CAA REC523F 054CAARemote monitoring and control unit Uaux: 18 - 80 V DC, 1 CT 0,2/1 A, 4 CT 1/5 A, 4

VT 100 V, wall mounted0

REC523F 059AAA REC523F 059AAARemote monitoring and control unit Uaux: 80 - 265 V AC/DC, 1 CT 0,2/1 A, 4 CT 1/5 A,

4 VT 100 V, flush mounted0

REC523F 059CAA REC523F 059CAARemote monitoring and control unit Uaux: 18 - 80 V DC, 1 CT 0,2/1 A, 4 CT 1/5 A, 4

VT 100 V, flush mounted0

REC523F 060AAC REC523F 060AACRemote monitoring and control unit Uaux: 80 - 265 V AC/DC, 9 sensor channels

(current sensor or voltage divider), wall mounted0

REC523F 060CAC REC523F 060CACRemote monitoring and control unit Uaux: 18 - 80 V DC, 9 sensor channels (current

sensor or voltage divider), wall mounted0

REC523F 061AAA REC523F 061AAARemote monitoring and control unit Uaux: 80 - 265 V AC/DC, 6 CT 1/5 A, 3 VT 100 V,

wall mounted0

REC523F 061CAA REC523F 061CAARemote monitoring and control unit Uaux: 18 - 80 V DC, 6 CT 1/5 A, 3 VT 100 V, wall

mounted0

REC523F 062AAA REC523F 062AAARemote monitoring and control unit Uaux: 80 - 265 V AC/DC, 3 CT 1/5 A, 6 VT 100 V,

wall mounted0

REC523F 062CAA REC523F 062CAARemote monitoring and control unit Uaux: 18 - 80 V DC, 3 CT 1/5 A, 6 VT 100 V, wall

mounted0

REC523F 065AAC REC523F 065AACRemote monitoring and control unit Uaux: 80 - 265 V AC/DC, 9 sensor channels

(current sensor or voltage divider), flush mounted0

REC523F 065CAC REC523F 065CACRemote monitoring and control unit Uaux: 18 - 80 V DC, 9 sensor channels (current

sensor or voltage divider), flush mounted0

REC523F 066AAA REC523F 066AAARemote monitoring and control unit Uaux: 80 - 265 V AC/DC, 6 CT 1/5 A, 3 VT 100 V,

flush mounted0

REC523F 066CAA REC523F 066CAARemote monitoring and control unit Uaux: 18 - 80 V DC, 6 CT 1/5 A, 3 VT 100 V, flush

mounted0

REC523F 067AAA REC523F 067AAARemote monitoring and control unit Uaux: 80 - 265 V AC/DC, 3 CT 1/5 A, 6 VT 100 V,

flush mounted0