A) 390-5109 · 2014-01-15 · HID - CORE & COIL BALLASTS HIGH PRESSURE SODIUM _ Fft2l (60 Hz.,...
Transcript of A) 390-5109 · 2014-01-15 · HID - CORE & COIL BALLASTS HIGH PRESSURE SODIUM _ Fft2l (60 Hz.,...
HID - CORE & COIL BALLASTS
HIGH PRESSURE SODIUM _ Fft2l(60 Hz., MINIMUM STARTING TEMPERATURE -40°F OR
InputVolts
Catalog1"Number
CircuitType
WattsInput
Max*Input
Current
MomOpenCircuitVoltage
1000 Watt Lamp, ANSI Code S52120220277
480
120/208/240/277
120/208/240/277
120/277/347
12V277/347
71A870371A87J371A8733
71A8743
71A8743-001
71A8793
71A8773-001
71A87A3
71A87A3-001
CWA
CWA
CWA
CWA
CWA
CWA
1100
1100
1100
1100
1100
1100
9.25.04.0
2.3
9.5/S.5/4.8/4.2
9.5/S.5/4.8/4.2
9.5/4.2/3.3
9.5/4.2/3.3
435
435
435
435
435
435
FuseRating(Amps)
WiringDia
251510
6
25/1 5/10/10
25/1 5/10/10
25/15/10
25/15/10
M
M
M
M
M
M
Dimensions
Finrig
8a
8a
8a
8a
8a
8a
^
-40°C) « J»
Non-PCB Capacitor(Page 158-159)
Mfd MinVolt
Dry Film
Dla(in)
3.8
3.8
3.8
3.8
3.9
3,"
5.8
5.8
5.8
5.8
5.9
5.9
26
26
26
26
26
26
525
525
525
525
525
525
—
—
—
—
—
Ht(in)
Oil Filled
Oval(in)
Ht(in)
TotalWeight(Ibs)
—
—
—
—
—
—
1.75
1.75
1.75
1.75
1.75
1.75
5.25
5.25
5.25
5.25
5.25
5.25
28.0
28.0
28.0
28.0
28.0
28.0
Ignitor ft(Page 160-163)
PartNumber
LI571-H5*
LI571-H5*
LI571-H5*
LI571-H5*
LI571-H5*
LI571-H5*
MaxDlstTo
Lamp(ft)
U.L.Bench
TopRiseCode1029
(M115)
2
2
2
2
2
2
BCC
C
C/B/C/C
C/B/C/C
C/C/C
c/C/C
t Ordering information:Replacement/retrofit ballast kits indicated by bold type with suffix -001.Refer to pages 117-120.Original equipment ballasts - add proper suffix to catalog number:
-500 includes core & coil with oil-filled capacitor-510 includes core & coil with welded bracket and oil-filled capacitor-600 core & coil only (no capacitor)-610 core & coil with welded bracket (no capacitor)
• For CWA circuits, figure is operating current.ttEach ballast requiring an ignitor is furnished as standard with the Short
Range ignitor model shown for use within fixtures. If a Long Range ignitoris required for remote mounting, specify on order. See pages 160-163 foradditional information.
* Equipped with an auto-reset thermal protector to prevent ignitor from over-heating in the event of lamp failure.
* Canadian replacement/retrofit ballast kit indicated by bold type.Refer to pages 121 & 122.
A D V A N C E , 1 0 2 7 5 W E S T H I G G I N S R O A D , R O S E M O N T , I L 6 0 0 1 8 . T E L : ( 8 4 7 ) 3 9 0 - 5 0 0 0 , F A X : ( 8 4 7 ) 3 9 0 - 5 1 0 9 A 155
HIGH INTENSITY DISCHARGE BALLASTS
Encapsulated Core & Coil RAi • AoT nflTF ANn TCMPFRATMRF rnnpsWhere quiet performance is required, the standard open core & coil
ballasts are encapsulated (potted) in a cube-shaped steel can utilizingClass H (180°C) polyester compound. These ballasts carry a Class Anoise rating up through 175 watts and Class B tor 250 and 400 watts.As with the open core & coil, the capacitor (and ignitor where included)are mounted separately within the fixture.
Fluorescent Can (F-Can)For indoor commercial applications of HID lighting such as offices,
schools and retail stores, ballast noise must be minimized. Ballasts forthese fixtures are most often encased and potted in fluorescent ballasttype cans and utilize Class A (90°C) asphalt insulating materials (thesame as used in fluorescent lamp ballasts).
The Advance line of F-can ballasts comes in two dual-voltage con-figurations: 120/277 volt for the US market, and 120/347 volt for theCanadian market. Each unit has built-in, automatically resetting, ther-mal protectors which disconnect the ballast from the power line in theevent of overheating. All units are high power factor and include thecapacitor within the can. All models for high pressure sodium and low-wattage metal halide lamps also include the ignitor in the can.
Rallact 1 ahplDdlldol LauclXk-^» — ^^*^ ^^-— - Catalog Number
^^^r^lujxT^x. ^^^x^^%-C-VX./\ ^^e^S^ /X
/ /K. ^^^xCX^ Temperature
jf 1 Y^*~^ ^°^e
jr 1^1 ^*)t ^"^/ \ f /\ V^Date Code
1 » IJL. Kl * \ **'amP
i vT 1 I ^P ==^ i1 -jV JgglTl ^^W
^s< !\ £v^""P~T'""'>^y^>VO^JL 1 J- ^ f
Altprnatp Pncitinnc fnr ^^^^^_ _ __^£^^ .^^nllGllldlG rUolllUIIO 1UI ^^^^-^_— *y ^f
Date Stamo Code ^^ r. ^^
ADVANCE ® HID Core & Coil ballasts are date stamped on either theIndoor Enclosed top surface or the side surface of the ballast core. The four-digit number
These units are designed for use indoors where the ballast must bemounted remotely from the luminaire. They are most typically used infactories where the luminaire may be mounted in a high-bay where very
represents the week and year of manufacture. The first two numbersndicate the week and the last two indicate the year the ballast wasmanufactured. The example shows a ballast manufactured during the
high ambient temperatures may be experienced. In these instances, the 36th week of 1989. The three letters are an Advance factory code.remotely-mounted ballast operates cooler, subsequently providinglonger life because it is away from both the heat of the ceiling ambientand lamp heat within the fixture.
The case contains the core & coil potted in a Class H (180°C) heat-dissipating resin. The capacitor(s) and ignitor are contained within aseparate compartment. Knockouts in both ends of the case facilitatehook-up in the most convenient manner. Wall mounting is accom-plished through flanges on the top and bottom of the case. The ballastis a UL Listed product.
Outdoor WeatherproofWeatherproof ballasts are designed for remote, pole-mounting out-
door applications under all weather conditions. They may also benlj)f"*pH inQirip nf 3 tr^incf nrmpr nnlp hscp hut PQTP mi iQt hp tnkpn tnjJluLcU II loluw Ul a II at lolUI 1 1 Icl fJUIC UcloC, UUL UdIC IIIUol Uc Icmcl I LU
avoid areas prone to flooding because weatherproof ballasts are notwater-submersible.
The core & coil with its capacitor and ignitor (where required) arefirmly mounted to the heat-sink base. An aluminum cover is placed overthe core-&-coil assembly and is bolted with a weather-tight gasket tothe base. An integral 1" threaded nipple with locknut facilities hook-upto electrical conduit or to the mounting bracket when used on a pole.The weatherproof ballast may also be placed nipple-up, with a drip loopin the leads, inside a pole base.
PostlineLantern-type fixtures mounted on slender poles often require ballasts
which will fit into these poles. Special, elongated core & coil ballasts arepotted in resin in cylindrical cans having a 2.55" outside diameter. Allinclude leads necessary for direct connection to a photocell.
The capacitor and ignitor (where required) are included within thiscan. A Vz" threaded nipple is used for vertical mounting, and leadsextend from both ends of the can for ease of installation. The inputleads to the ballast also provide for proper connection to the photocellif such is included within the fixture.
To help prevent overheating, one to three feet of air space should beallowed in the pole above the ballast, and the ballast should be posi-tioned against the post interior wall to provide a heat-sink. All unitsrated 100W and above now include a mounting kit consisting of an 18"chain to hang the ballast within the pole and a spring clip to force theballast's cylindrical can to make line contact with the pole's interiorsurface to maximize heat transfer, thus prolonging the ballast life.
The ballast's UL Bench Top Rise Temperature Code is shown on theabel (see below).
UL BENCH TOP RISE TEMPERATURE CODETo facilitate UL inspection, each ballast's UL Bench Top Rise
Temperature Code is shown on the Advance Core & Coil ballast label as1029X, where 1029 is the UL Standard for HID Ballasts, and the X is thetemperature code: A, B, C, etc. If a fixture is UL listed for 1029C, thenautomatically, all ballasts with an A, B, or C temperature classificationare acceptable for use within that same fixture.
H
UL Bench Top Rise Temperature Range for •Letter Code Class H (180°C) Ballasts 11 ' •
A less than 75°CB 75°C < 80°Cr 8f)°r < JWT\J OU O x Q*J \J
D 85°C < 90°C
E 90°C < 95°C_ f\rnr\ J r\nnr\F 9 5 C < 1 0 0 C
etc. etc.
CERTIFICATIONS
® Indicates ballast is listed by Underwriters Laboratories,Inc. in accordance with UL 1029 Standard for HID Ballasts.
„ Each ballast is marked appropriately.
— . Indicates ballast is component recognized by Underwriterss rla Laboratories, Inc. in accordance with UL 1029 Standard for
HID Ballasts. Each ballast is marked appropriately.
t Indicates ballast is certified by Canadian StandardsAssociation in accordance with CAN/CSA-22.2 No. 74-92.Each ballast is marked appropriately.
^^ All HID Ballasts are designed and manufactured inSSZifvSf accordance with the American National Standards^y^ L Institute Standard for HID Ballasts, ANSI C82.4.
ADVANCE, 10275 WEST HIGGINS ROAD, ROSEMONT, IL 60018. TEL: (847) 390-5000, FAX: (847) 390-5109 A 115
HID - CORE & COIL BALLASTS
HIGH PRESSURE SODIUM(60 Hz., MINIMUM STARTING TEMPERATURE -40°F OR -40°C)
InputVolts
Catalog1'Number
CircuitType
WattsInput
Max*Input
Current
NornOpenCircuitvoltage
FuseRating(Amps)
WiringDia
Dimensions
Finriy
SH**w ^jyNon-PCB Capacitor
(Page 158-159)
Mid
430 Watt Lamp, ANSI Code S145 (SON AGRO-Philips)120/
208/240
277/347/480
71A85E6
71A85F6
CWI
CWI
490
490
5.2/3.0/2.6
? 3/
1.8/1.3
200
200
15/10/7
11
5/5
Y
V
2
2
2.6
2.6
4.1
4.1
48
48
600 Watt Lamp, ANSI Code S106
2018/240 71A85E5 | CWA
277/347/480
71A85F5 CWA
670 ai£g 22°l I665 2.5/
2.0/1.4230
15/9/8
715/4
M
M
8a
8a
3.2
3.2
5.1
5.1
MinVolt
300
300
Dry Film
Dia(in)
1.75
1.75
Ht(in)
Oil Filled
Oval(in)
Ht(in)
TotalWeight(Ins)
Ignitor tt(Page 160-163)
PartNumber
MaxDistTn
Lamp(«)
U.LBench
TopRiseCode1029
(PB115)
5.15
5.15
—
—
—
—
15.0
15.0
LI501-H4
LI501-H4
15 C/
I E/D
15p/
C/B
2 Capacitor Set:[40[24
non300
1751.75
5153.75]
—
—
—
—
22.5
23.0
LI561-H5
LI561-H5
2 A/A/B
5 I N& I A/A
750 Watt Lamp, ANSI Code S111120/
208/240
277/347/480
71A86E5
71A86F5
CWA
CWA
840
840
6.8/4.0/3.5
3.1/2.5/1.8
220
225
20/10/10
10/10/5
Mi
M
8a
8a
3.2
3.2
5.1
5.1
2 Capacitor Set:[40[35
280280
1./h1.75
5.155.1 5j
—
—
—
—
22.5:
23.0
LI561-H5
LI561-H5
5
5
D/E/E
E/D/D
t Ordering information:Original equipment ballasts - add proper suffix to catalog number:-500D includes core & coil with dry-film capacitor-510D includes core & coil with welded bracket and dry-film capacitor-600 core & coil only (no capacitor)-610 core & coil with welded bracket (no capacitor)
• For CWA and CWI circuits, figure is operating current.ttEach ballast requiring an ignitor is furnished as standard with the Short
Range ignitor model shown for use within fixtures. If a Long Range ignitoris required for remote mounting, specify on order. See pages 160-163 foradditional information.
a Hales cleared lor
#10 thru-bolts
Fig. 8a(4' /4"x6"core)
Fig. MFig.Y
4 Holes cleared for
»10 thru-bolts
I y&^^ "">'"•
^T/ Fig. 2(4' /4"x43 /4"core)
Fig. V
12I,
Bracket *3,i
BallastDimensions Fig
2
8a
L
6.5
7.8
W
1.25
4.50
M
5.75
6.75
S
0.28
0.31
154 XJ^ A D V A N C E , 1 0 2 7 5 WEST H I G G I N S R O A D , R O S E M O N T , IL 6 0 0 1 8 . T E L : ( 8 4 7 ) 3 9 0 - 5 0 0 0 , FAX: ( 8 4 7 ) 3 9 0 - 5 1 0 9