A presentation for

15
A presentation for June 24, 2002 June 24, 2002 Energy Star Ceiling Fan Energy Star Ceiling Fan Industry Meeting Industry Meeting World Trade Center, Dallas, Texas

description

A presentation for. Energy Star Ceiling Fan Industry Meeting. World Trade Center, Dallas, Texas. June 24, 2002. ITS Global Network. Largest product and commodities testing organization in the world More than 2 million annual inspections, certifications, and tests performed worldwide - PowerPoint PPT Presentation

Transcript of A presentation for

Page 1: A presentation for

A presentation forA presentation for

June 24, 2002June 24, 2002

Energy Star Ceiling Fan Industry MeetingEnergy Star Ceiling Fan Industry MeetingWorld Trade Center, Dallas, Texas

Page 2: A presentation for

ITS Global NetworkITS Global Network

Largest product and commodities testing organization

in the world

More than 2 million annual inspections, certifications,

and tests performed worldwide

254 laboratories around the world

504 offices in 99 countries

More than 10,400 employees worldwide

Publicly offered on the London Stock Exchange

Page 3: A presentation for

Over 100 Years of HistoryOver 100 Years of History

Founded by Thomas Edison in 1896 to

verify light bulbs his company was

manufacturing

Expanded into performance testing of a

broad spectrum of manufactured goods

First product certification program was

developed with Certified Ballast

Manufacturers (CBM) in 1941

Page 4: A presentation for

NRTL Accreditation - What It IsNRTL Accreditation - What It Is

NRTL accreditation is the benchmark for excellence for product safety certification laboratories in the United States.

Laboratories are accredited by the U.S. Occupational Safety and Health Administration for 5 years, and then audited by OSHA for continued accreditation.

An NRTL must be qualified both to test products and to certify products.

Certification includes periodic factory audits to assure that manufacturers continue to produce products in accordance with the factory audit manual.

Page 5: A presentation for

Services Available at ITS Cortland Include:Time to Market - One Stop Shopping - All Services in One Location

Services Available at ITS Cortland Include:Time to Market - One Stop Shopping - All Services in One LocationNoise - our Acoustical department offers a

fully qualified 470 cu. meter reverberation

room and hemi anechoic chamber

Airflow - per Energy Star specification,

AMCA, HVI

Electrical Safety - testing conducted in

accordance with UL 507

R & D - failure analysis, life cycle, product

comparison, durability

Page 6: A presentation for

Energy Star Testing of Lighting ProductsEnergy Star Testing of Lighting ProductsNVLAP Accredited Photometric

Testing Laboratory

Regularly perform all lamp and

ballast tests as required by Energy

Star, including fixtures, traffic signals,

& Compact Fluorescent Lamps (CFL)

For Energy Star Testing of Lighting

Products:

All lamp and ballast combinations

must be tested

Typical turnaround 3-4 weeks

Contact Todd Straka, Sr. Account Manager, for Contact Todd Straka, Sr. Account Manager, for pricing: 607-758-6280 or [email protected]: 607-758-6280 or [email protected]

Life Testing at our Cortland, NY FacilityLife Testing at our Cortland, NY Facility

Page 7: A presentation for

160,000 square-foot facility on 45 acres in Upstate New York250 engineers, technicians, managers, and administrative staffFacility runs 24 hours/day, 7 days/weekSeveral one-of-a-kind test facilitiesTest facility design and construction specialists

Cortland, NY Facility

Page 8: A presentation for

Cortland Ceiling Fan Test Cortland Ceiling Fan Test FacilityFacility

Page 9: A presentation for
Page 10: A presentation for

CFM Airflow - Overall

0

2000

4000

6000

8000

10000

12000

Overall Test Results

CFM

Min. High

5% High

High

Min. Med.

5% Med.

Medium

Min. Low

5% Low

Low

Page 11: A presentation for

CFM/Watt Airflow Efficiency - Overall

0

50

100

150

200

250

Overall Test Results

CFM

/Wat

t

Min High

5% High

High

Min Medium

5% Medium

Medium

Min Low

5% Low

Low

Page 12: A presentation for

CFM Airflow - 52" Fans Only

0

1000

2000

3000

4000

5000

6000

7000

8000

9000

10000

Overall Test Results

CFM

Min. High

5% High

High

Min. Med.

5% Med.

Medium

Min. Low

5% Low

Low

Page 13: A presentation for

CFM/Watt Airflow Efficiency - 52" Fans Only

0

50

100

150

200

250

Overall Test Results

CFM

/Wat

t

Min High

5% High

High

Min Medium

5% Medium

Medium

Min Low

5% Low

Low

Page 14: A presentation for

Ensuring Prompt and Accurate Testing and Reporting Ensuring Prompt and Accurate Testing and Reporting Submit new products complete with correct model number and manual

Use shipping label that was provided or reference quote number on box

Runtime: all samples should be new, unused product. Additional runtime, other than what is already established can effect results

Failed units, must submit new sample for re-test light kits must be attached

Page 15: A presentation for

Thank you!Thank you!