ABB JOKAB SAFETY, 2TLC010004N0201 Pluto Gateway · Pluto Gateway –remote monitoring and control...

12
ABB JOKAB SAFETY, 2TLC010004N0201 Pluto Gateway Remote monitoring and control

Transcript of ABB JOKAB SAFETY, 2TLC010004N0201 Pluto Gateway · Pluto Gateway –remote monitoring and control...

Page 1: ABB JOKAB SAFETY, 2TLC010004N0201 Pluto Gateway · Pluto Gateway –remote monitoring and control June 8, 2017 Slide 3 There is no risk of unwanted changes to the Pluto system. In

ABB JOKAB SAFETY, 2TLC010004N0201

Pluto GatewayRemote monitoring and control

Page 2: ABB JOKAB SAFETY, 2TLC010004N0201 Pluto Gateway · Pluto Gateway –remote monitoring and control June 8, 2017 Slide 3 There is no risk of unwanted changes to the Pluto system. In

Pluto Gateway – remote monitoring and control

June 8, 2017 Slide 2

• Troubleshooting

• Support of local maintenance personnel

• Regularly monitoring of the condition in machines or processes

• Download PLC program

• Configuration of AS-i bus, Status bus, IDFIX etc.

Usage

Page 3: ABB JOKAB SAFETY, 2TLC010004N0201 Pluto Gateway · Pluto Gateway –remote monitoring and control June 8, 2017 Slide 3 There is no risk of unwanted changes to the Pluto system. In

Pluto Gateway – remote monitoring and control

June 8, 2017 Slide 3

There is no risk of unwanted changes to the Pluto system.

In order for a remote download or remote configuration to be carried out, a person at the Pluto system needs to approve by pressing the “K-button” on the gateway.

Cyber security

K

Page 4: ABB JOKAB SAFETY, 2TLC010004N0201 Pluto Gateway · Pluto Gateway –remote monitoring and control June 8, 2017 Slide 3 There is no risk of unwanted changes to the Pluto system. In

Gateway used for remote operation only

Pluto Gateway – remote monitoring and control

June 8, 2017 Slide 4

Gateway

- GATE-EIP- GATE-S3- GATE-MT

Pluto bus

Ethernet

Page 5: ABB JOKAB SAFETY, 2TLC010004N0201 Pluto Gateway · Pluto Gateway –remote monitoring and control June 8, 2017 Slide 3 There is no risk of unwanted changes to the Pluto system. In

Remote operation combined with field bus communication

Pluto Gateway – remote monitoring and control

June 8, 2017 Slide 5

Pluto bus

Gateway- GATE-PN, Profinet- GATE-EIP, Ethernet/IP- GATE-S3, Sercos III- GATE-MT, Modbus TCP

PLC

Ethernet

Page 6: ABB JOKAB SAFETY, 2TLC010004N0201 Pluto Gateway · Pluto Gateway –remote monitoring and control June 8, 2017 Slide 3 There is no risk of unwanted changes to the Pluto system. In

Remote operation via field bus master

Pluto Gateway – remote monitoring and control

June 8, 2017 Slide 6

Pluto bus

Gateway- GATE-PN, Profinet- GATE-EIP, Ethernet/IP- GATE-S3, Sercos III- GATE-MT, Modbus TCP- GATE-EC, EtherCAT

PLC

Ethernet

Note:

For EtherCAT this

is the only solution

Page 7: ABB JOKAB SAFETY, 2TLC010004N0201 Pluto Gateway · Pluto Gateway –remote monitoring and control June 8, 2017 Slide 3 There is no risk of unwanted changes to the Pluto system. In

Separate gateways for remote operation and fieldbus communication

Pluto Gateway – remote monitoring and control

June 8, 2017 Slide 7

Pluto bus

Separate Gatewayfor remote operation

- GATE-EIP- GATE-S3- GATE-MT

PLC

Ethernet

Field bus

Gateway for fieldbus communication- GATE-PN, Profinet- GATE-EIP, Ethernet/IP- GATE-S3, Sercos III- GATE-MT, Modbus TCP- GATE-EC, EtherCAT

Page 8: ABB JOKAB SAFETY, 2TLC010004N0201 Pluto Gateway · Pluto Gateway –remote monitoring and control June 8, 2017 Slide 3 There is no risk of unwanted changes to the Pluto system. In

Enable remote monitoring in gateway

Pluto Gateway – remote monitoring and control

June 8, 2017 Slide 8

• Remote monitoring is enabled via the PC-port of the gateway.

• Use Pluto Manager -> Tools -> Terminal window

• Type: ”remote” ....

• Select Control/Monitoring or Monitoring only.

NOTE: The selection for remote operation can never be changed via Ethernet. The reason is that it shall only be possible to enable or change by persons physically located by the system.

Gateway configuration

Page 9: ABB JOKAB SAFETY, 2TLC010004N0201 Pluto Gateway · Pluto Gateway –remote monitoring and control June 8, 2017 Slide 3 There is no risk of unwanted changes to the Pluto system. In

Pluto Gateway – remote monitoring and control

June 8, 2017 Slide 9

• Check IP address with command ”bw”

• Change or set IP address with command ”ipaddr” (for GATE-EIP, -MT and -S3)

Gateway configuration via PC-port

Page 10: ABB JOKAB SAFETY, 2TLC010004N0201 Pluto Gateway · Pluto Gateway –remote monitoring and control June 8, 2017 Slide 3 There is no risk of unwanted changes to the Pluto system. In

Pluto Gateway – remote monitoring and control

June 8, 2017 Slide 10

1. Select Network as Communication port.

2. Enter IP address for the gateway. Default port is 50100.

3. The connection can be named and stored.

4. The setup can then be selected in the list.

Pluto Manager configuration

1

2

3

4

3

Page 11: ABB JOKAB SAFETY, 2TLC010004N0201 Pluto Gateway · Pluto Gateway –remote monitoring and control June 8, 2017 Slide 3 There is no risk of unwanted changes to the Pluto system. In

Pluto Gateway – remote monitoring and control

June 8, 2017 Slide 11

GATE-EIP: ver 2.15

GATE-EC: ver 1.3

GATE-S3: ver 1.3

GATE-PN: ver 1.2

GATE-MT: ver 1.2

Pluto Manager 2.34

Software versions needed for remote monitoring and control

Page 12: ABB JOKAB SAFETY, 2TLC010004N0201 Pluto Gateway · Pluto Gateway –remote monitoring and control June 8, 2017 Slide 3 There is no risk of unwanted changes to the Pluto system. In