A Plan of compact neutron source for industr

23
A Plan of compact neutron source for industrial application at RIKEN Advanced Manufacturing Metrology Laboratory, RIKEN Yutaka YAMAGATA UCANS II Indiana University 2011 July 1

Transcript of A Plan of compact neutron source for industr

Page 1: A Plan of compact neutron source for industr

A Plan of compact neutron sourcefor industrial application at RIKEN

Advanced Manufacturing MetrologyLaboratory, RIKEN

Yutaka YAMAGATA

UCANS II Indiana University 2011 July 1

Page 2: A Plan of compact neutron source for industr

Overview• We are planning to construct a compact

neutron source based on proton linac for thepurpose of industrial and academic use.

• Outline

– Current status at RIKEN

– Neutron Imaging for industrial applications

– Neutron scattering instrument for industrial andacademic

UCANS II Indiana University 2011 July 2

Page 3: A Plan of compact neutron source for industr

Current status at RIKEN• The former VCAD System Research program has come to an end

and a new team dedicated for neutron imaging was formed.

• The aim of the new team “Advanced Manufacturing MetrologyLaboratory” is aiming for:

– Neutron Imaging for industrial applications

• Radiography of industrial components at relatively weak neutron beam ports

• Development of new imaging technique (Phase contract imaging)

• Development of detectors and instrumentation devices

– Preparation for the construction of accelerator based compactneutron source

• Neutronic design of target/moderator station

• Thermal/mechanical design of target

• Construction of simple target/moderator station using small proton linac

– Obtain necessary funding !

UCANS II Indiana University 2011 July 3

Page 4: A Plan of compact neutron source for industr

Demands for non-destructive testing in industries

• Recent problems in production technology in Japan

– Lower cost, energy efficient, recycled material, high quality, product liability

– Slim, lean but sufficient design for optimum cost/performance

• Utilization of computer simulation in the design process is keen

– Optimize hydrodynamic form

– Minimize car body weight

– Simple and sufficient design of engines, motors and batteries

• Computer simulation (Structural, CFD/thermal, molding...) are not alwaysaccurate without metrological data

– Methodology to "measure" real physical phenomena become important

– Fluid visualization, stress measurement, temperature, magnetic/electric field,chemical reaction and so on

• Significance of Non-destructive testing goes up– Product liability, quality control

UCANS II Indiana University 2011 July 4

Page 5: A Plan of compact neutron source for industr

VCAD System Research Program• VCAD System (Volume CAD) can realize computer model based on "real"

object - VCAD model

• Based on VCAD model, various computational simulations can be carriedout (CFD, Structural, molding, optical ...)

• These simulations are far realistic than those based on CAD models

External simulation softwares

IGES

STL

VCAD ModellingGeneralized VCAD model

S-CAD

X-Ray CT, MRI,Slicer, NeutronRadiography

Discrete "Geometory" model

Subdivision surfaces

The Nagata patch

Implicit Surfaces

V-Slim

Triangles with normalsV-ObjCreator

Noise RemovalV-Smoother V-Cat

Structural Analysis(X-FEM)

Structural Analysis(FEM)

Optics Ray-tracing

Fluid Thermal Simulation

V-X3D

V-Struct

V-Shrink

V-MultiMat

V-Sphere

V-Opt

V-Flow2D、3D

CAM

Design

3D Metrology + internalstrucutre

Analytical form

Point Cluds

BMPTIFF

VOXELExternal Mesh Generator

V-Biomech

V-Cam2

V-Polish

Bone Remodelling

V-BoneRemodeling

Octree Voxel

V-Xgen

Tetrahedral Elements

Vxxx2tets

VCAD Framework

Degenerated HexahedralElementsVxxx2hex

V-Subdivision3D

VCAD Modeller

Discrete model of "Object" and"Fluidics" controlled by cell

V-Sphere Software in public release

Metrology

Handling of Volume Data

UCANS II Indiana University 2011 Julytype "VCAD" at Google to see VCAD Website http://vcad-hpsv.riken.jp/en/

5

Page 6: A Plan of compact neutron source for industr

Structural AnalysisFluid Dynamics

Bio-Medical Application ©RIKEN, 2009

Data: Courtesy of Nissan Motor

Meshing & Grid Generation

Design & Modeling

VCAD: Integrated CAD/CAM/CAE/CAT forMulti-Material Volumetric Objects

Page 7: A Plan of compact neutron source for industr

X-ray CT fo industrial and medical

3D internal structuremicroscopy (Slicer)

Confocal laser microscopy

Neutron Radiography(JRR-3)

Metrology of volume 3D data of real "objects"

INPUT to VCAD

Surfacemetrology

CAD Design data

volume 3D data

UCANS II Indiana University 2011 July

3D Volume data input method to VCAD System

7

Page 8: A Plan of compact neutron source for industr

Example of imaging and simulation for the industry using X-ray

1. Measure “Real” component2. Construct 3D volume model inside

computer3. Computational simulation to obtain

necessary information (structuralstrength, heat removal, etc)

MetrologyMetrology

ModellingModelling

SimulationSimulation

UCANS II Indiana University 2011 July 8

Page 9: A Plan of compact neutron source for industr

What the industry needs from neutron imaging

• There are a number of components that cannot bemeasured by X-ray with sufficient information. (Steelcomponents, metal/plastic composite, bondingmaterial, plastic parts, CFRP etc..)

• It is very important for industries to produceinterpreted result rather than just an radiographyimage!

• It is also important that neutron imaging facility canbe easily accessed. Beam time of several times peryear is not convenient enough for industrial use.

Easy to access, convenient neutron imaging by compact neutronsource is important

UCANS II Indiana University 2011 July 9

Page 10: A Plan of compact neutron source for industr

Neutron imaging for the industries

UCANS II Indiana University 2011 July 10

Page 11: A Plan of compact neutron source for industr

Neutron imaging for industries

• Automobile industries

– Batteries (liquid motion, safety tests)

– Structural components (residual stress)

– Plastic/metal composite components(cables, tires)

• Aerospace industries

– CFRPs(carbon fiber reinforced plastics)

– Turbine blades (mold removal)

– Metal bonded components (bondingmaterial distribution)

– Metal-plastic composite components

UCANS II Indiana University 2011 July 11

Page 12: A Plan of compact neutron source for industr

Neutron radiography at relatively low intensity source

• Neutron radiography is conducted atKUR E-2 port to verify the possibility ofimaging at relatively low neutron flux.

Kyoto University Research Reactor (KUR)

850

729.6

253

Imaging camera with 6LiF+ZnS(Ag)scintillatorCooled CCD Camera 11 Millionpixel(4008x2764)Resolution ~50μmImaging area: 150mmx150mm

Specification of E-2 portNeutron flux: 8x104 n/cm2/sec @1MW

4x105 n/cm2/sec@1MWL/D= 100Beam diameter = φ15cm

UCANS II Indiana University 2011 July 12

Page 13: A Plan of compact neutron source for industr

Some examples of imaging at KURBath toy(plastic-metalcompositesample)1min at 1MW

Concretesamplew/steelreinforcement20min@1MW

Steelpyramid(5cm)1min@1MW

Plastic Lens20sec @5MW

Nb sample withmicro defects1min @ 5MW

Practical images can be captured by 1 minexposure in most cases at 1MW

UCANS II Indiana University 2011 July 13

Page 14: A Plan of compact neutron source for industr

CT reconstruction and movie

• CT reconstruction is also possible with severalhours of imaging

Volume rendered image ofbath toyCT capture 60sec x 500images1002x668 10 hoursResolution 160um

Volume renderedimage of connectorCT capture a B-4 port

Simple movie (512x512)By EMCCD 8fps at E-2 5MW

By using latest CCD camera with very high sensitivity,a small movie can be captured.

Possibility of relatively low neutron flux for practical radiographyUCANS II Indiana University 2011 July 14

Page 15: A Plan of compact neutron source for industr

Neutron interferometry imaging(Phase contract)

• Neutron radiography(absorption) gives better contrast over X-ray to plasticand CFRP(Carbon fiber reinforced plastics)

• Interferometry imaging gives even better recognition of organic materials,which may be possible to distinguish water, PMMA, epoxy and CFRP.

• This imaging technology is crucial to components where light-weight isvery important.

Talbot-Lau Interferometer using threediffraction gratings

Epoxy resin in water(Simulation)

Absorption based image

Phase contract image

Combined with compactneutron source, there is apossibility of non-destructive testing ofaircraft components

15Interference image at JRR3 ULS UCANS II Indiana University 2011 July

Page 16: A Plan of compact neutron source for industr

Design and research toward compactneutron source

• Simulation and design of target-moderatorstation by PHITS code [poster: S.Wang]

• Thermal and Mechanical design oftarget[poster: J.Ju]

• Imaging detector development[poster:K.Hirota]

UCANS II Indiana University 2011 July 16

Page 17: A Plan of compact neutron source for industr

Simulation and design of target-moderator station by PHITS code

Concrete

Graphite

Aluminum

Beryllium metal

Moderator

Lead

SS304z

y

Detector

Do

utDin

Concrete

9Be (p, n) 9B

Protonbeam

B

For the small proton linac (3.5MeV, 100uA) at Faculty of Science at Kyoto University,we are designing target/moderator/shielding for thermal neutron radiography

2.0E+04

2.5E+04

3.0E+04

3.5E+04

4.0E+04

4.5E+04

5.0E+04

5.5E+04

6.0E+04

6.5E+04

2 4 6 8 10 12 14

Moderator thickness (cm)

Polyethylene

Light Water

Mesitylene

µSv

/10

A/h

10-2

10-1100101

102

105106

10-3

107

103

104

108µ

Sv/1

00

µA

/h

10-4

10-3

10-2

10-1

100

101

1µSv/100µA/h

Design of “simple” target moderator

Shielding calculation for neutron & photon

Moderator optimization

1.00E+04

1.00E+05

1.00E+06

1.00E+07

1 11 21 31 41

L/Din

Thermal neutron flux at 2 m

Thermal neutron flux at 5 m

Thermal neutron flux vs L/D

4.4E+3 n/cm2/100uA (5m L/D=50)

UCANS II Indiana University 2011 July 17

Page 18: A Plan of compact neutron source for industr

Thermal and Mechanical design of target• Heat removal and structural strength is the most important factor for stable operation of

compact neutron source. Thermal propoerties are simulated using FEM code by fluid-thermal combined analysis. Hydrogen damage caused by proton beam is considered interms of hydrogen diffusion in metals and hydrogen embrittlement effect to avoid blistering.

Be Target WaterNb

Proton Beam

7MeV, 10 kW (1.4 mA)2MeV Beam Stop

H ion

Thermalenergy

?

?

?

Basic design concept Hydrogen distribution by SLIM

Mechanical strength consideration

Be368 um

Nb

3 mm

Depth

H ion generationNo flux

0 concentration

Symmetry Symmetry

Hydrogen diffuse model analysis

Heat removal by water cooling

UCANS II Indiana University 2011 July 18

Page 19: A Plan of compact neutron source for industr

Neutron detectors and optics developmentat RIKEN

• Neutron optics

Ellipsoidal neutron mirrorUltra High Precision machined mirror

with multilayer coating (used in mf-SANS)

Neutron DetectorsRPMTRegister netoworkPhotoMutiplying Tubetype detector. 2D Positionsensitive and countingmode. Capble of doingpulse neutronspectrometry.

Pixel type detectorHigh speed pixel detectorcapable of counting mode.Used in pulse neutronimaging.

Neutron diffractiongratings

Neutron Lens

10mm

19

Imaging camera withCCD + Scintillator6LiF+ZnS scintillatorand cooled,intensified CCD

UCANS II Indiana University 2011 July

Page 20: A Plan of compact neutron source for industr

Scattering experiments using compact neutron source• Unlike high-intensity spallation neutron source facilities, flux of compact

neutron source is limited. So, effective method of scattering experiment islimited.

mf-SANS may be an effectiveway for scattering experimentat CNS

mf-SANS utilizes neutron optics toeffectively increase the resolution withvery small instrument size (~ 2m)

mf-SANS at JRR-3

Detector

Ellipsoidalmirror

Sample

aperture

monochrometer

Incident beam

Ellipsoidal mirror (0.9m) for mf-SANS

• mf-SANS may be able to obtain useful datawith relatively low neutron flux

• small angle and middle angle scatteringmay be possible with same instrument

UCANS II Indiana University 2011 July 20

Page 21: A Plan of compact neutron source for industr

Expected plan of the facility• Facility space of 10mx20m• 7 to 10 MeV proton linac (start with current 100uA and upgrade to 3mA)• Thermal and cold TMR• Thermal beamline for neutron radipgraphy• Cold beamline for mf-SANS and pulse imaging

UCANS II Indiana University 2011 July 21

Page 22: A Plan of compact neutron source for industr

Conclusion

• A plan for compact neutron source at RIKEN isin progress.

• Compact neutron source will be veryimportant for industry users and may expandthe users of neutrons.

• Design and plan of RIKEN-CNS is under waybased on proton linac.

UCANS II Indiana University 2011 July 22

Page 23: A Plan of compact neutron source for industr

Acknowledgements• VCAD System Research Program data and figures : Dr. A. Makinouchi, Dr.

H.Sunaga, Mr. S.Mihara, Dr.H.Yokota, Dr. T.Sera

• Neutron imaging at KUR in collaboration with: Prof. Y.Kawabata, Dr. S.Hino,Dr.S.Sugiyama, and Dr.M.Kitaguchi

• Target moderator simulation and design in collaboration with HokkaidoUniversity: Prof. Y.Kiyanagi, Prof. S.Kamiyama, Dr. Hiraga, and KEKDr.Mishima, Dr.H.M.Shimizu

• Plan for mf-SANS in collaboration with: Prof. M.Furusaka, Dr.Onuma(NIMS)

• Development of TMR for compact proton linac is in collaboration withFaculty of Science, University of Kyoto: Prof. Nagae, Prof.Iwashita

• Advanced Manufacturing Metrology Laboraotry members: Dr.Y.Otake,Dr.K.Hirota, Dr. S.Wang, Dr.M.Takamura, Dr. J.Ju, Mr.S.Morita

UCANS II Indiana University 2011 July 23