A Cryogenic Torsion Balance Test - Institute for Nuclear ... · Thank you everybody! To Frank...
Transcript of A Cryogenic Torsion Balance Test - Institute for Nuclear ... · Thank you everybody! To Frank...
![Page 1: A Cryogenic Torsion Balance Test - Institute for Nuclear ... · Thank you everybody! To Frank Fleischer especially, for his constant enthusiasm and patience To Blayne Heckel and Eric](https://reader034.fdocuments.us/reader034/viewer/2022042017/5e7555dbbf309f631b1d8c9a/html5/thumbnails/1.jpg)
A Cryogenic Torsion Balance Test
Daniel Dandurand with Frank Fleischer and Eöt-Wash Group University of Washington Physics REU Summer 2009
![Page 2: A Cryogenic Torsion Balance Test - Institute for Nuclear ... · Thank you everybody! To Frank Fleischer especially, for his constant enthusiasm and patience To Blayne Heckel and Eric](https://reader034.fdocuments.us/reader034/viewer/2022042017/5e7555dbbf309f631b1d8c9a/html5/thumbnails/2.jpg)
Outline
What is the Equivalence Principle? How has it been tested? Why use a torsion balance? Why use a cryogenic torsion balance? Experiment features My work on experiment Future of experiment
![Page 3: A Cryogenic Torsion Balance Test - Institute for Nuclear ... · Thank you everybody! To Frank Fleischer especially, for his constant enthusiasm and patience To Blayne Heckel and Eric](https://reader034.fdocuments.us/reader034/viewer/2022042017/5e7555dbbf309f631b1d8c9a/html5/thumbnails/3.jpg)
Equivalence Principle:
A uniform gravitational field is locally indistinguishable from a uniformly accelerated reference frame
![Page 4: A Cryogenic Torsion Balance Test - Institute for Nuclear ... · Thank you everybody! To Frank Fleischer especially, for his constant enthusiasm and patience To Blayne Heckel and Eric](https://reader034.fdocuments.us/reader034/viewer/2022042017/5e7555dbbf309f631b1d8c9a/html5/thumbnails/4.jpg)
The Universality of Free Fall (UFF) In uniform gravitational field,
particle trajectory independent of composition
![Page 5: A Cryogenic Torsion Balance Test - Institute for Nuclear ... · Thank you everybody! To Frank Fleischer especially, for his constant enthusiasm and patience To Blayne Heckel and Eric](https://reader034.fdocuments.us/reader034/viewer/2022042017/5e7555dbbf309f631b1d8c9a/html5/thumbnails/5.jpg)
History of UFF Tests Tests characterized by Eötvös parameter
Bounds on this parameter have been getting smaller and smaller
But, several theories beyond the Standard Model predict it should not be zero!
![Page 6: A Cryogenic Torsion Balance Test - Institute for Nuclear ... · Thank you everybody! To Frank Fleischer especially, for his constant enthusiasm and patience To Blayne Heckel and Eric](https://reader034.fdocuments.us/reader034/viewer/2022042017/5e7555dbbf309f631b1d8c9a/html5/thumbnails/6.jpg)
~1600: Galileo (dropping balls) η< 1 part in 100
~1680: Newton (pendulum periods) η< 1 part in 1000
1922: Eötvös (torsion balance) η< 5 parts in 1 billion
2008: Schlamminger, Choi, Wagner, Gundlach, Adelberger (rotating torsion balance) η< 3 parts in 10 trillion
![Page 7: A Cryogenic Torsion Balance Test - Institute for Nuclear ... · Thank you everybody! To Frank Fleischer especially, for his constant enthusiasm and patience To Blayne Heckel and Eric](https://reader034.fdocuments.us/reader034/viewer/2022042017/5e7555dbbf309f631b1d8c9a/html5/thumbnails/7.jpg)
How does a torsion balance work?
Two bodies hang from very thin torsion fiber
Sensitive to forces in horizontal plane
Even a miniscule difference in horizontal forces on test bodies creates noticeable torque
![Page 8: A Cryogenic Torsion Balance Test - Institute for Nuclear ... · Thank you everybody! To Frank Fleischer especially, for his constant enthusiasm and patience To Blayne Heckel and Eric](https://reader034.fdocuments.us/reader034/viewer/2022042017/5e7555dbbf309f631b1d8c9a/html5/thumbnails/8.jpg)
Source: “Tests of the Equivalence Principle”, Stephan Schlamminger
![Page 9: A Cryogenic Torsion Balance Test - Institute for Nuclear ... · Thank you everybody! To Frank Fleischer especially, for his constant enthusiasm and patience To Blayne Heckel and Eric](https://reader034.fdocuments.us/reader034/viewer/2022042017/5e7555dbbf309f631b1d8c9a/html5/thumbnails/9.jpg)
Common Features of Eöt-Wash Balances
Autocollimator used to measure deflection angle Source mass rotates relative to torsion pendulum Since gravitational field on Earth not actually uniform, pendulum must be designed so as not to couple strongly to gravity gradients (more on this later)
![Page 10: A Cryogenic Torsion Balance Test - Institute for Nuclear ... · Thank you everybody! To Frank Fleischer especially, for his constant enthusiasm and patience To Blayne Heckel and Eric](https://reader034.fdocuments.us/reader034/viewer/2022042017/5e7555dbbf309f631b1d8c9a/html5/thumbnails/10.jpg)
Advantage of Cryogenic Torsion Balance
Thermal noise is reduced with lower temperatures and higher quality factor Q of torsion fiber
Reducing temperature has been shown to increase Q in some fiber materials
Could reduce uncertainty in Eötvös parameter η by order of magnitude
![Page 11: A Cryogenic Torsion Balance Test - Institute for Nuclear ... · Thank you everybody! To Frank Fleischer especially, for his constant enthusiasm and patience To Blayne Heckel and Eric](https://reader034.fdocuments.us/reader034/viewer/2022042017/5e7555dbbf309f631b1d8c9a/html5/thumbnails/11.jpg)
Design Features
pendulum chamber cooled down to ~6 Kelvin
independent support for pulse tube cooler
air springs/flexible heat links help decouple vibration from pulse cooler
uses Sun/galactic center as source mass
![Page 12: A Cryogenic Torsion Balance Test - Institute for Nuclear ... · Thank you everybody! To Frank Fleischer especially, for his constant enthusiasm and patience To Blayne Heckel and Eric](https://reader034.fdocuments.us/reader034/viewer/2022042017/5e7555dbbf309f631b1d8c9a/html5/thumbnails/12.jpg)
Vacuum chamber
Vacuum pump
Pulse tube
cooler
Autocollimator view hole
Air springs
![Page 13: A Cryogenic Torsion Balance Test - Institute for Nuclear ... · Thank you everybody! To Frank Fleischer especially, for his constant enthusiasm and patience To Blayne Heckel and Eric](https://reader034.fdocuments.us/reader034/viewer/2022042017/5e7555dbbf309f631b1d8c9a/html5/thumbnails/13.jpg)
Close-up: Magnetic Damper Magnetic disks
(side view)
Aluminum damper disk
Torsion fiber
![Page 14: A Cryogenic Torsion Balance Test - Institute for Nuclear ... · Thank you everybody! To Frank Fleischer especially, for his constant enthusiasm and patience To Blayne Heckel and Eric](https://reader034.fdocuments.us/reader034/viewer/2022042017/5e7555dbbf309f631b1d8c9a/html5/thumbnails/14.jpg)
Challenges
Vibrations from pulse tube cooler (and other sources)
With Sun/galactic center as source mass, daily environmental changes cause problems (temperature, human traffic, etc.)
Gravity gradients
![Page 15: A Cryogenic Torsion Balance Test - Institute for Nuclear ... · Thank you everybody! To Frank Fleischer especially, for his constant enthusiasm and patience To Blayne Heckel and Eric](https://reader034.fdocuments.us/reader034/viewer/2022042017/5e7555dbbf309f631b1d8c9a/html5/thumbnails/15.jpg)
Gravity Gradients
When gravity field is not uniform, there can be torques on pendulum (even without EP violation)
Must design pendulum so coupling to nearby gradients as weak as possible
Source: Su, Yue. “A New Test of the Weak Equivalence Principle.” 1992 p.19.
![Page 16: A Cryogenic Torsion Balance Test - Institute for Nuclear ... · Thank you everybody! To Frank Fleischer especially, for his constant enthusiasm and patience To Blayne Heckel and Eric](https://reader034.fdocuments.us/reader034/viewer/2022042017/5e7555dbbf309f631b1d8c9a/html5/thumbnails/16.jpg)
Test Pendulum
Check to see if apparatus working as expected (only deflection should be from thermal noise)
No composition dipole Small low-order multipole moments
![Page 17: A Cryogenic Torsion Balance Test - Institute for Nuclear ... · Thank you everybody! To Frank Fleischer especially, for his constant enthusiasm and patience To Blayne Heckel and Eric](https://reader034.fdocuments.us/reader034/viewer/2022042017/5e7555dbbf309f631b1d8c9a/html5/thumbnails/17.jpg)
Design Features 120◦ rotational
symmetry Symmetric across
x-y plane Hollow
Attachment screw Aluminum body
90◦ gold-coated mirror
![Page 18: A Cryogenic Torsion Balance Test - Institute for Nuclear ... · Thank you everybody! To Frank Fleischer especially, for his constant enthusiasm and patience To Blayne Heckel and Eric](https://reader034.fdocuments.us/reader034/viewer/2022042017/5e7555dbbf309f631b1d8c9a/html5/thumbnails/18.jpg)
Future of Experiment
Use test pendulum to check noise levels, make modifications to experiment as necessary
Design experiment pendulum with composition dipole
Make new measure of EP violation
![Page 19: A Cryogenic Torsion Balance Test - Institute for Nuclear ... · Thank you everybody! To Frank Fleischer especially, for his constant enthusiasm and patience To Blayne Heckel and Eric](https://reader034.fdocuments.us/reader034/viewer/2022042017/5e7555dbbf309f631b1d8c9a/html5/thumbnails/19.jpg)
Thank you everybody! To Frank Fleischer especially, for his constant
enthusiasm and patience To Blayne Heckel and Eric Adelberger, both
busy men who always made time for my questions
To Todd, Ted, Will, Charlie, Swanson, and Jens, all of whom gave me bits of physics wisdom
To David and Hank for machine shop expertise To all of the friendly faces at CENPA To Wick Haxton, Deep Gupta and Warren
Buck for coordinating the program And to my REU friends. I had a great time.