Aalborg Universitet Refurbishing roof systems and roof terraces … · 1 Refurbishing Roof Systems...

17
Aalborg Universitet Refurbishing roof systems and roof terraces on a major residential building complex Bunch-Nielsen, Tommy; Brandt, Erik Publication date: 2011 Document Version Early version, also known as pre-print Link to publication from Aalborg University Citation for published version (APA): Bunch-Nielsen, T., & Brandt, E. (2011). Refurbishing roof systems and roof terraces on a major residential building complex. Paper presented at NRCA International Roofing Symposium 2011, Washington D. C., United States. http://www.nrca.net/rp/technical/symposium/default.aspx General rights Copyright and moral rights for the publications made accessible in the public portal are retained by the authors and/or other copyright owners and it is a condition of accessing publications that users recognise and abide by the legal requirements associated with these rights. ? Users may download and print one copy of any publication from the public portal for the purpose of private study or research. ? You may not further distribute the material or use it for any profit-making activity or commercial gain ? You may freely distribute the URL identifying the publication in the public portal ? Take down policy If you believe that this document breaches copyright please contact us at [email protected] providing details, and we will remove access to the work immediately and investigate your claim. Downloaded from vbn.aau.dk on: September 03, 2020

Transcript of Aalborg Universitet Refurbishing roof systems and roof terraces … · 1 Refurbishing Roof Systems...

Page 1: Aalborg Universitet Refurbishing roof systems and roof terraces … · 1 Refurbishing Roof Systems and Roof Terraces on a Major Residential Building Complex Tommy Bunch-Nielsen, Danish

Aalborg Universitet

Refurbishing roof systems and roof terraces on a major residential building complex

Bunch-Nielsen, Tommy; Brandt, Erik

Publication date:2011

Document VersionEarly version, also known as pre-print

Link to publication from Aalborg University

Citation for published version (APA):Bunch-Nielsen, T., & Brandt, E. (2011). Refurbishing roof systems and roof terraces on a major residentialbuilding complex. Paper presented at NRCA International Roofing Symposium 2011, Washington D. C., UnitedStates. http://www.nrca.net/rp/technical/symposium/default.aspx

General rightsCopyright and moral rights for the publications made accessible in the public portal are retained by the authors and/or other copyright ownersand it is a condition of accessing publications that users recognise and abide by the legal requirements associated with these rights.

? Users may download and print one copy of any publication from the public portal for the purpose of private study or research. ? You may not further distribute the material or use it for any profit-making activity or commercial gain ? You may freely distribute the URL identifying the publication in the public portal ?

Take down policyIf you believe that this document breaches copyright please contact us at [email protected] providing details, and we will remove access tothe work immediately and investigate your claim.

Downloaded from vbn.aau.dk on: September 03, 2020

Page 2: Aalborg Universitet Refurbishing roof systems and roof terraces … · 1 Refurbishing Roof Systems and Roof Terraces on a Major Residential Building Complex Tommy Bunch-Nielsen, Danish

Proceedings of the 2011 International Roofing Symposium

1

Refurbishing Roof Systems and Roof Terraces on a Major Residential Building Complex

Tommy Bunch-Nielsen, Danish Roofing Advisory Board Erik Brandt, Danish Building Research Institute

Denmark

Keyword

Roof terraces, green roof systems, up stand heights, plasticizer content, moisture.

Abstract

A major residential building complex with 1,725 apartments where two renovations of

the roof systems and terraces have taken place has been surveyed during a period

of more than 35 years. The building includes a large number of roof designs in the

form of roof terraces, vegetative roof systems and ballasted roof systems.

The roof design is of utmost importance for these buildings where the roof system is

not visible and extra care must be taken to ensure watertightness and service life.

This paper presents the experiences gained from the original roof systems and

short-lived second roofs, as well as precautions taken to ensure better results during

the latest refurbishment. One single faulty detail can spoil a project; therefore, it is

crucial that all critical details are analyzed thoroughly during the design and well

before launching any specification.

Authors

Tommy Bunch-Nielsen, M Sc. in civil engineering, is director of the Danish Roofing

Advisory Board and director of roof consulting firm BMT Building Enviroment

Consultants Ltd. E-mail [email protected]

Page 3: Aalborg Universitet Refurbishing roof systems and roof terraces … · 1 Refurbishing Roof Systems and Roof Terraces on a Major Residential Building Complex Tommy Bunch-Nielsen, Danish

Proceedings of the 2011 International Roofing Symposium

2

Erik Brandt, M. Sc. in civil engineering, is a senior researcher at the Danish Building

Research Institute. EMAIL [email protected]

Both authors have worked with roof system problems for more than 30 years.

Background

Farum Midtpunkt is a major residential building complex built from 1971-73. It has

1,725 apartments of different sizes. All apartments have one or two roof terraces.

All the terraces function as roofs in the apartments below, so the terraces’

watertightness is important.

The roof systems and terraces have been monitored during the full service life. They

have been renovated twice during the past 37 years.

The first renovation took place in 1990-91. After less than 20 years of service life,

major leaks were found in the roof systems and terraces, and after the first

renovation, major problems were experienced again less than 10 years later.

After the last renovation in 2001-04, the roof systems and terraces have been

monitored closely through yearly inspections. The number of detected leaks now is

low, and the service life is expected to be more than 30 years.

Page 4: Aalborg Universitet Refurbishing roof systems and roof terraces … · 1 Refurbishing Roof Systems and Roof Terraces on a Major Residential Building Complex Tommy Bunch-Nielsen, Danish

Proceedings of the 2011 International Roofing Symposium

3

Figure 1: View of terraced houses

The original roof systems and terraces

The original roof systems were a combination of vegetative roof systems and

ballasted roof systems as shown in Figure 2.

Figure 2: Original vegetative and ballasted roof systems

Page 5: Aalborg Universitet Refurbishing roof systems and roof terraces … · 1 Refurbishing Roof Systems and Roof Terraces on a Major Residential Building Complex Tommy Bunch-Nielsen, Danish

Proceedings of the 2011 International Roofing Symposium

4

The roof terraces were built up as shown in Figure 3.

Figure 3: Original roof terraces

The slope of the roof systems and terraces was close to zero, and there was

standing water on most roof systems and terraces, though it was hidden under

concrete tiles, ballast and vegetation.

The original roof membrane was about 8 mm thick and incorporated fiberglass mats.

The roof systems were leaking from day one. The contractor, who had a 10-year

warranty, consequently was forced to have two roofing workers fully employed for

most of the 10 years to repair the leaks.

The first general survey of the roof systems was carried out in 1981 and showed that

nearly 500 of the1,725 apartments had water penetration from the above roof or roof

terrace.

It was difficult to find the origin of the leaks because the membrane was hidden and

water could follow different layers and paths in the roof construction. So the leaks

never were directly above the water penetration or damaged area.

One of the surveys’ conclusions was that the flashings’ height was too low, so water

could run over the flashings on the roof terraces.

Page 6: Aalborg Universitet Refurbishing roof systems and roof terraces … · 1 Refurbishing Roof Systems and Roof Terraces on a Major Residential Building Complex Tommy Bunch-Nielsen, Danish

Proceedings of the 2011 International Roofing Symposium

5

The flashings themselves also were a problem as frost during the winter made the

water in the built-up roof system turn into a solid ice cake that expanded and caused

pressure on the roofing materials in the flashings, leading to severe cracks.

On the vegetative roof systems, the problem was roots penetrating the roofing

materials because they were not root-resistant.

After the end of the warranty period, the building owner repaired many of the roof

systems and terraces during a period of seven to eight years but finally gave up. The

increasing cost of repairs and tenants’ irritation reached a level that demanded a full

renovation.

The first roof renovation

The first renovation was carried out in 1990-91. The building owner decided to install

a thin insulation with a small slope and a new PVC single-ply membrane with a 15-

year warranty against leaks.

As previously mentioned, the original slope of the roofs was nearly zero, and to

improve the drainage, a slope of 1:100 for the membrane was established. This was

achieved by adding a tapered expanded polystyrene (EPS) insulation directly on the

original bitumen membrane as underlayment for the new loose-laid membrane.

Consequently, it changed the construction of the roof terraces as shown in Figure 4.

Page 7: Aalborg Universitet Refurbishing roof systems and roof terraces … · 1 Refurbishing Roof Systems and Roof Terraces on a Major Residential Building Complex Tommy Bunch-Nielsen, Danish

Proceedings of the 2011 International Roofing Symposium

6

Figure 4: Roof terraces after the first renovation

The vegetative roof systems and ballasted roof systems were changed as shown in

Figure 5.

Figure 5: Green roofs after the first renovation

No changes were made to the flashings’ height because it would involve changing

the windows, doors and wooden facades between the apartments and terraces.

Each terrace has two 6 m long façades facing the terrace, and the costs were

considered to be too high, even taking into account that it was possible to obtain a

15-year warranty.

Page 8: Aalborg Universitet Refurbishing roof systems and roof terraces … · 1 Refurbishing Roof Systems and Roof Terraces on a Major Residential Building Complex Tommy Bunch-Nielsen, Danish

Proceedings of the 2011 International Roofing Symposium

7

Figure 6: Example of flashings between terrace and apartment

The vegetative roof systems were present in two forms. The top of the buildings had

vegetative roof systems and ballasted roof systems with no critical flashings or up

stands. For some reason, a normal 1.2-mm PVC roof system with polyester

reinforcement was chosen and there was no special treatment to ensure resistance

to the environment under soil and gravel.

This proved to be a bad decision because a significant part of the PVC membrane’s

plasticizers seemed to disappear after a few years.

Page 9: Aalborg Universitet Refurbishing roof systems and roof terraces … · 1 Refurbishing Roof Systems and Roof Terraces on a Major Residential Building Complex Tommy Bunch-Nielsen, Danish

Proceedings of the 2011 International Roofing Symposium

8

Figure 7: The loss of plasticizers was critical because it caused the membrane to

shrink and become brittle.

The biological environment in the soil (bacteria and mold) on top of the membrane

probably was the reason for the loss of plasticizers; the plasticizer content fell from

35 percent to 5 percent in 10-12 years. The loss of plasticizer to the EPS insulation

was avoided by a separation layer of glass felt.

When the plasticizer content is below 20 percent, the product becomes brittle and

cracks readily will occur if people walk on the roofs. The loss of plasticizers also

causes the membrane to shrink, which leads to tension in the membrane and

creates problems with the flashings, which are pulled off the underlayment.

The rest of the vegetative roof systems were small roof systems situated on each of

the apartments, with flashings against the higher parts of the building. These roof

systems also were renovated with a PVC membrane but for some reason were

covered with an extra layer of PVC foil as a sacrificial layer. In the sacrificial layer,

the plasticizers have disappeared, but it has protected the real PVC roof system from

plasticizer loss. So these roof systems were not renovated in 2004. However, during

Page 10: Aalborg Universitet Refurbishing roof systems and roof terraces … · 1 Refurbishing Roof Systems and Roof Terraces on a Major Residential Building Complex Tommy Bunch-Nielsen, Danish

Proceedings of the 2011 International Roofing Symposium

9

the past few years, a number of problems with these roof systems have emerged,

and they now also are being renovated. The main problem is the flashings’

inadequate height and the fact that vegetative roof systems generally have increased

up to 50 percent in thickness during the past 20 years.

The second renovation

Roof terraces:

In 2000, after a number of investigations and surveys, [the building owner?] realized

the problems with the roof systems were not completely solved and a new

renovation was necessary.

There were two main problems. The first problem was the PVC roof membrane’s

poor performance partly because of using an incorrect product and partly because of

the membrane’s lack of protection from exposure to soil. The other main problems

with the terraces were the low height of the up stands. This problem was not solved

with the first renovation, where the main focus was to create a new watertight

membrane with a 15-year warranty.

Driving rain could lead to water penetration, and during the winter, the snow first

would thaw along the up stands while the rest of the roof system still would be

frozen. When the water had nowhere to go, it ran over the flashings at the up stands

and, in some cases, into the building.

Therefore, the roof terraces needed to be redesigned completely.

The most difficult part was increasing the height of the up stands. After much

consideration, it was decided all light facades would be replaced with new facades,

new doors and new windows that were 200 mm shorter, making it possible to create

new 200-mm higher up stands.

Page 11: Aalborg Universitet Refurbishing roof systems and roof terraces … · 1 Refurbishing Roof Systems and Roof Terraces on a Major Residential Building Complex Tommy Bunch-Nielsen, Danish

Proceedings of the 2011 International Roofing Symposium

10

Furthermore, it was deemed important to ensure water readily could get away from

the up stands and, therefore, the concrete pavers were placed on footings instead of

in gravel as before. The roof’s slope also was improved, and the design was

changed to a duo roof system (partly inverted roof system) to keep the membrane

frost-free during the winter. When using a partly inverted roof system design, the

slope can be reduced to 1:100 instead of the normal (in Denmark) 1:40.

Figure 8: New roof construction of terraces after the second renovation. The roof

membrane is protected between two layers of insulation, and water drainage is

facilitated by using rubber supports for concrete pavers instead of gravel.

The up stand design was improved by using concrete elements with external

insulation instead of wood parts .The flashings thereby were protected from

mechanical damage by extruded polystyrene (XPS) insulation with a mortar surface.

As an extra safety precaution, gutters were cut in the front of the terrace so water

could run out if the drainage system failed.

Page 12: Aalborg Universitet Refurbishing roof systems and roof terraces … · 1 Refurbishing Roof Systems and Roof Terraces on a Major Residential Building Complex Tommy Bunch-Nielsen, Danish

Proceedings of the 2011 International Roofing Symposium

11

Figure 9: The membrane is installed in a roof terrace after replacing the two facades

to create higher up stands.

Figure 10: The new 200-mm higher up stands. The up stands are protected from

mechanical damage by an external XPS insulation with a render facing.

Page 13: Aalborg Universitet Refurbishing roof systems and roof terraces … · 1 Refurbishing Roof Systems and Roof Terraces on a Major Residential Building Complex Tommy Bunch-Nielsen, Danish

Proceedings of the 2011 International Roofing Symposium

12

The vegetative roof systems and ballasted roof systems

The building owner wanted a 30-year warranty against leaks, and no contractor in

Denmark in 2001 was able to offer that for a vegetative roof system or ballasted roof

system. Consequently, it was decided to design and install the roof systems as

normal warm (compact) roof systems with visible roofing materials that included two

layers of SBS-polymer-modified bitumen mechanically fastened to the concrete

substrate. The first renovation with EPS and PVC roof systems was removed, but

the original roof covering underneath was kept in place. When the EPS was

removed, it was extremely wet and contained up to 5 kilograms of water per square

meter, which is more than the limit of 1 kilogram of water per square meter set by the

Danish Roofing Advisory Board.

The slope was increased to 1:40 (25 mm/1 meter) using a tapered insulation

corresponding to the standard for warm roof systems.

Figure 11: Warm roof system instead of vegetative or ballasted roof systems. The

original roof membrane is maintained, the insulation and slope are improved, and the

new roof membrane is fully visible.

Page 14: Aalborg Universitet Refurbishing roof systems and roof terraces … · 1 Refurbishing Roof Systems and Roof Terraces on a Major Residential Building Complex Tommy Bunch-Nielsen, Danish

Proceedings of the 2011 International Roofing Symposium

13

This changed the buildings’ architectural expression. Because only the green edge

of the roof systems was visible, the change was fully accepted by the residents

association and building owner after some consideration.

The distance between the outlets of the original roof systems were up to 20 meters

apart, and new outlets had to be installed to avoid insulation that was too thick. It

was not possible to install a new drainage system in the building, so drainage pipes

were installed in the insulation to connect the new outlets to the old drainage system.

A siphon system was used to make horizontal pipes possible.

This system often is used but is not considered to have the same safety as normal

systems with visible pipes. Therefore, the pipes were installed in a special canal of

polymer-modified bitumen roofing materials. The canal is equipped with moisture

sensors, allowing it to be checked for water from leaks in the pipes. There are more

than 350 moisture sensors installed, and each of them is checked once per year.

After the first seven years, it has proved to be working because only five small leaks

have been discovered.

Figure 12: Drainage pipe built into the

insulation in a special canal made from

the roof membrane

Page 15: Aalborg Universitet Refurbishing roof systems and roof terraces … · 1 Refurbishing Roof Systems and Roof Terraces on a Major Residential Building Complex Tommy Bunch-Nielsen, Danish

Proceedings of the 2011 International Roofing Symposium

14

Small vegetative roof systems

The small vegetative roof systems in the lower levels were not changed during the

second renovation because the membrane was not damaged at the time. However,

during the past few years, a number of problems have emerged, and the roof

systems gradually are being changed to new vegetative roof systems because they

have become an important part of the architecture.

To keep the vegetative part away from the flashings and gutters, a roof system with

a combination of three roof types was used as shown in Figure 13.

Figure 13: A vegetative roof system designed with sedum in the outer part and grass

in the inner part. The gutter is kept free of vegetation.

Page 16: Aalborg Universitet Refurbishing roof systems and roof terraces … · 1 Refurbishing Roof Systems and Roof Terraces on a Major Residential Building Complex Tommy Bunch-Nielsen, Danish

Proceedings of the 2011 International Roofing Symposium

15

Figure 14: Small vegetative roof systems are visible from the terraces in the

apartments above.

Conclusions

The past seven years of experiences with the new design of the roof systems and

terraces have shown it is possible to construct safe roof systems even on complex

buildings such as these. However, the design should include all gained knowledge

regarding roof systems and sustainable roof details and combine it with a detailed

maintenance plan that includes yearly surveys and necessary repairs.

The design incorporates a warranty of 30 years, allowing a maximum of five of the

1,725 apartments to have leaks per year. If more leaks occur, no maintenance fee is

paid for that year.

So far, only up to three leaks have occurred in one year, allowing the contractor his

fee every year.

Page 17: Aalborg Universitet Refurbishing roof systems and roof terraces … · 1 Refurbishing Roof Systems and Roof Terraces on a Major Residential Building Complex Tommy Bunch-Nielsen, Danish

Proceedings of the 2011 International Roofing Symposium

16

Figure 15: A cozy roof terrace without leaks

The lessons learned are that a warranty cannot solve major problems, such as up

stands that are too low, etc. It is vital for the designer to have a solid background

regarding roof systems and roofing details, enabling him to make the right decisions

before beginning a complicated and large-scale renovation. It especially is important

to identify all critical details and find sustainable and buildable solutions with long

service lives.