A TTENION VENDOR I T F 1ST RE-INSPECTION S...

6
INSPECTION REPORT CLIENT Example Company REPORT NUMBER XXX00007813C FAX NUMBER PAGE 1 OF 2 ATTENTION Pre / Insp./ Rev INSPECTION DATE VENDOR TITLE Quality Manager MANUFACTURER CC TO INSPECTION LOCATION TITLE FAX NUMBER THIS DOCUMENT SERVES AS EVIDENCE THAT PRO QC INTERNATIONAL LIMITED HAS PERFORMED THE INSPECTION SERVICES DETAILED HEREIN. TYPE OF SERVICE FINAL PRE-SHIPMENT INSPECTION 1ST RE-INSPECTION 2ND RE-INSPECTION x Surface Treatment and Assembly Process REFERENCE PAGE 2 PAGE PAGE PAGE PRODUCT DESCRIPTION ACOUSTIC PANELS JOB COLOR / FINISH BRAND - P.O. NUMBER 123456 P.O QTY 136 INSP. LOT QTY UNIT OF MEASURE Set SHORT SHIP QTY 0 INSPECTION RESULT Passed REF PAGE NOTE NUMBER REASON FOR ON-HOLD INSPECTION RESULT APPLICABLE REMARKS 1. Panel’s are stored on wooden pallets inside the storage area. See photos. 2. During inspections, we did not find any non-conformances. 3. All 136 panels are finished with the assembly process and protected using a plastic laminate sheet. 4. All 136 panels are ready for the loading process. THE RESULTS DETAILED AND DETERMINATION JUDGED IN THIS DOCUMENT REFLECTS THE FINDINGS OF PRO QC INTERNATIONAL AT THE TIME AND PLACE OF INSPECTION ONLY. EVIDENCE OF ACTUAL SHIPMENT IS NEITHER OFFERED NOR IMPLIED. THIS REPORT DOES NOT RELEASE THE VENDOR OR MANUFACTURER FROM ANY OBLIGATIONS, CONTRACTUAL OR OTHERWISE, IN EFFECT WITH THE CLIENT TO REPAIR, REPLACE, OR COMPENSATE FOR ANY PRODUCT OR PART THEREOF IN WHICH DEFECTIVE CONDITIONS MIGHT HEREAFTER BE FOUND OR SUBSEQUENTLY DEVELOP. PRO QC INTERNATIONAL ASSUMES NO RESPONSIBILITY, AND SHALL IN NO WAY BE HELD LIABLE, FOR ANY DEFECTIVE CONDITIONS BEYOND THOSE CLEARLY DETECTABLE WITHIN THE LIMITS OF THE SPECIFIC INSPECTION SERVICES ORDERED BY THE CLIENT. RESPECTFULLY SUBMITTED BY: PRO QC INTERNATIONAL LIMITED PRO QC INTERNATIONAL LIMITED, COPYRIGHT © DOCUMENT 07/97

Transcript of A TTENION VENDOR I T F 1ST RE-INSPECTION S...

!

INSPECTION REPORT

CLIENT

Example Company REPORT NUMBER

XXX00007813C FAX NUMBER

PAGE

1 OF 2 ATTENTION

Pre / Insp./ Rev

INSPECTION DATE

VENDOR

TITLE

Quality Manager MANUFACTURER

CC TO

INSPECTION LOCATION

TITLE

FAX NUMBER

THIS DOCUMENT SERVES AS EVIDENCE THAT PRO QC INTERNATIONAL LIMITED HAS PERFORMED THE INSPECTION SERVICES DETAILED HEREIN.

TYPE OF SERVICE

FINAL PRE-SHIPMENT INSPECTION

1ST RE-INSPECTION 2ND RE-INSPECTION

x

Surface Treatment and Assembly Process

REFERENCE

PAGE 2

PAGE

PAGE

PAGE PRODUCT

DESCRIPTION

ACOUSTIC PANELS

JOB

COLOR / FINISH

BRAND

-

P.O. NUMBER

123456

P.O QTY

136

INSP. LOT QTY

UNIT OF MEASURE

Set

SHORT SHIP QTY

0

INSPECTION RESULT

Passed

REF

PAGE

NOTE NUMBER

REASON FOR ON-HOLD INSPECTION RESULT

APPLICABLE REMARKS

1. Panel’s are stored on wooden pallets inside the storage area. See photos. 2. During inspections, we did not find any non-conformances. 3. All 136 panels are finished with the assembly process and protected using a plastic laminate sheet. 4. All 136 panels are ready for the loading process.

THE RESULTS DETAILED AND DETERMINATION JUDGED IN THIS DOCUMENT REFLECTS THE FINDINGS OF PRO QC INTERNATIONAL AT THE TIME AND PLACE OF INSPECTION ONLY. EVIDENCE OF ACTUAL SHIPMENT IS NEITHER OFFERED NOR IMPLIED. THIS REPORT DOES NOT RELEASE THE VENDOR OR MANUFACTURER FROM ANY OBLIGATIONS, CONTRACTUAL OR OTHERWISE, IN EFFECT WITH THE CLIENT TO REPAIR, REPLACE, OR COMPENSATE FOR ANY PRODUCT OR PART THEREOF IN WHICH DEFECTIVE CONDITIONS MIGHT HEREAFTER BE FOUND OR SUBSEQUENTLY DEVELOP. PRO QC INTERNATIONAL ASSUMES NO RESPONSIBILITY, AND SHALL IN NO WAY BE HELD LIABLE, FOR ANY DEFECTIVE CONDITIONS BEYOND THOSE CLEARLY DETECTABLE WITHIN THE LIMITS OF THE SPECIFIC INSPECTION SERVICES ORDERED BY THE CLIENT.

RESPECTFULLY SUBMITTED BY:

PRO QC INTERNATIONAL LIMITED

PRO QC INTERNATIONAL LIMITED, COPYRIGHT © DOCUMENT 07/97

!

See attached photos of process.

Panel Part Number

Panel quantity

Final Size

Type

Surface Treatment and Assembly process.

Thick

Height

Width

Width 2

Visual & Color check (RAL 7038 Agate Grey)

Thermal rock install

Perforated sheet install

Powder coating thickness 65~90 micron

1 28

50

3000

1000

-

Female + Male

Passed

Passed

Passed

Passed 2 2

50

3000

1000

-

Female + Male

Passed

Passed

Passed

Passed 3 2

50

3000

1000

-

Female + Male

Passed

Passed

Passed

Passed 4 4

50

3000

975

-

Male + Male

Passed

Passed

Passed

Passed 5 2

50

3047

589

441

Sloped Top

Passed

Passed

Passed

Passed 6 2

50

3047

590

441

Sloped Top

Passed

Passed

Passed

Passed 7 2

50

3047

480

291

Sloped Top

Passed

Passed

Passed

Passed 8 2

50

3047

480

290

Sloped Top

Passed

Passed

Passed

Passed 9 4

50

3000

635

-

Female + Male

Passed

Passed

Passed

Passed 0 4

50

3000

550

-

Female + Male

Passed

Passed

Passed

Passed 11 8

50

707

1000

-

Female + Male

Passed

Passed

Passed

Passed 12 2

50

585

1057

-

Male + Male

Passed

Passed

Passed

Passed 13 2

50

585

1057

-

Female + Male

Passed

Passed

Passed

Passed 14 4

50

1630

406

-

Female + Male

Passed

Passed

Passed

Passed 15 36

50

1630

1000

-

Female + Male

Passed

Passed

Passed

Passed 16 2

50

1630

1000

-

Female + Male

Passed

Passed

Passed

Passed 17 2

50

1630

1000

-

Female + Male

Passed

Passed

Passed

Passed 18 2

50

1630

1000

-

Female + Male

Passed

Passed

Passed

Passed 19 2

50

1630

1000

-

Female + Male

Passed

Passed

Passed

Passed 20 2

50

1440

635

-

Female + Male

Passed

Passed

Passed

Passed 21 2

50

1440

635

-

Female + Male

Passed

Passed

Passed

Passed 22 2

50

1630

1000

-

Female + Male

Passed

Passed

Passed

Passed 23 2

50

1630

1000

-

Female + Male

Passed

Passed

Passed

Passed 24 4

50

1630

560

-

Female + Male

Passed

Passed

Passed

Passed 25 4

50

1630

466

-

Female + Female

Passed

Passed

Passed

Passed 26 2

50

387

1355

-

Female + Male

Passed

Passed

Passed

Passed 27 2

50

387

1356

-

Male + Male

Passed

Passed

Passed

Passed 28 2

50

3000

1000

-

Female + Male

Passed

Passed

Passed

Passed 29 2

50

3000

1000

-

Female + Male

Passed

Passed

Passed

Passed

!

Application of heavy duty silicon between stiffeners and outer skin. Silicon condition after application.

Inserting acoustic infill, Thermalrock S60 (Density 60 kg/m3). Completion of insert in the acoustic infill.

Covering the infill with plastic sheeting. Plastic sheet will protect the infill from coming out.

Assembling the perforated sheet to the panel. Perorated sheet after assembly.

Drilling holes at the stiffeners to insert rebate. Accept left and right Rebate the hole to make sure perforated sheet attaches to stiffeners. stiffeners.

Using Henrob to attach between perforated sheet and stiffeners for Henrob are stronger then rebate. left and right panel.

Conducting visual inspection of the panel. Re-laminaing the panel after the inspection is done.

Panel is ready to insert acoustics infill. Finished panel.

Cover the infill using plastic sheet. Assemble the perforated sheet to the panel.

Completely remove plastics cover to check panel color. Panel colors match with sample color sheet.

Check coating thickness using Elcometer. DFT thickness range are from 65 ~ 90 micron.

Powder coating thickness, 86.9 micron. Powder coating thickness, 98.1 micron.