A New Measurement of from KTeV

37
July 2001 Snowmass A New Measurement of from KTeV Introduction The KTeV Detector Analysis of 1997 Data Update of Previous Result Conclusions E. Blucher, Chicago e KTeV Collaboration: Arizona, Chicago, Colorado, Elmhurst, Fermilab, Osaka, Rice, Rutgers, UCLA, UCSD, Virginia, Wisconsin

description

A New Measurement of  from KTeV. E. Blucher, Chicago. Introduction The KTeV Detector  Analysis of 1997 Data Update of Previous Result Conclusions. The KTeV Collaboration: Arizona, Chicago, Colorado, Elmhurst, Fermilab, Osaka, Rice, Rutgers, UCLA, - PowerPoint PPT Presentation

Transcript of A New Measurement of from KTeV

Page 1: A New Measurement of   from KTeV

July 2001 Snowmass

A New Measurement of from KTeV

• Introduction• The KTeV Detector Analysis of 1997 Data• Update of Previous Result• Conclusions

E. Blucher, Chicago

The KTeV Collaboration: Arizona, Chicago, Colorado, Elmhurst, Fermilab, Osaka, Rice, Rutgers, UCLA, UCSD, Virginia, Wisconsin

Page 2: A New Measurement of   from KTeV

1

/

/61

/Re0000

sL

sL

KK

KK

/ 0 direct CP violation

KL~ Kodd + Keven

“Direct”in decayprocess

“Indirect” from asymmetric mixing

Indirect vs. Direct CP Violation

00K K

Standard Model Prediction: Re() ~ (0-30)10-4

Page 3: A New Measurement of   from KTeV

KTeV Detector

KL + KS

KL

For EK ~ 70 GeV, KS: c ~ 3.5mKL: c ~ 2.2 km

E832: E799: rare decays

Page 4: A New Measurement of   from KTeV

Calorimeter Performance

Page 5: A New Measurement of   from KTeV

KTeV Datataking

• First result (PRL 83, 22 (99)) used from 1996 and from first 18 days of 1997 E832 run (1997a).• Current analysis is based on remaining 1997 data -- ~3 larger sample than first result.• 1999 run 1996 + 1997 with better systematics

Page 6: A New Measurement of   from KTeV

KS +

Page 7: A New Measurement of   from KTeV

rab

zab

a

b

0

22

2a b ab

ab

E E rz

m

KL

Page 8: A New Measurement of   from KTeV

1997 Reconstructed Mass Distributions(before background subtraction)

~1.6 MeV

~1.5 MeV

Vacuum beam (KL) Reg. Beam ("KS") 00 + 00 )stat

(106) (106) (106) (106) (10-4)1996 2.6 0.9 4.5 1.4 3.01997 8.6 2.5 14.9 4.1 1.796+97 11.2 3.4 19.4 5.6 1.5

Page 9: A New Measurement of   from KTeV

Backgrounds

• Misidentified kaon decays– For K+-: KLe, KL

– For K00: KL000

• Scattered K events– From regenerator and final collimator

Main classes of background:

Vac

Reg

Vac00

Reg00

Misidentified K: Kl 0.090 0.003 K

0.11 ~0Scattered K: regenerator 0.073 0.25 1.13 collimator 0.010 0.010 0.12 0.09Total 0.100 0.087 0.48 1.23

Background levels (in %)

Page 10: A New Measurement of   from KTeV

Center-of-energy for K Events

• KS+ distribution used to model scattering background in K .

2tp

• Improvements in procedure revealed a mistake in the background estimation for the published result: Re() = 1.7.

Page 11: A New Measurement of   from KTeV

EK Dependence of Regenerator Scatters

Page 12: A New Measurement of   from KTeV

Yield after Background Subtraction

Vacuum Beam Reg. Beam

K 8,593,988 14,903,532

K00 2,489,537 4,130,392

Raw double ratio:

8593988 /149035320.96

2489537 / 4130392R

(no acceptance correction)

KL “KS”

Page 13: A New Measurement of   from KTeV

1997 Reconstructed Vertex z Distributions

Page 14: A New Measurement of   from KTeV

0.1% shift in E scale: ~3 cm shift in vertex; ~1 shift in

Page 15: A New Measurement of   from KTeV

Acceptance

Detailed Monte Carlo simulation based on measured detector geometry and response. Includes:• Accidental overlays• Full trigger simulation (L1,L2,L3)• For K00:

Geant-based shower library for CsI (showers cover 0.6750.675 m2)Detail photon veto simulation

• For K+-:Detailed drift chamber simulationMagnetic field mapCsI pion shower library

High statistics decay modes (e.g., K e,K 30) are used to check MC simulation.

Page 16: A New Measurement of   from KTeV

KTeV 1997* Data / Monte Carlo Comparison

* excludes 1997a data used in publication.

KL KLe

Page 17: A New Measurement of   from KTeV

KTeV 1997 Data / Monte Carlo Comparison

KL KL

Page 18: A New Measurement of   from KTeV

Calorimeter Energy Scale

Final energy scaleadjustment based on regenerator edge.

Energy scale depends on PK.

Applying an energy-independentscale shifts Re() by -0.5 compared to nominal method.

Page 19: A New Measurement of   from KTeV

Check E scale with different modes:K, K*KS,hadronic 2 production,K20 Dalitz, 30

Cross Checks of Energy Scale

Page 20: A New Measurement of   from KTeV

Systematic Uncertainties for 1997

Uncertainty in (10

)Source of uncertainty

from

from

0.62

0.16--

0.280.250.20

0.330.150.370.53

0.16

1.370.660.380.371.06

0.480.08

--0.26

Data collection: Trigger (L1/L2/L3)Event recon., backgrounds: Energy scale Calorimeter nonlinearity Detector calibration alignment Analysis cut variations Background subtractionDetector acceptance: Limiting apertures Detector resolution Drift chamber simulation Z dependence of acceptanceKaon flux, physics parameters: Reg-beam attenuation m, s

Regeneration phase, screening

0.190.240.31

TOTAL 2.32

Page 21: A New Measurement of   from KTeV

Calculating

0 0 0 0

0 0 0 0

N(Vac ) N(Reg )/

1 Acc(Vac ) Acc(Reg )Re( / ) 1 ,

N(Vac ) N(Reg )6/

Acc(Vac ) Acc(Reg )

Naively,

but regenerator beam is not purely KS.

Page 22: A New Measurement of   from KTeV

KL - KS Interference Downstream of Regenerator

KTeV Preliminary Results: 6 1

14

00

(5262 7.7(exp) 13(ext)) 10

(8967.1 3.5(exp) 4(ext)) 10

44.11 0.72 (stat) 1.1 (syst)

0.41 0.22 (stat) 0.53 (syst)

S

m s

s

Page 23: A New Measurement of   from KTeV

History of KS Lifetime Measurements

Page 24: A New Measurement of   from KTeV

History of m Measurements

Page 25: A New Measurement of   from KTeV

Re() = (19.8 1.7 (stat) 2.3 (syst) 0.6 (MC stat)) 10-4

Re() Result from 1997 Data Set

Page 26: A New Measurement of   from KTeV

Geometry-only Monte Carlo

KLKL+

• Using acceptance correction from MC with perfect detector resolution (only geometry) shifts Re( by 12 compared to full MC. • Correcting for observed data/MC z slope reduces shift to ~2 .

Page 27: A New Measurement of   from KTeV

Cross-check using reweighting method

• Provides check of Monte Carlo method• Statistically less significant than Monte Carlo method ().

Reweight KL decays to reg. beam distribution.

Page 28: A New Measurement of   from KTeV

Effect of Reweighting on Detector Illuminations

Page 29: A New Measurement of   from KTeV

KTeV

NA48

KTeV and NA48 Beams

Page 30: A New Measurement of   from KTeV

Reweighting Method Result

Based on preliminary study of correlation ofsystematic errors, difference between standard method and reweighting method is:

Re() = (1.5 2.1 (stat) 3 (syst))

Page 31: A New Measurement of   from KTeV

Improvements in Analysis

• CsI Calibration• Drift Chamber calibration and

alignment• Neutral backgrounds• Apertures• Attenuation m, S

Page 32: A New Measurement of   from KTeV

Update of Published Result (96-97a dataset)

Re() = (23.2 3.0 (stat) 3.2 (syst) 0.7 (MC stat)) 10-4

Page 33: A New Measurement of   from KTeV

Re() Cross Checks

Page 34: A New Measurement of   from KTeV

KTeV Results

• 1997 (independent from published result)

Re() = (19.8 1.7 (stat) 2.3 (syst)

0.6 (MC stat)) 10-4

• Updated 1996/1997a

Re() = (23.2 3.0 (stat) 3.2 (syst)

0.7 (MC stat)) 10-4

• Combined 1996+1997 Result

Re() = (20.7 1.5 (stat) 2.4 (syst)

0.5 (MC stat)) 10-4

= (20.7 2.8) 10-4

Page 35: A New Measurement of   from KTeV

Measurements of Re()

World ave. Re() = (17.2 )

(confidence level = 13%)

Page 36: A New Measurement of   from KTeV

Re() and Im() from Fermilab Experiments

Page 37: A New Measurement of   from KTeV

Conclusions

• KTeV results from 1996+1997 data:

Re() = (20.7 1.5 (stat) 2.4 (syst)

0.5 (MC stat)) 10-4

= (20.7 2.8) 10-4

New measurements of m, S, +, and • New world average:

Re() = (17.2 ) • Full KTeV data sample (96+97+99) will

reduce the statistical error on to

~ 1 10-4

significant work will be required to

reduce systematic error to similar level• Theory improvement needed to take full

advantage of this precision.