A 50 MHz System for GMRT
description
Transcript of A 50 MHz System for GMRT
![Page 1: A 50 MHz System for GMRT](https://reader035.fdocuments.us/reader035/viewer/2022081513/568149ae550346895db6ec5d/html5/thumbnails/1.jpg)
A 50 MHz System for GMRT
N. Udaya Shankar
K. S. DwarakanathRaman Research Institute, Bangalore, INDIA
MWA Meeting, Canberra,
18-23 Jan 2009
![Page 2: A 50 MHz System for GMRT](https://reader035.fdocuments.us/reader035/viewer/2022081513/568149ae550346895db6ec5d/html5/thumbnails/2.jpg)
TEAM S. Amiri,
R. Somasekar, B.S. Girish, Arvind Nayak, Wenny Laus, S. Kasturi, Sujatha.
![Page 3: A 50 MHz System for GMRT](https://reader035.fdocuments.us/reader035/viewer/2022081513/568149ae550346895db6ec5d/html5/thumbnails/3.jpg)
Outline
Objectives of a 50 MHz system for GMRT.
Feed design.
Summary of observations with the new feed.
Direct voltage recording system.
Experiments with the direct voltage recording system in the interferometric mode.
Conclusions.
![Page 4: A 50 MHz System for GMRT](https://reader035.fdocuments.us/reader035/viewer/2022081513/568149ae550346895db6ec5d/html5/thumbnails/4.jpg)
Objectives of a 50 MHz system
Design and build feeds for operation at frequencies below about 100 MHz.
Carry out a low frequency survey of the sky visible to GMRT with arcmin resolution and unprecedented surface brightness sensitivity.
Make the survey results available to the astronomy community as an online resource.
Make the observing system available to GMRT user community.
![Page 5: A 50 MHz System for GMRT](https://reader035.fdocuments.us/reader035/viewer/2022081513/568149ae550346895db6ec5d/html5/thumbnails/5.jpg)
Survey Parameters
Assuming: – Bandwidth: 10 MHz, – System temperature: 4000 °K,– Synthesized beam: 1’, and – RMS sensitivity (4 hr, dual polarization):
2 mJy/beam (Thermal Noise)10 mJy/beam (Dynamic Range Limited)
A mosaic of about 300 pointings to cover the Northern sky requires 1200 hrs of observation– Primary beam area of 0.03 steradians.
![Page 6: A 50 MHz System for GMRT](https://reader035.fdocuments.us/reader035/viewer/2022081513/568149ae550346895db6ec5d/html5/thumbnails/6.jpg)
NameSky
coverage(steradians)
Telescope time (hrs)
Surveying speed (hrs/sr)
RMS noise
(in mJy)
Equivalent RMS noise at 50 MHz (1-σ in mJy)
GMRT 50 MHz
3 1200 128 2 (10) 2 (10)
GMRT-MWA 5.9 7200 364 0.14 0.35
NVSS 10.3 2700 262 0.15 7.2
WENSS 960 305 4 18
VLSS 3 900 95 100 137
Survey comparison
Larger collecting area and higher antenna efficiency means the low frequency GMRT system will be more sensitive than the 74 MHz VLA system.
![Page 7: A 50 MHz System for GMRT](https://reader035.fdocuments.us/reader035/viewer/2022081513/568149ae550346895db6ec5d/html5/thumbnails/7.jpg)
Sensitivity Vs Angular size
55 confusion confusion
![Page 8: A 50 MHz System for GMRT](https://reader035.fdocuments.us/reader035/viewer/2022081513/568149ae550346895db6ec5d/html5/thumbnails/8.jpg)
Development of high dynamic range, interference tolerant receivers.
Detection and mitigation of radio frequency interference.
Calibration issues arising out of ionospheric effects.
Problems of imaging wide-fields with non-coplanar baselines.
Deconvolution of images with large scale features.
Main challenges
![Page 9: A 50 MHz System for GMRT](https://reader035.fdocuments.us/reader035/viewer/2022081513/568149ae550346895db6ec5d/html5/thumbnails/9.jpg)
A Low Frequency Feed for GMRT
Wish list: Covering the frequency range 30 MHz to 90
MHz.
Sky noise dominates the system temperature (Tsky> 5 Tsys).
Reasonable aperture efficiency (0.5 < ap < 0.7).
Symmetrical E & H plane patterns.
Physical dimension is suitable for mounting it along with one of the existing feeds on the GMRT antenna turret, with minimum interference to its operation.
![Page 10: A 50 MHz System for GMRT](https://reader035.fdocuments.us/reader035/viewer/2022081513/568149ae550346895db6ec5d/html5/thumbnails/10.jpg)
Feed Design
Simulations were done to determine the configuration which cause minimum interference to the operation of the existing feed.
After field trials, it was decided to co-locate the new feed with the existing 327 MHz feed.
The desired frequency of operation (30 to 90 MHz) was chosen to:– Facilitate imaging in the band protected for Radio
Astronomy around 38 MHz,– Have an overlap with the 74 MHz system on VLA,
and – Minimize the RFI due to the FM Radio band
starting around 90 MHz.
![Page 11: A 50 MHz System for GMRT](https://reader035.fdocuments.us/reader035/viewer/2022081513/568149ae550346895db6ec5d/html5/thumbnails/11.jpg)
Feed Design
Boxing ring configuration chosen since it has more symmetric radiation characteristics (E and H plane patterns) than a single dipole like feed.
Following parameters were tuned:– Distance between two parallel dipoles in the
boxing ring.– Shape of the dipoles to achieve the required
bandwidth.– Height of dipoles above the reflector.– Impedance mismatch at frequencies away from
the resonance.
![Page 12: A 50 MHz System for GMRT](https://reader035.fdocuments.us/reader035/viewer/2022081513/568149ae550346895db6ec5d/html5/thumbnails/12.jpg)
Present Status
The first phase of the project :
A system for 4 GMRT antennas has been designed, built and installed and its performance has been examined.
The design would be developed further, if necessary, based on our experience.
Four folded V-dipoles each of length ~2.4m. Its feed point is positioned 1m above a 3m X 3m square reflector with a 50mm mesh.
The feed co-located with existing 327 MHz feed
![Page 13: A 50 MHz System for GMRT](https://reader035.fdocuments.us/reader035/viewer/2022081513/568149ae550346895db6ec5d/html5/thumbnails/13.jpg)
Summary of observations
GMRT antennas C04, C11, E02 & W02 equipped with new feeds.
3C sources observed: Cyg-A, Cas-A and a few other sources.
Maximum EW baseline: 6 km.
C04-C11 NS baseline: ~0.5 km.
Aperture efficiency:
– ~65% (55 MHz)
– ~30% (40 MHz)
C11
C04
E02W02
![Page 14: A 50 MHz System for GMRT](https://reader035.fdocuments.us/reader035/viewer/2022081513/568149ae550346895db6ec5d/html5/thumbnails/14.jpg)
Observed several 3C sources.
Over an hour of observing of Cyg-A, the cross correlation coefficients showed:– A steady behaviour as has been seen at other
observing bands of GMRT. – Measured rms of ~6% on the visibilities at 55 MHz
implies an rms of ~12° in closure phases and ~12% in closure amplitudes.
– Closure phases showed an rms of 1.4° and the closure amplitudes showed an rms of 7%.
– Observed rms in the closure quantities are much less implying that a significant part of the rms in the visibilities are due to systematics.
Summary of observations
![Page 15: A 50 MHz System for GMRT](https://reader035.fdocuments.us/reader035/viewer/2022081513/568149ae550346895db6ec5d/html5/thumbnails/15.jpg)
Closure phases
Looking at one good channel across 1 hr time.
RMS: ~1.5°.
Ph
ase
(Deg
rees)
Baseline: C04-E02
Baseline: C11-E02
Baseline: C04-C11
Time (Hours)
![Page 16: A 50 MHz System for GMRT](https://reader035.fdocuments.us/reader035/viewer/2022081513/568149ae550346895db6ec5d/html5/thumbnails/16.jpg)
Direct voltage recording system
Digitize a signal of ~5 MHz bandwidth centred at 55 MHz.
Data rate: ~80 GB/hr.
Systems synchronized using signals from GPS-disciplined Rubidium oscillators.
Two direct voltage recording systems were installed at C04 and C11 antenna bases.
![Page 17: A 50 MHz System for GMRT](https://reader035.fdocuments.us/reader035/viewer/2022081513/568149ae550346895db6ec5d/html5/thumbnails/17.jpg)
Direct voltage recording system
Laboratory Test Setup
Setup At GMRTAntenna Base
8-bit A/DConverter
8-bit A/DConverter
Stored OnHard Disk
Stored OnHard Disk
DelayCorrection
Offl
ine D
ata
Pro
cessin
g
DelayCorrection
Visibilities PostIntegration
Rf Rf
8192-pointFourier
Transform
8192-pointFourier
Transform
~80 GB/Hr
![Page 18: A 50 MHz System for GMRT](https://reader035.fdocuments.us/reader035/viewer/2022081513/568149ae550346895db6ec5d/html5/thumbnails/18.jpg)
Typical cross power dynamic spectra ~4000 channels. Spectral resolution of 1.36 KHz.
~4 min of data. Each time frame with ~1 second integration.
Notice the RFI stripes.
Only ~2000 central channels marked in plot used for analysis.
~2000 central channels used for analysis.
![Page 19: A 50 MHz System for GMRT](https://reader035.fdocuments.us/reader035/viewer/2022081513/568149ae550346895db6ec5d/html5/thumbnails/19.jpg)
Typical Self & Cross spectra
1200 1400 1600 1800 2000 2200 2400 2600 2800 3000-30
-25
-20
CHANNEL INDEX
SELF ANT-1
1200 1400 1600 1800 2000 2200 2400 2600 2800 3000-30
-25
-20
CHANNEL INDEX
SELF ANT-2
1200 1400 1600 1800 2000 2200 2400 2600 2800 3000-34
-32
-30
-28
CHANNEL INDEX
Un-NORM CROSS
Integrated for ~4 min, only central ~2000 channels shown.
Notice the comb in self power of Antenna-2 (C11) and is relatively affected more by RFI.
![Page 20: A 50 MHz System for GMRT](https://reader035.fdocuments.us/reader035/viewer/2022081513/568149ae550346895db6ec5d/html5/thumbnails/20.jpg)
RFI Scenario in ~1s integrated visibility for ~4 min data.
~0.5% RFI points above 4-σ.
RFI Scenario
100
101
102
100
200
300
400
500
600
Duration of interference (seconds)
Number of interference points
![Page 21: A 50 MHz System for GMRT](https://reader035.fdocuments.us/reader035/viewer/2022081513/568149ae550346895db6ec5d/html5/thumbnails/21.jpg)
Dynamic spectra after RFI excision
Central ~2000 channels.
Notice, the vertical RFI stripes (across time) have disappeared.
![Page 22: A 50 MHz System for GMRT](https://reader035.fdocuments.us/reader035/viewer/2022081513/568149ae550346895db6ec5d/html5/thumbnails/22.jpg)
Structures in Time-Frequency
Period: ~ 45 s
Variations: ± 5%
~4 min integrated spectra.
RFI channels: ~20%
![Page 23: A 50 MHz System for GMRT](https://reader035.fdocuments.us/reader035/viewer/2022081513/568149ae550346895db6ec5d/html5/thumbnails/23.jpg)
Our experience shows that a multi-resolution filter provides a possible optimal solution for interference mitigation.
Using this approach we are in the process of analysing simultaneous observations carried out using:
– GMRT hardware correlator,
– New GMRT software correlator which is under testing, and
– RRI direct voltage recording system.
We hope these investigations will throw more light on the effect of systematics on thermal noise.
![Page 24: A 50 MHz System for GMRT](https://reader035.fdocuments.us/reader035/viewer/2022081513/568149ae550346895db6ec5d/html5/thumbnails/24.jpg)
Conclusions
We have successfully designed, installed and tested a 50 MHz system on 4 GMRT antennas.
Aperture efficiency is ~65% in the 50 MHz band.
Test observations indicate satisfactory performance of the feed system.
Investigations are under way to understand the mitigation of systematics and RFI to achieve performance limited by thermal noise.
![Page 25: A 50 MHz System for GMRT](https://reader035.fdocuments.us/reader035/viewer/2022081513/568149ae550346895db6ec5d/html5/thumbnails/25.jpg)
Acknowledgements
We thank our colleagues at GMRT site and NCRA for their excellent support.
![Page 26: A 50 MHz System for GMRT](https://reader035.fdocuments.us/reader035/viewer/2022081513/568149ae550346895db6ec5d/html5/thumbnails/26.jpg)
![Page 27: A 50 MHz System for GMRT](https://reader035.fdocuments.us/reader035/viewer/2022081513/568149ae550346895db6ec5d/html5/thumbnails/27.jpg)
![Page 28: A 50 MHz System for GMRT](https://reader035.fdocuments.us/reader035/viewer/2022081513/568149ae550346895db6ec5d/html5/thumbnails/28.jpg)
Integrated for ~4 min, only central ~2000 channels shown.
First row:
Second row: Variations across time.
Structures in Time-Frequency
![Page 29: A 50 MHz System for GMRT](https://reader035.fdocuments.us/reader035/viewer/2022081513/568149ae550346895db6ec5d/html5/thumbnails/29.jpg)
Aperture efficiency Cyg-A (Sep 07 observations)
Baseline- C04:C11
Centre frequency: 55 MHz
Aperture efficiency: ~65 %
![Page 30: A 50 MHz System for GMRT](https://reader035.fdocuments.us/reader035/viewer/2022081513/568149ae550346895db6ec5d/html5/thumbnails/30.jpg)
Aperture efficiency Cyg-A (Sep 07 observations)
Baseline- C04:C11
Centre frequency: 38 MHz
Aperture efficiency: ~30 %
![Page 31: A 50 MHz System for GMRT](https://reader035.fdocuments.us/reader035/viewer/2022081513/568149ae550346895db6ec5d/html5/thumbnails/31.jpg)
![Page 32: A 50 MHz System for GMRT](https://reader035.fdocuments.us/reader035/viewer/2022081513/568149ae550346895db6ec5d/html5/thumbnails/32.jpg)
![Page 33: A 50 MHz System for GMRT](https://reader035.fdocuments.us/reader035/viewer/2022081513/568149ae550346895db6ec5d/html5/thumbnails/33.jpg)
![Page 34: A 50 MHz System for GMRT](https://reader035.fdocuments.us/reader035/viewer/2022081513/568149ae550346895db6ec5d/html5/thumbnails/34.jpg)
![Page 35: A 50 MHz System for GMRT](https://reader035.fdocuments.us/reader035/viewer/2022081513/568149ae550346895db6ec5d/html5/thumbnails/35.jpg)
![Page 36: A 50 MHz System for GMRT](https://reader035.fdocuments.us/reader035/viewer/2022081513/568149ae550346895db6ec5d/html5/thumbnails/36.jpg)
![Page 37: A 50 MHz System for GMRT](https://reader035.fdocuments.us/reader035/viewer/2022081513/568149ae550346895db6ec5d/html5/thumbnails/37.jpg)
![Page 38: A 50 MHz System for GMRT](https://reader035.fdocuments.us/reader035/viewer/2022081513/568149ae550346895db6ec5d/html5/thumbnails/38.jpg)
![Page 39: A 50 MHz System for GMRT](https://reader035.fdocuments.us/reader035/viewer/2022081513/568149ae550346895db6ec5d/html5/thumbnails/39.jpg)
![Page 40: A 50 MHz System for GMRT](https://reader035.fdocuments.us/reader035/viewer/2022081513/568149ae550346895db6ec5d/html5/thumbnails/40.jpg)
![Page 41: A 50 MHz System for GMRT](https://reader035.fdocuments.us/reader035/viewer/2022081513/568149ae550346895db6ec5d/html5/thumbnails/41.jpg)
Surface Brightness Sensitivity of other surveys
Surface Brightness sensitivity of MRT
7 X 10 (-22) Watts/m2/Hz/ Ster (Theoretical)
2 X 10(-21) Watts/m2/Hz/ Ster (Achieved)
4.2 X 10 (-22) Watts/m2/Hz/ Ster (Eq at 1.4 GHz)
Typical SB of SNR = 1.5 X 10 (-21) Watts/m2/Hz/ Ster
SNR cat complete = 10(-20) Watts/m2/Hz/ Ster at 1 GHz
VLA 4mass 100 mJy/beam
Beam Size 80’’