Transcript of ABB MCB
Short Form CatalogueP2
ABB System proM - the concept forsafety and comfort in electrical buildinginstallation.
ABB System proM, another range ofquality products from ABB. It isdistributed world-wide under thefamous ABB brand name.
Specifically marked for outstandingcommon features:
• Common outline and dimensions forall components, 17.5mm modulewidth, 68mm depth.
• Harmonized design of allcomponents result in homogenousoutlook - without any additionalmarking and smooth coordinationwithin the system.
• Two position catch for easypositioning and fixing on DIN rail.
• Common connection technique,dual-function terminals for mainproducts
• Marking possibility on allcomponents by common markinglabels.
• One common locking device forMCBs, RCD and isolators.
Conditions of sale and deliveryThe general delivery conditions for products and services of the electrical industry are valid in conjunction with the general sales conditions.Place of contract for delivery and payment as well as sole place of jurisdiction is Singapore.We reserve the right to make changes in designs, illustrations, dimensions, specifications, weights etc. without prior notice.
Miniature Circuit Breakers (MCBs) 5
Residual Current-Operated Devices (RCDs) 25
Consumer Units & Distribution Boards 33
Modular DIN-Rail Components (MDRCs) 47
Accessories for Connection & Installation 63
Selection Tables 67
Tripping Characteristics & Dimension Drawings 79
Contents
Short Form CatalogueP4
System proM
3kA Ranges: S230 Type B range 6
S230 Type C range 7
6kA Ranges: S250 Type B range 8
S250 Type C range 9
10kA Ranges: S270 Type B range 10
S270 Type C range 11
S270 Type K range 12
25kA Ranges: S280 Type B range 13
S280 Type C range 14
S280 Type K range 16
50kA Ranges: S500 Type B range 17
S500 Type C range 18
S500 Type D range 19
S500 Type K range 20
25kA Ranges: S700 Type E selective range 21
S700 Type K selective range 21
Accessories 22
P5
Miniature Circuit Breakers (MCBs)
The S2 range of MCBs complies to
international standards and regulations. All
S2 MCBs (except the S230 range) are
current limiting types and utilise the state of
the art “ hammer trip” principle.
Each pole is fitted with two different tripping
devices operating on a trip free switching
mechanism:
• the delayed thermal trip for
protection against overload, and
• the quick acting electromagnetic trip for
protection against short-circuits.
Each MCB have the following features:
• All round protection, IP 20
• Dual function terminals enables
simultaneous connection of busbar
and cables
• Easy positioning of the MCB on the
din rail with the mounting clip.
• Full range of accessories can be fitted
to the S2 range on site by user.
Miniature Circuit Breakers (MCBs)
Short Form CatalogueP6
Miniature Circuit Breakers
Single pole
Double pole
Triple pole
No. of Rated Ordering Details Order Code Price Packing Weight
poles Current Type No. 1 pc unit 1 pc
In A kg
1 6 S 231 - B 6 GJF 231 0001 R0604 10 0.125
10 S 231 - B 10 GJF 231 0001 R1004 10 0.125
16 S 231 - B 16 GJF 231 0001 R1604 10 0.125
20 S 231 - B 20 GJF 231 0001 R2004 10 0.125
25 S 231 - B 25 GJF 231 0001 R2504 10 0.125
32 S 231 - B 32 GJF 231 0001 R3204 10 0.125
40 S 231 - B 40 GJF 231 0001 R4004 10 0.125
50 S 231 - B 50 GJF 231 0001 R5004 10 0.148
63 S 231 - B 63 GJF 231 0001 R6304 10 0.148
2 6 S 232 - B 6 GJF 232 0001 R0604 5 0.250
10 S 232 - B 10 GJF 232 0001 R1004 5 0.250
16 S 232 - B 16 GJF 232 0001 R1604 5 0.250
20 S 232 - B 20 GJF 232 0001 R2004 5 0.250
25 S 232 - B 25 GJF 232 0001 R2504 5 0.250
32 S 232 - B 32 GJF 232 0001 R3204 5 0.250
40 S 232 - B 40 GJF 232 0001 R4004 5 0.250
50 S 232 - B 50 GJF 232 0001 R5004 5 0.300
63 S 232 - B 63 GJF 232 0001 R6304 5 0.300
3 6 S 233 - B 6 GJF 233 0001 R0604 3 0.375
10 S 233 - B 10 GJF 233 0001 R1004 3 0.375
16 S 233 - B 16 GJF 233 0001 R1604 3 0.375
20 S 233 - B 20 GJF 233 0001 R2004 3 0.375
25 S 233 - B 25 GJF 233 0001 R2504 3 0.375
32 S 233 - B 32 GJF 233 0001 R3204 3 0.375
40 S 233 - B 40 GJF 233 0001 R4004 3 0.375
50 S 233 - B 50 GJF 233 0001 R5004 3 0.443
63 S 233 - B 63 GJF 233 0001 R6304 3 0.443
S 230 Range Type B acc. to IEC 608983kA
P7
Miniature Circuit BreakersType C acc. to IEC 60898 S 230 Range
3kA
No. of Rated Ordering Details Order Code Price Packing Weight
poles Current Type No. 1 pc unit 1 pc
In A kg
1 6 S 231 - C 6 GJF 231 0001 R0605 10 0.125
10 S 231 - C 10 GJF 231 0001 R1005 10 0.125
16 S 231 - C 16 GJF 231 0001 R1605 10 0.125
20 S 231 - C 20 GJF 231 0001 R2005 10 0.125
25 S 231 - C 25 GJF 231 0001 R2505 10 0.125
32 S 231 - C 32 GJF 231 0001 R3205 10 0.125
40 S 231 - C 40 GJF 231 0001 R4005 10 0.125
50 S 231 - C 50 GJF 231 0001 R5005 10 0.148
63 S 231 - C 63 GJF 231 0001 R6305 10 0.148
2 6 S 232 - C 6 GJF 232 0001 R0605 5 0.250
10 S 232 - C 10 GJF 232 0001 R1005 5 0.250
16 S 232 - C 16 GJF 232 0001 R1605 5 0,250
20 S 232 - C 20 GJF 232 0001 R2005 5 0.250
25 S 232 - C 25 GJF 232 0001 R2505 5 0.250
32 S 232 - C 32 GJF 232 0001 R3205 5 0.250
40 S 232 - C 40 GJF 232 0001 R4005 5 0.250
50 S 232 - C 50 GJF 232 0001 R5005 5 0.300
63 S 232 - C 63 GJF 232 0001 R6305 5 0.300
3 6 S 233 - C 6 GJF 233 0001 R0605 3 0.375
10 S 233 - C 10 GJF 233 0001 R1005 3 0.375
16 S 233 - C 16 GJF 233 0001 R1605 3 0.375
20 S 233 - C 20 GJF 233 0001 R2005 3 0.375
25 S 233 - C 25 GJF 233 0001 R2505 3 0.375
32 S 233 - C 32 GJF 233 0001 R3205 3 0.375
40 S 233 - C 40 GJF 233 0001 R4005 3 0.375
50 S 233 - C 50 GJF 233 0001 R5005 3 0.443
63 S 233 - C 63 GJF 233 0001 R6305 3 0.443
MCBs with switched neutral (1+NA, 3+NA) on request.
Single pole
Double pole
Triple pole
Short Form CatalogueP8
Miniature Circuit Breakers
Single pole
Double pole
Triple pole
No. of Rated Ordering Details Order Code Price Packing Weight
poles Current Type No. 1 pc unit 1 pc
In A kg
1 6 S 251 - B 6 GJF 251 0001 R0604 10 0.125
10 S 251 - B 10 GJF 251 0001 R1004 10 0.125
16 S 251 - B 16 GJF 251 0001 R1604 10 0.125
20 S 251 - B 20 GJF 251 0001 R2004 10 0.125
25 S 251 - B 25 GJF 251 0001 R2504 10 0.125
32 S 251 - B 32 GJF 251 0001 R3204 10 0.125
40 S 251 - B 40 GJF 251 0001 R4004 10 0.125
50 S 251 - B 50 GJF 251 0001 R5004 10 0.130
63 S 251 - B 63 GJF 251 0001 R6304 10 0.130
2 6 S 252 - B 6 GJF 252 0001 R0604 5 0.250
10 S 252 - B 10 GJF 252 0001 R1004 5 0.250
16 S 252 - B 16 GJF 252 0001 R1604 5 0.250
20 S 252 - B 20 GJF 252 0001 R2004 5 0.250
25 S 252 - B 25 GJF 252 0001 R2504 5 0.250
32 S 252 - B 32 GJF 252 0001 R3204 5 0.250
40 S 252 - B 40 GJF 252 0001 R4004 5 0.250
50 S 232 - B 50 GJF 252 0001 R5004 5 0.260
63 S 252 - B 63 GJF 252 0001 R6304 5 0.260
3 6 S 253 - B 6 GJF 253 0001 R0604 3 0.375
10 S 253 - B 10 GJF 253 0001 R1004 3 0.375
16 S 253 - B 16 GJF 253 0001 R1604 3 0.375
20 S 253 - B 20 GJF 253 0001 R2004 3 0.375
25 S 253 - B 25 GJF 253 0001 R2504 3 0.375
32 S 253 - B 32 GJF 253 0001 R3204 3 0.375
40 S 253 - B 40 GJF 253 0001 R4004 3 0.375
50 S 253 - B 50 GJF 253 0001 R5004 3 0.390
63 S 253 - B 63 GJF 253 0001 R6304 3 0.390
S 250 Range Type B acc. to IEC 608986kA
P9
Single pole
Double pole
Triple pole
Miniature Circuit Breakers
No. of Rated Ordering Details Order Code Price Packing Weight
poles Current Type No. 1 pc unit 1 pc
In A kg
1 6 S 251 - C 6 GJF 251 0001 R0605 10 0.125
10 S 251 - C 10 GJF 251 0001 R1005 10 0.125
16 S 251 - C 16 GJF 251 0001 R1605 10 0.125
20 S 251 - C 20 GJF 251 0001 R2005 10 0.125
25 S 251 - C 25 GJF 251 0001 R2505 10 0.125
32 S 251 - C 32 GJF 251 0001 R3205 10 0.125
40 S 251 - C 40 GJF 251 0001 R4005 10 0125
50 S 251 - C 50 GJF 251 0001 R5005 10 0.130
63 S 251 - C 63 GJF 251 0001 R6305 10 0.130
2 6 S 252 - C 6 GJF 252 0001 R0605 5 0.250
10 S 252 - C 10 GJF 252 0001 R1005 5 0.250
16 S 252 - C 16 GJF 252 0001 R1605 5 0250
20 S 252 - C 20 GJF 252 0001 R2005 5 0.250
25 S 252 - C 25 GJF 252 0001 R2505 5 0.250
32 S 252 - C 32 GJF 252 0001 R3205 5 0.250
40 S 252 - C 40 GJF 252 0001 R4005 5 0.250
50 S 232 - C 50 GJF 252 0001 R5005 5 0.260
63 S 252 - C 63 GJF 252 0001 R6305 5 0.260
3 6 S 253 - C 6 GJF 253 0001 R0605 3 0.375
10 S 253 - C 10 GJF 253 0001 R1005 3 0.375
16 S 253 - C 16 GJF 253 0001 R1605 3 0.375
20 S 253 - C 20 GJF 253 0001 R2005 3 0.375
25 S 253 - C 25 GJF 253 0001 R2505 3 0.375
32 S 253 - C 32 GJF 253 0001 R3205 3 0.375
40 S 253 - C 40 GJF 253 0001 R4005 3 0.375
50 S 253 - C 50 GJF 253 0001 R5005 3 0.390
63 S 253 - C 63 GJF 253 0001 R6305 3 0.390
MCBs with switched neutral (1+NA, 3+NA) on request.
Type C acc. to IEC 60898 S 250 Range6kA
Short Form CatalogueP10
Miniature Circuit Breakers
Single pole
Double pole
Triple pole
No. of Rated Ordering Details Order Code Price Packing Weight
poles Current Type No. 1 pc unit 1 pc
In A kg
1 6 S 271 - B 6 GJF 271 0001 R0604 10 0.125
10 S 271 - B 10 GJF 271 0001 R1004 10 0.125
16 S 271 - B 16 GJF 271 0001 R1604 10 0.125
20 S 271 - B 20 GJF 271 0001 R2004 10 0.125
25 S 271 - B 25 GJF 271 0001 R2504 10 0.125
32 S 271 - B 32 GJF 271 0001 R3204 10 0.125
40 S 271 - B 40 GJF 271 0001 R4004 10 0.125
50 S 271 - B 50 GJF 271 0001 R5004 10 0.130
63 S 271 - B 63 GJF 271 0001 R6304 10 0.130
2 6 S 272 - B 6 GJF 272 0001 R0604 5 0.250
10 S 272 - B 10 GJF 272 0001 R1004 5 0.250
16 S 272 - B 16 GJF 272 0001 R1604 5 0.250
20 S 272 - B 20 GJF 272 0001 R2004 5 0250
25 S 272 - B 25 GJF 272 0001 R2504 5 0.250
32 S 272 - B 32 GJF 272 0001 R3204 5 0.250
40 S 272 - B 40 GJF 272 0001 R4004 5 0.250
50 S 272 - B 50 GJF 272 0001 R5004 5 0.260
63 S 272 - B 63 GJF 272 0001 R6304 5 0.260
3 6 S 273 - B 6 GJF 273 0001 R0604 3 0.375
10 S 273 - B 10 GJF 273 0001 R1004 3 0.375
16 S 273 - B 16 GJF 273 0001 R1604 3 0.375
20 S 273 - B 20 GJF 273 0001 R2004 3 0.375
25 S 273 - B 25 GJF 273 0001 R2504 3 0.375
32 S 273 - B 32 GJF 273 0001 R3204 3 0.375
40 S 273 - B 40 GJF 273 0001 R4004 3 0.375
50 S 273 - B 50 GJF 273 0001 R5004 3 0.390
63 S 273 - B 63 GJF 273 0001 R6304 3 0.390
S 270 Range Type B acc. to IEC 6089810kA
P11
Miniature Circuit Breakers
Single pole
Double pole
Triple pole
S270-C80 to C100
No. of Rated Ordering Details Order Code Price Packing Weight
poles Current Type No. 1 pc unit 1 pc
In A kg
1 0.5 S 271 - C 0.5 GJF 271 0001 R 9805 10 0.1251 S 271 - C 1 GJF 271 0001 R 0105 10 0.125
1.6 S 271 - C 1.6 GJF 271 0001 R 9705 10 0.1252 S 271 - C 2 GJF 271 0001 R 0205 10 0.1253 S 271 - C 3 GJF 271 0001 R 0305 10 0.1254 S 271 - C 4 GJF 271 0001 R 0405 10 0.1256 S 271 - C 6 GJF 271 0001 R 0605 10 0.1258 S 271 - C 8 GJF 271 0001 R 0805 10 0.12510 S 271 - C 10 GJF 271 0001 R 1005 10 0.12516 S 271 - C 16 GJF 271 0001 R 1605 10 0.12520 S 271 - C 20 GJF 271 0001 R 2005 10 0.12525 S 271 - C 25 GJF 271 0001 R 2505 10 0.12532 S 271 - C 32 GJF 271 0001 R 3205 10 0.12540 S 271 - C 40 GJF 271 0001 R 4005 10 0.12550 S 271 - C 50 GJF 271 0001 R 5005 10 0.13063 S 271 - C 63 GJS 271 0001 R 6305 10 0.13080 S 271 - C 80 GHS 271 3001 R 0804 6 0.260
100 S 271 - C 100 GHS 271 3001 R 0824 6 0.260
2 0.5 S 272 - C 0.5 GJF 272 0001 R 9805 5 0.2501 S 272 - C 1 GJF 272 0001 R 0105 5 0.250
1.6 S 272 - C 1.6 GJF 272 0001 R 9705 5 0.2502 S 272 - C 2 GJF 272 0001 R 0205 5 0.2503 S 272 - C 3 GJF 272 0001 R 0305 5 0.2504 S 272 - C 4 GJF 272 0001 R 0405 5 0.2506 S 272 - C 6 GJF 272 0001 R 0605 5 0.2508 S 272 - C 8 GJF 272 0001 R 0805 5 0.25010 S 272 - C 10 GJF 272 0001 R 1005 5 0.25016 S 272 - C 16 GJF 272 0001 R 1605 5 0.25020 S 272 - C 20 GJF 272 0001 R 2005 5 0.25025 S 272 - C 25 GJF 272 0001 R 2505 5 0.25032 S 272 - C 32 GJF 272 0001 R 3205 5 0.25040 S 272 - C 40 GJF 272 0001 R 4005 5 0.25050 S 272 - C 50 GJF 272 0001 R 5005 5 0.26063 S 272 - C 63 GJF 272 0001 R 6305 5 0.26080 S 272 - C 80 GHS 272 3001 R 0804 3 0.520
100 S 272 - C 100 GHS 272 3001 R 0824 3 0.520
3 0.5 S 273 - C 0.5 GJF 273 0001 R 9805 3 0.3751 S 273 - C 1 GJF 273 0001 R 0105 3 0.375
1.6 S 273 - C 1.6 GJF 273 0001 R 9705 3 0.3752 S 273 - C 2 GJF 273 0001 R 0205 3 0.3753 S 273 - C 3 GJF 273 0001 R 0305 3 0.3754 S 273 - C 4 GJF 273 0001 R 0405 3 0.3756 S 273 - C 6 GJF 273 0001 R 0605 3 0.3758 S 273 - C 8 GJF 273 0001 R 0805 3 0.37510 S 273 - C 10 GJF 273 0001 R 1005 3 0.37516 S 273 - C 16 GJF 273 0001 R 1605 3 0.37520 S 273 - C 20 GJF 273 0001 R 2005 3 0.37525 S 273 - C 25 GJF 273 0001 R 2505 3 0.37532 S 273 - C 32 GJF 273 0001 R 3205 3 0.37540 S 273 - C 40 GJF 273 0001 R 4005 3 0.37550 S 273 - C 50 GJF 273 0001 R 5005 3 0.39063 S 273 - C 63 GJF 273 0001 R 6305 3 0.39080 S 273 - C 80 GHS 273 3001 R 0804 2 0.790
100 S 273 - C 100 GHS 273 3001 R 0824 2 0.790
Type C acc. to IEC 60898 S 270 Range10kA
Short Form CatalogueP12
Miniature Circuit Breakers
Single pole
Double pole
Triple pole
MCBs with switched neutral (1+NA, 3+NA) and 4 poles on request.
No. of Rated Ordering Details Order Code Price Packing Weight
poles Current Type No. 1 pc unit 1 pc
In A kg
1 0.5 S 271 - K 0.5 GHS 271 0001 R 0157 10 0.125
1 S 271 - K 1 GHS 271 0001 R 0217 10 0.125
1.6 S 271 - K 1.6 GHS 271 0001 R 0257 10 0.125
2 S 271 - K 2 GHS 271 0001 R 0277 10 0.125
3 S 271 - K 3 GHS 271 0001 R 0317 10 0.125
4 S 271 - K 4 GHS 271 0001 R 0337 10 0.125
6 S 271 - K 6 GHS 271 0001 R 0377 10 0.125
8 S 271 - K 8 GHS 271 0001 R 0407 10 0.125
10 S 271 - K 10 GHS 271 0001 R 0427 10 0.125
16 S 271 - K 16 GHS 271 0001 R 0467 10 0.125
20 S 271 - K 20 GHS 271 0001 R 0487 10 0.125
25 S 271 - K 25 GHS 271 0001 R 0517 10 0.125
32 S 271 - K 32 GHS 271 0001 R 0537 10 0.125
40 S 271 - K 40 GHS 271 0001 R 0557 10 0.125
50 S 271 - K 50 GHS 271 0001 R 0577 10 0.130
63 S 271 - K 63 GHS 271 0001 R 0607 10 0.130
2 0.5 S 272 - K 0.5 GHS 272 0001 R 0157 5 0.250
1 S 272 - K 1 GHS 272 0001 R 0217 5 0.250
1.6 S 272 - K 1.6 GHS 272 0001 R 0257 5 0.250
2 S 272 - K 2 GHS 272 0001 R 0277 5 0.250
3 S 272 - K 3 GHS 272 0001 R 0317 5 0.250
4 S 272 - K 4 GHS 272 0001 R 0337 5 0.250
6 S 272 - K 6 GHS 272 0001 R 0377 5 0.250
8 S 272 - K 8 GHS 272 0001 R 0407 5 0.250
10 S 272 - K 10 GHS 272 0001 R 0427 5 0.250
16 S 272 - K 16 GHS 272 0001 R 0467 5 0.250
20 S 272 - K 20 GHS 272 0001 R 0487 5 0.250
25 S 272 - K 25 GHS 272 0001 R 0517 5 0.250
32 S 272 - K 32 GHS 272 0001 R 0537 5 0.250
40 S 272 - K 40 GHS 272 0001 R 0557 5 0.250
50 S 272 - K 50 GHS 272 0001 R 0577 5 0.260
63 S 272 - K 63 GHS 272 0001 R 0607 5 0.260
3 0.5 S 273 - K 0.5 GHS 273 0001 R 0157 3 0.375
1 S 273 - K 1 GHS 273 0001 R 0217 3 0.375
1.6 S 273 - K 1.6 GHS 273 0001 R 0257 3 0.375
2 S 273 - K 2 GHS 273 0001 R 0277 3 0.375
3 S 273 - K 3 GHS 273 0001 R 0317 3 0.375
4 S 273 - K 4 GHS 273 0001 R 0337 3 0.375
6 S 273 - K 6 GHS 273 0001 R 0377 3 0.375
8 S 273 - K 8 GHS 273 0001 R 0407 3 0.375
10 S 273 - K 10 GHS 273 0001 R 0427 3 0.375
16 S 273 - K 16 GHS 273 0001 R 0467 3 0.375
20 S 273 - K 20 GHS 273 0001 R 0487 3 0.375
25 S 273 - K 25 GHS 273 0001 R 0517 3 0.375
32 S 273 - K 32 GHS 273 0001 R 0537 3 0.375
40 S 273 - K 40 GHS 273 0001 R 0557 3 0.375
50 S 273 - K 50 GHS 273 0001 R 0577 3 0.390
63 S 273 - K 63 GHS 273 0001 R 0607 3 0.390
S 270 Range Type K acc. to IEC 60947-210kA
P13
Miniature Circuit Breakers
Single pole
Double pole
Triple pole
No. of Rated Ordering Details Order Code Price Packing Weight
poles Current Type No. 1 pc unit 1 pc
In A kg
1 6 S 281 - B 6 GHS 281 0001 R 0065 10 0.130
10 S 281 - B 10 GHS 281 0001 R 0105 10 0.130
13 S 281 - B 13 GHS 281 0001 R 0135 10 0.130
16 S 281 - B 16 GHS 281 0001 R 0165 10 0.130
20 S 281 - B 20 GHS 281 0001 R 0205 10 0.130
25 S 281 - B 25 GHS 281 0001 R 0255 10 0.130
32 S 281 - B 32 GHS 281 0001 R 0325 10 0.130
40 S 281 - B 40 GHS 281 0001 R 0405 10 0.130
50 S 281 - B 50 GHS 281 0001 R 0505 10 0.160
63 S 281 - B 63 GHS 281 0001 R 0635 10 0.160
2 6 S 282 - B 6 GHS 282 0001 R 0065 5 0.260
10 S 282 - B 10 GHS 282 0001 R 0105 5 0.260
13 S 282 - B 13 GHS 282 0001 R 0135 5 0.260
16 S 282 - B 16 GHS 282 0001 R 0165 5 0.260
20 S 282 - B 20 GHS 282 0001 R 0205 5 0.260
25 S 282 - B 25 GHS 282 0001 R 0255 5 0.260
32 S 282 - B 32 GHS 282 0001 R 0325 5 0.260
40 S 282 - B 40 GHS 282 0001 R 0405 5 0.260
50 S 282 - B 50 GHS 282 0001 R 0505 5 0.320
63 S 282 - B 63 GHS 282 0001 R 0635 5 0.320
3 6 S 283 - B 6 GHS 283 0001 R 0065 3 0.390
10 S 283 - B 10 GHS 283 0001 R 0105 3 0.390
13 S 283 - B 13 GHS 283 0001 R 0135 3 0.390
16 S 283 - B 16 GHS 283 0001 R 0165 3 0.390
20 S 283 - B 20 GHS 283 0001 R 0205 3 0.390
25 S 283 - B 25 GHS 283 0001 R 0255 3 0.390
32 S 283 - B 32 GHS 283 0001 R 0325 3 0.390
40 S 283 - B 40 GHS 283 0001 R 0405 3 0.390
50 S 283 - B 50 GHS 283 0001 R 0505 3 0.480
63 S 283 - B 63 GHS 283 0001 R 0635 3 0.480
MCBs with switched neutral & 4 poles on request.
Type B acc. to IEC 60898 S 280 Range25kA
Short Form CatalogueP14
Miniature Circuit Breakers
Single pole
Double pole
No. of Rated Ordering Details Order Code Price Packing Weight
poles Current Type No. 1 pc unit 1 pc
In A kg
1 0.5 S 281 - C 0.5 GHS 281 0001 R 0984 10 0.130
1 S 281 - C 1 GHS 281 0001 R 0014 10 0.130
1.6 S 281 - C 1.6 GHS 281 0001 R 0974 10 0.130
2 S 281 - C 2 GHS 281 0001 R 0024 10 0.130
3 S 281 - C 3 GHS 281 0001 R 0034 10 0.130
4 S 281 - C 4 GHS 281 0001 R 0044 10 0.130
6 S 281 - C 6 GHS 281 0001 R 0064 10 0.130
8 S 281 - C 8 GHS 281 0001 R 0084 10 0.130
10 S 281 - C 10 GHS 281 0001 R 0104 10 0.130
13 S 281 - C 13 GHS 281 0001 R 0134 10 0.130
16 S 281 - C 16 GHS 281 0001 R 0164 10 0.130
20 S 281 - C 20 GHS 281 0001 R 0204 10 0.130
25 S 281 - C 25 GHS 281 0001 R 0254 10 0.130
32 S 281 - C 32 GHS 281 0001 R 0324 10 0.130
40 S 281 - C 40 GHS 281 0001 R 0404 10 0.130
50 S 281 - C 50 GHS 281 0001 R 0504 10 0.160
63 S 281 - C 63 GHS 281 0001 R 0634 10 0.160
2 0.5 S 282 - C 0.5 GHS 282 0001 R 0984 5 0.260
1 S 282 - C 1 GHS 282 0001 R 0014 5 0.260
1.6 S 282 - C 1.6 GHS 282 0001 R 0974 5 0.260
2 S 282 - C 2 GHS 282 0001 R 0024 5 0.260
3 S 282 - C 3 GHS 282 0001 R 0034 5 0.260
4 S 282 - C 4 GHS 282 0001 R 0044 5 0.260
6 S 282 - C 6 GHS 282 0001 R 0064 5 0.260
8 S 282 - C 8 GHS 282 0001 R0084 5 0.260
10 S 282 - C 10 GHS 282 0001 R 0104 5 0.260
13 S 282 - C 13 GHS 282 0001 R 0134 5 0.260
16 S 282 - C 16 GHS 282 0001 R 0164 5 0.260
20 S 282 - C 20 GHS 282 0001 R 0204 5 0.260
25 S 282 - C 25 GHS 282 0001 R 0254 5 0.260
32 S 282 - C 32 GHS 282 0001 R 0324 5 0.260
40 S 282 - C 40 GHS 282 0001 R 0404 5 0.260
50 S 282 - C 50 GHS 282 0001 R 0504 5 0.320
63 S 282 - C 63 GHS 282 0001 R 0634 5 0.320
S 280 Range Type C acc. to IEC 6089825kA
P15
Miniature Circuit Breakers
Triple pole
No. of Rated Ordering Details Order Code Price Packing Weight
poles Current Type No. 1 pc unit 1 pc
In A kg
3 0.5 S 283 - C 0.5 GHS 283 0001 R 0984 3 0.390
1 S 283 - C 1 GHS 283 0001 R 0014 3 0.390
1.6 S 283 - C 1.6 GHS 283 0001 R 0974 3 0.390
2 S 283 - C 2 GHS 283 0001 R 0024 3 0.390
3 S 283 - C 3 GHS 283 0001 R 0034 3 0.390
4 S 283 - C 4 GHS 283 0001 R 0044 3 0.390
6 S 283 - C 6 GHS 283 0001 R 0064 3 0.390
8 S 283 - C 8 GHS 283 0001 R 0084 3 0.390
10 S 283 - C 10 GHS 283 0001 R 0104 3 0.390
13 S 283 - C 13 GHS 283 0001 R 0134 3 0.390
16 S 283 - C 16 GHS 283 0001 R 0164 3 0.390
20 S 283 - C 20 GHS 283 0001 R 0204 3 0.390
25 S 283 - C 25 GHS 283 0001 R 0254 3 0.390
32 S 283 - C 32 GHS 283 0001 R 0324 3 0.390
40 S 283 - C 40 GHS 283 0001 R 0404 3 0.390
50 S 283 - C 50 GHS 283 0001 R 0504 3 0.480
63 S 283 - C 63 GHS 283 0001 R 0634 3 0.480
MCBs with switched neutral (1+NA, 3+NA) and 4 poles on request.
Type C acc. to IEC 60898 S 280 Range25kA
Short Form CatalogueP16
Miniature Circuit Breakers
Single pole
Triple pole
No. of Rated Ordering Details Order Code Price Packing Weight
poles Current Type No. 1 pc unit 1 pc
In A kg
1 0.2 S 281 - K 0.2 GHS 281 0001 R 0087 10 0.130
0.3 S 281 - K 0.3 GHS 281 0001 R 0117 10 0.130
0.5 S 281 - K 0.5 GHS 281 0001 R 0157 10 0.130
0.75 S 281 - K 0.75 GHS 281 0001 R 0187 10 0.130
1 S 281 - K 1 GHS 281 0001 R 0217 10 0.130
1.6 S 281 - K 1.6 GHS 281 0001 R 0257 10 0.130
2 S 281 - K 2 GHS 281 0001 R 0277 10 0.130
3 S 281 - K 3 GHS 281 0001 R 0317 10 0.130
4 S 281 - K 4 GHS 281 0001 R 0337 10 0.130
6 S 281 - K 6 GHS 281 0001 R 0377 10 0.130
8 S 281 - K 8 GHS 281 0001 R 0407 10 0,130
10 S 281 - K 10 GHS 281 0001 R 0427 10 0.130
13 S 281 - K 13 GHS 281 0001 R 0447 10 0.130
16 S 281 - K 16 GHS 281 0001 R 0467 10 0.130
20 S 281 - K 20 GHS 281 0001 R 0487 10 0.130
25 S 281 - K 25 GHS 281 0001 R 0517 10 0.130
32 S 281 - K 32 GHS 281 0001 R 0537 10 0.130
40 S 281 - K 40 GHS 281 0001 R 0557 10 0.130
50 S 281 - K 50 GHS 281 0001 R 0577 10 0.160
63 S 281 - K 63 GHS 281 0001 R 0607 10 0.160
3 0.2 S 283 - K 0.2 GHS 283 0001 R 0087 3 0.390
0.3 S 283 - K 0.3 GHS 283 0001 R 0117 3 0.390
0.5 S 283 - K 0.5 GHS 283 0001 R 0157 3 0.390
0.75 S 283 - K 0.75 GHS 283 0001 R 0187 3 0.390
1 S 283 - K 1 GHS 283 0001 R 0217 3 0.390
1.6 S 283 - K 1.6 GHS 283 0001 R 0257 3 0.390
2 S 283 - K 2 GHS 283 0001 R 0277 3 0.390
3 S 283 - K 3 GHS 283 0001 R 0317 3 0.390
4 S 283 - K 4 GHS 283 0001 R 0337 3 0.390
6 S 283 - K 6 GHS 283 0001 R 0377 3 0.390
8 S 283 - K 8 GHS 283 0001 R 0407 3 0.390
10 S 283 - K 10 GHS 283 0001 R 0427 3 0.390
13 S 283 - K 13 GHS 283 0001 R 0447 3 0.390
16 S 283 - K 16 GHS 283 0001 R 0467 3 0.390
20 S 283 - K 20 GHS 283 0001 R 0487 3 0.390
25 S 283 - K 25 GHS 283 0001 R 0517 3 0.390
32 S 283 - K 32 GHS 283 0001 R 0537 3 0.390
40 S 283 - K 40 GHS 283 0001 R 0557 3 0.390
50 S 283 - K 50 GHS 283 0001 R 0577 3 0.480
63 S 283 - K 63 GHS 283 0001 R 0607 3 0.480
MCBs with switched neutral 2 and 4 poles on request.
S 280 Range Type K acc. to IEC 60947-225kA
P17
Miniature Circuit Breakers
Single pole
No. of Rated Ordering Details Order Code Price Packing Weight
poles Current Type No. 1 pc unit 1 pc
In A kg
1 6 S 501 - B 6 GHS 501 0001 R 065 8 0.250
10 S 501 - B 10 GHS 501 0001 R 105 8 0.250
13 S 501 - B 13 GHS 501 0001 R 135 8 0.250
16 S 501 - B 16 GHS 501 0001 R 165 8 0.250
20 S 501 - B 20 GHS 501 0001 R 205 8 0.250
25 S 501 - B 25 GHS 501 0001 R 255 8 0.250
32 S 501 - B 32 GHS 501 0001 R 325 8 0.250
40 S 501 - B 40 GHS 501 0001 R 405 8 0.250
50 S 501 - B 50 GHS 501 0001 R 505 8 0.250
63 S 501 - B 63 GHS 501 0001 R 635 8 0.250
2 6 S 502 - B 6 GHS 502 0001 R 065 4 0.500
10 S 502 - B 10 GHS 502 0001 R 105 4 0.500
13 S 501 - B 13 GHS 502 0001 R 135 4 0.500
16 S 502 - B 16 GHS 502 0001 R 165 4 0.500
20 S 502 - B 20 GHS 502 0001 R 205 4 0.500
25 S 502 - B 25 GHS 502 0001 R 255 4 0.500
32 S 502 - B 32 GHS 502 0001 R 325 4 0.500
40 S 502 - B 40 GHS 502 0001 R 405 4 0.500
50 S 502 - B 50 GHS 502 0001 R 505 4 0.500
63 S 502 - B 63 GHS 502 0001 R 635 4 0.500
3 6 S 503 - B 6 GHS 503 0001 R 065 2 0.710
10 S 503 - B 10 GHS 503 0001 R 105 2 0.710
13 S 503 - B 13 GHS 503 0001 R 135 2 0.710
16 S 503 - B 16 GHS 503 0001 R 165 2 0.710
20 S 503 - B 20 GHS 503 0001 R 205 2 0.710
25 S 503 - B 25 GHS 503 0001 R 255 2 0.710
32 S 503 - B 32 GHS 503 0001 R 325 2 0.710
40 S 503 - B 40 GHS 503 0001 R 405 2 0.710
50 S 503 - B 50 GHS 503 0001 R 505 2 0.710
63 S 503 - B 63 GHS 503 0001 R 635 2 0.710
4 6 S 504 - B 6 GHS 504 0001 R 065 2 0.920
10 S 504 - B 10 GHS 504 0001 R 105 2 0.920
13 S 504 - B 13 GHS 504 0001 R 135 2 0.920
16 S 504 - B 16 GHS 504 0001 R 165 2 0.920
20 S 504 - B 20 GHS 504 0001 R 205 2 0.920
25 S 504 - B 25 GHS 504 0001 R 255 2 0.920
32 S 504 - B 32 GHS 504 0001 R 325 2 0.920
40 S 504 - B 40 GHS 504 0001 R 405 2 0.920
50 S 504 - B 50 GHS 504 0001 R 505 2 0.920
63 S 504 - B 63 GHS 504 0001 R 635 2 0.920
Type B acc. to IEC 60947-2 S 500 Range50kA
Single pole
Double pole
Triple pole
Short Form CatalogueP18
Miniature Circuit Breakers
Single pole
Double pole
Triple pole
No. of Rated Ordering Details Order Code Price Packing Weight
poles Current Type No. 1 pc unit 1 pc
In A kg
1 6 S 501 - C 6 GHS 501 0001 R 064 8 0.250
10 S 501 - C 10 GHS 501 0001 R 104 8 0.250
13 S 501 - C 13 GHS 501 0001 R 134 8 0.250
16 S 501 - C 16 GHS 501 0001 R 164 8 0.250
20 S 501 - C 20 GHS 501 0001 R 204 8 0.250
25 S 501 - C 25 GHS 501 0001 R 254 8 0.250
32 S 501 - C 32 GHS 501 0001 R 324 8 0.250
40 S 501 - C 40 GHS 501 0001 R 404 8 0.250
50 S 501 - C 50 GHS 501 0001 R 504 8 0.250
63 S 501 - C 63 GHS 501 0001 R 634 8 0.250
2 6 S 502 - C 6 GHS 502 0001 R 064 4 0.500
10 S 502 - C 10 GHS 502 0001 R 104 4 0.500
13 S 502 - C 13 GHS 502 0001 R 134 4 0.500
16 S 502 - C 16 GHS 502 0001 R 164 4 0.500
20 S 502 - C 20 GHS 502 0001 R 204 4 0.500
25 S 502 - C 25 GHS 502 0001 R 254 4 0.500
32 S 502 - C 32 GHS 502 0001 R 324 4 0.500
40 S 502 - C 40 GHS 502 0001 R 404 4 0.500
50 S 502 - C 50 GHS 502 0001 R 504 4 0.500
63 S 502 - C 63 GHS 502 0001 R 634 4 0.500
3 6 S 503 - C 6 GHS 503 0001 R 064 2 0.710
10 S 503 - C 10 GHS 503 0001 R 104 2 0.710
13 S 503 - C 13 GHS 503 0001 R 134 2 0.710
16 S 503 - C 16 GHS 503 0001 R 164 2 0.710
20 S 503 - C 20 GHS 503 0001 R 204 2 0.710
25 S 503 - C 25 GHS 503 0001 R 254 2 0.710
32 S 503 - C 32 GHS 503 0001 R 324 2 0.710
40 S 503 - C 40 GHS 503 0001 R 404 2 0.710
50 S 503 - C 50 GHS 503 0001 R 504 2 0.710
63 S 503 - C 63 GHS 503 0001 R 634 2 0.710
4 6 S 504 - C 6 GHS 504 0001 R 064 2 0.920
10 S 504 - C 10 GHS 504 0001 R 104 2 0.920
13 S 504 - C 13 GHS 504 0001 R 134 2 0.920
16 S 504 - C 16 GHS 504 0001 R 164 2 0.920
20 S 504 - C 20 GHS 504 0001 R 204 2 0.920
25 S 504 - C 25 GHS 504 0001 R 254 2 0.920
32 S 504 - C 32 GHS 504 0001 R 324 2 0.920
40 S 504 - C 40 GHS 504 0001 R 404 2 0.920
50 S 504 - C 50 GHS 504 0001 R 504 2 0.920
63 S 504 - C 63 GHS 504 0001 R 634 2 0.920
S 500 Range Type C acc. to IEC 60947-250kA
P19
Miniature Circuit Breakers
No. of Rated Ordering Details Order Code Price Packing Weight
poles Current Type No. 1 pc unit 1 pc
In A kg
1 13 S 501 - D 13 GHS 501 0001 R 131 8 0.250
16 S 501 - D 16 GHS 501 0001 R 161 8 0.250
20 S 501 - D 20 GHS 501 0001 R 201 8 0.250
25 S 501 - D 25 GHS 501 0001 R 251 8 0.250
32 S 501 - D 32 GHS 501 0001 R 321 8 0.250
40 S 501 - D 40 GHS 501 0001 R 401 8 0.250
50 S 501 - D 50 GHS 501 0001 R 501 8 0.250
63 S 501 - D 63 GHS 501 0001 R 631 8 0.250
2 13 S 502 - D 13 GHS 502 0001 R 131 4 0.500
16 S 502 - D 16 GHS 502 0001 R 161 4 0.500
20 S 502 - D 20 GHS 502 0001 R 201 4 0.500
25 S 502 - D 25 GHS 502 0001 R 251 4 0.500
32 S 502 - D 32 GHS 502 0001 R 321 4 0.500
40 S 502 - D 40 GHS 502 0001 R 401 4 0.500
50 S 502 - D 50 GHS 502 0001 R 501 4 0.500
63 S 502 - D 63 GHS 502 0001 R 631 4 0.500
3 13 S 503 - D 13 GHS 503 0001 R 131 2 0.710
16 S 503 - D 16 GHS 503 0001 R 161 2 0.710
20 S 503 - D 20 GHS 503 0001 R 201 2 0.710
25 S 503 - D 25 GHS 503 0001 R 251 2 0.710
32 S 503 - D 32 GHS 503 0001 R 321 2 0.710
40 S 503 - D 40 GHS 503 0001 R 401 2 0.710
50 S 503 - D 50 GHS 503 0001 R 501 2 0.710
63 S 503 - D 63 GHS 503 0001 R 631 2 0.710
4 13 S 504 - D 13 GHS 504 0001 R 131 2 0.920
16 S 504 - D 16 GHS 504 0001 R 161 2 0.920
20 S 504 - D 20 GHS 504 0001 R 201 2 0.920
25 S 504 - D 25 GHS 504 0001 R 251 2 0.920
32 S 504 - D 32 GHS 504 0001 R 321 2 0.920
40 S 504 - D 40 GHS 504 0001 R 401 2 0.920
50 S 504 - D 50 GHS 504 0001 R 501 2 0.920
63 S 504 - D 63 GHS 504 0001 R 631 2 0.920
Type D acc. to IEC 60947-2 S 500 Range50kA
Single pole
Double pole
Triple pole
Short Form CatalogueP20
Miniature Circuit Breakers
No. of Rated Ordering Details Order Code Price Packing Weight
poles Current Type No. 1 pc unit 1 pc
In A kg
1 0.1 - 0.15 S 501 - K 0.15 GHS 501 0001 R 57 8 0.250
6.14 - 0.21 S 501 - K 0.21 GHS 501 0001 R 97 8 0.250
0.2 - 0.3 S 501 - K 0.3 GHS 501 0001 R 117 8 0.250
0.28 - 0.42 S 501 - K 0.42 GHS 501 0001 R 137 8 0.250
0.38 - 0.58 S 501 - K 0.58 GHS 501 0001 R 177 8 0.250
0.53 - 0.8 S 501 - K 0.8 GHS 501 0001 R 197 8 0.250
0.73 - 1.1 S 501 - K 1.1 GHS 501 0001 R 217 8 0.250
1.0 - 1.5 S 501 - K 1.5 GHS 501 0001 R 257 8 0.250
1.4 - 2.1 S 501 - K 2.1 GHS 501 0001 R 287 8 0.250
2 - 3 S 501 - K 3 GHS 501 0001 R 317 8 0.250
2.8 - 4.2 S 501 - K 4.2 GHS 501 0001 R 347 8 0.250
3.8 - 5.8 S 501 - K 5.8 GHS 501 0001 R 377 8 0.250
5.3 - 8 S 501 - K 8 GHS 501 0001 R 407 8 0.250
4.3 - 11 S 501 - K 11 GHS 501 0001 R 437 8 0.250
10 - 15 S 501 - K 15 GHS 501 0001 R 467 8 0.250
14 - 20 S 501 - K20 GHS 501 0001 R 487 8 0.250
18 - 26 S 501 - K 26 GHS 501 0001 R 517 8 0.250
23 - 32 S 501 - K 32 GHS 501 0001 R 537 8 0.250
29 - 37 S 501 - K 37 GHS 501 0001 R 547 8 0.250
34 - 41 S 501 - K 41 GHS 501 0001 R 557 8 0.250
38 - 45 S 501 - K 45 GHS 501 0001 R 567 8 0.250
3 0.1 - 0.15 S 503 - K 0.15 GHS 503 0001 R 57 2 0.710
6.14 - 0.21 S 503 - K 0.21 GHS 503 0001 R 97 2 0.710
0.2 - 0.3 S 503 - K 0.3 GHS 503 0001 R 117 2 0.710
0.28 - 0.42 S 503 - K 0.42 GHS 503 0001 R 137 2 0.710
0.38 - 0.58 S 503 - K 0.58 GHS 501 0001 R 177 2 0.710
0.53 - 0.8 S 503 - K 0.8 GHS 503 0001 R 197 2 0.710
0.73 - 1.1 S 503 - K 1.1 GHS 503 0001 R 217 2 0.710
1.0 - 1.5 S 503 - K 1.5 GHS 503 0001 R 257 2 0.710
1.4 - 2.1 S 503 - K 2.1 GHS 503 0001 R 287 2 0.710
2 - 3 S 503 - K 3 GHS 503 0001 R 317 2 0.710
2.8 - 4.2 S 503 - K 4.2 GHS 503 0001 R 347 2 0.710
3.8 - 5.8 S 503 - K 5.8 GHS 503 0001 R 377 2 0.710
5.3 - 8 S 503 - K 8 GHS 503 0001 R 407 2 0.710
4.3 - 11 S 503 - K 11 GHS 503 0001 R 437 2 0.710
10 - 15 S 503 - K 15 GHS 503 0001 R 467 2 0.710
14 - 20 S 503 - K20 GHS 503 0001 R 487 2 0.710
18 - 26 S 503 - K 26 GHS 503 0001 R 517 2 0.710
23 - 32 S 503 - K 32 GHS 503 0001 R 537 2 0.710
29 - 37 S 503 - K 37 GHS 503 0001 R 547 2 0.710
34 - 41 S 503 - K 41 GHS 503 0001 R 557 2 0.710
38 - 45 S 503 - K 45 GHS 503 0001 R 567 2 0.710
Single pole
Triple pole
MCBs with switched neutral 2 poles on request.
S 500 Range Type K acc. to IEC 60947-4-150kA
P21
Miniature Circuit Breakers
S701-K sel
No. of Rated Ordering Details Order Code Price Packing Weight
poles Current Type No. 1 pc unit 1 pc
In A kg
1 10 S 701 - E 10sel GHS 701 5001 R 0449 3 0.55
16 S 701 - E 16sel GHS 701 5001 R 0469 3 0.55
20 S 701 - E 20sel GHS 701 5001 R 0489 3 0.55
25 S 701 - E 25sel GHS 701 5001 R 0519 3 0.55
32 S 701 - E 32sel GHS 701 5001 R 0529 3 0.55
35 S 701 - E 35sel GHS 701 5001 R 0539 3 0.55
40 S 701 - E 40sel GHS 701 5001 R 0559 3 0.55
50 S 701 - E 50sel GHS 701 5001 R 0579 3 0.55
63 S 701 - E 63sel GHS 701 5001 R 0599 3 0.55
80 S 701 - E 80sel GHS 701 5001 R 0629 3 0.55
100 S 701 - E 100sel GHS 701 5001 R 0639 3 0.55
Type E sel
No. of Rated Ordering Details Order Code Price Packing Weight
poles Current Type No. 1 pc unit 1 pc
In A kg
1 16 S 701 - K 16sel GHS 701 5001 R 0467 3 0.55
20 S 701 - K 20sel GHS 701 5001 R 0487 3 0.55
25 S 701 - K 25sel GHS 701 5001 R 0517 3 0.55
35 S 701 - K 35sel GHS 701 5001 R 0537 3 0.55
40 S 701 - K 40sel GHS 701 5001 R 0557 3 0.55
50 S 701 - K 50sel GHS 701 5001 R 0577 3 0.55
63 S 701 - K 63sel GHS 701 5001 R 0597 3 0.55
80 S 701 - K 80sel GHS 701 5001 R 0627 3 0.55
100 S 701 - K 100sel GHS 701 5001 R 0637 3 0.55
Type K sel
Technical details & Accessories upon request.
Type E sel & Type K sel S 700 Range25kA
Short Form CatalogueP22
Miniature Circuit Breakers Add-on Supplementary Devices(for S250, S270 and S280 ranges only)
Description Ordering Details Order Code Price Packing Weight
Type No. 1 pc unit 1 pc
kg
Auxiliary contact with screw connection
1 NO + 1 NC S2-H11 GHS 270 1916 R 0001 1 0.04
2 NC S2-H02 GHS 270 1916 R 0002 1 0.04
2 NO S2-H20 GHS 270 1916 R 0003 1 0.04
Shunt trip
12-60 Vac/12-110Vac S2-A1 GHS 280 1909 R 0001 1 0.145
110-415Vac/110-250VDC S2-A2 GHS 280 1909 R 0002 1 0.145
Combined signal contact/auxiliary contact S/H
Signal contact/ S2-S/H GHS 280 1901 R 0008 1 0.05
Auxiliary contact
with screw connect
Under voltage trips
12V DC S2-UA 12 GHS 280 1911 R 0001 1 0.155
24V AC/DC S2-UA 24 GHS 280 1911 R 0002 1 0.155
48V AC/DC S2-UA 48 GHS 280 1911 R 0003 1 0.155
110V AC/DC S2-UA 110 GHS 280 1911 R 0004 1 0.155
220V AC/DC S2-UA 220 GHS 280 1911 R 0005 1 0.155
380V AC S2-UA 380 GHS 280 1911 R 0006 1 0.155
Mechanical tripping device for automatic (door/cover) interlocking
1 module, 17.5mm S2-BP EF 9988 1 0.035
1 module, 17.5mm S2-BPS EF 9996 1 0.035
(with signal contact)
S2-H11
S2-A..
S2-SH
S2-BP
P23
S2-NT
S290-H11
Description Ordering Details Order Code Price Packing Weight
Type No. 1 pc unit 1 pc
kg
Hand operated neutral
S2-NT GHS 270 1908 R 0001 1 0.06
Accessories for S270 C80 to C100
Auxiliary contact S 290-H 11 GHS 290 1916 R 0001 1 0.05
Signal contact S 290-S GHS 290 1902 R 0008 1 0.05
Survey of the installation possibilities of accessories on S2...and F2... range, except for S230, S270 ( C80 & C100 range )
Short Form CatalogueP24
System proM
RCCBs F 360 range 26
RCCBs F 370 range 27
RCCBs F 660 range 28
RCBOs DS 651 range 29
RCBOs GS 251S range 30
RCBOs F 500 range 31
P25
Residual Current - Operated Devices(RCDs)Residual Current-operated devices areavailable in 3 basic ranges:
• Residual Current-operated CircuitBreakers (RCCBs), two and fourpoles with rated currents up to 125Aand residual currents 10-30-100-300-500 mA.
• MCB/RCB combinations (or RCBOs),two, three and four poles with ratedcurrent up to 63A and residual current30-100-300-500-1000 mA. RCB blockscan be attached to the MCBs at site.
• High sensitive RCBOs, “ABB-PeopleProtector”, single pole with switchedneutral and double pole with twoprotected poles for portable devices,with 10mA residual current sensitivityto protect human being againstfatal accidents at direct contact withelectrical live parts, eg. in bathroominstallation.
Residual Current-OperatedDevices (RCDs)
Short Form CatalogueP26
Residual Current-Operated Circuit Breaker (RCCBs)
F 362
F 364
No. of I ∆ n In Ordering Details Order Code Price Packing Weight
poles mA A Type No. 1 pc unit 1 pc
kg
2 10 16 F 362 - 16/0,01 GJF 362 0060 R 1601 1 0.345
2 30 32 F 362 - 32/0,03 GJF 362 0060 R 3202 1 0.345
30 40 F 362 - 40/0,03 GJF 362 0060 R 4002 1 0.345
30 63 F 362 - 63/0,03 GJF 362 0060 R 6302 1 0.365
2 100 32 F 362 - 32/0,1 GJF 362 0060 R 3203 1 0.345
100 40 F 362 - 40/0,1 GJF 362 0060 R 4003 1 0.345
100 63 F 362 - 63/0,1 GJF 362 0060 R 6303 1 0.365
2 300 32 F 362 - 32/0,3 GJF 362 0060 R 3204 1 0.345
300 40 F 362 - 40/0,3 GJF 362 0060 R 4004 1 0.345
300 63 F 362 - 63/0,3 GJF 362 0060 R 6304 1 0.365
4 30 32 F 364 - 32/0,03 GJF 364 0060 R 3202 1 0.430
30 40 F 364 - 40/0,03 GJF 364 0060 R 4002 1 0.430
30 63 F 364 - 63/0,03 GJF 364 0060 R 6302 1 0.490
4 100 32 F 364 - 32/0,1 GJF 364 0060 R 3203 1 0.430
100 40 F 364 - 40/0,1 GJF 364 0060 R 4003 1 0.430
100 63 F 364 - 63/0,1 GJF 364 0060 R 6303 1 0.490
4 300 32 F 364 - 32/0,3 GJF 364 0060 R 3204 1 0.430
300 40 F 364 - 40/0,3 GJF 364 0060 R 4004 1 0.430
300 63 F 364 - 63/0,3 GJF 364 0060 R 6304 1 0.490
F 360 Range
P27
Residual Current-Operated Circuit Breaker (RCCBs)
No. of I ∆ n In Ordering Details Order Code Price Packing Weight
poles mA A Type No. 1 pc unit 1 pc
kg
2 10 16 F 372 - 16/0,01 GHF 372 0001 R 1460 1 0.345
2 30 25 F 372 - 25/0,03 GHF 372 0001 R 2510 1 0.345
30 40 F 372 - 40/0,03 GHF 372 0001 R 2550 1 0.345
30 63 F 372 - 63/0,03 GHF 372 0001 R 2590 1 0.365
2 100 25 F 372 - 25/0,1 GHF 372 0001 R 3510 1 0.345
100 40 F 372 - 40/0,1 GHF 372 0001 R 3550 1 0.345
100 63 F 372 - 63/0,1 GHF 372 0001 R 3590 1 0.365
2 300 25 F 372 - 25/0,3 GHF 372 0001 R 4510 1 0.345
300 40 F 372 - 40/0,3 GHF 372 0001 R 4550 1 0.345
300 63 F 372 - 63/0,3 GHF 372 0001 R 4590 1 0.365
4 30 25 F 374 - 25/0,03 GHF 374 0001 R 2510 1 0.415
30 40 F 374 - 40/0,03 GHF 374 0001 R 2550 1 0.430
30 63 F 374 - 63/0,03 GHF 374 0001 R 2590 1 0.490
4 100 25 F 374 - 25/0,1 GHF 374 0001 R 3510 1 0.415
100 40 F 374 - 40/0,1 GHF 374 0001 R 3550 1 0.430
100 63 F 374 - 63/0,1 GHF 374 0001 R 3590 1 0.490
4 300 25 F 374 - 25/0,3 GHF 374 0001 R 4510 1 0.415
300 40 F 374 - 40/0,3 GHF 374 0001 R 4550 1 0.430
300 63 F 374 - 63/0,3 GHF 374 0001 R 4590 1 0.490
4 500 25 F 374 - 25/0,5 GHF 374 0001 R 5510 1 0.415
500 40 F 374 - 40/0,5 GHF 374 0001 R 5550 1 0.430
500 63 F 374 - 63/0,5 GHF 374 0001 R 5590 1 0.490
F 372
F 374
F 370 Range
Short Form CatalogueP28
Residual Current-Operated Circuit Breaker (RCCBs)
No. of I ∆ n In Ordering Details Order Code Price Packing Weight
poles mA A Type No. 1 pc unit 1 pc
kg
2 30 80 F 662 - 80/0.03 GHF 662 0015 R 2620 1 0.280
30 100 F 662 - 100/0.03 GHF 662 0015 R 2630 1 0.280
2 100 80 F 662 - 80/0.01 GHF 662 0015 R 3620 1 0.270
100 100 F 662 - 100/0.01 GHF 662 0015 R 3630 1 0.270
2 300 80 F 662 - 80/0.3 GHF 662 0015 R 4620 1 0.270
300 100 F 662 - 100/0.3 GHF 662 0015 R 4630 1 0.270
4 30 80 F 664 - 80/0.03 GHF 664 0015 R 2620 1 0.430
30 100 F 664 - 100/0.03 GHF 664 0015 R 2630 1 0.430
4 100 80 F 664 - 80/0.01 GHF 664 0015 R 3620 1 0.420
100 100 F 664 - 100/0.01 GHF 664 0015 R 3630 1 0.420
4 300 80 F 664 - 80/0.3 GHF 664 0015 R 4620 1 0.420
300 100 F 664 - 100/0.3 GHF 664 0015 R 4630 1 0.420
F 662
F 664
F 660 Range
P29
Residual Current-Operated Circuit Breaker (RCBOs)
No. of No. of In Ordering Details Order Code Price Packing Weight
poles modules A Type No. 1 pc unit 1 pc
protected kg
by MCB
1 2 6 DS 651 B 6/0,03 11170946 1 0.25
10 DS 651 B 10/0,03 11170948 1 0.25
16 DS 651 B 16/0,03 11170949 1 0.25
20 DS 651 B 20/0,03 11170950 1 0.25
25 DS 651 B 25/0,03 11170951 1 0.25
32 DS 651 B 32/0,03 11170952 1 0.25
1 2 6 DS 651 C 6/0,03 11170914 1 0.25
10 DS 651 C 10/0,03 11170915 1 0.25
16 DS 651 C 16/0,03 11170916 1 0.25
20 DS 651 C 20/0,03 11170917 1 0.25
25 DS 651 C 25/0,03 11170918 1 0.25
32 DS 651 C 32/0,03 11170919 1 0.25
DS 651
1. RCBOs with 300mA residual current on request.
with over-current protection 6kA DS 651 Range
Short Form CatalogueP30
Tripping No. of I ∆ n In Ordering Details Price Packing Weight
Characteristic poles mA A Type No. 1 pc unit 1 pc
kg
B 2 10 6 GS251S B 6/0,01 1 0.25
10 GS251S B 10/0,01 1 0.25
16 GS251S B 16/0,01 1 0.25
20 GS251S B 20/0,01 1 0.25
25 GS251S B 25/0,01 1 0.25
32 GS251S B 32/0,01 1 0.25
40 GS251S B 40/0,01 1 0.25
C 2 10 6 GS251S C 6/0,01 1 0.25
10 GS251S C 10/0,01 1 0.25
16 GS251S C 16/0,01 1 0.25
20 GS251S C 20/0,01 1 0.25
25 GS251S C 25/0,01 1 0.25
32 GS251S C 32/0,01 1 0.25
40 GS251S C 40/0,01 1 0.25
B 2 30 6 GS251S B 6/0,03 1 0.25
10 GS251S B 10/0,3 1 0.25
16 GS251S B 16/0,03 1 0.25
20 GS251S B 20/0,03 1 0.25
25 GS251S B 25/0,03 1 0.25
32 GS251S B 32/0,03 1 0.25
40 GS251S B 40/0,03 1 0.25
C 2 30 6 GS251S C 6/0,03 1 0.25
10 GS251S C 10/0,03 1 0.25
16 GS251S C 16/0,03 1 0.25
20 GS251S C 20/0,03 1 0.25
25 GS251S C 25/0,03 1 0.25
32 GS251S C 32/0,03 1 0.25
40 GS251S C 40/0,03 1 0.25
Residual Current-Operated Circuit Breaker (RCBOs)GS 251S Range 6kA with over-current protection
P31
Residual Current-Operated Circuit Breaker (RCBOs)
No. of I ∆ n In Ordering Details Order Code Price Packing Weight
poles mA A Type No. 1 pc unit 1 pc
kg
2 10 10 F 502 - C 10/0,01 GHF 502 1001 R 1104 1 0.82
13 F 502 - C 13/0,01 GHF 502 1001 R 1134 1 0.82
16 F 502 - C 16/0,01 GHF 502 1001 R 1164 1 0.82
20 F 502 - C 20/0,01 GHF 502 1001 R 1204 1 0.82
25 F 502 - C 25/0,01 GHF 502 1001 R 1254 1 0.82
2 30 10 F 502 - C 10/0,03 GHF 502 1001 R 2104 1 0.82
13 F 502 - C 13/0,03 GHF 502 1001 R 2134 1 0.82
16 F 502 - C 16/0,03 GHF 502 1001 R 2164 1 0.82
20 F 502 - C 20/0,03 GHF 502 1001 R 2204 1 0.82
25 F 502 - C 25/0,03 GHF 502 1001 R 2254 1 0.82
40 F 502 - C 40/0,03 GHF 502 1001 R 2404 1 0.82
50 F 502 - C 50/0,03 GHF 502 1001 R 2504 1 0.82
63 F 502 - C 63/0,03 GHF 502 1001 R 2634 1 0.82
2 300 10 F 502 - C 10/0,3 GHF 502 1001 R 4104 1 0.82
13 F 502 - C 13/0,3 GHF 502 1001 R 4134 1 0.82
16 F 502 - C 16/0,3 GHF 502 1001 R 4164 1 0.82
20 F 502 - C 20/0,3 GHF 502 1001 R 4204 1 0.82
25 F 502 - C 25/0,3 GHF 502 1001 R 4254 1 0.82
40 F 502 - C 40/0,3 GHF 502 1001 R 4404 1 0.82
50 F 502 - C 50/0,3 GHF 502 1001 R 4504 1 0.82
63 F 502 - C 63/0,3 GHF 502 1001 R 4634 1 0.82
4 10 10 F 504 - C 10/0,01 GHF 504 1001 R 1104 1 1.40
13 F 504 - C 13/0,01 GHF 504 1001 R 1134 1 1.40
16 F 504 - C 16/0,01 GHF 504 1001 R 1164 1 1.40
20 F 504 - C 20/0,01 GHF 504 1001 R 1204 1 1.40
25 F 504 - C 25/0,01 GHF 504 1001 R 1254 1 1.40
4 30 10 F 504 - C 10/0,03 GHF 504 1001 R 2104 1 1.40
13 F 504 - C 13/0,03 GHF 504 1001 R 2104 1 1.40
16 F 504 - C 16/0,03 GHF 504 1001 R 2104 1 1.40
20 F 504 - C 20/0,03 GHF 504 1001 R 2104 1 1.40
25 F 504 - C 25/0,03 GHF 504 1001 R 2104 1 1.40
40 F 504 - C 40/0,03 GHF 504 1001 R 2104 1 1.40
50 F 504 - C 50/0,03 GHF 504 1001 R 2104 1 1.40
63 F 504 - C 63/0,03 GHF 504 1001 R 2104 1 1.40
4 300 10 F 504 - C 10/0,3 GHF 504 1001 R 4104 1 1.40
13 F 504 - C 13/0,3 GHF 504 1001 R 4134 1 1.40
16 F 504 - C 16/0,3 GHF 504 1001 R 4164 1 1.40
20 F 504 - C 20/0,3 GHF 504 1001 R 4204 1 1.40
25 F 504 - C 25/0,3 GHF 504 1001 R 4254 1 1.40
40 F 504 - C 40/0,3 GHF 504 1001 R 4404 1 1.40
50 F 504 - C 50/0,3 GHF 504 1001 R 4504 1 1.40
63 F 504 - C 63/0,3 GHF 504 1001 R 4634 1 1.40
F 502
with over-current protection 50kA F 500 - C Range
System proM
Short Form CatalogueP32
Enclosures
Terminal Covers
SPE 34
Consumer Units
SCP Moulded plastic 35
SCC Metalclad with plastic flap 35
SCC Metalclad with steel flap 36
Weather Proof Enclosures 37
Distribution Boards
SDB - DB - Type B 38
SDB - DD - Type B Split-Busbar 38
SDB - DH - Type B 2-pole 3-phase Busbar 38
Panel Assemblies 39
Extension Boxes 40
Accessories 41
Fused Tap-Off Boxes 42
Electrical Meter Boxes 43
Electrical Meter Boards 44
P33
Consumer Units• For surface mounting, fully insulated,
high impact plastic with transparentflap, sheet steel in open design,transparent flap or steel flap.
• For recessed mounting, high impactplastic with transparent flap and sheetsteel wall box.
• For flush mounting, high impact plasticwith transparent flap and sheet steelwall box. Sheet steel open design withtransparent flap or steel flap.
An extremely wide range of consumer unitsallowing a great variety of configuration, forexample, dual tariff or split busbar units instandard enclosure.
All consumer units offer generous wiringspace and simple to break cable entries orknock-outs for easier installation at site.
Waterproof EnclosuresA wide range of IP 65/55 waterproof plasticenclosures for surface mounting in wetenvironments, manufactured from highimpact plastic material with various unitsfrom 3 modules to 32 modules withtransparent flaps.
Plastic enclosures with transparent or greycover for industrial applications.
Distribution BoardsSheet steel distribution boards for surfaceor flush mounting. Complete range of typeA and B boards to IEC 60439 -1 for singleor three phase supply. Maximum busbarrating 225A for conditional short-circuitcurrent up to 40kA.
Incoming devices offered include switch-isolators, MCCBs, MCBs, RCDs, fuse-switches or terminal blocks.
Special arrangement for connection of 2-pole MCBs to 3-phase supply.
Type A SPN and TPN, Type B TPN, forboth ranges split-busbar and dual tariffversions available.
Modular system for assembling of multi-unit boards, extension boxes for top,bottom and side complete the range.
Short Form CatalogueP34
Terminal Covers
Description Modules Ordering Details Order Code Price Packing Weight
Rows Type No. 1 pc unit 1 pc
kg
Terminal cover with base flap (IP 30) SPE Range
1 1 SPE 1/M GJF 175 1000 R 1014 1 0.110
1 1,2 SPE 1-2 GJF 175 2100 R 0002 1 0.110
1 2 SPE 2 GJF 175 2000 R 0002 1 0.110
1 3,4 SPE 3-4 GJF 175 4100 R 0002 1 0.150
1 4 SPE 4 GJF 175 4000 R 0002 1 0.150
Terminal cover with plastic flap (IP 40) SPE F Range
1 1 SPE F1 GJF 140 1909 R 0001 1 0.150
1 2 SPE F2 GJF 140 1910 R 0001 1 0.200
SPE 1/M
SPE 2
SPE 4
SPE F1
P35
Consumer Units SC RangeEmpty, without equipment
IEC 60439-3
Description Modules Ordering Details Order Code Price Packing Weight
Rows Type No. 1 pc unit 1 pc
kg
Moulded plastic, for surface mountingConsumer Units SCP...S
fitted with N plus PE terminals and equipment mounting rail.
1 7 SCP 07 SNB GJF 171 0211 R 0051 1 0.63
1 10 SCP 10 SNB GJF 171 0212 R 0081 1 0.80
1 14 SCP 14 SNB GJF 171 0214 R 0121 1 0.99
1 16 SCP 16 SNB GJF 171 0215 R 0141 1 1.09
1 20 SCP 20 SNB GJF 171 0216 R 0181 1 1.30
Moulded plastic, for recessed mountingConsumer Units SCP... R with steel wall box
fitted with N plus PE terminals and equipment mounting rail.
1 7 SCP 07 RNB GJF 171 0231 R 0051 1 1.62
1 10 SCP 10 RNB GJF 171 0232 R 0081 1 1.80
1 16 SCP 16 RNB GJF 171 0235 R 0141 1 2.17
1 20 SCP 20 RNB GJF 171 0236 R 0181 1 2.42
Metalclad with plastic flap, for surface mountingConsumer units SCC... S
fitted with N plus PE terminals and equipment mounting rail.
1 7 SCC 07 SNB GJF 171 2211 R 0051 1 1.64
1 10 SCC 10 SNB GJF 171 2212 R 0081 1 2.01
1 16 SCC 16 SNB GJF 171 2215 R 0141 1 2.75
1 20 SCC 20 SNB GJF 171 2216 R 0181 1 3.25
Three phase busbar blocks can be attached to bottom of MCBs/RCDs/isolators.
SCP 10 SNB
SCC 10 SNB
Short Form CatalogueP36
Consumer Units SC RangeEmpty, without equipmentIEC 60439-3
Description Modules Ordering Details Order Code Price Packing Weight
Rows Type No. 1 pc unit 1 pc
kg
Metalclad with plastic flap, for flush mountingConsumer Units SCC...F
fitted with N plus PE terminals and equipment mounting rail.
1 7 SCC 07 FNB GJF 171 2221 R 0051 1 1.59
1 10 SCC 10 FNB GJF 171 2222 R 0081 1 1.81
1 16 SCC 16 FNB GJF 171 2225 R 0141 1 2.26
1 20 SCC 20 FNB GJF 171 2226 R 0181 1 2.59
Metalclad with steel flap, for surface mounting.Consumer Units SCS... S with steel wall box
fitted with N plus PE terminals and equipment mounting rail.
1 7 SCS 07 SNB GJF 171 6211 R 0051 1 1.62
1 10 SCS 10 SNB GJF 171 6212 R 0081 1 1.83
1 16 SCS 16 SNB GJF 171 6215 R 0141 1 2.24
1 20 SCS 20 SNB GJF 171 6216 R 0181 1 2.51
Metalclad with steel flap, for flush mountingConsumer units SCS... F
fitted with N plus PE terminals and equipment mounting rail.
1 7 SCS 07 FNB GJF 171 6221 R 0051 1 1.72
1 10 SCS 10 FNB GJF 171 6222 R 0081 1 1.93
1 16 SCS 16 FNB GJF 171 6225 R 0141 1 2.34
1 20 SCS 20 FNB GJF 171 6226 R 0181 1 2.61
Three phase busbar blocks can be attached to bottom of MCBs/RCDs/isolators.
SCP 16 RNB
SCS 16 SNB
SCS 16 FNB
P37
Weather Proof Enclosures
Accessories e.g. terminal bars, key locks, loose doors etc avai lable.
CharacteristicsMaterial : Self-extinguishing Thermoplastic, resistant to abnormal heat and fire..Stability : Shock-proof, stable under continuous working conditions -25 degree C˚ to
+85 degree C˚ and high resistance to UV rays.Colours : Grey RAL 7035Approval : IMQ approved to CEI C431 IEC 60670
Surface Mounted Modular Enclosures
Modules Rows Dimensions (mm) Article No. Packing Weight
W x H x D unit kg
with vertically hinged opaque door IP 652/4 1 100 x 160 x 100 12722
4 1 140 x 220 x 140 12724
8 1 205 x 220 x 140 12728
12 1 275 x 220 x 140 12732
24 2 275 x 370 x 140 12734
36 3 275 x 570 x 140 12736
54 3 380 x 570 x 140 12738
with vertically hinged transparent door IP 652/4 1 100 x 160 x 100 12742
8 1 205 x 220 x 140 12748
12 1 275 x 220 x 140 12752
24 2 275 x 370 x 140 12754
36 3 275 x 570 x 140 12756
54 3 380 x 570 x 140 12758
Grey, with watertight spring closing transparent cover IP 554 1 125 x 180 x 105 12644
6 1 160 x 180 x 105 12646
10 1 230 x 180 x 105 12650
20 2 250 x 320 x 135 12652
Grey, with watertight lock closing transparent cover IP 554 1 125 x 180 x 105 12684
6 1 160 x 180 x 105 12686
10 1 230 x 180 x 105 12690
20 2 250 x 320 x 135 12692
Self- ExtinguishingThermoplastic
12754
12752
12690
12652
Short Form CatalogueP38
SDB Range Distribution BoardsIEC 60439-3
Description *Ways Ordering Details Order Code Price Packing Weight
Type of incoming Type No. 1 pc unit 1 pc
kg
Surface Mounting with door (1) - Type B TPN
For connection 4 SDB-DB 504 CL GJF 112 1011 R5600 1 9,86
with cable lugs 6 SDB-DB 506 CL GJF 112 1012 R5600 1 12,42
8 SDB-DB 508 CL GJF 112 1013 R5600 1 14,72
12 SDB-DB 512 CL GJF 112 1015 R5600 1 15,60
16 SDB-DB 516 CL GJF 112 1017 R5600 1 16,60
Switch-isolator 4 SDB-DB 504 MS/100 GJF 112 1011 R5040 1 10,26
100A 6 SDB-DB 506 MS/100 GJF 112 1012 R5040 1 12,56
8 SDB-DB 508 MS/100 GJF 112 1013 R5040 1 14,86
12 SDB-DB 512 MS/100 GJF 112 1015 R5040 1 17,16
MCCB 4 SDB-DB 504 MC/100 GJF 112 1011 R5100 1 10,84
100A 6 SDB-DB 506 MC/100 GJF 171 1012 R5100 1 13,14
8 SDB-DB 508 MC/100 GJF 112 1013 R5100 1 15,44
12 SDB-DB 512 MC/100 GJF 112 1015 R5100 1 17,74
DIN-rail mount 4 SDB-DB 504 MX GJF 112 1011 R5010 1 9,96
6 SDB-DB 506 MX GJF 112 1012 R5010 1 12,26
8 SDB-DB 508 MX GJF 112 1013 R5010 1 14,56
12 SDB-DB 512 MX GJF 112 1015 R5010 1 16,86
Surface Mounting with door (1) - Type B Split-Busbar TPN
DIN-rail mount 4+4 SDB-DD 504/504 MX GJF 114 1018 R5011 1 16,20
6+6 SDB-DD 506/506 MX GJF 114 1018 R5013 1 18,50
8+4 SDB-DD 508/504 MX GJF 114 1018 R5014 1 18,50
Surface Mounting with door (1) - Type B 2-pole 3-phase Busbar TPN
For connection 12 SDB-DH 512 CL GJF 116 1015 R5600 1 14,00
with cable lugs 18 SDB-DH 518 CL GJF 116 1018 R5600 1 16,20
1) If keylocks are preferred, suffix Type No with “KL”.
2) If gland plates with knockouts are required, suffix Type No with”/K”.
3) Unused MCB ways must be covered with blanking plate.
SDB-DB 506 MS/100 with SDB-EBF 2
SDB-DB 508 MX/100 with SDB-EBO 2
Type BSurface mounting
P39
SDB Range Distribution BoardsPanel Assemblies
SDB-BA 4 Busbar Assemblies
SDB-NT
SDB-ET
Description Ordering Details Order Code Price Packing Weight
Type No. 1 pc unit 1 pc
kg
Type B Busbar AssembliesFully shrouded, with connections for cable lugs, and for S2 range of MCBs.
4 ways SDB-BA 4 B1 GJF 110 1906 R0201 1 1.30
6 ways SDB-BA 4 B2 GJF 110 1906 R0202 1 1.50
8 ways SDB-BA 4 B3 GJF 110 1906 R0203 1 1.70
12 ways SDB-BA 4 B4 GJF 110 1906 R0204 1 2.12
16 ways SDB-BA 4 B5 GJF 110 1906 R0205 1 2.55
20 ways SDB-BA 4 B6 GJF 110 1906 R0206 1 2.95
24 ways SDB-BA 4 B7 GJF 110 1906 R0207 1 3.40
Neutral Multi-terminal Bars
3 terminals SDB-NT 3 GJF 110 1906 R0090 5 0.15
12 terminal SDB-NT 12 GJF 110 1906 R0091 5 0.65
15 terminals SDB-NT 15 GJF 110 1906 R0092 5 0.66
18 terminals SDB-NT 18 GJF 110 1906 R0093 5 0.71
24 terminals SDB-NT 24 GJF 110 1906 R0094 5 0.74
36 terminals SDB-NT 36 GJF 110 1906 R0095 5 0.80
48 terminals SDB-NT 48 GJF 110 1906 R0096 5 0.86
Earth Multi-terminal Bars
12 terminal SDB-ET 12 GJF 110 1906 R0101 5 0.65
15 terminals SDB-ET 15 GJF 110 1906 R0102 5 0.69
18 terminals SDB-ET 18 GJF 110 1906 R0103 5 0.72
24 terminals SDB-ET 24 GJF 110 1906 R0104 5 0.75
36 terminals SDB-ET 36 GJF 110 1906 R0105 5 0.81
48 terminals SDB-ET 48 GJF 110 1906 R0106 5 0.87
IEC 60439-3
Short Form CatalogueP40
SDB Range Distribution BoardsExtension Boxes Surface mounting & Flush mounting
IEC 60439-3
Dimension Ordering Details Order Code Price Packing Weight
Type No. 1 pc unit 1 pc
kg
Side Extension BoxesSDB-SEB...
with hinged door and DIN-Rails (13-module width opening).
450 x 380 x 130 mm (2 rows) SDB- SEB 2 GJF 110 1906 R0052 1 9.01
650 x 380 x 130 mm (3 rows) SDB- SEB 3 GJF 110 1906 R0053 1 12.41
750 x 380 x 130 mm (4 rows) SDB- SEB 4 GJF 110 1906 R0054 1 14.43
Top/Bottom Extension BoxesSDB-EBO...
without plates and without steel flap.
200 x 380 x 130 mm SDB- EBO 2 GJF 110 1906 R0012 1 2.57
300 x 380 x 130 mm SDB- EBO 5 GJF 110 1906 R0015 1 3.79
400 x 380 x 130 mm SDB- EBO 8 GJF 110 1906 R0018 1 4.03
SDB-EBF...
with steel flap and DIN-Rail, without gland plates.
200 x 380 x 130 mm SDB- EBF 2 GJF 110 1906 R0022 1 2.98
SDB-EBF 2
SDB-EBO 2
SDB-GP 2
SDB-GPK 2
P41
SDB Range Distribution BoardsAccessories
and Spare parts
SDB-DC
SDB-SB
SDB-CBS
SKB-ZS103
Description Ordering Details Order Code Price Packing Weight
Type No. 1 pc unit 1 pc
kg
Gland platesLength = 380 mm
Without knockouts SDB-GP2 GJF 110 1906 R0042 1 0.70
With knockouts SDB-GPK2 GJF 110 1906 R0045 1 0.70
Combination bolts (per set)for bolting two Distribution Boards
for surface mounting SDB-CBS GJF 110 1906 R0001 1 0.063
Keylock (with 2 keys)
for hinged doors SKV-ZS 103 GJF 110 1153 R0004 1 0.04
Door Catch
for hinged doors SDB-DC GJF 110 1153 R0001 1 0.01
Support Bar
Length - 380 mm SDB-SB2 GJF 110 1906 R0172 1 0.14
Short Form CatalogueP42
Fused Tap-Off Boxes
Fused Tap-Off Boxes
ABB Single-Phase Fused Tap-Off Boxes are designed for safe and easy electricity tap-off from thedistribution line of an electrical installation. It consists of three numbers of bimetal branch terminalsadequately sized for 25mm2 to 95mm2 cables. Each terminal allows for four tap-off connection pointssuitable for up to 25mm2 wire. Each box may be installed with one or two tap-off branches. The branchwires are safely protected by Double-Pole Moulded Case Circuit Breakers. The Tap-0ff Box is providedwith top and bottom flange plates suitable for 50 x 150 mm metal trunking entry.
Technical Data
Electrical Meter Board Type : AMP RangeSpecification : IEC 60439-1
IEC 60947-2IEC 998-1
Rated Current : 63A, 80A & 100ARated Voltage : 240V 50HzDegree of protection : IP40
MaterialEnclosure : EG sheet steel (1.2mmColour : RAL 1013Paint : Powder Coat Oven BakedFinish : Semi-gloss
Rating No. of Rupturing Type No. Order No. Price Packing Weight
(A) MCCB Capacity 1 pc unit 1 pc
(kA) kg
63 1 25 STB III-1-63A SGI 3130 1063 R971 1 8.20
2 25 STB III-2-63A SGI 3130 2063 R971 1 9.20
80 1 25 STB III-1-80A SGI 3130 1080 R971 1 8.20
2 25 STB III-2-80A SGI 3130 2080 R971 1 9.20
100 1 25 STB III-1-100A SGI 3130 1100 R971 1 8.20
2 25 STB III-2-100A SGI 3130 2100 R971 1 9.20
P43
Electrical Meter BoxesAMB range
Electrical Meter Boxes
ABB Electrical Meter Box provides a practical and economical solution to house the Incoming ServiceMCB, Consumer Main Switch and the KWH Meter into a neat and elegant unit. The Electrical Meter Boxoffers the necessary safety protection for isolation, overcurrent and, electric shock to the user, mechanicalprotection to the KWH meter and also prevent unauthorized access.
ABB Electrical Meter Box is fully factory-built and tested with internal connections. It is designed to complyto IEC 60439-1 with a minimum load of 63A.
Specifications and Features
Base : Electro-galvanized sheet steel (1.2 mm)Front Covers : Moulded Plastic PC ABS 2.5 mmViewing Window : High-impact polycarbonate
Ultra-violet stabilisedLight grey for base
Security : Sealable and / or lockable.MCB accessible only to consumer and supply authority.Protection for KWH meter.
Degree of Protection IP41
Rated Internal Connection Connections
Current (A) with PVC cable (mm2) Incoming (mm2) Outgoing (mm2) Earth (mm2)
32 10 25 - 50 25 - 50 4 x 16
40 10 25 - 50 25 - 50 4 x 16
63 16 25 - 50 25 - 50 4 x 16
MCB with other characteristics and duty available upon request.
Rating Incoming Consumer Type No. Order Code Price Packing Weight
(Amp) Service Swtich 1 pc unit 1 pc
Switch kg
32 MCB 2-pole Isolator AMB C-I-3206 SGI9690 R0607 1 4.56
Type C MCB 2-pole Type B AMB C-B-3206 SGI9690 R0608 1 4.56
40 MCB 2-pole Isolator AMP C-I-4006 SGI9690 R0609 1 4.56
Type C MCB 2-pole Type B AMP C-B-4006 SGI9690 R0610 1 4.56
63 MCB 2-pole Isolator AMP C-I-6306 SGI9690 R0611 1 4.56
Type C MCB 2-pole Type B AMP C-B-6306 SGI9690 R0612 1 4.56
Short Form CatalogueP44
Electrical Meter BoardsAMP range
and ATB range
Electrical Meter Boards
ABB Electrical Meter Board with Single-Phase Unfused Tap-Off Box are designed for safe and easyelectricity meterring and tap-off from a distribution line of an electrical installation. The moulded plasticcover of the meter board is provided with two compartments, ensuring proper separation between theIncoming Service MCB and Consumer main Switch. Each Compartment is provided with separated coverwith facility for sealing or padlocking. The Unfused Tap-Off Box and Meter Board are mounted in-linedirectly on a 50 x 150 mm2 trucking, while allowing other truckings to run alongside.
Technical Data
Electrical Meter Board Type : AMP RangeSpecification : IEC 60439-1Rated Current : 40ARated Voltage : 250V 50 HzDegree of Protection : IP 30
Unfused Tap-Off Box Type : ATB RangeSpecification : IEC 60439-1Rated Voltage : 250V 50 HzDegree of Protection : IP 30Cable Connections : Incoming 3 x(25 - 95) mm2
Outgoing 3 x(6 - 25) mm2
MaterialBase for Meter Board : EG sheet steel (1.2 mm)Tap-off Box : EG sheet steel (1.2 mm)Equipment Cover : Moulded Plastic PC ABS (2.5 mm)Colour : Light Grey for Base & Tap-off Box
Dark Grey for Equipment CoverSecurity : Sealable and/or lockablePaint : Powder Coat Oven BakedFinish : Semi-gloss
Rating Incoming Consumer Type No. Order Code Price Packing Weight
(Amp) Service Main Switch 1 pc unit 1 pc
Switch kg
40 MCB 2-pole Isolator 2-pole AMP C-I-4006 SGI9690 R0620 1 2.34
Type C 6kA 40A 63 A
Unfused Tap-off Box
Branch No. Terminal Size Type No.* Code No. Price Packing Weight
1 pc unit 1 pc
kg
Incoming 3x(25-95)mm2 ATB 9525-2506 SGI 9690 R1001 1 1.76
Outgoing 3x(6-25)mm2
* To specify left or right hinge during order.
P45P45
Short Form CatalogueP46
System proM
P47
Modular DIN-Rail Components
and Isolators
• Modular DIN-Rail Components for
Protection - Isolation
• Control
• Switching
• Signalling
• Distribution
• Transformation * Information in
electrical building installation.
• Isolators single to four poles with rated
current up to 125A.
Residual Current Relay 48
Overstop System 48
Switches 16 and 25 A 49
Surge Protective Devices 50
Switch-Isolator 16... 125 A 52
Pushbuttons, Illuminated Pushbuttons, Indicator Lights 54
Latching Relays 54
Emergency Light 55
Twilight Switch 55
Overload Alarm 55
Alarm Indicators 55
Fuse Switches 56
Time Clocks 57
Programmable Electronic Timer 57
Installation Contactors 58
Bells 58
Installation Measuring Equipment with Analog Display 59
Installation Measuring Equipment with Digital Display 59
Accessories for Instruments 59
Energy Meters 61
Modular DIN-Rail Components(MDRCs)
Short Form CatalogueP48
Modular DIN-Rail Components (MDRCs)
Residual Current Relays
To protect against indirect contacts in 3-phase circuits with normal currents up to 1000 A. Mainly industrial
application (In > 100 A), wherever it is required to define sensitivity and time delay, for A.C. and pulsating
residual current.
The Overstop System
Description Ordering Details Order Code Price Packing Weight
Type No. 1 pc unit 1 pc
kg
Residual Current Relays RD1 EG 3089 1
Toroidal Transformer for Residual Current Relays
Toroidal Transformer ø35 mm TR1 EG 3097 1
Toroidal Transformer ø60 mm TR2 EG 3105 1
Toroidal Transformer ø80 mm TR3 EG 3113 1
Toroidal Transformer ø110 mm TR4 EG 3121 1
Toroidal Transformer ø210 mm TR5 EG 4160 1
Modular Toroidal Transformer TRM EG 2990 1
ø29 mm (3 modules)
Description Ordering Details Order Code Price Packing Weight
Type No. 1 pc unit 1 pc
kg
Protection for 220V & 380 electric lines
3-phrase 65 kA OVR / 365 EA 8800 1
(4 modules)
Single phrase 65 kA OVR / 165 EA 8787 1
(2 modules)
3-phrase 40 kA OVR / 340 EA 8803 1
(4 modules)
Single phrase 40 kA OVR / 140 EA 8779 1
(2 modules)
3-phrase 15 kA OVR / 315 EA 8779 1
(4 modules)
Single phrase 15 kA OVR / 115 EA 8761 1
(2 modules)
Protection for telephone and data transmission lines
48V DC telephone protection OVR / TEL EA 8229 1
10 kA (1 module)
RD1
TRM
TR..
OVR 2
P49
Modular DIN-Rail Components (MDRCs)
Switches 16...25A
Contacts Rated Power Ordering Order Code Price Packing Weight
Voltage Loss Details 1 pc unit 1 pc
VAC W Type No. kg
Control switchesRated current = 16 A
1 NO + 1 NC 250 0.96 E 221 - 11 GHE 221 1001 R0005 10 0.070
2 NO + 2 NC 250 1.92 E 221 - 22 GHE 221 1001 R0006 10 0.070
3 NO + 1 NC 400 1.92 E 221 - 31 GHE 221 1001 R0007 0.070
Rated current = 25 A
1 NO + 1 NC 250 2.26 E 222 - 11 GHE 222 1001 R0005 10 0.070
Change-over switchesRated current = 16 A
1 change-over 250 0.48 E 221 - 6 GHE 221 1001 R0008 10 0.060
2 change-over 250 0.96 E 221 - 6/2 GHE 221 1001 R0009 10 0.070
Rated current = 25 A
1 change-over 250 1.13 E 222 - 6 GHE 222 1001 R0008 10 0.060
Group switches (I-O-II, Manual-OFF-Automatic)Rated current = 16 A
1-pole 250 0.48 E 221 - 4 GHE 221 1001 R0014 10 0.060
2- pole 250 0.96 E 221 - 4/2 GHE 221 1001 R0015 10 0.070
Rated current = 25 A
1-pole 250 1.13 E 222 - 4 GHE 222 1001 R0014 10 0.60
Switch-isolatorRated current = 16 A
1 NO 250 0.48 E 221 - 10 GHE 221 1001 R0001 10 0.055
2 NO 250 0.96 E 221 - 20 GHE 221 1001 R0002 10 0.060
3 NO 400 1.44 E 221 - 30 GHE 221 1001 R0003 10 0.065
4 NO 400 1.92 E 221 - 40 GHE 221 1001 R0004 10 0.070
Rated current = 25 A
1 NO 250 1.13 E 222 - 10 GHE 222 1001 R0001 10 0.055
2 NO 250 2.26 E 222 - 20 GHE 222 1001 R0002 10 0.060
3 NO 400 3.39 E 222 - 30 GHE 222 1001 R0003 10 0.065
4 NO 400 4.52 E 222 - 40 GHE 222 1001 R0004 10 0.070
Switch-isolators with built-in pilot lamp for 220 V ACRated current = 16 A
1 NO 250 0.5 E 221 - 10 x GHE 221 1001 R0011 10 0.060
2 NO 250 1.0 E 221 - 20 x GHE 221 1001 R0012 10 0.065
3 NO 400 1.5 E 221 - 30 x GHE 221 1001 R0013 10 0.087
Rated current = 25 A
1 NO 250 1.15 E 222 - 10 x GHE 222 1001 R0011 10 0.060
2 NO 250 2.30 E 222 - 20 x GHE 222 1001 R0012 10 0.065
3 NO 400 3.45 E 222 - 30 x GHE 222 1001 R0013 10 0.087
E221-16
Short Form CatalogueP50
Modular DIN-Rail Components (MDRCs)Surge
Protective DevicesLightning Current Arrester (class B)For equalising lightning protection potential according to DIN VDE 0185 for installation category
IV according to DIN VDE 0110, Part 1.
Lightn. imp. Protection Ordering Details Order Code Price Packing Weight
current limp Level Up Type No. 1 pc unit 1 pc
kA kV kg
Blowing out75 < 3.5 Limitor M-B GH E441 0032 R0255 1 0.36
100 < 4 Limitor G-B GH E441 0012 R0255 1 0.36
(N-PE arrester)
Not blowing out25 < 4 Limitor NB-B GH E441 0042 R0255 1 0.36
50 < 4 Limitor GN-B GH E441 0022 R0255 1 0.26
(N-PE arrester)
Inductance decoupling
Rated Rated Ordering Details Order Code Price Packing Weight
current IN inductance Type Code 1 pc unit 1 pc
LN µH kg
35 15 Limitor Link GH E441 0000 R0035 1 0.52
Limitor M-B
Limitor GN-B (N-PE arrester)
Limitor Link
IEC 0664-1
P51
Modular DIN-Rail Components (MDRCs)
Surge arrester (class C)For overvoltage protection according to DIN VDE 0100 for installation category III according to
DIN VDE 01110, Part 1.
Lightn. imp. Protection Ordering Details Order Code Price Packing Weight
current limp Level Up Type No. 1 pc unit 1 pc
kA kV kg
10 < 1.3 Limitor V GH E441 0001 R0001 1 0.105
100 < 1.3 Limitor VTS GH E441 0012 R0275 1 0.112
15 < 1.5 Limitor VE GH E441 0101 R0275 1 0.110
15 < 1.5 Limitor VETS GH E441 1101 R0275 1 0.114
20 < 1.5 Limitor GE-C GH E441 0111 R0255 1 0.117
15 < 1.5 Limitor VE-E GH E440 0101 R0275 1 0.110
(plug-in unit)
15 < 1.5 Limitor VETS-E GH E440 0101 R0275 1 0.045
(plug-in unit)
20 < 1.5 Limitor GE-C-E GH E440 0111 R0255 1 0.03
(plug-in unit)
Comb busbar for class B surge arresters
Cross Length No. of Ordering Details Order Code Price Packing Weight
Section m poles Type No. 1 pc unit 1 pc
mm2 kg
16 ~0.075 4 SZ-KS 19/4 N GH V036 0875 R0051 1 0.02
16 ~0.15 8 SZ-KS 19/8 N GH V036 0875 R0052 1 0.04
16 ~0.1 57 SZ-KS 19/57 N GH V036 0875 R0053 1 0.288
SurgeProtective Devices
Limitor V
Limitor VE - E
Limitor VETS
Limitor GE - C
IEC 0664-1
Short Form CatalogueP52
Modular DIN-Rail Components (MDRCs)
Switch-isolators modular type 16...125ATo protect against unintentional direct contact and provide ON/OFF switching of loaded circuits already
protected against overcurrents and short-circuits by means of a fuse or MCB (In > 32 A).
Type Rated Rated Ordering Order Code Price Packing Weight
Current Voltage Details 1 pc unit 1 pc
Type No. kg
E240 Ranges1 NO 16 240 E 241/16 rt GJF 152 1110 R0015 10 0.080
2 NO 16 415 E 242/16 rt GJF 152 2110 R0015 5 0.175
3 NO 16 415 E 243/16 rt GJF 152 3110 R0015 3 0.270
4 NO 16 415 E 244/16 rt GJF 152 4110 R0015 2 0.270
1 NO 32 240 E 241/32 rt GJF 152 1130 R0015 10 0.080
2 NO 32 415 E 242/32 rt GJF 152 2130 R0015 5 0.175
3 NO 32 415 E 243/32 rt GJF 152 3130 R0015 3 0.270
4 NO 32 415 E 244/32 rt GJF 152 4130 R0015 2 0.270
1 NO 45 240 E 241/45 rt GJF 152 1150 R0015 10 0.080
2 NO 45 415 E 242/45 rt GJF 152 2150 R0015 5 0.175
3 NO 45 415 E 243/45 rt GJF 152 3150 R0015 3 0.270
4 NO 45 415 E 244/45 rt GJF 152 4150 R0015 2 0.365
1 NO 63 240 E 241/63 rt GJF 152 1170 R0015 10 0.085
2 NO 63 415 E 242/63 rt GJF 152 2170 R0015 5 0.180
3 NO 63 415 E 243/63 rt GJF 152 3170 R0015 3 0.275
4 NO 63 415 E 244/63 rt GJF 152 4170 R0015 2 0.370
1 NO 80 240 E 241/80 rt GJF 152 1180 R0015 10 0.085
E 241
E 242
E 243
E 244
IEC 60947-3
P53
Modular DIN-Rail Components (MDRCs)
Switch-isolators modular type 16...125ATo protect against unintentional direct contact and provide ON/OFF switching of loaded circuits already
protected against overcurrents and short-circuits by means of a fuse or MCB (In > 32 A).
Type Rated Rated Ordering Details Order Code Price Packing Weight
Current Voltage Type No. 1 pc unit 1 pc
kg
E270 Ranges1 NO 63 240 E 271/63 rt GJF 151 1170 R0015 10 0.100
2 NO 63 415 E 272/63 rt GJF 151 2170 R0015 5 0.215
3 NO 63 415 E 273/63 rt GJF 151 3170 R0015 3 0.330
4 NO 63 415 E 274/63 rt GJF 151 4170 R0015 2 0.440
1 NO 80 240 E 271/80 rt GJF 151 1180 R0015 10 0.105
2 NO 80 415 E 272/80 rt GJF 151 2180 R0015 5 0.220
3 NO 80 415 E 273/80 rt GJF 151 3180 R0015 3 0.335
4 NO 80 415 E 274/80 rt GJF 151 4180 R0015 2 0.450
1 NO 100 240 E 271/100 rt GJF 151 1190 R0015 10 0.105
2 NO 100 415 E 272/100 rt GJF 151 2190 R0015 5 0.220
3 NO 100 415 E 273/100 rt GJF 151 3190 R0015 3 0.335
4 NO 100 415 E 274/100 rt GJF 151 4190 R0015 2 0.450
1 NO 125 240 E 271/125 rt GJF 151 1191 R0015 10 0.105
2 NO 125 415 E 272/125 rt GJF 151 2191 R0015 5 0.220
3 NO 125 415 E 273/125 rt GJF 151 3191 R0015 3 0.335
4 NO 125 415 E 274/125 rt GJF 151 4191 R0015 2 0.450
E 271
E 272
E 273
E 274
IEC 60947-3
Short Form CatalogueP54
Modular DIN-Rail Components (MDRCs)
Pushbuttons and Indicator LightsRated current for pushbuttons and illuminated pushbuttons = 16 A, rated voltage = 250 V AC
Type Power Ordering Details Order Code Price Packing Weight
Loss Type No. 1 pc unit 1 pc
W kg
Pushbuttons 1NO contact + 1 NC contactGrey 0.96 E 225 - 11 B GHE 225 1001 R0001 10 0.055
Red 0.96 E 225 - 11 C GHE 225 1001 R0002 10 0.055
Green 0.96 E 225 - 11 D GHE 225 1001 R0003 10 0.055
Yellow 0.96 E 225 - 11 E GHE 225 1001 R0004 10 0.055
Black 0.96 E 225 - 11 F GHE 225 1001 R0005 10 0.055
Blue 0.96 E 225 - 11 G GHE 225 1001 R0006 10 0.055
Illuminated pushbuttons 1 NO + NC contact, with glow lamp E 10/230 V AC
Clear 1.5 E 227 - 11 B GHE 227 1001 R0011 10 0.055
Red 1.5 E 227 - 11 C GHE 227 1001 R0012 10 0.055
Green 1.5 E 227 - 11 D GHE 227 1001 R0013 10 0.055
Yellow 1.5 E 227 - 11 E GHE 227 1001 R0014 10 0.055
Blue 1.5 E 227 - 11 G GHE 227 1001 R0015 10 0.055
Indicators light with glow lamp E 10/220 V ACClear 1.03 E 229 - B GHE 229 1001 R0001 10 0.045
Red 1.03 E 229 - C GHE 229 1001 R0002 10 0.045
Green 1.03 E 229 - D GHE 229 1001 R0003 10 0.045
Yellow 1.03 E 229 - E GHE 229 1001 R0004 10 0.045
Blue 1.03 E 229 - G GHE 229 1001 R0006 10 0.045
Latching RelaysOperating voltage Uc = 24 V/50 Hz
Contacts Power Ordering Details Order Code Price Packing Weight
Loss Type No. 1 pc unit 1 pc
W kg
1 NO 2 (6) E251 - 24 GHE 251 1001 R0101 10 0.104
2 NO 4 (8) E252 - 24 GHE 252 1001 R0201 10 0.111
1 NO + 1 NC 2 (6) E256 - 24 GHE 256 1001 R0111 10 0.111
4 NO 6 (16) E254 - 24 GHE 254 1001 R0401 5 0.210
2 NO (Series) 2 (8) E255 - 24 GHE 255 1001 R0201 10 0.111
Operating voltage Uc = 230 V/50 Hz
1 NO 2 (6) E251 - 230 GHE 251 1001 R0106 10 0.104
2 NO 4 (8) E252 - 230 GHE 252 1001 R0206 10 0.109
1 NO + 1 NC 2 (6) E256 - 230 GHE 256 1001 R0116 10 0.109
4 NO 6 (16) E254 - 230 GHE 254 1001 R0406 5 0.210
2 NO (Series) 4 (8) E255 - 230 GHE 255 1001 R0206 10 0.109
- For calculation of the power loss, wattage of the filament or glow lamp used has to be taken into consideraton.
- Filament lamps only permissible up to max. 2 W
- Spare parts available on request
- Values given in brackets = power loss at permanent excitation.
- Operating voltage Uc = 8V/50Hz & Uc = 12V/50Hz available on request.
- Latching relays with electronic control are available on request.
E225
E 227
E 229
E 256
P55
Modular DIN-Rail Components (MDRCs)
Emergency LightAutomatically provides light to the consumer unit during a power failure so that user can operate on the
consumer units or distribution board. Install mainly in small / medium size distribution boards.
Description Ordering Details Order Code Price Packing Weight
Type No. 1 pc unit 1 pc
kg
Emergency light LE - 230 GHV021 2966 R001 1 0.13
Twilight SwitchAllows light equipment to turn ON/OFF according to presettable level of the environmental light intensity,
working in combination with a proper light sensor. Use mainly in street lighting,
entrance and courtyards.
Twilight switch + TWS - 1 EG 5738 1 0.270
light sensor
light sensor LS - 1 EG 5746 1 0.050
Overload AlarmTo prevent the tripping of hte electricity board main switch. It signals the approaching of the actual
power consumption of an installation to the maximum permitted value, by setting a proper consumption
alarm threshold.
Overload alarm- 4 kW RMC EG 2982 1
(2 modules)
Overload alarm- 6 kW RMC - 6 EG 4046 1
(2 modules)
Alarm IndicatorsTo transmit optical and acoustic signal. In case of malfunction, flashing and beep signal are sent out.
Alarm indicator E228-WM GHE 228 1001 K0001 1 0.070
LE
TWS
RMC
Short Form CatalogueP56
Modular DIN-Rail Components (MDRCs)
E931...
E933...
E31...
No. of Rated Ordering Details Order Code Price Packing Weight
poles Current Type No. 1 pc unit 1 pc
In A kg
500 V AC (for 8.5 x 31.5 fuses up up to 20A)
1 1 E931/20 EA1915 1 0.081
1+NA 1 E931N/20 EA2913 1 0.094
2 2 E932/20 EA1931 1 0.162
3 3 E933/20 EA1949 1 0.244
3+NA 3 E933N/20 EA2921 1 0.257
500 V AC (for 10.3 x 38 fuses up up to 32A)
1 1 E931/32 EA2012 1 0.081
1+NA 1 E931N/32 EA2939 1 0.094
2 2 E932/32 EA2038 1 0.162
3 3 E933/32 EA2046 1 0.244
3+NA 3 E933N/32 EA2947 1 0.257
Coupling kit E930 Kit EA2111
for switch-fuses
20A and 32A
500 V AC - 660V AC 40A (for 14 x 51 fuses up up to 50A)
1 1.5 E31/50 EF9863 1 0.130
1+NA 3 E31N/50 EF9871 1 0.250
2 3 E32/50 EF9889 1 0.260
3 4.5 E33/50 EF9897 1 0.260
3+NA 6 E33N/50 EF9905 1 0.520
500 V AC (for 22 x 58 fuses up up to 125A)
1 2 E31/125 EF9913 1
1+NA 4 E31N/125 EF9921 1
2 4 E32/125 EF9939 1
3 6 E33/125 EF9947 1
3+NA 8 E33N/125 EF9954 1
P57
Modular DIN-Rail Components (MDRCs)
ETS
STT-117 N
Electro-mechanical time switch
Description Ordering Order Code Price Packing Weight
Details Type No. 1 pc unit 1 pc
kg
Daily programmer without reserve ETS 1 EA 5114 1
(3 modules)
Daily programmer with reserve (72h) ETS 1/R EA 5122 1
(3 modules)
Weekly programmer with reserve (72h) ETS 7/R EA 5130 1
(3 modules)
Programmable time switcheswith micro-processor-controlled electronics
Contacts Memory Power Ordering Order Code Price Packing Weight
Units Loss Details Type No. 1 pc unit 1 pc
W kg
1-channel one-day time switch with 24 h programfor 7 switch-on and 7 switch-off times. ( 14 memory locations).
1 NO 14 6 STT-111N GHV 021 0859 R0021 1 0.17
1-channel one-day/one-week time switch with 24 h/7 d programfor 7 switch-on and 7 switch-off times ( 14 memory locations) freely assignable.
1 NO 14 6 STT-117 N GHV 021 0859 R 0022 1 0.13
1-channel one-day/one-week time switch with 24 h/7 d programand random switching36 memory location. Individualised blocks.
1 W 36 6 STT-127 N GHV 021 0859 R 0023 1 0.13
2-channel one-day/one-week time switch with 24 h/7 d program36 memory locations freely assignable to channel 1 or 2. Indvidualised blocks.
2 W 36 5 STT-227N GHV 021 0859 R 0024 1 0.16
Short Form CatalogueP58
Modular DIN-Rail Components (MDRCs)
Installation Contactors
Contacts Rated Ordering Details Order Code Price Packing Weight
Contact Type No. 1 pc unit 1 pc
In A kg
2 NO 20 ESB 20-20/.. GHE 321 1102 R000 ❑ 10 0.2
2 NC 20 ESB 20-02/.. GHE 321 1202 R000 ❑ 10 0.2
1 NO + 1 NC 20 ESB 20-11/.. GHE 321 1302 R000 ❑ 10 0.2
4 NO 24 ESB 24-40/.. GHE 329 1102 R000 ❑ 10 0.28
4 NC 24 ESB 24-04/.. GHE 329 1202 R000 ❑ 10 0.28
2 NO + 2 NC 24 ESB 24-22/.. GHE 329 1302 R000 ❑ 10 0.28
3 NO + 1 NC 24 ESB 24-31/.. GHE 329 1602 R000 ❑ 10 0.28
4 NO 40 ESB 40-40/.. GHE 349 1102 R000 ❑ 3 0.45
4 NO 63 ESB 63-40/.. GHE 369 1102 R000 ❑ 3 0.45
1) Add coil/voltage to type no.
2) Enter number for the rated operating voltage desired
Further coil voltages and/or
frequencies upon request.
Bell TransformersSafety single-phase transformers aimed at supplying mainly belts / buzzers and similar devices through a
very low secondary nominal voltage (< 24V). Use for door bells in residential / commercial buildings.
Description No. of Power (VA) Ordering Order Code Price Packing Weight
Modules Continuous/ Details 1 pc unit 1 pc
Intermittant Type No. kg
Single phase transformerssec. 4-8-12V 2 6/10 TM 10/12 EA 3929 1 0.28
sec. 12-24V 2 6/10 TM 10/24 EA 3937 1 0.28
sec. 4-8-12V 2 10/15 TM 15/12 EA 3945 1 0.32
sec. 12-24V 2 10/15 TM 15/24 EA 3952 1 0.32
sec. 4-8-12V 3 20/30 TM 30/12 EA 3960 1 0.56
sec. 12-24V 3 20/30 TM 30/24 EA 3978 1 0.56
Transformers with bulit-in bellssec. 12V 2 /10 TSM EA 4141 1 0.40
Short-circuit proof transformerssec. 8 2 8 TS 8/8 GHV 023 2699 R0001 5 0.355
sec. 12 2 8 TS 8/12 GHV 023 2707 R0001 5 0.355
sec. 24 2 8 TS 8/24 GHV 023 2749 R0001 5 0.277
BellsModular bells
230V AC 1 SM 1/230V GHV 021 4166 R0001 1 0.12
12V AC 1 SM 1/12V GHV 021 4158 R0001 1 0.12
Voltage VAC/50 Hz 24 42 110 230
Number ❑ ❑ ❑ ❑
1 2 4 6
ESB 20..
ESB 40..
TM..
TSM
P59
Modular DIN-Rail Components (MDRCs)
VLM 1
AMT 1
Measuring Equipment
Measuring Power Ordering Details Order Code Price Packing Weight
Range Loss Type No. 1 pc unit 1 pc
W kg
Measuring equipment with analog display, class 1.5Moving-iron measuring instruments for AC voltages ( direct measurement )
300 V AC 4 VLM 1/300 GHV 022 0515 R0001 1 0.125
500 V AC 4 VLM 1/500 GHV 022 0523 R0001 1 0.125
Moving-iron measuring instruments for alternating currents
5 A 1.2 AMT 1/5 GHV 022 0598 R0001 1 0.110
10 A AMT 1/10 GHV 022 0531 R0001 1 0.110
15 A AMT 1/15 GHV 022 0549 R0001 1 0.110
20 A AMT 1/20 GHV 022 0556 R0001 1 0.110
25 A AMT 1/25 GHV 022 0564 R0001 1 0.110
30 A AMT 1/30 GHV 022 0572 R0001 1 0.110
Transformer AMT 1/A1 GHV 022 0580 R0001 1 0.100
connection 5A
Measuring equipment with digital display, class 0.5Measuring instrument for alternating voltage ( direct measurement )
600 V 2.0 VLM - D1 GHV 022 4087 R0001 10 0.300
Measuring instrument for AC current with coding switch for selection of the measuring ranges
99.9 V 2.0 AMT - D1 GHV 022 4061 R0001 1 0.300
and 600 V
Measuring instrument for frequencies ( direct measurement )
40 - 80 Hz 2.0 FRZ - D1 GHV 022 4103 R0001 1 0.300
Short Form CatalogueP60
Modular DIN-Rail Components (MDRCs)
Accessories for Instruments
Description Ordering Order Code Price Packing Weight
Details 1 pc unit 1 pc
Type No. kg
Current transformers / wound primaryIprim 1 A : class 0. 5 - 3 VA, class 1 - 6 VA CTR 0/1 EG 750 2
Iprim 5 A : class 0. 5 - 3 VA, class 1 - 6 VA CTR 0/5 EG 751 0
Iprim 10 A : class 0. 5 - 3 VA, class 1 - 6 VA CTR 0/10 EG 752 8
Iprim 15 A : class 0. 5 - 3 VA, class 1 - 6 VA CTR 0/15 EG 753 6
Iprim 20 A : class 0. 5 - 3 VA, class 1 - 6 VA CTR 0/20 EG 754 4
Iprim 25 A : class 0. 5 - 3 VA, class 1 - 6 VA CTR 0/25 EG 755 1
Iprim 40 A : class 0. 5 - 3 VA, class 1 - 6 VA CTR 0/40 EG 756 9
Iprim 50 A : class 0. 5 - 3 VA, class 1 - 6 VA CTR 0/50 EG 757 7
Iprim 60 A : class 0. 5 - 3 VA, class 1 - 6 VA CTR 0/60 EG 758 5
Iprim 80 A : class 0. 5 - 3 VA, class 1 - 6 VA CTR 0/80 EG 759 3
Iprim 100 A : class 0. 5 - 3 VA, class 1 - 6 VA CTR 0/100 EG 750 1
Current transformers / through primary ( cable ø 21c mm )Iprim 40 A : class 3 - 1.5 VA, class 1 - 1 VA CTR 1/40 EG 761 9
Iprim 50 A : class 3 - 2 VA, class 1 - 1 VA CTR 1/50 EG 762 7
Iprim 60 A : class 3 - 2.5 VA, class 1 - 1 VA CTR 1/60 EG 763 5
Iprim 80 A : class 3 - 4 VA, class 1 - 1.5 VA CTR 1/80 EG 764 3
Iprim 100 A : class 0.5 - 1 VA, class 1 - 2 VA CTR 1/100 EG 765 0
Iprim 150 A : class 0.5 - 3 VA, class 1 - 5 VA CTR 1/150 EG 766 8
Iprim 200 A : class 0.5 - 5 VA, class 1 - 10 VA CTR 1/200 EG 767 6
Iprim 250 A : class 0.5 - 8 VA, class 1 - 10 VA CTR 1/250 EG 768 4
Accessories for InstrumentsInterchangeable Scales for Ammeter AMT 1/A1
Measuring Power Ordering Details Order Code Price Packing Weight
Range Loss Type No. 1 pc unit 1 pc
W kg
5 A SCL 1/5 GHV 022 0614 R0001 10 0.243
10 A SCL 1/10 GHV 022 0622 R0001 10 0.243
20 A SCL 1/20 GHV 022 0630 R0001 10 0.243
30 A SCL 1/30 GHV 022 0648 R0001 10 0.243
50 A SCL 1/50 GHV 022 0655 R0001 10 0.243
75 A SCL 1/75 GHV 022 1067 R0001 10 0.243
80 A SCL 1/80 GHV 022 0663 R0001 10 0.243
100 A SCL 1/100 GHV 022 0671 R0001 10 0.243
150 A SCL 1/150 GHV 022 0689 R0001 10 0.243
200 A SCL 1/200 GHV 022 0697 R0001 10 0.243
250 A SCL 1/250 GHV 022 0481 R0001 10 0.243
300 A SCL 1/300 GHV 022 0705 R0001 10 0.243
400 A SCL 1/400 GHV 022 0838 R0001 10 0.243
500 A SCL 1/500 GHV 022 0846 R0001 10 0.243
600 A SCL 1/600 GHV 022 1745 R0001 10 0.243
800 A SCL 1/800 GHV 022 0853 R0001 10 0.243
1000 A SCL 1/1000 GHV 022 0861 R0001 10 0.243
SCL..
P61
Modular DIN-Rail Components (MDRCs)
Accessories for Instruments
Description Ordering Order Price Packing Weight
Details Code 1 pc unit 1 pc
Type No. kg
Modular current transformers ( depth 58 mm ) 29 mm - secondary current 5 APrimary current : 40 A - class 3 VA - 1 TRF M/40 EG 289 1
Primary current : 60 A - class 1 VA - 2 TRF M/60 EG 290 9
Primary current : 100 A - class 0.5 VA - 2 TRF M/100 EG 291 7
Primary current : 150 A - class 0.5 VA - 3 TRF M/150 EG 292 5
Primary current : 250 A - class 0.5 VA - 4 TRF M/250 EG 293 3
Primary current : 400 A - class 0.5 VA - 6 TRF M/400 EG 294 1
Primary current : 600 A - class 0.5 VA - 8 TRF M/600 EG 295 8
Current transformers / through primary ( bar 30x10 mm, cable ø 22 mm )Iprim 100 A : class 1 - 1.5 VA CTR 3/100 EG 769 2
Iprim 150 A : class 0.5 - 1.5 VA, class 1 - 2.5 VA CTR 3/150 EG 770 0
Iprim 200 A : class 0.5 - 2 VA, class 1 - 3 VA CTR 3/200 EG 771 8
Iprim 250 A : class 0.5 - 2.5 VA, class 1 - 3.5 VA CTR 3/250 EG 772 6
Iprim 300 A : class 0.5 - 6 VA, class 1 - 6 VA CTR 3/300 EG 773 4
Iprim 400 A : class 0.5 - 10 VA, class 1 - 12 VA CTR 3/400 EG 774 2
Iprim 500 A : class 0.5 - 10 VA, class 1 - 12 VA CTR 3/500 EG 775 9
Iprim 600 A : class 0.5 - 10 VA, class 1 - 12 VA CTR 3/600 EG 776 7
Energy meter EMT
Description Ordering Details Order Code Price Packing Weight
Type No. 1 pc unit 1 pc
kg
Single-phase energy meter EMT 3 EG 5787 1
(3 modules)
Other ratings & ranges available on request.
EMT 3
System proM
Short Form CatalogueP62
Accessories forConnection and Installation
P63
Acessories for
Connection and Installation
For easier mounting and wiring of all
components of the ABB System proM
range in consumer units, distribution
boards, switchboards or as single units, a
wide range of useful aides is available:
• Terminal covers for 1 to 8 modules.
• Busbars for single, double, three and
four-poles connections.
• Terminals up to 50 mm2 cross-section
• Blanking plates, gland plates, barriers,
end clamps.
• Flange mounting sets.
• DIN-mounting rails (omega rails).
• Common padlocking device for MCBs,
RCDs and isolators.
Busbar & Comb-Busbar Blocks 64
Terminal for Feeding of Busbar Blocks 64
Marking Labels 65
Locking Devices 65
Blanking Plate 65
Filler Pieces 65
Neutral Terminal 65
Spring Support 65
Short Form CatalogueP64
Accessories for Connection and Installation
Busbar and Comb-Busbar BlocksBusbar blocks with all round protection against accidental contact with life parts for
all round protected MCBs with dualfunction box terminal.
Cross Length Number Ordering Order Code Price Packing Weight
section mm of Details Type No. 1 pc unit 1 pc
mm2 poles kg
Universal comb busbar
for MCBs : 1 pole
Supply : 1 phase
12 207 12 x 1 SZ-KS 1/12 GJI 2 322 322 R0001 100 0.015
12 988 56 x 1 SZ-KS 1/56 GJI 2 322 322 R0002 50 0.073
24 207 12 x 1 SZ-KS 2/12 GJI 2 322 322 R0003 100 0.031
24 988 56 x 1 SZ-KS 2/56 GJI 2 322 322 R0004 50 0.145
36 988 56 x 1 SZ-VB 45/32 GJI 2 322 148 R0001 50 0.28
Comb-busbar blocks
for MCBs : 1 or 3 poles
Supply : 3 phase
16 213 4 x 3 SZ-PSB 11 N GHL 520 1916 R0003 30 0.2
16 1065 20 x 3 SZ-PSB 12 N GHL 520 1916 R0004 10 1.0
for MCBs : 1 poles + NA or 2 poles
Supply : 1 phase + N
10 213 6 x 2 SZ-PSB 53 N GHV 036 0874 R0031 30 0.078
10 1035 29 x 2 SZ-PSB 54 N GHV 036 0874 R0032 10 0.403
16 213 6 x 2 SZ-PSB 55 N GHV 036 0874 R0033 30 0.106
16 1035 29 x 2 SZ-PSB 56 N GHV 036 0874 R0034 10 0.534
for MCBs : 3 poles + NA or 4 poles
Supply : 3 phase + N
16 213 3 x 4 SZ-PSB 63 N GHV 036 0874 R0041 30 0.156
16 1065 15 x 4 SZ-PSB 64 N GHV 036 0874 R0042 10 0.884
End caps for busbar blocks with all round protection
against accidental contact with life parts
PSB-END 1 GHL 520 1921 R0001 50
PSB-END 2 GHL 520 1921 R0002 50
PSB-END 3 GHV 036 1325 R1 50
Connection Terminals for feeding of busbar blocksAll-round protection against accidental contact with live parts acc. to DIN VDE 0106 T 100 (VBG 4).
The single-pole terminals can be added to multi-pole terminal.
35 SZ-ESK 1 GHV 036 0872 R0003 10/250 0.022
End caps:
1) PSB - END 1
2) PSB - END 2
End caps:
PSB - END 3
P65
Accessories for Connection and Installation
Labelling AccessoriesDescription Ordering Details Order Code Price Packing Weight
Type No. 1 pc unit 1 pc
pcs kg
Marking Labelsconsisting of transparent label carrier and marked or unmarked etiquettes which can be plugged in can
be used for switches, pushbuttons, indicator lights, latching relays, installation relays as well as MCB’s,
RCCB’s and SIGMA-i-bus EIB components.
Label carrier snal-on fixing ST GHS 210 6641 P0002 10
Description label ST-E GHV 021 0895 P0010 1 sheet
1 sheet = 250 pcs
Locking device for MCBs, RCDs and Switch Isolatorsfor prevention of single- or multi-pole MCBs against dangerous switching on or unauthorized switching-
off. For padlock with diameter max. 4 mm and lock width max. 17 mm.
Adapter SA 1 GJF 110 1903 R0001 10 0.02
Padlock with 3 keys SA 2 GJF 110 1903 R0002 10 0.004
Adapter incl. padlock SA 3 GJF 110 1903 R0003 10 0.05
with 3 keys
Blanking plates for covers with 1 to 3 mm thickness, 1 module = 18 mm
Cutout Height Cover Width
46 mm 213 SZ-BP12 GJF 110 1902 R0008 100 0.028
Filler pieceSZ-FST2 GHL 530 1908 R0002 25 0.010
Spring supportSZ-FDT2 GHL 530 1908 R0005 25 0.002
Neutral terminal16 KLD 16 GJF 199 0931 R0002 10 0.020
50 KLD 50 GJF 199 0931 R0003 10 0.050
Label carrier snap-on fixing
Padlocking Devices
Blanking Plates
System proM
Short Form CatalogueP66
Miniature Circuit Breakers 68
Residual Current-Operated Devices 70
Enclosures 72
Modular DIN-Rail Components 74
P67
Selection Tables
Short Form CatalogueP68
Selection TableMiniature Circuit Breakers
Application: To control and protect against circuit overloads and short-circuit current in
• domestic installations
• commercial and industrial electrical distribution systems.
(1) Frequency affects only electromagnetic trips. Other frequencies are also possible with some change in tripping characteristics. Data available in technical catalogues.
(2) Breaking capacities as per other international standards upon request/available in technical catalogues.
Technical Data S230 S250 S270
Standard IEC 60898 IEC 60898 IEC 60898Specifications: IEC 60947-2 IEC 60947-2 IEC 60947-2
NEMA AB-1 NEMA AB-1 NEMA AB-1BS EN 60898 BS EN 60898 BS EN 60898
Tripping B,C B,C B,C,KCharacteristics:
No. of Poles: 1, 2, 3, 1 + NA, 3 + NA 1, 2, 3, 4, 1 + NA, 3 + NA 1, 2, 3, 4, 1 + NA, 3 + NA
Rated Current In: 6 - 63A 6 - 63A for S250 B 6 - 63A for S270B1 - 63A for S250 C 0.5 - 100A for S270C
0.5 - 63A for S270K
Rated Voltage: InSingle Pole 230 / 400V a.c 230 / 400V a.c 230 / 400V a.cMulti Pole 400V a.c 400V a.c 400V a.cDC - 1 Pole - 60V -- 60V --DC - 2 Pole - 110V -- 110V --
Frequency (1): 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz
Rated Rupturing 3kA acc. IEC 60898 6kA acc. IEC 60898 S270 B,C 10kACapacity: 4.5kA acc. IEC 60947-2 10kA acc. IEC 60947-2 S270 K 6kA
10kA acc. NEMA AB-1 22kA acc. NEMA AB-1 acc. IEC 60898
Mech. Service Life; 20,000 20,000 20,000
Degree of IP20 IP20 IP20Protection:
Contact Position - OFF = Green -Flag Indication: ON = Red
Trip Position - - -Indication:
Connection 0.75mm2 - 25mm2 0.75mm2 - 25mm2 0.75mm2 - 25mm2
35mm2 (50A, 63A) with solid or flexible conductors. with solid or flexible conductors.when no busbar is connected. Box terminals on top. 50mm2 for 80/100A.
Combi terminals on top and bottom. Combi terminals on bottom. Box terminals on and top.Combi terminals on bottom
Mounting Snap-on fixing on standard Snap-on fixing on standard Snap-on fixing on standardprofile rails EN50022 or profile rails EN50022 or profile rails EN50022 or
screw fixing on mounting plate. screw fixing on mounting plate. screw fixing on mounting plate.
P69
S280
IEC 60898IEC 60947-2NEMA AB-1BS EN 60898
B,C,D, K/ZUC-B / UC-K / UC-Z
1, 2, 3, 4, 1 + NA, 3 + NA
6 - 63A for S280 B0.5 - 63A for S280 C
0.2 - 63A for S280K, Z
230 / 400V a.c400V a.c
60V -- S280UC 220V -110V -- S280UC 440V -
162/3 - 60 Hz
From 10kA to 25kAacc. IEC 60898
20,000 up to 32 A10,000 above 32 A
IP20
OFF = GreenON = Red
Middle
0.75mm2 - 25mm2
with solid or flexible conductors.Combi terminals on top and bottom.
Snap-on fixing on standardprofile rails EN50022 or
screw fixing on mounting plate.
S500 B,C,D
IEC 60898IEC 60947-2
UL 1077
B,C,D,K
1, 2, 3, 3 + N, 3 + NA, 4
0.1 - 45A (adjustable) for K only6 - 63A (non-adjustable)
690V a.c---
16 2/3 - 60 Hz
25kA acc. IEC 60898up to 50kA acc. IEC 60947-2
20,000
IP20
OFF = GreenON = Red
Middle
1mm2 - 25mm2
Snap-on fixing on standardprofile rails EN50022 or
screw fixing on mounting plate.
S 700
DIN VDE 0645 and 0660Part 100, 101 and 102
E sel, K sel
1, 2, 3, 4
10 to 100 A
230/400V a.c---
50 - 60 Hz
25kA at 230/400V a.c
10,000
IP20
OFF = GreenON = Red
-
50mm2 for all kindsof conductors.
Up to 70 mm forstranded conductors.
See technical cataloguefor details.
Short Form CatalogueP70
Selection TableResidual Current-operated Devices (without overcurrent protection)
Technical Data
StandardSpecifications:
Rated Current In:
Rated ResidualOperatingCurrent I∆n:
No. of Poles:
TrippingCharacteristics:
Tripping Range:
Short-Circuitwithstand Capacity:
Rated Voltage Un:
Max. OperatingVoltage UB Max.:
Frequency:
Life Expectancy:
Mounting:
RatedRupturing Capacity:
AmbientTemperature:
Contact PositionIndicator:
Cable cross sectionBottom:
Top:
Application: 1) To protect people against electric shock resulting from direct & indirect contact with live parts when
there is an earth fault current.
2) To protect people and properties against fire hazards due to earth fault current.
F 360 F 370 F 660
IEC 61008 IEC 61008 IEC 61008BS EN 61008 BS EN 61008 BS EN 61008
32, 40, 63A 16, 25, 40,63A 80, 100, 125A
30,100,300mA 10,30,100,300500mA(4 poles only)
2 and 4 2 and 4 2 and 4
- - -
0.5 to 1.0 I∆n 0.5 to 1.0 I∆n 0.5 to 1.0 I∆n0.11 to 1.4 I∆n
6000A in combination 6000A in combination 10,000A in combinationwith S700 MCB E63A with S700 MCB E63A with S700 MCB E100A
or fuse of gL 63A. or fuse of gL 63A. or fuse of gL 100A.
2 pole 230V ~ 2 pole 230V ~ 2 pole 230V ~4 pole 230/400 ~ 4 pole 230/400 ~ 4 pole 230/400 ~
Un + 10% Un + 10% Un + 10%
50 - 60 Hz 50 - 60 Hz 50 - 60 Hz
At least 5000 operations At least 5000 operations At least 5000 operations
Snap-on to DIN rail Snap-on to DIN rail Snap-on to DIN railEn 50 022, 35mm En 50 022, 35mm En 50 022, 35mm
- - -
-5˚C to +55˚C -25˚C to +55˚C -5˚C to +55˚C
- - according toIEC 73OFF = Green, ON = Red
Combi - terminals with M5 Combi - terminals with M5 Combi - terminals with M5screw suitable for flexible and screw suitable for flexible and screw suitable for flexible and
solid conductors from solid conductors from solid conductors from1-25mm2 1-25mm2 1.5-50mm2
P71
Residual Current-operated Devices (without overcurrent protection)
F 500 C,D F 500 K GS 251 S
IEC 60947-2/ IEC 60947-2/ IEC 61009IEC 61009 IEC 61009 BS EN 61009
10 - 63A 0.28 ...... 45A (adjustable) 6 ...... 40A
10, 300mA 10, 30, 300mA 10, 30mA
2 and 4 3 and 4 1P + N
C, D K B, C
0.5 to 1.0 I∆n 0.5 to 1.0 I∆n 0.5 to 1.0 I∆n0.1 to 1.4 I∆n 0.1 to 1.4 I∆n
- - 6 kA acc to IEC 61008
2 pole 230V ~ 2 pole 230V ~ 230V ~3, 4 pole 230/400 ~ 4 pole 230/400 ~
Un + 10% Un + 10% Un + 10%
45 - 60 Hz 45 - 60 Hz 50 - 60 Hz
At least 5000 operations At least 5000 operations At least 5000 operations
Snap-on to DIN rail Snap-on to DIN rail Snap-on to DIN railEn 50 022, 35mm En 50 022, 35mm En 50 022, 35mm
Icu = 50kA Icu = 50kA -
-5˚C to +55˚C -25˚C to +55˚C -5˚C to +55˚C
- - -
Up to 50mm2 flexible Up to 50mm2 flexible 25mm2 flexibleconductors with ferrules/lugs conductors with ferrules/lugs conductors
Short Form CatalogueP72
Selection TableEnclosures
Material Plastic Metalclad
Degree of Protection IP 30 IP40 IP40
Flaps Without flap Plastic flap Plastic flap Steel flap
Type of mounting surface surface recessed surface flush surface flush
No. of Modules
1 SPE 1/M SPE F1 - - - - -
1 of 2 SPE 1-2 - - - - - -
2 SPE 2 SPE F2 - - - - -
3 of 4 SPE 3-4 - - - - - -
4 SPE 4 - - - - - -
7 - SCP 07S SCP 07R SCC 07S SCC 07F SCS 07S SCS 07F
10 - SCP 10S SCP 10R SCC 10S SCC 10F SCS 10S SCS 10F
14 - SCP 14S - - - - -
16 - SCP 16S SCP 16R SCC 16S SCC 16F SCS 16S SCS 16F
20 - SCP 20S SCP 20R SCC 20S SCC 20F SCS 20S SCS 20F
Application:To protect the user against contact
with live parts and to provide a
protective and stylish solution to
house unsightly cables and wiring.
Distribution Boards - Type B, TPN Note to the Distribution Boards:
No. of ways Surface mount with door Please indicate the type of incoming devices by replacing ** by the following
4 SDB-DB 504**
6 SDB-DB 506** • MS/100 : (Switch isolators 100A)
8 SDB-DB 508** • MC/100 : (MCCBs 100A)
12 SDB-DB 512** • MX : (DIN-Rail)
16 SDB-DB 516** • CL : (For connection with cabke plugs)
Standards: IEC 60439-1 and 60439-3
Product details available on request.
Specifications subject to change without prior notices.
P73
Selection TableEnclosures
Material Plastic
Degree of Protection IP 55 IP65
Flaps Plastic flap Plastic flap
Type of mounting surface surface
No. of Modules
2 - 12742
4 12644 12744
6 12646 -
8 - 12748
10 12650 -
12 - 12752
20 12652 -
24 - 12754
36 - 12756
54 - 12758
Short Form CatalogueP74
Selection TableModular DIN-Rail Components (MDRCs)
P75
Selected Product Range Type Code Features & Functions
E441SAT
E240E270
E225, E227, E229
E228 - WM
LE
STT
ETS
E232
E250
E234
ESB
TM, TSM, TS
HMT, E233
AMT
VMT
LIMITOR V SURGE ARRESTER
ISOLATOR FOR 63, 80 & 100A
SWITCHES, PUSH-BUTTONINDICATOR LIGHTS
ALARM INDICATIOR
EMERGENCY LAMP FORDISTRIBUTION PANELS
DIGITAL TIME SWITCH
PROGRAMMABLE TIME SWITCH
STAIRCASE TIMER
LATCHING RELAY
TIME DELAY RELAY
MINI CONTACTOR
BELL TRANSFORMER
HOUR COUNTER
ANALOGUE AMMETER
DIGITAL VOLTMETER
• Protection against lightning strikes & switching transientson the power supply system
• Modular design• Built-in monitoring device• Visual detect indicator• Remote signalling contact
• High fault current withstands up to 25 kA• Fulfils main switch & isolator specifications• Provision for interconnection with S2 mcbs & F3 residual
current-operated circuit breakers
• High contact reliability• Double-break contacts• High fault current rating
• With optical & acoustic signal
• Switches on automatically in the event of power failure &goes off again when the power returns
• Operating time: 45 min• Charging time : 12 hours
Programmable Digital time switch• 24h / 7day programs• Single & dual-channel versions• 8, 12, 24 & 42 command memories• power reserve for 250h
• With & without power reserve• Visual operating indicator• 1 minute setting accuracy Summer time/
winter time correction
• Closing and subsequent opening of a contact at the end ofa predefined time delay
• For ON/OFF switching of low power circuits by remoteimpluse-E260 signals
• Multifunctional time relay; selective function & timeswitches
• 2 & 4 Pole from 20 to 63A• Minimum switching noise due to new d.c. armature• Absolutely no hum• Provision for adding 2 pole auxiliary contacts
• Low voltage supply of belts, gongs, intercoms & buzzers
• For registration of working processes• Counting capacity 100,000 hours
• Direct analogue ammeter from 10mA to 30A
• Direct digital voltmeter from 0 to 600V
System proM
Short Form CatalogueP76
Tripping Characteristics &Dimension Drawings
Tripping Characteristics 78
Miniature Circuit Breakers 79
Enclosures & Distribution Board 80
Modular DIN-Rail Components 89
P77
Short Form CatalogueP78
Tripping CharacteristicsMCBs Type B/C/K
Tripping Characteristics Bacc. to IEC 60898
Tripping Characteristics Cacc. to IEC 60898
Tripping Characteristics Kacc. to DIN VDE 0660. Part 104
In = 0, 5 ... 63A
P79
Dimension DrawingsMiniature Circuit Breakers
MCBs S230 S250 S270 S280
RCCBs F360 F370 F390 F660
RCBOs DS 651 GS 251S
All dimensions in mm.
DS 651 GS 251S
Short Form CatalogueP80
SCS .. FSCS .. S
SCC .. FSCC .. S
Dimension DrawingsEnclosures
Consumer units (BS) SC RANGE
SCP .. R
All dimensions in mm.
Type SCP 07 S SCP 10S SCP 14 S SCP 16 S SCP 20 S
Dim.
A 215 269 338 374 446
B 129 183 252 288 380
C 196 250 319 355 427
Type SC. 07 SC. 10 SC. 16 SC. 20
Dim.
A 124 178 283 355
B 203 257 362 434
C 133 187 292 364
D 124 178 283 355
E 176 230 335 407
F 203 257 362 434
P81
Dimension DrawingsEnclosures
Terminal covers SPE Range All dimensions in mm.
SPE 1 SPE 1-2 SPE 3-4
Terminal cover IP30
SPE F1 SPE F2
Terminal cover IP40
Short Form CatalogueP82
Dimension DrawingsEnclosures
All dimensions in mm.IP55
B
H 156
206
B
85.549.5
45.5
B
H 298
226
45.5B
H 160
105
P
85.5
49.5
45.5
B
H 160
144
45.5
P
85.5
49.5
20 modules 4 modules
6 modules 10 modules
IP55 - 12690 IP55 - 12652
P83
Dimension DrawingsEnclosures
All dimensions in mm.IP 65
B
110
110
P
H 90
164 42
B
87.5
87.5
P
H 110
37.5
P B
P
164 42
122.5
240H
122.5
122
2/2 modules 12 modules 24 modules
8 modules 4 modules
36 modules 54 modules
Short Form CatalogueP84
Dimension DrawingsEnclosures - Distribution Boards
Type A TPN Distribution Boards & Type B Distribution Boards All dimensions in mm.
Type B Distribution Boards
SDB-DD 504/504 MX is similar in dimension to SDB-DB 508 MX
SDB-DD 506/506 MX is similar in dimension to SDB-DB 512 MX
SDB-DD 508/504 MX is similar in dimension to SDB-DB 512 MX
SDB-DH 512 CL is similar in dimension to SDB-DB 508 MX
SDB-DH 518 CL is similar in dimension to SDB-DB 512 MX
* For flush mounting, add 25 mm all round.
No. of A* B*(SDB-DB5 ...) C D(SDB-DB5 ...)
Ways CL MS/100 MC/100 MX CL MS/100 MC/100 MX
4 380 450 450 550 450 272 342 342 442 342
6 380 550 550 550 550 272 442 442 442 442
8 380 650 650 650 650 272 542 542 542 542
12 380 750 750 750 750 272 642 642 642 642
16 380 750 - - 272 642 - - -
P85
Dimension DrawingsEnclosures - Distribution Boards
Side Extension Boxes (with hinged doors) All dimensions in mm.
Type No. A* B* C D
SDB-SEB 2 380 450 272 342
SDB-SEB 3 380 650 272 542
SDB-SEB 4 380 750 272 642
Top/Bottom Extension Boxes (with steel flaps)
Top/Bottom Extension Boxes (without gland plates and without steel flaps)
Type No. A* B* C D E
SDB-EBF 2 380 200 272 100 377
Type No. A* B* C D
SDB-EBO 2 380 200 272 100
SDB-EBO 5 380 300 272 200
SDB-EBO 8 380 400 272 300
* For flush mounting, add 25 mm all round.
Short Form CatalogueP86
Dimension DrawingsEnclosures - Distribution Boards
SDB-BA4 B3 (8 ways)
SDB-BA4 B1 (4 ways)
SDB-BA4 B2 (6 ways)
P87
Dimension DrawingsEnclosures - Distribution Boards
Type B Busbar Assemblies All dimensions in mm.
SDB-BA4 B5 (16 ways)
SDB-BA4 B4 (12 ways)
Short Form CatalogueP88
Dimension DrawingsEnclosure - Distribution Boards
Neutral Multi-terminal Bars All dimensions in mm.
Type No. No. of Terminals A
SDB-ET 12 12 176
SDB-ET 15 15 197
SDB-ET 18 18 227
SDB-ET 24 24 278
SDB-ET 36 36 406
SDB-ET 48 48 476
Earth Multi-terminal Bars
Type No. No. of Terminals A B
SDB-NT 12 12 190 -
SDB-NT 15 15 215 -
SDB-NT 18 18 241 -
SDB-NT 24 24 320 130
SDB-NT 36 36 422 181
SDB-NT 48 48 524 232
* For flush mounting, add 25 mm all round.
P89
Toroidal transformer
Type A B C D E F G H
TR1 35 100 60 110 47 70 60 30
TR2 60 100 60 110 47 70 60 30
TR3 80 150 110 160 70 70 60 30
TR4 110 150 110 160 70 70 60 30
TR5 210 300 240 300 150 135 105 50
Modular toroidal transformer TRM
(MDRCs)
Residual Current Relay RD1
All dimensions in mm.
Toroidal transformer
The OVERSTOP System
1) M 625 manual motor starter
2) Auxiliary contact block
3) Undervoltage release or remote tripping coil
Dimension Drawings
Short Form CatalogueP90
Dimension Drawings(MDRCs)
All dimensions in mm.
Limitor GE - C Limitor VETS
Limitor VELimitor V
Limitor GN-B
Limitor NB-B
Limitor G-B
Limitor M-B
Limitor LinkLimitor VTS
P91
Dimension Drawings(MDRCs)
All dimensions in mm.
Switches and Switch - Isolator
E 229/222 E 240/E 270 E 241 E 242 E 243 E 244E 271 E 272 E 273 E 274
FUSE Switches
Push Buttons andIndicator Lights
Latching Relays Emergency Light
E 225 / E 227 / E 229 E 251- E 252- E256- E 254- LE 230
50-125A
E 931
Type No. of poles Dimensions Rating A B C D E F
E31/50 1 14 x 51 50 A 101 64 26.5 45 55 44E31N/50 1 + NA 14 x 51 50 A 101 64 53 45 55 44E32/50 2 14 x 51 50 A 101 64 53 45 55 44E33/50 3 14 x 51 50 A 101 64 79.5 45 55 44E33N/50 3 + NA 14 x 51 50 A 101 64 106 45 55 44E31/125 1 22 x 58 125 A 144 68 36.2 45 59 45E31N/125 1 + NA 22 x 58 125 A 144 68 72.4 45 59 45E32/125 2 22 x 58 125 A 144 68 72.4 45 59 45E33/125 3 22 x 58 125 A 144 68 108.6 45 59 45E33N/125 3 + NA 22 x 58 125 A 144 68 144.8 45 59 45
Short Form CatalogueP92
All dimensions in mm.
Wiring Diagram Time Clocks
Bell transformer Bells, Overload Alarm
Installation Contactors
ESB
Type Width B
ESB 20 17.5 mm
ESB 24 36.0 mm
ESB 40 54.0 mm
ESB 63 54.0 mm
EH 04 8.6 mm
Measuring Instruments:Analog and Digital
AMT/VLM/MMT
SK 0191 Z91
Dimension Drawings(MDRCs)
P93
Dimension Drawings(MDRCs)
Current Transformer All dimensions in mm.
CTR 0/... CTR 1/... CTR 3/...
TRFM
Electromechanical time switches ETS Twilight switch TWS-1
Surge arresters OVR
Time Switches