A1...Volume of sandy loam required to fill Strata Cell and Root Director spaces (including root ball...
Transcript of A1...Volume of sandy loam required to fill Strata Cell and Root Director spaces (including root ball...
![Page 1: A1...Volume of sandy loam required to fill Strata Cell and Root Director spaces (including root ball volume) = approximately 16.2 Cu. m. Additional allowance needs to be made for settlement](https://reader034.fdocuments.us/reader034/viewer/2022051904/5ff50a9cdbb06c0a14685ff8/html5/thumbnails/1.jpg)
![Page 2: A1...Volume of sandy loam required to fill Strata Cell and Root Director spaces (including root ball volume) = approximately 16.2 Cu. m. Additional allowance needs to be made for settlement](https://reader034.fdocuments.us/reader034/viewer/2022051904/5ff50a9cdbb06c0a14685ff8/html5/thumbnails/2.jpg)
PLAN VIEW WITH CANOPY HIDDEN1:33.33
SASLP Arborguy strapped anchorsystem c/w ground anchors
Footpath/road construction
SIDE VIEW1:33.33
ISOMETRIC VIEW WITH CUT-AWAY TO SHOW PRODUCTS1:33.33
A A
PARTIAL SECTION A-A
GLTWGNA twinwall geonetlaid over StrataCells
Drainage to engineers detail
Galvanised tree grille supportframe set on concrete haunch
RD1400A Root Director, large,modular root barrier system
GLSCMA StrataCell structure - 3 modulesdeep x 9 modules square (3 x 3 x 3
void below Root Director) loadedwith topsoil - sandy loam to BS3882
ULLS186A Ullswatervertical steel tree guard
1.8m high x 600mmdiameter secured to grille
Package includes:
RRPREC1C RootRain Precinct single inlet aeration/irrigationsystem with cast inlet
RRARBVDI3C Arborvent double inlet aeration/irrigation systemwith cast inlets
GLSCMA StrataCells, 216 No. 500mm x 500mm x 250mm
GLTWGNA twinwall geonet - 27 Sq. m
ADUR15A Adur 1500mm x 1500mm tree grille, finished in black, with galvanised steel support frame
ULLS186A Ullswater vertical steel tree guard, with rolledangle-section rings, 16mm round vertical bars topped with50mm diameter ball finials, finished in black
RD1400A Root Director
GLGTTA Tree guard tie
SASLP Arborguy strapped anchor system - Large Note: Special drive rod required for SASLP installation Volume of sandy loam required to fill Strata Cell and Root Director spaces (including root ball volume) = approximately 16.2 Cu. m. Additional allowance needs to be made for settlement
RRPREC1C RootRainPrecinct irrigation system
RRARBVDI3C Arborvent doubleinlet aeration/irrigation system
3000Aprx.
1330A
prx.
560
Aprx.
GLGTTA Tree guard tieattached to the top ring
of the tree guard
ADUR15A1500mm x 1500mm
tree grille c/wRootRain Precicnt
irrigation inlet
4500Aprx.
DRAWNCHECKEDENG APPRMGR APPR
UNLESS OTHERWISE SPECIFIEDDIMENSIONS ARE IN MILLIMETERS
ANGLES ±X.X°2 PL ±X.XX 3 PL ±X.XXX
NAMEAdrian White
DATE21/02/2011
TITLE
GR1022 Tree pit system installationSIZE
A1DWG NO
GRE-101113-DFT-001REVC
GR1022.dftSCALE: WEIGHT: SHEET 1 OF 1
REVISION HISTORYREV DESCRIPTION DATE APPROVED
TREE PRODUCT PACKAGES
FILENAME:
Greenleaf Urban tree and landscape products3 Hayward Way, Ivyhouse Industrial Estate, Hastings, East Sussex TN35 4PL
Tel: +44 (0)1424 717 797 Fax: +44 (0)1424 205 240E-mail: [email protected] Website: www.treesintowns.com