FOR TRAINING PURPOSE ONLYwww.amevoice.com
- 1 -
A-320
FAULT
VERIFICATION
AND
LINE
MAINTENANCE
HANDBOOK
FOR TRAINING PURPOSE ONLYwww.amevoice.com
- 2 -
For Reference OnlyAir Deccan Eff List:
001=DKZ---002=DKY---003=ADT---004=ADS---005=DKR---006=DKS---007=DKT008=ADR---051=ADX---052=ADY---053-ADZ---101=DKW---102=DKX---115=DNZ151=ADV---152=ADW---201=DKV--202=DKU--203=ADU
Note: (***) Indicates Specific Setup notes: Note: (AOG) Indicates CB can be reset on Ground Only All others can be reset In-flight or on Ground Ref: M/M 31-51 – 31-60 for Details on Messages Ref: TSM 24-00-00-810-818 for Current Computer Reset’s
(00-00) Beside C/B #s indicate AC Effectivity (Specific)
FOR TRAINING PURPOSE ONLYwww.amevoice.com
- 3 -
This Guide is Provided For Reference Only
Always Refer to the Current TSM
If you have a Confirmed Fault
Document It
ATA
System or Fault Reset CB / Switch Time
21 Cabin Pressure Controller CPC 1-----D-9CPC 2-----Y-22
(1) Min
21 Avionics Equip Vent Comp
AC/Avion Vent Ctl --- D-5 –D-6 Mon---Y-17
30 Sec
21 Cargo Ventilation Fwd Cargo Vent Ctl ---C-8 Fan –T-22Aft Cargo Vent & Heat Fan ---S-22Aft Cargo Cont (Mont) ---------C-7
10 Sec
21 Pack Controller
Pack #1 Temp Ctl – X-21—X-22—Y-18—Y-19Pack #2 Temp Ctl – W-21—W-22—Y-20--Y-21***Packs Off , Pack FCV-(Closed)
30 Sec
21Zone Controller
AC Zone Temp Cont SystemV-17 -----V-18------V-19-----V-20***Resetting with Eng Running will generate FADEC Warnings
30 Sec
21 Hot Air Valve Reset Hot Air (P/B) 10 Sec
21 Air Pack Regulator Fault Y-18 ---Y-20 ----(051-149)X-22---Y-18---X-21---D-8 (All Others)Test: Zone Controller
30 Sec
21 Vent Avionics Faults& Extract Faults
Avionics Vent Mont –-----Y-17If no Help ------D-5 & D-6If no Help ------Reset (Extract Fan)
30 Sec
FOR TRAINING PURPOSE ONLYwww.amevoice.com
- 4 -
21 Trim Air Valve (Msg)Zone Temp Ctl –(Sys 1 AC)-----V-17 (Sys 2 AC)-----V-18 (Sys 1 DC)-----V-19 (Sys 2 DC)-----V-20
30Sec
FOR TRAINING PURPOSE ONLYwww.amevoice.com
- 5 -
ADDITIONAL FAULTS21
Air Pack Overheat – Compressor Outlet temp (which is controlled by the Pack FCV-----------------------------------------------------------------------------------------------------Air Pack Fault – Pack Valve disagree with the p/b switch position or the compressor outlet temperature.-----------------------------------------------------------------------------------------------------Air Pack Off – Pack is selected Off-----------------------------------------------------------------------------------------------------Air Pack Regulation Fault – Pack Controller (channel failure)-----------------------------------------------------------------------------------------------------Air Pack 1 & 2 Fail – Both Packs Failed-----------------------------------------------------------------------------------------------------Condition Duct Overheat – Duct Temp higher than 190 deg F (Pressure Reg Valve and Trim Air Valves close)-----------------------------------------------------------------------------------------------------Condition Hot Air Fault – Hot air Pressure Regulating Valve disagrees with the p/b switch position-----------------------------------------------------------------------------------------------------Condition Trim Air System – Trim Air Fault-----------------------------------------------------------------------------------------------------Condition Zone Regulator Fault – Primary or Secondary Zone Controller Failure-----------------------------------------------------------------------------------------------------Alternate Mode Indication (on ECAM) – Primary Zone Controller Fault
Hot Air P/B (Fault Light) –Indicates that the duct temp O/H(temp above 88 deg C) HAV & TAV close automatically(Fault Light goes off when temp drops below 70 deg C &The (HAV) is selected off.
FOR TRAINING PURPOSE ONLYwww.amevoice.com
- 6 -
FOR TRAINING PURPOSE ONLYwww.amevoice.com
- 7 -
FOR TRAINING PURPOSE ONLYwww.amevoice.com
- 8 -
ATA System or Fault Reset CB / Switch Time
22 FMGC
***ADIRUs ----------Aligned***FDs ----------------OffFMGC 1 --------------B-2FMGC 2 --------------M-17***C/B Out for 5 sec / In (B-4) 10***(Only 1 Sys @ a time in Flt)
5Secto10
Sec
22 FMGC ----- (AOG)
***Engines ----------Off***FDs ---------------OffFMGC 1 -------------B-2FMGC 2 -------------M-17***Pull Both C/Bs
10Sec
22 Auto Pilot (Faults) Reset FMGC as Above 10Sec
22 FAC --------(AOG)
***Engines ----------OffFAC 1 -------------B-3----B-4FAC 2 -------------M-18--M-19***With Hyd (ON) Yaw Damp is also tested.***Cycle FAC P/B 1st
30Sec
22 Rudder Trim (Fault) (AOG) Reset FAC System as Above 30Sec
22 Rudder Travel Limit (AOG) Reset FAC System as Above 30Sec
22 Dual Cat III (Msg) (AOG) Reset FAC System as Above 30Sec
22 MCDU (Faults) MCDU 1 -------------B-1MCDU 2 -------------N-20
10Sec
22 Flight Control Unit (FCU) (Faults) ------(AOG)
***Both FD’s -------------OffFCU 1 --------------- B-5FCU 2 ----------------M-21*** If 1st reset unsuccessful , retry for 7 Min*** If reset Successful (check) target & Baro References are shown
10SecOr(7)
Min
22 Wind Shear (Det) Fault Reset FAC as above XX
FOR TRAINING PURPOSE ONLYwww.amevoice.com
- 9 -
22 Auto Flight YAW DAMPER (Fault)
***Green & Yellow Hyd-----ONFAC 1 --------B-4FAC 2 --------M-19
10Sec
FOR TRAINING PURPOSE ONLYwww.amevoice.com
- 10 -
ATA System or Fault Reset CB / Switch Time
23 HF System HF 1 ------------HA-14 10Sec
23 VHF System
VHF 1 ----------G-9VHF 2 ----------L-4VHF 3 ----------L-5
10Sec
23
ACP***If Freq wont change Try Resetting FMGCs
ACP 1 ----------G-6ACP 2 ----------G-7ACP 3 ----------M-2
10Sec
23 RMPOr Frozen RMP
*** Reset ea RMP Separately (off – 5 Sec –On) *** If no HelpRMP 1 ---------G-10RMP 2 ---------L-2RMP 3 ---------L-3
(2)Min
23 CIDS (Faults)***(AOG) Pull All:***(Inflight) Reset (1) at a Time:
***C/B Loc Vary by A/C
*** Pull C/Bs in order: (All Others)G-2—M-5—G-5—G-4—G-3—M-13—M-12,
M-11—M-10--M-9—M-8—M-7—M-6—Q-14
*** Reset C/Bs in order: (All Others)M-13—M-12—M-11—M-10—M-9—M-8—M-7,M-6—Q-14—G-5—G-4—G-3—M-5—G-2
*** Pull C/Bs in order: (001—049) – (151-300)G-1—M-5—G-2—M-6
*** Reset C/Bs in order: (001—049) – (151-300)M-6—G-2—M-5—G-1
*** Pull C/Bs in order: (051—149)G-2---M-5
*** Reset C/Bs in order: (051—149)M-5----G-2
***Try Resetting FAP (1st)***Pull for (1) Min in Flight***Note: Decoder / Encoder (Units) (DEU) DEU A = Cabin Lights DEU B = Handsets & Loud Speaker
(1)Or(2)
Min
23 EVAC (Faults) Try Resetting the (Horn) P/B 1stReset CIDS as Above
(2)Min
FOR TRAINING PURPOSE ONLYwww.amevoice.com
- 11 -
23FAP (Frozen)
CIDS Fwd Attd PNl -------M-14 (051-149)
*** Pull C/Bs in order: (All Others)H-1---Q-14
*** Reset C/Bs in order: (All Others)Q-14---H-1
*** If no Help (All)E-1 (2000VU)
10Sec
23 PAX ENT (Faults)(Video & Audio)
Cabin Com Sys (PES) ------F-6 (2000VU)***If no Help (Reset) all DEUs M-7 through M-13***Screens – Reset by Ind (button) (hole)
15Sec
23 TCAS (Faults) TCAS ------------------- K-10 10Sec
23FAP (Frozen)
CIDS Fwd Attd PNl -------M-14 (051-149)
*** Pull C/Bs in order: (All Others)H-1---Q-14
*** Reset C/Bs in order: (All Others)Q-14---H-1
*** If no Help (All)E-1 (2000VU)
10Sec
23 PAX ENT (Faults)(Video & Audio)
Cabin Com Sys (PES) ------F-6 (2000VU)***If no Help (Reset) all DEUs M-7 through M-13***Screens – Reset by Ind (button) (hole)
15Sec
23 TCAS (Faults) TCAS ------------------- K-10 10Sec
FOR TRAINING PURPOSE ONLYwww.amevoice.com
- 12 -
FOR TRAINING PURPOSE ONLYwww.amevoice.com
- 13 -
ATA System or Fault Reset CB / Switch Time
24Battery Charge Limiter
***Reset (1) at a Time with APU Operating Cycle (Affected) Battery Switch
XX
24 Generator Control Unit (GCU) (AOG)
Cycle Generator (Cont) P/B (Affected Gen) XX
24 Ground Power Control Unit (GPCU) (AOG)
*** Engines & APU & Batteries –Off Ground Power -------------------Disconnected XX
24 Eng Gen (on-line)No Ind on ECAM (AOG)
***Engine ---------------------------- Off GCU 1 -----------------------------T-26 GCU 2 -----------------------------T-27
10Sec
24 Ext Power P/B (AOG)(No Green Avail) Light
***Engines & APU & Batteries --Off Ground Power ------------------- Disconnected
30Sec
24 Transformer Rectifier Unit ***Reset (Via) -------------------------CFDS Reset P/B ---------On TRU ------103VU***103VU – Located Above Battery
XX
24 AC ESS BUS (Fault)
Reset ------AC ESS BUSS FEED---P/B***norm pwrd by AC Buss 1 / Buss 2 takes over
XX
24 AC BUSS 1 (Fail) Reset ------AC ESS BUSS FEED---P/B XX
FOR TRAINING PURPOSE ONLYwww.amevoice.com
- 14 -
25Flight Deck Seats (Elect Control)
Captains Seat --------------U-11FO’s Seat -------------------U-14Individual Seat C/B ------ Under Seat
10Sec
FOR TRAINING PURPOSE ONLYwww.amevoice.com
- 15 -
26 Smoke Detector Cont Unit (SDCU)
SDCU Channel 1 -----------------C-6SDCU Channel 2 -----------------T-18***Reset C/B’s Together
(2)Min
26 Fire Detection Unit
(FDU) (AOG)
Eng Fire Loop A & B -------A-6 – Q-38Eng Fire Loop A & B -------A-7 – Q-39APU Fire Loop A & B ------ L-43 – L-44
30Sec
26 Cargo (Detection) (Faults)
Reset (SDCU) as above ***If no HelpAft Cargo Vent & Heat Fan ---S-22Aft Cargo Cont (Mont) ---------C-7
(2)Min
26 Smoke LAV (Msg) Reset (SDCU) as Above XX
FOR TRAINING PURPOSE ONLYwww.amevoice.com
- 16 -
ATA System or Fault Reset CB / Switch Time
27
F/CTL ALT LAWF/CLT ELAC (Fault)F/CTL ELAC PITCH Fault
***Reset ELAC P/B Switch 1st
ELAC 1 (Norm Supply) --------------------B-11ELAC 2 (Norm Supply)---------------------R-20
10Sec
27 SEC (Faults)
*** Reset SEC P/B Switch 1st
SEC 1 (Norm Supply) -----------------------B-8SEC 2 (Norm Supply) -----------------------Q-18SEC 3 (Norm Supply) -----------------------Q-19
10Sec
27 Flt Cont Data Concentrator (FCDC)
FCDC 1 ------------------------B-10FCDC 2 ------------------------Q-20
10Sec
27
Slat / Flap Cont Computer (SFCC) (AOG - Pull All) & Flight Cont (Msgs)
***Engines Running (Pull IAW Chart)Slats (Fault) --------------------B-6 ---R-21Flaps (Fault) -------------------B-7 ---Q-21Slats (Sys 1 Fault) ------------ B-6Slats (Sys 2 Fault) ------------ R-21Flaps (Sys 1 Fault) ----------- B-7Flaps (Sys 2 Fault) ----------- Q-21*** Engines Off (Reset All C/B’s)
(2)Min
27 Side Stick (Priority Msg) Reset FAC & SEC & ELAC P/B Switches (As Above)
XX
27 Flaps Locked Out (Msg) ***Hydraulics ------------------------OffWing Tip Brake Reset (via)--------CFDS
XX
27 Flight Cont (Maint Msg) FCDC 1 --------------------------------B-10FCDC 2 --------------------------------Q-20
10Sec
27 Slow Slats Slat Cont & Mont Sys 1 -------------B-6Slat Cont & Mont Sys 2 -------------R-21
10Sec
FOR TRAINING PURPOSE ONLYwww.amevoice.com
- 17 -
FOR TRAINING PURPOSE ONLYwww.amevoice.com
- 18 -
28 Fuel Quantity Ind Comp (FQIC)
Fuel FQI Channel 1 ----------------A-13Fuel FQI Channel 2 ----------------M-27FQI Channel 1 & 2 -----------------L-26
10Sec
28 APU LP Valve (Fault) Cycle APU Master Switch XX 28 Auto Feed (Fault)
Caused by:Ctr Tnk---above 550lbs with wings B/L 1100lbsCtr Tnk Pp-did not S/O when slats ext (on grd)Ctr Tnk Pp-did not S/O when low level reached
XX
FOR TRAINING PURPOSE ONLYwww.amevoice.com
- 19 -
FOR TRAINING PURPOSE ONLYwww.amevoice.com
- 20 -
ATA System or Fault Reset CB / Switch Time
29 Hyd Res Low Press (Msg) Run Engs or Pressurize Hyd Systen XX
29
PTU Faults
Green / Yellow Sol Valve ------------ N-34***If no Help *** With Engines RunningMaster Caution --------------(Reset P/B)Yellow (Elect) Pump --------(On then Off)Set Parking Brake -----------(Brakes Set)Both Eng Pumps -------------(Off)Yellow (Elect) Pump --------(On)PTU ----------------------------(Off then Auto)Yellow (Elect) Pump --------(Off)Both Eng Pumps -------------(On)
Wait 30SecFor
Each Sw
29Hyd Indication (Faults) & Pump Faults
Brake Pressure (Ind) ------------------C-10Pressure Transmitter ------------------C-11Hyd Power Warn & Cont-------------C-12Eng 1 (Gr) Fire Valve------------------C-13Eng 2 (Yel) Fire Valve-----------------C-14RAT Cont--------------------------------D-14Yellow Hyd Power -------------------- N-30Low Level Ind ------------------ -------N-32Solenoid Valves (G/Y (PTU) --------N-34Solenoid Valves (Leak Test) -------- N-35Quantity Ind ---------(49VU) -------- P-35Yellow (Eng 2) Pump Mont ---------Q-37Yellow (Eng 2) Pump Ctl ------------Q-36Green (Eng 1) Pump Mont ----------R-34Green (Eng 1) Pump Ctl -------------R-35Yellow Elect Pump (Norm)-----------AB-03
10Sec
FOR TRAINING PURPOSE ONLYwww.amevoice.com
- 21 -
Yellow Elect Pump---------------------AB-06Blue Elect Pump (123VU) ------------AB-09
FOR TRAINING PURPOSE ONLYwww.amevoice.com
- 22 -
ATA System or Fault Reset CB / Switch Time
30Window Heat Control Unit
WHC 1 -----------------X-13WHC 2 -----------------W-13***With (Fault on Ground)***Turn Packs (On) and Pull C/B for 5 Minutes***Window Heat (Faults)Window (Left) Heat -------X-14Window (Right) Heat -----W-14
(5)Min
30 Drain Mast Control Unit Fwd Drain Mast-------B-6 or D-1 (2000VU)Aft Drain Mast --------E-1 or D-5 (2001VU)***Can be Reset through FAP (Also)
10Sec
30 Anti Ice (Msg) Anti Ice Probes (PHC 1) -----------D-3Anti Ice Probes (PHC 2) -----------Y-12Anti Ice Probes (PHC 3) -----------Y-16
10Sec
30
Anti Ice (Probes) (Msg) (System 1)
PITOT 1 ------------------D-2STATIC 1 ----------------Z-13AOA 1 -------------------- D-4TAT 1 ---------------------Z-12***If no Help (Reset)ADIRU 1 –(26vac)--------F-7 & AOA 1 ----D-4ADIRU 1 –(115vac)------T-6
10Sec
30Anti Ice (Probes) (Msg) (System 2)
PITOT 2 ------------------Y-14STATIC 2 ----------------Y-11AOA 2 -------------------- Y-13TAT 2 ---------------------Y-15***If no Help (Reset)ADIRU 2 –(26vac) ------N-9 & AOA 2 -----Y-13ADIRU 2 – (115vac) ----N-7ADIRU 2 – (28vdc) -----N-5ADIRU – (Pwr Shed) ---N-11
10Sec
30Anti Ice (Probes) (Msg) (System 3)
PITOT 3 ------------------Z-16 (Stby)STATIC 3 ----------------Z-14 (Stby)AOA 3 -------------------- Z-15 (Stby)***If no Help (Reset)ADIRU 3 –(26vac) ------N-8 & AOA 2 -----Z-15ADIRU 3 – (115vac) ----N-6ADIRU 3 – (28vdc) -----N-4ADIRU 3 – Switching Supply – N-10
10Sec
FOR TRAINING PURPOSE ONLYwww.amevoice.com
- 23 -
FOR TRAINING PURPOSE ONLYwww.amevoice.com
- 24 -
ATA System or Fault Reset CB / Switch Time
31
Flight Warning Computer
FWS – FWC Fault (AOG)
***Only Reset (1) at a time in FlightFWC 1 --------------------------F-1FWC 2 ------------------------- Q-7***Reset (both) at the same time on the ground
30Sec
31 Cent Fault Data Inter Unit (CFDIU) (AOG)
CFDS / DFSIU / Supply --------J-18CFDS / CFDIU / Back Up -----J-17
10Sec
31 Flight Data Inter Unit (FDIU) (AOG)
***Engines --------------------OffRecorder FDIU & QAR -----K-17
10Sec
31 Display Mgmt Computer (DMC) (AOG)
EIS DMC 1 --------------------E-9 ----E-11EIS DMC 2 --------------------Q-8 ----R-8EIS DMC 3 --------------------E-7 ----E-10 ---Q-9
30Sec
31 Display Mgmt Unit (DMU) (AOG)
Capt PFD ----------------------E-3 ----E-4Capt ND ----------------------- E-1 -----E-2FO’s PFD ----------------------R-3 ----R-5FO’s ND ----------------------- R-4 -----R-6Upper ECAM ---------------- E-5 ------D-6Lower ECAM ---------------- R-10 ----R-11
(2)Min
31 System Data Aciq Unit (SDAC) (AOG)
***Reset all (7) C/B’s TogetherSDAC 1 ------------------------------ F-2 ---F-4 SDAC 1 & 2 ------------------------ F-5EIS SDAC 1 -------------------------Q-3 –-Q-4EIS SDAC 1 & 2 --------------------P-3 ---P-4
SDAC 2 -------------------------------F-3SDAC 1 & 2 ------------------------- F-5EIS SDAC 2 -----------------Q-2 ---Q-5 ---Q-6EIS SDAC 1 & 2 --------------------P-3 ---P-4***Additional C/B’s for Door IndSDAC 1 & 2 –Door Avionics / PAX –P-2---P-5
(2)Min
31 ECAM (Pages) Locked Reset FWC’s as Above XX
31
AIDS Indication (MCDU) & Printer Not Allowed
Recorder FDIU / QAR -------------K-17Printer Supply -----------------------J-21
10Sec
31 DAR / QAR (Msg)
***Check if Media is FullRecorder FDIU / QAR ----------- K-17ACCLRM ---------------------------K-18
10Sec
31 Digital Flt Data Recorder (DFDR)
Recorder / DFDR ------------------K-16 10Sec
31 Invalid Data on the (DCDU)Or MCDU (ATC) Page
ATSU 1 -----------------------------L-16ATSU 1 SWTG -------------------L-15
10Sec
ATA System or Fault Reset CB / Switch Time31 Clock (Off from ECAM) Clock Norm Supply----------------------F-11 10
FOR TRAINING PURPOSE ONLYwww.amevoice.com
- 25 -
Clock Stand By Supply------------------N-2***Some AC (Stby Supply-------------N-3
Sec
FOR TRAINING PURPOSE ONLYwww.amevoice.com
- 26 -
FOR TRAINING PURPOSE ONLYwww.amevoice.com
- 27 -
ATA System or Fault Reset CB / Switch Time 32
Landing Gear Cont Unit L/G LFCIU Fault
***Only Reset (1) at a time in Flight
***Open in Order:LGCIU 1------Q-34----C-9***Close in Order:LGCIU---------C-9----Q-34
LGCIU 2 –(Open—Q-35) -----(Close----Q-35)
30Sec
32 Brake Steering Cont Unit
(BSCU)
***In-Flight (Do not Reset any C/B’s***Try Cycling AS/NWS Switch 1st (10 Sec) (Note: Switch (swaps) Channels)***On-GroundAS/NWS (Switch) ---------------------OffHyd Brake & Steering Sys -----M-33 thru M-36AS/NWS (Switch) ---------------------On
(1)Min
32 Brake Temp (Indication) Brake Temp Det Unit ----------------M-37 10Sec
32 Brake Fan (Faults) Brake Fan Cont -----------------------M-32Fan (Wheels) 1 & 2 -------------------L-32Fan (Wheels) 3 & 4 -------------------L-35
10Sec
32 Tire Pressure (Indication) Tire Pressure Indication ------------M-31 10Sec
FOR TRAINING PURPOSE ONLYwww.amevoice.com
- 28 -
FOR TRAINING PURPOSE ONLYwww.amevoice.com
- 29 -
FOR TRAINING PURPOSE ONLYwww.amevoice.com
- 30 -
ATA System or Fault Reset CB / Switch Time
33 Wheel Well (Lights) AndAPU (Service) Lights
Lights Sec 19 --------------------F-5 (2001VU)APU SVC Light ----------------F-6 (2001VU)
10Sec
33 Cabin Light (Faults) AndFlt Attn Light (Faults)
*** Reset CIDS (via) FAP or MCDU***If no Help –Reset ----------Q-14***If no Help –Reset CIDS (Ref Ch 23)***Note: Decoder / Encoder (Units) (DEU) DEU A = Cabin Lights DEU B = Attend Lights / Signs
10Sec
ATA System or Fault Reset CB / Switch Time
34 ADIRU (Faults)
(AOG) (Stand-By Instruments)
***Quick Align (ADIRU to Off then to NAV) (Wait 15 Seconds) (Try 1st)***Only Reset C/B’s on Ground***If no Help –Reset SystemADIRU 1 --------------------C-2---F-6---F-7ADIRU 2 ----------------N-4 ---N-6---N-8---N-10ADIRU 3 -------------F-9---N-3---N-5---N-7---N-9Stand-By (Inst) -----F-12---F-13---J-1
15Sec
34 GPWS GPWS ---------------------P-6-------P-7 15Sec
34 Baro Reference (Fault) ***Reset FCU’s (Ref Ch 22) XX 34 Wind Shear (Faults) Reset FAC’s –Ref Ch 22 XX
34Navigation (Sys) (Faults)
ADF -------#1-H-14----------#2-K-2ATC -------#1-G-11----------#2-K-7DME ------#1-G-14-----------#2-K-6ILS ---------#1-G-12----------#2-K-9RADAR ---#1-K-13----------#2-K-14
10Sec
FOR TRAINING PURPOSE ONLYwww.amevoice.com
- 31 -
RA ----------#1-K-11---------#2-K-12VOR --------#1-G-13---------#2-K-8
34 TCAS (Faults) TCAS ------------------- K-10 10Sec
FOR TRAINING PURPOSE ONLYwww.amevoice.com
- 32 -
FOR TRAINING PURPOSE ONLYwww.amevoice.com
- 33 -
ATA System or Fault Reset CB / Switch Time
36 Bleed Mgmt Comp (BMC)
Air Bleed Eng 1 ---------------- D-11----D-12Air Bleed Eng 2 ---------------- Z-22----Z-23
(1)Min
36 Bleed (Leak) Msgs ***Reset (affected) Bleed Switch 1st
***If no Help ----------Reset BMC as AboveXX
36 Cross Bleed (Faults)
***Reset BMC as Above***If no Help Reset Listed SDAC C/B’sSDAC 1 Supply -----F-4SDAC 2 Supply -----Q-6
10Sec
36 Cross Bleed Valve (Msg) Air Bleed Cross Feed Valve (Bat) -----D-13Air Bleed Cross Feed Valve (Norm)—Z-20
10Sec
FOR TRAINING PURPOSE ONLYwww.amevoice.com
- 34 -
Position) and (p/b Switch) Position------------------------------------------------------------------------------------------------------------AIR APU BLEED LEAK Engine Running------APU Bleed Valve Controlled to (Open)------------------------------------------------------------------------------------------------------------AIR BLEED ABNORMAL PR: (With Msg) Press Reg V 4001HA or Sol 10HA or Sense Eng Bleed Opening (Disagree) Eng Reg Press is Below the Operating Press of the PRV –(Low Press Det) Regulated Pressure is lower than (23 PSI) HP Valve (indication) is Amber Change the: PRV / Check the Sense Line / R&R the Bleed Pr Reg Ctl Sol 10HAAIR ENG BLEED FAULT (With Msg (FAV 9HA or Thrm 7170HM or Sense Line O/T (Condition) Change the (FAV -T-Stat) / Check the Sense Line (FAV) / Change the FAV / R&R the Exchanger Outlet Temp (Sensor) 6HA / WiringAIR ENG BLEED (LO TEMP): (With F/M Fan Air V 9HA or THRM 7170HM) Low Temp (Reg) (Detection) Eng Bleed Air Temperature Drops Below 150 deg C In Flight (Anti Ice) (ON) -- Change the FAV (T-Stat) / FAVAIR ENG BLEED FAULT (With Failure Message Press Reg V 4001HA) Over Pressure (Condition)-----PRV and HP (Valves) Close Automatically Change the PRV - or - Bleed Regulated Pressure Transducer (8HA)AIR ENGINE BLEED LEAK Pylon Leak-------PRV and HP (Valves) close AutomaticallyAIR ENG BLEED NOT CLOSED (With F/M Press Reg V 4001HA or Sol 10HA Eng PRV Valve (Did Not) Auto Close when the (APU Bleed) Valve was (Open) Engine Bleed Closure (Disagree) R&R the PRV – Check the Sense Line (PRV/HP) / Bleed Press Reg Sol 10HA
FOR TRAINING PURPOSE ONLYwww.amevoice.com
- 35 -
------------------------------------------------------------------------------------------------------------AIR WING LEAK Both or (one)--- (Detection) Loops Failed------------------------------------------------------------------------------------------------------------BLEED MONT FAULT-------Both BMCs Failed------------------------------------------------------------------------------------------------------------CROSS BLEED FAULT: Eng and APU are Running (Together)------APU Bleed Air is selected (ON)------------------------------------------------------------------------------------------------------------ENG HP VALVE FAULT (With F/M HP Bleed 4000HA or Sense Line) HP Valve (Closed with Eng @ Idle) (Opening Disagree) Change the HPV / Check the Sense Line / Wiring
ATA System or Fault Reset CB / Switch Time
38 Water Quantity Ind Water System ---------------D-3---(2000VU) 10Sec
38 Coffee Maker (Noise) (Leak) Place Finger over Drain Tube 10Sec
38 Toilette Wont FlushToilette System ------------35MG –(2001VU)***If no Help (via) (2001VU)VAC Tol Sys Lav Pwr ----B-1---B-3---B-4
15Sec
ATA System or Fault Reset CB / Switch Time
49 APU Bleed (Faults) ***APU -----------------OffECB Supply------------L-41APU Cont --------------L-42
10Sec
49 APU (Will Not Shut Down) Pull C/B’s --------------L-42-----L-41 XX 49 APU (No Volts or Freqs) ***APU ---Off----On
***If no HelpAPU GCU ---------Y-25
10Sec
FOR TRAINING PURPOSE ONLYwww.amevoice.com
- 36 -
ATA System or Fault Reset CB / Switch Time
73 Engine (FADEC) Fault (AOG) Engine (IGN) Fault
***Try Resetting FADEC P/B 1st***Engines --------------------Off***Wait (5) Minutes then Pull C/B’sENG 1 FADEC A & EIU 1 -------A-4ENG 1 FADEC B -------------------R-41ENG 2 FADEC A & EIU 2 -------A-5ENG 2 FADEC B -------------------Q-40
10Sec
73 EPR Mode (Fault) Cycle Engine (N1) Mode Switch XX 73
Engine Integration Unit (EIU)
Try Oil Pressure C/B 1st -------N-40 ---N-42***If no HelpPerform CFDS (Test) FADEC 1 & 2***If no HelpEng Start (Switch) ---(Norm to Crank) (15 Sec)Return to (Norm) – (Wait 5 Minutes)-(Repeat)
15Sec
FOR TRAINING PURPOSE ONLYwww.amevoice.com
- 37 -
FOR TRAINING PURPOSE ONLYwww.amevoice.com
- 38 -
Bleed Press Ind: Amb when the Bld Press is below 21 PSI and The (srt vlv) not open------------------------------------------------------------------------------------------------------------EGT OVER LIMIT : is shown when a. EGT is more than 610 Deg C (Flashes Amber) b. EGT is more than 635 Deg C (Flashes RED) c. N1 greater than 100% – Flashes (RED) d. N2 greater than 100% - (Steady RED)------------------------------------------------------------------------------------------------------------EPR MODE FAULT – (A) – Engine in N1 Mode (EPR) Lost------------------------------------------------------------------------------------------------------------FADEC FAULT (A) – Both EEC channels are (faulty)------------------------------------------------------------------------------------------------------------FUEL FILTER CLOG – (A) – Fuel Filter (clogged)------------------------------------------------------------------------------------------------------------FUEL VALVE FLT – (A) – (PRSOV) fails opn or closed Or Fuel Vlv (not open)
FOR TRAINING PURPOSE ONLYwww.amevoice.com
- 39 -
------------------------------------------------------------------------------------------------------------OIL FILTER CLOG – (A) – Scavenge oil filter (clogged)OIL HI TEMP – (A) – Oil Temp between (156 & 165 Degrees C)------------------------------------------------------------------------------------------------------------OIL LO PRESSURE – (R) – Pressure lower than 60 PSI------------------------------------------------------------------------------------------------------------OIL LO TEMP – (A) – Oil Temp below (-10 Deg C) or (-50 Deg C @ TO)------------------------------------------------------------------------------------------------------------TLA LEVER DISAGREE – (A) – Disagreement between revolvers and thrust levers ------------------------------------------------------------------------------------------------------------THR LEVER FAULT – (A) – Both Revolvers or Thrust Lever (failed)Note: There are (2) revolvers per throttle lever------------------------------------------------------------------------------------------------------------
FOR TRAINING PURPOSE ONLYwww.amevoice.com
- 40 -
21) Air Conditioning
AIV---Prevents ice b/u D/S of the ACM turbine, Cont’s pack discharge temp In case of failure (via) the pack outlet Pnue Sensor------------------------------------------------------------------------------------------------------------ By Pass Valve---Cont’s ACM by pass for pack outlet modulation------------------------------------------------------------------------------------------------------------ Bleed Temp Sensor---Provides supplementary info to pack & zone cont------------------------------------------------------------------------------------------------------------ Comp Temp Snsr---Provides Comp O/L temp to (PC) pri chan for O/H det------------------------------------------------------------------------------------------------------------ Comp O/H Snsr---Prov comp O/L Temp to (PC) Sec chan for O/H det & ECAM------------------------------------------------------------------------------------------------------------ Condenser---cools airflow in wtr extraction loop below its dew point------------------------------------------------------------------------------------------------------------ Comp Pneu O/H Snsr---protects against pack O/H by grad closing FCV When comp discharge temp ^ 230 C------------------------------------------------------------------------------------------------------------ Flow Amp---provides elect signal to (PC) –relating to flow thru the FCV------------------------------------------------------------------------------------------------------------ FCV—cont’s the flow of bleed air entering the pack and trim air system------------------------------------------------------------------------------------------------------------ Main Heat Exch---uses ram air to cool air leaving the ACM comp------------------------------------------------------------------------------------------------------------ Pack O/L Temp Snsr---prov pack O/L temp info to (PC) for ECAM & O/H det------------------------------------------------------------------------------------------------------------ Pri Heat Exc---uses ram air to cool the air ent the (ACM) compressor------------------------------------------------------------------------------------------------------------ Pack I/L Press Snsr—ind increased ACM bypass under low bleed press cond inflt------------------------------------------------------------------------------------------------------------ Plenum Chamber---ensures ACM fan airflow thru ram air circuit on ground------------------------------------------------------------------------------------------------------------ Pack O/L Pnue Snsr---modulates AIV to cont pack O/L temp in case of failure------------------------------------------------------------------------------------------------------------ Water Ext Temp Snsr---Provides info for pack temp modulation------------------------------------------------------------------------------------------------------------ Ram Air I/L & O/L Act---reg ram air flow for minimal drag------------------------------------------------------------------------------------------------------------ Reheater---optim ACM turb effic , stops press of water at turb I/L------------------------------------------------------------------------------------------------------------ Water Ext---removes moist from the air leaving the condenser by (Cent Force)------------------------------------------------------------------------------------------------------------ Water Inj---increases the cooling effic of the heat exchanger------------------------------------------------------------------------------------------------------------ Zone Cont---ensures cabin temp cont and mont , estab pack O/L temp demand
FOR TRAINING PURPOSE ONLYwww.amevoice.com
- 41 -
Engine BLEED AIR is sent to the OZONE FILTERS – (then) to PKFLOW CONTROL VALVE – (then) PART of the AIR is sent through the HOT AIR PRESSURE REGULATING VALVE (which regulates the pressure to the TRIM AIR VALVE and (then) the REST of the AIR is sent to the PRIMARY HEAT EXCANGER (to cool the air) and (then) it is sent to the Compressor Section of the ACM (where the air is compressed to a higher pressure , which also raises the temperature) and (then) the air is sent to the MAIN HEAT EXCANGER (where the air is cooled again) and (then) the air is sent to the WATER SEPERATOR (where the moisture from the air is removed) and (then) the air is sent to the Turbine Section of the ACM (where the air expands to generate the power to drive the (ACM) this removal of energy from the air lowers the temperature of the air) and (then) the air is sent to the MIXER UNIT (where it is mixed with the re-circulated fan air) and (then) the mixed air is sent to the TRIM AIR VALVES and (then) to the SUPPLY DUCTS.
FOR TRAINING PURPOSE ONLYwww.amevoice.com
- 42 -
FOR TRAINING PURPOSE ONLYwww.amevoice.com
- 43 -
FOR TRAINING PURPOSE ONLYwww.amevoice.com
- 44 -
FOR TRAINING PURPOSE ONLYwww.amevoice.com
- 45 -
FOR TRAINING PURPOSE ONLYwww.amevoice.com
- 46 -
FOR TRAINING PURPOSE ONLYwww.amevoice.com
- 47 -
FOR TRAINING PURPOSE ONLYwww.amevoice.com
- 48 -
FOR TRAINING PURPOSE ONLYwww.amevoice.com
- 49 -
29) HydraulicsReservoir Low Pressure Switch – located on the reservoir by the (head press) gauge.Normal Head Pressure = 50 PSI and it sends a ECAM message Reservoir Low PresAt 30 PSI. (only during phases 8,9 and 10)Note: The Press Switch (Closes) at 30 PSI (ECAM indication) and (Opens) at 33 PSINote: The Blue System reservoir has (2) pressure switches (1) as listed above and(1) for ECAM indication at 22 PSI (only during phases 5,6 and 7) it also provides a CLASS II – Maint Status message via the SDAC
Note: The Switch (Closes) at 22 PSI and (Opens) at 25 PSI Note: This Warning will not automatically cancel-----------------------------------------------------------------------------------------------------------Hyd Press Switch (Hyd Pump)– 3ea- monitors O/P press of the pump.
Sends signals to the ECAM when the press is at 1740 PSI (yell & Grn) And 1450 for the Blue Elect Pump) Normal Pressure of the pump = 1750 to 2250 PSI Located L/H side of engine (just above the case drain filter) (for Engines) And Down Stream of the (Blue Electric Pump) Fin # : 1074GK (green) 2074GJ (blue) 3074GD (yellow) -----------------------------------------------------------------------------------------------------------Hyd Press Sw – located on the HP manifold – sends the (low) and (hi) pres
Signals to the SDAC for display on the ECAM a. Switch: # 1151GN (green) 2151GN (blue) 3151GN (yellow) Sends info to the FWC, (ELACS and SECS) (FAC) Sw (Closes) and sends a (Lo Press) warn at 1450 psi and (Opens) at 1750 PSI Note: At 1750 PSI the warning is automatically canceled Note: Switch # 1151GN also sends info to the brake system Switch: # 10CE1 (gr)-----10CE2 (bl)----10CE3 (yell)------------------------------------------------------------------------------------------------------------Hyd Press Transducer (trans) – sends info to the SDAC Ecam Ind (HP manifold)
FOR TRAINING PURPOSE ONLYwww.amevoice.com
- 50 -
Note: at 1450 PSI the (indication) changes to amber Note: These only send the (digital) indication to the ECAM FIN # : 1065GN (gr) 2065GN (bl) 3065GN (yell) 3068GN (brk press –yell)------------------------------------------------------------------------------------------------------------Pressure Relief Val – protects sys from O/P. opens at 3426 PSI and Closes at 3190
33) LightsIntegral Light Controllers:
6LF – above Flight Deck Door – Controls O/H Panel (Integral Lights) 16LF – Fwd. Elect Bay (Upper) – Controls Main Inst Panel (Integral Lights) 30LF – Fwd Elect Bay (Upper) – Controls Glare Shield Integral Lights)---------------------------------------------------------------------------------------------------Annunciator Light Transformers - located above Flight Deck Door
31LP – Powered from AC ESS (Network) 35LP – Powered from AC ESS (Network) 36LP – Powered from AC NORMAL (Network) 37LP – Powered from AC NORMAL (Network)
FOR TRAINING PURPOSE ONLYwww.amevoice.com
- 51 -
36) Pneumatics
Engine Bleed Air System: (Normal Operation)
Engine Bleed Air is taken from the 7th Stage and 10th Stage Compressor
It is sent to the (IP) Check Valve: (To prevent backflow) (back into)--(Then-If) (IP) 7th Stage Comp (Closes when (HP) air is being used) The (Air Press) is 37 PSI or More (7th Stg (IP) Air is Used and--(Air Sent to PRV)
The (Air Press) is 36 PSI or Less (10th Stg (HP) Air Is Used and---(And) (The) The (HP) Valve (Opens) to allow (10th Stage HP) Air to be Used ---- (Then) Note: Valve Spring Loaded (Closed) (Pneumatically Operated) And is (Connected) to the (PRV) via a (Sense Line) and (Elect) To a (Control Solenoid) Either the (IP) or (HP) Air is used (Depending On PSI) (Then)
The (Air) is sent to the Pressure Regulating Valve (PRV) (Then) Note: Regulates Pressure to 44 PSI (Downstream)
FOR TRAINING PURPOSE ONLYwww.amevoice.com
- 52 -
Note: Pneumatically (Operated) and Electrically (Controlled) By the (PRV) (Control Valve Solenoid) (Which) Is installed in the (Duct) (Downstream) of the (Pre-Cooler) When the (Solenoid) Energizes it (Opens) the (HP/PRV) Sense Line (Which Vents) the (Sense Line) Air into the (Fan Air) The (PRV) and (HP) Valve (Close) (via spring loaded) Allowing (IP) Air to be used
The (Air) is sent to the Overpressure Valve (OPV) (Then) Note: Protects System from overpressure (D/S)-(Spr Lod open)
The (Air) is sent to the (Engine Start Valve) (Then) (If Needed the PRV & HP Valves Close) (If Not Air is sent to the PC) The (Air) is sent to the Pre-Cooler (Then) Note: The (Air) is (Cooled) to 200 deg C / 392 deg F (Via) By-Pass (Fan Air) blowing across the Pre Cooler (and is controlled by) The Fan Air Valve (FAV) and FAV (Control T-Stat) (Which) Controls the (ops) of the FAV by telling it to (Open) When the (temp) (D/S) of the Pre Cooler is Above (200 deg C / 392 deg F) Note: The FAV is Spring Loaded (Closed)
The (Cooled Air) is sent to the Cross Bleed Valve (To Be Used for A/C Sys)
FOR TRAINING PURPOSE ONLYwww.amevoice.com
- 53 -
Cont Temp Snsr– Sends Temp Info (from the Pre Cooler) outlet duct to (BMCs) (for mont) – and then the BMCs send the Temp info to the (SDACs) for ECAM Ind.-----------------------------------------------------------------------------------------------------------Fan Air Cont ( Temp Ctl T-Stat) – (TCT) Connected to the FAV. It commands theFAV to (OPEN) if the (Temp) D/S of the Pre-Cooler exceeds 200 deg C.(Located in pylon- aft of the pre cool) (Next to the Bleed Press Cont Sol)
-----------------------------------------------------------------------------------------------------------Transferred Pressure Transducer – HP VALVE FAULT (Warn)
7 HA1 - 7HA2 AIR ENG ABNPRESSURE (Warn) Note: Will not affect (Bleed Pressure Indication)
Measures Transfer Pressure (between the (PRV) and (HP) ValvesSense Line (connects) to the Duct downstream of the (HP Valve)Info is sent to the BMCs and then is sent to the CFDIU and SDACs (Ecam)
Message is Gen (IF) the transferred press is less than (23 PSI) for more Than 15 Seconds and the (HP) Valve is closed------------------------------------------------------------------------------------------------------------ Regulated Pressure Transducer – AIR ENG BLEED (Fault) 8HA1 – 8HA2 AIR ENG ABNORMAL PRESSURE (Warn) WING ANTI- ICE INOP (Status Message) Used for Pressure Indication to the (ECAM) Sense Line (connects) to the Duct downstream of the (PRV) Air Eng Bleed – is activated (When) – The Reg Press is higher than 57 PSI For more than 15 seconds. And the (PRV) is (Not) Closed. Air Eng Abnormal Press – is activated (When) – The (Reg Press) is Lower Than 23 PSI (AND) the (Transferred Press) is (Between) (12 to 38 PSI) Wing Anti Ice Inop - is activated when – (Act by the (Zone Cont) via Info (Rec) from the BMCs. When the (Reg Pres) is out of (Norm) Range which is (12 to 60 PSI) ----------------------------------------------------------------------------------------------------------
Bleed Press Ctl Sol: Limits (Press & Temp) D/S the Pre Cooler. It Conts the (PRV) Monitored by the BMC and Controlled by the EEC When Tp Reaches (d/s of the PRV) 235 deg C (PRV) closes slightly (Lowers Press) When Tp Reaches (d/s of the PRV) 245 deg C – Bleed Pres is Lim to 17.5 PSI------------------------------------------------------------------------------------------------------------ When any of the following occur: the (PRV) Automatically Closes O/T (D/S of the Pre-Cooler) @ 257 +- 3 deg C (60 sec delay) O/P (Downstream of the PRV 57 +_ 3 PSI (15 sec delay) O/H in the Bleed Ducting of the Pylon, Wing, Fuselage APU Bleed Valve (Not Closed) or Start Valve (Not Closed) Engine Bleed (p/b Switch) & Engine Fire (p/b switch) (selected out) Thermal Fuse (In Valve Body) Closes Valve @ 450 +- 25 deg C------------------------------------------------------------------------------------------------------------Bleed Press Ind: Norm = 35 PSI / Amb = Lwr than 4 & Over 57 PSI------------------------------------------------------------------------------------------------------------Bleed Temp Ind: (O/H) 290 deg C more than (5 seconds) or
270 deg C more than (15 seconds) or 257 deg C more than (55 seconds)
FOR TRAINING PURPOSE ONLYwww.amevoice.com
- 54 -
FOR TRAINING PURPOSE ONLYwww.amevoice.com
- 55 -
FOR TRAINING PURPOSE ONLYwww.amevoice.com
- 56 -
38) Water WasteLiquid Level (SENSOR) – Mounted on top of the Waste Tank – Sends signal to the
Vacuum System Controller – (When the Waste Tank is (FULL)
Liquid Level (TRANSMITTER) – Mounted on the Bottom of the Waste Tank Sends Signal to the VSC – (WEIGHT of the WASTE) In the Waste Tank.
FOR TRAINING PURPOSE ONLYwww.amevoice.com
- 57 -
Note: Sys Inop (Indication) on the FAP – Check the Vac Gen relay , Vac Gen Or (Lav Door Switch)
49) APU(Garrett GTCP 36300)
1. Normal Start – Sequence of Events
A. Master P/B Switch – (ON) B. Main Relay (Energized) ------- (107VU Panel) – (relay panel above battery) C. ECB starts Power Up (Test) D. APU Fuel Pump – (Energized) E. APU (Inlet Door) – (Opens)
2. Start P/B Switch – (ON) A. (ON) Light in the P/B Switch comes (ON) B. The (ECB) (Energizes) the (Back Up Start Contactor 10KA) -- (Behind 120VU) C. After (1.5 seconds) the (Start Contactor) is (Energized) 5KA -- (Behind 120VU) !!!!!!!! (If these conditions are met) (Line C only) 1. The Air Intake is: (OPEN) --------------------- (Flap Open Indication) 2. The (ECB) Power Up Test is: (Complete) 3. The (N) Speed is (Less than 7%) 4. (AN) Automatic Shutdown is: (Not Detected) – (Via the ECB) 5. (A) Commanded S/D is: (Not Detected) – (Via the Master Switch to Off) 6. The (Data) Exc bwn the DDM and ECB is: (Comp) – (Approx 15 Seconds)
3. Both (Cntrs) Energize the Starter – (Turns) & (Clutch Engages) & (APU Spools)
4. Both (Contactors) Energize the (Igniter)
5. The (De-Oil Valve)-(Opens)-(IF) A. Oil Temp (Below 20 deg F / 6.6 Deg C) B. Fuel Temp (Below 10 deg F / (-12 deg C) C. Altitude (Above) 20,000 Feet6. The APU (Operational) Data (Shown on the ECAM)
FOR TRAINING PURPOSE ONLYwww.amevoice.com
- 58 -
7. At 7% (N) Speed the (ECB) A. Opens the (Fuel Solenoid Valve) – (In the FCU) B. Controls the (Fuel Flow) to the APU with (start acceleration control – logic) C. The IGVs - (Close) to (0 Degrees)
8. At 50% (N) Speed the (ECB) (if above 20,000 feet altitude 58%) A. (De-Energizes) the (Start Contactor) 5KA B. Starter (Dis-Engages) C. APU – (Accelerates) ------------- (N) Speed and EGT Rise D. The IGVs (Open) to the (Fully Closed position of 15 degrees) (50% to 95%) D. (De-Energies) the (Back-Up Start Contactor) 10KA ---- (after 5 seconds)
9. At 60% (N) Speed the (ECB) A. (De-Energizes) the (Ignition Unit) B. (De-Energizes) the (De-Oil Solenoid) ------- (If Open) C. IGVs still @ 15 Degrees (Fully Closed Position)
10. At 95% (N) Speed the (ECB) A. Controls and Monitors the APU (Automatically) B. The IGVs – (Open) to 22 Degrees C. The (Green) Available Light in the (Start P/B) – (Comes ON) D. The (Blue) (ON) light in the (Start P/B) – (Goes OFF)
11. APU (Bleed & Generator) are ready for operation A. APU Bleed and Generator (ON)
12. When you shutdown the APU, the ECB reacts as if it were an Auto Shutdown
13. Operating Notes: A. Max EGT = 635 C / 1175 deg F B. Fuel Inlet Pressure = Min 5 PSI - Max 55 PSI C. Fuel Inlet Temperature = (- 40 deg C to 57 deg C) or (-40 deg F to 135 deg F) D. Oil Tank = 1.65 Gallons E. IGV Actuator = (non operating) – Closed F. Surge Control Valve = (non operating) – Open G. Bleed Load Valve = (Normal) - Closed
Note: (N) = Nominal Speed
Note: (DDM) = Data Memory Module
Note: While the (RAT) is being extended – APU Starting is (Inhibited) by the Battery Charging Limiters (BCLs)
FOR TRAINING PURPOSE ONLYwww.amevoice.com
- 59 -
Which prevents the (Start Contactor) from being energized (for 45 seconds)
P2 – Sensor – R/H side inlet duct – Provides Input signal to the ECB , to Modify the schedules of the Surge Valve and FCU------------------------------------------------------------------------------------------------------------Load Comp I/L Temp Snsr – Located Below the IGV Actuator – Input Signal to theECB , which is used in the reverse flow protection logic.------------------------------------------------------------------------------------------------------------Inlet Guide Vanes: Cont by the ECB – Which Drives the Act--Cont Bleed Air Flow a. Uses Fuel Pressure to (Drive them open and closed) b. Remain (Closed) when APU is (Below 50%) - (Ign on between 7% and 50%) c. 10 Degrees (Open) (Between 50% and 75%) (N) - (starter disengages @ 50%) d. Minimum (Open Position) for the APU to Start = 22 Degrees e. Maximum (Open Position) While the APU is Running = 88 Degrees open f. After APU is Started = 88 Degrees (Open) g. While the APU is Running (They Open & Close) (Depending on Load) h. Generator Load = Close - (To Give priority to Electric Power) i. Drive Load = Open - (To Give priority to Pneumatic Air)------------------------------------------------------------------------------------------------------------Load Bleed Valve – Allows Bleed Air to the A/C Systems – Cont by the APU Bleedp/b Switch. (Note: When the Cross Bleed Valve is in Auto) it will also move to the position of the Load Bleed Valve.------------------------------------------------------------------------------------------------------------Surge Control Valve – Dumps excess bleed air (that is not needed from the APU)Into the Exh Air – Located in the (T-Duct) R/H side of the APU (Ctld by the ECB)------------------------------------------------------------------------------------------------------------
EnginesEngine Sensors and Switches
FOR TRAINING PURPOSE ONLYwww.amevoice.com
- 60 -
a. N1 – Provides N1 rotation speed ind to ECAM--- (2 O’clock) (R/H Fan) b. N2 – Provides N2 rotation speed ind to ECAM--- (dedicated alternator) c. Nacelle Temperature Sensor –Nacelle Temp (6 O’clock) (Core) d. Eng Bleed Pressure – (Ref: Engines) e. Fuel Temp Sensor - fuel temp in the FCOC---(FCOC outlet) f. Fuel Press Diff Sw – fuel press at FCOC O/L---( scav filt 8 clock) g. Fuel Flow Trans – provides fuel flow ind---(under the FMU) 7 -clock h. p2/t2 Sensor - measures I/L press / temp---(Nose cowl) (12 O’clock) i. p5 sensor – measures ex press---(Exhaust Struts) j. p3/t3 – measures press / temp at HP (sends data to EEC)-(HP Comp (outlet) k. p5 (4.9) – measures exh press (located on exh struts) l. p2.5 sensor & t2.5 –provides air pressure from the L/P comp exit to AIDS m. p12.5 sensor – provides air pressure from fan exit to AIDS
Note: p2 & p5 – Used to Calculate EPR
EEC – Provides Automatic Engine starting Powered by a (ded alt) – when N2 is 10% or Higher / A/C Power if (not) Has (2) Channels – (1) active and (1) stand-by – (swaps @ eng shutdown) Receives (info) data from the EIU for engine management
Sends Primary engine (data) to the ECAM (Via) the EEC 1. EPR 2. N1 (via the N1 sensor) (2 O’clock – R Fan) 3. N2 (via the dedicated alt) - 4. EGT 5. Fuel Flow (via the fuel flow meter)
Sends Secondary engine (data) to the ECAM (via) the EIU 1. Fuel Used 2. Oil Temperature 3. Oil Qty (via the Oil Level Trans) – (oil tank) – (7 O’clock – L Fan) 4. Oil Pressure (via the oil pressure transmitter (9 O’clock L Fan) Note: Oil Press Sw – provides warn on ECAM –press below 60 PSI 5. Nacelle Temp (via the Nacelle Temp sensor) - (6 O’clock – Core) 6. Vibration Monitoring
Channel (A) is Fwd and Channel (B) is Aft. Connections are: 1. Pamb – Ambient Air pressure (from fan case sensor)
FOR TRAINING PURPOSE ONLYwww.amevoice.com
- 61 -
2. Pb – Burner pressure 3. P2 – Fan Inlet pressure (from the P2 / T2 Sensor) (10 O’clock – Inlet) 4. P 2.5 – Booster Stage outlet pressure – 5. P 12.5 – Fan Outlet pressure 6. P 25 / 4.9 – LP Turbine exhaust (from the pressure rakes) Electrical Connections – (J -1 to J-11)------------------------------------------------------------------------------------------------------------Variable Stator Vane Actuator (VSVA) – located 4 O’clock position L/H Fan a. Directs the Airflow into the H/P comp to prevent blade stall and engine surge. b. Drives the variable stator vanes (via) fuel pressure c. Controlled (via) the EEC from the feedback signals from the VSV act position----------------------------------------------------------------------------------------------------------Booster Stg Bleed Valve (BSBV) (2.5) – (mstr L/H / Slave R/H) (3 and 9 O’clock) a. Permits booster compressor (airflow) discharge into the (Fan) air stream b. Ensures that the (Booster Compressor) outlet matches the (HP Compressor) Requirements @ (Low Engine Speeds and Deceleration)
FOR TRAINING PURPOSE ONLYwww.amevoice.com
- 62 -
Flight Deck (switches) A. FADEC – Grd Power – Provides power to the EEC for (on-ground) tests B. Thrust Bump – (on fwd end of thrust levers) 1. used to obtain (additional) thrust @ take-off (10% Thrust Boost) 2. used for TOGA – (engages on grd when eng running & p/b is pressed. Disengages when the p/b is pressed or eng is shut down. C. N1 Mode (p/b switch) – man selects N1 mode in case of (loss of EPR ind) D. Mode select switch – Moving the mode select switch to Ing/start while the Eng Is running , Puts the Igniters into (Continuous Ignition)------------------------------------------------------------------------------------------------------------Solenoid Valves: located 3 O’clock R/H Fan (6 ea) – control respective Bleed Valve) a. pneumatic system / HP Valve Closure Solenoid b. Stage 7 – Bleed Solenoid Valve (A) c. Stage 7 – Bleed Solenoid Valve (B) d. Stage 7 – Bleed Solenoid Valve (C) e. Stage 10 – Bleed Solenoid Valve f. 10th Stage – Make-Up Air Solenoid Valve------------------------------------------------------------------------------------------------------------Bleed Valves: a. Stage 7 Bleed Valve – (1 O’clock) –(R/H core) b. Stage 10 Bleed Valve – (2 O’clock) – (R/H core) c. Stage 7b Bleed Valve – (3 O’clock) – (R/H core) d. Stage 7a & 7c Bleed Valve – (7 O’clock) – (L/H core) e. 10th Stage Make-Up Air Valve – (12 O’clock)Note: 7th stage bleed valve – bleeds off 5% of compressor airflow
10th stage bleed valve – bleeds off 9.7% of compressor airflow------------------------------------------------------------------------------------------------------------LPT and HPT Active Clearance Control Actuator – (4 O’clock) (R/H core) a. Ensures Blade Tip clearance of the (Turbine Blades)------------------------------------------------------------------------------------------------------------ACOC – Uses 12th stage bleed air – to cool the oil – (Bleed Air is vented overboard)
------------------------------------------------------------------------------------------------------------Pressure Raising & Shut Off Valve – Part of the FMU a. Isolates the Fuel Supply to the Fuel Nozzles (during engine start) b. Opens when the Fuel Pressure is (High Enough) for FMU Control-----------------------------------------------------------------------------------------------------------Engine Vib Monitoring Unit (EVMU) Monitors Eng Vibration Levels (N1 & N2)Note: 1 Unit = (.3 inch per second) ---Normal = 1.0 to 3.0
FOR TRAINING PURPOSE ONLYwww.amevoice.com
- 63 -
LP/HP – Fuel Pmp - The (LP /Inlet) side of the pump rec the Fuel from the A/C The Fuel Enters LP side then (the fuel) is routed to the FCOC And (some) fuel is tapped to the (IDG FCOC) The (main) fuel is routed to the FCOC----------------------------------------------------------------------------------------------------------IDG -FCOC – Fuel is (tapped) and sent to the (IDG FCOC) (to cool IDG oil)This tapped fuel is (sent) through the EEC and then Routed toThe (Fuel Diverter / Return Valve) and then returned to the Aircraft Fuel Tank.
----------------------------------------------------------------------------------------------------------Fuel Diverter / Return Valve – Installed on the FCOC--Controls the Return (Fuel) Flow back to the A/C tanks. (Thus cooling the fuel)Controlled (via) the EEC (depending on Eng Demands) For Oil / Fuel temperature ------------------------------------------------------------------------------------------------------------Fuel Cooled Oil Cooler (FCOC) – Located 9 O’clock position L/H Uses fuel to (cool engine oil) Has a (Drain Plug) to allow for (draining the Fuel) Fuel Filter & Fuel Filter (by-pass) valve (inside) the FCOC------------------------------------------------------------------------------------------------------------Fuel Filter – Located in the FCOC------------------------------------------------------------------------------------------------------------Fuel Filter (by-pass) Valve – Allows for fuel to (by-pass) the filter if it is clogged------------------------------------------------------------------------------------------------------------LP/HP – Fuel Pump – Fuel is (routed) to the HP (inlet) side of the pump and then routed To the FMU.Fuel Met Unit (FMU) – 1. Controls the Fuel Flow – (via) inputs from the EEC 2. Protects against Over Speed 3. Controls the Shut Off Valve4. (Fuel is tapped) to: Supply (HP) (Muscle Fuel) to Actuator a. Stator Vane Act -- b. Active Clearance Control Valve (ACC) (HP turbine) c. Active Clearance Control Valve (ACC) (LP turbine) d. ACOC (air modulating valve) e. Booster Stage Bleed Valve Actuator (Master) f. Booster stage Bleed Valve Actuator (Slave)
Note: All of the Actuators are controlled (via) the EEC (except)The BVA (slave) (the slave is controlled (via) the master
Note: This tapped fuel is sent through the EEC and routedTo the Fuel Diverter / Return Valve and returned To the A/C Fuel Tank
------------------------------------------------------------------------------------------------------------The (main) Fuel is then routed to the Fuel Flow MeterNote: Excess (fuel pressure) is released (via) the (By-Pass) Line from the FMUAnd routed through the EEC and then to the Fuel Diverter / Return Valve------------------------------------------------------------------------------------------------------------
FOR TRAINING PURPOSE ONLYwww.amevoice.com
- 64 -
Fuel Flow Meter – Located L/H Fan (7 O’clock) Position (under the FMU) Installed in the (fuel line) (between the FMU and Dist Valve) Provides Fuel Flow (Indication) to the ECAM (Fuel press drives an imp (which spins and gives the indication) The fuel is then routed to the Distribution Valve------------------------------------------------------------------------------------------------------------ Distrib Vlv- Lct R/H Fan 4 O’clock Position (Btn the Fuel FM and Fuel manifolds) Distributes an equal amount of fuel to (10) Fuel manifolds / 2 nozzles ea Allows for (2) Fuel manifolds to (store) some fuel @ engine shutdown To help supply the fuel @ next engine start. The fuel is then routed to the Fuel manifolds------------------------------------------------------------------------------------------------------------Fuel Manifolds – A total of 10 manifolds (each manifold supplies 2 fuel nozzles)------------------------------------------------------------------------------------------------------------Fuel Nozzles – A total of 20 fuel nozzles are installed – The fuel (mixes) with the air and then it is Sent to the Combustion Chamber------------------------------------------------------------------------------------------------------------ Note: For Engine Starting Problems: Use Aids Report #10 in (Manual Reports)
Run Problems: Use Aids Report #11 in Manual Reports
Engine Overview
VSV Actuator: Varies the angle of the I/L Guide Vanes and Stator Vanes to match the LPComp stage to the HP Comp stage. This changes the angle of the airflowAcross the comp blades. The VSV angle determines the compression neededFor all stages of engine power. Controlled by the (EEC) and (via) fuel Pressure from the (FMU)------------------------------------------------------------------------------------------------------------Booster Stage Bleed Valve: at low (LP) compressor speeds the booster provides more air than the HP Comp can utilize. The (BSBV) opens and bleeds off excess air to make the engine more stable. The air is bleed off into the fan discharge air stream. At higher (compressor) speeds the (BSBV) closes to allow all booster discharge (primary) air enters the HP Compressor.There are (2) valves (master and slave) connected together (fuel press) and are
FOR TRAINING PURPOSE ONLYwww.amevoice.com
- 65 -
Synchronized to move together. The (master) valve is (controlled) via the EEC. The valves close during T/O and cruise. The (slave) valve moves in relation to the (master) valve, to assist in the movement of the Ring------------------------------------------------------------------------------------------------------------
The HP Comp Bleed Valves: redirects a portion of the Bleed Air to the Fan Air Stream. For Engine stability. Mounted on the outside of the case.When the (piston) valve opens it vents the air from the compressor. The 7th stage has (3) Bleed valves and the 10th stage has (1).They are used during engine starting and transient conditions.The Bleed Valves are connected (via) a tube to the Bleed Valve Solenoid----Controlled by the Bleed Valve Solenoid Valve (Via) the EEC----Spring Loaded Open and held open by compressor (p3) bleed air----When the (p3) air is (vented) by the (Solenoid Valve) the Valve Closes And stops the (Bleed Air) from being released into the Fan Air Stream------------------------------------------------------------------------------------------------------------Bleed Valve (Solenoid Valve): each bleedvalve has its own (sol Valve). It is connected to the bleed valve by a tube, which transmits (p3) pressure to or from the bleed valve. Controlled by the (EEC)---When the (Solenoid) is energized the (service port) is connected to the (Vent) This (venting) keeps the valve closed.---When the (Solenoid) is (de-energized) the (service port) is connected to The engine supplied air (via) the tube (thus holding the valve) openOil Temp Indication:---Sensor located at the scavenge filter.---Hi-Oil-warn ind @ 155 deg C for 15 minutes---Lo-Oil warn ind @ -10 deg C (when eng is running above idle speed)---Ind flashes Green @ 156 deg C and turns amber @ 165 deg COil Pressure Indication:----Sensor located L/H fan case---Low Oil pressure warn @ 60 PSI---Ind flashes RED---Automatically (resets) when pressure is above 60 PSI
FOR TRAINING PURPOSE ONLYwww.amevoice.com
- 66 -
FOR TRAINING PURPOSE ONLYwww.amevoice.com
- 67 -
Auto Start: 1. Mode Selector – (to Ign/start) – (EEC powers up) 2. Master Switch – (to ON) –(Imed Pressure and Start Valve) – (opens) 3. N2 Increases: a. At 16% - (Ign turned ON) (either A or B) b. At 18% - (Fuel Flow) c. At 43% - (Start Valve Closes) & (Ign is turned OFF) d. Engines are (now @ Idle) 4. Mode Selector – (To Normal) after both engines are running.Note: Auto Start is Aborted @ 50 % N2 in case of failure.
2. Manual Start: 1. Mode Selector – (to Ign/Start) – (EEC powers up) 2. Eng Manual p/b Switch – (ON) – (start valve opens) 3. N2 Increases: a. At 18% - (Master Switch to ON) – (Both A & B Ignition & Fuel Flow) b. At 43% (Start Valve closes and Ign is turned off) 4. Engines are now @ Idle 5. Manual P/B Switch (To Off)
3. Dry Crank: (Ignition Not Available) a. Mode Select (to Crank) – (available on ground, only) – (EEC Powered) b. Manual Start p/b switch – (ON) - (start valve opens) c. Master Switch – (ON)
4. Wet Crank: a. Mode Select – (to Crank) – (EEC Powered) b. Manual Start p/b switch – (ON) – (start valve opens)
FOR TRAINING PURPOSE ONLYwww.amevoice.com
- 68 -
c. At 20% N2 – (Master Switch) – (ON) d. When Finished (Cranking) – Master switch (OFF) e. Continue cranking for (30 seconds) f. Manual Start p/b switch (Off)
FOR TRAINING PURPOSE ONLYwww.amevoice.com
- 69 -
FOR TRAINING PURPOSE ONLYwww.amevoice.com
- 70 -
FOR TRAINING PURPOSE ONLYwww.amevoice.com
- 71 -
FOR TRAINING PURPOSE ONLYwww.amevoice.com
- 72 -